BG2 Range - MANUAL CALL POINT Exed, Intrinsically Safe (Exia), Weatherproof Features ᔢ Zone 0, Zone 1 and Zone 2 use. ᔢ Exed, Exia or weatherproof. ᔢ ATEX approved – Ex II 1G (Exia) – Ex II 2G (Exed) ᔢ BASEEFA certified. ᔢ IP66 and IP67. ᔢ Certified temperature: –40°C to +50°C*. ᔢ Corrosion resistant red painted GRP. ᔢ Retained stainless steel cover screws. ᔢ Optional lift flap. ᔢ Key operated test facility. ᔢ Lightweight and robust. ᔢ Breakglass hammer available. (Contact sales office for details) *Depending on version. Introduction This manual fire alarm call point has been designed for use in flammable atmospheres and harsh environmental conditions. The GRP enclosure is suitable for use offshore or onshore where lightweight combined with a high level of corrosion resistance is required. Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK. Sales Enq. UK: +44 (0)1773 864 100 Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA Sales Enq. USA: +1 (713) 937- 9772 E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com 6DS029/L Specification Protection: Certification: BG2W BG2E BG2I Dust-tight and Weatherproof Explosion Protected Exed (Increased Safety) Explosion Protected Exia (Intrinsically Safe) Not Applicable CENELEC EN50014, 018, 019, 028 Cert. No. BAS02ATEX2105X ExedIICT6 (switch only) ExedmIICT4 (other versions) Suitable for use in Zones 1 & 2 American Bureau of Shipping Type Approval CENELEC EN50014, 020 Cert. No. Baseefa03ATEX0084X Exia IIC T4 Suitable for use in Zones 0, 1 & 2 Up to 254V Up to 250V (Switch only) Up to 24V (Resistors & Switch) Up to 28V (IS) –40°C to +55°C –20°C to +50°C –40°C to +50°C IP66 & 67. IP66 & 67. IP66 & 67. BS 5839 : Part 2 : 1983 (BG). BS 5839 : Part 2 : 1983 (BG). BS 5839 : Part 2 : 1983 (BG). Voltage: Certified Temperature: Ingress Protection: British Standard for Call Points: Switch Ratings: Resistor Values: d.c.: 0-30V 5A (resistive) or 3A (inductive) 30V-50V 1A resistive or inductive a.c.: 0-254V 5A resistive or inductive 100R Minimum* NOT APPLICABLE 100R Minimum, 39k Maximum* Cable Enries: 470R Minimum* 2 x M20 bottom. 6 x 2.5mm2 Terminals: 6 x 2.5mm2 6 x 2.5mm2 Weight: 1.2 Kg. Material: U.V. resistant glass reinforced polyester. Finish: Painted Red 1. Switch Only 2. End of Line Resistor / Diode R1/D1 1 2 3 4 5 6 1 2 3 4 5 6 ALL CIRCUITS SHOWN WITH GLASS INTACT 3. In Line Resistor / Diode 4. In Line & End of Line Resistor / Diode R1/D1 R2/D2 R2/D2 1 2 3 4 5 6 1 2 3 4 5 6 ALL DIMENSIONS IN MILLIMETERS Ordering Requirements The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. For standard products, available ex-stock, contact sales office for details. Model The MEDC BG Range of Manual Alarm Call Points caters for numerous options such as variety of colours, LED indication, earth continuity, double switch, etc. See separate catalogue sheet for details. Model BG2W – a.c. or d.c. BG2I – Up to 28V (I.S.) BG2E – d.c. BG2E – a.c. Options Code BG2WNN BG2INN BG2EDC BG2EAC Options Code Switch only 1 End of line resistor 2* In line resistor 3* In line and end of line resistor 4* 5 Diode (specify location & value) Flap Flap Fitted Not Fitted Finish Code F* N Finish Red Painted Code R * Polycarbonate lift flap. * Specify resistor values. All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. 02/12 BG3 Range - MANUAL CALL POINT Intrinsically Safe (Exia), Weatherproof Features ᔢ Zone 0, Zone 1 and Zone 2 use. ᔢ Exia IIC T4. ᔢ ATEX Approved Ex II 1 G. ᔢ BASEEFA certified. ᔢ Chinese (CQST) certified. ᔢ Designed in accordance with EN54-11. ᔢ IP66 and IP67. ᔢ Certified temperature: –55°C to +55°C. ᔢ Corrosion free GRP. ᔢ Optional in line/end of line resistors/diodes. ᔢ Optional LED indicator. ᔢ Optional lift flap. ᔢ Key operated test facility. ᔢ Various body colours available. Introduction This manual fire alarm call point has been designed in accordance with the latest draft European Call Point Standard (EN54-11). Weatherproof to IP66 and IP67 and available certified intrinsically safe, simple apparatus or uncertified. The units are manufactured from glass reinforced polyester (GRP) which provides a robust, corrosion free construction and ensures effective and reliable operation in harsh industrial and offshore environments. Units are supplied in natural red GRP or painted to customer specification. 'Burning House' duty label is provided as standard, other duty and tag labels may be supplied to customer specification. Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK. Sales Enq. UK: +44 (0)1773 864 100 Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA Sales Enq. USA: +1 (713) 937- 9772 E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com 6DS100/M Specification Protection: Certification: BG3I BG3W Explosion Protected Exi (Intrinsically Safe) Dust-tight & Weatherproof CENELEC EN50014, 020 BASEEFA Exia IIC T4 Cert No. BAS00ATEX1067X Suitable for use in Zones 0, 1 & 2 Chinese Certification CQST – Exia IIC T4† Not applicable Voltage: Certified Temperature: Up to 28V (IS) Up to 250V a.c. -55°C to +55°C Not applicable IP66 & IP67 IP66 & IP67 Ingress protection: European Standard for Call Points: EN54-11 EN54-11 6 x 4.0mm2 6 x 4.0mm2 Not Applicable d.c. 0V - 30V 3A resistive or inductive 30V - 50V 1A resistive or inductive a.c. 0 - 250V 3A resistive or inductive Terminals: Switch Ratings: Resistor Values: Cable Entries: 470R Minimum 270R Minimum 2 x M20 top or bottom 2 x M20 top or bottom Weight: 0.5Kg 0.5Kg Material: UV resistant glass reinforced polyester UV resistant glass reinforced polyester Natural Red GRP or Painted GRP to Customer requirements Natural Red GRP or Painted GRP to Customer requirements Stainless steel as standard Plastic as standard Finish: Duty/Tag Labels: ALL DIMENSIONS IN MILLIMETERS Ordering Requirements The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Standard products available ex-stock. Please visit www.coopermedc.com for further details. Model Labels Certification Options Entries Finish BG3 Certification Weatherproof Exia Chinese (CQST) Code W I Q† † Not suitable for use in China on fire alarm systems. Label Code Glass Label Fire Break Glass 'Press Here' 1 Break Glass 'Press Here' 2 Special 3* European Standard 4 Duty Label (special) 5* Burning House as standard Tag Label 6* Options None Resistor Series Resistor EOL Diode Polycarbonate Lift flap Stainless steel Lift flap LED Double Changeover Plastic Element Code N S* E* D F C L T P Entries 2 x M20 (bottom) 2 x M20 (top) Code B T For blanking plugs add “P’ to code. e.g. BP, 2 x M20 bottom entries with one blanking plug. Finish Natural Red Blue Green White Yellow Special Code R B G W Y S* * Please specify (replaces break glass) * Specify wording * Please specify All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. 02/12 MANUAL CALL POINTS Exed, Intrinsically Safe (Exia), Weatherproof BG Range & PB Range Features ᔢ Polyester enclosure – light, strong and not subject to corrosion. ᔢ 2 models: Breakglass. Pushbutton. ᔢ 4 basic versions available: (1) Explosion protected Exe (ATEX, Chinese [CQST],Brazilian [Inmetro]) (2) Explosion protected Exi (ATEX, GOST ‘R’, GOST ‘K’, Chinese (CQST), Brazilian [Inmetro] or CSA), (3) Explosion protected: Class I, Div. 2, Groups A-D Class II, Div. 2, Groups F & G (PB only) Class I, Zone 2 (4) Weatherproof & Dust-tight/UL ordinary locations. ᔢ In line and end of line resistors and/or zener diodes can be fitted. ᔢ Variety of colours available. ᔢ Up to 9 terminals available. ᔢ Lift flap available for extra protection against inadvertent operation. Introduction These manual fire alarm call points have been designed for use in hazardous locations and harsh environmental conditions. The GRP enclosures are suitable for use offshore or onshore, where lightweight combined with a high level of corrosion resistance is required. ᔢ Optional LED – this indicates that the unit has been operated – useful for testing purposes. ᔢ Earth continuity option for metal glands. ᔢ 1 or 2 changeover switches. ᔢ Captive cover screws. ᔢ SIL 2 Certified. Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK. Sales Enq. UK: +44 (0)1773 864 100 Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA Sales Enq. USA: +1 (713) 937- 9772 E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com 6DS067/S Features Breakglass Model ᔢ No hammer required – the glass is covered by a membrane thus protecting the operator from glass fragments. ᔢ A plastic ‘Break glass’ or deformable operating element is available to replace the break glass*. Once the flexible element is pressed it bends but will not break. The unit is reset by repositioning the element. All other functions remain the same. ᔢ Complies with the British Standard for call points. ᔢ Key operated test facility – simple but secure. ᔢ Breakglass hammer available. Pushbutton Model ᔢ Stayput as standard or self reset available. ᔢ Lift Flap as standard. (Not turn and push model). *Note: Deformable operating element does not comply with BS5839 Part 2. Specification Model: BGW & PBW Protection: Weatherproof/ dust proof Certification: Weatherproof/ dust proof BGE & PBE BGI & PBI Explosion Protected Class I, Div 2 Class II, Div 2 Explosion Protected Exed (Increased Safety) Explosion Protected Exia (Intrinsically Safe) UL Listed to Class I, Div 2, Groups A-D BGUL & PBUL Class II, Div 2, Groups F & G (PBUL only) Listing No. E186629 ATEX approved Ex II 2GD BAS02ATEX2105X (PB only) ATEX approved Ex II 1GD Baseefa 03ATEX0084X (PB only) ATEX approved Ex II 1G Baseefa 03ATEX0084X (BG only) *BGUL & PBUL IP66/IP67 ATEX approved Ex II 2G BAS02ATEX2105X (BG only) Exia IIC T4 CENELEC EN50014 CENELEC EN50020 Suitable for use in Zones 0, 1 & 2 Exed IICT6 (switch only) Exedm IICT4 (other versions) CENELEC EN50014 EN50019 EN50018 EN50028 Suitable for use in Zones 1 & 2 UL listed for ordinary locations Listing No. S8117 *Refer to UL data sheet at rear of catalogue for complete information Chinese Certification (PBE & BGE):† CQST – Exed IIC T6 (switch only) Exedm IIC T4 (other versions) GOST ‘R’ Certification (PBE & BGE): Exedm IIC T6 Exedm IIC T4 (other versions) Russian Fire Approved Brazilian (Inmetro) Certification: BR-Ex emd IIC T4 or BR-Ex ed IIC T6 CSA Certification to C22.2 (PBI only): Nos.0-M, 0.4-M, 14-M, 25, 30-M, 94, 142-M1987, 157-M1987, 157-92, Enclosure Type 4. T4A Class I Groups A, B, C & D Cert. No. 79120 GOST ‘R’ Certification (PBI & BGI): Exia IIC T4 Russian Fire Approved GOST ‘K’ Certification (PBI only): Exia IIC T4 SIL 2 Certification to 61508. Cert. No. Sira 11013 (BGE only). Chinese Certification (PBI & BGI): CQST – Exia IIC T4 American Bureau of Shipping Type Approval BGE only Brazilian (Inmetro) Certification: BR-Ex ia IIC T4 American Bureau of Shipping Type Approval Voltage: Certified Temp: Up to 254V Up to 240V –40°C to +55°C Weatherproof –25°C to +55°C (PBUL) –25°C to +55°C (BGUL) Switch Ratings: (1 or 2 changeover switches fitted) Up to 250V Up to 28V (IS) –20°C to +50°C ATEX/CENELEC –40°C to +70°C (PBI) ATEX/CENELEC –40°C to +50°C (BGI) UL Version CSA –50°C to +40°C (PBI only) d.c. - 0-30v 5A (resistive) or 3A (inductive) 30-50 1A resistive or inductive a.c. - 0-254V 5A resistive or inductive NOT APPLICABLE Note: UL versions Max Rating 240VAC, 3A Material: Anti static U.V. resistant glass reinforced polyester. Finish: Red painted finish as standard or to Customer specification. British Standard for Call Points: BS 5839 : Part 2 : 1983 (BG). Weight: 1.2 kg. (Varies with model & entries). Ingress Protection: IP66 & IP67. Entries: Up to 4 entries, M16 or M20 top and bottom (1/2" NPT available on UL version). Terminals: 6 x 2.5mm2 – standard (BGUL only). 7 x 2.5mm2 – standard. 9 x 2.5mm2 optional – up to 60V only. Risistors & Diodest: Various configurations available on versions up to 24V and all "IS" versions. (Minimum Resistor value 100ΩPBE/BGE, 470ΩPBI/BGI). Earth Continuity: Internal & external earth continuity is provided via an optional earth plate. LED Indication: A high intensity red LED can be fitted as an optional extra to indicate operation on versions up to 24V and all "IS" versions. Labels: BG Glass label - reads either (1) Fire Break glass – press here (2) Break glass – press here (3) Worded to customer requirements. PB & BG Duty label - worded to customer requirements. Rivetted on. PB & BG Tag label - worded to customer requirements. Screwed on. SW1 1 2 3 4 5 6 SW1 SW2 1 2 3 4 5 6 Basic single changeover switch wiring diagram. Note: additional terminal as standard for ATEX/CENELEC units. Basic double changeover switch wiring diagram. Note: additional terminal as standard for ATEX/CENELEC units. For versions containing inline and end of line resistors or diodes, please specify your requirements. ALL DIMENSIONS IN INCHES & MILLIMETERS ALL DIMENSIONS IN MILLIMETERS Ordering Requirements The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Standard products available ex-stock. Please visit www.coopermedc.com for further details. Model Certification BG PB Certification Code ATEX/CENELEC – Ex ed EB ATEX/CENELEC – Exi IB CSA – Exi (PBI only) IC UL – Listed UL UL - Ordinary locations UW GOST ‘R’ – Exi IG* GOST ‘R’ – Ex ed EG* GOST ‘K’ – Exi (PBI only) IK CQST – Ex ed EQ† CQST – Exi IQ† Inmetro – Ex ed EM Inmetro – Exi IM Uncertified WN * Russian Fire Approved as standard. † Not suitable for use in China on fire alarm systems Entries Labels Entries M16 M20 1/2" NPT Code *A *B *C Voltage Voltage a.c. d.c. Switches Code A D UL & CSA versions only available with 1/2" NPT entries. Code 0 1 2 3* 4* 5* Terminals Options Code None N LED A Lift Flap (BG only) B Resistor Series C* Resistor EOL D* Diode E† Earth Continuity F** Turn & Push (PB only) T† Self reset (PB only) M Resistor Series & EOL S*‡ Plastic element replaces Break glass P *Prefix entry size (see diagram above) with entry position code e.g. 1A, 2A, 4B, 6B. Labels None Glass label (1) reqd. Glass label (2) reqd. Glass label (3) reqd. Duty label reqd. Tag label reqd. Options Finish Finish Code Red (Standard) R Natural Black N Blue B Yellow Y Grey G Yellow/Black X Stripes Special S* * Please specify * Specify values † Not available for UL/CSA versions. ‡ Choose for BGE or PBE only – on BGI/W or PBI/W choose C & D ** Must be selected when selecting CSA certification * Specify wording on 3, 4 or 5 as required. Switches Single changeover Double changeover Code S D Terminals Code 6 x 2.5mm2 (standard) 6* 7 x 2.5mm2 (standard) 7 9 x 2.5mm2 (optional) 9 * BGUL only availablewith six terminals All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. 02/12 MANUAL CALL POINTS Exed, Intrinsically Safe (Exia), Weatherproof BG Range & PB Range Features ᔢ Polyester enclosure – light, strong and not subject to corrosion. ᔢ 2 models: Breakglass. Pushbutton. ᔢ 4 basic versions available: (1) Explosion protected Exe (ATEX, Chinese [CQST],Brazilian [Inmetro]) (2) Explosion protected Exi (ATEX, GOST ‘R’, GOST ‘K’, Chinese (CQST), Brazilian [Inmetro] or CSA), (3) Explosion protected: Class I, Div. 2, Groups A-D Class II, Div. 2, Groups F & G (PB only) Class I, Zone 2 (4) Weatherproof & Dust-tight/UL ordinary locations. ᔢ In line and end of line resistors and/or zener diodes can be fitted. ᔢ Variety of colours available. ᔢ Up to 9 terminals available. ᔢ Lift flap available for extra protection against inadvertent operation. Introduction These manual fire alarm call points have been designed for use in hazardous locations and harsh environmental conditions. The GRP enclosures are suitable for use offshore or onshore, where lightweight combined with a high level of corrosion resistance is required. ᔢ Optional LED – this indicates that the unit has been operated – useful for testing purposes. ᔢ Earth continuity option for metal glands. ᔢ 1 or 2 changeover switches. ᔢ Captive cover screws. ᔢ SIL 2 Certified. Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK. Sales Enq. UK: +44 (0)1773 864 100 Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA Sales Enq. USA: +1 (713) 937- 9772 E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com 6DS067/S Features Breakglass Model ᔢ No hammer required – the glass is covered by a membrane thus protecting the operator from glass fragments. ᔢ A plastic ‘Break glass’ or deformable operating element is available to replace the break glass*. Once the flexible element is pressed it bends but will not break. The unit is reset by repositioning the element. All other functions remain the same. ᔢ Complies with the British Standard for call points. ᔢ Key operated test facility – simple but secure. ᔢ Breakglass hammer available. Pushbutton Model ᔢ Stayput as standard or self reset available. ᔢ Lift Flap as standard. (Not turn and push model). *Note: Deformable operating element does not comply with BS5839 Part 2. Specification Model: BGW & PBW Protection: Weatherproof/ dust proof Certification: Weatherproof/ dust proof BGE & PBE BGI & PBI Explosion Protected Class I, Div 2 Class II, Div 2 Explosion Protected Exed (Increased Safety) Explosion Protected Exia (Intrinsically Safe) UL Listed to Class I, Div 2, Groups A-D BGUL & PBUL Class II, Div 2, Groups F & G (PBUL only) Listing No. E186629 ATEX approved Ex II 2GD BAS02ATEX2105X (PB only) ATEX approved Ex II 1GD Baseefa 03ATEX0084X (PB only) ATEX approved Ex II 1G Baseefa 03ATEX0084X (BG only) *BGUL & PBUL IP66/IP67 ATEX approved Ex II 2G BAS02ATEX2105X (BG only) Exia IIC T4 CENELEC EN50014 CENELEC EN50020 Suitable for use in Zones 0, 1 & 2 Exed IICT6 (switch only) Exedm IICT4 (other versions) CENELEC EN50014 EN50019 EN50018 EN50028 Suitable for use in Zones 1 & 2 UL listed for ordinary locations Listing No. S8117 *Refer to UL data sheet at rear of catalogue for complete information Chinese Certification (PBE & BGE):† CQST – Exed IIC T6 (switch only) Exedm IIC T4 (other versions) GOST ‘R’ Certification (PBE & BGE): Exedm IIC T6 Exedm IIC T4 (other versions) Russian Fire Approved Brazilian (Inmetro) Certification: BR-Ex emd IIC T4 or BR-Ex ed IIC T6 CSA Certification to C22.2 (PBI only): Nos.0-M, 0.4-M, 14-M, 25, 30-M, 94, 142-M1987, 157-M1987, 157-92, Enclosure Type 4. T4A Class I Groups A, B, C & D Cert. No. 79120 GOST ‘R’ Certification (PBI & BGI): Exia IIC T4 Russian Fire Approved GOST ‘K’ Certification (PBI only): Exia IIC T4 SIL 2 Certification to 61508. Cert. No. Sira 11013 (BGE only). Chinese Certification (PBI & BGI): CQST – Exia IIC T4 American Bureau of Shipping Type Approval BGE only Brazilian (Inmetro) Certification: BR-Ex ia IIC T4 American Bureau of Shipping Type Approval Voltage: Certified Temp: Up to 254V Up to 240V –40°C to +55°C Weatherproof –25°C to +55°C (PBUL) –25°C to +55°C (BGUL) Switch Ratings: (1 or 2 changeover switches fitted) Up to 250V Up to 28V (IS) –20°C to +50°C ATEX/CENELEC –40°C to +70°C (PBI) ATEX/CENELEC –40°C to +50°C (BGI) UL Version CSA –50°C to +40°C (PBI only) d.c. - 0-30v 5A (resistive) or 3A (inductive) 30-50 1A resistive or inductive a.c. - 0-254V 5A resistive or inductive NOT APPLICABLE Note: UL versions Max Rating 240VAC, 3A Material: Anti static U.V. resistant glass reinforced polyester. Finish: Red painted finish as standard or to Customer specification. British Standard for Call Points: BS 5839 : Part 2 : 1983 (BG). Weight: 1.2 kg. (Varies with model & entries). Ingress Protection: IP66 & IP67. Entries: Up to 4 entries, M16 or M20 top and bottom (1/2" NPT available on UL version). Terminals: 6 x 2.5mm2 – standard (BGUL only). 7 x 2.5mm2 – standard. 9 x 2.5mm2 optional – up to 60V only. Risistors & Diodest: Various configurations available on versions up to 24V and all "IS" versions. (Minimum Resistor value 100ΩPBE/BGE, 470ΩPBI/BGI). Earth Continuity: Internal & external earth continuity is provided via an optional earth plate. LED Indication: A high intensity red LED can be fitted as an optional extra to indicate operation on versions up to 24V and all "IS" versions. Labels: BG Glass label - reads either (1) Fire Break glass – press here (2) Break glass – press here (3) Worded to customer requirements. PB & BG Duty label - worded to customer requirements. Rivetted on. PB & BG Tag label - worded to customer requirements. Screwed on. SW1 1 2 3 4 5 6 SW1 SW2 1 2 3 4 5 6 Basic single changeover switch wiring diagram. Note: additional terminal as standard for ATEX/CENELEC units. Basic double changeover switch wiring diagram. Note: additional terminal as standard for ATEX/CENELEC units. For versions containing inline and end of line resistors or diodes, please specify your requirements. ALL DIMENSIONS IN INCHES & MILLIMETERS ALL DIMENSIONS IN MILLIMETERS Ordering Requirements The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Standard products available ex-stock. Please visit www.coopermedc.com for further details. Model Certification BG PB Certification Code ATEX/CENELEC – Ex ed EB ATEX/CENELEC – Exi IB CSA – Exi (PBI only) IC UL – Listed UL UL - Ordinary locations UW GOST ‘R’ – Exi IG* GOST ‘R’ – Ex ed EG* GOST ‘K’ – Exi (PBI only) IK CQST – Ex ed EQ† CQST – Exi IQ† Inmetro – Ex ed EM Inmetro – Exi IM Uncertified WN * Russian Fire Approved as standard. † Not suitable for use in China on fire alarm systems Entries Labels Entries M16 M20 1/2" NPT Code *A *B *C Voltage Voltage a.c. d.c. Switches Code A D UL & CSA versions only available with 1/2" NPT entries. Code 0 1 2 3* 4* 5* Terminals Options Code None N LED A Lift Flap (BG only) B Resistor Series C* Resistor EOL D* Diode E† Earth Continuity F** Turn & Push (PB only) T† Self reset (PB only) M Resistor Series & EOL S*‡ Plastic element replaces Break glass P *Prefix entry size (see diagram above) with entry position code e.g. 1A, 2A, 4B, 6B. Labels None Glass label (1) reqd. Glass label (2) reqd. Glass label (3) reqd. Duty label reqd. Tag label reqd. Options Finish Finish Code Red (Standard) R Natural Black N Blue B Yellow Y Grey G Yellow/Black X Stripes Special S* * Please specify * Specify values † Not available for UL/CSA versions. ‡ Choose for BGE or PBE only – on BGI/W or PBI/W choose C & D ** Must be selected when selecting CSA certification * Specify wording on 3, 4 or 5 as required. Switches Single changeover Double changeover Code S D Terminals Code 6 x 2.5mm2 (standard) 6* 7 x 2.5mm2 (standard) 7 9 x 2.5mm2 (optional) 9 * BGUL only availablewith six terminals All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. 02/12 PH1 Range - PULL HANDLE CALL POINT Exd, Weatherproof Features ᔢ Zone 1 and Zone 2 use. ᔢ Ex d IIC T6 Gb ᔢ Ex tb IIIC T85ºC Db ᔢ IECEx certified Gb, Db ᔢ ATEX certified Ex II 2 GD ᔢ IP66 & 67 ᔢ Certified temperature: -55ºC to +70ºC ᔢ Corrosion free GRP construction ᔢ Optional in line, end of line resistors and diodes ᔢ Retained stainless steel cover screws Introduction The PH1 double action pull handle call point has been designed for use in flammable atmospheres and harsh environmental conditions. The GRP enclosure is suitable for use offshore or onshore where light weight combined with a high level of corrosion resistance is required. Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK. Sales Enq. UK: +44 (0)1773 864 100 Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA Sales Enq. USA: +1 (713) 937- 9772 E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com 6DS130/A Specification Certification: Certified to IEC60079-0, IEC60079-1 and IEC60079-31 Certified to EN60079-0, EN60079-1 and EN60079-31 IECEx Cert. No. IECEx ITS 11.0021X Atex Cert. No. ITS11ATEX17308X Ex II 2 GD Ex d IIC T6 Gb, Ex tb IIIC T85ºC Db Material: Body/covers/handles:- GRP (glass reinforced polyester) Fixings:- Stainless steel grade 316 Finish: Cover:- natural red, Body:- natural black. Handles:- natural white. Cover may be painted to customer's requirements. Voltage: 0-50Vdc, 0-254Vac. Switch Rating: 1 or 2 c/o switches, 254V, 3A max. Weight: Gross weight 3.2Kg. Net weight 2.6Kg Certified Temp: -55°C to +70°C. Ingress Protection: IP66 & 67. Entries: Up to 2 x M20 or M25, up to 2 x 1/2” or 3/4” NPT. Terminals: 6 x 2.5mm2 as standard. Contact Cooper MEDC for options. Earth Continuity: Earth continuity is provided by internal plate. Labels: 'Burning house' label fitted as standard on red units. Blank label fitted as standard on all other colour units. Tag & Duty label options, worded to customers requirements. Addr. module: Consult Cooper MEDC for options. Resistors: Various configurations available, 470 Ohms minimum. Diodes: Various configurations available. SINGLE SWITCH DOUBLE SWITCH SINGLE SWITCH DOUBLE SWITCH SINGLE SWITCH DOUBLE SWITCH Standard wiring switch only Standard wiring c/w EOL resistor R1 - EOL Resitor Standard wiring c/w series resistor or series & EOL resistor R1 - Series Resitor R2 - EOL Resitor (if fitted) ALL DIMENSIONS IN MILLIMETRES Ordering Requirements The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Model Entries Certification Switches Features Finish PH1 Certification ATEX IECEx Code B J Entries M20 M25 1/2" NPT 3/4" NPT Code *B *C *M *N Switches Single changeover Double changeover * Prefix entry size with entry position (see diagram above). E.g. 4B6B. Maximum 2 Entries Code S D Features None Series resistor EOL resistor Diode Tag label Duty label Code N G* H* E* T* D* Finish Natural Red Special Code R S* * Please specify * Please specify NOTE: the units can be internally wired to suit customers specifications. Please discuss your requirements with us. All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. 02/12 SM87 BG & PB Range - MANUAL CALL POINTS Intrinsically Safe (Exia), Exd, Weatherproof Features ᔢ Zone 0, Zone 1 and Zone 2 use*. ᔢ Exia IIC T4 or Exd IIC T5/T6. ᔢ ATEX aproved, Ex II 1G (Exia) Ex II 2GD (Exd). ᔢ BASEEFA certified ᔢ UL Listed (PB only), Class I, Div 1, Groups C & D. ᔢ CSA certified. ᔢ IECEx certified Gb, Db. ᔢ GOST ‘R’ & ‘K’* certified. ᔢ Chinese (CQST) certified. ᔢ Brazilian (Inmetro) certified. ᔢ IP66 and IP67. ᔢ Certified temperature: –55°C to +70°C*. ᔢ Stainless steel or marine grade alloy. ᔢ Robust yet lightweight. ᔢ Easy to maintain. *Depending on version. Introduction These manual fire alarm, emergency shutdown breakglass and pushbutton units have been designed for the most arduous environmental conditions. The units are both easy to install and maintain. Intrinsically safe Exia and flameproof Exd versions of each model are available. A choice of either stainless steel or alloy makes the range suitable for either the offshore or onshore industries. Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK. Sales Enq. UK: +44 (0)1773 864 100 Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA Sales Enq. USA: +1 (713) 937- 9772 E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com 6DS015/O Specification Type: Breakglass unit, latching Lift flap, Breakglass, latching Push button, latching, key reset Push button, self reset Certification: Ex d certified to IEC60079-0, IEC60079-1, IEC60079-31 Ex d certified to EN60079-0, EN60079-1, EN60079-31 Exia certified to IEC60079-0, IEC60079-11, IEC60079-26 Exia certified to EN60079-0, EN60079-11, EN60079-26 Ex d ATEX Cert. No. Baseefa03ATEX0075 Ex II 2 GD Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db Exia ATEX Cert. No. Baseefa02ATEX0152X Ex II 1 G Ex ia IIC T4 Ga Ex d IECEx Cert. No. IECEx BAS 09.0060 Ex d IIC T5/6 Gb, Ex tb T85°C/T100°C Db Exia IECEx Cert. No. IECEx BAS 10.0033X Exia IIC T4 Ga UL Listed: Class I, Div1 Groups C & D (PBL only). Listing No: 186629. CSA Certification: Class I Groups A-D I.S. version (SM87 PBI only). Class I, Div 1 & 2, Group D (Exd – SM87 PB & SM87 BG). GOST ‘R’ Certification: 1Exib IIC T4, 1Exd IIC T4 Russian Fire Approval GOST ‘K’ Certification: Exib IIC T4. Chinese Certification: CQST – Exia IIC T4, Exd IIC T5/T6. † Brazilian (Inmetro) Certification: BR-Ex d IIC T5/T6, BR-Ex ia IIC T4 Material: Grade 316 ANC4B Stainless Steel or LM 25 TF Marine Grade Alloy. Finish: Paint finish as standard or to customer specification. Voltage: Exd 24V a.c./d.c. Exia 28V. Rating: 2 amp. Switches 2 pole c/o, wired to terminals. Optional up to 4 pole (UL version 2 pole only). Type SM87BGL Type SM87LBGL Type SM87PBL Type SM87PBM ALL DIMENSIONS IN MILLIMETERS Both the Exia units and the Exd units have the same external appearance. Also the internal components are identical throughout the range. Each unit can be wired for either NO, NC or CO contacts to customer specification. Optional Indicator: A red high intensity LED can be fitted for alarm indication. Certified Temp: Weight: Exd*–55°C to +70°C. Exi*–55°C to +55°C. –20°C to +55°C (LED version only). UL –55°C to +70°C, –20°C to +55°C (LED version only). CSA –50°C to +55°C (Exd), –50°C to +40°C (Exi). *Note: includes ATEX, IECEx, GOST, Brazilian & Chinese versions. 3·8 kg. steel (approx.) or 2.5 kg. alloy (approx.). Ingress Protection: IP66 and IP67. SM87 PB IP68 (40m for 8 hours). Entries: Up to 4 x M20 or M25 ISO Exd/Exia. Up to 4 x 1/2" or 3/4" NPT UL Terminals: Will accept up to 2·5mm2 cable. Resistor Values: 470R minimum (d.c. & I.S. units only). Ordering Requirements The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Unit Model Material Certification Entries Duty Label Tag Label Options Finish Options Code Not required N LED A Resistor Series G* Resistor EOL H* Diode D* 3 Pole T c/o Switch 4 Pole F c/o Switch Other O* Finish Code Red R Blue B Yellow Y Yellow/ X Black Stripes Special S* SM87 *Model Code Breakglass Latching BGL Lift Flap Breakglass Latching LBGL Push Button Latching key reset PBL Push Button Only PBM Momentary Action * UL version only available in PBL model. *Material Code Stainless Steel S Alloy A * UL version only available in Alloy. Certification Exia Exd IECEx Exi IECEx Exd UL CSA – Exi CSA – Exd GOST ‘K’ – Exi GOST ‘R’ Exi GOST ‘R’ Exd Chinese Exi Chinese Exd Inmetro Exi Inmetro Exd Code I D IJ DJ UL IC DC IK IG* DG* IQ† DQ† IM DM * Russian Fire Approval as standard. † Not suitable for use in China on fire alarm systems Entries M20 M25 1/2" NPT 3/4" NPT Other Code 1 2 3 4 5 Position Top Bottom RHS LHS *T *B *R *L * Prefix position with size code i.e. 1T 1B = 20mm Top and Bottom. Duty Label Code Fire-Breakglass 1 Push Button 2 Fire-Push Button 3 ESDO-Abandon 4 Other O* None N * Please specify * Please specify * Please specify Label Code Required Y* Not Required N * Please specify All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. 02/12 SM87 BG & PB Range - MANUAL CALL POINTS Intrinsically Safe (Exia), Exd, Weatherproof Features ᔢ Zone 0, Zone 1 and Zone 2 use*. ᔢ Exia IIC T4 or Exd IIC T5/T6. ᔢ ATEX aproved, Ex II 1G (Exia) Ex II 2GD (Exd). ᔢ BASEEFA certified ᔢ UL Listed (PB only), Class I, Div 1, Groups C & D. ᔢ CSA certified. ᔢ IECEx certified Gb, Db. ᔢ GOST ‘R’ & ‘K’* certified. ᔢ Chinese (CQST) certified. ᔢ Brazilian (Inmetro) certified. ᔢ IP66 and IP67. ᔢ Certified temperature: –55°C to +70°C*. ᔢ Stainless steel or marine grade alloy. ᔢ Robust yet lightweight. ᔢ Easy to maintain. *Depending on version. Introduction These manual fire alarm, emergency shutdown breakglass and pushbutton units have been designed for the most arduous environmental conditions. The units are both easy to install and maintain. Intrinsically safe Exia and flameproof Exd versions of each model are available. A choice of either stainless steel or alloy makes the range suitable for either the offshore or onshore industries. Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK. Sales Enq. UK: +44 (0)1773 864 100 Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA Sales Enq. USA: +1 (713) 937- 9772 E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com 6DS015/O Specification Type: Breakglass unit, latching Lift flap, Breakglass, latching Push button, latching, key reset Push button, self reset Certification: Ex d certified to IEC60079-0, IEC60079-1, IEC60079-31 Ex d certified to EN60079-0, EN60079-1, EN60079-31 Exia certified to IEC60079-0, IEC60079-11, IEC60079-26 Exia certified to EN60079-0, EN60079-11, EN60079-26 Ex d ATEX Cert. No. Baseefa03ATEX0075 Ex II 2 GD Ex d IIC T5/T6 Gb, Ex tb IIIC T85°C/T100°C Db Exia ATEX Cert. No. Baseefa02ATEX0152X Ex II 1 G Ex ia IIC T4 Ga Ex d IECEx Cert. No. IECEx BAS 09.0060 Ex d IIC T5/6 Gb, Ex tb T85°C/T100°C Db Exia IECEx Cert. No. IECEx BAS 10.0033X Exia IIC T4 Ga UL Listed: Class I, Div1 Groups C & D (PBL only). Listing No: 186629. CSA Certification: Class I Groups A-D I.S. version (SM87 PBI only). Class I, Div 1 & 2, Group D (Exd – SM87 PB & SM87 BG). GOST ‘R’ Certification: 1Exib IIC T4, 1Exd IIC T4 Russian Fire Approval GOST ‘K’ Certification: Exib IIC T4. Chinese Certification: CQST – Exia IIC T4, Exd IIC T5/T6. † Brazilian (Inmetro) Certification: BR-Ex d IIC T5/T6, BR-Ex ia IIC T4 Material: Grade 316 ANC4B Stainless Steel or LM 25 TF Marine Grade Alloy. Finish: Paint finish as standard or to customer specification. Voltage: Exd 24V a.c./d.c. Exia 28V. Rating: 2 amp. Switches 2 pole c/o, wired to terminals. Optional up to 4 pole (UL version 2 pole only). Type SM87BGL Type SM87LBGL Type SM87PBL Type SM87PBM ALL DIMENSIONS IN MILLIMETERS Both the Exia units and the Exd units have the same external appearance. Also the internal components are identical throughout the range. Each unit can be wired for either NO, NC or CO contacts to customer specification. Optional Indicator: A red high intensity LED can be fitted for alarm indication. Certified Temp: Weight: Exd*–55°C to +70°C. Exi*–55°C to +55°C. –20°C to +55°C (LED version only). UL –55°C to +70°C, –20°C to +55°C (LED version only). CSA –50°C to +55°C (Exd), –50°C to +40°C (Exi). *Note: includes ATEX, IECEx, GOST, Brazilian & Chinese versions. 3·8 kg. steel (approx.) or 2.5 kg. alloy (approx.). Ingress Protection: IP66 and IP67. SM87 PB IP68 (40m for 8 hours). Entries: Up to 4 x M20 or M25 ISO Exd/Exia. Up to 4 x 1/2" or 3/4" NPT UL Terminals: Will accept up to 2·5mm2 cable. Resistor Values: 470R minimum (d.c. & I.S. units only). Ordering Requirements The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Unit Model Material Certification Entries Duty Label Tag Label Options Finish Options Code Not required N LED A Resistor Series G* Resistor EOL H* Diode D* 3 Pole T c/o Switch 4 Pole F c/o Switch Other O* Finish Code Red R Blue B Yellow Y Yellow/ X Black Stripes Special S* SM87 *Model Code Breakglass Latching BGL Lift Flap Breakglass Latching LBGL Push Button Latching key reset PBL Push Button Only PBM Momentary Action * UL version only available in PBL model. *Material Code Stainless Steel S Alloy A * UL version only available in Alloy. Certification Exia Exd IECEx Exi IECEx Exd UL CSA – Exi CSA – Exd GOST ‘K’ – Exi GOST ‘R’ Exi GOST ‘R’ Exd Chinese Exi Chinese Exd Inmetro Exi Inmetro Exd Code I D IJ DJ UL IC DC IK IG* DG* IQ† DQ† IM DM * Russian Fire Approval as standard. † Not suitable for use in China on fire alarm systems Entries M20 M25 1/2" NPT 3/4" NPT Other Code 1 2 3 4 5 Position Top Bottom RHS LHS *T *B *R *L * Prefix position with size code i.e. 1T 1B = 20mm Top and Bottom. Duty Label Code Fire-Breakglass 1 Push Button 2 Fire-Push Button 3 ESDO-Abandon 4 Other O* None N * Please specify * Please specify * Please specify Label Code Required Y* Not Required N * Please specify All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. 02/12