Line Lights

advertisement
Line Lights
LND2 Series
Universal usage for line sensor applications
Affordable cost line light to be compatible with conventional florescent tube light.
Increased Brightness
Product Lineup
Brighter than previous models. The LED Lights provide bright
uniform illumination for line sensors at a low cost.
Lights are available with either red or white light. Models are
available with emitting surface lengths of 301, 603, 903, and
1,203 mm.
LND2 and LND Brightness Comparison (Red)
LND2 and LND Brightness Comparison (White)
Brightness Comparison
Brightness Comparison
Approx.
8x
higher
Approx.
2x
higher
LND2
x1
LND
LND
H Model A Model
Approx.
7x
higher
White
603 mm
x1
903 mm
LND
LND
H Model A Model
(Value for comparison)
Red/
LED color:
301 mm
Approx.
2x
higher
LND2
Emitting surface lengths
available in 100-mm increments.
1,203 mm
(Value for comparison)
*Comparison of light intensity between new and previous models (based on actual measured values).
*The values given here are for reference only. Results for individual Lights may vary.
*Brightness will vary based on the camera’s spectral sensitivity.
You can order custom lights with emitting surface lengths that
are multiples of 100 mm. You can also order blue or green
LEDs. For details, please contact a CCS sales representative.
The Ideal Solution to Replace
Fluorescent Lights
The long life of LEDs means that they will not burn out like
fluorescent lights. This eliminates the cost and work involved
in replacing fluorescent lights.
Life Comparison between Fluorescent
and LND (Red) Lights
Change in LED Light Intensity and
Replacement Work for Fluorescent Lights
Fluorescent
Lights
0
10,000
20,000
30,000
40,000
50,000 Hours
*Calculated value until the light output decreases to 50% at
a light intensity of 100% and an ambient temperature of 25Cº.
(The values are for reference only.)
*Based on an assumed fluorescent light life of 1,500 hours.
1
10
Fluorescent light
replacement period
40
(Number of fluorescent
light replacements)
LED
Fluorescent
lights
20
0
0
10,000
20,000
30,000
Standard Sizes
301 mm
Suitable for All Types of Line Sensor Inspections
LED
can be
manufactured
603 mm
*This comparison illustrates the change in LED light output
and fluorescent light replacement every 1,500 hours.
Examples of Line Light Images
Light
Lights with
Green LEDs
can be
manufactured
Custom Order Sizes
101, 201, 401, 503, 703, 803, 1,003, and 1,103 mm
Illumination Structure of the LND2 Series
Workpiece
Lights with
Blue LEDs
20
80
60
100-mm
increments.
You can illuminate a long line of diffused light by
passing the light from the LEDs through a
Diffuser Plate.
Camera
51
Relative light output (%)
100
LND2
Emitting surface
lengths available in
Scratch and Dent Inspections
for Motor Shafts
Foreign Matter Inspections
for Transparent Film
903 mm
1,203 mm
Direct Number : A direct number is a 7-digit number assigned to a CCS product. You can easily access the web page providing
information on any desired product by simply entering the direct number in the space provided on the CCS
website pages for machine vision. (Refer to the back cover of this brochure.)
Specifications
Model
LND2-
RD
LND2-
SW
Emitting surface lengths
Direct Number
1271
Red
LED color
White
24V DC
Input voltage
Peak emitted wavelength/
C.color temperature
Connectors
630 nm (typ.)
5,500K (typ.)
Emitting surface length of 301 or 603 mm: SM Connector (SMR-03V-B)
Emitting surface length of 903 or 1,203 mm: EL Connector (ELP-02V)
Polarity and signals
SM Connector: 1: Anode (+), 2: NC, 3: Cathode (−)
EL Connector: 1: Anode (+), 2: Cathode (−)
Natural air cooling
Cooling method
Operating environment
(for indoor use only)
Temperature: 0 to 40°C, Humidity: 20% to 85%RH (with no condensation)
Storage environment Temperature: −20 to 60°C, Humidity: 20% to 85%RH (with no condensation)
Aluminum alloy, POM, and PMMA (Diffuser)
Case material
*The peak emitted light wavelength of the Red Bar Lights is 630 nm. For a Sharp-cut Filter, use the optional R60 Sharp-cut Filter.
*Refer to page 103 for information on options.
(Unit: mm)
2. Emitting Surface Length: 903 or 1,203 mm
A
Model
7
(for mounting)
A+31: Overall length
A: Emitting surface
Two × two, 4.5-dia. holes
with 8-mm counterbore, depth: 4.5
7
A+17
(for mounting)
A+17
27.2
11
11
27.2
*Use a cable with an SM connector for the extension cable.
18
18
13.6
903
1,203
EL Connector
15
15.5
4.5
6.1
Two × two, 4.5-dia. holes with
8-mm counterbore, depth: 4.5
300
A: Emitting surface
15
15.5
SM Connector
A
Model
LND2-900
LND2-1200
301
603
6.1
A+31: Overall length
4.5
18.2 (emitting surface)
LND2-300
LND2-600
300
1. Emitting Surface Length: 301 or 603 mm
18.2 (emitting surface)
Dimension Diagrams
2×M5
(Same on
opposite side.)
13.6
*Use a cable with an EL connector for the extension cable.
2×M5
(Same on
opposite side.)
Specifications/Dimensions by Total Illumination Length
Model
LND2-300RD
LND2-300SW
LND2-600RD
LND2-600SW
LND2-900RD
LND2-900SW
LND2-1200RD
LND2-1200SW
Power
consumption(W)
Weight(g)
23
18
46
35
69
53
91
70
200
200
360
360
505
505
670
670
Dimensions
A: Emitting
Full length(mm)
surface(mm)
301
301
603
603
903
903
1,203
1,203
332
332
634
634
934
934
1,234
1,234
If you register as a CCS member, you can download all materials (such as PDF or DXF drawings and operation manuals) from our website. You can also request us to select the
appropriate Light Unit, borrowing demonstration units and to quote the product’s price. Please go ahead and register as a member today. (Refer to back cover of this brochure.)
52
Download