Note: The terms "Unidirectional Path Switched Ring" and "UPSR

advertisement
ONS_SONET_TL1_Command_Guide_R8.5.1_--_Conditions
Note: The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These
terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration.
Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path
protection feature, which may be used in any topological network configuration. Cisco does not recommend
using its path protection feature in any particular topological network configuration.
This chapter describes the conditions for TL1 commands and autonomous messages for the Cisco ONS
15454, Cisco ONS 15310-CL, Cisco ONS 15310-MA, and Cisco ONS 15600.
Conditions include any problem detected on an ONS 15454, ONS 15310-CL, ONS 15310-MA, or ONS
15600 shelf. They can include standing or transient notifications. A snapshot of all currently raised standing
conditions on the network, node, or card can be retrieved in the Cisco Transport Controller (CTC) Conditions
window or using the RTRV-COND commands. (In addition, some but not all cleared conditions are found in
the CTC History tab.)
Table 27-1: Conditions
Condition
AIS
AIS-L
AIS-P
AIS-V
ALS
APC-DISABLED
APC-FAIL
APSB
APSC-IMP
APSCDFLTK
APSCINCON
APSCM
APSCNMIS
APSIMP
APSMM
AS-CMD
AS-MT
AU-LOF
AUD-LOG-LOSS
AUD-LOG-LOW
AUTOLSROFF
AUTORESET
AUTOSW-AIS
AUTOSW-LOP
AUTOSW-PDI
AUTOSW-SDBER
AUTOSW-SFBER
AUTOSW-UNEQ
BAT-FAIL
Table 27-1: Conditions
Description
Alarm Indication Signal
Alarm Indication Signal-Line
Alarm Indication Signal-Path
Alarm Indication Signal-VT
Automatic Laser Shutdown
Automatic Power Control Disabled
Automatic Power Control Failure
Byte Failure
Improper Automatic Protection Switch (APS) Code
Default K Byte
Inconsistent APS Code
Protection Switching Channel Match Failure
Node ID Mismatch
APS Invalid Mode
Automatic Protection Switch Mode Mismatch
Alarms Suppressed By User Command
Alarms Suppressed For Maintenance
Loss of Frame (LOF)-Administration Unit-Loss of Multiframe
Audit Log 100 Percent Full-Oldest records will be lost
Audit Log 80 Percent Full
Automatic Laser Shutoff Due To High Temperature
Automatic System Reset
Automatic Path Protection Switch Caused By AIS
Automatic Path Protection Switch Caused By LOP
Automatic Path Protection Switch Caused By PDI
Automatic Path Protection Switch Caused By SDBER
Automatic Path Protection Switch Caused By SFBER
Automatic Path Protection Switch Caused By UNEQ
Battery Failure
1
ONS_SONET_TL1_Command_Guide_R8.5.1_--_Conditions
BAT-HGH-VLT
BAT-LOW-VLT
BKUPMEMP
BLSROSYNC
CARLOSS
CKTDOWN
CLDRESTART
COMIOXC
COMM-FAIL
CONTBUS-A-18
CONTBUS-B-18
CONTBUS_A
CONTBUS_B
CTNEQPT-MISMATCH
CTNEQPT-PBPROT
CTNEQPT-PBWORK
DATAFLT
DBOSYNC
DS3-MISM
DSP-COMM-FAIL
DSP-FAIL
DUP-IPADDR
DUP-NODENAME
E-W-MISMATCH
EHIBATVG
ELWBATVG
EOC
EOC-L
EQPT
EQPT-MISS
ERFI-P-CONN
ERFI-P-PAYLD
ERFI-P-SRVR
ERROR-CONFIG
ETH-LINKLOSS
EXCCOL
EXERCISE-RING-FAIL
EXERCISE-RING-REQ
EXERCISE-SPAN-FAIL
EXERCISE-SPAN-REQ
EXT
EXTRA-TRAF-PREEMPT
Table 27-1: Conditions
High Volt
Low Volt
Primary Nonvolatile Backup Memory Failure
BLSR Out Of Sync
Carrier Loss On The LAN
Signaling Unable to Set Up Circuit
Cold Restart
Input/Output (IO) Slot To Cross-connect (XCON) Communication
Failure
Plug-in Module Communication Failure
TCC A To DCC A Processor Communication Failure
TCC B To DCC B Processor Communication Failure
Controller A To Shelf Slot Communication Failure
Controller B To Shelf Slot Communication Failure
Connection Equipment Mismatch
Interconnection Equipment Failure-Protect XC Payload Bus
Interconnection Equipment Failure-Working XC Payload Bus
Software Fault-Data Integrity Fault
Standby Database Out of Synchronization
DS3 Frame Format Mismatch
DSP Communication Failure
DSP Failure
IP address already in use within the same data communications
channel (DCC) area
Node name already in use within the same DCC area
Both Ends Of Fiber Provisioned As East Or Both As West
Extreme High Voltage
Extreme Low Voltage
Section DCC (SDCC) Termination Failure
Line DCC (LDCC) Termination Failure
Equipment Failure
Replaceable Equipment/Unit is Missing
Enhanced Remote Failure Indication-Path-Connectivity
Enhanced Remote Failure Indication-Path-Payload
Enhanced Remote Failure Indication-Path-Server
Error in Startup Configuration
Rear Panel Ethernet Link Removed
Excess Collisions on the LAN
Exercise Request on Ring Failed
Exercise Request on Ring
Exercise Request on Span Failed
Exercise Request on Span
Failure Detected External To The NE
Extra Traffic Preempted
2
ONS_SONET_TL1_Command_Guide_R8.5.1_--_Conditions
FAILTOSW
FAILTOSW-PATH
FAILTOSWR
FAILTOSWS
FAN
FANDEGRADE
FE-AIS
FE-DS1-MULTLOS
FE-DS1-NSA
FE-DS1-SA
FE-DS1-SNGLLOS
FE-DS3-NSA
FE-DS3-SA
FE-EQPT-NSA
FE-EXERCISING-RING
FE-EXERCISING-SPAN
FE-FRCDWKSWPR-RING
FE-FRCDWKSWPR-SPAN
FE-IDLE
FE-LOCKOUTOFPR-SPAN
FE-LOF
FE-LOS
FE-MANWKSWPR-RING
FE-MANWKSWPR-SPAN
FEC-MISM
FEPRLF
FORCED-REQ
FORCED-REQ-RING
FORCED-REQ-SPAN
FRCDSWTOINT
FRCDSWTOPRI
FRCDSWTOSEC
FRCDSWTOTHIRD
FRNGSYNC
FSTSYNC
FULLPASSTHR-BI
GCC-EOC
GE-OOSYNC
HI-LASERBIAS
HI-RXPOWER
HI-TXPOWER
HITEMP
HLDOVRSYNC
I-HITEMP
Table 27-1: Conditions
Failure To Switch To Protection
Failure To Switch To Protection-Path
Failure To Switch To Protection-Ring
Failure To Switch To Protection-Span
Fan Failure
Partial Fan Failure
Far End AIS
Far End Multiple DS1 LOS Detected On DS3
Far End DS1 Equipment Failure-Non-Service-Affecting
Far End DS1 Equipment Failure-Service-Affecting
Far End Single DS1 Loss of Signal (LOS)
Far End DS3 Equipment Failure-Non-Service-Affecting
Far End DS3 Equipment Failure-Service-Affecting
Far End Common Equipment Failure-Non-Service-Affecting
Far End Exercising Ring
Far End Exercising Span
Far End Working Facility Forced To Switch To Protection-Ring
Far End Working Facility Forced To Switch To Protection-Span
Far End Idle
Far End Lockout Of Protection-Span
Far End LOF
Far End LOS
Far End Manual Switch Of Working Facility To Protection-Ring
Far End Manual Switch Of Working Facility To Protection-Span
FEC Mismatch
Far End Protection Line Failure
Forced Switch Request
Forced Switch Request On Ring
Forced Switch Request On Span
Forced Switch To Internal Clock
Forced Switch To Primary Reference
Forced Switch To Second Reference
Forced Switch To Third Reference
Free Running Synchronization Mode
Fast Start Synchronization Mode
Bidirectional Full Pass Through Is Active
GCC Termination Failure
Gigabit Ethernet Out of Synchronization
Equipment High Laser Bias
Equipment High Receive (Rx) Power
Equipment High Transmit (Tx) Power
High Temperature
Holdover Synchronization Mode
Industrial High Temperature
3
ONS_SONET_TL1_Command_Guide_R8.5.1_--_Conditions
IMPROPRMVL
Improper Removal
Out Of Frame Detected by Generic Framing Procedure (GFP)
INC-GFP-OUTOFFRAME
Receiver
INC-GFP-SIGLOSS
Client Signal Loss Frames Detected by GFP Receiver
INC-ISD
DS3 Idle Condition
INC-SIGLOSS
Incoming Signal Loss on Fibre Channel Interface
INC-SYNCLOSS
Incoming Synchronization Loss on Fibre Channel Interface
INC_GFP_SYNCLOSS
Client Synchronization Loss Frames Detected by GFP Receiver
INHSWPR
Inhibit Switch To Protect Request On Equipment
INHSWWKG
Inhibit Switch To Working Request On Equipment
INTRUSION-PSWD
Security Intrusion Attempt Detected-See Audit Log
INVMACADR
Invalid MAC Address
IOSCFGCOPY
IOS Configuration Copy In Progress
KB-PASSTHR
K Byte Pass Through Is Active
KBYTE-APS-CHANNEL-FAILURE K Byte Channel Failure
LAN-POL-REV
LAN Connection Polarity Reversed
LASEREOL
Laser Approaching End of Life
LKOUTPR-S
Lockout Of Protection-Span
LMP-HELLODOWN
LMP Hello FSM to Control Channel Down
LMP-NDFAIL
LMP Neighbor Discovery has failed
LO-RXPOWER
Equipment Low Rx Power
LO-TXPOWER
Equipment Low Tx Power
LOA
Loss of Alignment
LOC
Loss of Channel
LOCKOUT-REQ
Lockout Switch Request On Facility or Equipment
LOCKOUT-REQ-RING
Lockout Switch Request On Ring
LOF
Loss Of Frame
LOM
Loss of Multiframe
LOP-P
Loss Of Pointer-Path
LOP-V
Loss Of Pointer-VT
LOS
Loss Of Signal
LPBKCRS
Cross-connect Loopback
DS1 Loopback Due To Far End Alarm and Control (FEAC)
LPBKDS1FEAC
Command
LPBKDS1FEAC-CMD
DS1 Loopback Command Sent To Far End
LPBKDS3FEAC
DS3 Loopback Due To FEAC Command
LPBKDS3FEAC-CMD
DS3 Loopback Command Sent To Far End
LPBKFACILITY
Facility Loopback
LPBKTERMINAL
Terminal Loopback
LWBATVG
Low Volt
MAN-REQ
Manual Switch Request
MANRESET
Manual System Reset
MANSWTOINT
Manual Switch To Internal Clock
MANSWTOPRI
Manual Switch To Primary Reference
Table 27-1: Conditions
4
ONS_SONET_TL1_Command_Guide_R8.5.1_--_Conditions
MANSWTOSEC
MANSWTOTHIRD
MANUAL-REQ-RING
MANUAL-REQ-SPAN
MEA
MEM-GONE
MEM-LOW
MFGMEM
NO-CONFIG
NTWTPINC
OCHNC-ACTIV-FAIL
OCHNC-DEACTIV-FAIL
OCHNC-FAIL
OCHNC-INC
ODUK-AIS-PM
ODUK-BDI-PM
ODUK-LCK-PM
ODUK-OCI-PM
ODUK-SD-PM
ODUK-SF-PM
ODUK-TIM-PM
OOU-TPT
OPTNTWMIS
OTUK-AIS
OTUK-BDI
OTUK-LOF
OTUK-SD
OTUK-SF
OTUK-TIM
OUT-OF-SYNC
PDI-P
PEER-NORESPONSE
PLM-P
PLM-V
PORT-CODE-MISM
PORT-COMM-FAIL
PORT-MISMATCH
PORT-MISSING
PRC-DUPID
PROTNA
PTIM
PWR-REDUN
RAI
RCVR-MISS
Table 27-1: Conditions
Manual Switch To Second Reference
Manual Switch To Third Reference
Manual Switch Request On Ring
Manual Switch Request On Span
Mismatch Of Equipment And Attributes
Free Memory On Card Near Zero
Free Memory On Card Very Low
Manufacturing Data Memory (EEPROM Failure)
No Startup Config
Network Topology Incomplete
Optical Channel Activation Failure
Optical Channel Deactivation Failure
Optical Channel Connection Failure
Optical Channel Incomplete
ODUk: Alarm Indication Signal
ODUk: PM Backward Defect Indication
ODUk: Locked Defect-PM
ODUk: Open Connection Indication
ODUk: Signal Degrade
ODUk: Signal Failure
ODUk: Trail Trace Identifier Mismatch
Out of Use-Transport Failure
Optical Network Type Mismatch
OTUk: Alarm Indication Signal
OTUk: Backward Defect Indication
OTUk: Loss Of Frame
OTUk: Signal Degrade
OTUk: Signal Failure
OTUk: Trail Trace Identifier Mismatch
8B10B Out of Sync
Payload Defect Indication-Path
Peer Card Not Responding
Payload Label Mismatch-Path
Signal Label Mismatch Failure-Payload Label Mismatch-VT
Pluggable Port security code mismatch
Module Communication Failure
Pluggable Port rate mismatch
Pluggable Port missing
Duplicate Node ID
Protection Unit Not Available
Payload Type Identifier Mismatch
Redundant Power Capability Lost
Remote Alarm Indication
Facility Termination Equipment-Receiver Missing
5
ONS_SONET_TL1_Command_Guide_R8.5.1_--_Conditions
RFI
RFI-L
RFI-P
RFI-V
RING-ID-MIS
RING-MISMATCH
RING-SW-EAST
RING-SW-WEST
RSVP-HELLODOWN
RUNCFG-SAVENEED
SD
SD-L
SD-P
SF
SF-L
SF-P
SFTWDOWN
SNTP-HOST
SPAN-SW-EAST
SPAN-SW-WEST
SQM
SQUELCH
SQUELCHED
SSM-DUS
SSM-FAIL
SSM-LNC
SSM-OFF
SSM-PRC
SSM-PRS
SSM-RES
SSM-SDH-TN
SSM-SETS
SSM-SMC
SSM-ST2
SSM-ST3
SSM-ST3E
SSM-ST4
SSM-STU
SSM-TNC
SWMTXMOD
SWTOPRI
SWTOSEC
SWTOTHIRD
SYNC-FREQ
Table 27-1: Conditions
Remote Failure Indication
Remote Failure Indication-Line
One-Bit Remote Failure Indication-Path
Remote Failure Indication-VT
Ring ID Mismatch
Far End of Fiber Is Provisioned With Different Ring ID
Ring Switch Is Active on the East Side
Ring Switch Is Active on the West Side
RSVP Hello FSM to Neighbor Down
Need to Save Running Configuration
Signal Degrade
Bit Error Rate (BER) Threshold Exceeded For Signal Degrade-Line
BER Threshold Exceeded For Signal Degrade-Path
Signal Failure
BER Threshold Exceeded For Signal Failure-Line
BER Threshold Exceeded For Signal Failure-Path
Software Download In Progress
Simple Network Time Protocol (SNTP) Host Failure
Span Switch Is Active On The East Side
Span Switch Is Active On The West Side
Sequence Mismatch
Ring Is Squelching Traffic
Equipment Squelched
Do Not Use For Synchronization
Failed To Receive Synchronization Status Message
G812-Local Node Clock Traceable
Synchronization Status Messages Are Disabled On This Interface
G811-Primary Reference Clock Traceable
Stratum 1 Primary Reference Source Traceable
Reserved For Network Synchronization Use
G812-Transit Node Clock Traceable
G813-Synchronous Equipment Timing Source Traceable
SONET Minimum Clock Traceable
Stratum 2 Traceable
Stratum 3 Traceable
Stratum 3E Traceable
Stratum 4 Traceable
Synchronized-Traceability Unknown
Transit Node Clock Traceable
Switching Matrix Module Failure
Switch To Primary Reference
Switch To Second Reference
Switch To Third Reference
Synchronization Reference Frequency Out Of Bounds
6
ONS_SONET_TL1_Command_Guide_R8.5.1_--_Conditions
SYNCPRI
SYNCSEC
SYNCTHIRD
SYSBOOT
TIM
TIM-MON
TIM-P
TPTFAIL
TRMT
TRMT-MISS
TUNDERRUN
TX-AIS
TX-RAI
UNC-WORD
UNEQ-P
UNEQ-V
VCG-DEG
VCG-DOWN
WKSWPR
WTR
WVL-MISMATCH
Table 27-1: Conditions
Primary Synchronization Reference Failure
Secondary Synchronization Reference Failure
Third Synchronization Reference Failure
System Reboot
TIM Section-Trace Identifier Mismatch Failure
TIM Section Monitor-Trace Identifier Mismatch Failure
STS Path Trace Identifier Mismatch
Transport layer failure
Transmit Failure
Facility Termination Equipment-Transmitter Missing
Ethernet Transmit First In First Out Underrun
Alarm Indication Signal in Tx
Remote Alarm Indication in Tx
Forward Error Correction (FEC) Uncorrected Word
Unequipped-Path
Signal Label Mismatch Failure-Unequipped VT
Virtual Concatenation (VCAT) Group Degraded
VCAT Group Down
Switched To Protection
Wait To Restore
Equipment Wavelength Mismatch
7
Download