REDUNDANT POWER SERIES
The ICT N+1 Redundant Power System is the solution to your critical power needs. True redundancy means that if
module failure occurs, the other modules will continue to supply power. ICT’s N+1 systems are available from 35 to 140
amps depending on the output voltage selected. They are manually switchable between 120 and 220 VAC input voltages
and are available in 13.8 and 27.6 VDC output voltages. They come standard with battery back-up terminals and system
monitoring functions through a Dsub connector, such as module ok, overtemperature warning, analog DC output current,
fan failure, and AC fail. Wallmount brackets and a rackmount adapter are included with each N+1 system.
ICT22012-100N
SPECIFICATIONS (12volt system)
70 AMP
100 AMP
140 AMP
SYSTEM
ICT22012-70N
ICT22012-100N
ICT22012-140N
INPUT VOLTAGE RANGE (120)
INPUT VOLTAGE RANGE (220)
OUTPUT VOLTAGE
NUMBER OF MODULES
OUTPUT CURRENT(CONTINUOUS)
OUTPUT CURRENT(PEAK)
CURRENT LIMITING
LINE REGULATION
LOAD REGULATION
OUTPUT RIPPLE (MAX)
EFFICIENCY
OPERATING TEMPERATURE
SIZE (LxWxH)
WEIGHT
105 VAC - 130 VAC
205 VAC - 250 VAC
13.8 VDC+/- 150 mV
2
33.0 + 33.0 redundant AMPS
35.0 + 35.0 redundant AMPS
80.0 AMPS
1% (100-130 VAC)
1% (0.5-33.0 AMPS)
40 mV RMS
80% (MIN)
-50 to +125 degrees F
19 X 11.1 X 3.5 inches
14.0 lbs
105 VAC - 130 VAC
205 VAC - 250 VAC
13.8 VDC+/- 150 mV
3
65.0 + 35.0 redundant AMPS
70.0 + 35.0 redundant AMPS
120.0 AMPS
1% (100-130 VAC)
1% (0.5-65.0 AMPS)
40 mV RMS
80% (MIN)
-50 to +125 degrees F
19 X 11.1 X 3.5 inches
16.0 lbs
105 VAC - 130 VAC
205 VAC - 250 VAC
13.8 VDC+/- 150 mV
4
90.0 + 35.0 redundant AMPS
92.0 + 35.0 redundant AMPS
160.0 AMPS
1% (100-130 VAC)
1% (0.5-90.0 AMPS)
40 mV RMS
80% (MIN)
-50 to +125 degrees F
19 X 11.1 X 3.5 inches
18.0 lbs
Redundant Power Supplies
redundant power series
SPECIFICATIONS (24volt system)
35 AMP
50 AMP
70 AMP
SYSTEM
ICT22024-35N
ICT22024-50N
ICT22024-70N
INPUT VOLTAGE RANGE (120)
INPUT VOLTAGE RANGE (220)
OUTPUT VOLTAGE
NUMBER OF MODULES
OUTPUT CURRENT (CONTINUOUS)
OUTPUT CURRENT (PEAK)
CURRENT LIMITING
LINE REGULATION
LOAD REGULATION
OUTPUT RIPPLE (MAX)
EFFICIENCY
OPERATING TEMPERATURE
SIZE (LxWxH)
WEIGHT
105 VAC - 130 VAC
205 VAC - 250 VAC
27.6 VDC+/- 300 mV
2
17.0 + 17.0 redundant AMPS
18.0 + 18.0 redundant AMPS
40 AMPS
1% (100-130 VAC)
1% (0.5-17.0 AMPS)
40 mV RMS
80% (MIN)
-50 to +125 degrees F
19 X 11.1 X 3.5 inches
14.0 lbs
105 VAC - 130 VAC
205 VAC - 250 VAC
27.6 VDC+/- 300 mV
3
34.0 + 17.0 redundant AMPS
36.0 + 18.0 redundant AMPS
60 AMPS
1% (100-130 VAC)
1% (0.5-34.0 AMPS)
40 mV RMS
80% (MIN)
-50 to +125 degrees F
19 X 11.1 X 3.5 inches
16.0 lbs
105 VAC - 130 VAC
205 VAC - 250 VAC
27.6 VDC+/- 300 mV
4
44.0 + 17.0 redundant AMPS
45.0 + 18.0 redundant AMPS
80 AMPS
1% (100-130 VAC)
1% (0.5-44.0 AMPS)
40 mV RMS
80% (MIN)
-50 to +125 degrees F
19 X 11.1 X 3.5 inches
18.0 lbs
SPECIFICATIONS (spare module only)
- true redundancy
- 120 to 220 VAC manual switch
- quick swap modules
- system status monitoring
- high efficiency
- double-sided circuit boards
- precise load sharing
- redundant or-ing diode
▲
FEATURES
12VDC/30 AMP
24VDC/17 AMP
MODULE ONLY
ICT12-30N
ICT24-17N
INPUT VOLTAGE RANGE (120)
INPUT VOLTAGE RANGE (220)
OUTPUT VOLTAGE
OUTPUT CURRENT (CONTINUOUS)
OUTPUT CURRENT (PEAK)
CURRENT LIMITING
LINE REGULATION
LOAD REGULATION
OUTPUT RIPPLE(MAX)
EFFICIENCY
OPERATING TEMPERATURE
SIZE (LxWxH)
WEIGHT
105 VAC - 130 VAC
205 VAC - 250 VAC
13.8 VDC
32.5 A
35.0 A
36.0 A
1% (100-130 Vac)
1% (0.5-32.5 AMPS)
35 mV RMS
80% (MIN)
-50 to +125 degrees F
8.5 X 4.0 X 2.6 inches
2.0 lbs
105 VAC - 130 VAC
205 VAC - 250 VAC
27.6 VDC
17.5 A
18.5 A
19.0 A
1% (100-130 Vac)
1% (0.5-17.5 AMPS)
35 mV RMS
80% (MIN)
-50 to +125 degrees F
8.5 X 4.0 X 2.6 inches
2.0 lbs
11