Valve regulated lead-acid batteries

advertisement
OPzV
Motive Power Systems
Reserve Power Systems
Valve regulated lead-acid
batteries
Special Power Systems
Service
Your benefits with HOPPECKE OPzV
n
Maintenance-free regarding water refilling - due to innovative Gel-technology
n
Very high expected service life - due to optimized lead-calcium alloy
n
Very high cycle stability - due to tubular plate design
n
Maximum compatibility - design according to DIN 40742
n
Optimal space utilization - due to possibility of horizontal arrangement1
n
Higher short-circuit safety even during the installation - based on HOPPECKE system connectors
Typical applications
of HOPPECKE OPzV
Telecommunications
Mobile phone stations
BTS-stations
Off-grid/on-grid solutions
n
Traffic systems
Signalling
Lighting
n
Similar to the illustration
n
Security lighting
OPzV
Type Overview
Capacities, dimensions and weights
C5/1.77 V
Ah
C3/1.75 V
Ah
C1/1.67 V
Ah
max.* Weight
kg
4 OPzV 200 (*)
5 OPzV 250 (*)
6 OPzV 300 (*)
5 OPzV 350 (*)
6 OPzV 420 (*)
7 OPzV 490 (*)
6 OPzV 600 (*)
8 OPzV 800 (*)
9 OPzV 900 (*)
10 OPzV 1000 (*)
11 OPzV 1100 (*)
12 OPzV 1200 (*)
12 OPzV 1500 (*)
14 OPzV 1750
16 OPzV 2000
18 OPzV 2250
20 OPzV 2500
22 OPzV 2750
24 OPzV 3000
200
250
300
350
420
490
600
800
900
1000
1100
1200
1500
1750
2000
2250
2500
2750
3000
213
267
320
412
494
577
718
958
1080
1200
1320
1440
1570
1832
2090
2355
2620
2878
3140
199
248
298
365
438
510
625
835
938
1040
1146
1250
1315
1532
1750
1969
2190
2407
2625
183
228
274
324
387
453
543
723
815
906
995
1086
1146
1339
1530
1721
1911
2104
2295
141
177
212
236
283
330
388
517
581
646
710
775
795
927
1059
1192
1324
1457
1589
18.3
22.3
26.5
29.9
35.1
42.1
48.7
65.9
75.6
80.5
89.3
94.6
110.0
136.5
152.9
173.0
186.5
214.7
222.3
max.* Length L max.* Width W max.* Height H
mm
mm
mm
105
126
147
126
147
168
147
215
215
215
215
215
215
215
215
215
215
215
215
208
208
208
208
208
208
208
193
235
235
277
277
277
400
400
490
490
580
580
420
420
420
535
535
535
710
710
710
710
710
710
855
815
815
815
815
815
815
Fig.
A
A
A
A
A
A
A
B
B
B
B
B
B
C
C
D
D
D
D
Cnom = nominal capacity at 10 h discharge according to DIN 40742
C10, C5, C3 and C1 = Capacity at 10 h, 5 h, 3 h and 1 h discharge
(*)
= horizontal operation possible
* according to DIN 40742 data to be understood as maximum values
Fig. D
H
Fig. C
Fig. B
W
W
W
W
Fig. A
L
L
L
4 OPzV 200 6 OPzV 600
8 OPzV 800 12 OPzV 1500
L
16 OPzV 2000
20 OPzV 2500 24 OPzV 3000
Design life: up to 20 years
Optimal environmental compatibility - closed loop for recovery of materials in an accredited recycling system
1
Operating in a horizontal position is only possible with special OPzV variant. Please consider when ordering!
HOPPECKE Batterien GmbH & Co. KG
P.O. Box 1140 · D-59914 Brilon · Germany
Bontkirchener Straße 1 · D-59929 Brilon-Hoppecke
Phone +49(0)2963 61-374
Fax
+49(0)2963 61-270
Email info@hoppecke.com
www.hoppecke.com
All details in this brochure are based on state-of-the-art technology. Our products are subject to constant development. We therefore reserve the right to make changes.
C10/1.80 V
Ah
Printed in Germany
Cnom/1.80 V
Ah
Form OPzV EN/02.14/1 K