BEZEL COMPATIBILITY KEY TRACJACK® CONFIGURATION WIREMOLD BEZEL PART NO. NUMBER OF JACKS 1 MAB6TJ 2 AB2TJ-xx + + = = TRACKJACK TRACKJACK DESCRIPTION Accepts (6) TracJack jacks Mounts up to (6) TracJack modules, modules are front-loaded Accepts (2) TracJack jacks Mounts up to (2) TracJack modules, modules are front-loaded Notes: Blanking panels are available. Use part number OR-42100002-xx. “xx” denotes color options. See catalog for detailed ordering information. TECHCHOICE® WIREMOLD BEZEL PART NO. BEZEL 2 PART NO. 3 CM-MAB-xx 4 CM-2AB-xx + + OR + + CM2-U1KEYA-xx or CM2-U2KEYA-xx TECHCHOICE OR CM2-U1KEYA-xx or CM2-U2KEYA-xx TECHCHOICE NUMBER OF JACKS = = DESCRIPTION Accepts (3–6) TechChoice jacks depending on bezel 2 selected Mounts up to (6) TechChoice modules, modules are rear-loaded Accepts (1–2) TechChoice jacks depending on bezel 2 selected Mounts up to (2) TechChoice modules, modules are rear-loaded ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE CONFIGURATION Notes: Blanking panels are available. Use part number OR-KSB10-xx. “xx” denotes color options. See catalog for detailed ordering information. 1 BEZEL COMPATIBILITY KEY SERIES II® CONFIGURATION WIREMOLD BEZEL PART NO. 5 MAB3S2-xx 6 ABS2-xx + + SERIES II SERIES II = = NUMBER OF JACKS DESCRIPTION Accepts (3) Series II jacks Mounts up to (3) Series II modules, modules are front-loaded Accepts (1) Series II jack Mounts up to (2) TechChoice modules, modules are rear-loaded ADDITIONAL OPTIONS DESCRIPTION PART NO. Mounts TechChoice modules in a Series II style opening OR-KSS2210 DESCRIPTION Mounts HDJ modules in a TrackJack style opening ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE PART NO. OR-HDJTJA Notes: Blanking panels are available. Use part number OR-40300164-xx. “xx” denotes color options. See catalog for detailed ordering information. TYPICAL INSTALLATION FOR TRACJACK AND SERIES II TYPICAL INSTALLATION FOR TECHCHOICE 1. Pull cables through unloaded bezel 1. Pull cable through unloaded bezel 2. Terminate or attach cables to module per manufacturers instructions 2. Snap bezel in to the front of the adapter plate 3. Snap module in to the front of the bezel 3. Terminate or attach cables to module per manufacturers instructions 4. Snap the bezel in to the front of the adapter plate 4. Snap module in to the back of CM2-UxKEYA-xx insert Notes: Steps 2 and 3 are interchangeable per installers preference. 5. Snap insert in to the front of the bezel 2 FLOOR BOXES PART NO. NEEDED EFB6S Installation Considerations Conduit Size: .75”–1.25” Capacity: 6-gangs Depth behind plate: 3.75” EFB8S Installation Considerations Conduit Size: .75”–2” Capacity: 8-gangs Depth behind plate: 3.5” DESCRIPTION HDJ PART NO. NEEDED TracJack faceplates OR-403005xx PART NO. NEEDED OR-403HDJxx OR-KSxxx PART NO. NEEDED OR-KSxxx DESCRIPTION Series II faceplates OR-40300xxx TechChoice faceplates HDJ faceplates OR-403HDJxx DESCRIPTION SERIES II® TechChoice faceplates HDJ faceplates TracJack faceplates OR-403005xx DESCRIPTION TECHCHOICE® Series II faceplates ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE TRACJACK® OR-40300xxx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 3 FLOOR BOXES TRACJACK® EFB10-2C – TECHCHOICE® – AB2TJ-xx EFB10-6AB SERIES II® Device plate mounts up to (6) TechChoice modules (accepts configuration 3, CM2-U2KEYA-xx sold separately) Mounts up to (3) Series II modules EFB10-3S2 CM2-U2KEYA-xx Mounts up to (4) TracJack modules – – EFB10-2C 55074TJ-WH Device plate mounts up to (6) TechChoice modules (accepts configuration 3, CM2-U2KEYA-xx sold separately) CM2-U2KEYA-xx Mounts up to (6) TracJack modules – – – EFB10-2C Device plate mounts (1) Series II module (accepts configuration 6, ABS2 bezel sold separately) ABS2-xx – – ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE EFB10S Installation Considerations Conduit Size: .75”–2” Capacity: 10-gangs Depth behind plate: 3.5” Device plate mounts up to (2) TracJack modules (accepts configuration 2, AB2TJ bezel sold separately) HDJ – 55076TJ-WH Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 4 FLOOR BOXES TRACJACK® DESCRIPTION RFB2RT Internal communication bracket mounts up to (4) TrackJack devices (accepts configuration 2, all parts included) RFB2GFI Internal GFI or Decorator style receptacle bracket accepts standard GFCI or Decorator style receptacles, communication or A/V devices and TracJack frame PART NO. NEEDED – – TECHCHOICE® DESCRIPTION RFB-GFI OR-419000 DESCRIPTION RFB22AB Internal communication bracket mounts up to (4) TechChoice devices (accepts configuration 4, all parts included) – – OR-419000 RFB4 Installation Considerations Conduit Size: .75”–1.25” Capacity: 4-gangs Depth behind plate: 2” PART NO. NEEDED RFB2GFI Internal GFI or Decorator style receptacle bracket cccepts standard GFCI or Decorator style receptacles, communication or A/V devices, and TechChoice frame SERIES II® PART NO. NEEDED DESCRIPTION Internal communication bracket mounts (2) Series II devices (accepts configuration 6, all parts included) RFB2RT – – OR-KSDS4 Internal GFI bracket accepts standard GFCI or Decorator style receptacles, communication or A/V devices, and TracJack stylistic frame – – RFB4-LPB Communication bracket mounts up to (6) TechChoice devices (accepts configuration 3, CM2-UxKEYA-xx inserts sold separately) RFB4-LPBS2 Communication bracket mounts up to (3) Series II devices (accepts configuration 5, all parts included) CM2-U2KEYA-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 5 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE RFB2 Installation Considerations Conduit Size: .75”–1.25” Capacity: 2-gangs Depth behind plate: 3” PART NO. NEEDED HDJ FLOOR BOXES TRACJACK® RFB4 Installation Considerations Conduit Size: .75”–1.25” Capacity: 4-gangs Depth behind plate: 2” DTB-2-DECORA DESCRIPTION Communication bracket Decorator style opening for Decorator style 106 adapter, and TracJack 106-type frame PART NO. NEEDED – TECHCHOICE® DESCRIPTION – OR-419000 – PART NO. NEEDED DTB-2-2AB Communication bracket mounts up to (6) TechChoice devices (accepts configuration 3, CM2-UxKEYA-xx inserts sold separately) PART NO. NEEDED DTB-2-2RT DESCRIPTION Communication bracket mounts (2) Series II devices (accepts configuration 6, all parts included) CM2-U2KEYA-xx – – – DTB-2-4TKO DTB-2-2RT DESCRIPTION SERIES II® Communication bracket mounts (4) TracJack devices (accepts configuration 2, all parts included) – – WTB-2-AB Communication bracket (4) RJ keystone opening knockouts, use as blank plate or for up to (4) RJ openings Communication bracket mounts up to (6) TechChoice devices (accepts configuration 3, CM2-UxKEYA-xx inserts sold separately) WTB-2-RT – Communication bracket mounts (1) Series II device (accepts configuration 6, all parts included) ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE PART NO. NEEDED HDJ – CM2-U2KEYA-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 6 FLOOR BOXES TRACJACK® PART NO. NEEDED RFB4 Installation Considerations Conduit Size: .75”–1.25” Capacity: 4-gangs Depth behind plate: 2” – HDJ DESCRIPTION – PART NO. NEEDED – TECHCHOICE® DESCRIPTION – PART NO. NEEDED RFB-GFI DESCRIPTION SERIES II® PART NO. NEEDED DESCRIPTION Internal GFI bracket accepts standard GFCI or Decorator style receptacles, communication or A/V devices, and TechChoice stylistic frame – – Communication bracket Decorator style opening for Decorator style 106 adapter and TechChoice stylistic frame and TechChoice 106-type frame – – Communication bracket with duplex opening for use with 106 adapter, sold separately, devices not included, and TechChoice 106-type frame – – OR-KSDS4 – – – – DTB-2-DECORA – – – – DTB-2-SD ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE OR-KSDS4 OR-KS106S2 Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 7 FLOOR BOXES TRACJACK® RFB4E Installation Considerations Conduit Size: .75”–2” Capacity: 4-gangs Depth behind plate: 3.5” RFB6RT RFB6GFI DESCRIPTION Internal communication bracket mounts up to (4) TrackJack devices (accepts configuration 2, all parts included) Internal GFI or Decorator style receptacle bracket accepts standard GFCI and Decorator style receptacles, communication or A/V devices, and TracJack stylistic frame PART NO. NEEDED – TECHCHOICE® DESCRIPTION – CM2-U2KEYA-xx – – OR-419000 RFB6 RFB6E Installation Considerations Conduit Size: .75”–1.25” Capacity: 6-gangs Depth behind plate: 3.25” RFB6RT PART NO. NEEDED RFB6GFI DESCRIPTION Internal communication bracket mounts up to (4) TechChoice devices (accepts configuration 4, CM2-UxKEYA-xx inserts sold separately) SERIES II® PART NO. NEEDED DESCRIPTION RFB6RT Internal communication bracket mounts (2) Series II devices (accepts configuration 6, all parts included) Internal GFI or Decorator style receptacle bracket accepts standard GFCI and Decorator style receptacles, communication or A/V devices, and TechChoice stylistic frame – – OR-KSDS4 Internal communication bracket mounts up to (4) TrackJack devices (accepts configuration 2, all parts included) – – CM2-U2KEYA-xx Internal communication bracket mounts up to (4) TechChoice devices (accepts configuration 4, CM2-UxKEYA-xx inserts sold separately) RFB6RT Internal communication bracket mounts (2) Series II devices (accepts configuration 6, all parts included) Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 8 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE PART NO. NEEDED HDJ FLOOR BOXES TRACJACK® RFB6 RFB6GFI RFB6E Installation Considerations Conduit Size: .75”–1.25” Capacity: 6-gangs Depth behind plate: 3.25” Internal GFI or Decorator style receptacle bracket accepts standard GFCI and Decorator style receptacles, communication or A/V devices, and TracJack stylistic frame PART NO. NEEDED – DESCRIPTION – OR-419000 RFB9 Installation Considerations Conduit Size: .75”–2” Capacity: 9-gangs Depth behind plate: 2.5” RFB119-2SRT RFB11 Installation Considerations Conduit Size: .75”–2” Capacity: 11-gangs Depth behind plate: 2.5” DESCRIPTION TECHCHOICE® PART NO. NEEDED RFB6GFI DESCRIPTION Internal GFI or Decorator style receptacle bracket accepts standard GFCI and Decorator style receptacles, communication or A/V devices, and TechChoice stylistic frame SERIES II® PART NO. NEEDED – DESCRIPTION – OR-KSDS4 Communication device plate mounts up to (6) TracJack devices in a 2-gang sectional width footprint (accepts configuration 1, all parts included) – – RFB119-2SAB Communication device plate mounts up to (6) TechChoice devices in a 2-gang sectional width footprint (accepts configuration 3, CM2-UxKEYA-xx inserts sold separately) RFB119-2SRT Communication device plate mounts up to (3) Series II devices in a 2-gang sectional width footprint (accepts configuration 5, all parts included) CM2-U2KEYA-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 9 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE PART NO. NEEDED HDJ FLOOR BOXES TRACJACK® PART NO. NEEDED RFB9 Installation Considerations Conduit Size: .75”–2” Capacity: 9-gangs Depth behind plate: 2.5” RFB119-RT DESCRIPTION Communication device plate mounts up to (6) TracJack devices in a standard width footprint (accepts configuration 1, all parts included) HDJ PART NO. NEEDED – TECHCHOICE® DESCRIPTION – RFB11 Installation Considerations Conduit Size: .75”–2” Capacity: 11-gangs Depth behind plate: 2.5” 880W Installation Considerations Conduit Size: .5”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” RFB119-AB DESCRIPTION Communication device plate mounts up to (6) TechChoice devices in a standard width footprint (accepts configuration 3, CM2-UxKEYA-xx inserts sold separately) PART NO. NEEDED RFB119-RT DESCRIPTION Communication device plate mounts up to (3) Series II devices in a 2-gang sectional width footprint (accepts configuration 5, all parts included) CM2-U2KEYA-xx 817B 1-gang brass combination carpet and tile flange mounts up to (6) TracJack devices (accepts configuration 1, MAB6TJ bezel sold separately) 817B – – CM-MAB-xx MAB6TJ 1-gang brass combination carpet and tile flange mounts up to (6) TechChoice devices (accepts configuration 3, CM-MAB-xx bezel and CM2-UxKEYA-xx inserts sold separately) 817B 1-gang brass combination carpet and tile flange mounts up to (3) Series II devices (accepts configuration 5, MAB3S2 bezel sold separately) MAB3S2 CM2-U2KEYA-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 10 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE OMNIBOX Installation Considerations Conduit Size: .25”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” PART NO. NEEDED SERIES II® FLOOR BOXES TRACJACK® PART NO. NEEDED 880W Installation Considerations Conduit Size: .5”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” 827B 2-gang brass combination carpet and tile flange mounts up to (12) TracJack devices (accepts configuration 1, MAB6TJ bezel sold separately) PART NO. NEEDED TECHCHOICE® DESCRIPTION PART NO. NEEDED 827B – – CM-MAB-xx MAB6TJ DESCRIPTION 2-gang brass combination carpet and tile flange accepts CM series inserts, sold separately, CM bezel, and CM2 module SERIES II® PART NO. NEEDED 827B DESCRIPTION 2-gang brass combination carpet and tile flange mounts up to (6) Series II devices (accepts configuration 5, MAB3S2 bezel sold separately) MAB3S2 CM2-U2KEYA-xx 837B 3-gang brass combination carpet and tile flange mounts up to (18) TracJack devices (accepts configuration 1, MAB6TJ bezel sold separately) 837B – – CM-MAB-xx MAB6TJ 3-gang brass combination carpet and tile flange mounts up to (18) TechChoice 837B devices (accepts configuration 3, CM-MAB-xx bezel and CM2-UxKEYA-xx inserts sold separately) 3-gang brass combination carpet and tile flange mounts up to (9) Series II devices (accepts configuration 5, MAB3S2 bezel sold separately) MAB3S2 CM2-U2KEYA-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 11 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE OMNIBOX Installation Considerations Conduit Size: .25”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” DESCRIPTION HDJ FLOOR BOXES TRACJACK® PART NO. NEEDED 880W Installation Considerations Conduit Size: .5”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” 818TCAL 1-gang aluminum combination carpet and tile flange mounts up to (6) TracJack devices (accepts configuration 1, MAB6TJ bezel sold separately) PART NO. NEEDED TECHCHOICE® DESCRIPTION PART NO. NEEDED 818TCAL – – CM-MAB-xx MAB6TJ DESCRIPTION SERIES II® PART NO. NEEDED 1-gang aluminum combination carpet and tile flange mounts up to (6) TechChoice 818TCAL devices (accepts configuration 3, CM-MAB-xx bezel and CM2-UxKEYA-xx inserts sold separately) DESCRIPTION 1-gang aluminum combination carpet and tile flange mounts up to (3) Series II devices (accepts configuration 5, MAB3S2 bezel sold separately) MAB3S2 CM2-U2KEYA-xx 828TCAL 2-gang aluminum combination carpet and tile flange mounts up to (12) TracJack devices (accepts configuration 1, MAB6TJ bezel old separately) 828TCAL – – CM-MAB-xx MAB6TJ 2-gang aluminum combination carpet and tile flange mounts up to (12) TechChoice 828TCAL devices (accepts configuration 3, CM-MAB-xx bezel and CM2-UxKEYA-xx inserts sold separately) 2-gang aluminum combination carpet and tile flange mounts up to (6) Series II devices (accepts configuration 5, MAB3S2 bezel sold separately) MAB3S2 CM2-U2KEYA-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 12 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE OMNIBOX Installation Considerations Conduit Size: .25”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” DESCRIPTION HDJ FLOOR BOXES TRACJACK® PART NO. NEEDED 880W Installation Considerations Conduit Size: .5”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” 838TCAL 3-gang aluminum combination carpet and tile flange mounts up to (18) TracJack devices (accepts configuration 1, MAB6TJ bezel sold separately) PART NO. NEEDED TECHCHOICE® DESCRIPTION PART NO. NEEDED 838TCAL – – CM-MAB-xx DESCRIPTION SERIES II® PART NO. NEEDED 3-gang aluminum combination carpet and tile flange mounts up to (18) TechChoice 838TCAL devices (accepts configuration 3, CM-MAB-xx bezel and CM2-UxKEYA-xx inserts sold separately) MAB6TJ DESCRIPTION 3-gang aluminum combination carpet and tile flange mounts up to (9) Series II devices (accepts configuration 5, MAB3S2 bezel sold separately) MAB3S2 CM2-U2KEYA-xx 817TCAL 1-gang powder-coated aluminum combination carpet and tile flange mounts up to (6) TracJack devices (accepts configuration 1, MAB6TJ bezel sold separately) 817TCAL – – CM-MAB-xx MAB6TJ 1-gang powder-coated aluminum combination carpet and tile flange mounts up to (6) TechChoice devices (accepts configuration 3, CM-MAB-xx bezel and CM2-UxKEYA-xx inserts sold separately) 817TCAL 1-gang powder-coated aluminum combination carpet and tile flange mounts up to (3) Series II devices (accepts configuration 5, MAB3S2 bezel sold separately) MAB3S2 CM2-U2KEYA-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 13 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE OMNIBOX Installation Considerations Conduit Size: .25”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” DESCRIPTION HDJ FLOOR BOXES TRACJACK® PART NO. NEEDED 880W Installation Considerations Conduit Size: .5”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” 827TCAL 2-gang powder-coated aluminum combination carpet and tile flange mounts up to (12) TracJack devices (accepts configuration 1, MAB6TJ bezel sold separately) PART NO. NEEDED TECHCHOICE® DESCRIPTION PART NO. NEEDED 827TCAL – – CM-MAB-xx MAB6TJ DESCRIPTION SERIES II® PART NO. NEEDED DESCRIPTION 2-gang powder-coated aluminum combination carpet and tile flange mounts up 827TCAL to (12) TechChoice devices (accepts configuration 3, CM-MAB-xx bezel and CM2-UxKEYA-xx inserts sold separately) MAB3S2 1-gang aluminum combination carpet and tile flange mounts up to (3) Series II devices (accepts configuration 5, MAB3S2 bezel sold separately) 2-gang aluminum combination carpet and tile flange mounts up to (12) TechChoice devices (accepts configuration 3, CM-MAB-xx bezel and CM2-UxKEYA-xx inserts sold separately) 2-gang aluminum combination carpet and tile flange mounts up to (6) Series II devices (accepts configuration 5, MAB3S2 bezel sold separately) CM2-U2KEYA-xx 837TCAL 3-gang powder-coated aluminum combination carpet and tile flange mounts up to (18) TracJack devices (accepts configuration 1, MAB6TJ bezel sold separately) 837TCAL – – CM-MAB-xx MAB6TJ 837TCAL MAB3S2 CM2-U2KEYA-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 14 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE OMNIBOX Installation Considerations Conduit Size: .25”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” DESCRIPTION HDJ FLOOR BOXES TRACJACK® PART NO. NEEDED OMNIBOX Installation Considerations Conduit Size: .25”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” 880W Installation Considerations Conduit Size: .5”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” DESCRIPTION HDJ PART NO. NEEDED TECHCHOICE® DESCRIPTION PART NO. NEEDED 817PCC-BLK 817PCC-BLK 829PFLRT 1-gang non-metallic carpet flange mounts up to (6) TracJack devices, use with 829PFLRT cover (accepts configuration 1, MAB6TJ bezel included with 829PFLRT cover, sold separately) – – 829PFL CM2-U2KEYA-xx DESCRIPTION 1-gang nonmetallic carpet flange mounts up to (6) TechChoice devices, use with 829PFL cover (accepts configuration 3, CM-MAB-xx bezel included with 829PFL cover, sold separately, CM2UxKEYA-xx inserts sold separately) SERIES II® PART NO. NEEDED 817PCC-BLK 829PFLRT DESCRIPTION 1-gang nonmetallic carpet flange mounts up to (3) Series II devices, use with 829PFLRT cover (accepts configuration 1, MAB3S2 bezel included with 829PFLRT cover, sold separately) MAB3S2 MAB6TJ ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE CM-MAB-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 15 FLOOR BOXES TRACJACK® PART NO. NEEDED OMNIBOX Installation Considerations Conduit Size: .25”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” 880W Installation Considerations Conduit Size: .5”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” 827PCC-BLK 829PFLRT DESCRIPTION 2-gang nonmetallic carpet flange mounts up to (12) TracJack devices, use with 829PFLRT covers (accepts configuration 1, MAB6TJ bezel included with 829PFLRT covers, sold separately) HDJ PART NO. NEEDED – TECHCHOICE® DESCRIPTION – PART NO. NEEDED DESCRIPTION 827PCC-BLK 2-gang nonmetallic carpet flange mounts up to (12) TechChoice devices, use with 829PFL covers (accepts configuration 3, CM-MAB-xx bezel included with 829PFL covers, sold separately, CM2-UxKEYA-xx inserts sold separately) 829PFL CM2-U2KEYA-xx MAB6TJ SERIES II® PART NO. NEEDED 827PCC-BLK 829PFLRT DESCRIPTION 2-gang nonmetallic carpet flange mounts up to (6) Series II devices, use with 829PFLRT covers (accepts configuration 1, MAB3S2 bezel included with 829PFLRT covers, sold separately) MAB3S2 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE CM-MAB-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 16 FLOOR BOXES TRACJACK® PART NO. NEEDED 880W Installation Considerations Conduit Size: .5”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” PART NO. NEEDED TECHCHOICE® DESCRIPTION PART NO. NEEDED DESCRIPTION SERIES II® PART NO. NEEDED DESCRIPTION 837PCC-BLK 837PCC-BLK 829PFLRT 3-gang nonmetallic carpet flange mounts up to (18) TracJack devices, use with 829PFLRT covers (accepts configuration 1, MAB6TJ bezel sold separately) – – 829PFL CM2-U2KEYA-xx 3-gang nonmetallic carpet flange 837PCC-BLK mounts up to (18) TechChoice devices, use with 829PFL covers (accepts configuration 3, 829PFLRT CM-MAB-xx bezel and CM2-UxKEYA-xx inserts sold separately) MAB6TJ 3-gang nonmetallic carpet flange mounts up to (9) Series II devices, use with 829PFLRT covers (accepts configuration 5, MAB3S2 bezel sold separately) MAB3S2 CM-MAB-xx RATCHET-PRO Installation Considerations Conduit Size: 1” Capacity: 1-gang Depth behind plate: 1.75” RPAV3CTCxx Multiple service cover kit includes (1) prewired 20A duplex receptacle, flange and slide holder, adapter ring, divider and bezel to mount (2) TracJack modules (accepts configuration 2, all parts included) – – RPAV3CTCxx Multiple service cover kit includes (1) prewired 20A duplex receptacle, flange and slide holder, adapter ring, divider and bezel to mount (1) CM2-UxKEYA-xx insert (accepts configuration 4, all parts included) RPAV3CTCxx Multiple service cover kit includes (1) prewired 20A duplex receptacle, flange and slide holder, adapter ring, divider and bezel to mount (1) Series II module (accepts configuration 6, all parts included) Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 17 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE OMNIBOX Installation Considerations Conduit Size: .25”–.75” Capacity: 1,2, or 3-gangs Depth behind plate: 2.75” DESCRIPTION HDJ FLOOR BOXES PART NO. NEEDED RATCHET-PRO Installation Considerations Conduit Size: 1” Capacity: 1-gang Depth behind plate: 1.75” RP4CTCxx RP7CTCxx DESCRIPTION Multiple service cover kit for RPSFB, RFSFB-OG, and RPNFB floor boxes includes (2) prewired 20A duplex receptacles, flange and slide holder, adapter ring, divider and bezels to mount TracJack modules (accepts configuration 2, all parts included) Multiple service cover kit includes (1) prewired 20A duplex receptacle, flange and slide holder, adapter ring, divider and bezel to mount TracJack modules (accepts configuration 2, all parts included) HDJ PART NO. NEEDED – TECHCHOICE® DESCRIPTION PART NO. NEEDED – RP4CTCxx – – RP7CTCxx DESCRIPTION Multiple service cover kit for RPSFB, and RPNFB RFSFB-OG, floor boxes includes (2) prewired 20A duplex receptacles, flange and slide holder, adapter ring, divider and bezels to mount CM2-UxKEYA-xx inserts (accepts configuration 4, all parts included) Multiple service cover kit includes (1) prewired 20A duplex receptacle, flange and slide holder, adapter ring, divider and bezels to mount CM2-UxKEYA-xx inserts (accepts configuration 4, all parts included) SERIES II® PART NO. NEEDED RP4CTCxx RP7CTCxx DESCRIPTION Multiple service cover kit for RPSFB, RFSFB-OG, and RPNFB floor boxes includes (2) prewired 20A duplex receptacles, flange and slide holder, adapter ring, divider and bezels to mount Series II modules (accepts configuration 6, all parts included) Multiple service cover kit includes (1) prewired 20A duplex receptacle, flange and slide holder, adapter ring, divider and bezels to mount Series II modules (accepts configuration 6, all parts included) Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 18 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE TRACJACK® FLOOR BOXES PART NO. NEEDED RATCHET-PRO Installation Considerations Conduit Size: 1” Capacity: 1-gang Depth behind plate: 1.75” RPAMD4CTCxx RPAMD8CTCxx AF1 Installation Considerations Conduit Size: .5” Capacity: Single or double-gang Depth behind plate: 2.75” with back plate installed DGT-RT DESCRIPTION Single service floor box cover kit with adapter ring and bezels to mount (4) TracJack modules (accepts configuration 2, all parts included) Single service floor box cover kit with adapter ring and bezels to mount TracJack modules (accepts configuration 2, all parts included) Double-gang plate for center compartment mounts up to (6) TracJack modules (accepts configuration 1, all parts included) HDJ PART NO. NEEDED – TECHCHOICE® DESCRIPTION PART NO. NEEDED – RPAMD4CTCxx – – RPAMD8CTCxx – – SGT-ACT DESCRIPTION Single service floor box cover kit with adapter ring and bezels to mount (4) TechChoice modules (accepts configuration 4, all parts included) Single service floor box cover kit with adapter ring and bezels to mount TechChoice modules (accepts configuration 4, all parts included) SERIES II® PART NO. NEEDED RPAMD4CTCxx RPAMD8CTCxx Single-gang plate accepts (3) 2A ActivateTM inserts, and CM2 module DESCRIPTION Single service floor box cover kit with adapter ring and bezels to mount (2) Series II modules (accepts configuration 6, all parts included) Single service floor box cover kit with adapter ring and bezels to mount Series II modules (accepts configuration 6, all parts included) Single-gang plate accepts (3) Series II inserts (upper compartment) SGT-3S2 CM2-U2KEYA-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 19 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE TRACJACK® FLOOR BOXES TRACJACK® PART NO. NEEDED AF1 Installation Considerations Conduit Size: .5” Capacity: Single or double-gang Depth behind plate: 2.75” with back plate installed HDJ DESCRIPTION Single-gang plate accepts (3) TracJack inserts, (upper compartment) PART NO. NEEDED – TECHCHOICE® DESCRIPTION – PART NO. NEEDED DGT-ACT SGT-3TJ DESCRIPTION Double-gang plate use in center compartment only, includes (1) ActivateTM adapter, and CM2 module SERIES II® PART NO. NEEDED DGT-RT DESCRIPTION Double-gang plate for center compartment mounts up to (3) Series II modules (accepts configuration 5, all parts included) CM2-U2KEYA-xx – – – – SGB-ACT Single-gang plate accepts (3) 2A Activate inserts, and CM2 module Single-gang plate accepts (3) Series II Inserts, (lower compartment) CM2-U2KEYA-xx AF3 Installation Considerations Conduit Size: .75” Capacity: Single-double, single-gang configuration (top); single (bottom) Depth behind plate: 2.75” with back plate installed DGT-RT Double-gang plate for center compartment mounts up to (6) TracJack modules (accepts configuration 1, all parts included) – – SGT-ACT Single-gang plate accepts (3) 2A Activate inserts, and CM2 module Single-gang plate accepts (3) Series II inserts, (upper compartment) SGT-3S2 CM2-U2KEYA-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 20 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE SGB-3S2 FLOOR BOXES TRACJACK® PART NO. NEEDED Single-gang plate accepts (3) TracJack inserts, (upper compartment) PART NO. NEEDED – TECHCHOICE® DESCRIPTION – PART NO. NEEDED DGT-ACT SGT-3TJ DESCRIPTION Double-gang plate for center compartment only, mounts up to (6) TechChoice modules (accepts configuration 3, CM2-U2KEYA-xx inserts sold seperately) SERIES II® PART NO. NEEDED DESCRIPTION Double-gang plate use in center compartment only, includes (1) Series II adapter DGT-RT CM2-U2KEYA-xx Single-gang plate accepts (3) TracJack inserts, (lower compartment) – – SGB-ACT Single-gang plate accepts (3) 2A Activate inserts, and CM2 module SGB-3TJ Single-gang plate accepts (3) Series II inserts, (lower compartment) SGB-3S2 CM2-U2KEYA-xx SAF Installation Considerations Conduit Size: .75” Capacity: – Depth behind plate: 2.75” with back plate installed SGC2-RT Communication plate mounts (2) TracJack modules (accepts configuration 2, all parts included) – – SGC2-ACT Communication plate mounts up to (2) TechChoice modules (accepts configuration 4, CM2-U2KEYA-xx sold separately) SGC2-RT Communication plate mounts (1) Series II module (accepts configuration 6, all parts included) CM2-U2KEYA-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 21 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE AF3 Installation Considerations Conduit Size: .75” Capacity: Single-double, single-gang configuration (top); single (bottom) Depth behind plate: 2.75” with back plate installed DESCRIPTION HDJ FLOOR BOXES TRACJACK® AC8850, AC8105 Installation Considerations Conduit Size: .5”–.75” Capacity: – Depth behind plate: 5” C8005P-3DBP DESCRIPTION Communication plate, (3) duplex KOs for 106 communication style adapter, fits both AC8850 and AC8105 boxes, and TracJack 106-type frame PART NO. NEEDED – TECHCHOICE® DESCRIPTION – OR-40800017 C8850P-RT PART NO. NEEDED C8005P-3DBP DESCRIPTION Communication plate, (3) duplex KOs for 106 communication style adapter, fits both AC8850 and AC8105 boxes, and TechChoice 106-type frame SERIES II® PART NO. NEEDED DESCRIPTION C8850P-RT Communication plate for AC8850 box mounts up to (3) Series II modules (accepts configuration 5, all parts included) C8850P-2RT Communication plate for AC8850 box mounts up to (6) Series II modules (accepts configuration 5, all parts included) OR-KS106S2 Communication plate for AC8850 box mounts up to (6) TracJack modules (accepts configuration 1, all parts included) – – C8850P-ACT Communication plate for AC8850 box mounts up to (6) TechChoice modules (accepts configuration 3, CM2-U2KEYA-xx sold separately) CM2-U2KEYA-xx C8850P-2RT Communication plate for AC8850 box mounts up to (12) TracJack modules (accepts configuration 1, all parts included) – – C8850P-2ACT Communication plate for AC8850 box mounts up to (12) TechChoice modules (accepts configuration 3, CM2-U2KEYA-xx sold separately) C8850P-3RT Communication plate for AC8850 and AC8105 boxes mounts up to (12) Series II modules (accepts configuration 5, all parts included) CM2-U2KEYA-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 22 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE PART NO. NEEDED HDJ FLOOR BOXES TRACJACK® PART NO. NEEDED AC8850, AC8105 Installation Considerations Conduit Size: .5”–.75” Capacity: – Depth behind plate: 5” C8850P-3RT DESCRIPTION Communication plate for AC8850 and AC8105 boxes mounts up to (18) TracJack modules (accepts configuration 1, all parts included) HDJ PART NO. NEEDED – TECHCHOICE® DESCRIPTION – PART NO. NEEDED C8850P-3ACT DESCRIPTION Communication plate for AC8850 and AC8105 boxes mounts up to (18) TechChoice modules (accepts configuration 3, CM2-U2KEYA-xx sold separately) SERIES II® PART NO. NEEDED – DESCRIPTION – CM2-U2KEYA-xx C8004P-2RT – – C8004P-2ACT Communication plate for AC8840 and AC8104 boxes mounts up to (12) TechChoice modules (accepts configuration 3, CM2-U2KEYA-xx sold separately) C8004P-2RT Communication plate for AC8840 and AC8104 boxes mounts up to (6) Series II modules (accepts configuration 5, all parts included) CM2-U2KEYA-xx AC10105-2 Installation Considerations Conduit Size: .5”–.75” Capacity: – Depth behind plate: – C10105P-3RT Communication plate for AC10105 box mounts up to (18) TracJack modules (accepts configuration 1, all parts included) – – C10105P-3ACT Communication plate for AC10105 box mounts up to (18) TechChoice modules (accepts configuration 3, CM2-U2KEYA-xx sold separately) C10105P-3RT Communication plate for AC10105 box mounts up to (9) Series II modules (accepts configuration 5, all parts included) CM2-U2KEYA-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 23 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE AC8840, AC8104 Installation Considerations Conduit Size: .5”–.75” Capacity: – Depth behind plate: – Communication plate for AC8840 and AC8104 boxes mounts up to (12) TracJack modules (accepts configuration 1, all parts included) FLOOR BOXES TRACJACK® PART NO. NEEDED CRFB Installation Considerations Conduit Size: .5”–.75” Capacity: – Depth behind plate: 5” CRFB-RT-1 DESCRIPTION Communication device plate mounts up to (2) TracJack modules in location 1 (see cut sheet, accepts configuration 2, all parts included) HDJ PART NO. NEEDED – TECHCHOICE® DESCRIPTION – PART NO. NEEDED CRFB-AB-1 DESCRIPTION Communication device plate mounts up to (2) TechChoice modules in location 1 (see cut sheet, accepts Configuration 4, C2-U2KEYA-xx sold separately) SERIES II® PART NO. NEEDED CRFB-RT-1 DESCRIPTION Communication device plate mounts (1) Series II module in location 1 (see cut sheet, accepts configuration 6, all parts included) CM2-U2KEYA-xx – – CRFB-AB-2 Communication device plate mounts up to (2) TechChoice modules in location 2 (see cut sheet, accepts configuration 4, C2-U2KEYA-xx sold separately) CRFB-RT-2 Communication device plate mounts (1) Series II module in location 2 (see cut sheet, accepts configuration 6, all parts included) CM2-U2KEYA-xx CRFB-RT-3 Communication device plate mounts up to (2) TracJack modules in location 3 (see cut sheet, accepts configuration 2, all parts included) – – CRFB-AB-3 Communication device plate mounts up to (2) TechChoice modules in location 3 (see cut sheet, accepts configuration 4, C2-U2KEYA-xx sold separately) CRFB-RT-3 Communication device plate mounts (1) Series II module in location 3 (see cut sheet, accepts configuration 6, all parts included) CM2-U2KEYA-xx Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 24 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE CRFB-RT-2 Communication device plate mounts up to (2) TracJack modules in location 2 (see cut sheet, accepts configuration 2, all parts included) FLOOR BOXES TRACJACK® CRFB Installation Considerations Conduit Size: .5”–.75” Capacity: – Depth behind plate: 5” HDJ PART NO. NEEDED DESCRIPTION CRFB-BEZ6A-4 Center communication plate mounts up to (6) TracJack modules (accepts configuration 1, all parts included) PART NO. NEEDED – TECHCHOICE® DESCRIPTION – PART NO. NEEDED CRFB-BEZ6A-4 DESCRIPTION Center communication plate mounts up to (6) TechChoice modules (accepts configuration 3, CM2-U2KEYA-xx sold separately) SERIES II® PART NO. NEEDED DESCRIPTION CRFB-BEZ6A-4 Center communication plate mounts up to (3) Series II modules (accepts configuration 5, all parts included) CM2-U2KEYA-xx – – – CRFB-6COM-4 CAF3 Installation Considerations Conduit Size: .5”–.75” Capacity: 3 gangs Depth behind plate: – CAF3-6A MAB6TJ Communication plate mounts up to (6) TracJack modules (accepts configuration 1, MAB6TJ sold separately) – – CAF3-6A CM2-U2KEYA-xx Communication plate mounts up to (6) TechChoice modules (accepts configuration 3, CM2-U2KEYA-xx sold separately) – CAF3-6A – Communication plate mounts up to (3) Series II modules (accepts configuration 5, MAB3S2 sold separately) MAB3S2 Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately. 25 ©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE – Center communications plate with (6) RJ knockouts, modular keystone jacks sold separately