MODbreak and MODpower Circuit Breakers

advertisement
MODbreak and MODpower
Circuit Breakers
Your economical power distribution solution
POWER DISTRIBUTION AND PROTECTION
NHP Electrical Engineering Products Pty Ltd
Sales 1300 NHP NHP
Sales 0800 NHP NHP
nhp.com.au
nhp-nz.com
WE’RE easy to do business with
At NHP we’re solely committed to serving the needs of our customers in the industrial electrical industry.
From concept design through to installation and after sales service, we are confident we have the
experience and expertise to exceed your expectations and ensure you get the best result for your project.
How? By combining Partnerships, Agility, Knowledge and Scalability, NHP can offer 100% Australian owned
service that forms the ultimate choice in our industry.
Partnerships:
Agility:
When you choose NHP you gain a valuable industry
partner. You gain access to an exclusive network of quality
global suppliers who, together with NHP, can achieve an
engineered solution for your industrial electrical application.
A partnership with NHP promises to last, working together
with you to offer complete trust, assurance and peace of
mind.
At NHP we understand your project needs and know that
these needs can often change throughout the life cycle of a
project. With a seamless combination of local and technical
support backed by around the clock service and local stock,
NHP has the agility to provide real time solutions where and
when you need them.
Knowledge:
Scalability:
If your industrial electrical application demands a
specialist team of trained project management, design
and engineering professionals, then NHP is the ultimate
choice, bringing together over 40 years of electrical industry
experience and knowledge.
With all the scale of a large multi-national company, NHP
maintain a premium level of customer service and attention to
detail no matter how big or small your project. With over 900+
expert staff in over 50+ branch and regional locations, when you
deal with NHP you receive all of this combined knowledge and
expertise delivered by local people with with a local focus,
backed by global suppliers.
NHP ELECTRICAL ENGINEERING PRODUCTS PTY LTD
Sales 1300 NHP NHP | nhp.com.au |
MODbreak and MODpower
Your economical Power Distribution Solution
NHP are proud to introduce the new MOD series
range of economical power distribution Moulded
Case Circuit Breakers (MCCBs) and Air Circuit Breakers
(ACBs). The MODbreak and MODpower family of
products offer a complete range of circuit breakers
from 20 to 3200 amps and are ideally suited to the
commercial building market as well as contractors
and mechanical services.
The MOD series includes a complete suite of
accessories to complement the range including
remote operation, safety shrouds, off position
padlocking and much more.
MODpower
Ensuring free and easy selectivity software for use
with the MOD series range, NHP has also developed
MODcurve. This software enables customers to
make informed decisions regarding the electrical
protection of their installation from product selection
through to trip settings.
The MOD series also empowers users to upgrade
their circuit breakers to suit their requirements thanks
to the design that offers increased flexibility and easy
customer fit accessories.
MODbreak
3
Moulded Case Circuit Breakers
Range
MB4: 800-1250A
MB3: 400-630A
MB2: 63-250A
Features:
• From 16 A to 1250 A
• MCCBs for distribution systems
• 3 Pole and 4 Pole
• Manual, rotary handle or motorised versions
• Choice of 36kA and 50kA breaking capacities.
• Wide range of internal and external accessories
• Icu = Ics • Chassis options
• With Electronic and Thermal Magnetic protection relays
• Transfer switches and controllers
OCR options
Features of Thermal Magnetic OCR
Features of MTX1 Electronic OCR
• Adjustable overload setting 80% to 100% of ln
• Adjustable magnetic short circuit setting 6 – 10 ln
• Overload protection LT with selectable
inverse time delay
• Push to trip button
• Adjustable Short Time ST characteristic
• True RMS sensing
• Short circuit (ST) characteristic with selectable
time delay
• Infinite adjustment thermal and magnetic dials
• Refer ratings chart for additional setting details
• LT and ST characteristic can be switched OFF
• Fixed instantaneous trip
• DIP switch OCR setting
• Push to trip button
• Thermal memory enable / disable
• Power ON/pick up LED
• Self powered protection
• True RMS sensing
4
Moulded Case Circuit Breakers
Technical advantages
Standard charateristics
Markings & configuration
• Uimp : Impulse withstand voltage
• Ue : Rated operatioal voltage
Removable front terminal cover
• Ucu : Ultimate breaking capacity
• Ucs : Service breaking capacity
CE (european conformity)
• Utilisation category
NHP MCCB type reference
Main contacts position indication
Appliable standards
Operating toggle
Removeable OCR cover
Trip button
Pick-up LED (electronic MCCB’s)
Current rating of MCCB behind cover
Over current release setting
behind cover
Terminal connections behind cover
• Faster tripping
• Low watts loss
The unique speed contact system accelerates the opening of contacts during short circuit. This ensures faster tripping for current limiting.
The entire current carrying path is designed to achieve a very low watt loss
The result-very low let-through, cut-off current and fault clearing time
• Mechanical anti-reclosing
This unique feature ensures that under short circuit conditions, the contacts open and latch even before the release gives a trip command to the mechanism.
• Positive isolation
The MCCB toggle indicates the true position of the main switching contacts
• Double insulation
Internal accessories are housed in insulated casings to ensure a first level of insulation. When the front cover is opened for the fixing of internal accessories, the MCCB is totally insulated ensuring double insulation.
This avoids contact re-closing and bounce
Forward or reverse connection
MODbreak MCCBs can be forward or reverse connected to allow
reversal of line and load connections.
This is especially important for MB and MBC chassis where
MODbreak MCCBs are reverse connected on the chassis as standard.
5
MODbreak Moulded Case Circuit Breakers
Technical data
MCCB Ampere Frames (AF)
MCCB Types
250 A
400A
630A
MB2
MB3
MB3
D
N
Poles
D
N
3 or 4
3 or 4
Thermal magnetic dial adjustment range
Thermal Magnetic & Electronic
0.8 to 1.0 x In and 6 – 10 x Im
MB4
N
N
3 or 4
3 or 4
63, 160, 250, 320, 400
63, 160, 250, 320, 400, 630 A
800, 1000, 1250
Thermal Magnetic & Electronic
0.8 to 1.0 x In and 6 – 10 x Im
Thermal Magnetic & Electronic
0.8 to 1.0 x In and 6 – 10 x Im
Electronic
-
OCR (Over Current Relay) dataOCR (Over Current Relay) data
63, 100, 125, 160, 200, 250
Current Ratings of OCRs (A)
OCR types
D
800/1000/1250
MTX1 Electronic OCR data
OCR adjustments
via DIP switches
Adjustment range (LT)
0.4 to 1.0 in steps of 0.05 or OFF
Adjustment of LT time delay Ir
10s at 6 Ir or 3s at 6 Ir and 10s at 7.2 Ir or 3s at 7.2 Ir
LT Thermal memory
Enable / Disable (θ = ON or 0 = OFF)
Adjustment range (ST) Ir
1.5, 2.5, 4, 5.5, 6.5, 8 x Ir
Short time setting time delay
100ms / Instantaneous or OFF
Fixed Instantaneous OCR setting
10 x In
10 x In
MCCB data
Impulse withstand Voltage (kV)
8
8
8
8
690
690
690
690
750
AS/NZS / IEC / CE 750
AS/NZS / IEC / CE
750
AS/NZS / IEC / CE
750
AS/NZS / IEC /CE
Rated Operational Voltage (V) (max)
Rated Insulation Voltage (V)
Standard and approvals
AS/NZS 60947.2
IEC-60947-2
230 / 240 V AC
400 / 415 V AC
65
36
85
50
65
36
85
50
65
36
85
50
85
50
500 V AC
25
36
25
36
25
36
25
550 V AC
18
25
15
20
15
20
20
IcU
600 V AC
16
18
12
18
12
18
16
kA
690 V AC
10
15
8
15
8
10
10
250VDC (3P in series)
15
25
15
25
15
25
-
500VDC (3P in series) L/ R<15ms
5
10
5
10
5
10
-
100%
100%
100%
100%
100%
100%
100%
Ics as % lcu
Life span
Mechanical
25000
15000
15000
8000
Electrical @1.0 In
10000
4000
2000
750
Operating Frequency (Hz)
50 / 60
Total Opening Time
<10 msec
Finger-proof Terminals
Via use of MB terminal covers
<20 msec
Ambient Temperature
-5°C to + 55°C
Storage Temperature
- 35°C to + 70°C
Mounting Positions
Dimensions
(W x D x H)
Vertical and 90° to the left and right
3 Pole
105 x 96 x 179
140 x 111.5 x 266
140 x 111.5 x 266
210 x 143 x 370
4 Pole
140 x 95 x 179
183.5 x 111.5 x 266
183.5 x 111.5 x 266
278 x 143 x 370
2.5 / 3.3
5.5 / 7.2
6 / 7/.8
13 / 16
3
Weight (kg) (3/4 Pole)
Accessories
Internal
Auxiliary Contact
1C/O or 2C/O
Trip Alarm Contact
1C/O
Auxiliary & Trip Alarm Contact
1C/O + 1C/O
Shunt Release
110 - 415V 50/60Hz, 110 - 220V DC
External
Under Voltage Release
220 - 240 V 50 Hz
Extension handle
3
3
3
Direct mount handle
3
3
3
X
Handle mechanism padlock attachment
3
3
3
3
Captive toggle padlock attachment
3
3
3
3
Mechanical Interlock
3
3
3
X
Motor operator for remote operation
3
3
3
X
Transfer switch controller
3
3
3
3
Spreader bars for MCCB terminals
3
3
3
3
Terminal covers - same width as MCCB
3
3
3
3
Terminal covers - wide width
3
3
3
X
Terminal covers - flush
3
3
3
X
Interpole barriers – c/w with MCCB
3
3
3
3
Chassis rated 800A for 250AF
3
3
3
X
Chassis (high current) up to 2200A
3
3
3
X
MODpower Air Circuit Breakers
Range
MP1-12S
MP1-16S
Features:
• Current rating from 400 A to 4000 A in
3 frames sizes
• Superior safety features - arc chute interlock, smart racking shutter, ready to close contact.
Available in 3 Pole/4 Pole, Manually &
Electrically operated, Fixed / Draw-out
versions
• Modular & snap-fit accessories such as UVT and shunt trip, customise on time scale of
5 mins.
• Common Height & Depth across the range
• Ease of on-site convertibility from Manual
to Electrical operation
• High short time fault withstand capacity, Icu = Ics = Icw for 1 sec for total selectivity
• High mechanical and electrical operating life
• In-built Electrical & Mechanical
Anti-Pumping mechanism
• Complete range conform to IEC 60947-2
• RoHS compliant
• Unique breaker front-facia architecture
displays the electrical accessories equipped on the ACB (with rated control voltage)
• Unipolar, snap-fit control terminals for
independent termination of 2 wires of up
to 2.5 mm each
• ON & OFF buttons can be independently padlocked to prevent unauthorized access
•
Up to 3 breakers can be mechanically inter
locked using bowden cable. The Interlock is
suitable for fixed, draw-out or a combination of MODpower ACB’s
Breaking capacities:
Rated current
1250 A
1600 A
2000 A
2500 A
Frame 1
S: 65kA
MP1-12
MP1-16
MP1-20
MP1-25
Frame 2
S: 65kA
MP2-25
3200 A
MP2-32
7
MODpower Air Circuit Breakers
MTX Over current release
Features:
• Modbus, Profibus & Zigbee communication protocols
• Pluggable communication & power metering • Energy monitoring & control through Energy modules for customisation & enhansed Management system
functionality
• Smart card module for ease of parameterisation
• Dual protection set-groups & password protection
• Protection releases conform to EMI/EMC • Fault indiciation through LED display & pre-trip alarm
standard IEC 62052-11EN
• Trip & event recording query button for last trip record
• Unique O-LED display for wider viewing angle
• Front accessible test port
• Provision for on-load self-diagnosis of releases
Features
Basic protection
Additional protection
Trip Records
Event Records
Smart Card
Communication
Metering
Parameter
Overload - Phase
Overload - Neutral
Short circuit
Directional short circuit
Instantaneous
Earth fault
Current
Voltage
Frequency
Reverse power
Maximum demand
Last 5 trip data
Last 10 event data
Modbus
Profibus
Zigbee (wireless)
Current
% Loading
Voltage
Power & energy
Storable settings (2 sets)
Auxiliary Supply (24 VDC)
MTX 3.5
3
3
3
3
3
3
3
*
*
*
*
3
3
*
*
*
*
3
3
*
*
3
3
* - available as optional. For detailed information please refer MODpower manual
MTX Simulation kit:
• Generates 3 phase current and voltage with adjustable phase angles
• Graphical display & smart GUI with multi functional key operation
• Portable & hand held device to simulate faults
• Dual power ON - battery & external supply
• Auto sensing of connectivity
• Memory card for data storage up to 32 GB
• Stores 10 test records
8
Air Circuit Breakers
Technical data table
Frame
1
Rated uninterrupted current (In) (A)
Version
Rated operational voltage at 50/60 Hz.
400-1600
2000
S
S
Ue
Rated insulation voltage at 50/60 Hz.
Rated Impulse withstand voltage
2
3
2500
400-3200
400-4000
S
S
H
upto 690V
Ui
1000V
Uimp
12kV (Main Circuit)
Suitability for isolation
Yes
Degree of protection on breaker front
IP53 Intrinsic, IP54 available
Pollution degree suitability
3
Utilisation category
B
Compliance
AS/NZS3947-2, IS/IEC 60947 (Part-2), EN60947-2, IEC 60947-2
Rated ultimate S.C.
breaking capacity
Icu (kA)
400/415 V
65
65
65
65
80
500/550 V
55
55
55
55
65
660/690 V
50
50
50
50
55
400/415 V
Rated service S.C.
Breaking capacity
Icu (kA)
500/550 V
100% icu
660/690 V
Rated short time
withstand capacity
Icu (kA)
Rated S.C. making
capacity
Icu (kA)
0.5sec.
65
65
65
65
80
1.0sec.
65
65
65
65
80
3.0sec.
36
36
36
36
50
400/415 V
143
143
143
143
176
500/550 V
121
121
121
121
143
660/690 V
105
105
105
105
121
Opening time (ms)
40
Closing time (ms)
60
Mechanical life
Electrical life
with maintenance
20000
15000
10000
with maintenance
20000
15000
10000
5000
5000
without maintenance
8000
10000
5000
Dimension details:
MODpower offers common depth (421mm) and height (433mm) across the entire range.
Frame
Poles
A (mm)
1
3
347
4
447
3
447
4
581
3
647
4
847
2
3
IP53
9
IS/IEC 60947 - 2, EN 60947- 2,IEC 60947 - 2
Frame
I
I
II
I
III
Software
Overview
MODcurve is a selectivity analysis software package developed by NHP specifically for the Australian
and New Zealand markets. Designed around the MOD series of ACBs and MCBs as well as NHP’s
extensive range of MCBs and fuses, MODcurve presents a user-friendly interface for conducting
selectivity studies.
Features
• Simple and easy to use
• Can be used for coordination with upstream HV fuses
• Includes both MOD6 and Din T ranges of MCBs
• User defined devices can be added
• Ability to print report with single line diagram and circuit breaker settings included
curve
10
MOD series information Available
NHP have a full range of technical documentation for the MOD series available:
Please contact your NHP representative for more information.
CAD blocks
Chassis drawings
Accessories fitting instructions
Upstream
Manuals
MB2 250 DTM MCCBThermal Magnetic 36 kA
MB2 250 NTM MCCBThermal Magnetic 50 kA
Downstream
MOD6 6 kA
MCBs & RCBOs
DIN-T 6 kA
MCBs & RCBOs
Current
rating
≤32
40
50-63
≤32
40
50-63
63 A
100 A
125 A
160 A
250 A
25 / 25
-- / 25
-- / 25
25 / 30
-- / 30
-- / 30
25 / 25
25 / 25
-- / 25
25 / 30
25 / 30
-- / 30
25 / 25
25 / 25
25 / 25
25 / 30
25 / 30
25 / 30
25 / 25
25 / 25
25 / 25
25 / 30
25 / 30
25 / 30
25 / 25
25 / 25
25 / 25
25 / 30
25 / 30
25 / 30
MCCB cascading /selectivity charts
Secondary injection instructions
Wiring diagrams
11
Scan the QR code
to download the
eCatalogues App
AUSTRALIA
New South Wales
Queensland
Sydney
30-34 Day Street North
Silverwater
NSW 2128
Tel +61 2 9748 3444
Brisbane
16 Riverview Place
Murarrie
QLD 4172
Tel +61 7 3909 4999
Melbourne
43-67 River Street
Richmond
VIC 3121
Tel +61 3 9429 2999
Newcastle
575 Maitland Road
Mayfield West
NSW 2304
Tel +61 2 4960 2220
Fax +61 2 4960 2203
Townsville
5 Leyland Street
Garbutt
QLD 4814
Tel +61 7 4779 0700
Fax +61 7 4775 1457
Laverton
104-106
William Angliss Drive
Laverton North
VIC 3026
Tel +61 3 9368 2901
Wollongong
34 Industrial Road
Unanderra
NSW 2526
Tel +61 2 4272 5763
Fax +61 2 4272 5957
Rockhampton
1 Lawson Street
Parkhurst
QLD 4702 Tel +61 7 4927 2277
Fax +61 7 4922 2947
nhp.com.au
SALES 1300 NHP NHP
FAX 1300 NHP FAX
Victoria
Albury / Wodonga
847 Ramsden Drive
Albury
NSW 2640
Tel +61 2 6049 0600
Fax +61 3 6025 0592
Dandenong
40-42 Cyber Loop
Dandenong South
VIC 3175
Tel +61 3 8773 6400
Fax +61 3 8768 8522
Tasmania
Hobart
29B Lampton Ave
Derwent Park
TAS 7009
Tel +61 3 6228 9575
Fax +61 3 6228 9757
Launceston
Unit 3
13-17 Merino Street
Kings Meadows
TAS 7249
Tel +61 3 6345 2600
Fax +61 3 6344 6324
ACT
Canberra
Unit1
187 Gladstone Street
Fyshwick
ACT 2609
Tel +61 2 6280 9888
Fax +61 2 6280 9588
Western Australia
Perth
38 Belmont Ave
Rivervale
WA 6103 Tel +61 8 9277 1777
Northern Territory
Darwin
3 Steele Street
Winnellie
NT 0820
Tel +61 8 8947 2666
Fax +61 8 8947 2049
NHP Electrical Engineering Products Pty Ltd
A.B.N. 84 004 304 812
NMODPOWERACBC 8/13 © Copyright NHP 2013
Toowoomba
Cnr Carroll Street and
Struan Court
QLD 4350
Tel +61 7 4634 4799
Fax +61 7 4633 1796 Cairns
Unit 2
1 Bramp Close
Portsmith
QLD 4870
Tel +61 7 4035 6888
Fax +61 7 4035 6999
South Australia
Adelaide
36-38 Croydon Road
Keswick
SA 5035
Tel +61 8 8297 9055
NEW ZEALAND
nhp-nz.com
SALES 0800 NHP NHP
FAX 0800 FAX NHP
PO Box 62-009
Sylvia Park
Auckland 1644
New Zealand
Auckland
118a Carbine Road
Mt Wellington 1060
Hamilton
78 Rostrevor Street
Hamilton 3204
Napier
126 Taradale Road
Onekawa 4110
New Plymouth
2 Dean Place
Waiwhakaiho 4312
Wellington
52 Victoria Street
Lower Hutt 5010
Christchurch
27 Iversen Terrace
Waltham 8011
Dunedin
30 Fox Street
South Dunedin 9012
Download