ACS-PCM2-5 POWER CONTROL MODULE FOR USE WITH RAYCHEM ACS-UIT2 INSTALLATION INSTRUCTIONS DESCRIPTION The ACS-PCM2-5 provides ground-fault and line current sensing, alarming, switching (electromechanical relays) and RTD inputs for five heat tracing circuits when used with the ACS-UIT2. The ACS-PCM2-5 enclosure is rated NEMA 4/12 and is approved for nonhazardous indoor and outdoor locations that are subject to freezing.These instructions describe how to mount the ACS-PCM2-5 and make the various power, communications, and RTD wiring connections. All electrical connections, maintenance and servicing must be done by a qualified electrician. If your application conditions are different, or if you have questions, please contact your Pentair Thermal Building Solutions representative or contact Pentair Thermal Building Solutions directly at (800) 545-6258. TOOLS REQUIRED • Drill to mount enclosure • Small flat-head screwdriver • Phillips (cross-head) screwdriver APPROVALS/CERTIFICATIONS Nonhazardous Locations ADDITIONAL MATERIALS REQUIRED UL STD 508A CAN/CSA C22.2 NO. 14 • RS-485 cable (Belden #8761 or Carol # C2514) • Wall fasteners for surface mounting (four screws) • ACS-30 Programming Guide (H58279) • ACS-UIT2 Installation Instruction (H58239) General Communication to ACS-UIT2 Ambient Operating Temp. –13°F to 122°F (–25°C to 50°C) Dimensions 24 in. W X 24 in. H X 6.75 in. D (610 mm W X 610 mm H X 171 mm D) Enclosure Rating NEMA 4/12 (Indoor/outdoor locations) Weight 70 lbs (31.75 kg) Humidity 0 – 90% non-condensing Fuse Bussman MDL Input 100 – 277 Vac (from Ch 1 to power control devices) Type Cable Length Quantity Control Contactors Rating 3-pole – 30 A/pole 277 V Max Type Sprecher-Schuh CA7-16-10-12D Quantity5 THERMAL BUILDING SOLUTIONS Max current Accuracy 60 A ± 2% of reading Ground-Fault Sensors Range Accuracy Type Power Supply/Line/Load #22 – 8 AWG RS-485 #24 – 12 AWG RTD #24 – 12 AWG FIRE HAZARD: Do not mount the ACS-PCM2-5 in a hazardous location. SHOCK HAZARD: Follow all local electrical safety procedures. Disconnect power before servicing or opening this unit. Line Current Sensors 10 – 200 mA ± 4% of range at 30 A line current Temperature Sensors Connection Terminals WARNING: 2 wire RS-485 One shielded twisted pair 4000 ft (1200 m) maximum Up to 52 ACS-PCM2-5 panels may be connected to one ACS-UIT2. Quantity 100-ohm platinum RTD, 3-wire, α = 0.00385 ohm/ohm/°C Can be extended with a 3-conductor shielded cable of 20 ohm maximum per conductor Up to five wired directly to each ACS-CRM IMPORTANT: The ACS-PCM2-5 is an electronic unit. During installation, take the following precautions to avoid damage to its electronic components. • Handle with care to avoid mechanical damage. • Keep electronics dry. • Avoid exposure to static electricity. • Avoid contamination with metal filings, liquids, or other foreign matter. EN-RaychemACSPCM25-IM-H58672 03/15 • Take care to protect the user interface board on the enclosure door. • Use agency-approved conduit bushings, adapters, and cable glands to keep the enclosure protected from dust and fluids. 1/8 Panel Layout ItemQty Description TB 17 TB 16 TB 15 TB 5 TB 4 TB 14 C3 TB 3 C2 TB 2 C1 TB 1 1 B 1NGC-30-CTM (current transfer module) C D E F 5 3-pole contactors 5 RTD Inputs 9 Status LEDs 1 120–277 Vac to 12 Vdc power supply G H I 1 Alarm relay 1 Dry alarm contacts 3 RS-485 (IN) terminal blocks J 3 RS-485 (OUT) terminal blocks K 5 Line in terminal blocks L 5 Load out terminal blocks M N 3 Power supply input 1 Grounding bar C5 TB 19 1 2 3 TB 6 C4 TB 13 A TB 12 TB 7 MSB LSB ACS-CRM (card rack module) ACS-PCM2-5 Terminal Block Layout Alarm Relay Alarm (factory wired) Dry Contacts Heater Power Input In Out NC Com NO NO Com NC – + Shld – 1 2 3 L1 L2/N Ground Bar Heating cable power in and out: 120-277 Vac THERMAL BUILDING SOLUTIONS 4 5 1 2 3 4 5 + Shld External device Front Panel Signal Light Power Supply Input Heater Power Output (factory wired) Heating Cable Power: 120–277 Vac RS-485 Communications EN-RaychemACSPCM25-IM-H58672 03/15 L1 L2 Heating cable Braid/Sheath Heating Cable Connection 2/8 Mounting the Enclosure The Raychem ACS-PCM2-5 controller must be mounted in a nonhazardous location. The panel is rated NEMA 4/12 with an ambient range of –13°F to 122°F (–25°C to 50°C). Heater Power Input and Ground (See schematic on Page 2) Heater Power Output and Ground (See schematic on Page 2) Heater Power Input K and Ground N 1. Locate the Heater Power Input (K) terminal block (No 1 – 10) and connect per the ACS-PCM2-5 Terminal Block Layout on page 2. Depending upon size and type of the remotely located branch circuit breakers*, use the appropriate size and number of wires from the circuit breaker to the Heater Power Input terminals. Heater Power Output J and Ground N 1. Locate the Ground Bus bar (N) and using the appropriate size wire, connect a ground wire from the ground bus bar to the heating cable’s power connection enclosure and terminate to the heating cable’s braid. Control Power 2. Locate the Ground Bus bar (N) and using the appropriate size wire, connect a common ground wire from the branch circuit breaker panel board. No additional voltage supply is required to power the internal ACS-CRM board, alarm light and contactors. Theses devices are powered from 100-277 Vac tapped from circuit 1 heating cable power input. If a dedicated input power supply is required contact Pentair Thermal Building Solutions for assistance. Note: 1. The ACS-PCM2-5 has integrated ground-fault circuit protection and therefore does not require additional ground-fault protection when connecting it to power. 2. Circuit breakers can be the following: Voltage # of poles Connection Maximum C.B. size *120 1 phase to neutral 30 A 208 2 phase to phase 30 A 240 2 phase to phase 30 A *277 1 phase to neutral 30 A *For 120 and 277 V, bring a separate neutral from each breaker THERMAL BUILDING SOLUTIONS EN-RaychemACSPCM25-IM-H58672 03/15 3/8 Connecting the RS-485 Device Network The ACS-UIT2 display is typically linked to a network of Raychem ACS-PCM2-5 power panels (incorporating the ACS-CRMs) and optional RMM2 devices. These are connected to the Raychem ACS-UIT2 using an RS-485 communication cable (shielded, two conductor, twisted pair). The following illustration shows how the RS-485 network for the ACS system can be configured. Device must be mounted in series. (Terminated devices are shown in gray) ACS-UIT2 Branching of the network is not allowed. Connect no more than two RS-485 cables to any device. RMM2 0 RMM2 0 ACS-PCM2-5 HEAT TRACE CONTROL PANEL ACS-UIT2 ACS-UIT2 DANGER MAXIMUM 277 VOLTS ACS-PCM2-5 MODEL NO: ACCS-PCM2-5 ENCLOSURE: TYPE 4, 12 sSERIAL NO: XXXXXXXX-XXXX VOLTAGE: MAX 277 VAC, 1PHASE, 2 WIRE, 60 HZ SHORT CIRCUIT CURRENT 5kA RMS SYMMETRICAL, 277 VAC MAZIMUM HEAT TRACE CONTROL PANEL ACS-PCM2-5 HEAT TRACE CONTROL PANEL DANGER MAXIMUM 277 VOLTS MODEL NO: ACCS-PCM2-5 ENCLOSURE: TYPE 4, 12 sSERIAL NO: XXXXXXXX-XXXX VOLTAGE: MAX 277 VAC, 1PHASE, 2 WIRE, 60 HZ SHORT CIRCUIT CURRENT 5kA RMS SYMMETRICAL, 277 VAC MAZIMUM DANGER MAXIMUM 277 VOLTS ACS-PCM2-5 MODEL NO: ACCS-PCM2-5 ENCLOSURE: TYPE 4, 12 sSERIAL NO: XXXXXXXX-XXXX VOLTAGE: MAX 277 VAC, 1PHASE, 2 WIRE, 60 HZ SHORT CIRCUIT CURRENT 5kA RMS SYMMETRICAL, 277 VAC MAZIMUM HEAT TRACE CONTROL PANEL RMM2 Jumper 0 DANGER MAXIMUM 277 VOLTS RMM2 Jumper MODEL NO: ACCS-PCM2-5 ENCLOSURE: TYPE 4, 12 sSERIAL NO: XXXXXXXX-XXXX VOLTAGE: MAX 277 VAC, 1PHASE, 2 WIRE, 60 HZ SHORT CIRCUIT CURRENT 5kA RMS SYMMETRICAL, 277 VAC MAZIMUM 0 ACS-PCM2-5 HEAT TRACE CONTROL PANEL DANGER MAXIMUM 277 VOLTS MODEL NO: ACCS-PCM2-5 ENCLOSURE: TYPE 4, 12 sSERIAL NO: XXXXXXXX-XXXX VOLTAGE: MAX 277 VAC, 1PHASE, 2 WIRE, 60 HZ SHORT CIRCUIT CURRENT 5kA RMS SYMMETRICAL, 277 VAC MAZIMUM In order for the RS-485 network to work properly, you must enable the termination resistor for the first and last device. The devices shown in gray in the illustration above represent the devices for which you must enable the termination resistors. The devices that are not grayed out represent the devices for which you should not enable the termination resistors. THERMAL BUILDING SOLUTIONS EN-RaychemACSPCM25-IM-H58672 03/15 4/8 Connection You must make an RS-485 connection from the ACS-UIT2 to the ACS-CRM board in the ACS-PCM2-5 panel. To make this connection, a pre-wired terminal block has been provided in the ACS-UIT2 (TB3- terminals 1, 2, and 3) and in the ACS-PCM2-5 panel (TB (H) and (I)). Connect the RS-485 wire from TB3 in the ACS-UIT2 and the other end to the TB (H) in the ACS-PCM2-5 panel maintaining the correct polarity. If the ACS-UIT2 or ACS-CRM is the first or last device in the RS-485 network, see below for details on how to terminate the RS485 network. ACS-PCM2-5 (Panel 1) ACS-UIT2 Input To downstream devices (ACS-PCM2-5, RMM2) + 5 – + – 4 3 2 1 5 4 3 2 1 T 9 8 7 6 T 9 8 7 6 RS-485 Field Port ACS-PCM2-5 (Panel 2) RS-485 RS-485 Output Input Output BMS gateway RS-485 Remote Port To next ACS-PCM-5 or RMM2 Termination of RS-485 Network (if First or Last in Network) ACS-UIT2 ACS-CRM A RS-485-2 Termination RS-485-1 Termination 3 2 1 MSB Pull-down Pull-up Termination 2 Position Switch On Off Comments Pull-down (As-shipped default) RS-485 network “–” signal is forced to a determinate state when idle. RS-485 network “–” signal is not forced to a determinate state when idle. One device (typically this ACS-UIT2) on the RS-485 network should force the network “–” signal to a determinate state. (As-shipped default) RS-485 network “+” signal is forced to a determinate state when idle. RS-485 network “+” signal is not forced to a determinate state when idle. One device (typically this ACS-UIT2) on the RS-485 network should force the network “+” signal to a determinate state. Termination (As-shipped RS-485 network default) RS-485 is not terminetwork is nated. terminated with 120-ohm resistor. Terminate the device (ACS-UIT2 or other) that is at each end of the RS-485 network, for a total of two terminated devices. No other devices on the network should be terminated. Pull-up LSB 1 ON THERMAL BUILDING SOLUTIONS 3 4 TB 12 TB 7 TB 1 TB 2 TB 3 TB 4 TB 5 TB 13 TB 14 TB 15 TB 16 TB 17 1 2 3 TB 19 TB 6 5 1 Address Switches 2 RTD Inputs (x5) 3 Alarm Output 6 4 Relay Outputs (x5) 5 Status LEDs 6 End of Line (EOL) jumper End of Line (EOL) Jumper 6 If this device (ACS-CRM) is the last device in the RS-485 network, the J1 jumper needs to bemoved from terminals 2 & 3 to terminals 1 & 2. EN-RaychemACSPCM25-IM-H58672 03/15 Normal position End of Line position 1 2 3 1 2 3 5/8 Optional RMM2 Installed in the Field Refer to the RMM2 Installation Instructions (H56848) for field installation instructions. You must connect an RS-485 cable from the RMM2 to the Raychem ACS-PCM2-5 panel. To make this connection, a pre-wired terminal block has been provided in the Raychem ACS-PCM2-5 panel. Connect the RS-485 wire from the RMM2 to the RS-485 terminal block (either H or I) while maintaining the correct polarity as shown below. If the RMM2 is the first or last device in the RS-485 network, connect the J17 termination jumper to pins 1 and 2. If the RMM2 is not the first or last device in the RS-485 network, connect the J17 termination jumper to pins 2 and 3. Connecting RTD Sensors - As Required RTD Inputs 2 3-wire RTDs with shield may be connected to RTD Ch1 thru Ch5 (TB1 – TB5). The two common wires (usually red, red) are connected to terminals 2 & 3, the source (usually white) to terminal 1 and the braid to terminal 4 (earth ground). 4 3 2 1 per each ACS-CRM board RTD connected directly to the CRM board Chassis Ground Shield CH5 – RTD5 Terminal Number Red Red White RTD 4 3 2 1 RTD 4 3 2 1 RTD 4 3 2 1 RTD 4 3 2 1 RTD 4 3 2 1 Shield CH4 – RTD4 CRM PCB Shield CH3 – RTD3 Shield CH2 – RTD2 Last RMM2 in network Shield CH1 – RTD1 Default position (for all RMM2 units in network except first or last one) Termination mode (first or last RMM2 in network) Connecting External Device Input (Snow Controller, Override Device) The RMM2 uses address range 32 – 47. Refer to the RMM2 Heat Tracing Remote Monitoring Module Installation Instruction (H56848) for setting address switch. Setting Address Switches on CRM Board Connect 2-wire shielded cable from the normally open position of the external device dry contacts to the RTD input terminals on the ACS-CRM Board. Connect the cable to terminals 1 and 3 with a jumper between position 2 and 3 as shown below: Address Switches (SW1 & SW2) 1 THERMAL BUILDING SOLUTIONS ACS-PCM2-5 Chassis Ground LSB 8 MSB External Device or Snow Controller (Dry Contact) SW2 SW1 ACS-CRM Board RTD Input 3 Each ACS-CRM must have a unique communication address. The valid address switch range for the ACS-UIT2 is 1–99. SW1 is the ones digit (0–9) and SW2 is the tens digit (0–9). Note: When adding an ACS-CRM to the system, you must first cycle power on the CRM board and then perform a network update at the ACS-UIT2. EN-RaychemACSPCM25-IM-H58672 03/15 Ground 4 3 2 Jumper No 1 6/8 Communications and Function Status LEDs Status LEDs 5 A cluster of 9 LED's are positioned on the CRM board which present the status of the circuit in the ACS-PCM2-5 panel. MSB LSB 1 2 Relay 5 (red) TB 1 3 4 TB 12 TB 7 TB 2 TB 3 TB 4 TB 5 Rx (yellow) 1 2 3 TB 19 Tx (yellow) TB 6 TB 13 5 TB 14 TB 15 TB 16 TB 17 6 Relay 4 (red) Relay 3 (red) 1 Address Switches 2 RTD Inputs (x5) 3 Alarm Output 4 Relay Outputs (x5) 5 Status LEDs 6 End of Line (EOL) jumper Relay 2 (red) Relay 1 (red) Alarm (red) Power (green) The following table summarizes the Status LEDs: Function Color Description Power Green Indicates power is supplied to the ACSCRM board. Alarm Red Indicates that the ACS-CRM board registered an alarm condition. Check the ACSUIT2 screen for events log to determine the alarm condition and to re-set the boards. Relay 1-5 Red Indicates that the heating cable relay is energized. Rx Yellow Flickering indicates data reception Tx Yellow Flickering indicates data transmission THERMAL BUILDING SOLUTIONS EN-RaychemACSPCM25-IM-H58672 03/15 7/8 WWW.PENTAIRTHERMAL.COM NORTH AMERICA EUROPE, MIDDLE EAST, AFRICA ASIA PACIFIC LATIN AMERICA Tel:+1.800.545.6258 Fax:+1.800.527.5703 Tel:+1.650.216.1526 Fax:+1.650.474.7215 thermal.info@pentair.com Tel:+32.16.213.511 Fax:+32.16.213.603 thermal.info@pentair.com Tel:+86.21.2412.1688 Fax:+86.21.5426.2937 cn.thermal.info@pentair.com Tel.:+1.713.868.4800 Fax:+1.713.868.2333 thermal.info@pentair.com Pentair is owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. © 2010-2014 Pentair. THERMAL BUILDING SOLUTIONS EN-RaychemACSPCM25-IM-H58672 03/15 8/8