Post Top Luminaire CFT500 1 © WE-EF 2015 Post Top Luminaire CFT500 Mechanical Features Design : Decorative Two Light Distributions [C50] and [R] Lens/Cover with OLC® und RFC® Technology Eco Step Dim® (on request) Surge Protection (6/6kV), Optional SP10 (10/10kV) 2 © WE-EF 2015 Post Top Luminaire CFT500 Luminaire is factory sealed and does not need to be opened during installation IP66 Classification Electrical Protection Class I Impact Protection IK 08 CCG® (Controlled Compression Gasket) Technology OLC® (One LED Concept) Technology RFC® (Reflection Free Contour) Technology 5CE Superior Corrosion Protection PCS (Polymer Coated stainless Steel) Hardware 3 © WE-EF 2015 Post Top Luminaire CFT500 The OLC® technology is the ideal method for achieving a uniform and energy saving lighting solution, providing highest safety and visual comfort, in ensuring that the failure of invidual LEDs does not lead to an adverse affect in the lighting RFC® Technology – engineered with a clear PMMA UV stablised panel which has a contoured surface, contoured in a way that imitates the shape of the LED lens; the goal is to minimise the loss of light that normally occurs due to internal reflection 4 © WE-EF 2015 Post Top Luminaire CFT500 With the intelligent use of a built-in vent, pressure fluctuations are equalized reliably and less strain is put on the seals, ensuring the sensitive interior electronics are protected against moisture penetration for years to come. Using either a1-10V or DALI interface with electronic converter, the light output and energy usage of the invidual luminaires can be controlled. All components of the luminaire are engineered for reliability and longevity. 5 © WE-EF 2015 Post Top Luminaire CFT500 PCS coated fasteners made from austinetic stainless steel reduce the risk of galvanic corrosion Outstanding and long lasting anticorrosion properties can only be achieved by a comprehensive, integrated approach. WE-EF‘s unique 5CE system encompasses 5 Critical Elements: Material, Conversion Coating, Powder Coating, PCS Hardware and Process Control 6 © WE-EF 2015 Post Top Luminaire CFT500 Features Electrical LED Boards Built in ‚polarity‘ protection Bypass device. If one LED fails, it is removed from the circuit guaranteeing the remaining LEDs continue to function 7 © WE-EF 2015 Post Top Luminaire CFT500 Features Electrical LED Board Lifetime > 60.000 Hrs. Measured and Calculated according to: LM80-08 TM21 Diagram (Based on XPXP-G and WEWE-EF Luminaires, measured to over 10.000 hours.) 8 © WE-EF 2015 Post Top Luminaire CFT500 Features Electrical Lifetime: LED Driver Integral thermal switch (NTC) protects against over temperature operation e.g. excessive ambient temperature Defined as the predicted point when 10% failures will occur. This life rating is specific to the CFT400 luminaire and is based on the Driver operating in the luminaire and in the stated temperatures. > 40.000 Stunden (Ta 40°C ) > 50.000 Stunden (Ta 25 C) 9 © WE-EF 2015 Post Top Luminaire CFT500 Features Electrical Optional: surge Protection (SP10) The CFT540 is fitted with 6/6 kV , which is integrated in the LED driver, in accordance with IEC 61643-11. If the surge protector has been triggered by an adverse event, the luminaire is automatically disconnected from the mains. In risk areas we recommend the addition of a 10/10kV optional WE-EF surge protection SP10 for the luminaire. Important: For comprehensive protection of the lumainire against lightning and electrical surges, we generally recommend primary (Type 1) and secondary (Type 2) surge arrestors be installed into the switch board 10 © WE-EF 2015 Post Top Luminaire CFT500 Features Electrical Optional: Eco Step Dim®® Four different options for controlling and managing the lighting (on request) Basic Motion Advanced Dynamic 11 © WE-EF 2015 Post Top Luminaire CFT500 Application The unique ‚butterfly‘ lens lies at the heart of OLC® Technology Two different lenses [C50] Symmetric distribution for lighting public spaces and car parks [C50] and [R] [R] Rectangular distribution for lighting public spaces and car parks 12 © WE-EF 2015 Post Top Luminaire CFT500 Application CFT540 36 LED 36 W / 350 mA / 4536 lm* 36 LED 72 W / 700 mA / 8294 lm* 4000 K (Optional 3000 K) [C50] [C50] [R] * Nominal lumen output based on LED manufacturers data at 85 C Tj. For rated lumens at 25 C Tq and latest data refer to www.we-ef.com [R] 13 © WE-EF 2015 Post Top Luminaire CFT500 Features High pressure die cast aluminium construction with integrated heat sink Marin grade ALSi12/LM6/CP401 aluminium alloy PCS (polymer coated system) stainless steel fasteners NB. External security fasteners PMMA Cover CCG® controlled compression gasket Benefits HPDC; precision, strength, repeatability, low tolerance. Optimal thermal management for LED’s Excellent corrosion protection 15% Teflon for friction reduced action and reduced risk of binding. Reduced friction between male and female thread causes tighter fit between connected parts. Prevents galvanic corrosion that otherwise occurs, when metals of dissimilar electronegatives are in contact UV-stablised and vandal resistant High ambient temperature rating 25 C Silicone gasket operates with controlled compression for longer life and maintained through life IP rating. Dust tight and high pressure water jet tight; long life, suitable for commercial and industrial applications, improved seal quality means less internal pollution and higher maintenance factors High reliability, extended component life Optical grade PMMA Lenses High Optical Efficiency of over 98%. Greater spacing. Option [C50] and [R] Lenses Choice and flexibility in the design process Exchangable LED Boards Future proof. New boards with less LEDs and less energy but higher light output can be retrofitted On average 70% Lumen maintenance > 60.000 hrs. Lifetime not affected by on/off switching Controls temperature variations, to protect LEDs from overheating IP66 protection rating for complete luminaire High efficiency, High quality, High output LED’s. Built in thermal management system (NTC) eg. Thermocouple monitoring to a preprogrammed and safe level (optional) Option 3000 K, 4000 K (Standard) 36 W to 72 W LED Ability to match other light sources in the design process and balance efficiency and ambience Flexible planning (Design) 14 © WE-EF 2015