Transformer Isolated Amplifier EG4-OTLK Output: Transistor Input I ... Input IV EEx ia IIC Sensor - Control circuit EEx ia IIC mech. contact with LB / SC Hazardous Area - 4-Channel - DC 24 V supply voltage - Lead breakage (LB) and short circuit (SC) monitoring may be disabled Chan. Chan. Chan. Chan. 1 2 3 4 Chan. Chan. Chan. Chan. 1 2 3 4 z2+ z4+ z6+ z8+ d2d4d6d8- - 1 active transistor output per channel, fault signal. - 2 transistor outputs per channel 1 passive transistor output: 100 mA 1 active transistor output: 10 mA The transformer isolated amplifier transmits digital signals from the hazardous area. Sensors per DIN 19234 (NAMUR) or mechanical contacts can serve as inputs. The control circuit can be monitored by lead breakage and short circuit monitoring. 1 kΩ z2+ z4+ z6+ z8+ 10 kΩ d2d4d6d8- * LB z2+ z4+ z6+ z8+ d2d4d6d8- b2 b4 b6 b8 2.1 ... 2.4 + LB SC + 4 Channel 3.1 1.1 ... 1.4 SC Safe Area - Reversible operating mode & Notes on connection assignments: Lead breakage monitoring (LB) d2, b2; d4, b4; d6, b6; d8, b8 Lead breadage monitoring can be disabled by bridging the above connections. If necessary, the unit can be supplied with the lead breakage monitoring feature already disabled with a factory installed jumper on the card. Operating mode z18; z22; z26; z30 Logic-1: no reversal of operating mode from input to output Logic-0: reversal of operating mode from input to output (see table of operating modes on page 25) If necessary, the operating mode can also be selected with a factory installed jumper on the card. =1 + - & U red yellow Chan. 1 Chan. 2 Chan. 3 Chan. 4 z18 z22 z26 z30 Operating Mode 6.1 ... 6.4 U (-) z20 z24 z28 z32 b18b22b26b30- Output I / IV VII / X d18+ d22+ d26+ d30+ Output II / V VIII / XI b14 d16 b16 z16 Output III / VI IX / XII Fault Signal d14 (L+) z14 (L-) Power Supply * Bridge for disabling lead breakage monitoring Fault signal outputs b14; d16; b16; z16 For short circuit or lead breakage (Indicator: LED red). The error signal outputs are combined by a circuit lead, so that only one connection is required for the fault evaluation of all channels on the card. If the evaluation of each individual channel is necessary, then the circuit lead must be breached at positions 6.1 ... 6.4 as shown (See side view of card). Front View Type A (dimensions see page 16) LED yellow: Electronic Output Chan. 2 LED red: Fault Signal Chan. 2 LED yellow: Electronic Output Chan. 4 LED yellow: Transistor Output Chan. 1 LED red: Fault Signal Chan. 1 LED yellow: Transistor Output Chan. 3 LED red: Fault Signal Chan. 3 Issue Date 20.02.02 LED red: Fault Signal Chan. 4 Subject to reasonable modifications due to technical advances. 80 Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group · Tel.: Germany (6 21) 7 76-22 22 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91 · Internet http://www.pepperl-fuchs.com Transformer Isolated Amplifier EG4-OTLK Output: Transistor Technical data Power supply Nominal voltage Ripple Nominal current DC 20.4 V ... 27.6 V ≤ 10 % ≤ 120 mA Inputs (intrinsically safe) Input I : Input II : Input III : Input IV : Nominal circuit values Open circuit voltage / short circuit current Switch point / switch hysteresis Input pulse length / pulse interval Lead monitoring Connections z2+, d2Connections z4+, d4Connections z6+, d6Connections z8+, d8per DIN 19 234 with respect to NAMUR about DC 8 V / about 8 mA 1.2 mA ... 2.1 mA / about 0.2 mA ≥ 0.5 ms / ≥ 0.5 ms Breakage J < 0.1 mA short circuit J > 6 mA Connections d14 (L+), z14 (L-) Certificate of Conformity Peak Values Max. voltage U0 Max. current I0 Max. power P0 Allowable circuit values Ignition protection method, category Explosion group Max. external capacitance Max. external inductance PTB Nr. Ex-81/2065X other certifications see www.pepperl-fuchs.com 12.7 V 21 mA 66 mW [EEx ia] IIB 1.1 µF 5 mH Input (not intrinsically safe) Signal level Logic-1 Signal level Logic-0 DC 15 V ... 30 V DC 0 V ... 5 V or B-contact input Outputs (not intrinsically safe) Output I, IV, VII, X : Nominal current Signal level Logic-1 / Logic-0 Output II, V, VIII, VI : Nominal current Transistor output, active Connections z20, z24, z28, z32 10 mA, short circuit protection (L+) -3 V / cut off output (leakage current J ≤ 10 µA) Transistor output, passive Connections b18-; d22+, b22-; d26+, b26-; d30+, b30100 mA, short circuit protection Transfer characteristics Switch frequency 1 kHz Galvanic isolation Output I ... XII from each other Output I ... XII from the power supply Input I ... IV from output I ... XII Input I ... IV from power supply Safe Safe Safe Safe Conformity to standard Input Climatic conditions per DIN 19234 (NAMUR) per DIN IEC 721 Ambient temperature Connection method Coding Weight -25 °C ... +70 °C (248 K ... 343 K) 48-pin plug connector per DIN 41 612, Series 2, Type F; z, b and d provided a3 / c7 about 100 g / IIC / 0.37 µF / 2 mH [EEx ib] IIB 3.9 µF 260 mH / IIC / 0.8 µF / 70 mH Connections z18, z22, z26, z30 per DIN VDE 0106, per DIN VDE 0106, isolation per EN 50 isolation per EN 50 design isolation voltage 50 Veff design isolation voltage 50 Veff 020, voltage peak value 375 V 020, voltage peak value 375 V Issue Date 20.02.02 isolation isolation galvanic galvanic Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group · Tel.: Germany (6 21) 7 76-22 22 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91 · Internet http://www.pepperl-fuchs.com 81 Transformer Isolated Amplifier EG4-OTLK Output: Transistor EExInput module V1.1 Plug Connector per DIN 41 612 1.4 2.1 2.2 EExInput module V1.2 1.3 3.1 1.2 EExInput module V1.3 1.1 EExInput module V1.4 2.3 2.4 Side View 6.1 6.2 6.3 6.4 Programming facilities on the card Jumpers Plug-in design: 1.1 (open) 1.2 (open) 1.3 (open) 1.4 (open) 2.1 (open) 2.2 (open) 2.3 (open) 2.4 (open) If link 3.1 is closed, Reverse operating mode of channel 1 Reverse operating mode of channel 2 Reverse operating mode of channel 3 Reverse operating mode of channel 4 Lead breakage monitoring channel 1: active Lead breakage monitoring channel 2: active Lead breakage monitoring channel 3: active Lead breakage monitoring channel 4: active short circuit and lead breakage monitoring for all channels are cut off. 6.1, 6.2, 6.3, 6.4 Separation of the individual monitoring outputs Delivery status Jumpers 1.1 to 3.1: open Issue Date 01.08.96 Breach points Subject to reasonable modifications due to technical advances. 82 Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group · Tel.: Germany (6 21) 7 76-22 22 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91 · Internet http://www.pepperl-fuchs.com