Accessible Rest Room Code Requirements Chapter 11 - Accessibility Connecticut State Building Code 1999 ICC/ANSI A117.1 - 1998 CHAPTER 6 - PLUMBING ELEMENTS AND FACILITIES Section 606: Lavatories and Sinks ICC/ANSI A117.1 - 1998 606.1 General: Accessible lavatories and sinks shall comply with Section 606. ICC/ANSI A117.1 - 1998 606.2 Clear floor or ground space: A clear floor or ground space complying with Section 305.3 positioned for forward approach, shall be provided. Knee and toe clearance complying with Section 306 shall be provided. Exceptions: 1.) A parallel approach shall be permitted to a kitchen sink in a space where a cook top or conventional range is not provided. 2.) The dip of the overflow shall not be considered in determining knee and toe clearances. ICC/ANSI A117.1 - 1998 606.3 Height and clearances: The front of lavatories and sinks shall be 34 inches maximum above the floor or ground, measured to the higher of the fixture or counter surface. 27 min 685 34 max 865 8 min 205 9 min 230 17 min 430 11 min 280 Fig. 606.3 Height of Lavatories and Sinks 9 min 230 Fig. 306.3 Knee Clearance Fig. 306.2 Toe Clearance Drawings are for illustrative purposes only. Do not scale or submit as plans for permit. pwBICodeAccess3 1 Accessible Rest Room Code Requirements Chapter 11 - Accessibility Connecticut State Building Code 1999 ICC/ANSI A117.1 - 1998 CHAPTER 6 - PLUMBING ELEMENTS AND FACILITIES Section 606: Lavatories and Sinks (continued) ICC/ANSI A117.1 - 1998 606.4 Faucets: Faucets shall comply with Section 309. Hand operated, self closing faucets shall remain open for 10 seconds minimum. CT Supplement 1999 404.5 Faucets and controls: The controls to operate a faucet shall be located no more than 25 inches from the front face of a lavatory, kitchen sink, counter or vanity. At least one lavatory per gender per bathroom shall have its faucet and control located within 13 inches from the face of the fixture or vanity front. Lavatory faucets on accessible fixtures shall comply with the requirements of ICC/ANSI A117.1, formerly entitled CABO/ANSI A117.1, referenced in Chapter 14. ICC/ANSI A117.1 - 1998 606.5 Bowl depth: Sinks shall be 6 1/2 inches deep maximum. Multiple compartment sinks shall have at least one compartment complying with this requirement. ICC/ANSI A117.1 - 1998 Exposed pipes and surfaces: Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact. There shall be no sharp or abrasive surfaces under lavatories and sinks. International Plumbing Code - 1997 405.3.1 Water closet, lavatories, and bidets: With regards to lavatories (which would apply to accessible lavatories), this section states in part: lavatories shall not be set closer than 15 inches from its center to any side wall, partition, vanity or other obstruction.... pwBICodeAccess3 2 Accessible Rest Room Code Requirements Chapter 11 - Accessibility Connecticut State Building Code 1999 Lavatory and Water Closet Clear Floor Space Diagram The diagram below does not pertain to toilet compartments. ALL USE GROUPS EXCEPT USE GROUP “R” Face of wall 16" min 18" max 56"clear floor space 60" clear floor space 15" min from side wall 30" clear floor space Face of wall See section 404.5, pg. 2 when required. 13" min 17" min 48" clear floor space Drawings are for illustrative purposes only. Do not scale or submit as plans for permit. pwBICodeAccess3 3