Cerberusī Lavatory and Crew Rest Smoke Detection System KTA 2400 D Overview This system has been designed to meet the FAA Rule 14 CFR -- Part 121 -- Airplane Cabin Fire Protection and similar regulations in countries outside of the USA. The KTA 2400 System is QAC 101 (DGAC), AR--514 (CAA) and TSOC1C (FAA) approved and was certified as BFE equipment by Boeing and Mc Donnell Douglas for B737, B747--400 and MD11 aircraft respectively. Each toilet compartment is fitted with an optical smoke detector installed on the ceiling and connected to a control panel generally located in the galley area. Fire Safety Siemens Building Technologies Group Three types of control panels are available: TRA 72--20 with up to 2 channels (2 detectors). TRA 72--60 and TRA 73--60 with up to 6 channels (6 detectors). All these types use the aircraft 28VDC. They are fitted with 2 to 6 alarm indicator lamps, 1 audible alarm (buzzer), 3 pushbuttons: 1 for test of the entire system, 1 for audible alarm cancellation and 1 for reset. Also two 28V/1A alarm outputs are provided on each panel to monitor devices such as cabin attendant call system, a remote lamp in the flight deck, etc. Two Types of Smoke Detectors can be used: FTA 719--01 without provision for a response indicator or FTA 720--01 with provision for a response indicator to be fitted outside the toilet above the door. Both detectors are of the latest generation of optical smoke detectors which introduce the latest technologies in photo--optics and ensure significant reduction of false alarms and enhanced smoke detection. They are installed in the ceiling of each toilet (one detector per toilet). Key features -- The Control Panel is separated from the Smoke Detectors. Hence it can be mounted at any suitable remote location in the aircraft. Most likely in the galley area. -- A complete functional test of the system and its connections can be performed with simple Push to Test button on the Control Panel. -- Clear indication of the alarm / fault locations on the Control Panel. -- The Control Panel is provided with an Alarm Horn (90dB at 1 meter) and a Horn Off Pushbutton. -- Two Alarm outputs are available, one flashing and one steady. -- Cigarette smokers detection. -- Possibility to connect a remote light indicator which may be placed on the outside of the Lavatory / Crew Rest door. -- New generation optical type smoke detectors. -- The KTA 2400 is certified FAA TSOC1C for all civil aircraft types applications. 2 Fire Safety Siemens Building Technologies Group Smoke detection principle LATEST TECHNOLOGIES IN PHOTO--OPTICS AND OPTIMISED LABYRINTH TO AVOID FALSE ALARMS. System schematic 3 Fire Safety Siemens Building Technologies Group TRA 72--60 -- TRA 73--60 6 Channels / 6 Canaux TRA 72--20 2 Channels / 2 Canaux 6 screws on dia. 123 at 60G angle DJ1191 FTA 719--01 FTA 720--01 Dimensions in mm 4 Fire Safety Siemens Building Technologies Group System characteristics Physical Characteristics Electrical Characteristics Dimensions: see figure Weight Control Panel P/N TRA72--20/21 P/N TRA72--60/61 P/N TRA73--60 380g (0.844lbs) 530g (1.177lbs) Smoke Detectors P/N FTA719--01 P/N FTA720--01 265g (0.590lbs) 265g (0.590lbs) Remote Indicator P/N DJ1191 40g (0.088lbs) Power Supply voltage Control Panel Aircraft 28VDC (22 to 32 V) Smoke Detectors 18 to 22VDC supplied by the Control Panel to each detector Remote Indicator 6 VDC supplied by Smoke Detector P/N FTA720--01 Alarm Signals P/N TRA72--20/21 & P/N TRA72--60/61 -- Steady Alarm Output -- Flashing Alarm Output 28V / 1A 28V / 1A (Reset when the “horn off” button is depressed) -- Chime and light indicators P/N TRA73--60 Environmental Characteristics Conform to RTCADO160B (Specific to A330 & A340 Lower Deck Movable Crew Rest) -- SMOKE Output -- DO NOT OPEN HATCH Output -- PTT LD--MCR (Test Signal) Output GND / OC -- 100 mA (to SDCU) 28V / OC -- 1A GND / OC --100 mA (to SDCU) Normal Operating Temperature --15G C + 55G C (+5G F to 131G F) Ground Survival Temperature --55G C to + 85G C (--67G F to 188G F) Normal Operating Pressure 750 to 1059 mbar (10.882 to 15.217 psi) Humidity 95% at 50G C for 6 hours 85% at 38G C for 16 hours 5 Fire Safety Siemens Building Technologies Group Imp. GRAPH 2000 -- Design CL Com Subject to change 6 Fire Safety no. 094530 -- Ind. B Document Siemens Building Technologies Group Edition 05.2003 E Siemens Building Technologies