Overhead Aluminium Conductor s Aberdare, cables you can trust Revised 012008 C O M PA N Y P R O F I L E Aberdare Cables, a member of the Powertech Group, is a leading African manufacturer of cables and distributor of electrical accessories. With manufacturing sites in three provinces of South Africa, and offshore operations in Mozambique, Portugal and Spain, Aberdare Cables manufactures an extensive range of electrical cables for application in power transmission, power distribution, rail, petrochemical, mining, ports, airports, wholesale, construction and domestic building environments. Aberdare Cables prides its self on its ability to identify and satisfy customer needs through development of innovative products; unique, cost effective cable solutions for a wide range of industries. This and their extensive project experience make them the supplier of choice for cable, electrical accessories (switches, sockets, circuit breakers and reticulation) and special cable projects. Technology focus Aberdare Cables pursues on-going technology development programmes, and through active association with its local and overseas affiliates, continues to remain at the forefront of technology.The company has been recognised internationally as a pioneer in cable advancements. Aberdare serves on a number of SABS and International Electro Technical Commission (IEC) cable working groups. As much as ten years ago, in a move towards facilitating the provision of electricity for all countrywide, Aberdare Cables designed products with an emphasis on cost efficiency of electrification.To this end, Aberdare created its Electrodac range, which is aimed specifically at facilitating rural electrification by lowering the cost of electricity delivery. More recently, in accordance with Siemens specifications, Aberdare produced an unarmoured cable, with stringent fire characteristics, that was designed to reduce the propagation of fire by cables.This cable is used at Eskom's open-cycle gas turbine generators at Mossel Bay and Atlantis.To cater for international markets, Aberdare introduced fire survival cable with stringent properties that allow continuous operation and circuit integrity for extended periods during a fire. Quality focus Aberdare Cables is a forerunner in the industry with regard to quality. The manufacturing, quality assurance, testing and research resources of Aberdare are of a world-class standard. In fact, the company was one of the first companies in South Africa to be awarded the South African Bureau of Standards (SABS) Quality Assurance Certification, and has been ISO 9001 compliant for many years. Aberdare Cables is UL listed and has Basec QA accreditation. Transformation focus Aberdare has embraced the empowerment concept. Today, Izingwe Consortium owns 30% of the company and the company has assisted in the development of a number of black enterprises, such as DRUMCO, the company that makes Aberdare Cable Drums. At Aberdare, education, training and development are seen as a foundation for economic productivity and as crucial tools to build empowered and dedicated employees. In this regard, the company actively promotes and follows a number of education programmes, including adult education, apprentices, trainees, learnerships and formal education assistance. Aberdare Cables has always been an active supporter and pillar of strength for the communities in which it operates. The company is championing a number of social investment initiatives across our country. The biggest of these investments has been the continuous sponsorship of Sinethemba home for street children in Port Elizabeth. As a proudly South African company, Aberdare participated actively in the development of the ICT charter and the draft DTI BBBEE codes. Aberdare will continue to adopt a proactive approach to effect the transformation that the codes specify and to lead the cable industry in this regard. We enjoy a BBBEE status of Level 3. Index Aberdare, cables you can trust Overview i-ii ACSR 1 Canadian Standard Sizes 2-4 British Standard Sizes 5 Extra Strong 6 Australian Standard Sizes 7 Australian Standard Sizes, Extra Strong 7 South African Standard Sizes 8 AAC 9 British Standard Sizes 10 Canadian Standard Sizes 11 South African Standard Sizes 12 Australian Standard Sizes 12 AAAC 13 Australian Standard Sizes 14 British Standard Sizes 15 American Standard Sizes 16 Product Range 17 Over view Aberdare, cables you can trust Aluminium conductors have achieved wide acceptance all over the world for use in overhead transmission and distribution lines. Generally a steel core is used with the aluminium to give the conductor mechanical strength. This arrangement is termed Aluminium Conductor Steel Reinforced or ACSR. Conductors comprised entirely of aluminium are known as All Aluminium Conductors or AAC.These conductors are extensively used for busbars in outdoor substations where spans are short. All Aluminium Alloy Conductors or AAAC consist of an alloying of aluminium to give a tensile strength in excess of that of AAC, allowing longer spans. These conductors are recommended for coastal areas where severe corrosion is a problem. Hard drawn aluminium in H9 temper is used in both ACSR and AAC. High strain steel wire is used in ACSR and this is sometimes protected from corrosion by an application of grease. Such measures are particularly adopted when the conductor is intended for use in aggressive environments as encountered in coastal regions. Aberdare Power Cables Division manufactures a wide range of AAC, ACSR and AAAC to customer’s requirements or national specifications. The information contained in the following tables relates to the more popular sizes and standards using the following conditions: • AmbientTemperature 30°C • Maximum ConductorTemperature 75°C • Wind Speed 0,44m/s • Normal StringingTemperature 25°C • Solar Radiation 890W/m² • Solar Absorption Coeficient 1 Sag and Tension charts are available on request. The following information to be supplied: • Span length • Maximum design load (25% of UTS if not specified) • Stringing temperature i Over view Aberdare, cables you can trust Comparison of Characteristics of Copper and Aluminium Material Copper Aluminium Al Alloy 8,89 2,70 2,70 367 160 - Specific gravity Tensile strength: MPa Hard drawn Annealed Volume resistivity at 20°C Ω.m 248 100 295 1,724 x 10-8 2,826 x 10-8 3,253 x 10-8 Temperature coefficient of resistance per °C 0,00393 0,00403 0,00360 Coefficient of linear expansion per °C 17 x 10-6 23 x 10-6 23 x 10-6 Specific heat KJ/kg/K 0,394 0,904 0,904 Melting point °C 1083 658 658 Chemical Characteristics of Rod Aluminium Code Si 99,7 EC Fe B Mn+Ti+V+Cr Al % min. - 0,16 0,003 - 99,65 % nom. - 0,22 0,005 - 99,70 % max. 0,10 0,28 0,020 0,013 - Alloy Si Mg % min. 0,40 % nom. 0,45 Code LA601/2 % max. 0,50 Fe B 0,50 0,15 0,004 0,55 0,20 0,007 0,020 0,60 0,25 Mn+V+Cr - Ti - Zn - - - 0,03 0,013 0,007 - Others 0.01 max. - remainder aluminium Mechanical Characteristics of Rod Description Tensile MPa Elongation % Aluminium Alloy 110-130 170-200 6-12 8-12,5 6-12 8-12,5 Conductivity 62,3 min. 52,5 min. Diameter mm 9,55 nom. 9,55 nom. Firm/Association Trade Name Nearest Equivalents for SIMAG Country U.S.A Canada Switzerland Aluminium Association 6201 Alcan Arvidal Alusuisse Aldrey VMW Austria Ranshofen Elran Berndorf France England Pechiney Almelec Awco Silmalec ii ACSR Aluminium Conductor Steel Reinforced 1 2 85,01 85,01 95,60 95,60 107,20 107,20 107,20 126,70 126,70 126,70 152,00 152,00 152,00 152,00 159,40 WAXWING PIPER OSTRICH ORIOLE LINNET MERLIN CHICADEE LARK IBIS PELICAN FLICKER HEN HAWK HERON 9,84 9,60 8,04 4,14 7,17 3,47 3,77 8,76 7,32 8,07 6,75 3,09 7,62 6,36 5,37 22,96 22,40 21,80 20,70 21,49 17,37 18,87 20,44 19,88 18,83 18,31 15,47 17,78 17,28 16,09 253,49 241,27 241,64 242,31 241,59 170,22 200,93 200,89 201,34 170,50 170,56 134,98 152,01 152,19 135,38 8,34 10,60 13,30 16,83 21,18 26,69 33,59 42,41 53,52 67,33 85,11 107,22 134,88 3,99 4,50 5,04 5,67 6,36 7,14 8,01 9,00 10,11 11,34 12,75 14,31 16,28 OWL mm² mm mm 5,26 6,63 8,37 10,55 13,30 16,77 21,15 26,67 36,62 42,41 53,49 67,43 85,01 Aluminium area 1,33 1,50 1,68 1,89 2,12 2,38 2,67 3,00 3,37 3,78 4,25 4,77 6,00 mm 6/1/1,33 6/1/1,50 6/1/1,68 6/1/1,89 6/1/2,12 6/1/2,38 6/1/2,67 6/1/3,00 6/1/3,37 6/1/3,78 6/1/4,25 6/1/4,77 26/2,57 +7/2,00 6/5,36 +7/1,79 18/1/3,09 30/7/2,54 26/2,73 +7/2,12 30/7/2,69 26/2,89 +7/2,25 18/1/3,47 18/1/3,77 30/7/2,92 26/3,14 +7/2,44 18/1/4,14 24/3,58 +7/2,39 30/7/3,20 26/3,44 +7/2,68 30/7/3,28 mm² Overall diameter Diameter over steel Stranding and wire diameter Equival. copper area WREN WARBLER TURKEY THRUSH SWAN SWALLOW SPARROW ROBIN RAVEN QUAIL PIGEON PENGUIN PARTRIDGE Code name 59,15 56,30 39,49 13,46 31,40 9,46 11,16 46,88 32,73 39,78 27,83 7,50 35,47 24,71 17,62 1,39 1,77 2,22 2,81 3,53 4,45 5,60 7,07 8,92 11,22 14,19 17,87 21,99 mm² Steel area 22,90 29,20 36,60 46,30 58,30 73,40 92,40 117 147 185 234 295 373 372 373 421 421 472 472 470 555 557 557 669 668 668 669 702 153,00 142,48 187,48 176,90 210,28 198,39 179,68 212,09 247,77 234,07 255,77 272,99 297,57 281,13 312,64 Aluminium 9,73 12,37 15,52 19,64 24,71 31,14 39,19 49,48 62,44 78,55 99,30 125,09 156,87 mm² Total area 468 445 312 106 248 74,40 87,90 371 259 315 220 59 280 195 139 10,90 13,90 17,40 22,10 27,80 35,00 44,10 55,60 70,20 88,30 112 141 174 Steel Mass kg/km Total 1170 1110 981 775 916 544 643 928 816 787 692 432 701 616 511 33,80 43,10 54,00 68,40 86,10 108 137 173 217 273 346 436 547 108000 103000 84300 53800 75600 38300 44900 86300 71000 74200 61200 30800 66900 55200 43600 4100 4780 5600 6700 8080 9850 12100 15000 18700 23300 29300 36800 49800 Newton Ultimate tensile strength MPa 71100 65000 60500 57000 54500 52600 51200 50200 49400 49000 48600 48500 52400 47800 41900 55900 51500 55300 50900 41300 41000 54500 50100 40700 47300 53900 49500 53700 /C° x 10-6 19,31 19,31 19,31 19,31 19,31 19,31 19,31 19,31 19,31 19,31 19,31 19,31 19,37 19,90 21,44 18,43 19,38 18,43 19,37 21,44 21,44 18,43 19,38 21,44 19,91 18,43 19,36 18,43 Initial modulus of elasticity Coefficient of linear expansion 83400 83400 77100 66200 73900 66200 66200 83400 77000 83400 77100 66200 83400 77000 76500 80400 80400 80400 80400 80400 80400 80400 80400 80400 80400 80400 80400 77100 MPa Final modulus of elasticity 0,1140 0,1198 0,1195 0,1189 0,1195 0,1686 0,1427 0,1438 0,1434 0,1695 0,1692 0,2126 0,1901 0,1897 0,2119 m 3000 3000 3000 3000 3000 3000 2500 2500 2000 1500 1500 1500 1500 1000 2000 2000 2000 2000 2000 2000 2000 1500 1500 1000 2000 2000 2000 2000 75 87 100 120 130 150 180 210 240 270 320 370 420 420 420 460 460 490 490 480 530 550 540 600 610 610 610 630 Standard drum length A Ω/km 3,4423 2,7062 2,1574 1,7046 1,3548 1,0750 0,8541 0,6766 0,5361 0,4261 0,3371 0,2676 0,2140 Current rating DC resistance at 20°C Aluminium Conductor Steel Reinforced - ACSR (Canadian Standard Sizes) 3 mm 18/1/4,47 24/3,87 +7/2,58 30/7/3,46 26/3,72 +7/2,89 24/4,03 +7/2,69 26/3,87 +7/3,01 30/3,61 +19/2,16 54/7/2,69 18/1/4,78 24/4,14 +7/2,76 30/3,70 +19/2,22 26/3,97 +7/3,09 54/7/2,76 24/4,20 +7/2,82 54/7/2,82 30/3,92 +19/2,35 26/4,21 +7/3,28 54/7/2,92 45/3,38 +7/2,25 30/4,14 +19/2,48 26/4,44 +7/3,45 54/7/3,08 54/7/3,23 54/7/3,28 45/3,70 +7/2,47 mm² 177,40 177,40 192,80 192,80 192,80 192,80 197,04 202,70 202,70 202,70 202,70 212,30 212,30 228,00 228,00 228,00 253,40 253,40 253,40 253,40 278,70 286,80 304,00 EAGLE DOVE PEACOCK SQUAB TEAL DUCK KINGBIRD ROOK EGRET GROSBEAK GOOSE FLAMINGO GULL REDWING STARLING CROW TERN MALLARD DRAKE CONDOR CRANE CANARY RAIL mm 22,33 23,22 24,22 23,55 24,21 24,54 25,25 24,21 23,90 24,82 25,90 25,15 24,84 25,38 25,38 27,43 26,68 26,28 27,00 28,96 28,11 27,76 29,11 29,51 29,59 4,47 7,74 10,38 8,67 8,07 9,03 10,80 8,07 4,78 8,28 11,10 9,27 8,28 8,46 8,46 11,75 9,84 8,76 6,75 12,40 10,35 9,24 9,69 9,84 7,41 Overall diameter (Std.) mm Diameter over steel Stranding and wire diameter 177,40 177,40 Equival. copper area OSPREY PARAKEET Code name 402,33 442,47 456,28 483,84 402,56 403,84 361,62 403,77 361,93 337,27 362,06 323,07 337,27 321,84 322,56 306,89 323,01 323,07 307,06 305,83 306,13 282,07 282,59 282,47 282,31 mm² Aluminium area 52,15 57,36 59,15 33,54 65,44 91,78 46,88 27,83 59,15 43,72 82,41 41,88 43,72 52,49 73,54 39,78 17,95 41,88 69,62 49,81 39,78 65,82 45,92 15,69 36,60 mm² Steel area 454,49 499,83 515,43 517,39 468,00 495,62 408,49 431,60 421,08 380,99 444,47 364,95 380,99 374,34 396,11 346,68 340.96 364,95 376,68 355,64 345,92 347,89 328,50 298,17 318,90 mm² Total area 1120 1230 1260 1340 1110 1120 1000 1120 1000 935 1000 895 932 891 894 851 896 893 851 847 846 781 782 780 780 Aluminium 412 453 468 265 517 728 371 220 468 346 654 331 346 415 583 315 142 331 552 394 315 520 363 124 289 Steel Mass kg/km 1530 1680 1730 1610 1630 1850 1370 1340 1470 1280 1650 1230 1278 1310 1480 1170 1038 1224 1400 1240 1161 1300 1150 904 1069 Total 125000 137000 141000 117000 137000 170000 113000 98700 124000 106000 154000 102000 103000 111000 139000 97500 71320 99200 132000 105000 94400 119000 97400 62500 87300 Newton Ultimate tensile strength MPa 19,91 19,91 19,91 21,11 19,38 18,50 19,91 21,12 19,36 19,91 18,49 19,91 19,91 19,37 18,49 19,91 21,69 19,91 18,50 19,37 19,91 18,43 19,38 47500 47200 47100 42400 48400 53400 47800 42900 48600 48100 53800 48300 46500 48800 54200 48600 40400 46500 54400 48900 46700 53400 49000 40500 46800 /C° x 10-6 21,44 19,91 Initial modulus of elasticity Coefficient of linear expansion 73200 73200 73200 66700 77000 81900 73200 66600 77100 73200 81900 73200 73800 77100 81900 73200 66200 73800 81800 77100 73900 83400 77000 66200 73800 MPa Final modulus of elasticity A 0,0718 0,0653 0,0634 0,0598 0,0717 0,0716 0,0799 0,0718 0,0798 0,0857 0,0798 0,0895 0,0856 0,0897 0,0896 0,0942 0,0891 0,0894 0,0941 0,0944 0,0943 0,1024 0,1021 830 880 900 920 830 840 780 830 780 740 790 720 740 730 730 700 710 720 710 700 700 670 670 660 670 Ω/km 0,1018 0,1023 Current rating DC resistance at 20°C Aluminium Conductor Steel Reinforced - ACSR (Canadian Standard Sizes) 2000 2000 2000 2000 1500 1000 1500 1500 1000 2000 1000 2000 1000 1000 1000 2000 2000 1500 1500 1500 1500 2000 1500 1500 2000 m Standard drum length 4 mm 54/7/3,38 45/3,85 +7/2,57 54/7/3,52 45/4,00 +7/2,66 54/3,65 +19/2,19 45/4,14 +7/2/76 54/3,77 +19/2,27 45/4,27 +7/2,85 54/3,90 +19/2,34 45/4,40 +7/2,92 54/4,02 +19/2,41 45/4,53 +7/3,02 54/4,14 +19/2,48 45/4,65 +7/3,10 54/4,25 +19/2,55 45/4,77 +7/3,18 54/4,36 +19/2,62 84/3,70 +19/2,22 mm² 329,40 354,70 354,70 380,00 380,00 405,40 405,40 430,70 430,70 456,00 456,00 481,40 481,40 506,70 506,70 567,00 CURLEW BLUEJAY FINCH BUNTING GRACKLE BITTERN PHEASANT DIPPER MARTIN BOBLINK PLOVER NUTHATCH PARROT LAPWING FALCON CHUKAR mm 30,38 30,81 31,65 31,98 32,84 33,07 33,99 34,16 35,36 35,18 36,17 36,25 37,21 37,21 38,25 38,15 39,24 40,69 mm 10,56 7,98 10,95 8,28 11,35 8,55 11,70 8,76 12,05 9,06 12,40 9,30 12,75 9,54 13,10 11,10 Overall diameter (Std.) 10,14 7,71 Diameter over steel Stranding and wire diameter 305,00 329,40 Equival. copper area CARDINAL ORTLAN Code name 903,18 806,23 804,15 766,06 764,20 726,92 725,27 685,39 684,24 645,08 644,40 602,79 605,76 565,03 525,50 565,49 484,53 523,87 mm² Aluminium area 1340 1450 593,62 604,39 636,60 647,64 679,68 689,06 726,79 731,12 772,06 775,41 818,70 817,04 863,09 859,75 908,66 976,72 68,12 38,90 71,57 41,88 76,89 44,66 81,71 46,88 86,67 50,14 91,78 52,83 97,03 55,60 102,43 73,54 2497 2230 2220 2120 2110 2010 2010 1900 1890 1790 1780 1670 1680 1570 1460 1560 Aluminium mm² 547,33 560,18 mm² Total area 62,81 36,31 Steel area 2000 1870 2138 2010 2280 2130 2440 2260 2590 2410 2740 2530 2890 2660 3040 3080 539 308 568 331 610 353 648 371 687 396 728 418 770 440 813 583 Total 1840 1740 497 287 Steel Mass kg/km 233000 246000 190000 234000 181000 222000 172000 210000 162000 199000 154000 187000 145000 176000 161000 135000 149000 126000 Newton Ultimate tensile strength MPa 46900 42200 46700 42000 47300 41900 47100 41900 46900 41700 46700 417,00 46500 41600 46400 41600 46400 43600 /C° x 10-6 19,91 21,11 19,91 21,13 19,97 21,12 19,95 21,11 19,97 21,13 19,97 21,12 19,97 21,12 19,97 21,12 19,96 20,85 Initial modulus of elasticity Coefficient of linear expansion 67500 72300 66700 72300 66700 72200 66700 72300 66500 72300 66700 72300 66700 72300 73200 66600 73200 66700 MPa Final modulus of elasticity A 0,0321 0,0359 0,0359 0,0377 0,0378 0,0398 0,0399 0,0422 0,0422 0,0448 0,0449 0,0480 0,0478 0,0512 0,0550 0,0513 1300 1300 1300 1200 1200 1200 1200 1100 1100 1100 1100 1100 1100 1000 980 1000 930 970 Ω/km 0,0597 0,0552 Current rating DC resistance at 20°C Aluminium Conductor Steel Reinforced - ACSR (Canadian Standard Sizes) 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 2000 2000 1000 2000 2000 m Standard drum length 5 151,80 161,85 194,94 226,20 261,54 293,86 326,12 399,98 462,63 422,60 431,18 529,84 484,48 588,46 537,66 596,99 744,84 747,96 20,06 30,62 36,88 42,80 49,48 55,60 61,70 75,67 87,53 48,50 49,48 100,24 55,60 111,33 61,70 68,51 83,11 60,60 131,74 131,23 158,06 183,41 212,06 238,27 264,42 324,31 375,11 374,11 381,70 429,60 428,88 477,13 475,96 528,49 661,73 687,36 15,89 16,52 18,13 19,53 21,00 22,26 23,45 25,97 27,93 26,73 27,00 29,89 28,62 31,50 30,15 31,77 35,50 35,58 5,73 4,72 7,77 8,37 9,00 9,54 10,05 11,13 11,97 8,91 9,00 12,81 9,54 13,50 10,05 10,59 11,80 9,96 80,65 96,77 112,90 129,00 145,20 161,30 193,50 225,80 225,80 225,80 258,10 258,10 290,30 290,30 322,60 414,63 430,70 TIGER WOLF LYNX PANTHER LION BEAR GOAT SHEEP ANTELOPE BISON DEER ZEBRA ELK CAMEL MOOSE DINOSAUR BERSFORD 80,65 COYOTE 148,21 16,84 131,37 15,81 5,25 80,65 LEOPARD 126,43 20,48 105,95 14,57 5,79 64,52 1,77 3,50 4,37 5,27 6,11 7,07 8,81 10,52 36,88 12,50 42,80 13,14 13,99 15,90 17,50 13,55 HYENA mm² 12,37 24,48 30,62 36,88 42,80 49,48 61,70 73,65 100,10 87,53 116,16 91,97 97,91 111,33 122,48 118,53 mm² mm² 6,45 12,90 16,30 19,35 22,58 25,81 32,26 38,71 38,71 45,16 45,16 48,39 51,61 58,06 64,52 64,52 10,60 20,98 26,25 31,61 36,68 42,41 52,88 63,13 63,22 75,02 73,36 78,83 83,92 95,43 104,98 104,98 mm 6/1/1,50 6/1/2,11 6/1/2,36 6/1/2,59 6/1/2,79 6/1/3,00 6/1/3,35 6/1/3,66 12/7/2,59 6/1/3,99 12/7/2,79 6/1/4,09 6/1/4,22 6/1/4.50 6/1/4,72 6/4,72 +7/1,57 7/4,39 +7/1,93 6/5,28 +7/1,75 26/2,54 +7/1,91 30/7/2,36 30/7/2,59 30/7/2,79 30/7/3,00 30/7/3,18 30/7/3,35 30/7/3,71 30/7/3,99 54/7/2,97 54/7/3,00 30/7/4,27 54/7/3,18 30/7/4,50 54/7/3,35 54/7/3,53 54/3,95 +19/2,36 48/4,27 +7/3,32 mm² 4,50 6,33 7,08 7,77 8,37 9,00 10,05 10,98 12,95 11,97 13,95 12,27 12,66 13,50 14,16 14,15 Total area mm Steel area 1,50 2,11 2,36 2,59 2,79 3,00 3,35 3,66 7,77 3,99 8,37 4,09 4,22 4,50 4,72 4,71 Aluminium area mm Overall diameter (Std.) Diameter over steel Stranding and wire diameter Equival. copper area MOLE SQUIRREL GOPHER WEASEL FOX FERRET RABBIT MINK SKUNK BEAVER HORSE RACCOON OTTER CAT HARE DOG Code name 1906 364 438 508 588 660 733 899 1040 1040 1060 1190 1190 1320 1320 1460 1835 365 361 291 29,20 57,70 72,20 87,00 101 117 145 174 175 206 203 217 231 263 289 289 Aluminium 480 242 292 330 391 440 488 598 692 383 391 792 440 880 488 542 658 159 133 162 13,90 27,50 34,40 41,50 48,10 55,60 69,40 82,80 292 98,40 338 103 110 125 138 100 Steel Mass kg/km Total 2386 606 730 846 970 1100 1220 1500 1730 1420 1450 1980 1630 2200 1810 2000 2493 524 494 453 43,10 85,20 107 129 149 173 214 257 467 304 541 320 341 388 427 389 177650 58700 69200 79300 90800 101000 112000 136000 157000 117000 119000 179000 133000 199000 147000 162000 202920 47300 42200 41900 4780 8020 9610 11450 13100 15200 18500 21900 52900 25900 60700 27200 28900 32800 36000 34700 Newton Ultimate tensile strength MPa 20,68 18,43 18,43 18,43 18,43 18,43 18,43 18,43 18,43 19,91 19,91 18,43 19,91 18,43 19,91 19,91 19,91 19,54 19,54 18,93 43200 56900 55700 54900 54300 53900 53600 53100 52900 47700 47600 52800 47300 52700 47000 46700 46700 51900 47800 52400 65000 54600 52700 51500 50700 50200 49500 49100 71900 48800 71000 48700 48700 48500 48500 48800 /C° x 10-6 19,31 19,31 19,31 19,31 19,31 19,31 19,31 19,31 15,84 19,31 15,84 19,31 19,31 19,31 19,31 19,92 Initial modulus of elasticity Coefficient of linear expansion 68800 83400 83400 83400 83400 83400 83400 83400 83400 73200 73200 83400 73200 83400 73200 73200 72200 76000 76300 82200 80400 80400 80400 80400 80400 80400 80400 80400 108000 80400 108000 80400 80400 80400 80400 76400 MPa Final modulus of elasticity 0,0420 0,2202 0,1828 0,1576 0,1363 0,1213 0,1093 0,0891 0,0770 0,0773 0,0757 0,0673 0,0674 0,0606 0,0607 0,0547 0,0437 0,3035 0,2184 0,2697 1132 420 470 520 560 610 650 730 800 790 800 870 860 930 920 980 1110 420 410 360 87 130 150 170 190 210 240 260 270 290 300 300 310 340 360 360 A Ω/km 2,7062 1,3677 1,0933 0,9077 0,7822 0,6766 0,5426 0,4546 0,4571 0,3825 0,3939 0,3640 0,3419 0,3007 0,2733 0,2733 Current rating DC resistance at 20°C Aluminium Conductor Steel Reinforced - ACSR (British Standard Sizes) 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 1500 2000 2000 2000 2000 2000 2000 3000 3000 3000 2500 2500 1500 1500 1500 2000 1500 2000 1500 1500 1500 1500 2000 m Standard drum length 6 4,18 6,65 10,57 16,81 21,20 25,49 32,51 35,32 42,87 50,67 56,35 60,80 64,71 64,76 67,34 PETREL MINORCA LEGHORN GUINEA DOTTEREL DORKING AUK BRAHMA COCHIN 12,41 10,11 7,02 7,32 8,07 8,77 9,25 9,61 6,74 4,24 mm mm 3/4/1,68 3/4/2,118 3/4/2,672 3/4/3,371 3/4/3,785 8/2,540 +1/4,242 12/7/2,339 12/7/2,441 12/7/2,690 12/7/2,924 12/7/3,084 12/7/3,204 8/4,046 +7/2,248 16/19/2,863 12/7/3,371 mm² Diameter over steel Stranding and wire diameter Equival. copper area BANTAM MAGPIE SHRIKE SNIPE LOON GROUSE Code name mm² 8,83 14,13 22,45 35,68 44,97 14,13 30,07 32,77 39,81 46,92 52,29 56,39 27,80 91,80 62,40 mm² 6,65 10,58 16,84 26,71 33,74 40,52 51,61 56,13 68,19 80,58 89,61 96,71 102,80 103,00 107,10 11,71 12,22 13,46 14,63 15,42 16,03 14,83 18,14 16,87 Steel area 5,03 6,35 8,03 10,11 11,35 9,32 Aluminium area mm Overall diameter (Std.) 194,80 169,50 81,89 88,90 108,00 127,50 141,90 153,10 130,60 15,48 24,71 39,29 62,39 78,71 54,65 mm² Total area 285,50 295,10 142,10 154,70 188,00 222,10 246,90 266,30 282,10 18,21 28,90 46,00 73,20 92,30 111,20 Aluminium Total 87,80 139,70 222,30 353,60 445,90 221,10 376,90 410,30 498,30 588,80 654,70 706,60 498,90 1005 782,40 Steel 69,59 110,80 176,30 280,40 353,60 109,60 234,80 255,60 310,30 366,70 407,80 440,30 216,70 719,50 487,30 Mass kg/km 122543 87396 43835 47719 57516 67567 73108 78874 49621 11679 18573 28547 43923 55300 23153 Newton Ultimate tensile strength MPa 14,22 15,30 15,30 15,30 15,30 15,30 15,30 15,30 17,64 115830 104800 104800 104800 104800 104800 104800 104800 86870 133760 133760 133760 133760 133760 93770 /C° x 10-6 13,68 13,68 13,68 13,68 13,68 16,92 Final modulus of elasticity Coefficient of linear expansion Aluminium Conductor Steel Reinforced - ACSR (Extra Strong) 0,281 0,270 0,567 0,512 2,422 0,358 0,321 0,299 0,278 360 356 232 244 275 304 325 339 346 69 92 122 162 186 195 A Ω/km 4,303 2,707 1,705 1,070 0,849 0,707 Current rating DC resistance at 20°C 1500 1500 2000 1500 2000 1500 2000 2000 2000 3000 3000 2500 2000 1500 1500 m Standard drum length 7 17,50 21,00 24,50 27,00 29,25 31,50 33,75 42,75 7,50 9,00 10,50 9,00 9,75 10,50 11,25 14,25 1521,49 181,62 407,91 261,54 587,41 355,98 799,51 431,18 1057,31 506,04 1240,88 586,89 1439,13 671,96 1652,06 1078,12 2650,64 34,36 49,48 67,35 49,48 58,07 67,35 75,55 121,21 147,26 212,06 288,63 381,70 447,97 519,54 596,41 956,91 80,99 116,23 182,24 292,38 34,36 49,48 77,31 120,39 4,91 7,07 11,04 14,07 Aluminium mm² mm² Total area mm² Steel area 29,45 42,41 66,27 106,32 Aluminium area 962,41 271,79 391,39 532,74 391,38 459,33 532,74 599,87 38,59 55,57 86,77 111,01 Steel Mass kg/km Total 65000 90800 122000 119000 138000 159000 185000 10700 15000 22900 35500 Newton 3613,05 289000 679,70 978,80 1332,25 1448,69 1700,21 1971,87 2251,93 119,58 171,80 269,01 403,39 Ultimate tensile strength MPa 20,0 18,4 18,4 18,4 19,9 19,9 19,9 20,0 46100 56100 54300 53400 47600 47100 46800 47100 51900 50200 49000 49000 /C° x 10-6 19,3 19,3 19,3 19,9 Initial modulus of elasticity Coefficient of linear expansion 72300 83400 83400 83400 73200 73200 73200 72300 80400 80400 80400 76700 MPa Final modulus of elasticity A 0,0302 0,1962 0,1363 0,1001 0,0757 0,0645 0,0556 0,0485 1380 445 558 676 795 877 960 1040 163 204 269 361 Ω/km 0,9742 0,6766 0,4330 0,2699 Current rating DC resistance at 20°C 1000 2000 2000 2000 2000 2000 2000 1000 3000 3000 3000 1000 m Standard drum length mm mm 3/4/1,75 3/4/2,50 4/3/3,00 4/3/3,75 mm² 11,48 23,42 44,95 70,25 * * * * Diameter over steel Stranding and wire diameter Equival. copper area 5,25 7,50 9,00 11,25 mm Overall diameter (Std.) * Steel strands mixed in layer with aluminium strands QUINCE RAISIN SULTANA WALNUT Code name 7,22 14,73 28,27 44,18 mm² Aluminium area 9,62 19,63 21,21 33,131 mm² Steel area 16,84 34,36 49,48 77,31 mm² Total area 19,78 38,99 77,46 121,05 Aluminium 75,61 154,29 166,71 260,40 Steel Mass kg/km Total 95,39 193,28 244,17 381,45 12700 24400 28300 43900 Newton Ultimate tensile strength MPa 133760 133760 122000 122000 MPa - /C° x 10-6 13,9 13,9 15,2 15,2 Initial modulus of elasticity Coefficient of linear expansion Final modulus of elasticity 79 115 167 220 A Ω/km 3,9377 1,9295 1,0048 0,6431 Current rating DC resistance at 20°C 3000 3000 3000 3000 m Standard drum length Aluminium Conductor Steel Reinforced - ACSR (Australian Standard Sizes) (Extra Strong Constructions) PEACH 234,14 337,18 458,92 606,90 712,27 826,07 948,29 7,50 9,00 11,25 14,30 GRAPE LEMON LIME MANGO ORANGE OLIVE PAWPAW mm 46,83 67,43 105,37 169,05 2,50 3,00 3,75 4,80 mm 6/1/2,50 6/1/3,00 6/1/3,75 6/4,75 & 7/1,60 30/7/2,50 30/7/3,00 30/7/3,50 54/7/3,00 54/7/3,25 54/7/3,50 54/3,75 & 19/2,25 54/4,75 & 19/2,85 mm² mm Overall diameter (Std.) Diameter over steel Stranding and wire diameter Equival. copper area ALMOND APPLE BANANA CHERRY Code name Aluminium Conductor Steel Reinforced - ACSR (Australian Standard Sizes) 8 18,31 23,69 28,91 35,94 7,77 10,05 9,54 11,85 * Standard British Sizes 96,4 161 262 404 6,33 7,16 8,45 9,09 10,15 11,09 14,30 14,29 158/37 264/62 429/56 662/84 mm 2,11 2,36 2,79 3,00 3,35 3,66 4,72 4,71 mm 6/1/2,11 6/1/2,36 6/1/2,79 6/1/3,00 6/1/3,35 6/1/3,66 6/1/4,72 6/4,75 +7/1,57 30/7/2,59 30/7/3,35 54/7/3,18 54/3,95 +19/2,37 mm² mm Overall diameter (Std.) Diameter over steel Stranding and wire diameter 12,8 16,0 22,4 25,8 32,3 38,5 64,0 64,0 Equival. copper area * 21/3,5 * 26/4,4 * 37/6,1 * 42/7,1 * 53/8,8 * 63/11 105/17 105/14 Code name 158 264 429 662 20,9 26,3 36,7 42,4 52,9 63,1 105 105 mm² Aluminium area Aluminium 58 72 100 117 145 173 288 292 436 729 1185 1826 mm² 24,5 30,6 42,8 49,5 61,7 73,7 122 118 195 326 484 746 3,5 4,4 6,1 7,1 8,8 10,5 17,5 12,7 36,9 61,7 55,6 83,8 Total area mm² Steel area Total 85 106 148 172 214 255 425 394 726 1214 1621 2489 Steel 27 34 48 55 69 83 137 102 290 485 436 663 Mass kg/km 69250 111400 131900 205500 7710 9610 13150 15200 18400 22500 36540 32640 Newton Ultimate tensile strength MPa 54600 52700 50700 50200 49500 49100 48500 48800 55700 53600 47300 46900 /C° x 10-6 19,31 19,31 19,31 19,31 19,31 19,31 19,31 19,92 18,43 18,43 19,91 19,96 Initial modulus of elasticity Coefficient of linear expansion 83400 83400 73200 72300 80400 80400 80400 80400 80400 80400 80400 76400 MPa Final modulus of elasticity A 0,186 0,111 0,0687 0,0445 470 650 860 1123 130 150 190 210 240 260 360 360 Ω/km 1,395 1,116 0,798 0,690 0,553 0,463 0,278 0,278 Current rating DC resistance at 20°C Aluminium Conductor Steel Reinforced - ACSR ( South African Standard Sizes) 2000 2000 1500 1000 3000 3000 2500 1500 1500 1500 1500 2000 m Standard drum length AAC All Aluminium Conductor 9 10 MIDGE APHIS GNAT WEEVIL MOSQUITO LADYBIRD ANT FLY BLUEBOTTLE EARWIG GRASSHOPPER CLEGG WASP BEETLE BEE CRICKET HORNET CATERPILLAR CHAFER SPIDER COCKROACH BUTTERFLY MOTH DRONE LOCUST CENTIPEDE MAYBUG SCORPION CICADA TARANTULA BULL Code name mm mm 7/2,06 3/3,35 7/2,21 3/3,66 7/2,59 7/2,79 7/3,10 7/3,40 7/3,66 7/3,78 7/3,91 7/4,17 7/4,39 19/2,67 7/4,90 7/5,36 19/3,25 19/3,53 19/3,78 19/3,99 19/4,22 19/4,65 19/5,00 37/3,58 19/5,36 37/3,78 37/4,09 37/4,27 37/4,65 37/5,23 61/4,25 mm² 14,19 16,13 16,13 19,35 22,58 25,81 32,26 38,71 45,16 48,39 51,61 58,06 64,52 64,52 80,64 96,77 96,77 112,90 129,00 145,20 161,30 193,50 225,80 225,80 258,10 258,10 290,30 322,60 387,10 483,90 527,87 6,18 7,24 6,63 7,91 7,77 8,37 9,30 10,20 10,98 11,34 11,73 12,51 13,17 13,35 14,70 16,08 16,25 17,65 18,90 19,95 21,10 23,25 25,00 25,06 26,80 26,46 28,63 29,89 32,55 36,61 38,25 Overall diameter Stranding and wire diameter Equival. copper area kg/km 64,00 72,70 73,70 86,80 101 117 145 174 202 216 231 262 291 293 362 434 435 513 588 655 733 890 1030 1030 1180 1150 1340 1460 1740 2200 2400 mm² Mass 23,33 26,44 26,85 31,56 36,88 42,80 52,83 63,55 73,65 78,55 84,05 95,60 105,95 106,38 132,00 157,95 157,95 185,95 213,22 237,57 265,75 322,66 373,06 372,44 428,72 415,22 486,11 529,84 628,34 794,87 865,36 Aluminium area MPa /C° x 10-6 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 Newton 4340 4340 4860 5130 6360 7250 8770 10400 12000 12700 13600 15400 17000 18200 21000 25100 26000 30300 34500 38300 42700 51500 59400 60600 68200 67200 78200 85000 100000 126000 139000 52400 50000 52400 60000 52400 52400 52400 52400 52400 52400 52400 52400 52400 49650 52400 52400 49650 49650 49650 49650 49650 49650 49650 48250 49650 48250 48250 48250 48250 48250 46200 Initial modulus of elasticity Ultimate tensile strength Coefficient of linear expansion 61000 69000 61000 69000 61000 61000 61000 61000 61000 61000 61000 61000 61000 59650 61000 61000 59650 59650 59650 59650 59650 59650 59650 58600 59650 58600 58600 58600 58600 58600 57570 MPa Final modulus of elasticity All Aluminium Conductor - AAC (British Standard Sizes) m 3000 3000 3000 3000 2500 2500 2500 2500 2500 2500 2000 1500 1500 2000 1000 1000 2000 2000 2000 1500 1500 1000 1000 1000 2000 1000 1000 1000 1000 1000 1000 A 139 154 152 172 185 203 231 259 284 296 308 334 356 358 408 456 457 506 551 589 632 713 779 779 849 833 918 967 1070 1230 1300 1,2271 1,0810 1,0662 0,9078 0,7763 0,6690 0,5419 0,4505 0,3887 0,3644 0,3406 0,2995 0,2702 0,2704 0,2169 0,1813 0,1825 0,1547 0,1349 0,1211 0,1083 0,0892 0,0771 0,0774 0,0671 0,0694 0,0593 0,0544 0,0459 0,0363 0,0334 Ω/km Standard drum length Current rating DC resistance at 20°C 11 ROSE LILY IRIS PANSY POPPY ASTER PHLOX OXLIP DAISY PEONY TULIP CANNA COSMOS ZINNIA DAHLIA ORCHID VIOLET PETUNIA ARBUTUS ANEMONE MAGNOLIA BLUEBELL MARIGOLD HAWTHORN NARCISSUS COLUMBINE CARNATION GLADIOLUS COREOPSIS Code name kg/km 58,00 73,00 92,10 116 147 185 233 294 371 419 470 554 665 699 775 891 1000 1050 1110 1220 1340 1440 1560 1670 1790 1900 2010 2110 2230 mm² 21,12 26,61 33,54 42,18 53,52 67,35 84,91 106,92 135,25 151,85 170,48 200,99 241,15 253,30 281,08 322,24 362,11 378,71 402,14 442,00 483,74 522,42 563,65 603,78 645,29 684,55 724,97 762,72 805,36 mm 5,88 6,60 7,41 8,31 9,36 10,50 11,79 13,23 14,88 15,95 16,90 18,35 20,10 20,60 21,70 23,31 24,71 25,27 26,04 27,30 28,56 29,68 30,87 31,95 33,03 34,02 35,01 35,91 36,90 mm 7/1,96 7/2,20 7/2,47 7/2,77 7/3,12 7/3,50 7/3,93 7/4,41 7/4,96 19/3,19 19/3,38 19/3,67 19/4,02 19/4,12 19/4,34 37/3,33 37/3,53 37/3,61 37/3,72 37/3,90 37/4,08 37/4,24 61/3,43 61/3,55 61/3,67 61/3,78 61/3,89 61/3,99 61/4,10 mm² Mass 13,30 16,77 21,15 26,67 33,62 42,41 53,50 67,43 85,01 95,59 107,21 126,69 152,01 159,38 177,40 202,70 228,01 239,00 253,39 278,71 304,09 329,29 354,72 380,02 405,41 437,72 456,01 481,42 506,71 Aluminium area Overall diameter Stranding and wire diameter Equival. copper area MPa /C° x 10-6 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 Newton 4020 4830 5860 7150 8870 11000 13700 17100 21600 25100 27900 32600 38900 40700 45100 52900 59000 61600 65200 71400 77800 83900 92200 98400 105000 111000 117000 123000 130000 52400 52400 52400 52400 52400 52400 52400 52400 52400 49650 49650 49650 49650 49650 49650 48250 48250 48250 48250 48250 48250 48250 46200 46200 46200 46200 46200 46200 46200 Initial modulus of elasticity Ultimate tensile strength Coefficient of linear expansion 61000 61000 61000 61000 61000 61000 61000 61000 61000 59650 59650 59650 59650 59650 59650 58600 58600 58600 58600 58600 58600 58600 57570 57570 57570 57570 57570 57570 57570 MPa Final modulus of elasticity m 5000 5000 5000 2000 2000 2000 2000 2000 2000 1500 2000 2000 2000 2000 2000 2000 2000 2000 2000 1500 1500 1000 1000 1000 1000 1000 1000 1000 1000 A 130 150 170 200 230 270 310 360 410 450 480 530 590 610 650 710 770 790 820 870 910 960 1000 1050 1100 1130 1170 1200 1240 Ω/km 1,3555 1,0759 0,8535 0,6787 0,5349 0,4251 0,3372 0,2678 0,2117 0,1894 0,1687 0,1431 0,1193 0,1136 0,1023 0,0895 0,0796 0,0761 0,0717 0,0652 0,0596 0,0552 0,0513 0,0479 0,0448 0,0422 0,0399 0,0379 0,0359 Standard drum length Current rating DC resistance at 20°C All Aluminium Conductor - AAC (Canadian Standard Sizes) 12 68 106 159 273 434 745 888 1145 1454 1891 2402 24,7 38,6 58,1 99,8 157,6 270,8 322,7 415,2 527,4 684,6 869,4 6,42 8,03 10,15 12,91 16,92 21,52 23,49 26,73 30,12 34,36 38,73 GEMINI JUPITER LEO LIBRA MARS MERCURY MOON NEPTUNE PLUTO SATURN TAURUS TRITON URANUS VENUS VIRGO Code name 4120 6120 8820 14600 23400 38800 46200 59900 75600 96600 122000 Newton Ultimate tensile strength Initial modulus of elasticity MPa 52400 52400 52400 52400 49650 49650 49650 48250 48250 46200 46200 Coefficient of linear expansion /C° x 10-6 23 23 23 23 23 23 23 23 23 23 23 61000 61000 61000 61000 59650 59650 59650 58600 58600 57570 57570 MPa Final modulus of elasticity mm² 16,84 27,83 34,36 49,48 77,31 111,33 124,04 157,62 209,85 261,54 336,69 408,65 506,04 673,72 1447,29 mm 5,25 6,75 7,50 9,00 11,25 13,50 14,25 16.25 18,75 21,00 23,75 26,25 29,25 36,75 49,50 mm 7/1,75 7/2,25 7/2,50 7/3,00 7/3,75 7/4,50 7/4,75 19/3,25 19/3,75 37/3,00 19/4,75 37/3,75 61/3,25 61/3,75 91/4,50 mm² 26,61 43,97 54,29 78,18 122,15 175,90 195,98 249,04 331,56 413,23 531,97 645,67 799,54 1064,48 2286,72 Aluminium area Overall diameter Stranding and wire diameter Equival. copper area 46 76 94 136 213 307 342 435 579 722 929 1128 1397 1859 3995 kg/km Mass Initial modulus of elasticity MPa 52400 52400 52400 52400 52400 52400 52400 49650 49650 48250 49650 48250 46200 46200 46200 Coefficient of linear expansion /C° x 10-6 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 Newton 3400 5010 5980 8260 12500 17800 19800 26000 34000 43700 53700 66200 83400 109000 232000 Ultimate tensile strength 61000 61000 61000 61000 61000 61000 61000 59650 59650 58600 59650 58600 57570 57570 57570 MPa Final modulus of elasticity m 5000 5000 5000 2000 2000 2000 2000 2000 2000 2000 2000 2000 1000 1000 1000 Current rating A 120 160 180 220 300 370 390 460 550 620 730 820 940 1130 1710 DC resistance at 20°C Ω/km 1,7003 1,0286 0,8332 0,5786 0,3703 0,2572 0,2308 0,1825 0,1371 0,1102 0,0854 0,0706 0,0571 0,0429 0,0200 Standard drum length m 3000 2500 2500 1500 2000 1500 1000 1000 1000 1000 1000 A 144 190 247 343 457 640 713 833 967 1130 1300 1,182 0,756 0,503 0,293 0,196 0,108 0,0909 0,0708 0,0558 0,0431 0,0339 Ω/km Standard drum length Current rating DC resistance at 20°C All Aluminium Conductors - AAC (Australian Standard Sizes) kg/km mm² mm mm 7/2,12 7/2,65 7/3,25 7/4,26 19/3,25 19/4,26 19/4,65 37/3,78 37/4,26 61/3,78 61/4,26 15,6 24,3 36,6 62,9 99,4 171,0 203,5 262,0 332,6 431,8 548,3 Mass mm² Aluminium area Overall diameter Stranding and wire diameter Equival. copper area * Standard British sizes † Standard Canadian sizes 25 39 58 100 * 158 271 * 323 * 415 * 527 † 685 * 869 Code name All Aluminium Conductors - AAC (South African Standard Sizes) AAAC All Aluminium Alloy Conductor 13 14 AGATE AMETHYST DIAMOND EMERALD GARNET JADE JASPER OPAL PEARL RUBY RUTILE SAPPHIRE SPINEL TOPAZ ZIRCON Code name mm² 16,84 27,83 34,36 49,48 77,31 111,3 124,0 157,6 209,8 261,5 336,7 408,7 506,0 673,7 1447,3 mm 5,25 6,75 7,50 9,00 11,30 13,5 14,3 16,3 18,8 21,0 23,8 26,3 29,3 33,8 49,5 mm 7/1,75 7/2,25 7/2,50 7/3,00 7/3,75 7/4,50 7/4,75 19/3,25 19/3,75 37/3,00 19/4,75 37/3,75 61/3,25 61/3,75 91/4,50 mm² 9,0 14,8 18,2 26,2 41,0 59,0 65,8 83,6 111,0 138,7 178,6 216,8 268,4 357,4 769,8 Aluminium area Overall diameter Stranding and wire diameter Equival. copper area 46 76 94 135 211 304 339 433 577 720 925 1125 1400 1863 4003 kg/km Mass Initial modulus of elasticity MPa 52400 52400 52400 52400 52400 52400 52400 49650 49650 48250 49650 48250 46200 46200 46200 /C° x 10-6 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 Newton 4724 7800 9630 13900 21700 31200 34800 44200 58800 73300 94400 114500 141800 189000 406000 Ultimate tensile strength Coefficient of linear expansion 61000 61000 61000 61000 61000 61000 61000 59650 59650 58600 59650 58600 57570 57570 57570 MPa Final modulus of elasticity Current rating A 106 147 167 209 276 346 371 430 513 588 689 776 889 1056 1630 DC resistance at 20°C Ω/km 1,952 1,18 0,958 0,665 0,426 0,296 0,265 0,210 0,158 0,127 0,0982 0,0811 0,0650 0,0490 0,0230 All Aluminium Alloy Conductors - AAAC (Australian Standard Sizes) 3000 3000 2500 2500 2000 1000 1000 2000 2000 2000 1000 2000 2000 2000 1000 m Standard drum length 15 ACACIA ALMOND CEDAR 35 FIR HAZEL PINE 70 WILLOW 80 90 OAK 100 MULBERRY ASH ELM POPLAR 225 SYCAMORE UPAS 350 YEW Code name mm mm 7/2,08 7/2,34 7/2,54 7/2,77 7/2,95 7/3,30 7/3,61 7/3,91 7/4,04 7/4,19 7/4,45 7/4,65 19/2,82 19/3,18 19/3,48 19/3,76 37/2,87 37/3,05 37/3,23 37/3,53 37/3,81 37/4,06 mm² 13 16 19 22 25 32 38 45 48 51 58 63 63 80 96 112 119 143 161 192 224 254 6,24 7,02 7,59 8,31 8,85 9,90 10,83 11,73 12,12 12,57 13,35 13,95 14,10 15,90 17,40 18,80 20,09 21,35 22,61 24,71 26,67 28,42 Overall diameter Stranding and wire diameter Equival. copper area kg/km 65 82 97 115 131 164 196 230 245 264 298 325 326 415 497 580 660 744 835 997 1162 1319 mm² Mass 23,79 30,10 35,47 42,18 47,84 59,87 71,65 84,05 89,73 96,52 108,9 118,9 118,7 150,9 180,7 210,9 239,4 270,3 303,2 362,1 421,8 479,0 Aluminium area 6690 8440 9960 11860 13430 16820 20200 23630 25200 27060 30400 33330 33330 42350 50690 59220 67350 75780 85000 101670 118430 134510 Newton Ultimate tensile strength Initial modulus of elasticity MPa 52500 52400 52400 52400 52400 52400 52400 52400 52400 52400 52400 52400 49650 49650 49650 49650 48250 48250 48250 48250 48250 48250 Coefficient of linear expansion /C° x 10-6 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 23 m 3000 2500 2500 2500 2500 2500 2500 2000 1500 1500 1000 1000 2000 2000 2000 2000 2000 2000 2000 2000 1500 1500 A 133 153 169 189 204 235 262 290 302 316 339 359 359 416 467 513 551 600 643 718 789 853 Ω/km 1,39 1,10 0,934 0,785 0692 0,553 0,462 0,394 0,369 0,343 0,306 0,279 0,280 0,221 0,184 0,158 0,139 0,123 0,110 0,0921 0,0791 0,0696 MPa 61000 61000 61000 61000 61000 61000 61000 61000 61000 61000 61000 61000 59650 59650 59650 59650 58600 58600 58600 58600 58600 58600 Standard drum length Current rating DC resistance at 20°C Final modulus of elasticity All Aluminium Alloy Conductors - AAAC (British Standard Sizes) 16 ALTON AMES AZUZA ANAHEIM AMHERST ALLIANCE BUTTE CANTON CAIRO DARIEN ELGIN FLINT GREELY Code name kg/km 68 107 171 215 272 342 436 549 650 780 910 1031 1293 mm² 24,71 39,19 62,44 78,55 99,30 125,09 115,86 200,0 236,4 283,7 331,0 374,5 469,6 mm 6,36 8,01 10,11 11,34 12,75 14,31 16,30 18,30 19,90 21,80 23,55 25,13 28,14 mm 7/2,12 7/2,67 7/3,37 7/3,78 7/4,25 7/4,77 19/3,26 19/3,66 19/3,98 19/4,36 19/4,71 37/3,59 37/4,02 mm² Mass 13,1 20,8 33,1 42 53 66 84 106 125 150 176 199 249 Aluminium area Overall diameter Stranding and wire diameter Equival. copper area 7850 12550 19900 24020 30290 38140 48800 59100 69700 83600 97650 108500 136000 Newton Ultimate tensile strength Initial modulus of elasticity MPa 52400 52400 52400 52400 52400 52400 49650 49650 49650 49650 49650 48250 48250 Coefficient of linear expansion /C° x 10-6 23 23 23 23 23 23 23 23 23 23 23 23 23 61000 61000 61000 61000 61000 61000 59650 59650 59650 59650 59650 58600 58600 MPa Final modulus of elasticity m 3000 2500 2500 2500 1000 1000 2000 2000 2000 1000 1000 2000 1500 A 147 196 262 302 349 403 468 541 599 671 739 799 918 Ω/km 1,14 0,714 0,448 0,356 0,283 0,224 0,177 0,140 0,119 0,099 0,0848 0,0746 0,0595 Standard drum length Current rating DC resistance at 20°C All Aluminium Alloy Conductors - AAAC (American Standard Sizes) Product Range Our Services are Wide but Specialised The Aberdare Group's product range and services are wide but specialised. Tried and tested and carrying South African Bureau of Standards (SABS) marks and complying with International Standards, we stand by our products. Impregnated Paper Cable • 1 kV - 33 kV • Fully impregnated, general purpose, heavy-duty or Drained • Copper or aluminium conductors • 1-5 core • Armoured or unarmoured MV XLPE-Insulated Cables • XLPE-insulated, 3,8/6,6 kV to 19/33 kV • Copper or aluminium conductors • 1-core or 3-core • Armoured or unarmoured Bells Cable • PVC-insulated, 600/1000 V • 1-7 core • Armoured or unarmoured • With or without enhanced fire performance Mains Cable • PVC or XLPE-insulated 600/1000 V and 1900/3300 V • 1-7 core • Standard or concentric lay • Armoured or unarmoured • With or without enhanced fire performance Electrodac Cable • Airdac CNE 600/1000 V with and without auxiliary cores • Airdac SNE 600/1000 V with and without auxiliary cores • Interdac III 1,9/3,3 kV • Airfield ligfhting 5 kV General Wires & Cable Insulated (GWCI) • Slipdac cable 600/1000 V • HQR high temperature cable 300/500 V • Panel/Cubicle cable 300/500 V • PVC cords 300/300 V and 300/500 V • Flexible PVC cable 450/750 V and 600/1000 V • PVI cable 450/750 V and 600/1000 V • Surfix 300/500 V • Flat wiring cable 300/500 V • Autocord 100 V • Illumination cable 300/500 V and 450/750 V • AudioRip cord 300/300 V General Wires and Conductors Bare • Copper, annealed, HD, tinned, Class 1, 2, 5 and 6 • Aluminium, hard drawn, Class 1 or 2 Aerial Bundled Conductors (ABC) • Supporting-core type 600/1000 V • Self-supporting type 600/1000 V • Service-connection type 600/1000 V • MV ABC cable 3,8/6,6 to 19/33 kV Elastomeric Cable • H05RR-F 300/500 V • H05RRN-F 300/500 V • H07RN-F 450/750 V • Trackless Mining 640/1100 V • Type 41 Mining 640/1100 V • Type 61A Reeling 640/1100 V • Type 61 B non-reeling 640/1100 V • Type 63 Reeling 1900/3300 V • MV Trailing 3,8/6,6 kV to 19/33 kV • Locomotive to 6 kV • Welding 100 V Silicone Cable • Multicore Cabtye 300/500 V • 1-core unbraided 180 ºC 300/500 V • 1-core braided 250 ºC 300/500 V PVC-Nitrile Cable • 1-core and sheathed 600/1000 V • Welding cable 100 V • Flexible Trailing cable 600/1000 V Overhead Conductor • Aluminium conductored steel reinforced (ACSR) • All aluminium conductor (AAC) • All aluminium alloy conductor (AAAC) • XLPE or PVC covered ACSR, AAC, AAAC Signalling & Control Multicore Cable • PVC-insulated • 7-37 core • Armoured or unarmoured • With or without added fire performance