HE Series Selectable Candela Evacuation Signals

advertisement
HE Series Selectable Candela Evacuation Signals
STANDARD FEATURES
HEC/HES/HEH
APPLICATIONS
The HE Series is a low profile strobe and horn/strobe
combination that offers dependable audible and visual
alarms and the lowest current available.
The HE Series 24VDC offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110
candela.
The 12VDC models offers tamperproof field selectable
candela options of 15, 30, 60, and 75 candela. The
HE Series horn offers a continuous or synchable
temporal three in 2400Hz and mechanical tone, a
chime and whoop tone. All tones are easy for the
professional to change in the field by using switches.
The HE Series has a minimal operation current and
has a minimum flash rate of 1Hz regardless of input
voltage.
The HE Series is shipped with the standard 4" metal
mounting plate which incorporates the popular Slide
feature that allows the installer to easily test for
supervision. The product also features a locking
mechanism which secures the product to the bracket
without any screws showing.
• Nominal voltage 12VDC and 24VDC
• 24VDC units have field selectable candela options
of 15, 30, 60, 75, and 110 candela
• 12VDC units have field selectable candela options of
15, 30, 60, and 75 candela
• Unit Dimensions: 5" high x 4.5" wide x 2.5" deep
• Synchronize strobe and/or horn with Hochiki Series
Control Module (12VDC product must use the
HAVSM Module)
• Prewire entire system, then install signals
• Lower installation and operating costs
• Input terminals supports 12 to 18 gauge wire
• Switch selection for high or low dBA
• Switch for chime, whoop, mechanical and 2400Hz
tone
• Switch for continuous or temporal 3 (not available on
whoop tone)
• Surface mount with the HSB (Hochiki surface
mount box)
• Silence horn while strobes remain flashing
• Wide voltage range 8-17.5VDC (12VDC units) 1633VDC or FWR (24VDC units)
• Faceplate available in red or off-white
PRODUCT LISTINGS
California State
Fire Marshal
• UL 464 & UL 1971 Listed - S8369
• CSFM Listed - 7135-0410:0187, 7135-0410:0188
Product Compliance
• NFPA 72
• Americans with Disabilities Act (ADA)
The HE Series appliances are UL 464 and UL 1971
listed for use with fire protective systems and are
warranted for three years from date of purchase.
Specifications subject to change without notice.
Hochiki America Corporation
7051 Village Drive, Suite 100 Buena Park, CA 90621-2268
Phone: 714/522-2246 Fax: 714/522-2268
Technical Support: 800/845-6692 or technicalsupport@hochiki.com
Continued on back.
Find latest revision at www.hochiki.com
F0103
11/2013
HEH 12VDC or 24VDC Low Profile Evacuation Horn
Model Number
Part Number
HEH24-WR
HEH24-WW
0500-05880
0500-05890
Nominal
Voltage
24VDC
24VDC
Reverberant dBA
@ 10ft., per UL 464
62-82
62-82
In Anechoic Room
dBA @10ft.
100
100
HES3 12VDC or 24VDC Selectable Candela Low Profile Evacuation Strobe
Model
Number
HES3-12WR
HES3-12WW
HES3-12PWR 12
HES3-12PWW
HES3-24WR
HES3-24WW
HES3-24PWR
HES3-24PWW
Part
Number
0500-05900
0500-05910
0500-05920
0500-05930
0500-05940
0500-05950
0500-05960
0500-05970
Nominal
Voltage
12 VDC
12 VDC
12 VDC
12 VDC
24 VDC
24 VDC
24 VDC
24 VDC
Candela
(UL 1971)
15, 30, 60, 75
15, 30, 60, 75
15, 30, 60, 75
15, 30, 60, 75
15, 30, 60, 75, 110
15, 30, 60, 75, 110
15, 30, 60, 75, 110
15, 30, 60, 75, 110
Model Designations:
W = Wall mount R = Red faceplateW = Off-white
faceplateP = Plain (no lettering)
ALERT bezel available
AGENT bezel available.
HEC3 12VDC or 24VDC Selectable Candela Low Profile Evacuation Horn/Strobe
Model
Number
HEC3-12WR
HEC3-12WW
HEC3-12PWR
HEC3-12PWW
HEC3-24WR
HEC3-24WW
HEC3-24PWR
HEC3-24PWW
Part
Number
0500-05980
0500-05990
0500-06000
0500-06010
0500-06020
0500-06030
0500-06040
0500-06050
Nominal
Voltage
12 VDC
12 VDC
12 VDC
12 VDC
24 VDC
24 VDC
24 VDC
24 VDC
Candela
(UL 1971)
15, 30, 60, 75
15, 30, 60, 75
15, 30, 60, 75
15, 30, 60, 75
15, 30, 60, 75,
15, 30, 60, 75,
15, 30, 60, 75,
15, 30, 60, 75,
HE3-12 Product Strobe Current Ratings
Candela
12VDC
UL Max
15cd
106mA
92mA
30cd
131mA
141mA
60cd
186mA
260mA
75cd
237mA
312mA
110
110
110
110
Reverberant dba @
10ft., per UL 464
62-82
62-82
62-82
62-82
62-82
62-82
62-82
62-82
In Anechoic Room
dBA @ 10ft.
100
100
100
100
100
100
100
100
HE3-24 Product Strobe Current Ratings
Candela
24VDC
UL Max
15cd 30cd
30mA 35mA
42mA 58mA
60cd
66mA
97mA
75cd
110cd
80mA 103mA
116mA 161mA
HE3-12 Product Horn Current Ratings
NOTES:
• Operating temperature: 32°to 120°F (0°
to 49° C). The HE Series is not listed for
outdoor use.
• The sound output for the temporal 3
tone is rated lower since the time the horn
is off is averaged into the sound output
rating. While the horn is producing a tone
in the temporal 3 mode its sound pressure
is the same as the continuous mode.
• For nominal and peak current across UL
regulated voltage range for filtered DC
HE3-24 Product Horn Current Ratings
power and unfiltered (FWR [Full Wave
Horn Mode
Minimum dBA
Minimum dBA
Regulated 24VDC Rectified]) power, see installation manual.
@ 10ft., per
@ 10ft., per
Max. Operating @ 12VDC models are DC only.
UL 464 (HIGH)
UL 464 (LOW) High Setting (mA)
• Hochiki does not recommend using a
Temp 3 2400Hz
78
71*
28
coded or pulsing signaling circuit with any
Temp 3 Mechanical
76
70*
25
of our strobe products (see Technical
Temp 3 Chime
70*
66*
15
Bulletin 014).
Continuous 2400Hz
81
74*
28
Continuous Mechanical
80
72*
25
Continuous Chime
70*
66*
15
Whoop
82
69*
56
Horn Mode
Minimum dBA
@ 10ft., per
UL 464 (HIGH)
Temp 3 2400Hz
76
Temp 3 Mechanical
75
Temp 3 Chime
62*
Continuous 2400Hz
79
Continuous Mechanical
78
Continuous Chime
63*
Whoop
78
Minimum dBA
@ 10ft., per
UL 464 (LOW)
69*
68*
60*
74*
72*
61*
71*
Regulated 12VDC
Max. Operating @
High Setting (mA)
29
26
13
29
26
13
55
*Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level
required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use.
Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always
private mode).
1
RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the
listed voltage range (16-33VDC for 24VDC units) (8-17VDC for 12VDC units). For strobes the UL max current is
usually at the minimum listed voltage (16VDC for 24VDC units) (8VDC for 12VDC units). For audibles the max current is
usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual.
Hochiki America Corporation HE Series Selectable Candela Evacuation Sginals
Specifications subject to change without notice.
Download