bezel compatibility key + = + = + + + +

advertisement
BEZEL COMPATIBILITY KEY
TRACJACK®
CONFIGURATION
WIREMOLD
BEZEL PART NO.
NUMBER OF JACKS
1
MAB6TJ
2
AB2TJ-xx
+
+
=
=
TRACKJACK
TRACKJACK
DESCRIPTION
Accepts (6) TracJack jacks
Mounts up to (6) TracJack modules, modules are front-loaded
Accepts (2) TracJack jacks
Mounts up to (2) TracJack modules, modules are front-loaded
Notes: Blanking panels are available. Use part number OR-42100002-xx. “xx” denotes color options. See catalog for detailed ordering information.
TECHCHOICE®
WIREMOLD
BEZEL PART NO.
BEZEL 2 PART NO.
3
CM-MAB-xx
4
CM-2AB-xx
+
+
OR
+
+
CM2-U1KEYA-xx or CM2-U2KEYA-xx TECHCHOICE
OR
CM2-U1KEYA-xx or CM2-U2KEYA-xx TECHCHOICE
NUMBER OF JACKS
=
=
DESCRIPTION
Accepts (3–6) TechChoice jacks depending
on bezel 2 selected
Mounts up to (6) TechChoice modules,
modules are rear-loaded
Accepts (1–2) TechChoice jacks depending
on bezel 2 selected
Mounts up to (2) TechChoice modules,
modules are rear-loaded
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
CONFIGURATION
Notes: Blanking panels are available. Use part number OR-KSB10-xx. “xx” denotes color options. See catalog for detailed ordering information.
1
BEZEL COMPATIBILITY KEY
SERIES II®
CONFIGURATION
WIREMOLD BEZEL PART NO.
5
MAB3S2-xx
6
ABS2-xx
+
+
SERIES II
SERIES II
=
=
NUMBER OF JACKS
DESCRIPTION
Accepts (3) Series II jacks
Mounts up to (3) Series II modules,
modules are front-loaded
Accepts (1) Series II jack
Mounts up to (2) TechChoice modules,
modules are rear-loaded
ADDITIONAL OPTIONS
DESCRIPTION
PART NO.
Mounts TechChoice modules in a Series II
style opening
OR-KSS2210
DESCRIPTION
Mounts HDJ modules in a TrackJack style opening
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
PART NO.
OR-HDJTJA
Notes: Blanking panels are available. Use part number OR-40300164-xx. “xx” denotes color options. See catalog for detailed ordering information.
TYPICAL INSTALLATION FOR TRACJACK AND SERIES II
TYPICAL INSTALLATION FOR TECHCHOICE
1. Pull cables through unloaded bezel
1. Pull cable through unloaded bezel
2. Terminate or attach cables to module per manufacturers instructions
2. Snap bezel in to the front of the adapter plate
3. Snap module in to the front of the bezel
3. Terminate or attach cables to module per manufacturers instructions
4. Snap the bezel in to the front of the adapter plate
4. Snap module in to the back of CM2-UxKEYA-xx insert
Notes: Steps 2 and 3 are interchangeable per installers preference.
5. Snap insert in to the front of the bezel
2
FLOOR BOXES
PART NO. NEEDED
EFB6S
Installation Considerations
Conduit Size: .75”–1.25”
Capacity: 6-gangs
Depth behind plate: 3.75”
EFB8S
Installation Considerations
Conduit Size: .75”–2”
Capacity: 8-gangs
Depth behind plate: 3.5”
DESCRIPTION
HDJ
PART NO. NEEDED
TracJack faceplates
OR-403005xx
PART NO. NEEDED
OR-403HDJxx
OR-KSxxx
PART NO. NEEDED
OR-KSxxx
DESCRIPTION
Series II faceplates
OR-40300xxx
TechChoice faceplates
HDJ faceplates
OR-403HDJxx
DESCRIPTION
SERIES II®
TechChoice faceplates
HDJ faceplates
TracJack faceplates
OR-403005xx
DESCRIPTION
TECHCHOICE®
Series II faceplates
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
TRACJACK®
OR-40300xxx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
3
FLOOR BOXES
TRACJACK®
EFB10-2C
–
TECHCHOICE®
–
AB2TJ-xx
EFB10-6AB
SERIES II®
Device plate
mounts up to
(6) TechChoice
modules (accepts
configuration 3,
CM2-U2KEYA-xx
sold separately)
Mounts up to (3)
Series II modules
EFB10-3S2
CM2-U2KEYA-xx
Mounts up to (4)
TracJack modules
–
–
EFB10-2C
55074TJ-WH
Device plate
mounts up to
(6) TechChoice
modules (accepts
configuration 3,
CM2-U2KEYA-xx
sold separately)
CM2-U2KEYA-xx
Mounts up to (6)
TracJack modules
–
–
–
EFB10-2C
Device plate
mounts (1) Series II
module (accepts
configuration 6,
ABS2 bezel sold
separately)
ABS2-xx
–
–
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
EFB10S
Installation Considerations
Conduit Size: .75”–2”
Capacity: 10-gangs
Depth behind plate: 3.5”
Device plate
mounts up to (2) TracJack
modules (accepts
configuration 2,
AB2TJ bezel sold
separately)
HDJ
–
55076TJ-WH
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
4
FLOOR BOXES
TRACJACK®
DESCRIPTION
RFB2RT
Internal communication
bracket mounts
up to (4) TrackJack
devices (accepts
configuration 2, all parts included)
RFB2GFI
Internal GFI or
Decorator style receptacle bracket accepts standard
GFCI or Decorator
style receptacles,
communication or
A/V devices and
TracJack frame
PART NO. NEEDED
–
–
TECHCHOICE®
DESCRIPTION
RFB-GFI
OR-419000
DESCRIPTION
RFB22AB
Internal communication
bracket mounts up
to (4) TechChoice
devices (accepts
configuration 4, all parts included)
–
–
OR-419000
RFB4
Installation Considerations
Conduit Size: .75”–1.25”
Capacity: 4-gangs
Depth behind plate: 2”
PART NO. NEEDED
RFB2GFI
Internal GFI or
Decorator style receptacle bracket cccepts standard
GFCI or Decorator
style receptacles,
communication or
A/V devices, and
TechChoice frame
SERIES II®
PART NO. NEEDED
DESCRIPTION
Internal communication bracket
mounts (2) Series
II devices (accepts
configuration 6, all parts included)
RFB2RT
–
–
OR-KSDS4
Internal GFI
bracket accepts
standard GFCI or
Decorator style
receptacles, communication or A/V devices, and TracJack
stylistic frame
–
–
RFB4-LPB
Communication
bracket mounts up
to (6) TechChoice
devices (accepts
configuration 3,
CM2-UxKEYA-xx
inserts sold separately)
RFB4-LPBS2
Communication
bracket mounts
up to (3) Series II
devices (accepts
configuration 5, all parts included)
CM2-U2KEYA-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
5
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
RFB2
Installation Considerations
Conduit Size: .75”–1.25”
Capacity: 2-gangs
Depth behind plate: 3”
PART NO. NEEDED
HDJ
FLOOR BOXES
TRACJACK®
RFB4
Installation Considerations
Conduit Size: .75”–1.25”
Capacity: 4-gangs
Depth behind plate: 2”
DTB-2-DECORA
DESCRIPTION
Communication
bracket Decorator
style opening for
Decorator style 106 adapter, and TracJack 106-type frame
PART NO. NEEDED
–
TECHCHOICE®
DESCRIPTION
–
OR-419000
–
PART NO. NEEDED
DTB-2-2AB
Communication
bracket mounts up
to (6) TechChoice
devices (accepts
configuration 3,
CM2-UxKEYA-xx
inserts sold separately)
PART NO. NEEDED
DTB-2-2RT
DESCRIPTION
Communication
bracket mounts (2) Series II devices (accepts
configuration 6, all parts included)
CM2-U2KEYA-xx
–
–
–
DTB-2-4TKO
DTB-2-2RT
DESCRIPTION
SERIES II®
Communication
bracket mounts (4) TracJack
devices (accepts
configuration 2, all parts included)
–
–
WTB-2-AB
Communication
bracket (4) RJ
keystone opening
knockouts, use as
blank plate or for
up to (4) RJ openings
Communication
bracket mounts up
to (6) TechChoice
devices (accepts
configuration 3,
CM2-UxKEYA-xx
inserts sold separately)
WTB-2-RT
–
Communication
bracket mounts (1) Series II device (accepts
configuration 6, all parts included)
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
PART NO. NEEDED
HDJ
–
CM2-U2KEYA-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
6
FLOOR BOXES
TRACJACK®
PART NO. NEEDED
RFB4
Installation Considerations
Conduit Size: .75”–1.25”
Capacity: 4-gangs
Depth behind plate: 2”
–
HDJ
DESCRIPTION
–
PART NO. NEEDED
–
TECHCHOICE®
DESCRIPTION
–
PART NO. NEEDED
RFB-GFI
DESCRIPTION
SERIES II®
PART NO. NEEDED
DESCRIPTION
Internal GFI
bracket accepts
standard GFCI
or Decorator
style receptacles,
communication or
A/V devices, and
TechChoice stylistic frame
–
–
Communication
bracket Decorator
style opening for
Decorator style
106 adapter and
TechChoice stylistic frame
and TechChoice
106-type frame
–
–
Communication
bracket with duplex
opening for use
with 106 adapter,
sold separately,
devices not included,
and TechChoice
106-type frame
–
–
OR-KSDS4
–
–
–
–
DTB-2-DECORA
–
–
–
–
DTB-2-SD
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
OR-KSDS4
OR-KS106S2
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
7
FLOOR BOXES
TRACJACK®
RFB4E
Installation Considerations
Conduit Size: .75”–2”
Capacity: 4-gangs
Depth behind plate: 3.5”
RFB6RT
RFB6GFI
DESCRIPTION
Internal
communication
bracket mounts
up to (4) TrackJack
devices (accepts
configuration 2, all parts included)
Internal GFI or
Decorator style
receptacle bracket
accepts standard
GFCI and Decorator
style receptacles,
communication or A/V devices, and TracJack
stylistic frame
PART NO. NEEDED
–
TECHCHOICE®
DESCRIPTION
–
CM2-U2KEYA-xx
–
–
OR-419000
RFB6
RFB6E
Installation Considerations
Conduit Size: .75”–1.25”
Capacity: 6-gangs
Depth behind plate: 3.25”
RFB6RT
PART NO. NEEDED
RFB6GFI
DESCRIPTION
Internal communication
bracket mounts up to (4) TechChoice
devices (accepts
configuration 4,
CM2-UxKEYA-xx
inserts sold separately)
SERIES II®
PART NO. NEEDED
DESCRIPTION
RFB6RT
Internal
communication
bracket mounts (2) Series II devices (accepts
configuration 6,
all parts included)
Internal GFI or
Decorator style
receptacle bracket
accepts standard
GFCI and Decorator
style receptacles,
communication or A/V devices,
and TechChoice
stylistic frame
–
–
OR-KSDS4
Internal communication bracket
mounts up to (4) TrackJack
devices (accepts
configuration 2, all parts included)
–
–
CM2-U2KEYA-xx
Internal
communication
bracket mounts up to (4) TechChoice
devices (accepts
configuration 4,
CM2-UxKEYA-xx
inserts sold separately)
RFB6RT
Internal communication
bracket mounts (2) Series II devices (accepts
configuration 6, all parts included)
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
8
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
PART NO. NEEDED
HDJ
FLOOR BOXES
TRACJACK®
RFB6
RFB6GFI
RFB6E
Installation Considerations
Conduit Size: .75”–1.25”
Capacity: 6-gangs
Depth behind plate: 3.25”
Internal GFI or
Decorator style
receptacle bracket
accepts standard
GFCI and Decorator
style receptacles,
communication or A/V devices, and TracJack
stylistic frame
PART NO. NEEDED
–
DESCRIPTION
–
OR-419000
RFB9
Installation Considerations
Conduit Size: .75”–2”
Capacity: 9-gangs
Depth behind plate: 2.5”
RFB119-2SRT
RFB11
Installation Considerations
Conduit Size: .75”–2”
Capacity: 11-gangs
Depth behind plate: 2.5”
DESCRIPTION
TECHCHOICE®
PART NO. NEEDED
RFB6GFI
DESCRIPTION
Internal GFI or
Decorator style receptacle bracket
accepts standard
GFCI and Decorator
style receptacles,
communication or A/V devices,
and TechChoice
stylistic frame
SERIES II®
PART NO. NEEDED
–
DESCRIPTION
–
OR-KSDS4
Communication
device plate
mounts up to (6)
TracJack devices
in a 2-gang
sectional width
footprint (accepts
configuration 1, all parts included)
–
–
RFB119-2SAB
Communication
device plate
mounts up to
(6) TechChoice
devices in a 2-gang
sectional width
footprint (accepts
configuration 3,
CM2-UxKEYA-xx
inserts sold separately)
RFB119-2SRT
Communication
device plate
mounts up to (3) Series II devices in a 2-gang
sectional width
footprint (accepts
configuration 5,
all parts included)
CM2-U2KEYA-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
9
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
PART NO. NEEDED
HDJ
FLOOR BOXES
TRACJACK®
PART NO. NEEDED
RFB9
Installation Considerations
Conduit Size: .75”–2”
Capacity: 9-gangs
Depth behind plate: 2.5”
RFB119-RT
DESCRIPTION
Communication
device plate
mounts up to (6)
TracJack devices
in a standard width
footprint (accepts
configuration 1, all
parts included)
HDJ
PART NO. NEEDED
–
TECHCHOICE®
DESCRIPTION
–
RFB11
Installation Considerations
Conduit Size: .75”–2”
Capacity: 11-gangs
Depth behind plate: 2.5”
880W
Installation Considerations
Conduit Size: .5”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
RFB119-AB
DESCRIPTION
Communication
device plate
mounts up to (6)
TechChoice devices
in a standard width
footprint (accepts
configuration 3,
CM2-UxKEYA-xx
inserts sold separately)
PART NO. NEEDED
RFB119-RT
DESCRIPTION
Communication
device plate
mounts up to (3) Series II devices in a 2-gang
sectional width
footprint (accepts
configuration 5, all parts included)
CM2-U2KEYA-xx
817B
1-gang brass combination carpet and tile
flange mounts up to (6) TracJack
devices (accepts
configuration 1,
MAB6TJ bezel sold
separately)
817B
–
–
CM-MAB-xx
MAB6TJ
1-gang brass
combination carpet and tile
flange mounts up
to (6) TechChoice
devices (accepts
configuration 3,
CM-MAB-xx bezel
and CM2-UxKEYA-xx
inserts sold separately)
817B
1-gang brass combination carpet and tile
flange mounts
up to (3) Series II
devices (accepts
configuration 5,
MAB3S2 bezel sold separately)
MAB3S2
CM2-U2KEYA-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
10
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
OMNIBOX
Installation Considerations
Conduit Size: .25”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
PART NO. NEEDED
SERIES II®
FLOOR BOXES
TRACJACK®
PART NO. NEEDED
880W
Installation Considerations
Conduit Size: .5”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
827B
2-gang brass combination
carpet and tile
flange mounts up
to (12) TracJack
devices (accepts
configuration 1,
MAB6TJ bezel sold
separately)
PART NO. NEEDED
TECHCHOICE®
DESCRIPTION
PART NO. NEEDED
827B
–
–
CM-MAB-xx
MAB6TJ
DESCRIPTION
2-gang brass combination carpet
and tile flange
accepts CM series
inserts, sold separately, CM
bezel, and CM2 module
SERIES II®
PART NO. NEEDED
827B
DESCRIPTION
2-gang brass combination
carpet and tile
flange mounts
up to (6) Series II
devices (accepts
configuration 5,
MAB3S2 bezel
sold separately)
MAB3S2
CM2-U2KEYA-xx
837B
3-gang brass combination
carpet and tile
flange mounts up
to (18) TracJack
devices (accepts
configuration 1,
MAB6TJ bezel sold
separately)
837B
–
–
CM-MAB-xx
MAB6TJ
3-gang brass combination carpet
and tile flange
mounts up to (18) TechChoice
837B
devices (accepts
configuration 3,
CM-MAB-xx bezel
and CM2-UxKEYA-xx
inserts sold separately)
3-gang brass
combination
carpet and tile
flange mounts
up to (9) Series II
devices (accepts
configuration 5,
MAB3S2 bezel
sold separately)
MAB3S2
CM2-U2KEYA-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
11
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
OMNIBOX
Installation Considerations
Conduit Size: .25”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
DESCRIPTION
HDJ
FLOOR BOXES
TRACJACK®
PART NO. NEEDED
880W
Installation Considerations
Conduit Size: .5”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
818TCAL
1-gang aluminum
combination
carpet and tile
flange mounts up
to (6) TracJack
devices (accepts
configuration 1,
MAB6TJ bezel
sold separately)
PART NO. NEEDED
TECHCHOICE®
DESCRIPTION
PART NO. NEEDED
818TCAL
–
–
CM-MAB-xx
MAB6TJ
DESCRIPTION
SERIES II®
PART NO. NEEDED
1-gang aluminum
combination
carpet and tile
flange mounts up
to (6) TechChoice
818TCAL
devices (accepts
configuration 3,
CM-MAB-xx bezel
and CM2-UxKEYA-xx
inserts sold
separately)
DESCRIPTION
1-gang aluminum
combination carpet and tile
flange mounts up
to (3) Series II
devices (accepts
configuration 5,
MAB3S2 bezel sold
separately)
MAB3S2
CM2-U2KEYA-xx
828TCAL
2-gang aluminum
combination
carpet and tile
flange mounts up
to (12) TracJack
devices (accepts
configuration 1,
MAB6TJ bezel
old separately)
828TCAL
–
–
CM-MAB-xx
MAB6TJ
2-gang aluminum
combination carpet
and tile flange
mounts up to (12) TechChoice
828TCAL
devices (accepts
configuration 3,
CM-MAB-xx bezel
and CM2-UxKEYA-xx
inserts sold separately)
2-gang aluminum
combination
carpet and tile
flange mounts
up to (6) Series II
devices (accepts
configuration 5,
MAB3S2 bezel sold
separately)
MAB3S2
CM2-U2KEYA-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
12
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
OMNIBOX
Installation Considerations
Conduit Size: .25”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
DESCRIPTION
HDJ
FLOOR BOXES
TRACJACK®
PART NO. NEEDED
880W
Installation Considerations
Conduit Size: .5”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
838TCAL
3-gang aluminum
combination
carpet and tile
flange mounts up
to (18) TracJack
devices (accepts
configuration 1,
MAB6TJ bezel sold separately)
PART NO. NEEDED
TECHCHOICE®
DESCRIPTION
PART NO. NEEDED
838TCAL
–
–
CM-MAB-xx
DESCRIPTION
SERIES II®
PART NO. NEEDED
3-gang aluminum
combination carpet and tile
flange mounts up
to (18) TechChoice
838TCAL
devices (accepts
configuration 3,
CM-MAB-xx bezel
and CM2-UxKEYA-xx
inserts sold
separately)
MAB6TJ
DESCRIPTION
3-gang aluminum
combination carpet and tile
flange mounts
up to (9) Series II
devices (accepts
configuration 5,
MAB3S2 bezel sold separately)
MAB3S2
CM2-U2KEYA-xx
817TCAL
1-gang
powder-coated
aluminum
combination
carpet and tile
flange mounts up
to (6) TracJack
devices (accepts
configuration 1,
MAB6TJ bezel sold
separately)
817TCAL
–
–
CM-MAB-xx
MAB6TJ
1-gang powder-coated
aluminum combination carpet
and tile flange
mounts up to (6) TechChoice
devices (accepts
configuration 3,
CM-MAB-xx bezel
and CM2-UxKEYA-xx
inserts sold separately)
817TCAL
1-gang powder-coated
aluminum combination carpet and tile
flange mounts
up to (3) Series II
devices (accepts
configuration 5,
MAB3S2 bezel sold separately)
MAB3S2
CM2-U2KEYA-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
13
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
OMNIBOX
Installation Considerations
Conduit Size: .25”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
DESCRIPTION
HDJ
FLOOR BOXES
TRACJACK®
PART NO. NEEDED
880W
Installation Considerations
Conduit Size: .5”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
827TCAL
2-gang powder-coated
aluminum
combination
carpet and tile
flange mounts up
to (12) TracJack
devices (accepts
configuration 1,
MAB6TJ bezel sold separately)
PART NO. NEEDED
TECHCHOICE®
DESCRIPTION
PART NO. NEEDED
827TCAL
–
–
CM-MAB-xx
MAB6TJ
DESCRIPTION
SERIES II®
PART NO. NEEDED
DESCRIPTION
2-gang
powder-coated
aluminum
combination
carpet and tile
flange mounts up
827TCAL
to (12) TechChoice
devices (accepts
configuration 3,
CM-MAB-xx bezel
and CM2-UxKEYA-xx
inserts sold separately)
MAB3S2
1-gang aluminum
combination
carpet and tile
flange mounts up
to (3) Series II
devices (accepts
configuration 5,
MAB3S2 bezel
sold separately)
2-gang aluminum
combination carpet
and tile flange
mounts up to (12) TechChoice
devices (accepts
configuration 3,
CM-MAB-xx bezel
and CM2-UxKEYA-xx
inserts sold separately)
2-gang aluminum
combination
carpet and tile
flange mounts
up to (6) Series II
devices (accepts
configuration 5,
MAB3S2 bezel
sold separately)
CM2-U2KEYA-xx
837TCAL
3-gang
powder-coated
aluminum
combination
carpet and tile
flange mounts up
to (18) TracJack
devices (accepts
configuration 1,
MAB6TJ bezel sold separately)
837TCAL
–
–
CM-MAB-xx
MAB6TJ
837TCAL
MAB3S2
CM2-U2KEYA-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
14
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
OMNIBOX
Installation Considerations
Conduit Size: .25”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
DESCRIPTION
HDJ
FLOOR BOXES
TRACJACK®
PART NO. NEEDED
OMNIBOX
Installation Considerations
Conduit Size: .25”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
880W
Installation Considerations
Conduit Size: .5”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
DESCRIPTION
HDJ
PART NO. NEEDED
TECHCHOICE®
DESCRIPTION
PART NO. NEEDED
817PCC-BLK
817PCC-BLK
829PFLRT
1-gang non-metallic
carpet flange
mounts up to (6) TracJack
devices, use
with 829PFLRT
cover (accepts
configuration 1,
MAB6TJ bezel
included with
829PFLRT cover,
sold separately)
–
–
829PFL
CM2-U2KEYA-xx
DESCRIPTION
1-gang nonmetallic carpet
flange mounts up
to (6) TechChoice
devices, use
with 829PFL
cover (accepts
configuration 3,
CM-MAB-xx
bezel included with
829PFL cover, sold
separately, CM2UxKEYA-xx inserts
sold separately)
SERIES II®
PART NO. NEEDED
817PCC-BLK
829PFLRT
DESCRIPTION
1-gang
nonmetallic carpet
flange mounts
up to (3) Series II
devices, use with 829PFLRT
cover (accepts
configuration 1,
MAB3S2 bezel
included with
829PFLRT cover,
sold separately)
MAB3S2
MAB6TJ
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
CM-MAB-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
15
FLOOR BOXES
TRACJACK®
PART NO. NEEDED
OMNIBOX
Installation Considerations
Conduit Size: .25”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
880W
Installation Considerations
Conduit Size: .5”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
827PCC-BLK
829PFLRT
DESCRIPTION
2-gang
nonmetallic carpet flange
mounts up to (12) TracJack devices, use with 829PFLRT
covers (accepts
configuration 1,
MAB6TJ bezel
included with
829PFLRT covers,
sold separately)
HDJ
PART NO. NEEDED
–
TECHCHOICE®
DESCRIPTION
–
PART NO. NEEDED
DESCRIPTION
827PCC-BLK
2-gang nonmetallic carpet
flange mounts up
to (12) TechChoice
devices, use with 829PFL covers (accepts
configuration 3,
CM-MAB-xx bezel included with 829PFL covers, sold separately, CM2-UxKEYA-xx
inserts sold separately)
829PFL
CM2-U2KEYA-xx
MAB6TJ
SERIES II®
PART NO. NEEDED
827PCC-BLK
829PFLRT
DESCRIPTION
2-gang nonmetallic carpet flange
mounts up to (6)
Series II devices,
use with 829PFLRT
covers (accepts
configuration 1,
MAB3S2 bezel
included with
829PFLRT covers,
sold separately)
MAB3S2
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
CM-MAB-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
16
FLOOR BOXES
TRACJACK®
PART NO. NEEDED
880W
Installation Considerations
Conduit Size: .5”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
PART NO. NEEDED
TECHCHOICE®
DESCRIPTION
PART NO. NEEDED
DESCRIPTION
SERIES II®
PART NO. NEEDED
DESCRIPTION
837PCC-BLK
837PCC-BLK
829PFLRT
3-gang
nonmetallic carpet
flange mounts up to (18) TracJack
devices, use with 829PFLRT
covers (accepts
configuration 1,
MAB6TJ bezel sold separately)
–
–
829PFL
CM2-U2KEYA-xx
3-gang nonmetallic
carpet flange
837PCC-BLK
mounts up to (18) TechChoice
devices, use with 829PFL covers (accepts
configuration 3,
829PFLRT
CM-MAB-xx bezel
and CM2-UxKEYA-xx
inserts sold separately)
MAB6TJ
3-gang nonmetallic carpet flange
mounts up to (9)
Series II devices,
use with 829PFLRT
covers (accepts
configuration 5,
MAB3S2 bezel sold separately)
MAB3S2
CM-MAB-xx
RATCHET-PRO
Installation Considerations
Conduit Size: 1”
Capacity: 1-gang
Depth behind plate: 1.75”
RPAV3CTCxx
Multiple service
cover kit includes
(1) prewired 20A
duplex receptacle,
flange and slide
holder, adapter
ring, divider and
bezel to mount (2) TracJack
modules (accepts
configuration 2, all parts included)
–
–
RPAV3CTCxx
Multiple service
cover kit includes
(1) prewired 20A
duplex receptacle,
flange and slide
holder, adapter
ring, divider and
bezel to mount (1)
CM2-UxKEYA-xx
insert (accepts
configuration 4, all parts included)
RPAV3CTCxx
Multiple service
cover kit includes
(1) prewired 20A
duplex receptacle,
flange and slide
holder, adapter
ring, divider and
bezel to mount (1) Series II module (accepts
configuration 6, all
parts included)
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
17
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
OMNIBOX
Installation Considerations
Conduit Size: .25”–.75”
Capacity: 1,2, or 3-gangs
Depth behind plate: 2.75”
DESCRIPTION
HDJ
FLOOR BOXES
PART NO. NEEDED
RATCHET-PRO
Installation Considerations
Conduit Size: 1”
Capacity: 1-gang
Depth behind plate: 1.75”
RP4CTCxx
RP7CTCxx
DESCRIPTION
Multiple service
cover kit for RPSFB, RFSFB-OG,
and RPNFB floor
boxes includes (2) prewired 20A duplex receptacles, flange
and slide holder,
adapter ring,
divider and bezels
to mount TracJack
modules (accepts
configuration 2, all parts included)
Multiple service
cover kit includes
(1) prewired 20A
duplex receptacle,
flange and slide
holder, adapter
ring, divider and bezel to mount TracJack
modules (accepts
configuration 2, all parts included)
HDJ
PART NO. NEEDED
–
TECHCHOICE®
DESCRIPTION
PART NO. NEEDED
–
RP4CTCxx
–
–
RP7CTCxx
DESCRIPTION
Multiple service
cover kit for RPSFB,
and
RPNFB
RFSFB-OG,
floor
boxes includes
(2) prewired 20A
duplex receptacles,
flange and slide
holder, adapter
ring, divider and
bezels to mount
CM2-UxKEYA-xx
inserts (accepts
configuration 4, all parts included)
Multiple service
cover kit includes
(1) prewired 20A
duplex receptacle,
flange and slide
holder, adapter
ring, divider and
bezels to mount
CM2-UxKEYA-xx
inserts (accepts
configuration 4, all parts included)
SERIES II®
PART NO. NEEDED
RP4CTCxx
RP7CTCxx
DESCRIPTION
Multiple service
cover kit for RPSFB, RFSFB-OG,
and RPNFB floor
boxes includes
(2) prewired 20A
duplex receptacles,
flange and slide
holder, adapter
ring, divider and bezels to
mount Series II
modules (accepts
configuration 6, all parts included)
Multiple service
cover kit includes
(1) prewired 20A duplex receptacle, flange
and slide holder,
adapter ring,
divider and bezels
to mount Series II
modules (accepts
configuration 6, all parts included)
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
18
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
TRACJACK®
FLOOR BOXES
PART NO. NEEDED
RATCHET-PRO
Installation Considerations
Conduit Size: 1”
Capacity: 1-gang
Depth behind plate: 1.75”
RPAMD4CTCxx
RPAMD8CTCxx
AF1
Installation Considerations
Conduit Size: .5”
Capacity: Single or double-gang
Depth behind plate: 2.75”
with back plate installed
DGT-RT
DESCRIPTION
Single service floor
box cover kit with
adapter ring and
bezels to mount (4) TracJack
modules (accepts
configuration 2, all parts included)
Single service floor box cover
kit with adapter
ring and bezels to
mount TracJack
modules (accepts
configuration 2, all
parts included)
Double-gang plate for center
compartment
mounts up to (6) TracJack
modules (accepts
configuration 1, all parts included)
HDJ
PART NO. NEEDED
–
TECHCHOICE®
DESCRIPTION
PART NO. NEEDED
–
RPAMD4CTCxx
–
–
RPAMD8CTCxx
–
–
SGT-ACT
DESCRIPTION
Single service floor
box cover kit with
adapter ring and
bezels to mount
(4) TechChoice
modules (accepts
configuration 4, all parts included)
Single service
floor box cover
kit with adapter
ring and bezels to
mount TechChoice
modules (accepts
configuration 4, all parts included)
SERIES II®
PART NO. NEEDED
RPAMD4CTCxx
RPAMD8CTCxx
Single-gang plate accepts (3) 2A
ActivateTM inserts,
and CM2 module
DESCRIPTION
Single service floor
box cover kit with
adapter ring and
bezels to mount (2) Series II
modules (accepts
configuration 6, all parts included)
Single service floor box cover
kit with adapter
ring and bezels
to mount Series II
modules (accepts
configuration 6, all parts included)
Single-gang plate accepts (3) Series II
inserts (upper
compartment)
SGT-3S2
CM2-U2KEYA-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
19
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
TRACJACK®
FLOOR BOXES
TRACJACK®
PART NO. NEEDED
AF1
Installation Considerations
Conduit Size: .5”
Capacity: Single or double-gang
Depth behind plate: 2.75”
with back plate installed
HDJ
DESCRIPTION
Single-gang plate accepts (3) TracJack
inserts, (upper
compartment)
PART NO. NEEDED
–
TECHCHOICE®
DESCRIPTION
–
PART NO. NEEDED
DGT-ACT
SGT-3TJ
DESCRIPTION
Double-gang plate use in center
compartment
only, includes
(1) ActivateTM
adapter, and CM2 module
SERIES II®
PART NO. NEEDED
DGT-RT
DESCRIPTION
Double-gang plate for center
compartment
mounts up to (3) Series II
modules (accepts
configuration 5, all parts included)
CM2-U2KEYA-xx
–
–
–
–
SGB-ACT
Single-gang plate
accepts (3) 2A Activate inserts,
and CM2 module
Single-gang plate
accepts (3) Series II
Inserts, (lower
compartment)
CM2-U2KEYA-xx
AF3
Installation Considerations
Conduit Size: .75”
Capacity: Single-double,
single-gang configuration
(top); single (bottom)
Depth behind plate: 2.75”
with back plate installed
DGT-RT
Double-gang plate for center
compartment
mounts up to (6) TracJack
modules (accepts
configuration 1, all parts included)
–
–
SGT-ACT
Single-gang plate
accepts (3) 2A
Activate inserts,
and CM2 module
Single-gang plate
accepts (3) Series II
inserts, (upper
compartment)
SGT-3S2
CM2-U2KEYA-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
20
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
SGB-3S2
FLOOR BOXES
TRACJACK®
PART NO. NEEDED
Single-gang
plate accepts
(3) TracJack
inserts, (upper
compartment)
PART NO. NEEDED
–
TECHCHOICE®
DESCRIPTION
–
PART NO. NEEDED
DGT-ACT
SGT-3TJ
DESCRIPTION
Double-gang
plate for center
compartment
only, mounts up
to (6) TechChoice
modules (accepts
configuration 3,
CM2-U2KEYA-xx
inserts sold seperately)
SERIES II®
PART NO. NEEDED
DESCRIPTION
Double-gang plate
use in center
compartment only, includes
(1) Series II adapter
DGT-RT
CM2-U2KEYA-xx
Single-gang
plate accepts
(3) TracJack
inserts, (lower compartment)
–
–
SGB-ACT
Single-gang plate
accepts (3) 2A
Activate inserts,
and CM2 module
SGB-3TJ
Single-gang plate
accepts (3) Series II
inserts, (lower
compartment)
SGB-3S2
CM2-U2KEYA-xx
SAF
Installation Considerations
Conduit Size: .75”
Capacity: –
Depth behind plate: 2.75”
with back plate installed
SGC2-RT
Communication
plate mounts (2) TracJack
modules (accepts
configuration 2, all parts included)
–
–
SGC2-ACT
Communication
plate mounts up
to (2) TechChoice
modules (accepts
configuration 4,
CM2-U2KEYA-xx
sold separately)
SGC2-RT
Communication
plate mounts (1) Series II module (accepts
configuration 6, all parts included)
CM2-U2KEYA-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
21
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
AF3
Installation Considerations
Conduit Size: .75”
Capacity: Single-double,
single-gang configuration
(top); single (bottom)
Depth behind plate: 2.75”
with back plate installed
DESCRIPTION
HDJ
FLOOR BOXES
TRACJACK®
AC8850, AC8105
Installation Considerations
Conduit Size: .5”–.75”
Capacity: –
Depth behind plate: 5”
C8005P-3DBP
DESCRIPTION
Communication
plate, (3) duplex
KOs for 106
communication
style adapter, fits
both AC8850 and
AC8105 boxes,
and TracJack 106-type frame
PART NO. NEEDED
–
TECHCHOICE®
DESCRIPTION
–
OR-40800017
C8850P-RT
PART NO. NEEDED
C8005P-3DBP
DESCRIPTION
Communication
plate, (3) duplex
KOs for 106
communication
style adapter, fits
both AC8850 and
AC8105 boxes, and TechChoice
106-type frame
SERIES II®
PART NO. NEEDED
DESCRIPTION
C8850P-RT
Communication
plate for AC8850
box mounts up
to (3) Series II
modules (accepts
configuration 5, all
parts included)
C8850P-2RT
Communication
plate for AC8850 box mounts up to (6) Series II modules (accepts
configuration 5, all
parts included)
OR-KS106S2
Communication
plate for AC8850
box mounts up to (6) TracJack
modules (accepts
configuration 1, all parts included)
–
–
C8850P-ACT
Communication
plate for AC8850
box mounts up
to (6) TechChoice
modules (accepts
configuration 3,
CM2-U2KEYA-xx
sold separately)
CM2-U2KEYA-xx
C8850P-2RT
Communication
plate for AC8850
box mounts up
to (12) TracJack
modules (accepts
configuration 1, all parts included)
–
–
C8850P-2ACT
Communication
plate for AC8850
box mounts up to
(12) TechChoice
modules (accepts
configuration 3,
CM2-U2KEYA-xx
sold separately)
C8850P-3RT
Communication
plate for AC8850
and AC8105 boxes
mounts up to (12) Series II
modules (accepts
configuration 5, all
parts included)
CM2-U2KEYA-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
22
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
PART NO. NEEDED
HDJ
FLOOR BOXES
TRACJACK®
PART NO. NEEDED
AC8850, AC8105
Installation Considerations
Conduit Size: .5”–.75”
Capacity: –
Depth behind plate: 5”
C8850P-3RT
DESCRIPTION
Communication
plate for AC8850
and AC8105 boxes
mounts up to (18) TracJack
modules (accepts
configuration 1, all parts included)
HDJ
PART NO. NEEDED
–
TECHCHOICE®
DESCRIPTION
–
PART NO. NEEDED
C8850P-3ACT
DESCRIPTION
Communication
plate for AC8850
and AC8105 boxes
mounts up to
(18) TechChoice
modules (accepts
configuration 3,
CM2-U2KEYA-xx
sold separately)
SERIES II®
PART NO. NEEDED
–
DESCRIPTION
–
CM2-U2KEYA-xx
C8004P-2RT
–
–
C8004P-2ACT
Communication
plate for AC8840
and AC8104 boxes
mounts up to
(12) TechChoice
modules (accepts
configuration 3,
CM2-U2KEYA-xx
sold separately)
C8004P-2RT
Communication
plate for AC8840
and AC8104 boxes
mounts up to (6) Series II modules (accepts
configuration 5, all parts included)
CM2-U2KEYA-xx
AC10105-2
Installation Considerations
Conduit Size: .5”–.75”
Capacity: –
Depth behind plate: –
C10105P-3RT
Communication
plate for AC10105
box mounts up
to (18) TracJack
modules (accepts
configuration 1, all
parts included)
–
–
C10105P-3ACT
Communication
plate for AC10105
box mounts up to
(18) TechChoice
modules (accepts
configuration 3,
CM2-U2KEYA-xx
sold separately)
C10105P-3RT
Communication
plate for AC10105
box mounts up to (9) Series II modules (accepts
configuration 5, all parts included)
CM2-U2KEYA-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
23
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
AC8840, AC8104
Installation Considerations
Conduit Size: .5”–.75”
Capacity: –
Depth behind plate: –
Communication
plate for AC8840
and AC8104 boxes
mounts up to (12) TracJack
modules (accepts
configuration 1, all parts included)
FLOOR BOXES
TRACJACK®
PART NO. NEEDED
CRFB
Installation Considerations
Conduit Size: .5”–.75”
Capacity: –
Depth behind plate: 5”
CRFB-RT-1
DESCRIPTION
Communication
device plate
mounts up to (2) TracJack modules in
location 1 (see cut
sheet, accepts
configuration 2, all parts included)
HDJ
PART NO. NEEDED
–
TECHCHOICE®
DESCRIPTION
–
PART NO. NEEDED
CRFB-AB-1
DESCRIPTION
Communication
device plate
mounts up to (2) TechChoice
modules in
location 1 (see cut
sheet, accepts
Configuration 4,
C2-U2KEYA-xx
sold separately)
SERIES II®
PART NO. NEEDED
CRFB-RT-1
DESCRIPTION
Communication
device plate
mounts (1) Series II module in location 1 (see
cut sheet, accepts
configuration 6, all
parts included)
CM2-U2KEYA-xx
–
–
CRFB-AB-2
Communication
device plate
mounts up to (2) TechChoice
modules in
location 2 (see cut
sheet, accepts
configuration 4,
C2-U2KEYA-xx
sold separately)
CRFB-RT-2
Communication
device plate
mounts (1) Series II module
in location 2 (see
cut sheet, accepts
configuration 6, all parts included)
CM2-U2KEYA-xx
CRFB-RT-3
Communication
device plate
mounts up to (2) TracJack
modules in
location 3 (see cut
sheet, accepts
configuration 2, all parts included)
–
–
CRFB-AB-3
Communication
device plate
mounts up to (2) TechChoice
modules in
location 3 (see cut
sheet, accepts
configuration 4,
C2-U2KEYA-xx
sold separately)
CRFB-RT-3
Communication
device plate
mounts (1) Series II module
in location 3 (see
cut sheet, accepts
configuration 6, all
parts included)
CM2-U2KEYA-xx
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
24
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
CRFB-RT-2
Communication
device plate
mounts up to (2) TracJack modules in
location 2 (see cut
sheet, accepts
configuration 2, all parts included)
FLOOR BOXES
TRACJACK®
CRFB
Installation Considerations
Conduit Size: .5”–.75”
Capacity: –
Depth behind plate: 5”
HDJ
PART NO. NEEDED
DESCRIPTION
CRFB-BEZ6A-4
Center communication
plate mounts up
to (6) TracJack
modules (accepts
configuration 1, all
parts included)
PART NO. NEEDED
–
TECHCHOICE®
DESCRIPTION
–
PART NO. NEEDED
CRFB-BEZ6A-4
DESCRIPTION
Center
communication
plate mounts up
to (6) TechChoice
modules (accepts
configuration 3,
CM2-U2KEYA-xx
sold separately)
SERIES II®
PART NO. NEEDED
DESCRIPTION
CRFB-BEZ6A-4
Center
communication
plate mounts up
to (3) Series II
modules (accepts
configuration 5, all
parts included)
CM2-U2KEYA-xx
–
–
–
CRFB-6COM-4
CAF3
Installation Considerations
Conduit Size: .5”–.75”
Capacity: 3 gangs
Depth behind plate: –
CAF3-6A
MAB6TJ
Communication
plate mounts up
to (6) TracJack
modules (accepts
configuration 1,
MAB6TJ sold separately)
–
–
CAF3-6A
CM2-U2KEYA-xx
Communication
plate mounts up
to (6) TechChoice
modules (accepts
configuration 3,
CM2-U2KEYA-xx
sold separately)
–
CAF3-6A
–
Communication
plate mounts up
to (3) Series II
modules (accepts
configuration 5,
MAB3S2 sold
separately)
MAB3S2
Notes: Parts represented by photos or drawings indicate unique parts that need to be ordered for the installation. If the part is not shown, it is packaged with another item in the installation. All modular jacks sold separately.
25
©2015 Legrand All Rights Reserved rev. 10|15 WM-FB-GUIDE
–
Center
communications
plate with (6) RJ
knockouts, modular
keystone jacks
sold separately
Download