www.SquareD.com

advertisement
Enclosures
Class 610
www.SquareD.com
For the most up-to-date information
• Circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment except as
footnoted.
• The short circuit rating of an enclosed circuit breaker is equal to the rating of the circuit breaker installed, except
as footnoted.
• Circuit breakers are ordered and shipped separately for field-installation—see pages 6-20 through 6-24.
• For enclosure accessories and dimensions refer to page 6-52.
Number
of Poles
Enclosure
Catalog Number
15–100
1, 2, 3
100–200
2
...
100–225
2, 3
15–150
2, 3
150–250
2, 3
LAL, LHL, Q4L,
KAL, KHL
125–400
2, 3
MEL
450–800
3
MAL, MHLd, MXLd,
LAL, LHL, Q4L
125–1000
2, 3
FA100S
QBL, QDL, QGL, QJL
HDL,HGL,HJL,HLL
JDL,JGL,JJL,JLL
FA100F
Catalog Number
Prefix
FA100S
FAL, FHL, FCL
15–100
1, 2, 3
HDL,HGL,HJL,HLL
15–150
2, 3
150–250
2, 3
$ 126.
FA100RB
Price
$ 333.
Q22200NSbe
117.k
Q22200NRBbe
253.k
Q23225NFbe
145.k
Q23225NSbe
145.k
Q23225NRBbe
278.k
J250F
190.
J250S
190.
J250R
560.
LA400F
237.
LA400S
...
ME1000Sc
422.
MA1000S
Enclosure
Catalog Number
237.
4330.
422.
LA400R
1103.
ME1000Rc
4389.
MA1000R
1439.
NEMA 12/3R, 12K (Hubs—See page 3-9)
NEMA 4, 4X, 5, 3, 3R
Stainless Steel
(Hubs—See page 3-9)
Number
of Poles
NEMA 3Ra
Enclosure
Catalog Number
Price
...
MA1000F
Ampere
Rating
JDL,JGL,JJL,JLL
$126.
...
Circuit Breaker
FA100RB
NEMA 1 Surface
Enclosure
Catalog Number
Price
With Knockouts
(NEMA 12K)
Without Knockoutsf
(NEMA 12/3R, 5)
Price
Catalog
Number
Price
$ 954.
FA100A
$234.
J250DS
2270.
...
...
J250AWK
388.
585.
FA100DS
Catalog
Number
FA100AWK
Price
$ 223.
KAL, KILh, KCL, KHL
110–250
2, 3
IK250DS
3492.
...
...
IK250AWK
LAL, LHL, Q4L
125–400
2, 3
LA400DS
3782.
...
...
LA400AWK
602.
LELg, LXL, LXIL
100–600
3
...
...
...
LX600AWK
2485.
LCL, LIL
300–600
2, 3
...
...
...
...
LX600AWK
2485.
MAL, MHLd, MXLd
300–1000
2, 3
MA1000DS
6750.
...
...
MA1000AWK
1203.
NAL, NCL, NXL
600–1200
2, 3
...
...
...
...
NA1200AWKij
1749.
...
NEMA 7 k
Cast Aluminum
Circuit Breaker
Catalog Number
Prefix
Ampere
Rating
Number
of Poles
15–60
1, 2, 3
15–100
1, 2, 3
70–225
2, 3
FALn
KALn
Enclosure
Catalog Number
NEMA 9 l
Cast Aluminum
Price
Enclosure
Catalog Number
FA060Xm
$1080.
FA060Ye
FA100Xm
1337.
FA100Ye
KA225Xoem
2722.
KA225Yoe
Price
$ 818.
926.
1889.
FA100DS
Enclosures for Walking Beam Mechanical Interlock Circuit Breakers (UL Listed)p
Circuit Breaker
FA100X
NEMA 1 Surfaceq
Catalog Number
Prefix...Suffix
Ampere
Rating
Number
of Poles
FAL...WB, FHL...WB, KAL...WB
15–250
2, 3
Enclosure
Catalog Number
KA250SWB
NEMA 3Rqr
Price
$693.
Enclosure
Catalog Number
KA250RWB
Price
$1218.
a Enclosures with NRB or RB suffix have provisions for 3⁄4" through 21⁄2" bolt-on hubs in top endwall. Enclosures with R suffix have blank endwalls and require
field cut opening. For details and hub catalog numbers see page 3-9.
b Factory-installed groundable neutral assembly includes (2) ground lugs and (2) neutral lugs.
c MEL100% rated breaker-short circuit rating is 50,000 AIR at 480 Vac maximum. For other voltages, see circuit breaker ratings.
d MHL, MXL short circuit rating is 50,000 AIR at 480 Vac maximum.
e Not CSA Certified.
f Suitable for rainproof NEMA 3R application by removing drain screw from bottom endwall.
g LEL 100% rated circuit breaker except for 600 A sensor.
h Short circuit rating is 100,000 AIR at 480 Vac maximum.
i Short Circuit Ratings: NAL, 240 Vac—100,000, 480 Vac—50,000, 600 Vac—25,000
NCL, 240 Vac—125,000, 480 Vac—100,000, 600 Vac—65,000
NXL, 240 Vac—65,000, 480 Vac—50,000, 600 Vac—42,000
j Does not have outside operator, not CSA Certified.
k NEMA 7—Indoor Hazardous Locations—Division 1 and 2, Class I, Groups C and D; Class II, Groups E, F and G; Class III.
l NEMA 9—Indoor Hazardous Locations—Division 1 and 2, Class II, Groups E, F and G; Class III.
m Suitable for rainproof applications—includes PKDB1 breather and drain kit.
n Use 75°C Copper conductors only.
o Not UL Listed due to wire bending space requirements.
p Catalog number in table is enclosure only. For complete installation, the following must be ordered separately:
WB Circuit Breakers (qty. 2, page 6-36), Walking Beam Assembly (page 6-36), Mounting Pan (page 6-36),
Neutral (page 6-52) and Service Ground Kit (page 6-52).
q For applications above 200 A requiring a neutral, use copper wire only.
r Enclosure has blank top endwall.
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6-52
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6-52
FA100Y
© 2005 Schneider Electric
All Rights Reserved
9/16/05
9/16/05
DE1
kDE2A
Discount
Schedule
6-51
CIRCUIT BREAKERS
FAL, FHL, FCL
NEMA 1 Flush
Ampere
Rating
6
Circuit Breaker
Catalog Number
Prefix
Download