Enclosures Class 610 www.SquareD.com For the most up-to-date information • Circuit breaker enclosures are UL Listed, CSA Certified and are suitable for use as service equipment except as footnoted. • The short circuit rating of an enclosed circuit breaker is equal to the rating of the circuit breaker installed, except as footnoted. • Circuit breakers are ordered and shipped separately for field-installation—see pages 6-20 through 6-24. • For enclosure accessories and dimensions refer to page 6-52. Number of Poles Enclosure Catalog Number 15–100 1, 2, 3 100–200 2 ... 100–225 2, 3 15–150 2, 3 150–250 2, 3 LAL, LHL, Q4L, KAL, KHL 125–400 2, 3 MEL 450–800 3 MAL, MHLd, MXLd, LAL, LHL, Q4L 125–1000 2, 3 FA100S QBL, QDL, QGL, QJL HDL,HGL,HJL,HLL JDL,JGL,JJL,JLL FA100F Catalog Number Prefix FA100S FAL, FHL, FCL 15–100 1, 2, 3 HDL,HGL,HJL,HLL 15–150 2, 3 150–250 2, 3 $ 126. FA100RB Price $ 333. Q22200NSbe 117.k Q22200NRBbe 253.k Q23225NFbe 145.k Q23225NSbe 145.k Q23225NRBbe 278.k J250F 190. J250S 190. J250R 560. LA400F 237. LA400S ... ME1000Sc 422. MA1000S Enclosure Catalog Number 237. 4330. 422. LA400R 1103. ME1000Rc 4389. MA1000R 1439. NEMA 12/3R, 12K (Hubs—See page 3-9) NEMA 4, 4X, 5, 3, 3R Stainless Steel (Hubs—See page 3-9) Number of Poles NEMA 3Ra Enclosure Catalog Number Price ... MA1000F Ampere Rating JDL,JGL,JJL,JLL $126. ... Circuit Breaker FA100RB NEMA 1 Surface Enclosure Catalog Number Price With Knockouts (NEMA 12K) Without Knockoutsf (NEMA 12/3R, 5) Price Catalog Number Price $ 954. FA100A $234. J250DS 2270. ... ... J250AWK 388. 585. FA100DS Catalog Number FA100AWK Price $ 223. KAL, KILh, KCL, KHL 110–250 2, 3 IK250DS 3492. ... ... IK250AWK LAL, LHL, Q4L 125–400 2, 3 LA400DS 3782. ... ... LA400AWK 602. LELg, LXL, LXIL 100–600 3 ... ... ... LX600AWK 2485. LCL, LIL 300–600 2, 3 ... ... ... ... LX600AWK 2485. MAL, MHLd, MXLd 300–1000 2, 3 MA1000DS 6750. ... ... MA1000AWK 1203. NAL, NCL, NXL 600–1200 2, 3 ... ... ... ... NA1200AWKij 1749. ... NEMA 7 k Cast Aluminum Circuit Breaker Catalog Number Prefix Ampere Rating Number of Poles 15–60 1, 2, 3 15–100 1, 2, 3 70–225 2, 3 FALn KALn Enclosure Catalog Number NEMA 9 l Cast Aluminum Price Enclosure Catalog Number FA060Xm $1080. FA060Ye FA100Xm 1337. FA100Ye KA225Xoem 2722. KA225Yoe Price $ 818. 926. 1889. FA100DS Enclosures for Walking Beam Mechanical Interlock Circuit Breakers (UL Listed)p Circuit Breaker FA100X NEMA 1 Surfaceq Catalog Number Prefix...Suffix Ampere Rating Number of Poles FAL...WB, FHL...WB, KAL...WB 15–250 2, 3 Enclosure Catalog Number KA250SWB NEMA 3Rqr Price $693. Enclosure Catalog Number KA250RWB Price $1218. a Enclosures with NRB or RB suffix have provisions for 3⁄4" through 21⁄2" bolt-on hubs in top endwall. Enclosures with R suffix have blank endwalls and require field cut opening. For details and hub catalog numbers see page 3-9. b Factory-installed groundable neutral assembly includes (2) ground lugs and (2) neutral lugs. c MEL100% rated breaker-short circuit rating is 50,000 AIR at 480 Vac maximum. For other voltages, see circuit breaker ratings. d MHL, MXL short circuit rating is 50,000 AIR at 480 Vac maximum. e Not CSA Certified. f Suitable for rainproof NEMA 3R application by removing drain screw from bottom endwall. g LEL 100% rated circuit breaker except for 600 A sensor. h Short circuit rating is 100,000 AIR at 480 Vac maximum. i Short Circuit Ratings: NAL, 240 Vac—100,000, 480 Vac—50,000, 600 Vac—25,000 NCL, 240 Vac—125,000, 480 Vac—100,000, 600 Vac—65,000 NXL, 240 Vac—65,000, 480 Vac—50,000, 600 Vac—42,000 j Does not have outside operator, not CSA Certified. k NEMA 7—Indoor Hazardous Locations—Division 1 and 2, Class I, Groups C and D; Class II, Groups E, F and G; Class III. l NEMA 9—Indoor Hazardous Locations—Division 1 and 2, Class II, Groups E, F and G; Class III. m Suitable for rainproof applications—includes PKDB1 breather and drain kit. n Use 75°C Copper conductors only. o Not UL Listed due to wire bending space requirements. p Catalog number in table is enclosure only. For complete installation, the following must be ordered separately: WB Circuit Breakers (qty. 2, page 6-36), Walking Beam Assembly (page 6-36), Mounting Pan (page 6-36), Neutral (page 6-52) and Service Ground Kit (page 6-52). q For applications above 200 A requiring a neutral, use copper wire only. r Enclosure has blank top endwall. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6-52 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6-52 FA100Y © 2005 Schneider Electric All Rights Reserved 9/16/05 9/16/05 DE1 kDE2A Discount Schedule 6-51 CIRCUIT BREAKERS FAL, FHL, FCL NEMA 1 Flush Ampere Rating 6 Circuit Breaker Catalog Number Prefix