Emergency UL924 Bypass / Shunt Relays Description Our UL924 Emergency Bypass/Shunt Relays are designed for applications that require an emergency load to be switched on during a loss of normal power. These economically priced relays are available prepackaged in their own NEMA 1 enclosure or panel versions to be installed inside an existing enclosure. Operation UL 924 Emergency Bypass/Shunt relays will switch a lighting load upon loss of normal power downstream of an emergency transfer switch, bypassing wall switch position. Features • Multi-coil voltage input Models can be ordered with a two position closed/ auto override test switch or with a custom two position momentary on/auto override test switch. These switches can be used to verify your emergency load is being switched properly during initial field wiring. • 10, 15, 20 Amp Contact Ratings Specifications • Red LED utility power indicator See reverse side. • Two position override test switch available • Custom two position momentary override test switch available • NEMA 1 enclosure • Pre wired and prepackaged for convenience • Mounts easily through ½” knockout or remotely on flat surfaces • Bright yellow color for easy identification • Panel style for use inside control panels • UL 924 & California State Fire Marshall • DPDT configurations • 5 year warranty • Made in USA Functional Devices, Inc. 310 South Union Street P.O. Box 368 Russiaville, IN 46979 ESRU1S Office Sales Fax Email 765.883.5538 800.888.5538 765.883.7505 sales@functionaldevices.com UL924 / 10 Amp Emergency Bypass/Shunt Relay Enclosed Relay 10 Amp SPST-N/O + Override with 10-30 Vac/dc/120 Vac Coil Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac 600 Watt Tungsten @ 120 Vac N/O 240 Watt Tungsten @ 120 Vac N/C 1/3 HP for N/O @ 120-240 Vac 1/6 HP for N/C @ 120-240 Vac 1/4 HP for N/O @ 277 Vac 1/8 HP for N/C @ 277 Vac SPECIFICATIONS # Relays & Contact Type: Expected Relay Life: Operating Temperature: Operate Time: Relay Status: Dimensions: Wires: Approvals: Housing Rating: Gold Flash: Override Switch: One (1) SPST Continuous Duty Coil 10 million cycles minimum mechanical -30 to 140° F 20mS LED On = Activated 2.30˝ x 3.20˝ x 1.80˝ with .50˝ NPT Nipple 16˝, 600V Rated UL Listed, UL924, UL916, UL864, C-UL, California State Fire Marshal, CE Plenum, NEMA 1 Yes Yes Coil Current: 30 mA @ 10 Vac 32 mA @ 12 Vac 42 mA @ 24 Vac 50 mA @ 30 Vac 25 mA @ 120 Vac 12 mA @ 10 Vdc 14 mA @ 12 Vdc 16 mA @ 24 Vdc 18 mA @ 30 Vdc Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc Closed Auto Wht/Yel Comm Org Org Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: » Order Normally Closed by adding “-NC˝ to end of model number » Order with Momentary Override Switch by adding “-MNO˝ to end of model number Initial Field Wiring Test Procedure Models that have override test switches are set in the auto position from the factory. This allows emergency power to be switched to the load. To test field wiring connections at the time of installation, the override test switch should be changed to the “closed” position (illuminating emergency lighting) and then placed back to the “auto” position. The red LED shows the normal utility power is connected correctly. Special momentary test switches can be ordered using “-MNO” suffix, which will automatically spring back to the auto position, eliminating the chance to leave the switch in the closed position. Notes Emergency Lighting Emergency Lighting Regular Lighting Bypass / Shunt Relay Shown with Normal Power Energized Emergency Power Emergency Transfer Normal Power Coil Bypass / Shunt Relays ESRU1C ESRH1C ESRU1S ESRH1S ERS2401B ESR2402B ESR2401SB ESR2402SB ESR2401D ESR2402D ESR01P ESR02P ESR24P ESRMU1C ESRMNU1C ESRM2402B ESRM2402SB