Underfloor Busbar Systems

advertisement
Underfloor Busbar Systems (63-80A)
LINE
CONTENTS
E L E K T R İ K
Introduction
2-3
Technical Characteristics
4
Order Code System & Conductor Configuration
5
Standard Straight Length
6
Feeder Boxes & Elbows
7
Tap Off Plugs
8
Tap Off Boxes
9
Joint Installation
10
Plug Installation
11
Feeder Box Installation
12
System Manual
13
Raised-Off Floor Fixing Bracket Installation Manual
14
Application Area & Advantages
15
Product Overview
16
DABLINE
General Characteristics
One Bolt Joint Assembly
Achieved with a single action
by driving the mechanical and
electrical joint silver coated
springed contacts towards
each other. Only one bolt is
needed to fix the joint.
FAST, EASY AND
SAFE ASSEMBLY
- Addressable Tap-off Plugs
- Spring Contacts
- Integral Fixing Brackets
- Plug-in outlets every 300mm or
600mm option
- 1200mm-2400mm-3000mm optional
straight lengths
- Max. Height of the busbar is 49mm
Silver Plated Contacts
- The contacts at the joining
points of the busbar and
the contacts of all tap-off
units are silver plated
- The silver plating minimises
the contact impedances,
thus preventing the over-heating
of the contacts in case of
possible over-loads
MAXIMUM SAFETY
- IP55 Protection Degree
- Single Bolt joints
- Electrical Joints are Silver Plated
- Fully insulated conductors
- Halogen Free plastics up to 960 °C Fire rating
Plugs
- Keyed Tap-off
T
- Different colours for different type busbars
Tin Plated Conductors
49
The formation of Copper Oxide is
prevented by tin plating the full length
of the electrolytic copper conductors.
With this process, contact resistances
are minimised. The contacts of the tap-off
plugs grip the busbar conductors
on two surfaces
Maximum height 49 mm
Can be used in 50mm floor voids
Coded Tap-off Plugs
Arrangement of DABLINE Busbar
Systems are designed with different
pins to prevent incorrect assembly
2
E L E K T R İ K
PERFORMANCE
- Tested according to IEC 61439-6
- Rated up to 80A
- Up to 32A plugs available
- Optional plugs with MCB
- Housing is painted galvanised sheet steel
- High corrosion resistance
- Optional 5+1 wire conductors
- Tin plated electrolytic copper conductors
- Plastic or Metal Housing Feeder Box
- 3 or 5m Galvanised steel tap-off conduit
Colour Coded
Each busbar type has
a different colour code
Support System
Each busbar length is
complete with integral
floor fixing brackets.
IP55 Plug-in Outlets
Plug-in outlets have IP55
protection covers with
EPDM type gaskets
3
DABLINE
Technical Specifications
E L E K T R İ K
Rated Current
In
A
Busbar Code
Main Standards
Rated Isolation Voltage
Rated Operational Voltage
Rated Frequency
Pollution Degree
Protection Degree
External Mechanical Impacts (IK Code)*
Protection for Safety
Rated Conditional Short Circuit Current
63
80
06
08
IEC 61439-6:2012 Ed.1 ; IEC 61439-1 Ed.2:2011, TS EN 61439-1: 2011
690
690
Ui
V
690
690
Ue
V
50
50
Hz
f
IP55
IK07
Basic Protection (HD 60364-4-41, Clause A1)
kA
Icc
16
16
MECHANICAL DATA
Number of Conductor
Conductor Cross-section
Housing Cross-section (Cu equivalent)
Cable Terminal Capacity
Cable Section of 32A Plug
Cable Section of 13A Plug with Fuse
Plug Conduit (Up to 4 conductor)
Plug Conduit (With 5 and 6 conductor)
Flexible Corner Element Cable
Flexible Corner Conduit
Busbar Weight - for 5 conductor
mm2
mm2
2
mm
mm2
mm2
mmØ
mmØ
2
mm
mmØ
kg/m
3 to 5
8
13
16
4
1.5
16
20
10
25
1,46
3 to 5
12,6
13
16
4
1.5
16
20
10
25
1,57
MATERIAL FACILITY
Painted Galvanised Steel
High Conductivity Copper
Housing
Busbar Conductor
Busbar Isolators
Busbar Connection / Plug / Feeder Connections
Socket Outlet Entry Shutters
Plug Body
Busbar Cable Connections
Plug Connections
Plug / Flexible Corner Conduit (Metal)
Plug Conduit (Plastic)
Plug (Cable)
PPx-FR (according to RoHS and REACH standards)
PPx-FR (according to RoHS and REACH standards)
PPx-FR (according to RoHS and REACH standards)
PPx-FR (according to RoHS and REACH standards)
Copper
Copper
Galvanised Steel
V0 rated (Halogen Free)
LSOH - BS 7211
Tri-rated to BS 6231
PPx-FR (according to RoHS and REACH standards)
Brass
Galvanised Steel
Flexible Corner Connection Cable
Feeder Module / Flexible Connection Box
Feeder Module Connection Terminal / Earthing Terminal
Busbar Fixing Element
MEAN PHASE CONDUCTOR CHARACTERISTICS AT RATED CURRENT In
Resistance at a conductor temperature of 20 °C
Resistance at an ambient air temperature of 35 °C
Reactance (Independent from Temperature)
Positive and negative sequence impedances at an ambient air temperature of 35 °C
Positive and negative sequence impedances at a conductor temperature of 20 °C
R20
mW/m
mW/m
mW/m
mW/m
mW/m
2,293
3,063
0,422
3,092
2,331
1,483
1,981
0,273
2,000
1,507
Z(0)b20phN
Z(0)b20phPE
Z(0)b20phCPE
Z(0)bphN
Z(0)bphPE
Z(0)bphCPE
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
10,125
8,951
10,619
13,481
11,804
14,092
6,702
8,676
6,630
8,883
11,466
8,793
Rb20phph
Rb20phN
Rb20phPE
Rb20phCPE
Rbphph
RbphN
RbphPE
RbphCPE
Xbphph
XbphN
XbphPE
XbphCPE
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
mW/m
4,846
4,830
4,865
4,987
6,475
6,454
6,501
6,664
0,477
0,500
1,098
0,729
3,151
3,181
4,158
3,206
4,210
4,251
5,556
4,285
0,380
0,531
1,128
0,517
R
X
Z
Z20
MEAN FAULT-LOOP CHARACTERISTICS
Zero-sequence Impedance
Zero-sequence impedance at a conductor temperature of 20 °C
Zero-sequence impedance at a conductor temperature of 20 °C
Zero-sequence impedance at a conductor temperature of 20 °C
Zero-sequence impedance at an ambient air temperature of 35 °C
Zero-sequence impedance at an ambient air temperature of 35 °C
Zero-sequence impedance at an ambient air temperature of 35 °C
Resistances and Reactances
Resistance at a conductor temperature of 20 °C
Resistance at a conductor temperature of 20 °C
Resistance at a conductor temperature of 20 °C
Resistance at a conductor temperature of 20 °C
Resistance at an ambient air temperature of 35 °C
Resistance at an ambient air temperature of 35 °C
Resistance at an ambient air temperature of 35 °C
Resistance at an ambient air temperature of 35 °C
Reactance (Independent from temperature)
Reactance (Independent from temperature)
Reactance (Independent from temperature)
Reactance (Independent from temperature)
All phase conductor characteristics had been determined according to Annex BB of IEC 61439-6.
Fault-loop zero-sequences impedances had been determined according to Annex CC of IEC 61439-6.
Fault-loop resistances and reactances had been determined according to Annex DD of IEC 61439-6.
4
DABLINE
Coding System
BUSBAR
BUSBAR RATING
CONDUCTOR CONFIGURATION
COMPONENTS
DAB
06
04 -
S
T
Busbar Type
D
Components
Standard Length
63 A
80 A
E L E K T R İ K
Busbar Rating
06
08
2 Conductors (Coloured Grey) 02
3 Conductors (Coloured Red) 03
4 Conductors (Coloured Yellow) 04
5 Conductors (Coloured Blue) 05
5 Conductors (Coloured Lilac) 06
STD
Feeder Box
B1
Flexible Elbow
ED
Conductor
Configuration
Conductor Configuration
COLOURED GREY - 02
N
L
PE
COLOURED RED - 03
CE
N
L
PE
COLOURED YELLOW - 04
N
L3 L2 L1
PE
COLOURED BLUE - 05
CE N2 L2 N1 L1
PE
COLOURED LILAC - 06
CE
N
L3 L2 L1
L+N+PE(Housing)
L+N+CE+PE(Housing)
3L+N+PE(Housing)
Monophase System
Low Noise / Clean Earth
3 Phase System
Dual Circuit Busbar
3 Phase / Clean Earth
Addressable Pins
Addressable Pins
Addressable Pins
Addressable Pins
Addressable Pins
PE
2L+2N+CE+PE(Housing) 3L+N+CE+PE(Housing)
5
DABLINE
Busbar System / Order Codes
E L E K T R İ K
Busbar Systems (63A)
Busbar Length (mm)
1200
Description
2400
3000
Number of Plug-in Points (pc)
2
3
4
7
5
9
DAB 0602 - STD Coloured Grey
3046574
3046576
3046587
3046588
3046597
3046598
DAB 0603 - STD Coloured Red
3046577
3046580
3046589
3046590
3046599
3046600
DAB 0604 - STD Coloured Yellow
3046581
3046582
3046591
3046592
3046601
3046602
DAB 0605 - STD Coloured Blue
3046583
3046584
3046593
3046594
3046604
3046606
DAB 0606 - STD Coloured Lilac
3046585
3046586
3046595
3046596
3046607
3046608
Busbar Systems (80A)
Busbar Length (mm)
1200
Description
2400
Number of Plug-in Points (pc)
2
3
4
7
5
9
DAB 0802 - STD Coloured Grey
3036230
3036231
3036238
3036239
3036246
3036247
DAB 0803 - STD Coloured Red
3036232
3036233
3036240
3036241
3036248
3036249
3036251
DAB 0805 - STD Coloured Blue
3036252
3036253
DAB 0806 - STD Coloured Lilac
3036272
3036273
3036274
3036275
3036276
3036277
X=Distance between plug-in outlets
Note : Please call us for non-standard
ndard busbar length and distance between plug-in outlets.
X=300
3036250
X=600
3036243
3036245
X=300
3036242
3036244
X=600
X
3036235
3036237
X=300
3036234
3036236
X=600
DAB 0804 - STD Coloured Yellow
Adjustable Fixing Bracket
2 pcs supplied on 1200mm straight length
2 pcs supplied on 2400mm straight length
3 pcs supplied on 3000mm straight length
6
3000
DABLINE
Feed Boxes / Elbows
E L E K T R İ K
Code
B1- Feed Box
Description
(63A)
(80A)
B1 Coloured Grey
L+N+PE(Housing)
3046609
3036267
B1 Coloured Red
L+N+CE+PE(Housing)
3046611
3036268
B1 Coloured Yellow
3L+N+PE(Housing)
3046612
3036269
B1 Coloured Blue
2L+2N+CE+PE(Housing)
3046613
3036270
B1 Coloured Lilac
3L+N+CE+PE(Housing)
3046614
3036278
195
47,2
92
246,5
Ø25
ED - Flexible Elbow
Code
Conduit
Description
Steel Plastic
(63A)
(80A)
ED Coloured Grey
3046615 3035918
L+N+PE(Housing)
3046620 3035931
ED Coloured Red
3046616 3035919
L+N+CE+PE(Housing)
3046621 3035932
ED Coloured Yellow
3046617 3035920
3L+N+PE(Housing)
3046622 3035933
ED Coloured Blue
3046618 3035921
2L+2N+CE+PE(Housing)
3046623 3035934
ED Coloured Lilac
3046619 3036279
3L+N+CE+PE(Housing)
3046575 3036280
840 (max.)
195
775 (max.)
410 (max.)
92
246,5
47,2
Ø25
7
DABLINE
Plugs
E L E K T R İ K
83
45,5
120,5
DAB 13 - B
DAB 32 - B
DAB 13 - S
Tap Off Plugs (Unfused and Complete with 6x25 Fuse BS 1362 )
(5)
Type
(2)
Conduit
(3)
(4)
L3
N
PE
2 conductors
Coloured Red
L3
N
CE PE
3 conductors
L1
N
N
L2
PE
PE
Coloured
5m LSF Cable
(3)
Unfused
Fused
13A
Coloured Grey
(5)
3m LSF Cable
(1)
Conductor
Configuration
(4)
13A
Unfused
Fused
(4)
32A
(4)
(4)
13A
13A
(4)
32A
Steel
3036260
3036256
3036254
3036261
3036257
3036255
Plastic
3034631
3034613
3034617
3034632
3034614
3034618
Steel
3035929
3036262
3036258
3035930
3036263
3036259
Plastic
3034633
3034615
3034619
3034634
3034616
3034620
Steel
3035744
3035972
3036029
3035756
3035978
3036032
Plastic
3035748
3035975
3034621
3035760
3035981
3034622
Steel
3035745
3035973
3036030
3035757
3035979
3036033
Plastic
3035749
3035976
3034623
3035761
3035982
3034624
Steel
3035746
3035974
3036031
3035758
3035980
3036034
Plastic
3035750
3035977
3034625
3035762
3035983
3034626
Steel
3035747
3036035
3036264
3035759
3036037
3036265
Plastic
3035751
3036036
3034627
3035763
3036038
3034628
Steel
3046665
3046667
3046669
3046671
3046673
3046675
Plastic
3046666
3046668
3046670
3046672
3046674
3046676
Steel
3046677
3046679
3046681
3046683
3046685
3046687
Plastic
3046678
3046680
3046682
3046684
3046686
3046688
Steel
3035752
3036039
3036266
3035764
3036041
3036271
Plastic
3035753
3036040
3034629
3035765
3036042
3034630
Steel
3035960
3035948
3035936
3035962
3035950
3035938
Plastic
3035961
3035949
3035937
3035963
3035951
3035939
Steel
3035964
3035952
3035940
3035966
3035954
3035942
Plastic
3035965
3035953
3035941
3035967
3035955
3035943
Yellow
L3
4 conductors
L1
L1
L2
N
L3
N
PE
PE
N1
Coloured Blue
PE
L2
N2
CE PE
5 conductors
L1
N1 L2
N2
L1
N
N
L2
CE PE
CE PE
CE PE
Coloured Lilac
5 conductors
L3
L1
L2
L3
N
N
CE PE
CE PE
1- PE = Housing
CE = Isolated Clean Earth
Please call us for non-standard phase sequence.
Steel
3035968
3035956
3035944
3035970
3035958
3035946
Plastic
3035969
3035957
3035945
3035971
3035959
3035947
Steel
3035754
3036043
3036281
3035766
3036045
3036283
Plastic
3035755
3036044
3036282
3035768
3036046
3036284
3- with 13A 6x25 BS1362 Fuse
2
4- 13A Plug with 1,5mm Cross Section Cable
2
32A Plug with 4mm Cross Section Cable.
2- Zinc Plated Steel Conduit
P6 V0 halogen free Plastic Conduit
8
5- LSF: Low Smoke, Fume
DABLINE
Tap Off Boxes
E L E K T R İ K
89,2
106,2
223
116,6
Tap Off Boxes (Unfused ,with MCB and Complete with 10x38 Fuse)
(4)
32A
(1)
Type
Conductor
Configuration
(2)
Conduit
(5)
3m LSF Cable
Unfused
L3 N
Coloured Grey
PE
Plastic
L3 N CE PE
Coloured Red
Plastic
N
L1
PE
Plastic
N
PE
Plastic
Yellow
L3 N
4 conductors
PE
Plastic
PE
Plastic
PE
L1 N1
Plastic
L2 N2 CE PE
Coloured Blue
5 conductors
Plastic
L1 N1 L2 N2 CE PE
Plastic
N CE PE
L1
Plastic
N CE PE
Plastic
5 conductors
L3 N CE PE
Plastic
3035927 3034688 3034723
3034655 3034689 3034724 3034656 3034690 3034725
3034657 3034691 3034726 3034658 3034692 3034727
3046701 3046702 3046703
3046689 3046691 3046693 3046695 3046697 3046699
3046690 3046692 3046694 3046696 3046698 3046700
3046716 3046717 3046718
3046704 3046706 3046708 3046710 3046712 3046714
3046705 3046707 3046709 3046711 3046713 3046715
3035928 3034693 3034728
3034659 3034694 3034729 3034660 3034695 3034730
3034661 3034696 3034731 3034662 3034697 3034732
3035984 3035986 3035985
3035987 3035989 3035988 3035993 3035995 3035994
3035990 3035992 3035991 3035996 3035998 3035997
3035999 3036001 3036000
3036002 3036004 3036003 3036008 3036010 3036009
3036005 3036007 3036006 3036011 3036013 3036012
3036014 3036016 3036015
3036017 3036019 3036018 3036023 3036025 3036024
3036020 3036022 3036021 3036026 3036028 3036027
----Steel
Plastic
1- PE = Housing
3035926 3034683 3034718
3034651 3034684 3034719 3034652 3034685 3034720
3034653 3034686 3034721 3034654 3034687 3034722
----Steel
L1 L2 L3 N CE PE
3035925 3034678 3034713
3034647 3034679 3034714 3034648 3034680 3034715
3034649 3034681 3034716 3034650 3034682 3034717
----Steel
Coloured Lilac
3035924 3034673 3034708
3034643 3034674 3034709 3034644 3034675 3034710
3034645 3034676 3034711 3034646 3034677 3034712
----Steel
L2
3035923 3034668 3034703
----Steel
with MCB
3034639 3034669 3034704 3034640 3034670 3034705
3034641 3034671 3034706 3034642 3034672 3034707
----Steel
(3)
3035922 3034663 3034698
----Steel
Fused
3034635 3034664 3034699 3034636 3034665 3034700
3034637 3034666 3034701 3034638 3034667 3034702
----Steel
Without Cable
with MCB Unfused
----Steel
L1 L2 L3 N
(3)
----Steel
Coloured
Fused
----Steel
L2
with MCB Unfused
----Steel
3 conductors
(3)
----Steel
2 conductors
Fused
(5)
5m LSF Cable
3036285 3036287 3036286
3036288 3036290 3036289 3036294 3036296 3036295
3036291 3036293 3036292 3036297 3036299 3036298
2- Zinc Plated Steel Conduit
3- 32A 10x38 Fuse
CE = Isolated Clean Earth
P6 V0 halogen free Plastic Conduit
2
4- 32A Tap-off Box with 4mm Cross Section Cable.
Please call us for non-standard
Ø20 outer diameter Conduit
5- LSF: Low Smoke, Fume
phase sequence.
9
DABLINE
Joint Coupler Installation
E L E K T R İ K
2
1
1- Remove the plastic cover which is protecting
jaw contacts of Joint Coupler before to start
installation.
2- To join two busbar lengths as shown in the picture
left, the additional module alignment pin should be
aligned with the slot in the other window.
3
3- Push home the Joint Coupler alignment pin into the slot on the other window.
4
K
CLIC
K
CLIC
K
CLIC
4- Ensure that the Joint Coupler claws, clip over the busbar body. (Joint coupler will not release after being clicked
into place)
5
10
Nm
5- Tighten the main bolt of the joint pack to10Nm
using a torque wrench.
10
DABLINE
Plug Installation
E L E K T R İ K
1
K
CLIC
1- Open the socket cover.
2
2- Insert the alignment pins of the Plug into the busbar
alignment holes.
3
3- Ensure that the plug arms firmly grip the body of
the busbar.
K
CLIC
K
CLIC
WARNING:
* For your safety, do not cut the plug alignment pins, do not remove and do not
changed their correct locations.
* The plug cable connections must be completed before connecting the plug to
the busbar.
* Ensure that the load being supplied is in the ''OFF'' position.
11
DABLINE
Feeder Box Installation
E L E K T R İ K
2
1
2- Protected cable should be used using the
appropriate gland to complete the connection.
1- Remove the Feed Box cover by undoing
the screws.
3
3- Fix the cables to the terminals making sure that the terminals are fully tightened.
4
4- Complete the installation process by tightening the cable gland.
5
WARNING:
Ensure that the cable is not energised
before starting the installation and the
load supplied must be in the ''OFF''
position.
5- Refit the Feed Box cover by replacing the screws
as shown.
12
DABLINE
Busbar System Installation
E L E K T R İ K
1
1- Mark out the route of busbar system
where it will run . Make sure that, the
line is clearly marked.
2
2- To join the two busbar lengths
as shown in the picture left,
the additional module
alignment pin should be
aligned with the slot in the
other window.
3
10
Nm
3- Tighten the Joint Coupler
main bolt to 10Nm using
a torque wrench .
4
4- Fix the busbar systems to
the base with the retractable
support system.
13
Raised-Off Floor
Fixing Bracket
21mm
Feed Box
(130x230x21mm)
216
Ø4,6
Order Code : 2025101
Raised-Off Floor
Fixing Bracket (Long)
3-) The total height of plug or coupler
with Raised-Off Floor Fixing Bracket
is max.70mm.
2-) Make sure Raised-Off Floor Fixing
Brackets are fully secured to floor.
Raised-Off Floor Fixing Bracket Installation Manual
(2025100 - 2025101)
Order Code : 2025100
Raised-Off Floor
Fixing Bracket (Short)
94
Ø4,6
230
Ø 7mm
(130x94x21mm)
80
2025100 Raised-Off Floor
Fixing Bracket (Short)
1-) Make sure the busbar line is fixed to
Raised-Off Floor Fixing Bracket as
shown on the picture.
Distance between removable
fixing brackets are 600mm
RAISED SUPPORT FIXING BRACKET DETAILS
2025101 Raised-Off Floor
Fixing Bracket (Long)
Movable Support
Coupler Module
Busbar
116
21
14
21
Screws are supplied with
Raised-Off Floor Fixing Bracket
DABLINE
E L E K T R İ K
116
DABLINE
Applications
E L E K T R İ K
Advantages:
Can be used in raised floor voids as low as
50mm in Office environments
Suitable for to use in Data Control systems
Easy mounting
Up to 32 A outlet options
Easy assembly with single bolt joint coupler
Different Pin Codings for different types of
busbar systems
Different lengths of busbar can be achieved
The contacts of the Tap-offs are silver plated
Application Areas:
Banks
Shopping Centres
New Generation Offices
Hotels
Hospitals
Conference Centres
Educational Buildings
Cinemas and theatres
Tourist Facilities etc.
3m
Sample DABLINE Installation
6m
6m
Socket outler every 300mm or 600mm
(depends on length of busbar and the number of outlets required)
E-Line DK
Floor Box
Tap-off plug13A or 32A
6m
Feed Box
Busbar support
15
DABLINE
Product Overview
E L E K T R İ K
PRODUCT OVERVIEW (DABLINE)
Busbar Systems;
shall have a type test report according to IEC 61439-6. The type test reports shall be from an internationally
accepted third party laboratory.
The Plug-in Busbar system shall have one of the following conductor number and configurations;
a) 2 conductors : L / N / PE (Housing) COLOURED GREY
b) 3 conductors : L / N / CE / PE ( Housing) COLOURED RED
c) 4 conductors : L1 / L2 / L3 / N / PE (Housing) COLOURED YELLOW
d) 5 conductors: L1 / N1 / L2 / N2 / CE / PE (Housing) COLOURED BLUE
e) 5 conductors: L1 / L2 / L3 / N / CE / PE (Housing) COLOURED LILAC
The housing shall be used as the earth conductor.
The rated insulation voltage of the system shall be 690 V, shall have a rated current level of 63 and 80A, 50Hz.,shall have tin
plated copper conductors.
shall be produced as 1.2m, 2.4m and 3m straight lengths and there shall be plug-in outlets every
30cm or 60cm (optional) with IP55 protection plug-in outlet covers.
IP protection degree of the busbars shall be 55.
The housing of the busbar shall be manufactured from 0,60mm thick, epoxy painted ( RAL 7038 ), galvanised sheet metal.
The Support system shall be moveable and suitable for the busbar structure. Adjustable Fixing Bracket system shall be supplied as
part of the busbar.
Total height of the busbar system with all components shall be 49mm.
The joint contact module shall provide continuous earth protection along the whole busbar line.
The plug-in outlets shall be colour coded the same as the tap-offs to prevent incorrect connection of different types of busbars.
Busbar Systems Conductors;
In the housing shall be continuously insulated and only exposed at the plug-in points to create the contact area.
shall be of electrolytic copper and continuously tin plated.
Busbar joint contact points shall be silver plated.
Busbar Systems Outlet Plugs;
Contacts of the tap-offs shall be of jaw structure, which contacts the conductors on both sides. The contacts shall have springs.
The Tap-off Cable shall be to BS 7211.
The Tap-off conduit shall be steel and to BS 6231 standard.
The tap-off plugs shall have different colours and be addressable using pins for different types of busbar configuration.
Busbar Systems Dimensions
X=300 - 600
2xØ25
16
49
124,5
18,5
202
44
47,5
92
92
300
X=300 - 600
72
300
120
Compact Busbar Distribution System
630...6300 A
E-LINE CR
Compact Busbar Distribution System
630...6300 A
Compact Busbar Distribution System
800...6300 A
Plug-in Busbar Distribution System
160...800A
Small Power Plug-in Busbar Distribution System
100-160-225A
Plug-in Busbar Distribution System
40-63A
Multi-Conductor Lighting Busbar System
25-32-40A
Lighting Busbar System
25-32-40A
Multi Conductor Trolley Busbar System
35...250A
Underfloor Ducting Systems
Cable Tray Systems, Cable Ladder Systems,
Binrak (Unistrut) and Tray Support Systems
Y A N D EN V
IT
AL
E
QU
ME 04
ISO
9001
14001
S
s
MENT SYSTE
M
T
MENTAL MAN
ON
E
AG
IEC 61439-6
IR
EAE Elektrik A.Ş.
Akcaburgaz Mahallesi,
119. Sokak, No:10 34510
Esenyurt-Istanbul-TURKEY
Tel: +90 (212) 866 20 00
Fax: +90 (212) 886 24 20
www.eae.com.tr
Catalogue 16-Eng. / Rev 02 1000 pcs. 03/12/2013
ATA LTD. / A.C.E./ 612 40 66
EAE has full right to make any revisions or changes on this catalogue without any prior notice.
Download