21 next neXt C_GNR_0608 close control air conditioners / heat pumps 22 neXt close control air conditioners / heat pumps VERSIONS: DX (R407C) Cooling capacity 6,7 ÷ 97,0 kW Direct expansion air conditioner in Under and Over versions, for remote air cooled condenser matching. DX.P (R407C) Cooling capacity 7,2 ÷ 102,1 kW Heating capacity 5,5 ÷ 90,4 kW Heat pump air conditioner in Over versions, for remote next/under GENERAL FEATURES air cooled condenser matching. DW (R407C) Cooling capacity 7,0 ÷ 104,1 kW The neXt series air conditioners are the best answer to the need of a precise control of the thermo-hygrometric and air purity conditions in the modern and sophisticated Hi-Tech installations and in the high quality “comfort” applications, granting the optimal environment for electronic equipment to work in and operators wealth. Direct expansion air conditioner in Under and Over versions, with built-in water cooled condenser. DW.P (R407C) Cooling capacity 7,5 ÷ 112,0 kW Heating capacity 6,3 ÷ 103,0 kW Computer rooms, telephone exchanges, internet hotels, Heat pump air conditioner in Over versions, museums, shopping centres are just some of the typical with built-in water cooled condenser. applications of neXt units, whose efficiency, silentness and versatility features are appreciated by the most qualified users worldwide. HIGH DENSITY CW.S Thanks to the layout optimisation of components and Cooling capacity 10,3 ÷ 104,4 kW accessories, the neXt air conditioners can grant a high Chilled water feeding air conditioner in Under and cooling density for those situations where the space Over versions. organization becomes a key-factor same as the capacity. The cooling capacity per unit is up to 60 kW per square meter. CW.K Cooling capacity 13,1 ÷ 161,0 kW High density chilled water feeding air conditioner in Under and Over versions. CW.KC new Cooling capacity 13,1 ÷ 161,0 kW High density chilled water feeding air conditioner C_GNR_0608 in Under and Over versions, with centrifugal fans. RCGROUP SpA neXt 23 close control air conditioners / heat pumps neXt air conditioners are available in Over and Under version, with single or double circuit (DX version). MAIN COMPONENTS • Base and housing in epoxy painted aluminium Up-flow air delivery (Over) The air distribution is from the top of the unit directly in to the room. profile frame and panels in galvanized steel sheet externally coated with PVC film. The air flow in each area is predetermined during the • Plug fans design stage and it is not dependent on the actual state • Scroll compressor (DX – DW) of the load to be dissipated. The system is normally applied in Comfort plants and in those plants having a defined low/medium room thermal loads density. • Refrigerant circuit: single or double DC (DX) • Cycle reversing valve (DX.P – DW.P) • 3-way proportional cooling valve with Down-flow air delivery (Under) The air distribution is from the bottom by means of the plenum between the building floor and the raised floor. emergency manual control (CW – CW.K) • Electrical box in separate compartment This solution is usually applied in hi-tech. room air • Main switch with door lock safety conditioning and it is most favourable when load is • MP.COM microprocessor control uniformly distributed in all areas of the room. MAIN OPTIONAL ACCESSORIES • Serial port • Remote air cooled condenser (DX - DX.P) • EC fans (electronically commutated) • Electric or hot water heating system • Humidification and dehumidification system • Compressor capacity control (DX – DW) • Free-cooling system (DW) • Extra-circuit system (DX – DW – CW) • Hot gas re-heating system (DX-DW) • Plenum on air delivery • High efficiency filters F5/F6/F7/F9 • Compressor cap for noise reduction next RCGROUP SpA C_GNR_0608 next/over 24 neXt close control air conditioners / heat pumps TECHNICAL DATA AND NOMINAL PERFORMANCES neXt.DX under/over MODEL Size Cooling capacity (1) Air flow Compressors Weight Over Under Sound pressure (5) Over Under MODEL Size Cooling capacity (1) Air flow Compressors Weight Over Under Sound pressure (5) Over Under kW m3/h n. kg kg dB(A) dB(A) 007 Z1 H1 6,6 2273 1 009 Z1 H1 8,8 2653 1 011 Z1 H1 9,6 2653 1 013 Z1 H1 10,7 2653 1 015 Z1 H2 13,7 3955 1 017 Z1 H2 16,4 3955 1 021 Z1 H3 19,3 5460 1 023 Z1 H3 20,9 5460 1 025 Z1 H4 25,0 7160 1 029 Z1 H4 29,2 7440 1 033 Z1 H4 32,5 7440 1 186 192 50,4 57,4 189 196 51,4 60,7 190 197 51,4 60,7 191 198 51,4 60,7 246 256 57,0 67,3 247 258 57,0 67,3 306 317 57,8 67,5 307 318 57,8 67,5 421 441 60,6 69,2 421 441 422 442 64,7 72,2 64,7 72,2 026 Z2 H5 24,5 kW 7110 m3/h 2 n. 455 kg 471 kg 57,6 dB(A) 69,1 dB(A) 032 Z2 H5 28,9 7110 2 045 Z1 H5 43,5 10440 1 049 Z1 H5 48,1 10440 1 042 Z2 H6 41,1 11310 2 048 Z2 H6 45,6 11310 2 052 Z2 H6 49,5 13480 2 060 Z2 H6 57,0 14500 2 072 Z2 H7 69,7 17610 2 082 Z2 H7 77,7 20870 2 092 Z2 H7 88,1 22040 2 100 Z2 H7 97,3 22040 2 457 473 57,6 69,1 476 492 66,2 74,9 484 500 66,2 74,9 563 589 57,8 67,3 565 591 57,8 67,3 668 694 61,2 70,8 668 694 64,7 72,5 770 803 64,9 73,1 776 810 67,0 77,9 783 816 812 845 68,4 79,7 68,4 79,7 029 Z1 H4 31,3 28,1 7440 1 429 64,7 033 Z1 H4 34,6 31,5 7440 1 430 64,7 092 Z2 H7 94,6 81,1 22040 2 799 68,4 100 Z2 H7 105,0 90,4 22040 2 828 68,4 neXt.DX.P over - heat pump MODEL Size Cooling capacity (3) Heating capacity (4) Air flow Compressors Weight Sound pressure (5) MODEL Size Cooling capacity (3) Heating capacity (4) Air flow Compressors Weight Sound pressure (5) kW kW m3/h n. kg dB(A) 007 Z1 H1 7,2 5,5 2273 1 190 50,4 kW kW m3/h n. kg dB(A) 026 Z2 H5 26,2 25,4 7110 2 464 57,6 009 Z1 H1 9,5 8,3 2653 1 193 51,4 032 Z2 H5 30,9 32,9 7110 2 466 57,6 011 Z1 H1 10,4 9,6 2653 1 194 51,4 045 Z1 H5 44,6 39,5 10440 1 486 66,2 013 Z1 H1 11,6 11,1 2653 1 195 51,4 049 Z1 H5 48,5 44,1 10440 1 494 66,2 015 Z1 H2 14,7 13 3955 1 251 57,0 042 Z2 H6 43,4 36,5 11310 2 574 57,8 017 Z1 H2 17,7 16,1 3955 1 252 57,0 048 Z2 H6 46,1 39,0 11310 2 576 57,8 021 Z1 H3 20,7 17,4 5460 1 312 57,8 052 Z2 H6 50,6 41,8 13480 2 681 61,2 060 Z2 H6 61,2 52,8 14500 2 681 64,7 023 Z1 H3 22,7 18,9 5460 1 313 57,8 072 Z2 H7 73,8 65,8 17610 2 785 64,9 025 Z1 H4 26,9 22,3 7160 1 429 60,6 082 Z2 H7 83,6 71,4 20870 2 793 67,0 C_GNR_0608 (1) Referred to entering air at 24°C with 50%RH and air to the condenser at 35°C (3) Referred to entering air at 27°C with 47%RH and air to the condenser at 35°C (4) Referred to entering air at 20°C with and outdoor air at 7°C (5) Sound pressure 1m far in free field according to ISO3744 norm. POWER SUPPLY: 400.3.50+N RCGROUP SpA neXt 25 close control air conditioners / heat pumps TECHNICAL DATA AND NOMINAL PERFORMANCES neXt.DW under/over MODEL Size Cooling capacity (1) Air flow Compressors Weight Over Under Sound pressure (5) Over Under MODEL Size Cooling capacity (1) Air flow Compressors Weight Over Under Sound pressure (5) Over Under kW m3/h n. kg kg dB(A) dB(A) 007 Z1 H1 7,0 2273 1 009 Z1 H1 9,2 2653 1 011 Z1 H1 10,3 2653 1 013 Z1 H1 11,7 2653 1 015 Z1 H2 14,9 3955 1 017 Z1 H2 17,3 3955 1 021 Z1 H3 20,4 5460 1 023 Z1 H3 22,6 5460 1 025 Z1 H4 27,0 7160 1 029 Z1 H4 31,5 7440 1 033 Z1 H4 35,1 7440 1 195 211 50,4 57,4 199 216 51,4 60,7 201 218 51,4 60,7 204 221 51,4 60,7 261 271 57,0 67,3 265 275 57,0 67,3 324 339 57,8 67,5 328 339 57,8 67,5 448 468 60,6 69,2 454 474 455 475 64,7 72,2 64,7 72,2 026 Z2 H5 26,9 kW 7110 m3/h 2 n. 483 kg 498 kg 57,6 dB(A) 69,1 dB(A) 032 Z2 H5 31,3 7110 2 045 Z1 H5 47,1 10440 1 049 Z1 H5 52,6 10440 1 042 Z2 H6 44,5 11310 2 048 Z2 H6 49,2 11310 2 052 Z2 H6 54,4 13480 2 060 Z2 H6 63,4 14500 2 072 Z2 H7 75,6 17610 2 082 Z2 H7 84,1 20870 2 092 Z2 H7 95,0 22040 2 100 Z2 H7 104,0 22040 2 490 506 57,6 69,1 512 528 57,6 69,1 519 535 66,2 74,9 599 625 66,2 74,9 601 627 66,2 74,9 707 733 57,8 67,3 711 737 57,8 67,3 819 860 57,8 67,3 830 865 57,8 67,3 840 872 869 902 61,2 70,8 61,2 70,8 029 Z1 H4 33,9 30,8 7440 1 463 60,6 033 Z1 H4 37,7 34,6 7440 1 464 64,7 092 Z2 H7 102,0 88,5 22040 2 857 67,0 100 Z2 H7 112,0 103,0 22040 2 886 68,4 neXt.DW.P over - heat pump MODEL Size Cooling capacity (3) Heating capacity (4) Air flow Compressors Weight Sound pressure (5) MODEL Size Cooling capacity (3) Heating capacity (4) Air flow Compressors Weight Sound pressure (5) kW kW m3/h n. kg dB(A) 007 Z1 H1 7,5 6,3 2273 1 199 50 kW kW m3/h n. kg dB(A) 026 Z2 H5 29,0 27,6 7110 2 493 64,7 009 Z1 H1 10,0 8,6 2653 1 203 50,4 032 Z2 H5 33,7 33,3 7110 2 500 57,6 011 Z1 H1 11,1 10,1 2653 1 205 51,4 045 Z1 H5 50,8 45,0 10440 1 522 57,6 013 Z1 H1 12,6 11,6 2653 1 208 51,4 049 Z1 H5 56,5 53,8 10440 1 529 66,2 015 Z1 H2 16,0 14,7 3955 1 266 57 042 Z2 H6 47,7 42,5 11310 2 611 66,2 017 Z1 H2 18,6 17,5 3955 1 270 57 048 Z2 H6 53,1 46,8 11310 2 613 57,8 021 Z1 H3 22,0 20,2 5460 1 330 56,5 052 Z2 H6 58,5 53,2 13480 2 721 57,8 060 Z2 H6 68,3 63,5 14500 2 725 61,2 023 Z1 H3 24,3 22,7 5460 1 335 57,8 072 Z2 H7 81,3 73,5 17610 2 835 64,7 025 Z1 H4 29,1 25,9 7160 1 457 57,8 082 Z2 H7 91,6 81,1 20870 2 845 64,9 RCGROUP SpA C_GNR_0608 (1) Referred to entering air at 24°C with 50%RH and water to the condenser 30-36°C (3) Referred to entering air at 27°C with 47%RH and water to the condenser 15-30°C (4) Referred to entering air at 20°C and water to the condenser 15-7°C (5) Sound pressure 1m far in free field according to ISO3744 norm. POWER SUPPLY: 400.3.50+N 26 neXt close control air conditioners / heat pumps TECHNICAL DATA AND NOMINAL PERFORMANCES neXt.CW under/over 012 015 022 031 044 066 078 094 114 kW m3/h kg kg dB(A) dB(A) H1 10,3 2653 H2 14,5 3955 H3 22,0 5460 H4 29,6 7440 H5 39,9 10440 H6 59,5 15060 H6 74,6 14850 H7 89,4 22040 H8 104,0 29050 149 166 47,2 42,6 193 204 53,8 49,2 247 257 54,0 49,4 306 326 58,7 54,1 350 365 61,4 56,8 440 466 61,9 57,3 455 481 61,7 57,1 524 557 646 683 66,2 61,6 64,2 59,6 013 020 029 046 068 104 120 142 174 kW m3/h kg kg dB(A) dB(A) H1 13,1 2653 H2 19,1 3870 H3 27,7 5460 H4 41,8 8460 H5 63,6 12390 H6 94,8 18600 H6 112,0 19040 H7 135,0 25340 H8 161,0 30100 155 172 47,2 42,6 200 211 53,8 49,2 258 268 54,0 49,4 295 313 56,7 52,1 390 410 53,6 49,0 495 518 61,8 57,2 515 538 63,1 58,5 630 665 730 780 61,4 56,8 65,6 61,0 MODEL Size Cooling capacity (1) Air flow Weight Over Under Sound pressure (2) Over Under neXt.CW.K under/over MODEL Size Cooling capacity (1) Air flow Weight Over Under Sound pressure (2) Over Under new neXt.CW.KC under/over 013 020 029 046 068 104 120 142 174 kW m3/h kg kg dB(A) dB(A) H1 13,1 2653 H2 19,1 3870 H3 27,7 5460 H4 41,8 8460 H5 63,6 12390 H6 94,8 18600 H6 112,0 19040 H7 135,0 25340 H8 161,0 30100 155 172 47,2 42,6 200 211 258 268 330 348 430 450 550 573 570 593 680 715 780 830 53,8 49,2 54,0 49,4 60,5 55,9 60,7 56,1 64,9 60,3 65,8 61,2 65,3 60,7 67,8 63,2 MODEL Size Cooling capacity (1) Air flow Weight Over Under Sound pressure (2) Over Under (1) Referred to entering air at 24°C with 50%RH and chilled water temperature 7/12,5°C (2) Sound pressure 1m far in free field according to ISO3744 norm. POWER SUPPLY: 400.3.50+N DIMENSIONS (mm) Size a b c H1 650 650 1.925 H2 785 650 1.925 H3 1.085 750 1.925 H4 1.320 860 1.980 H5 1.620 860 1.980 H6 2.155 860 1.980 H7 2.690 860 1.980 H8 3.225 860 1.980 c a b Te l . + 3 9 0 3 8 2 4 3 3 8 1 1 • w w w. r c g r o u p . i t • s a l e s @ r c g r o u p . i t Technical data and dimensions are not binding. RC GROUP S.p.A. reserves the right for changes and /or modifications without notice.