Data Sheet - Carlton

advertisement
R.3
Baymaster 250/400
High Bay Luminaires
For 150W-400W H.I.D. Lamps or
300W-500W incandescent lamps.
Remote Ballast Mounting
Complete Assembly with Loop Hanger and 3-ft. Cord
Pendant Mounting Complete Assembly
Catalog
NumberQQ
Catalog
Lamp Type________Voltage_____Number©
For High Pressure Sodium Lamps
(complete with ballast)
150W HPS
120-277VQ
150W HPS
480V
G-HB41AL-MT
G-HB41AL-48
For High Pressure Sodium Lamps
(complete with ballast)
250W HPS
120-277VQ
G-HB61AL-MT-RB-3
250W HPS
480V
G-HB61AL-48-RB-3
250W HPS
250W HPS_
120-277VQ
480V
G-HB61AL-MT
G-HB61AL-48
400W HPS
400W HPS
400W HPS
400W HPS
120-277VO
480V
G-HB71AL-MT
G-HB71AL-48
For Metal Halide Lamps (complete with ballast)
250W MH©
120-277VQ
G-HB61AH-MT-RB-3
250W MH©___
480V
G-HB61AH-48-RB-3
Voltage
Lamp Type
For Metal Halide Lamps (complete with ballast)
175W MH©
120-277VQ
G-HB51AH-MT
175W MH©
480V
G-HB51AH-48
250W MH©
250W MH©
120-277VQ
480V
G-HB61AH-MT
G-HB61AH-48
400W MHO
400W MHQ
120-277VO
480V
G-HB71AH-MT
G-HB71AH-48
For Mercury Vapor Lamps (complete with ballast)
250W MV
120-277VQ
G-HB61AM-MT
250W MV
480V
G-HB61AM-48
400W MV
400W MV
G-HB71AM-MT
G-HB71AM-48
120-277VQ
480V
120-277VQ
480V
400 W MHQ
400W MHQ
120-277VO
480V
G-HB71AL-MT-RB-3
G-HB71AL-48-RB-3
G-HB71AH-MT-RB-3
G-HB71AH-48-RB-3
For Mercury Vapor Lamps (complete with ballast)
250W MV
120-277VQ
G-HB61AM-MT-RB-3
250W MV
480V
G-HB61AM-48-RB-3
400W MV
400W MV
120-277VO
480V
G-HB71AM-MT-RB-3
G-HB71AM-48-RB-3
For Incandescent Lamps or H.I.D. lamps and
remote ballast (ballast not included)©
G-H71AM-RB
G-H71AL-RB
G-H71AM-RB
G-H71AM-RB
300W-500W PS-35, incandescent
250W-400W, high pressure sodium
250W, MH.MV©
400W, MH.MVO
O Ballast has primary taps for 120V, 208V, 240V, and 277V.
0 Add suffix E to catalog number if provision for 250W quartz emergency lamp is desired. Furnished with socket installed and pre-wired
(not available on units for remote ballast).
© 250W and 175W MH lamps should be operated in enclosed units only—select enclosing lens from list of accessories.
O 400W MH Lamps: some manufacturers recommend that their lamps be operated in enclosed units only—select enclosing
lens from list of accessories. Contact your lamp distributor or lamp manufacturer for the latest safety information.
© Ballast cannot be located more than 20 feet from fixture when HPS lamps are used.
0 To order fixture complete with lamp, add suffix -L to catalog number.
TO ORDER ACCESSORIES, REFER TO PAGE 4. TO ORDER FIXTURE WITHOUT REFLECTOR, CHANGE "A" TO "1" IN FIXTURE
CATALOG NUMBER. TO ORDER REFLECTOR ONLY, USE CAT. NO. G-7AW
Electrical Specifications All ballasts are C.W.A type, except 150W HPS which is HX-Auto
Line
Volts
Start.
Amps
Oper.
Amps
Total
Watts
1 SOW High Pressure Sodium
120
208
240
277
480
1.80
1 .05
0.90
0.76
0.46
1.80
1.00
0.90
0.80
0.45
1.90
1 .20
1 .00
0.90
0.60
2.60
1.50
1.30
1.15
0.70
Start.
Amps
Oper.
Amps
Total
Watts
Line
Volts
Start
Amps
Oper.
Amps
400W High Pressure Sodium
250W Metal Halide
188
120
2.50
188
;208
1.50
188
188
188
:240
J277
480
1.25
1.10
0.50
475
475
475
475
475
120
208
240
277
480
205
205
205
'120
208
240
250W High Pressure Sodium
120
208
240
277
480
Line
Volts
295
295
295
295
295
4.60
2.60
2.30
2.00
1.00
175W Metal Halide
!120
!208
'240
S277
I480
1.10
0.64
0.55
0.48
0.22
1.80
1.10
0.90
0.78
0.45
1.62
0.95
0.82
0.71
0.40
2.52
1.46
1.26
1.10
0.63
Total
Watts
Line
Volts
295
295
295
295
295
120
208
240
277
480
205
210
277
1 480
1.45
0.81
4.00
2.30
2.00
1.70
1.00
460
460
460
460
460
120
208
: 240
;
277
|480
Oper.
Amps
Total
Watts
250W Mercury Vapor
2.35
1 .43
1 .09
0.94
0.48
2.54
1.51
1.25
1.07
0.61
290
290
290
290
290
400W Mercury Vapor
400W Metal Halide
3.00
1 .90
1 .70
Start.
Amps
300
1 .70
1 .50
1.30
0.77
3.80
2.20
1.90
1.65
0.95
450
450
450
450
450
Refer to Pricing Index for price,
weight, and standard package
Copyright 1991 Printed in U.S.A.
m ^ •ELECTRIC COMPANY
Effective Oct. 1991, PAGE 3
R-2
Baymaster 250/400
High Bay Luminaires
For 150W, 250W or 400W HPS Lamps, 175W, 250W or 400W MH
Lamps, 250W or 400W MV Lamps, or 300W-500W incandescent
lamps.
Applications
• For illumination of manufacturing,
storage, and other indoor areas.
Features
• Standard Baymaster fixtures operate
in high ambient temperatures. All units
suitable for minimum 90°C supply wire.
• High efficiency (up to 78% with 250W
HPS lamps) with exceptionally long lamp
life—economical to own and operate.
• Pre-wired, integral ballasted, with
multi-tap primary for 120, 208, 240, or
277 volt lines or with 480 volt primary.
Ballasts are highest quality, Class H
insulated, U.L. listed C.W.A. types,
thermally isolated for cooler operation
and long life. Grounding wire provided.
• Ballast housing is finned, die-cast
copper-free aluminum, finished with
corrosion resistant powder-coat white
polyester.
• Sockets are heavy duty porcelain
mogul base, with spring loaded, nickel
plated center contact and heavy gauge,
nickel plated brass screw shell with
double lamp grips to prevent lamps
from loosening due to vibration.
• Efficient, low glare, compact reflector is exceptionally rugged, heavy gauge
Alzak® finished aluminum.
• Reflector installs and adjusts to wide,
medium, or narrow distribution (without tools) by repositioning stainless
steel spring locks.
• Installation is quick and easy: (1)
mount junction box to 3/4" conduit, (2)
slide ballast onto junction box, (3) make
connections, (4) install lamp, (5) snap
reflector in place.
• Open-top reflector design keeps reflector clean because of thermal barrier and chimney effect, and provides
up-light to relieve contrast.
Options
• All units available with a sensor circuit for automatically lighting an auxiliary safety lamp if a power dip or lamp
failure extinguishes the HID lamp.
Compliances
• Ul. Listed, UL Standard 1572,
Damp locations.
Suitable for Minimum
90°C Supply Wire
Spring Position
Upper: 24-3/8"
Center: 25-3/8"
Lower: 26-5/8"
Luminaire Performance
150 Watt
Effic. S.M.H.f
Distribution*
175 Wan
I
250 Watt
Effic. S./M.H.f Effic. S./M.H/t
400 Watt
Effic. S./M.H.t
High Pressure Sodium
Narrow
Medium
Wide
71 0%
72 1%
73 2%
.8:1
—
—
80.0%
1.5:1
—
—
—
77.5%
74.6%
.6:1
1.4:1
2.5:1
80.0%
77.6%
75.4%
2.5:1
.8:1
1.8:1
2.4:1
82.9%
82.8%
80.4%
.8:1
1.8:1
2.4:1
79.6%
77.2%
75.2%
2:1
2.7:1
71.3%
1:1
70.8% 1.3:1
70.1% 1.8:1
78.2%
76.4%
75.6%
1.3:1
1.7:1
k.0:1
2.5:1
.6:1
1.4:1
1
al Halide
Narrow
Medium
Wide
—
—
—
82.9%
82.8%
80.4%
1:1
Mar«*iiru Vartm*
Narrow
Medium
Wide
«Reflector adjusts for Narrow to Medium to Wide distribution without tbols.
tS./M.H.: Spacing to Mounting Height.
• Standard Baymaster fixtures operate efficiently in high ambient temperatures.
•65°C max. ambient temp, for 150W-250W H.P.S. (G-HB41AL-MT, G-HB41AL-48,
G-HB61AL-MT, G-HB61AL-48); 175W-250W MH (G-HB51AH-MT, G-HB51AH-48,
G-HB61AH-MT and G-HB61AH-48); 250W MV (G-HB61AM-MT and G-HB61AM-48).
•55°C max. ambient temp. 400W HPS (G-HB71AL-MT, G-HB71AL-48); 400W MH
(G-HB71AH-MT, G-HB71AH-48); 400W MV (G-HB71AM-MT, G-HB71AM-48).
i)Appletori
PAGE 2, Effective Oct. 1991
Remote Ballast
Mounting
Pendant Mounting
>-^/
•
IELECTWC COMPANY
1701 W. Wellington Ave.
Chicago, Illinois 60657
Copyright 1991 Printed in U.S.A.
Download