ONS_SONET_TL1_Command_Guide_R8.5.1_--_Conditions Note: The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration. This chapter describes the conditions for TL1 commands and autonomous messages for the Cisco ONS 15454, Cisco ONS 15310-CL, Cisco ONS 15310-MA, and Cisco ONS 15600. Conditions include any problem detected on an ONS 15454, ONS 15310-CL, ONS 15310-MA, or ONS 15600 shelf. They can include standing or transient notifications. A snapshot of all currently raised standing conditions on the network, node, or card can be retrieved in the Cisco Transport Controller (CTC) Conditions window or using the RTRV-COND commands. (In addition, some but not all cleared conditions are found in the CTC History tab.) Table 27-1: Conditions Condition AIS AIS-L AIS-P AIS-V ALS APC-DISABLED APC-FAIL APSB APSC-IMP APSCDFLTK APSCINCON APSCM APSCNMIS APSIMP APSMM AS-CMD AS-MT AU-LOF AUD-LOG-LOSS AUD-LOG-LOW AUTOLSROFF AUTORESET AUTOSW-AIS AUTOSW-LOP AUTOSW-PDI AUTOSW-SDBER AUTOSW-SFBER AUTOSW-UNEQ BAT-FAIL Table 27-1: Conditions Description Alarm Indication Signal Alarm Indication Signal-Line Alarm Indication Signal-Path Alarm Indication Signal-VT Automatic Laser Shutdown Automatic Power Control Disabled Automatic Power Control Failure Byte Failure Improper Automatic Protection Switch (APS) Code Default K Byte Inconsistent APS Code Protection Switching Channel Match Failure Node ID Mismatch APS Invalid Mode Automatic Protection Switch Mode Mismatch Alarms Suppressed By User Command Alarms Suppressed For Maintenance Loss of Frame (LOF)-Administration Unit-Loss of Multiframe Audit Log 100 Percent Full-Oldest records will be lost Audit Log 80 Percent Full Automatic Laser Shutoff Due To High Temperature Automatic System Reset Automatic Path Protection Switch Caused By AIS Automatic Path Protection Switch Caused By LOP Automatic Path Protection Switch Caused By PDI Automatic Path Protection Switch Caused By SDBER Automatic Path Protection Switch Caused By SFBER Automatic Path Protection Switch Caused By UNEQ Battery Failure 1 ONS_SONET_TL1_Command_Guide_R8.5.1_--_Conditions BAT-HGH-VLT BAT-LOW-VLT BKUPMEMP BLSROSYNC CARLOSS CKTDOWN CLDRESTART COMIOXC COMM-FAIL CONTBUS-A-18 CONTBUS-B-18 CONTBUS_A CONTBUS_B CTNEQPT-MISMATCH CTNEQPT-PBPROT CTNEQPT-PBWORK DATAFLT DBOSYNC DS3-MISM DSP-COMM-FAIL DSP-FAIL DUP-IPADDR DUP-NODENAME E-W-MISMATCH EHIBATVG ELWBATVG EOC EOC-L EQPT EQPT-MISS ERFI-P-CONN ERFI-P-PAYLD ERFI-P-SRVR ERROR-CONFIG ETH-LINKLOSS EXCCOL EXERCISE-RING-FAIL EXERCISE-RING-REQ EXERCISE-SPAN-FAIL EXERCISE-SPAN-REQ EXT EXTRA-TRAF-PREEMPT Table 27-1: Conditions High Volt Low Volt Primary Nonvolatile Backup Memory Failure BLSR Out Of Sync Carrier Loss On The LAN Signaling Unable to Set Up Circuit Cold Restart Input/Output (IO) Slot To Cross-connect (XCON) Communication Failure Plug-in Module Communication Failure TCC A To DCC A Processor Communication Failure TCC B To DCC B Processor Communication Failure Controller A To Shelf Slot Communication Failure Controller B To Shelf Slot Communication Failure Connection Equipment Mismatch Interconnection Equipment Failure-Protect XC Payload Bus Interconnection Equipment Failure-Working XC Payload Bus Software Fault-Data Integrity Fault Standby Database Out of Synchronization DS3 Frame Format Mismatch DSP Communication Failure DSP Failure IP address already in use within the same data communications channel (DCC) area Node name already in use within the same DCC area Both Ends Of Fiber Provisioned As East Or Both As West Extreme High Voltage Extreme Low Voltage Section DCC (SDCC) Termination Failure Line DCC (LDCC) Termination Failure Equipment Failure Replaceable Equipment/Unit is Missing Enhanced Remote Failure Indication-Path-Connectivity Enhanced Remote Failure Indication-Path-Payload Enhanced Remote Failure Indication-Path-Server Error in Startup Configuration Rear Panel Ethernet Link Removed Excess Collisions on the LAN Exercise Request on Ring Failed Exercise Request on Ring Exercise Request on Span Failed Exercise Request on Span Failure Detected External To The NE Extra Traffic Preempted 2 ONS_SONET_TL1_Command_Guide_R8.5.1_--_Conditions FAILTOSW FAILTOSW-PATH FAILTOSWR FAILTOSWS FAN FANDEGRADE FE-AIS FE-DS1-MULTLOS FE-DS1-NSA FE-DS1-SA FE-DS1-SNGLLOS FE-DS3-NSA FE-DS3-SA FE-EQPT-NSA FE-EXERCISING-RING FE-EXERCISING-SPAN FE-FRCDWKSWPR-RING FE-FRCDWKSWPR-SPAN FE-IDLE FE-LOCKOUTOFPR-SPAN FE-LOF FE-LOS FE-MANWKSWPR-RING FE-MANWKSWPR-SPAN FEC-MISM FEPRLF FORCED-REQ FORCED-REQ-RING FORCED-REQ-SPAN FRCDSWTOINT FRCDSWTOPRI FRCDSWTOSEC FRCDSWTOTHIRD FRNGSYNC FSTSYNC FULLPASSTHR-BI GCC-EOC GE-OOSYNC HI-LASERBIAS HI-RXPOWER HI-TXPOWER HITEMP HLDOVRSYNC I-HITEMP Table 27-1: Conditions Failure To Switch To Protection Failure To Switch To Protection-Path Failure To Switch To Protection-Ring Failure To Switch To Protection-Span Fan Failure Partial Fan Failure Far End AIS Far End Multiple DS1 LOS Detected On DS3 Far End DS1 Equipment Failure-Non-Service-Affecting Far End DS1 Equipment Failure-Service-Affecting Far End Single DS1 Loss of Signal (LOS) Far End DS3 Equipment Failure-Non-Service-Affecting Far End DS3 Equipment Failure-Service-Affecting Far End Common Equipment Failure-Non-Service-Affecting Far End Exercising Ring Far End Exercising Span Far End Working Facility Forced To Switch To Protection-Ring Far End Working Facility Forced To Switch To Protection-Span Far End Idle Far End Lockout Of Protection-Span Far End LOF Far End LOS Far End Manual Switch Of Working Facility To Protection-Ring Far End Manual Switch Of Working Facility To Protection-Span FEC Mismatch Far End Protection Line Failure Forced Switch Request Forced Switch Request On Ring Forced Switch Request On Span Forced Switch To Internal Clock Forced Switch To Primary Reference Forced Switch To Second Reference Forced Switch To Third Reference Free Running Synchronization Mode Fast Start Synchronization Mode Bidirectional Full Pass Through Is Active GCC Termination Failure Gigabit Ethernet Out of Synchronization Equipment High Laser Bias Equipment High Receive (Rx) Power Equipment High Transmit (Tx) Power High Temperature Holdover Synchronization Mode Industrial High Temperature 3 ONS_SONET_TL1_Command_Guide_R8.5.1_--_Conditions IMPROPRMVL Improper Removal Out Of Frame Detected by Generic Framing Procedure (GFP) INC-GFP-OUTOFFRAME Receiver INC-GFP-SIGLOSS Client Signal Loss Frames Detected by GFP Receiver INC-ISD DS3 Idle Condition INC-SIGLOSS Incoming Signal Loss on Fibre Channel Interface INC-SYNCLOSS Incoming Synchronization Loss on Fibre Channel Interface INC_GFP_SYNCLOSS Client Synchronization Loss Frames Detected by GFP Receiver INHSWPR Inhibit Switch To Protect Request On Equipment INHSWWKG Inhibit Switch To Working Request On Equipment INTRUSION-PSWD Security Intrusion Attempt Detected-See Audit Log INVMACADR Invalid MAC Address IOSCFGCOPY IOS Configuration Copy In Progress KB-PASSTHR K Byte Pass Through Is Active KBYTE-APS-CHANNEL-FAILURE K Byte Channel Failure LAN-POL-REV LAN Connection Polarity Reversed LASEREOL Laser Approaching End of Life LKOUTPR-S Lockout Of Protection-Span LMP-HELLODOWN LMP Hello FSM to Control Channel Down LMP-NDFAIL LMP Neighbor Discovery has failed LO-RXPOWER Equipment Low Rx Power LO-TXPOWER Equipment Low Tx Power LOA Loss of Alignment LOC Loss of Channel LOCKOUT-REQ Lockout Switch Request On Facility or Equipment LOCKOUT-REQ-RING Lockout Switch Request On Ring LOF Loss Of Frame LOM Loss of Multiframe LOP-P Loss Of Pointer-Path LOP-V Loss Of Pointer-VT LOS Loss Of Signal LPBKCRS Cross-connect Loopback DS1 Loopback Due To Far End Alarm and Control (FEAC) LPBKDS1FEAC Command LPBKDS1FEAC-CMD DS1 Loopback Command Sent To Far End LPBKDS3FEAC DS3 Loopback Due To FEAC Command LPBKDS3FEAC-CMD DS3 Loopback Command Sent To Far End LPBKFACILITY Facility Loopback LPBKTERMINAL Terminal Loopback LWBATVG Low Volt MAN-REQ Manual Switch Request MANRESET Manual System Reset MANSWTOINT Manual Switch To Internal Clock MANSWTOPRI Manual Switch To Primary Reference Table 27-1: Conditions 4 ONS_SONET_TL1_Command_Guide_R8.5.1_--_Conditions MANSWTOSEC MANSWTOTHIRD MANUAL-REQ-RING MANUAL-REQ-SPAN MEA MEM-GONE MEM-LOW MFGMEM NO-CONFIG NTWTPINC OCHNC-ACTIV-FAIL OCHNC-DEACTIV-FAIL OCHNC-FAIL OCHNC-INC ODUK-AIS-PM ODUK-BDI-PM ODUK-LCK-PM ODUK-OCI-PM ODUK-SD-PM ODUK-SF-PM ODUK-TIM-PM OOU-TPT OPTNTWMIS OTUK-AIS OTUK-BDI OTUK-LOF OTUK-SD OTUK-SF OTUK-TIM OUT-OF-SYNC PDI-P PEER-NORESPONSE PLM-P PLM-V PORT-CODE-MISM PORT-COMM-FAIL PORT-MISMATCH PORT-MISSING PRC-DUPID PROTNA PTIM PWR-REDUN RAI RCVR-MISS Table 27-1: Conditions Manual Switch To Second Reference Manual Switch To Third Reference Manual Switch Request On Ring Manual Switch Request On Span Mismatch Of Equipment And Attributes Free Memory On Card Near Zero Free Memory On Card Very Low Manufacturing Data Memory (EEPROM Failure) No Startup Config Network Topology Incomplete Optical Channel Activation Failure Optical Channel Deactivation Failure Optical Channel Connection Failure Optical Channel Incomplete ODUk: Alarm Indication Signal ODUk: PM Backward Defect Indication ODUk: Locked Defect-PM ODUk: Open Connection Indication ODUk: Signal Degrade ODUk: Signal Failure ODUk: Trail Trace Identifier Mismatch Out of Use-Transport Failure Optical Network Type Mismatch OTUk: Alarm Indication Signal OTUk: Backward Defect Indication OTUk: Loss Of Frame OTUk: Signal Degrade OTUk: Signal Failure OTUk: Trail Trace Identifier Mismatch 8B10B Out of Sync Payload Defect Indication-Path Peer Card Not Responding Payload Label Mismatch-Path Signal Label Mismatch Failure-Payload Label Mismatch-VT Pluggable Port security code mismatch Module Communication Failure Pluggable Port rate mismatch Pluggable Port missing Duplicate Node ID Protection Unit Not Available Payload Type Identifier Mismatch Redundant Power Capability Lost Remote Alarm Indication Facility Termination Equipment-Receiver Missing 5 ONS_SONET_TL1_Command_Guide_R8.5.1_--_Conditions RFI RFI-L RFI-P RFI-V RING-ID-MIS RING-MISMATCH RING-SW-EAST RING-SW-WEST RSVP-HELLODOWN RUNCFG-SAVENEED SD SD-L SD-P SF SF-L SF-P SFTWDOWN SNTP-HOST SPAN-SW-EAST SPAN-SW-WEST SQM SQUELCH SQUELCHED SSM-DUS SSM-FAIL SSM-LNC SSM-OFF SSM-PRC SSM-PRS SSM-RES SSM-SDH-TN SSM-SETS SSM-SMC SSM-ST2 SSM-ST3 SSM-ST3E SSM-ST4 SSM-STU SSM-TNC SWMTXMOD SWTOPRI SWTOSEC SWTOTHIRD SYNC-FREQ Table 27-1: Conditions Remote Failure Indication Remote Failure Indication-Line One-Bit Remote Failure Indication-Path Remote Failure Indication-VT Ring ID Mismatch Far End of Fiber Is Provisioned With Different Ring ID Ring Switch Is Active on the East Side Ring Switch Is Active on the West Side RSVP Hello FSM to Neighbor Down Need to Save Running Configuration Signal Degrade Bit Error Rate (BER) Threshold Exceeded For Signal Degrade-Line BER Threshold Exceeded For Signal Degrade-Path Signal Failure BER Threshold Exceeded For Signal Failure-Line BER Threshold Exceeded For Signal Failure-Path Software Download In Progress Simple Network Time Protocol (SNTP) Host Failure Span Switch Is Active On The East Side Span Switch Is Active On The West Side Sequence Mismatch Ring Is Squelching Traffic Equipment Squelched Do Not Use For Synchronization Failed To Receive Synchronization Status Message G812-Local Node Clock Traceable Synchronization Status Messages Are Disabled On This Interface G811-Primary Reference Clock Traceable Stratum 1 Primary Reference Source Traceable Reserved For Network Synchronization Use G812-Transit Node Clock Traceable G813-Synchronous Equipment Timing Source Traceable SONET Minimum Clock Traceable Stratum 2 Traceable Stratum 3 Traceable Stratum 3E Traceable Stratum 4 Traceable Synchronized-Traceability Unknown Transit Node Clock Traceable Switching Matrix Module Failure Switch To Primary Reference Switch To Second Reference Switch To Third Reference Synchronization Reference Frequency Out Of Bounds 6 ONS_SONET_TL1_Command_Guide_R8.5.1_--_Conditions SYNCPRI SYNCSEC SYNCTHIRD SYSBOOT TIM TIM-MON TIM-P TPTFAIL TRMT TRMT-MISS TUNDERRUN TX-AIS TX-RAI UNC-WORD UNEQ-P UNEQ-V VCG-DEG VCG-DOWN WKSWPR WTR WVL-MISMATCH Table 27-1: Conditions Primary Synchronization Reference Failure Secondary Synchronization Reference Failure Third Synchronization Reference Failure System Reboot TIM Section-Trace Identifier Mismatch Failure TIM Section Monitor-Trace Identifier Mismatch Failure STS Path Trace Identifier Mismatch Transport layer failure Transmit Failure Facility Termination Equipment-Transmitter Missing Ethernet Transmit First In First Out Underrun Alarm Indication Signal in Tx Remote Alarm Indication in Tx Forward Error Correction (FEC) Uncorrected Word Unequipped-Path Signal Label Mismatch Failure-Unequipped VT Virtual Concatenation (VCAT) Group Degraded VCAT Group Down Switched To Protection Wait To Restore Equipment Wavelength Mismatch 7