LED Elevated Taxiway Edge Light LVC03 Compliances: ICAO: Annex 14 - Volume I FAA : L-861T AC150/5345-46 (Current Edition) and Engineering Brief No.67 IEC: TS 61827 NATO: STANAG 3316 Manual: Instruction Manual UT-MT-0689 Performances and benefits: Designed to replace the existing halogen and incandescent elevated taxiway edge fixtures. Daytime recognition thanks to the blue locking ring of the glass. Thanks to the long life of the LED (60,000 hours at the top brightness step or far over 100,000 hours in normal operating conditions) the maintenance activities are extremely reduced and the safety of the airport opre ations is considerably increased. The LED emission directly ensures the correct r.colou Coloured filters are not required, therefore no colour shifts are noted when viewed at various angles or under temperature/current variations. The optional arctic k,it thermostatically controlled, prevents ice and snow build-up like a traditional fixture. The compatibility with the existing typical AFL series circuits is complete. There is no need to replace CCRs, transformers and cables. The electronics inside makes the light output variable like a traditional haloge n lamp, as indicated by the FAA “Engineering Brief No.67”. The lights are provided with a surge protection device, as required by the FAA “Engineering Brief No.67”. The possibility of installation on existing base plates, stakes or elbows gives the possibility of a progressive replacement of the existing lights. A new installation with LED lights means lower loads and therefore low-sized CCRs and transformers, thus allo wing significant savings on installation and management . Features: Low profile design to reduce jet blast damage. The body is balanced on the slipfitter through treelevelling screws. Adjustable height. Standard with G 2” breakable coupling, but availabl e with 1”1/2 - 12 UNF one and 2” - 11 1/2 NPS one on request. Lens with external smooth surface to prevent dirt deposit. The lens is mechanically secured to the body byalmet threaded ring with flat gasket. Replacement is quick and easy. No optical adjustment is required after the replace ment of LED or lens. Fixture energy consumption: typically 4 VA. Arctic kit consumption: less than 10 VA. How To Order: LVC 03 - I - 55 - 25 - C - 0 - 02 Basic P/N: Version: Compliance: I = ICAO – IEC S = STANAG F = FAA Mode: 5 = 2.8-6.6A Power Supply Power: 5 = 50 Hz current driven 6 = 60 Hz current driven Height (installed on a pipe elbow): 25 = 250 mm 28 = 280 mm 32 = 320 mm 35 = 350 mm Breakable coupling: A = 1”1/2 - 12 UNF B = 2” - 11 1/2 NPS C = 2“ Gas Arctic kit: 0 = without arctic kit 1 = with arctic kit Monitoring: 01 = with monitoring 02 = without monitoring Photometric distribution: Luminous Sources: One blue LED Dedicated optics to collect the LED luminous flux a nd maximize the light output. Electronics: Internally mounted, protected against water and de- icing agents. Strong-built, highly resistant to shock and vibration. GOLLAND Sp. z o.o. www.oswietlenielotniskowe.pl ul. StyczyĆskiego 83 41-500 Chorzów tel. +48 32 349 17 00, +48 32 349 17 01, fax +48 32 349 17 02 UC-PU-0215 Rev.B e-mail: centrala@golland.pl Light output variable like a traditional halogen lamp , as indicated by the FAA “Engineering Brief No.67”. Power Supply: 10/15 W isolation transformer for series circuitsS.tandard 30/45 W isolation transformer may also be used. 250 mm 250 mm Typical installation: Installation on pipe elbow Installation on a deep base Accessories: [P/N] Description 013.0008 Galvanized steel pipe elbow with upper threaded end only (2” - 11 GAS thread) Galvanized steel pipe elbow with both threaded ends (2” - 11 GAS thread) Set of two nylon rings for receptacle supp ort inside pipe elbow 315.3210 013.0010 315.1228 315.1062 315.1065 315.1072 332.3500 Base L-867, Class I A, Size B, 24” Deep Baseplate for L-867 base with gasket and cable clamp (2”-11 GAS thread) Baseplate for L-867 base with gasket and cable clamp (2” - 11 1/2 NPS thread) Baseplate for L-867 base with gasket and cable clamp (1”1/2 - 12 UNF thread) Levelling device For any information about isolating transformers and connectors, please see the specific catalogue pages . Renewal Parts: [N°] Description 1 2 3a 3b 3c 4 5 6 Shipping Weights and Volumes: Light Unit, 250 mm height Weight (kg) Package Dimension (cm) Volume (m3 ) GOLLAND Sp. z o.o. www.oswietlenielotniskowe.pl 1.3 26 x 12.5 x 13.5 0.004 7 8 9 10 11 12 13 [P/N] 300 mm Cable leads with plug ........................ ...... 323.2220 Fixture grounding wire......................................... 156.5400 Breakable coupling, 1”1/2 - 12 UNF thread............ 001.2062 Breakable coupling, 2” - 11 ½ NPS thread.............. 156.5420 Breakable coupling, 2” - 11 GAS thread .................. 156.5490 Standard 1-inch tube........................................... 315.3810 Fixture body ........................................................ 156.5480 PCB, 50Hz, light w/o arctic kit and monitoring........156.5500 PCB, 50Hz, light w/o arctic kit, with monito.r.i.n..g...... 156.5506 PCB, 50 Hz, light with arctic kit, w/o monito..r.i.n..g.... 156.5501 PCB, 50 Hz, lightwith artic kit and monit .............. 156.5507 PCB, 60Hz, light w/o arctic kit and monitoring.........1..5.6.5509 PCB, 60Hz, light w/o arctic kit, with monito.r.i.n..g...... 156.5508 PCB, 60 Hz, light with arctic kit, w/o monitorin...... g156.5510 PCB, 60 Hz, lightwith artic kit and monit .............. 156.5503 LED assembly........................................................... 150.3926 Gasket for lens .......................................................... 325.0480 Lens.......................................................................... 317.4340 Lens locking ring ..................................................... 303.0370 Cable gland............................................................. 001.2172 Arctic kit thermostat.............................................. 156.5512 Arctic kit heater .................................................... 156.5513 ul. StyczyĆskiego 83 41-500 Chorzów tel. +48 32 349 17 00, +48 32 349 17 01, fax +48 32 349 17 02 e-mail: centrala@golland.pl