EMERGENCY STOP Switchgears, Safety Gate Monitors Category 4, EN 954-1 PNOZ X3P Technical data Electrical data Supply voltage Tolerance Power consumption Voltage and current at input, start and feedback loop Switching capability according to EN 60947-4-1, 02/01 EN 60947-5-1, 11/97 (DC13: 6 switching cycles/min) Output contacts EMERGENCY STOP switchgear and safety gate monitor according to VDE 0113, 11/89, EN 60204-1, 12/97 and IEC 204-1, 11/98. Contact protection according to EN 60947-5-1, 11/97 Semiconductor output external power supply Times Pickup delay Features Delay-on de-energisation ● Either monitored or automatic start possible ● 1 semi-conductor output (K1/K2) ● Power supply 24 V DC and 24 V AC contained in every device ● Safety gate function with NC/NO combination ● 2-channel wiring only with shorts across contacts detection ● Plug-in terminals Recovery time Simultaneity channel 1/2 Power failure buffer Environmental data Ambient temperature EMC Mechanical data Max. cross section of outer conductor single wire multi-wire (2 wires of same cross section) Approvals PNOZ X3P ● ● ● Torque setting for terminals Dimensions (H x W x D) Weight Description ● 45 mm P-99-housing, on standard rail, snap-on ● Relay outputs, positive-guided: – 3 safety contacts (NO), – 1 auxiliary contact (NC) ● Connection possibilities for – EMERGENCY STOP button – Safety gate limit button – Start button ● Semi-conductor output signals ready for operation Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de PNOZ X3P 24 V AC, 24 V DC 85 ... 110 % max. 5 VA/approx. 2,5 W 24 V DC, 35 mA AC1: 240 V/8 A/2000 VA DC1: 24 V/8 A/200 W AC15: 230 V/5 A DC13: 24 V/6 A 3 safety contacts (NO), 1 auxiliary contact (NC) 10 A quick-acting or 6 A slow-acting 24 V DC/20 mA, short-circuit-proof 24 V DC ±20 % monitored start: max. 100 ms auto./man. start: max. 0.3 s at EMERGENCY STOP: max. 80 ms at mains off: max. 1 s approx. 1 s ¥ approx. 25 ms -25 ... +55 °C EN 50081-1, 01/92; EN 61000-6-2, 04/99 flexible without end sleeve: 0.2 ... 2.5 mm2 flexible with end sleeve: 0.25 ... 2.5 mm2 flexible with end sleeve without plastic sleeve: 0.25 ... 1 mm2 flexible with TWIN end sleeve with plastic sleeve: 0.5 ... 1.5 mm2 0.5 ... 0.6 Nm (screws) 94 x 45 x 122 mm 270 g ● LEDs for switching status Channel 1, channel 2 and supply voltage ● Contact multiplication and contact amplification possible by external contactors Operating modes ● ● ● ● Single channel mode Dual channel mode Automatic start Manual start with monitoring NSG-D-2-161-08/02 1 EMERGENCY STOP Switchgears, Safety Gate Monitors Category 4, EN 954-1 PNOZ X3P ● Example 5 Dual-channel safety gate control with monitored start Schematic interior diagram UB A1 A2 Auxiliary Safety contacts contacts 13 23 33 41 Start/feedback loop Input loop S33 S34 S14 S13 S11 S12 S31 S32 S11 S33 S21 S1 K1 CH2 Y30 Start Unit S22 S31 CH1 S3 S2 K2 Y31 S32 Y32 & S21 Input Inputloop loop 14 24 34 42 S22 S12 S34 ● Example 6 Dual-channel safety gate control with automatic start S21 S13 S11 External wiring ● Example 1 Single-channel EMERGENCY STOP wiring with automatic start S21 S31 S11 S11 S31 S21 S13 S22 S31 S2 S33 S1 S1 S1 ● Example 3 Dual-channel EMERGENCY STOP wiring with monitored start S32 S14 S12 – Legend S3 S1/S2: EMERGENCY STOP or safety gate switch S3: Start button S12 S32 S22 S14 S22 S32 S12 S34 actuated element ● Example 2 Single-channel EMERGENCY STOP wiring with monitored start S11 S31 S21 S33 S1 ● Example 4 Single-channel safety gate control with monitored start gate not closed gate closed S11 S21 S31 S33 S1 S3 S12 S32 S22 S34 S3 S12 S22 S32 S34 Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de NSG-D-2-161-08/02 EMERGENCY STOP Switchgears, Safety Gate Monitors Category 4, EN 954-1 PNOZ X3P ● Contact multiplication The output contacts can be amplified or multiplied by external contactors with positive-guided contacts if necessary. 1 – Single-channel control with automatic start 1L1 K6 K5 S13 S14 13 14 K5 K6 1L2 – Single-channel control with monitored start 1L1 K6 S3 K5 S33 S34 13 14 K5 K6 1L2 Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de NSG-D-2-161-08/02 EMERGENCY STOP Switchgears, Safety Gate Monitors Category 4, EN 954-1 PNOZ X3P General data Unless described otherwise than the device-specific technical data. Electrical data Frequency range AC Residual ripple DC Contact material Continuous duty Environmental data EMC Oscillations according to EN 60068-2-6, 01/00 Environmental conditions Airgap and creepage distance Ambient temperature Storage temperature Mechanical data Torque setting for terminals Mounting position Housing material Protection types 50 ... 60 Hz 160 % AgSnO2 100 % EN 50081-1, 01/92; EN 61000-6-2, 03/00 Frequency: 10 ... 55 Hz, Amplitude: 0.35 mm DIN IEC 60068-2-3, 12/86 DIN VDE 0110-1, 04/97 -10 ... +55 °C -40 ... +85 °C 0.6 Nm (screws) any Thermoplast Noryl SE 100 Installation room: IP 54 Housing: IP 40 Terminals: IP 20 The units were tested in accordance with the relevant standards current at the time of development. Order References Type PNOZ X3P UB 24 V DC, 24 V AC Pilz GmbH & Co., Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de Order No. 777 310 NSG-D-2-161-08/02