™ DC CCTV Power Supplies Installation Guide Models Include: Sav4D - 12VDC @ 5 amp - Four (4) Class 2 Rated PTC Protected Power-Limited Outputs. Sav9D - 12VDC @ 5 amp - Nine (9) Class 2 Rated PTC Protected Power-Limited Outputs. Sav18D - 12VDC @ 5 amp - Eighteen (18) Class 2 Rated PTC Protected Power-Limited Outputs. Sav182D - 12VDC @ 11 amp - Eighteen (18) Class 2 Rated PTC Protected Power-Limited Outputs. Sav36D - 12VDC @ 11 amp - Thirty-Six (36) Class 2 Rated PTC Protected Power-Limited Outputs Rev. 070709 More than just power.™ Overview: Altronix Sav Power Supplies provide 12VDC distributed via four (4), nine (9), eighteen (18), thirty-six (36) Class 2 Rated PTC protected power-limited outputs for powering Surveillance Cameras and other 12VDC devices. Sav4D 5 amp 12VDC 4 2.5 amp* 1.5 amp 0.75 amp Sav9D 5 amp 12VDC 9 2.5 amp* 1.5 amp 0.75 amp Sav18D 5 amp 12VDC 18 2.5 amp* 1.5 amp 0.75 amp Sav182D 11 amp 12VDC 18 2.5 amp* 3 amp 1.5 amp Sav36D 11 amp 12VDC 36 2.5 amp* 3 amp 1.5 amp UL Listings and File Numbers Agency Listings 230VAC 50Hz Input Current 115VAC 60Hz Input Current Output Current (max per output) Number of Class 2 Rated PTC Protected PowerLimited Outputs Output Voltage Total Output Current (Power) Altronix Model Number Sav Reference Chart: UL Listed for Commercial CCTV Equipment (UL 2044). CUL Listed - CAN/CSA C22.2 No. 1-04, Audio, Video and Similar Electronic Equipment. *Not to exceed total output current. 230VAC/50Hz operation is intended for use outside of the North American Markets only. Input: Specifications: Features (cont’d): • 115VAC 60Hz or 230VAC 50Hz. Output: • 12VDC outputs. (1.2 amp per device, 2.5 amp max.). • four (4), nine (9), eighteen (18) or thirty-six (36) Class 2 Rated PTC protected power-limited outputs • Filtered and electronically regulated outputs. • Short circuit and thermal overload protection. Features: • Four (4) power LEDs. • Power ON/OFF switch. • Field installable 3-wire line cord with integral strain relief. • Unit maintains camera synchronization. • Ease of installation saves time and eliminates costly labor. Enclosure Dimensions (H x W x D approx.): • Sav4D, Sav9D and Sav18D: 8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm). • Sav182D and Sav36D: 13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm). Installation Instructions: This installation should be made by qualified service personnel and should conform to all local codes and in accordance with the National Electrical Code. Product is intended for indoor use only. 1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install two fasteners. Place the enclosure’s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pgs. 11-12). 2. SAV4D, SAV9D and SAV18D: Connect unswitched AC power 115VAC, 60 Hz / 230VAC, 50 Hz to Fig. 1 the removable terminals marked [L, G, N] (Fig. 1, pg. 2). SAV182D and SAV36D: Connect unswitched AC power 115VAC, 60 Hz / 230VAC, 50 Hz to black and white flying leads, which are factory installed. Connect main incoming ground to the provided green grounding conductor lead. To install 3-wire line cord with integral strain relief (supplied) refer to pages 9 and 10. 3. Unit is factory set at 12VDC. To adjust output voltage use the trimpot (Fig. 2a pg. 4, 3a pg. 5, 4a pg. 6, 5a pg. 7, 6a, pg. 8) on the power supply board(s), connect digital volt meter to the terminals marked [OUT1 to OUT18] and slowly - 2 - Sav4/9/18/182/36D turn trimpot clockwise to increase voltage or counter clockwise to decrease voltage. Note: Voltage will be the same for all outputs. 4. Measure output voltage before connecting devices. This helps avoiding potential damage. 5. Connect cameras to be powered to the terminals marked [OUT1 through OUT4 (Sav4D)] (Fig. 2, pg. 4), [OUT1 through OUT9 (Sav9D)] (Fig. 3, pg. 5), [OUT1 through OUT18 (Sav18D)] (Fig. 4, pg. 6), [OUT1 through OUT9 on eachpower supply board (Sav182D)] (Fig. 5, pg. 7), [OUT1 through OUT18 on each power supply board (Sav36D)] (Fig. 6, pg. 8), carefully observing correct polarity. 6. Upon completion of wiring, secure enclosure door with screws (supplied). Caution: Equipment to be installed/serviced by authorized/trained personnel only and should conform to all local codes and in accordance with the National Electrical Code. Shut branch circuit power before installing/servicing equipment. WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. Use 75˚C or higher rated UL insulated wiring for connecting the unit to the mains. Maintenance: Unit should be tested at least once a year for the proper operation as follows: Output Voltage Test: Under normal load conditions, the DC output voltage should be checked for proper voltage level. Terminal Identification: Model All Sav4D Sav9D Sav18D Sav182D Sav36D Terminal Legend L, G, N OUT1 (-- , +) through OUT4 (-- , +) OUT1 (-- , +) through OUT9 (-- , +) OUT1 (-- , +) through OUT18 (-- , +) OUT1 (-- , +) through OUT9 (-- , +) (on both power supply boards) OUT1 (-- , +) through OUT18 (-- , +) (on both power supply boards) Description 115VAC, 60 Hz / 230VAC, 50 Hz Input 12VDC power output. LED Identification: Model All Sav4D Sav9D Sav18D Sav182D Sav36D LED AC OUT1 through OUT4 OUT1 through OUT9 OUT1 through OUT18 OUT1 through OUT9 (on both power supply boards) OUT1 through OUT18 (on both power supply boards) Sav4/9/18/182/36D ON Normal operating condition. OFF Loss of AC, No DC output Normal operating condition. No Power Output. -3- Sav4D Fig. 2 115VAC, 60Hz/ 230VAC, 50Hz power mains non powerlimited Class 1 Wire Strap (from Enclosure to Door) Green Lead Fig. 2a Voltage Adjustment 12VDC power outputs (For wiring utilize knockouts on the right hand side of enclosure) Class 2 not wet, Class 3 wet, wiring to be used. Door Keep power-limited wiring separate from non power-limited. Use minimum 0.25" spacing. The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. - 4 - CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel. Sav4/9/18/182/36D Sav9D Fig. 3 115VAC, 60Hz/ 230VAC, 50Hz power mains non powerlimited Class 1 Wire Strap (from Enclosure to Door) Green Lead Fig. 3a Voltage Adjustment 12VDC power outputs (For wiring utilize knockouts on the right hand side of enclosure) Class 2 not wet, Class 3 wet, wiring to be used. Door Keep power-limited wiring separate from non power-limited. Use minimum 0.25" spacing. Sav4/9/18/182/36D -5- Sav18D Fig. 4 115VAC, 60Hz/ 230VAC, 50Hz power mains non powerlimited Class 1 Wire Strap (from Enclosure to Door) Green Lead Fig. 4a Voltage Adjustment 12VDC power outputs (For wiring utilize knockouts on the right hand side of enclosure) Class 2 not wet, Class 3 wet, wiring to be used. Door Keep power-limited wiring separate from non power-limited. Use minimum 0.25" spacing. - 6 - Sav4/9/18/182/36D Sav182D Fig. 5 115VAC, 60Hz / 230VAC, 50Hz power mains non power-limited Class 1 Green Lead Black Lead 12VDC power outputs (For wiring utilize knockouts on the left hand side of enclosure) 12VDC power outputs (For wiring utilize knockouts on the right hand side of enclosure) Class 2 not wet, Class 3 wet, wiring to be used. Fig. 5a White Lead Class 2 not wet, Class 3 wet, wiring to be used. Voltage Adjustment Keep power-limited wiring separate from non power-limited. Use minimum 0.25" spacing. Sav4/9/18/182/36D -7- Sav36D Fig. 6 115VAC, 60Hz / 230VAC, 50Hz power mains non power-limited Class 1 Green Lead Black Lead 12VDC power outputs (For wiring utilize knockouts on the left hand side of enclosure) White Lead 12VDC power outputs (For wiring utilize knockouts on the right hand side of enclosure) Class 2 not wet, Class 3 wet, wiring to be used. Class 2 not wet, Class 3 wet, wiring to be used. Fig. 6a Voltage Adjustment Keep power-limited wiring separate from non power-limited. Use minimum 0.25" spacing. - 8 - Sav4/9/18/182/36D Installation Instructions for 3-wire Line Cord: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. The line cord option should be used when the equipment needs to be removed for maintenance or servicing. Do not attach the 3-wire line cord to the building surface. 1. Remove 7/8” knockout by applying pressure from the inside of enclosure (Fig. 7). Note: Keep power-limited wiring separate from non power-limited. Use minimum 0.25” spacing. Hog Ring Please refer to the SAV DC Power Supplies Installation Guide’s wiring diagram. 2. Insert AC line cord with integral strain relief through the desired enclosure knockout (Fig. 8). 3. Secure AC line cord by sliding hog ring into strain relief slot inside the enclosure (Figs. 9 and 10). Fig. 7 Fig. 8 7/8” Knockout Fig. 9 Fig. 10 Sav4/9/18/182/36D -9- Wiring AC line cord for models SAV4D, SAV9D and SAV18D: 1. Connect black lead to terminal marked [L]. Connect green lead to terminal marked [G]. Connect white lead to terminal marked [N] (Fig. 11). Fig. 11 White Lead Green Lead Black Lead Wiring AC line cord for models SAV182D and SAV36D: 1. Splice black lead from line cord to black leads from each power supply board utilizing wire nut (Fig. 12). Splice green lead from line cord to green flying lead in the enclosure utilizing wire nut (Fig. 12). Splice white lead from line cord to white leads from each power supply board utilizing wire nut (Fig. 12). Note: To prevent loosening of splices secure each wire nut separately with a few wraps of electrical tape (Fig. 13). Fig. 12 Black Lead White Lead Green Lead To AC Line cord Fig. 13 Electrical Tape Wire Nut - 10 -Sav4/9/18/182/36D Enclosure Dimensions for Sav4D, Sav9D and Sav18D: 8.5” x 7.5” x 3.5” (215.9mm x 190.5mm x 88.9mm) 7.25” (184.15mm) 3.625” (184.15mm) 1.25” (31.75mm) 3.5” (88.9mm) 1.25” (31.75mm) 2” (50.8mm) 0.6” (15.24mm) 0.6” (15.24mm) 6.05” (153.67mm) 1.125” (28.575mm) 1.125” (28.575mm) 2” (50.8mm) 8.125” (206.375mm) 1” (25.4mm) 1” (25.4mm) 6.05” (153.67mm) 0.6” (15.24mm) 0.6” (15.24mm) 1.25” (31.75mm) 3.5” (88.9mm) 1” (25.4mm) 1” (25.4mm) Sav4/9/18/182/36D 5.25” (133.35mm) 1” (25.4mm) - 11 - Enclosure Dimensions for Sav182D and Sav36D: 13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm) 1.40” (36mm) 4.85” (123mm) 4.85” (123mm) 1.40” (36mm) 1.20” (31mm) 3.25” (83mm) 1.20” (31mm) 0.75” (19mm) 12.5” (318mm) 11.0” (279mm) 1.20” (31mm) 0.75” (19mm) 0.9375” (24mm) 1.40” (36mm) 1.40” (36mm) 5.10” (130mm) 5.10” (130mm) 13.0” (330mm) 5.10” (130mm) 6.5625” (167mm) 0.9375” (24mm) 3.25” (83mm) 3.25” (83mm) 3.25” (83mm) 1.0” (25mm) 1.0” (25mm) 1.0” (25mm) 10.5” (267mm) 1.0” (25mm) Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: info@altronix.com, Made in U.S.A. IISAV4D/SAV9D/SAV18D/SAV182D/SAV36DD29O MEMBER - 12 -Sav4/9/18/182/36D