TALGIL COMPUTING & CONTROL LTD. P.O.B. 775 Kiryat Motzkin 26119 ISRAEL Tel: 972-4-8775948 Fax: 972-4-8775949 E-mail : talgil33@netvision.net.il USER GUIDE The frost protection controller is specially designed to protect the crops and the hydraulic systems from being affected by low temperature. An analog temperature sensor connected to the unit, enables continuous reading of the temperature between -10 and 60 Cº with a resolution of 0.5 Cº. When the ambient temperature drops below the predefined set-point Ton the irrigation is started and it will continue until the temperature raises above the second set-point Toff at which the irrigation stops. When logically defined, the relation Toff >Ton is expected, but even if by mistake the relation is inversely defined, the system will still execute the frost protection referring to Ton as the set-point, below which the irrigation is active and above which it is stopped. The controller needs no external powering, it is powered by two 9 Volt Alkaline batteries and it activates two wired 12v DC latching solenoid. Alternatively, if for some reason the analog sensor can not be used, a dry contact thermostat can be utilized. The system reports the currently measured temperature, the battery voltage, the current status, the number of activations by the sensor and it also detects and informs about various kinds of malfunctions. THE CONTROL PANEL The unit is equipped with an LCD display and two arrow keys. For energy saving purposes the screen shuts off when the keys are not being used for more than a minute. Hitting any of the arrow keys, turns the screen on again after a delay that may take 8 seconds. The main screen displays the ACTUAL temperature and the two set-points Ton and Toff that can be changed by the user. Ton 01.0 ACTUAL 15.5 Toff 02.5 USING THE ARROW KEYS Use the left arrow key to move from one screen to another In order to change the set-points Ton and Toff, the right arrow key has to be used. At the first touch, the cursor ▓ appears, blinking on the leftmost digit, which can now be changed by using the left arrow. Use the right arrow again to move to the next digit to be changed. HALTING AUTOMATIC ACTIVITY The system can be directed to halt automatic activity and to go into "FREEZE" state in which the process will not start even if the actual temperature is below Ton. The actual temperature will be displayed as usual and manual opening and closing of the solenoid is allowed. For entering the "FREEZE" state and for exiting the FREEZE state, push both the arrow keys simultaneously. MANUAL ACTIVATION The manual activation is intended for testing the solenoid. The Manual activation button is located at the left side of the terminal board, see the drawing below. Keep the button pushed and after a while, the solenoid will be activated. It will remain activated as long as the button is pushed. Release the button and after a few seconds the solenoid will shut down. USING DRY CONTACT THERMOSTAT Optionally a dry contact Thermostat can be used in place of the analog temperature sensor. It has to be connected to the terminals marked "CONT. IN" see drawing below. A few seconds after sensing closed contact the process will start and it will remain active as long as the contact remains closed. Manual activation Analog sensor input + IN GND Two wired DC Latching solenoid NO- Black Green NC- Green Black Connection of the analog sensor to the FROST FROST Analog temperature sensor + IN GND +18 v OUT GND A three wired cable up to a distance of 30 meters makes the connection. Dry contact input for thermostat Analog temperature sensor