TW_EP1070.book Page 1 Wednesday, January 19, 2005 10:49 AM ø22mm TW Series Control Units TW_EP1070.book Page 2 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Control Units (Selection Guides) Function Category Flush Extended Pushbutton Extended w/Full Shroud Momentary/Maintained ø29mm Mushroom ø40mm Mushroom ABW1 AOW1 8 ABW2 AOW2 8 ABFW2 AOFW2 8 ABW3 AOW3 8 ABW4 AOW4 9 Shape Type Page Function Category Pushbutton ø40mm Mushroom w/Full Shroud Momentary ø29mm Mushroom ø40mm Mushroom ø40mm Mushroom ø29mm Mushroom Pushlock Turn Reset Pushlock Turn Reset Push Turn Lock Pushlock Key Reset ABGW4 9 AVW3 9 AVW4 9 AJW4 9 AXW3 9 Shape Type Page Function Category ø40mm Mushroom Pushlock Key Reset Pushbutton ø40mm Mushroom Square Flush Square Extended Push Pull Momentary/Maintained Shape Type AXW4 AYW4 Page 10 10 Function Category ABQW1 AOQW1 10 Pilot Light Flush (Non-marking/Marking) Dome Square Flush (Marking) APW2 UPQW1B 11 11 Shape Type Page 2 APW1 APW1B 11 ABQW2 AOQW2 10 TW_EP1070.book Page 3 Wednesday, January 19, 2005 10:49 AM TW Series Control Units (Selection Guides) ø22 Function Category Illuminated Pushbutton (LED/Incandescent) Extended Extended w/Full Shroud Square Extended ø29mm Mushroom (Non-marking/Marking) (Non-marking/Marking) (Marking) Pushlock Turn Reset ø40mm Mushroom Pushlock Turn Reset Shape Type Page Function Category ALW2, ALW2B, AOLW2, AOLW2B 13, 14 ALFW2, AOLFW2 ALFW2B, AOLFW2B 15, 16 ALQW2B AOLQW2B 17 AVLW3 AVLW3B 18 AVLW4 AVLW4B 19 Illuminated Pushbutton (Incandescent) ø29mm Mushroom ø40mm Push-Pull (Non-marking/Marking) Shape Type Page ALW3, ALW3B, AOLW3, AOLW3B 18 Knob Lever Key Illuminated Selector Switch (LED/Incandescent) Knob ASW 22 ASW∗L 23 ASW∗K 24 ASLW 25, 26 Function Category AYLW4 AYLW4B 19 Selector Switch Shape Type Page 3 TW_EP1070.book Page 4 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Control Units General-purpose control units for various applications Heavy-duty type for high-level protection against harsh environment Low Voltage Directive EMC Directive • Highly reliable HW contact blocks are used. • Degree of protection: IP65 (IEC 60529) • UL and CSA approved, EN compliant Safety Standards File No. or Organization UL UL Listing File No. E68961 CSA File No. LR21451 EN EN60947-1 EN60947-5-1 TÜV Rheinland Specifications and Ratings Contact Ratings Contact Block Rated Insulation Voltage Rated Continuous Current Contact Ratings by Utilization Category IEC 60947-5-1 600V 10A AC-15 (A600) DC-13 (P600) Characteristics • Contact Ratings by Utilization Category Operational Voltage AC Operational 50/60 Hz Current DC AC-12 AC-15 DC-12 DC-13 Control of resistive loads and solid state loads Control of electromagnetic loads (> 72 VA) Control of resistive loads and solid state loads Control of electromagnets 24V 10A 10A 8A 4A 48V — — 4A 2A 50V 10A 7A — — 110V 10A 5A 2.2A 1.1A 220V 6A 3A 1.1A 0.6A 440V 2A 1A — — Minimum applicable load: 3V AC/DC, 5 mA (applicable range may vary with operating conditions and load types) For the control units listed below, the rated current (load switching current) is reduced to a half of the rated operational current of the contact block. The rated insulation voltage (600V) and the rated thermal current (10A) remain unchanged. • Selector switches and illuminated selector switches with contact code 2S, 3S, 4S, 2R, or 4R. HW-C (Contact Block) • M3.5 terminal screw 2-way wiring possible • Snap-fit groove • Double-break rolling action silver contacts with raked surface • Fitting groove • Alkali-resistant 66 nylon housing • Contact Block Types • Push rod Color-coded for different contacts Contact NO NC NO (early make) NC (late break) Housing Blue Purple red Blue Purple red Push Rod Green Red Black White • Snap-fit latch A maximum of four contact blocks in two layers can mount on the operator. Incandescent Lamp Ratings (LS Type) Type No. Lamp Base Rated Voltage Wattage Voltage Marking LS-6 LS-8 LS-2 BA9S/13 6V AC/DC 12V AC/DC 18V AC/DC 1W (6.3V) 1W (18V) 1W (24V) Die stamped on the base Approx. 1,000 hours minimum Life (reference value) (mean value when used on the rated voltage) 4 LS-3 24V AC/DC 1W (30V) TW_EP1070.book Page 5 Wednesday, January 19, 2005 10:49 AM TW Series Control Units ø22 LED Lamp Ratings (LSTD Type) LSTD-6➁ LSTD-1➁ LSTD-2➁ BA9S/13 6V AC/DC 12V AC/DC 24V AC/DC 6V AC/DC ±10% 12V AC/DC ±10% 24V AC/DC ±10% A, R, W, Y: 17 mA, G, PW, S: 8 mA 11 mA 11 mA A, R, W, Y: 14 mA, G, PW, S: 5.5 mA 10 mA 10 mA A (amber), G (green), PW (pure white), R (red), S (blue), W (white), Y (yellow) Same as illumination color Die stamped on the base Approx. 50,000 hours (The luminance reduces to 50% the initial intensity when used on complete DC.) A, R, W, Y Type No. Lamp Base Rated Voltage Voltage Range AC DC Current Draw Color Code ➁ Lamp Base Color Voltage Marking Life (reference value) Internal Circuit G, PW, S LED Chip Protection Diode Zener Diode Specifications Operating Temperature Storage Temperature Operating Humidity Contact Resistance Insulation Resistance Dielectric Strength Vibration Resistance Shock Resistance Mechanical Life (minimum operations) Electrical Life (minimum operations) –25 to +50°C (no freezing) –40 to +80°C 45 to 85% RH (no condensation) 50 mΩ maximum (initial value) 100 MΩ minimum (500V DC megger) Between live and dead metal parts: 2,500V AC, 1 minute (Full voltage type illuminated units: 2,000V AC, 1 minute) Operating extremes: 5 to 55 Hz, amplitude 0.5 mm Damage limits: 1,000 m/s2 Operating extremes: 100 m/s2 Pushbuttons, Illuminated pushbuttons Momentary: 5,000,000 Others: 500,000 Selector switches: 500,000 Illuminated selector switches: 500,000 Pushbuttons: 500,000 (switching frequency 1,800 operations/h, duty ratio 40%) Illuminated pushbuttons: 500,000 (switching frequency 1,800 operations/h, duty ratio 40%) Selector switches: 500,000 (switching frequency 1,200 operations/h, duty ratio 40%) Mounting Hole Layout R0.8 max. ø22 50 +0 . 0 4 (45 min.) .3 +0.2 0 (Note 1) 24.1 +0.4 0 3.2 30 (Note 2) Note 1: The 3.2 mm recess is for preventing rotation and is not necessary when the nameplate or anti-rotation ring is not used. Note 2: The minimum mounting centers are applicable to switches with one layer of contact blocks (two contact blocks). When two layers of contact blocks are mounted, determine the minimum mounting centers in consideration of convenience for wiring. • ø40mm mushroom: 40 mm minimum • 2-position, 3-position lever type selector switch: 39 mm minimum • 4-position, 5-position lever type selector switch: 50 mm minimum Degree of Protection Type No. A∗∗∗∗ Unit NEMA ICS 6-110 IEC 60529 Pushbuttons, pilot lights, illuminated pushbutons, and selector switches Type 1, 2, 3, 3R, (3S), 4, 5, 12,13 IP65 Illuminated selector switches, key pushbuttons, key reset pushbuttons, and key selector switches Type 1, 2, 3R, 5, 12, 13 IP54 Note: (3S) of NEMA ICS 6-110 applies to the pilot lights with round lens. 5 TW_EP1070.book Page 6 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Control Units (Ordering Information) Ordering Information • Specify an operator or lens color code in the Type No. • Full voltage type illuminated units are not supplied with a lamp. Order LED or incandescent lamps separately. Transformer and DC-DC converter type illuminated units contain an LED or incandescent lamp. Rated Voltage 100/110V AC 200/220V AC 110V DC LED Lamp LSTD-6➁ LSTD-6➁ LSTD-6➁ • When a terminal cover is required, order an applicable terminal cover referring to page 30. Incandescent LS-6 LS-6 LS-6 • All standard units are UL, CSA, EN, and TÜV approved. The Type No. development charts shown below can be used to specify control units other than those listed on the following pages. Gold-plated silver contacts are also available. Pushbuttons Illuminated Pushbuttons ABW1 11 R - MAU ALFW2 116 13 D R - MAU Optional contact MAU: Gold-plated silver contact Button color code Contact arrangement code 10: 1NO 01: 1NC 11: 1NO-1NC 20: 2NO 02: 2NC 21: 2NO-1NC 12: 1NO-2NC 30: 3NO 03: 3NC 31: 3NO-1NC 22: 2NO-2NC 13: 1NO-3NC 40: 4NO 04: 4NC Note: • Push-pull type AYW4 can have a maximum of two contact blocks. Pilot Lights APW2 116 D R Lens color code Lamp type D: LED (Transformer type only) (blank): Incandescent Operating voltage code 99: Full voltage 16: Transformer (100/110V AC) 116: Transformer (115V AC) 126: Transformer (120V AC) 26: Transformer (200/220V AC) 236: Transformer (230V AC) 246: Transformer (240V AC) 386: Transformer (380V AC) 46: Transformer (400/440V AC) 486: Transformer (480V AC) 16D: DC-DC converter (110V DC) Note: • Full voltage type is not supplied with a lamp. • Transformer and DC-DC converter types contain an LED lamp (LSTD-6➁) or incandescent lamp (LS-6). 6 Optional contact MAU: Gold-plated silver contact Lens color code Lamp type D: LED (Transformer type only) (blank): Incandescent Contact arrangement code 10: 1NO 01: 1NC 11: 1NO-1NC 20: 2NO 02: 2NC 21: 2NO-1NC 12: 1NO-2NC 30: 3NO 03: 3NC 31: 3NO-1NC 22: 2NO-2NC 13: 1NO-3NC 40: 4NO 04: 4NC Operating voltage code 99: Full voltage 16: Transformer (100/110V AC) 116: Transformer (115V AC) 126: Transformer (120V AC) 26: Transformer (200/220V AC) 236: Transformer (230V AC) 246: Transformer (240V AC) 386: Transformer (380V AC) 46: Transformer (400/440V AC) 486: Transformer (480V AC) 16∗D: DC-DC converter (110V DC) Note: • Push-pull type AYLW4 can have a maximum of two contact blocks. • Transformer type and DC-DC converter type cannot have an odd number of contact blocks, such as 1NO, 1NC, 3NO, 2NO-1NC, 1NO-2NC, and 3NC. TW_Spec-Ordering Page 7 Monday, January 24, 2005 1:28 PM TW Series Control Units (Ordering Information) ø22 Selector Switch Illuminated Selector Switch ASW 2 L 11 - MAU ASLW 2 16 22 D R - MAU Optional contact MAU: Gold-plated silver contact Contact arrangement code Operator type (blank): Knob L: Lever Number of positions Note: • See pages 26 to 28 for contact arrangement codes. Key Selector Switch ASW 2 K 20 B - MAU Optional contact MAU: Gold-plated silver contact Key removable position code 2-position • Maintained (blank): Removable in all positions B: Removable in left only C: Removable in right only • Spring return from right (blank): Removable in left only • Spring return from left (blank): Removable in right only 3-position • Maintained (blank): Removable in all positions B: Removable in left and center C: Removable in right and center D: Removable in center only E: Removable in right and left G: Removable in left only H: Removable in right only • Spring return from right (blank): Removable in left and center D: Removable in center only G: Removable in left only • Spring return from left (blank): Removable in right and center D: Removable in center only H: Removable in right only • Spring return two-way (blank): Removable in center only Contact arrangement code Number of positions Optional contact MAU: Gold-plated silver contact Lens color code Lamp type D: LED (Transformer type only) (blank): Incandescent Contact arrangement code Operating voltage code 99: Full voltage 16: Transformer (100/110V AC) 156: Transformer (115V AC) 136: Transformer (120V AC) 26: Transformer (200/220V AC) 236: Transformer (230V AC) 256: Transformer (240V AC) 386: Transformer (380V AC) 46: Transformer (400/440V AC) 486: Transformer (480V AC) Number of positions Note: • Full voltage type is not supplied with a lamp. • Transformer type contains an LED lamp (LSTD-6➁) or incandescent lamp (LS-6). • See pages 27 to 29 for contact arrangement codes. Note: • See pages 27 to 29 for contact arrangement codes. • The key cannot be removed in the return position. 7 TW_EP1070.book Page 8 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Pushbuttons Flush / Extended / Extended w/Full Shroud / Mushroom Types Extended with Full Shroud ABFW2 AOFW2 Momentary Maintained ø29mm Mushroom ABW3 AOW3 Momentary Maintained 37 30 Panel Thickness 1 to 6 Specify a button color code in place of ➀ in the Type No. B: G: R: S: W: Y: black green red blue white yellow 37 M3.5 Terminal Screws • Specify a button color code in place of ➀ in the Type No. • Round bezel and shroud (metal): Mat aluminum color • Pushbuttons with one or three contact blocks contain a dummy block. • Other contact arrangements and gold-plated silver contacts are also available. See page 6. 8 ø29 48.5 (1-2 blocks) 13 68.5 (3-4 blocks) 48.5 (1-2 blocks) 13 30 68.5 (3-4 blocks) 19 M3.5 Terminal Screws Panel Thickness 1 to 6 37 Maintained Panel Thickness 1 to 6 48.5 (1-2 blocks) 19.5 30 68.5 (3-4 blocks) M3.5 Terminal Screws Panel Thickness 1 to 6 48.5 (1-2 block) 68.5 (3-4 blocks) 37 Momentary M3.5 Terminal Screws ø29 Extended ABW2 AOW2 Dimensions (mm) ø29 Maintained ABW110➀ ABW101➀ ABW111➀ ABW120➀ ABW102➀ ABW122➀ AOW110➀ AOW101➀ AOW111➀ AOW120➀ AOW102➀ AOW122➀ ABW210➀ ABW201➀ ABW211➀ ABW220➀ ABW202➀ ABW222➀ AOW210➀ AOW201➀ AOW211➀ AOW220➀ AOW202➀ AOW222➀ ABFW210➀ ABFW201➀ ABFW211➀ ABFW220➀ ABFW202➀ ABFW222➀ AOFW210➀ AOFW201➀ AOFW211➀ AOFW220➀ AOFW202➀ AOFW222➀ ABW310➀ ABW301➀ ABW311➀ ABW320➀ ABW302➀ ABW322➀ AOW310➀ AOW301➀ AOW311➀ AOW320➀ AOW302➀ AOW322➀ ➀ Button Color Code ø29 Momentary 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC Type No. ø24 Flush ABW1 AOW1 Contact ø24 Operation Type ø24 Shape 13 22.5 30 TW_EP1070.book Page 9 Wednesday, January 19, 2005 10:49 AM TW Series Pushbuttons ø22 Mushroom / Pushlock Turn Reset / Push Turn Lock / Pushlock Key Reset Types ABGW411➀ 2NO ABGW420➀ ø29mm Pushlock Turn Reset AVW3 (Note) 2NC ABGW402➀ 2NO-2NC ABGW422➀ 1NO AVW310➀ 1NC AVW301➀ 1NO-1NC AVW311➀ 2NO AVW320➀ 2NC AVW302➀ 2NO-2NC ø40mm Pushlock Turn Reset AVW4 (Note) ø40mm Push Turn Lock AJW4 1NO AVW410➀ 1NC AVW401➀ 1NO-1NC AVW411➀ 2NO AVW420➀ 2NC AVW402➀ 2NO-2NC AVW422➀ 1NO AJW410➀ 1NC AJW401➀ 1NO-1NC AJW411➀ 2NO AJW420➀ 2NC AJW402➀ 2NO-2NC AJW422➀ 1NO AXW310R 1NC AXW301R 1NO-1NC AXW311R 2NO AXW320R 2NC AXW302R 2NO-2NC AXW322R 37 ø40 Panel Thickness 1 to 6 48.5 (1-2 blocks) 68.5 (3-4 blocks) 30 23 M3.5 Terminal Screws Panel Thickness 1 to 6 Reset Angle 75° 48.5 (1-2 blocks) 13 30 22.5 68.5 (3-4 blocks) R: red Y: yellow M3.5 Terminal Screws Panel Thickness 1 to 6 Reset Angle 75° 48.5 (1-2 blocks) 13 68.5 (3-4 blocks) M3.5 Terminal Screws B: G: R: Y: 30 22.5 Panel Thickness 1 to 6 Reset Angle 75° black green red yellow LO SH CK ø29mm Pushlock Key Reset AXW3 (Note) AVW322➀ M3.5 Terminal Screw 37 1NO-1NC Momentary black green red blue white yellow 30 22.5 37 ABGW401➀ B: G: R: S: W: Y: 48.5 (1-2 blocks) 13 68.5 (3-4 blocks) 37 1NC Specify a button color code in place of ➀ in the Type No. 37 ABGW410➀ Panel Thickness 1 to 6 48.5 (1-2 blocks) 13 68.5 (3-4 blocks) M3.5 Terminal Screws 30 22.5 Panel Thickness Reset 1 to 6 (unlock) Red only 45 ° 37 1NO M3.5 Terminal Screws PU ø40mm Mushroom w/Full Shroud ABGW4 Dimensions (mm) ø29 Maintained ABW410➀ ABW401➀ ABW411➀ ABW420➀ ABW402➀ ABW422➀ AOW410➀ AOW401➀ AOW411➀ AOW420➀ AOW402➀ AOW422➀ ➀ Button Color Code ø46 Momentary 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC Type No. ø29 ø40mm Mushroom ABW4 AOW4 Contact ø40 Operation Type ø40 Shape 13 48.5 (1-2 blocks) 68.5 (3-4 blocks) 25 47 30 • Specify a button color code in place of ➀ in the Type No. • Round bezel (metal): Mat aluminum color • Pushbuttons with one or three contact blocks contain a dummy block. • Other contact arrangements and gold-plated silver contacts are also available. See page 6. Note: AVW3, AVW4, and AXW3 pushbuttons cannot be used as emergency stop switches. When emergency stop switches are required, use XW or HW series pushbuttons (ISO 13850 and IEC 60947-5-5 compliant). 9 TW_EP1070.book Page 10 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Pushbuttons Pushlock Key Reset / Push-Pull / Square Flush / Square Extended Type No. 1NO AXW410R 1NC AXW401R 1NO-1NC AXW411R 2NO AXW420R 2NC AXW402R ➀ Button Color Code Dimensions (mm) M3.5 Terminal Screws Panel Thickness 1 to 6 Reset (unlock) Red only 45 ° 37 Contact ø40 Operation Type ø40mm Mushroom Push Lock Key Reset AXW4 Shape 13 48.5 (1-2 blocks) 25 68.5 (3-4 blocks) 2NO AYW420➀ 2NC Square Flush ABQW1 AOQW1 Momentary Maintained Square Extended ABQW2 AOQW2 Momentary Maintained 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC 13 48.5 (1-2 blocks) 68.5 (3-4 blocks) AYW402➀ ABQW110➀ ABQW101➀ ABQW111➀ ABQW120➀ ABQW102➀ ABQW122➀ AOQW110➀ AOQW101➀ AOQW111➀ AOQW120➀ AOQW102➀ AOQW122➀ ABQW210➀ ABQW201➀ ABQW211➀ ABQW220➀ ABQW202➀ ABQW222➀ AOQW210➀ AOQW201➀ AOQW211➀ AOQW220➀ AOQW202➀ AOQW222➀ M3.5 Terminal Screws B: G: R: S: W: Y: black green red blue white yellow • Specify a button color code in place of ➀ in the Type No. • Round bezel (metal): Mat aluminum color • Square bezel (plastic): Black • Pushbuttons with one or three contact blocks contain a dummy block. • Other contact arrangements and gold-plated silver contacts are also available. See page 6. • Contact Statuses of Push-Pull Switch Contact ø40mm Mushroom Push-Pull Switch Push Pull 1NO 1NC 1NO-1NC 2NO 2NC • Note: Push-pull switch can have a maximum of two contact blocks. 10 37 AYW411➀ 25 30 30.5 Panel Thickness 1 to 6 37 1NO-1NC 48.5 (1-2 blocks) 13 30 68.5 (3-4 blocks) M3.5 Terminal Screws Panel Thickness 1 to 6 37 AYW401➀ Panel Thickness 1 to 6 ø40 1NC M3.5 Terminal Screws 25 AYW410➀ 30 1NO ø40mm Mushroom Push-Pull AYW4 30 47 30 AXW422R 25 2NO-2NC 48.5 (1-2 blocks) 13 68.5 (3-4 blocks) 20 30 TW_EP1070.book Page 11 Wednesday, January 19, 2005 10:49 AM TW Series Pilot Lights ø22 Round Flush / Dome / Square Flush Types Shape Round Flush APW1 Lamp Input Type Without Lamp Full Voltage APW199➁ Transformer APW1➂D➁ DC-DC Converter∗ APW11DD➁ LED Incandescent Round Flush (Marking) APW1B Transformer Without Lamp Full Voltage APW1➂➁ APW1B99➁ Transformer APW1B➂D➁ DC-DC Converter∗ APW1B16DD➁ LED Incandescent Dome APW2 Transformer Without Lamp Full Voltage APW1B➂➁ APW299➁ Transformer APW2➂D➁ DC-DC Converter∗ APW216DD➁ LED Incandescent Square Flush (Marking) APQW1B Transformer Without Lamp Full Voltage APW2➂➁ APQW1B99➁ Transformer APQW1B➂D➁ DC-DC Converter∗ APQW1B16DD➁ LED Incandescent Transformer ➁ Lens/LED Color Code Type No. APQW1B➂➁ A: G: PW: R: S: W: Y: amber green pure white red blue white yellow A: G: R: S: W: amber green red blue white A: G: PW: R: S: W: Y: amber green pure white red blue white yellow A: G: R: S: W: amber green red blue white A: G: PW: R: S: W: Y: amber green pure white red blue white yellow A: G: R: S: W: amber green red blue white A: G: PW: R: S: W: Y: amber green pure white red blue white yellow A: G: R: S: W: amber green red blue white ➂ Operating Voltage Code Specify an operating voltage code in place of ➂ in the Type No. 16: 116: 126: 26: 236: 246: 386: 46: 486: 100/110V AC 115 AC 120V AC 200/220V AC 230V AC 240V AC 380V AC 400/440V AC 480V AC • Specify a lens/LED color code in place of ➁ in the Type No. • The white (W) lens of APW1B and APQW1B types is a combination of clear lens and white marking plate. • Specify an operating voltage code in place of ➂ in the Type No. • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36. • LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). • Round bezel (metal): Mat aluminum color • Square bezel (plastic): Black ∗ DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). 11 TW_PL Page 12 Wednesday, January 19, 2005 1:37 PM ø22 TW Series Pilot Lights Dimensions • Round Flush APW1 Transformer, DC-DC Converter 30 28.5 • Round Flush Marking Type APW1B Transformer, DC-DC Converter ø24 37 13 30 28.5 Marking plate: ø15.5 mm 13 30 17 66.5 Marking plate: ø15.5 mm • Dome APW2 Transformer, DC-DC Converter 30 28.5 25 66.5 13 30 Marking plate: 28.5 22 mm • Arrows indicate access directions for wiring. TOP M3.5 M3.5 X1 X1 X2 X2 Full Voltage Type 37 Panel Thickness 1 to 6 Transformer Type DC-DC Converter Type 66.5 13 37 37 30 25 M3.5 Terminal Screw Terminal Wiring (Bottom View) TOP 30 25 • Square Flush Marking Type APQW1B Transformer, DC-DC Converter Panel Thickness 1 to 6 16 13 30 • Square Flush Marking Type APQW1B Full Voltage 28.5 ø23.6 37 13 25 28.5 Panel Thickness 1 to 6 M3.5 Terminal Screw ø29 ø23.6 Panel Thickness 1 to 6 ø29 • Dome APW2 Full Voltage 12 Panel Thickness 1 to 6 M3.5 Terminal Screw ø29 ø24 Panel Thickness 1 to 6 17 30 17 37 • Round Flush Marking Type APW1B Full Voltage 28.5 13 66.5 17 37 ø24 37 13 ø29 28.5 Panel Thickness 1 to 6 M3.5 Terminal Screw ø29 ø24 Panel Thickness 1 to 6 ø29 • Round Flush APW1 Full Voltage 30 16 Marking plate: 22 mm All dimensions in mm. TW_EP1070.book Page 13 Wednesday, January 19, 2005 10:49 AM TW Series Illuminated Pushbuttons ø22 . Round Extended Illuminated Pushbuttons Shape Round Extended ALW2 AOLW2 Operation Type Lamp Without Lamp Input Type Full Voltage Transformer Momentary LED DC-DC Converter∗ Incandescent Transformer Without Lamp Full Voltage Transformer Maintained LED DC-DC Converter∗ Incandescent Transformer Contact 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC Type No. ALW29911➁ ALW29920➁ ALW29922➁ ALW2➂11D➁ ALW2➂20D➁ ALW2➂22D➁ ALW21611DD➁ ALW21620DD➁ ALW21622DD➁ ALW2➂11➁ ALW2➂20➁ ALW2➂22➁ AOLW29911➁ AOLW29920➁ AOLW29922➁ AOLW2➂11D➁ AOLW2➂20D➁ AOLW2➂22D➁ AOLW21611DD➁ AOLW21620DD➁ AOLW21622DD➁ AOLW2➂11➁ AOLW2➂20➁ AOLW2➂22➁ • Color Code and Operating Voltage Code LED Illuminated Type ➁ Lens/LED Color Code Specify a lens/LED color code in place of ➁ in the Type No. A: amber G: green PW: pure white R: red S: blue W: white Y: yellow • • • ∗ Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens Color Code Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber 116: Transformer (115V AC) G: green 126: Transformer (120V AC) R: red 26: Transformer (200/220V AC) S: blue 236: Transformer (230V AC) W: white 246: Transformer (240V AC) 386: Transformer (380V AC) 46: Transformer (400/440V AC) 486: Transformer (480V AC) Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36. LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). 13 TW_EP1070.book Page 14 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Illuminated Pushbuttons Round Extended Illuminated Pushbuttons (Marking Type) Shape Round Extended (Marking) ALW2B AOLW2B Operation Type Lamp Without Lamp Input Type Full Voltage Transformer Momentary LED DC-DC Converter∗ Incandescent Transformer Without Lamp Full Voltage Transformer Maintained LED DC-DC Converter∗ Incandescent Transformer Contact 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC Type No. ALW2B9911➁ ALW2B9920➁ ALW2B9922➁ ALW2B➂11D➁ ALW2B➂20D➁ ALW2B➂22D➁ ALW2B1611DD➁ ALW2B1620DD➁ ALW2B1622DD➁ ALW2B➂11➁ ALW2B➂20➁ ALW2B➂22➁ AOLW2B9911➁ AOLW2B9920➁ AOLW2B9922➁ AOLW2B➂11D➁ AOLW2B➂20D➁ AOLW2B➂22D➁ AOLW2B1611DD➁ AOLW2B1620DD➁ AOLW2B1622DD➁ AOLW2B➂11➁ AOLW2B➂20➁ AOLW2B➂22➁ • Color Code and Operating Voltage Code LED Illuminated Type ➁ Lens/LED Color Code Specify a lens/LED color code in place of ➁ in the Type No. A: amber G: green PW: pure white R: red S: blue W: white Y: yellow • • • ∗ Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens Color Code Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber 116: Transformer (115V AC) G: green 126: Transformer (120V AC) R: red 26: Transformer (200/220V AC) S: blue 236: Transformer (230V AC) W: white 246: Transformer (240V AC) 386: Transformer (380V AC) 46: Transformer (400/440V AC) 486: Transformer (480V AC) Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36. LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). 14 TW_EP1070.book Page 15 Wednesday, January 19, 2005 10:49 AM TW Series Illuminated Pushbuttons ø22 Round Extended with Full Shroud Illuminated Pushbuttons Shape Round Extended With Full Shroud ALFW2 AOLFW2 Operation Type Lamp Without Lamp Input Type Full Voltage Transformer Momentary LED DC-DC Converter∗ Incandescent Transformer Without Lamp Full Voltage Transformer Maintained LED DC-DC Converter∗ Incandescent Transformer Contact 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC Type No. ALFW29911➁ ALFW29920➁ ALFW29922➁ ALFW2➂11D➁ ALFW2➂20D➁ ALFW2➂22D➁ ALFW21611DD➁ ALFW21620DD➁ ALFW21622DD➁ ALFW2➂11➁ ALFW2➂20➁ ALFW2➂22➁ AOLFW29911➁ AOLFW29920➁ AOLFW29922➁ AOLFW2➂11D➁ AOLFW2➂20D➁ AOLFW2➂22D➁ AOLFW21611DD➁ AOLFW21620DD➁ AOLFW21622DD➁ AOLFW2➂11➁ AOLFW2➂20➁ AOLFW2➂22➁ • Color Code and Operating Voltage Code LED Illuminated Type ➁ Lens/LED Color Code Specify a lens/LED color code in place of ➁ in the Type No. A: amber G: green PW: pure white R: red S: blue W: white Y: yellow • • • ∗ Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens Color Code Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber 116: Transformer (115V AC) G: green 126: Transformer (120V AC) R: red 26: Transformer (200/220V AC) S: blue 236: Transformer (230V AC) W: white 246: Transformer (240V AC) 386: Transformer (380V AC) 46: Transformer (400/440V AC) 486: Transformer (480V AC) Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36. LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). 15 TW_EP1070.book Page 16 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Illuminated Pushbuttons Round Extended with Full Shroud Illuminated Pushbuttons (Marking Type) Shape Round Extended (Marking) With Full Shroud ALFW2B AOLFW2B Operation Type Lamp Without Lamp Input Type Full Voltage Transformer Momentary LED DC-DC Converter∗ Incandescent Transformer Without Lamp Full Voltage Transformer Maintained LED DC-DC Converter∗ Incandescent Transformer Contact 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC Type No. ALFW2B9911➁ ALFW2B9920➁ ALFW2B9922➁ ALFW2B➂11D➁ ALFW2B➂20D➁ ALFW2B➂22D➁ ALFW2B1611DD➁ ALFW2B1620DD➁ ALFW2B1622DD➁ ALFW2B➂11➁ ALFW2B➂20➁ ALFW2B➂22➁ AOLFW2B9911➁ AOLFW2B9920➁ AOLFW2B9922➁ AOLFW2B➂11D➁ AOLFW2B➂20D➁ AOLFW2B➂22D➁ AOLFW2B1611DD➁ AOLFW2B1620DD➁ AOLFW2B1622DD➁ AOLFW2B➂11➁ AOLFW2B➂20➁ AOLFW2B➂22➁ • Color Code and Operating Voltage Code LED Illuminated Type ➁ Lens/LED Color Code Specify a lens/LED color code in place of ➁ in the Type No. A: amber G: green PW: pure white R: red S: blue W: white Y: yellow • • • ∗ Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens Color Code Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber 116: Transformer (115V AC) G: green 126: Transformer (120V AC) R: red 26: Transformer (200/220V AC) S: blue 236: Transformer (230V AC) W: white 246: Transformer (240V AC) 386: Transformer (380V AC) 46: Transformer (400/440V AC) 486: Transformer (480V AC) Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36. LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). 16 TW_EP1070.book Page 17 Wednesday, January 19, 2005 10:49 AM TW Series Illuminated Pushbuttons ø22 Square Extended Illuminated Pushbuttons (Marking Type) Shape Square Extended (Marking) ALQW2B AOLQW2B Operation Type Lamp Without Lamp Input Type Full Voltage Transformer Momentary LED DC-DC Converter∗ Incandescent Transformer Without Lamp Full Voltage Transformer Maintained LED DC-DC Converter∗ Incandescent Transformer Contact 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC Type No. ALQW2B9911➁ ALQW2B9920➁ ALQW2B9922➁ ALQW2B➂11D➁ ALQW2B➂20D➁ ALQW2B➂22D➁ ALQW2B1611DD➁ ALQW2B1620DD➁ ALQW2B1622DD➁ ALQW2B➂11➁ ALQW2B➂20➁ ALQW2B➂22➁ AOLQW2B9911➁ AOLQW2B9920➁ AOLQW2B9922➁ AOLQW2B➂11D➁ AOLQW2B➂20D➁ AOLQW2B➂22D➁ AOLQW2B1611DD➁ AOLQW2B1620DD➁ AOLQW2B1622DD➁ AOLQW2B➂11➁ AOLQW2B➂20➁ AOLQW2B➂22➁ • Color Code and Operating Voltage Code LED Illuminated Type ➁ Lens/LED Color Code Specify a lens/LED color code in place of ➁ in the Type No. A: amber G: green PW: pure white R: red S: blue W: white Y: yellow • • • ∗ Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens Color Code Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber 116: Transformer (115V AC) G: green 126: Transformer (120V AC) R: red 26: Transformer (200/220V AC) S: blue 236: Transformer (230V AC) W: white 246: Transformer (240V AC) 386: Transformer (380V AC) 46: Transformer (400/440V AC) 486: Transformer (480V AC) Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36. LED illuminated transformer and DC-DC converter types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). DC-DC converter types are not approved by UL, CSA, and TÜV, and not CE compliant (operating voltage 90 to 140V DC). 17 TW_EP1070.book Page 18 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Illuminated Pushbuttons Mushroom (ø29) Illuminated Pushbuttons Shape ø29 Mushroom ALW3 AOLW3 Operation Type Lamp Input Type Contact Type No. Without Lamp Full Voltage ALW39911➁ Incandescent Transformer ALW3➂11➁ Without Lamp Full Voltage AOLW39911➁ Incandescent Transformer Momentary Maintained ø29 Mushroom (Marking Type) ALW3B AOLW3B AOLW3➂11➁ 1NO-1NC Without Lamp Full Voltage ALW3B9911➁ Incandescent Transformer ALW3B➂11➁ Without Lamp Full Voltage AOLW3B9911➁ Incandescent Transformer AOLW3B➂11➁ Without Lamp Full Voltage LED Transformer Incandescent Transformer Without Lamp Full Voltage LED Transformer Incandescent Transformer Momentary Maintained ø29 Mushroom Pushlock Turn Reset AVLW3 ø29 Mushroom Pushlock Turn Reset (Marking Type) AVLW3B 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO 1NC 1NO-1NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC • Color Code and Operating Voltage Code Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens Color Code Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber 116: Transformer (115V AC) G: green 126: Transformer (120V AC) R: red 26: Transformer (200/220V AC) S: blue 236: Transformer (230V AC) W: white 246: Transformer (240V AC) 386: Transformer (380V AC) 46: Transformer (400/440V AC) 486: Transformer (480V AC) • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36. • LED illuminated transformer types contain an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). 18 AVLW39911R AVLW39920R AVLW39922R AVLW3➂11DR AVLW3➂20DR AVLW3➂22DR AVLW3➂11R AVLW3➂20R AVLW3➂22R AVLW3B9911R AVLW3B9920R AVLW3B9922R AVLW3B➂11DR AVLW3B➂20DR AVLW3B➂22DR AVLW3B➂11R AVLW3B➂20R AVLW3B➂22R TW_EP1070.book Page 19 Wednesday, January 19, 2005 10:49 AM TW Series Illuminated Pushbuttons ø22 Mushroom (ø40 mm) Illuminated Pushbuttons Shape ø40 Mushroom Pushlock Turn Reset AVLW4 Lamp Input Type Without Lamp Full Voltage LED Transformer Incandescent Transformer ø40 Mushroom Pushlock Turn Reset (Marking Type) AVLW4B Without Lamp Full Voltage ø40 Mushroom Push Pull AYLW4 (2-position maintained) LED Transformer Incandescent Transformer Without Lamp Incandescent ø40 Mushroom Push Pull (Marking Type) AYLW4B (2-position maintained) Without Lamp Incandescent Full Voltage Contact 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC 1NO 1NC 1NO-1NC 1NO-1NC 2NO 2NO-2NC 1NO-1NC 2NO 2NO-2NC Type No. AVLW49911R AVLW49920R AVLW49922R AVLW4➂11DR AVLW4➂20DR AVLW4➂22DR AVLW4➂11R AVLW4➂20R AVLW4➂22R AVLW4B9911R AVLW4B9920R AVLW4B9922R AVLW4B➂11DR AVLW4B➂20DR AVLW4B➂22DR AVLW4B➂11R AVLW4B➂20R AVLW4B➂22R 1NO-1NC AYLW49911➁ 2NO AYLW49920➁ 2NO-2NC AYLW49922➁ 1NO-1NC AYLW4➂11➁ 2NO AYLW4➂20➁ 1NO AYLW4B9911➁ 1NC AYLW4B9920➁ 1NO-1NC AYLW4B9922➁ 1NO-1NC AYLW4B➂11➁ 2NO AYLW4B➂20➁ Transformer Full Voltage Transformer • Color Code and Operating Voltage Code Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens Color Code Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber 116: Transformer (115V AC) G: green 126: Transformer (120V AC) R: red 26: Transformer (200/220V AC) S: blue 236: Transformer (230V AC) W: white (AYLW4 only) 246: Transformer (240V AC) 386: Transformer (380V AC) 46: Transformer (400/440V AC) 486: Transformer (480V AC) • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36. • LED illuminated transformer type contains an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). • Contact Statuses of Push-Pull Switch Contact ø40mm Mushroom Push-Pull Switch Push Pull 1NO 1NC 1NO-1NC 2NO 2NC Note: Push-pull switch can have a maximum of two contact blocks. 19 TW_EP1070.book Page 20 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Illuminated Pushbuttons Dimensions (Operator) Panel Thickness 1 to 6 37 ø29 ø24 37 25 Panel Thickness 1 to 6 ø29 ø24 Panel Thickness 1 to 6 Square Extended (marking) ALQW2B / AOLQW2B 37 Round Extended with Full Shroud (non-marking/marking) ALFW2 / ALFW2B / AOLFW2 / AOLFW2B 30 Round Extended (non-marking/marking) ALW2 / ALW2B / AOLW2 / AOLW2B 13 13 30 20 30 19 30 20 Marking plate: Marking plate: ø15.5mm 21mm Marking plate: ø15.5mm ø29 Mushroom (non-marking/marking) ALW3 / ALW3B / AOLW3 / AOLW3B ø29 Mushroom Pushlock Turn Reset (non-marking/marking) AVLW3 / AVLW3B Panel Thickness 1 to 6 Panel Thickness 1 to 6 Reset Angle: 75° Reset Angle 75° 13 30 13 22.5 37 13 30 22.5 Marking plate: ø13.9mm ø40 37 ø29 37 ø29 Panel Thickness 1 to 6 ø40 Mushroom Pushlock Turn Reset (non-marking/marking) AVLW4 / AVLW4B 22.5 Marking plate: ø13.9mm 30 Marking plate: ø13.9mm ø40 Mushroom Push Pull (non-marking/marking) AYLW4 / AYLW4B 37 ø40 Panel Thickness 1 to 6 13 25 30 30.5 Marking plate: ø13.9mm All dimensions in mm. Terminal Arrangement (Lamp Terminal) (Bottom View) • Arrows indicate access directions for wiring. TOP X1 TOP TOP X1 X1 X2 X2 20 X2 Full Voltage Type Full Voltage Type When using TW-DA1B Full Voltage Adapter for 2 or 4 contact blocks When using HW-DA1B Full Voltage Adapter for 1 or 3 contact blocks Transformer Type DC-DC Converter Type TW_EP1070.book Page 21 Wednesday, January 19, 2005 10:49 AM TW Series Illuminated Pushbuttons ø22 Dimensions (Behind the Panel) • Transformer Type • DC-DC Converter Type • Full Voltage Type M3.5 Terminal Screws Panel Thickness 1 to 6 M3.5 Terminal Screws Panel Thickness 1 to 6 X1 X1 X2 X2 1 contact block 48.5 When using HW-DA1B full-voltage adapter M3.5 Terminal Screws 2 contact blocks Panel Thickness 1 to 6 86.5 M3.5 Terminal Screws Panel Thickness 1 to 6 X1 X2 X1 X2 2 contact blocks 4 contact blocks 63.5 106.5 When using TW-DA1B full-voltage adapter Panel Thickness 1 to 6 X2 X1 M3.5 Terminal Screws 3 contact blocks 68.5 When using HW-DA1B full-voltage adapter M3.5 Terminal Screws Panel Thickness 1 to 6 X1 X2 4 contact blocks 83.5 When using TW-DA1B full-voltage adapter Note: For the push-pull type, a maximum of two contact blocks can be used. All dimensions in mm. • Contact Configuration and Codes Contact Configuration 1NO 1 block 1NC 1NO-1NC 2 blocks 2NO 2NC 2NO-1NC 1NO-2NC 3 blocks 3NO 3NC 3NO-1NC 2NO-2NC 4 blocks 1NO-3NC 4NO 4NC Code 10 01 11 20 02 21 12 30 03 31 22 13 40 04 21 TW_EP1070.book Page 22 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Selector Switches 90° 2-position Panel Thickness 1 to 6 48.5 (2 blocks) 10 (1NO) 11 (1NO-1NC) 20 (2NO) 22 (2NO-2NC) Contact Code 20 (2NO) 02 (2NC) 45° 3-position M3.5 Terminal Screws 22 (2NO-2NC) 40 (4NO) 04 (4NC) 3S ★ Contact Code Contact Block Mounting Position Operator Position Maintained L Type L R L C 1 L 37 — R ASW2110 ASW2210 ∗ ASW211 ASW2111 ASW2211 ∗ ASW220 ASW2120 ASW2220 ∗ ASW222 ASW2122 ASW2222 ∗ Maintained C R 2 Spring Return from Right — Spring Return from Left C Spring Return Two-way C R L C R L R L ASW320 ASW3120 ASW3220 ASW3320 ASW302 ASW3102 ASW3202 ASW3302 ASW322 ASW3122 ASW3222 ASW3322 ASW340 ASW3140 ASW3240 ASW3340 ASW304 ASW3104 ASW3204 ASW3304 ASW33S-243 ★ Maintained 3 4 5 — 2 3 1 4 — Maintained 2 1 Type R R NO 1 NO 2 NC 1 NC 2 NO 1 NO 2 NC 3 NC 4 NO 1 NO 2 NO 3 NO 4 NC 1 NC 2 NC 3 NC 4 NO 1 NO 2 NC 3 Dummy 4 Contact Operator Position Block Mounting Position L Spring Return from Left ASW210 L Type Spring Return from Right 30 25 R NO 1 Dummy 2 NO 1 NC 2 NO 1 NO 2 NO 1 NC 2 NO 3 NC 4 Contact Operator Position Block Mounting Position 13 68.5 (4 blocks) Contact Arrangement Chart Contact Code 30° 5-position / 45° 4-position ASW ø29 Shape ø24 No. of Positions Selector Switches (Knob Operator Type) 3 4 5 — • Contact Block Mounting Position and Contact Arrangement Chart Left Center Right 1 NC NC 2 ASW44S-407 ★ — 4S ★ L C R NC 3 NO 4 1 NO NO 1 2 NO NC 2 4S ★ ASW44S-411 ★ — 3 NC NC 3 4 NC NO 4 NO 1 NC 2 • For more contact 3S ★ ASW43S-461 ★ — NC 3 arrangement chart, Dummy 4 see pages 27 to 29. NO 1 3 NC 2 1 4S ★ — ASW54S-501 ★ NC 3 NO 4 • On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows. Operator Position 4 2 TOP • On the contact arrangement marked with ★ in the table above, the rated current (load switching current) is reduced to a half of the rated current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged. • Selector switches with one or three contact blocks contain a dummy block. • Knob operator: White indicator on black knob 22 TW_EP1070.book Page 23 Wednesday, January 19, 2005 10:49 AM TW Series Selector Switches ø22 90° 2-position 37 ø29 Panel Thickness 1 to 6 48.5 (2 blocks) 10 (1NO) 11 (1NO-1NC) 20 (2NO) 22 (2NO-2NC) Contact Code 20 (2NO) 02 (2NC) 45° 3-position M3.5 Terminal Screws Contact Arrangement Chart Contact Code 22 (2NO-2NC) 40 (4NO) 04 (4NC) 3S ★ Contact Code 30° 5-position / 45° 4-position ASW∗L Shape ø25 No. of Positions Selector Switches (Lever Operator Type) Contact Block Operator Position Maintained L Mounting Position Type L R L C 1 — R ASW21L10 ASW22L10 ∗ ASW2L11 ASW21L11 ASW22L11 ∗ ASW2L20 ASW21L20 ASW22L20 ∗ ASW2L22 ASW21L22 ASW22L22 ∗ Maintained C R 2 Spring Return from Right — Spring Return from Left C Spring Return Two-way C R L C R L R L ASW3L20 ASW31L20 ASW32L20 ASW33L20 ASW3L02 ASW31L02 ASW32L02 ASW33L02 ASW3L22 ASW31L22 ASW32L22 ASW33L22 ASW3L40 ASW31L40 ASW32L40 ASW33L40 ASW3L04 ASW31L04 ASW32L04 ASW33L04 — — — ASW3L3S-243 ★ Maintained 3 4 5 Maintained 2 1 Type L R NO 1 NO 2 NC 1 NC 2 NO 1 NO 2 NC 3 NC 4 NO 1 NO 2 NO 3 NO 4 NC 1 NC 2 NC 3 NC 4 NO 1 NO 2 NC 3 Dummy 4 Contact Operator Position Block Mounting Position R L Spring Return from Left ASW2L10 L Type Spring Return from Right 30 25 R NO 1 Dummy 2 NO 1 NC 2 NO 1 NO 2 NO 1 NC 2 NO 3 NC 4 Contact Operator Position Block Mounting Position 13 68.5 (4 blocks) 2 3 1 4 3 4 5 • Contact Block Mounting Position and Contact Arrangement Chart Left Center Right 1 NC NC 2 4S ★ ASW4L4S-407 ★ — Operator L C R NC 3 Position NO 4 1 NO NO 1 2 NO NC 2 4S ★ ASW4L4S-411 ★ — 3 NC NC 3 4 NC NO 4 4 NO 1 TOP 2 • For more contact NC 2 3S ★ ASW4L3S-461 ★ — arrangement chart, NC 3 see pages 27 to 29. Dummy 4 NO 1 3 NC 2 1 4S ★ — ASW5L4S-501 ★ NC 3 NO 4 • On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows. • On the contact arrangement marked with ★ in the table above, the rated current (load switching current) is reduced to a half of the rated current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged. • Selector switches with one or three contact blocks contain a dummy block. • Lever operator: White indicator on black lever 23 TW_EP1070.book Page 24 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Selector Switches Key Selector Switches Panel Thickness 1 to 6 48.5 (2 blocks) 90° 2-position Contact Code Contact Block Type L 11 (1NO-1NC) 20 (2NO) 22 (2NO-2NC) Mounting Position R L R Spring Return from Left L — R ASW2K10 ASW21K10 ASW22K10 ∗ ASW2K11 ASW21K11 ASW22K11 ∗ ASW2K20 ASW21K20 ASW22K20 ∗ ASW2K22 ASW21K22 ASW22K22 ∗ Maintained L C Spring Return from Right R L — Spring Return from Left C C L Type Spring Return from Right 30 41 R NO 1 Dummy 2 NO 1 NC 2 NO 1 NO 2 NO 1 NC 2 NO 3 NC 4 Contact Operator Position Block 10 (1NO) Contact Code Maintained Operator Position L Mounting Position 13 19 68.5 (4 blocks) Contact Arrangement Chart 37 ø24 No. of Positions M3.5 Teminal Screws ø29 ASW∗K Shape Spring Return Two-way C R L C R L R R NO 1 ASW3K20 ASW31K20 ASW32K20 ASW33K20 NO 2 NC 1 02 ASW3K02 ASW31K02 ASW32K02 ASW33K02 (2NC) NC 2 NO 1 22 NO 2 ASW3K22 ASW31K22 ASW32K22 ASW33K22 NC (2NO-2NC) 3 NC 4 NO 1 40 NO 2 ASW3K40 ASW31K40 ASW32K40 ASW33K40 NO (4NO) 3 NO 4 NC 1 04 NC 2 ASW3K04 ASW31K04 ASW32K04 ASW33K04 NC (4NC) 3 NC 4 NO 1 NO 2 3S ★ ASW3K3S-243 ★ — — — NC 3 Dummy 4 • On the spring-returned types, the key can be released only from the maintained position. On the maintained types, the key can be released from every position. Key retained positions are also available. See page 7. • On the 2-position selector switches marked with ∗ above, the contact operation is reversed as follows. 20 45° 3-position (2NO) • On the contact arrangement marked with ★ in the table above, the rated current (load switching current) is reduced to a half of the rated current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged. • Key selector switches with one or three contact blocks contain a dummy block. • Cylinder cover: Black, Cylinder: Metal • Contact Block Mounting Position and Contact Arrangement Chart 4 Center Left 2 L 3 1 Right TOP 1 2 3 4 C R NO NO NC NC • For more contact arrangement chart, see pages 27 to 29. 24 Operator Position TW_EP1070.book Page 25 Wednesday, January 19, 2005 10:49 AM TW Series Selector Switches ø22 Illuminated Selector Switches 90° 2-position ASLW M3.5 Terminal Screws 13 A: 63.5 (2 blocks) 83.5 (4 blocks) Contact Code Contact Block Maintained Operator Position Lamp Input Type L R 30 25 A: Rated voltage 24V AC/DC B: Rated voltage 100/110V AC, 200/220V AC B: 86.5 (2 blocks), 106.5 (4 blocks) Contact Arrangement Chart 37 ø24 Panel Thickness 1 to 6 ø29 Shape Spring Return from Right L R Spring Return from Left L R Mounting Position Type 1 NO Without Lamp Full Voltage ASLW29911➁ ASLW219911➁ ASLW229911➁ 2 NC LED Transformer ASLW2➂11D➁ ASLW21➂11D➁ ASLW22➂11D➁ Incandescent Transformer ASLW2➂11➁ ASLW21➂11➁ ASLW22➂11➁ 11 (1NO-1NC) 20 (2NO) 22 R 1 NO Without Lamp Full Voltage ASLW29920➁ ASLW219920➁ ASLW229920➁ 2 NO LED Transformer ASLW2➂20D➁ ASLW21➂20D➁ ASLW22➂20D➁ Incandescent Transformer ASLW2➂20➁ ASLW21➂20➁ ASLW22➂20➁ Without Lamp Full Voltage ASLW29922➁ ASLW219922➁ ASLW229922➁ LED Transformer ASLW2➂22D➁ ASLW21➂22D➁ ASLW22➂22D➁ Incandescent Transformer ASLW2➂22➁ ASLW21➂22➁ ASLW22➂22➁ 1 2 3 4 (2NO-2NC) L NO NC NO NC • Color Code and Operating Voltage Code LED Illuminated Type ➁ Lens/LED Color Code Specify a lens/LED color code in place of ➁ in the Type No. Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens Color Code Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber 156: Transformer (115V AC) G: green 136: Transformer (120V AC) R: red 26: Transformer (200/220V AC) S: blue 236: Transformer (230V AC) W: white 256: Transformer (240V AC) 386: Transformer (380V AC) 46: Transformer (400/440V AC) 486: Transformer (480V AC) A: amber G: green PW: pure white R: red S: blue W: white Y: yellow • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36. • LED illuminated transformer type contains an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). • Contact Block Mounting Position and Contact Arrangement Chart 4 2 Left TOP Right L 3 1 1 2 3 4 R NO NC NO NC Operator Position • For more contact arrangement chart, see pages 27 to 29. 25 TW_EP1070.book Page 26 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Selector Switches Illuminated Selector Switches 45° 3-position Contact Block Contact Code Mounting Type Position 20 (2NO) 02 (2NC) 22 (2NO-2NC) 40 (4NO) 04 (4NC) 1 NO 2 NO 1 NC 2 NC 1 2 3 4 NO NO NC NC 1 2 3 4 NO NO NO NO 1 2 3 4 NC NC NC NC Operator Position L C Maintained Spring Return from Right Spring Return from left C C C Lamp Input Type R R L Without Lamp Full Voltage LED Transformer Incandescent Transformer Without Lamp Full Voltage LED Transformer Incandescent Transformer Without Lamp Full Voltage LED Transformer Incandescent Transformer Without Lamp Full Voltage LED Transformer Incandescent Transformer Without Lamp Full Voltage LED Transformer Incandescent Transformer L R L Spring Return Two-way C R L R ASLW39920 ASLW319920 ASLW329920 ASLW339920 ASLW3➂20D➁ ASLW31➂20D➁ ASLW32➂20D➁ ASLW33➂20D➁ ASLW3➂20➁ ASLW31➂20➁ ASLW32➂20➁ ASLW33➂20➁ ASLW39902 ASLW319902 ASLW329902 ASLW339902 ASLW3➂02D➁ ASLW31➂02D➁ ASLW32➂02D➁ ASLW33➂02D➁ ASLW3➂02➁ ASLW31➂02➁ ASLW32➂02➁ ASLW33➂02➁ ASLW39922 ASLW319922 ASLW329922 ASLW339922 ASLW3➂22D➁ ASLW31➂22D➁ ASLW32➂22D➁ ASLW33➂22D➁ ASLW3➂22➁ ASLW31➂22➁ ASLW32➂22➁ ASLW33➂22➁ ASLW39940 ASLW319940 ASLW329940 ASLW339940 ASLW3➂40D➁ ASLW31➂40D➁ ASLW32➂40D➁ ASLW33➂40D➁ ASLW3➂40➁ ASLW31➂40➁ ASLW32➂40➁ ASLW33➂40➁ ASLW39904 ASLW319904 ASLW329904 ASLW339904 ASLW3➂04D➁ ASLW31➂04D➁ ASLW32➂04D➁ ASLW33➂04D➁ ASLW3➂04➁ ASLW31➂04➁ ASLW32➂04➁ ASLW33➂04➁ • Color Code and Operating Voltage Code LED Illuminated Type Incandescent Illuminated Type ➂ Operating Voltage Code ➁ Lens Color Code Specify a lens color code in place of Specify an operating voltage code in place of ➂ in the Type No. ➁ in the Type No. 16: Transformer (100/110V AC) A: amber 156: Transformer (115V AC) G: green 136: Transformer (120V AC) R: red 26: Transformer (200/220V AC) S: blue 236: Transformer (230V AC) W: white 256: Transformer (240V AC) 386: Transformer (380V AC) 46: Transformer (400/440V AC) 486: Transformer (480V AC) ➁ Lens/LED Color Code Specify a lens/LED color code in place of ➁ in the Type No. A: amber G: green PW: pure white R: red S: blue W: white Y: yellow • Full voltage types do not contain a lamp. Order LED or incandescent lamps separately. For lamps, see page 36. • LED illuminated transformer type contains an LED lamp (LSTD-6➁, rated voltage 6V AC/DC). • Incandescent illuminated transformer types contain an incandescent lamp (LS-6, rated voltage 6V AC/DC). • Contact Block Mounting Position and Contact Arrangement Chart 4 Center Left 2 L 3 1 26 Right TOP 1 2 3 4 NO NO NC NC C R Operator Position • For more contact arrangement chart, see pages 27 to 29. TW_EP1070.book Page 27 Wednesday, January 19, 2005 10:49 AM TW Series Selector Switch Contact Arrangement Charts ø22 90° 2-position (Maintained / Spring Return) Maintained Positions L R Operator Types Spring Return from Right Spring Return from Left L R L R Knob, Lever, Key, Illuminated Operator Positions Contact Code Circuit Mounting No. Position Type L 10 (1NO) 01 (1NC) 11 (1NO-1NC) 20 (2NO) 02 (2NC) — — — 103 — — — 109 22 (2NO-2NC) 110 111 117 31 (3NO-1NC) 40 (4NO) 107 — 118 ★ 2R ★ 168 ★ 119 ★ 169 ★ 120 ★ 170 ★ 4R ★ 121 ★ 171 ★ 1 2 1 2 1 2 1 2 1 2 1 2 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 1 2 1 2 1 2 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 NO Dummy NC Dummy NO NC NC NO NO NO NC NC NO NC NO NC NO NC NC NO NC NO NC NO NO NO NC NC NC NO NO NC NC NO NO NO NO NO NO NO NO NC NO NC NC NO NC NO NO NC NO NC NO NC NO NC NC NO NC NO NC NO NC NO R L R • Contact Block Mounting Position and Contact Arrangement Chart 4 3 TOP 2 1 Left Right L 1 2 3 4 R NO NC NO NC Operator Position • On the contact arrangement marked with ★ in the table, the rated current (load switching current) is reduced to a half of the rated current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged. Type No. Development • When circuit number is not required: ASW 2 11 Contact Code (1NO-1NC) 2-position • When circuit number is required: ASW 2 11 - 103 Circuit No. Contact Code (1NO-1NC) 2-position 27 TW_EP1070.book Page 28 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Selector Switch Contact Arrangement Charts 45° 3-position (Maintained / Spring Return) Maintained Positions Spring Return Spring Return Spring Return from Right from Left Two-way C C Operator Types C C R L R L L R L R Knob, Lever, Key, Illuminated Operator Positions Contact Code Circuit Mounting No. Position Type L 202 203 11 302 303 — 20 301 — 02 304 — 210 22 (2NO-2NC) 308 309 310 206 31 (3NO-1NC) 207 212 13 313 — 40 305 — 04 314 28 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 NO NC NC NO NO NC NC NO NO NO NO NO NC NC NC NC NO NO NC NC NC NO NC NO NO NC NO NC NO NC NC NO NC NO NC NO NO NC NO NO NC NO NO NO NO NC NC NC NC NO NC NC NO NO NO NO NO NO NO NO NC NC NC NC NC NC NC NC C R • Contact Block Mounting Position and Contact Arrangement Chart 4 3 1 Center Left L 1 2 3 4 TOP 2 C Right R NO NO NC NC Operator Position Type No. Development • When circuit number is not required: ASW 3 22 Contact Code (2NO-2NC) 3-position • When circuit number is required: ASW 3 22 - 210 Circuit No. Contact Code (2NO-2NC) 3-position TW_SS Page 29 Wednesday, January 19, 2005 1:55 PM TW Series Selector Switch Contact Arrangement Charts ø22 45° 3-position (Maintained) 45° 4-position (Maintained) Maintained Maintained C Positions L 2 Positions R 3 1 4 Operator Types Contact Code Circuit No. Mounting Position Knob, Lever, Key, Illuminated Operator Types Operator Positions Contact Code Type 3S ★ 1361 ★ 243 ★ 233 ★ 234 ★ 4S ★ 235 ★ 237 ★ 240 ★ 1 2 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Operator Positions Circuit No. Mounting Position Type 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 NO NC NC 1 L 2S ★ Knob, Lever C R NO NC NO NO NC 3S ★ 461 ★ 405 ★ Dummy NO NC NO NO NO NC NC NC NC NO NC NO NO NO NC NO NC NC NC NO 407 ★ 4S ★ 409 ★ 411 ★ 2 3 4 Dummy NC NC NC NC NC NC NC NO NO NC NC NC NO NC NC NO 30° 5-position (Maintained) Maintained Positions 2 Operator Types 5 Knob, Lever Contact Code Circuit No. Mounting Position Type 501 ★ 1 2 3 4 NO NC NC NO Maintained 1 C L R 4S ★ Knob, Lever, Illuminated Operator Types 4 Operator Positions 45° 3-position (Maintained) Positions 3 1 2 3 4 5 Operator Positions Contact Code Circuit No. Mounting Position Type 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 NO NO NC NC NC NO NC NC NO NC NC NO NO NC NO NC NC NC NC NC L 1336 ★ 1337 ★ 4S★ 1352 ★ 1355 ★ 1359 ★ C 4 R 2 TOP Center Left L 3 1 1 2 3 4 NO NC NO NO C Right R Operator Position • On the contact arrangement marked with ★ in the table, the rated current (load switching current) is reduced to a half of the rated current of the contact block. The rated insulation voltage and the rated thermal current remain unchanged. 29 TW_EP1070.book Page 30 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Accessories and Replacement Parts Accessories Terminal Cover HW-VL2 HW-VL3 HW-VL4 HW-VL5 HW-VL6 APS-PVL Use of terminal covers increases the depth by the dimensions below. Terminal Cover Control Unit • Pilot light APW APQW 39.8H × 14.1W 37.8H × 26W 39.8H × 8.7W 39.1H × 15.5W 40H × 14.8W Full Voltage 36H × 29.4W X +6mm X +3mm X +3mm Transformer DC-DC Converter • Pushbutton 1 contact block ABW AOW CB Terminal Cover AVW ABQW ABFW AJW 2 contact blocks AOQW AOFW CB AXW CB ABGW AYW 3 contact blocks • Selector switch CB CB ASW CB X X 2 pieces +3.5mm X 2 pieces 4 contact blocks CB CB CB CB • Illuminated Full Voltage, 1 or 3 contact blocks pushbutton ALW CB AOLW FA ALFW AOLFW ALQW Full Voltage, 2 or 4 contact blocks AOLQW AVLW CB AYLW CB • Illuminated selector switch ASLW X 2 pieces X 2 pieces +3.5mm X For contact blocks 2 pieces +3mm Transformer DC-DC Converter CB CB Tr X • Ordering Terminal Covers Terminal covers are ordered separately. When ordering terminal covers, specify the Type No. and required quantity. 30 X For full voltage adapter +3mm TW_EP1070.book Page 31 Wednesday, January 19, 2005 10:49 AM TW Series Accessories and Replacement Parts ø22 Nameplates NWA, NWAQ, NWAS, NWAR, NWAL, NWAQL, and NWAV Dimensions (mm) NWA Legend Blank 29 Type No. NWA-∗ With Legend NWAQ Blank 29 NWAQ-∗ 21 With Legend 14.5 Package Quantity NWA-0 1 NWA-0PN10 10 NWA-∗ 1 NWA-∗PN10 10 NWAQ-0 1 NWAQ-0PN10 10 NWAQ-∗ 1 NWAQ-∗PN10 10 NWAS-0 1 Description Black NWAQ-0 Aluminium 0.8 mm thick OFF Ordering Type No. NWA-0 Aluminium 0.8 mm thick OFF 20 Material White letters on black background Black White letters on black background NWAS 45 45 Blank Aluminium 0.8 mm thick NWAS-0 RGENC ME Blank ø70 STOP NWAS-0PN10 10 NWAR-0 1 NWAR-0PN10 10 NWAR-27 1 NWAR-27PN10 10 NWAL-0 1 NWAR-0 Aluminium 0.8 mm thick Y E NWAR Black EMERGENCY STOP Yellow NWAR-27 Black letters on yellow background NWAL 29 25 Blank Aluminium 0.8 mm thick NWAL-0 Black NWAL-0PN10 10 NWAQL-0 1 NWAQL 29 NWAQL-0 Black NWAQL-0PN10 10 HWAV-0 HWAV-0 1 Yellow HWAV-27 HWAV-27 1 Black letters on yellow background 14.5 25 Blank Aluminium 0.8 mm thick HWAV Blank ø60 Plastic EMERGENCY STOP • Specify a legend code in place of ∗ in the Ordering Type No. Legends Code 0 1 2 3 4 31 35 53 Legend (blank) ON OFF START STOP OFF-ON HAND-AUTO HAND-OFF-AUTO 31 TW_EP1070.book Page 32 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Accessories and Replacement Parts Accessories Material Type No. Ordering Type No. Package Quantity Dimensions OR-14 OR-14 1 90 ø34 Rubber ø31 • Used to tighten the locking ring when installing the TW control unit onto a panel. Locking Ring Wrench ø46 Shape 16 For ø22mm units (close mounting) For ø22/ø25mm units OR-55 OR-55 1 ø14 Rubber ø11.6 • Used to install and remove LED/incandescent lamps. Lamp Holder Tool 59 • Used to remove contact blocks, transformers, lenses and adapters. Can also be used to determine panel thickness adjustment. 23 Contact Block Removal Tool TW-KC1 TW-KC1 1 130 39 ø19 Metal/Rubber • Used to tighten the locking nuts inside of the square bezel.This tool can be inserted into the OR-14 locking ring wrench. Nut Locking Wrench 20 TW-KQ2 TW-KQ2 1 25.7 22.5 Metal 80 • Used to prevent the operator from rotating. Generally used when using no nameplates on selector switches. Anti-rotation Ring OGL-31 OGL-31PN10 10 10.2 Metal ø22 ø27.4 0.8 • Used to plug unused ø22.2mm mounting holes. Rubber Mounting Hole Plug ø29 5 LW9Z-BM LW9Z-BM 1 ø25.8 12 Gasket Plastic HW-VL1 HW-VL1PN10 10 • Used to prevent contact between adjacent lead wires when units are mounted closely. Barriers should be always used in close mounting. 45 Locking Ring Barrier 20 32 3 • Used to plug unused ø22.2mm mounting holes. • Tightening torque: 1.2 N·m • Degree of protection: IP66 (without the 3.2mm recess in the mounting hole) Metallic Mounting Hole Plug Diecast Metal (locking ring: plastic) ø25 3.5 OB-31PN05 3.5 Rubber (black) OB-31 1.5 TW_Accessory Page 33 Wednesday, January 19, 2005 1:40 PM TW Series Accessories and Replacement Parts ø22 Accessories OCW-99 Ordering Type No. OCW-99 Package Quantity 1 Description • Oiltight rubber boot used for pushbuttons and selector switches. • Temperature range: –5 to +60°C • Black OCW-99 Rubber (nitryl) OCW-299 OCW-299 1 50 For 2 layers of contact blocks (4 contact blocks) OCW-299 OC-32 OC-32 1 Rubber (EPDM) For extended pushbuttons (ABW2/AOW2) Button Cover For flush pushbuttons (ABW1/AOW1) OCW-10➀ OCW-10➀ 1 Rubber (nitryl) 18 (OC-31) 22 (OC-32) • Metallic bezels covered with rubber boot to enhance waterproof and oiltight characteristics. • Button is installed in the cover. Remove the button from the pushbutton before using the button cover. • ➀: B (black), G (green), R (red), Y (yellow) 9 M22 P1.0 ø32 For extended pushbuttons (ABW2/AOW2) OCW-11➀ OCW-11➀ 9 M22 P1.0 1 ø26 1 ø32.6 OC-31 ø32 OC-31 • Used to cover and protect pushbuttons where units are subject to water splash. Not suitable for outdoor use or where the units are subject to oil splash. ø31 For flush pushbuttons (ABW1/AOW1) 65.5 14 38 Pushbutton Clear Boot 45.5 14 38 Button installed 18.5 21 ø31 For 1 layer of contact blocks (2 contact blocks) Type No. 2.2 Contact Rubber Boot Material 48 Shape Button installed Extended Flush • Used to protect momentary and maintained pushbuttons, illuminated pushbuttons, knobs selector switches, and key selector switches. Padlock Cover 82.5 1 93 70 30 HW9Z-KL1 6.5 HW9Z-KL1 R6 Polyarylate (gasket: nitryl rubber) Panel Thickness 0.8 to 3.2 24 (inside) ALW4L-➁ 2 ALW4L-➁ 2. ø40mm Lens ø2 0 4) ø5 44. :ø (ID Key hole ø8 • Applicable unit: ALW3, AOLW3 ALW4LD-➁ ALW4LD-➁ 1 ALW4BL-➁ ALW4BL-➁ 1 Waterproof Rubber Gasket 0.5t ➁: G (green), R (red) 1 Non-marking Type 29.5 30 S (blue) ➁: A (amber), W (white) Plastic Marking Type ALW4BLD-➁ ALW4BLD-➁ 1 • Applicable unit: ALW3B, AOLW3B • Marking plate is included ➁: G (green), R (red), S (blue), W (white) ➁: A (amber) Note: Specify a button color code or lens color code in place of ➀ or ➁ in the Ordering Type No. 33 TW_EP1070.book Page 34 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Accessories and Replacement Parts Accessories AW-RP1BPN05 5 ➁Extended AW-FP1B AW-FP1B 1 AW-FP2B AW-FP2B 1 ➂Extended (for illuminated Plastic pushbuttons) ➃Square round (for round pushbuttons) ➅ ➂ AW-Q1B AW-Q1B 1 AW-R1 AW-R1PN05 5 Aluminium color (standard) AW-R1B AW-R1B 1 Black AW-F1 AW-F1 1 AW-F2 AW-F2 1 AW-G4 AW-G4 1 ➀Knob ASWHHY-➁ ASWHHY-➁PN02 2 ➁Lever ASWHHL-➁ ASWHHL-➁PN02 2 ➂Round ASWHHM-B ASWHHM-BPN02 2 Black only ➂Extended (for illuminated pushbuttons) Aluminium ➃Mushroom Selector Operator ➁ ➀ ➂ ➃Color Insert ➄ ➃ ➂ 1 ➁Extended Plastic ➄Illuminated selector ø29 ø29 AW-H1B ➀Flush ➁ Black AW-H1B ➄Square Aluminium Bezel ➀ ➁ ➀ 19.8 AW-RP1B 13 ➀Flush Dimensions ➃ 13 ➄ ➃ Package Quantity ø29 30 ➄ 13 ➂ Ordering Type No. Type No. 19.8 Plastic Bezel ➁ ➀ Material 30 Aluminium color (standard) ➅ 23 23 Shape ø46 ø46 Specify a color code in place of ➁. B (black), G (green), R (red) TW-HC1➁ TW-HC1➁PN05 5 Specify a color code in place of ➁. B (black), G (green), R (red), S (blue), W (white), Y (yellow) ASLWDDY-➁ ASLWDDY-➁ 1 Specify a color code in place of ➁. A (amber), W (white), Y (yellow) ASLWLDY-➁ ASLWLDY-➁ 1 Specify a color code in place of ➁. G (green), R (red), S (blue) • Used to protect flush pushbuttons from inadvertent operation. Metal Protector Metal OLW-C OLW-C Mounting Centers 50 min. 18.6 1 ø22.5 R4 2.5 15 1.6t Maintenance Parts Shape Contact Block Specification Type No. Ordering Type No. Package Quantity Push Rod 1NO contact HW-C10 HW-C10 1 Blue Green 1NC contact HW-C01 HW-C01 1 Purple red Red EM contact (early make) LB contact (late break) HW-C10R HW-C10R 1 Blue Black HW-C01R HW-C01R 1 Purple red White Dummy Block TW-DB TW-DBPN10 10 Full Voltage Adapter (for 2 or 4 contact blocks) TW-DA1B TW-DA1BPN02 2 HW-DA1B HW-DA1BPN02 2 Full Voltage Adapter (for 1 or 3 contact blocks) 34 Color Housing • Used for non-illuminated units with 1NO or 1NC contact blocks. • Black • Adapter with M3.5 screws used for illuminated pushbutton or illuminated selector switch. Snaps on to the back of the contact block. • Used with 2 or 4 contact blocks. • Black • Adapter with M3.5 screws used for illuminated pushbuttons or illuminated selector switch. • Used with 1 or 3 contact blocks. • Black TW_EP1070.book Page 35 Wednesday, January 19, 2005 10:49 AM TW Series Accessories and Replacement Parts ø22 Maintenance Parts Shape Lens (for pilot lights) Material AS Round flush Round extended Square flush Lens (for illuminated pushbuttons) Round extended Square extended ø29mm mushroom APQW11L-➁ AS, Marking type APQW11LD-➁ ALW2L-➁ AS ALW2LD-➁ ALW21L-➁ AS, Marking type ALW21LD-➁ AS APW11L-➁PN05 5 APW11LD-➁PN05 APW2L-➁PN05 APW2LD-➁PN05 5 5 5 APQW11L-➁PN05 5 APQW11LD-➁PN05 ALW2L-➁PN05 ALW2LD-➁PN05 5 5 5 ALW21L-➁PN05 5 ALW21LD-➁PN05 5 ALQW21L-➁PN05 5 ALQW21LD-➁ ALQW21LD-➁PN05 ALW3L-➁ ALW3L-➁PN02 ALW3LD-➁ ALW3LD-➁PN02 5 2 2 ALW31L-➁PN02 2 2 2 AVLW31L-RPN02 2 AS AVLW4L-R AVLW4L-RPN02 2 Round flush ABW1B-➀ ABW1B-➀PN05 5 Round extended ABW2B-➀ ABW2B-➀PN05 5 Square flush ABQW1B-➀ ABQW1B-➀PN05 5 Square extended ABQW2B-➀ ABQW2B-➀PN05 5 ø29mm mushroom ABW3B-➀ ABW3B-➀PN02 2 ABW4B-➀ ABW4B-➀PN02 2 ø40mm mushroom Marking Plate (for illuminated pushbuttons) APW1L-➁PN05 APW1LD-➁PN05 Package Color Code Quantity G (green), R (red), S (blue) 5 A (amber), W (white), Y (yellow) 5 ALW31LD-➁PN02 AVLW3L-RPN02 ø40mm mushroom Marking Plate (for pilot lights) ALQW21L-➁ Ordering Type No. ALW31L-➁ AS, Marking type ALW31LD-➁ AS AVLW3L-R AS, Marking type AVLW31L-R ø29mm mushroom Button APW1L-➁ APW1LD-➁ APW11L-➁ AS, Marking type APW11LD-➁ APW2L-➁ AS APW2LD-➁ AS Lens (for pushlock turn reset) Type No. Polyacetal C (clear), G (green), R (red), S (blue) A (amber), Y (yellow) G (green), R (red), S (blue) A (amber), W (white), Y (yellow) C (clear), G (green), R (red), S (blue) A (amber), Y (yellow) G (green), R (red), S (blue) A (amber), W (white), Y (yellow) C (clear), G (green), R (red), S (blue) A (amber), Y (yellow) C (clear), G (green), R (red), S (blue) A (amber), Y (yellow) G (green), R (red), S (blue) A (amber), W (white), Y (yellow) C (clear), G (green), R (red), S (blue) A (amber), Y (yellow) B (black) G (green) R (red) S (blue) W (white) Y (yellow) ø29mm pushlock turn reset ø40mm pushlock turn reset AVW3B-➀ AVW3B-➀PN02 2 R (red), Y (yellow) AVW4B-➀ AVW4B-➀PN02 2 R (red), Y (yellow) ø40mm push pull AYW4B-➀ AYW4B-➀PN02 2 B (black), G (green), R (red), S (blue), W (white), Y (yellow) Round flush APW2B APW2BPN05 5 Square flush APQW1B APQW1BPN05 5 ALW2B ALW2BPN05 5 Square extended ALQW2B ALQW2BPN05 5 ø29/40mm mushroom ALW3B ALW3BPN05 5 For APQW APW00LN APW00LNPN05 5 APW00L APW00LPN05 5 Round extended Acrylic • White Waterproof Lens Acrylic For ALQW Note: Specify a button color code or lens color code in place of ➀ or ➁ in the Ordering Type No. Use a clear lens for white or pure white illumination. 35 TW_EP1070.book Page 36 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Accessories and Replacement Parts Maintenance Parts Shape Material Type No. Ordering Type No. Package Quantity Metal TW-SK-0 TW-SK-0PN02 2 Spare Key For Key Selector Switch For Pushlock Key Reset LED Lamps (LSTD Type) Current Draw Operating Voltage AC Ordering Type No. Type No. DC 6V AC/DC ±5% 17 mA (A, R, W, Y) 14 mA (A, R, W, Y) 8 mA (G, PW, S) 5.5 mA (G, PW, S) LSTD-6➁ LSTD-6➁ LSTD-1➁ LSTD-1➁ 10 mA LSTD-1➁PN10 24V AC/DC ±10% LSTD-2➁ 11 mA Incandescent Lamps (LS Type) Lamp Ratings Type No. 1W (6.3V) LS-6 1W (18V) LS-8 Package Quantity 12V AC/DC 1 18V AC/DC 1W (24V) LS-2 1W (30V) LS-3 24V AC/DC Transformer Shape Transformer Unit Primary Voltage Secondary Voltage 100/110V AC Type No. TW-T16B 120V AC TW-T126B 5.5V 36 Specify a color code in place of ➁ in the Ordering Type No. 1 200/220V AC TW-T26B 240V AC TW-T246B Base 10 A: amber G: green PW: pure white R: red S: blue W: white Y: yellow 1 BA9S/13 10 1 LSTD-2➁ 10 mA LSTD-2➁PN10 Rated Operating Voltage 6V AC/DC Package Quantity LSTD-6➁PN10 12V AC/DC ±10% 11 mA Illumination Color Code 10 TW_Instructions Page 37 Wednesday, January 19, 2005 2:02 PM TW Series Instructions ø22 Safety Precautions • Turn off the power to the TW series control units before starting installation, removal, wiring, maintenance, and inspection of the products. Failure to turn power off may cause electrical shocks or fire hazard. • To avoid a burn on your hand, use the lamp holder tool when replacing lamps. • For wiring, use wires of a proper size to meet the voltage and current requirements. Tighten the M3.5 terminal screws to a tightening torque of 1.0 to 1.3 N·m. Failure to tighten terminal screws may cause overheat and fire. • Use HW-C type contact blocks for the TW series. Do not replace with or add conventional TW series contact blocks. Using a different type of contact block may lead to malfunction. HW-C Type Contact Block TW Type Contact Block Rectangular Holes Instructions Panel Mounting Panel thickness adjustment ring is used for the TW series. To attach the TW series to the panel, follow the procedures below. ➀Panel Thickness Adjustment ➁Attaching the Unit to the Panel with the Bezel ➂Attaching the Button, Lens, and Knob Bezel Mounting order Panel thickness adjustment ring Panel Lens Panel Installation method Type Attach the unit with the panel thickness scale facing up. Remarks Contact block removal tool Panel thickness adjustment z Adjusting Panel Thickness The panel thickness ring provides adjustment from 1 to 6 mm in 1-mm increments. Set the panel thickness to line A. Rotate the ring until the desired thickness indication around the periphery is aligned with line A, as shown below. Scale on Adjustment (in 0.1 mm) 0.2 0.3 0.4 For installing or removing waterproof lenses after the bezel is attached. 1.6 mm 0.5 0.6 0.7 0.8 0.9 0 2.3 mm 2 3 4 5 1 mm Panel Thickness Adjustment Ring Panel Thickness Scale (in 1 mm on the operator) 6 1 mm A Ex. Panel thickness 2 mm Contact Block Removal Tool 3.5 mm 1 2 4 6 For installing or removing round lenses. • Using the Contact Block Removal Tool to Adjust Panel Thickness Panel thickness can easily be adjusted to the values shown below by inserting the contact block removal tool between the adjustment ring and base. 0.1 mm 3 5 Screw in For tightening or removing square bezels. Tools Nut locking wrench 0.1 Press in 29mm/40mm mushroom button/lens, Dome lens For tightening or removing round bezels. Locking ring wrench 0 Method Flush/Extended pushbuttons, Square lens, Selector operator 3 5 4 6 2 mm 3.2 mm Ex. Panel thickness 2.6 mm Note: When a nameplate or an anti-rotation ring is used, add 0.8mm to the panel thickness. Total thickness = Panel thickness + 0.8mm (nameplate or anti-rotation ring thickness) 37 TW_EP1070.book Page 38 Wednesday, January 19, 2005 10:49 AM ø22 TW Series Instructions Instructions Mounting into Panel Cut-out with Bezel • Insertion into Panel Cut-out Insert the base into the panel cut-out making sure that the panel thickness scale is facing up. Panel thickness adjustment ring • Round Bezel All round bezels are screw-in type. Be sure to use the locking ring wrench to tighten the bezel. Locking Ring Wrench OR-14 (optional) Side B • Square Bezel 1. Insert the base plate from the front. Base Plate 2. Insert the lock nut. For easy installation, use the nut locking wrench. Lock Nut Remove Tighten Nut Locking Wrench TW-KQ2 (optional) 3. Mount the square bezel. The bezel will snap onto the base plate. Side A Square Bezel Use side B when mounting the units closely. • Recommended tightening torque is 2.0 N·m. Square Lens Press in [Square Illuminated Pushbutton] Flat screwdriver (5mm wide at maximum) 2. Removing the Marking Plate • Pilot Light Insert the screwdriver into the recess of the lens. Marking Plate Small flat screwdriver Lens Retainer Waterproof Lens • Illuminated Pushbuttons Insert the screwdriver into the hook and lightly push out the lens. [Round Marking Type] Lens Marking Plate Press in 38 Flat screwdriver (5mm wide at maximum) 3. Other Notes The square lens of the illuminated pushbutton cannot be used without waterproof lens. Always use the waterproof lens. Be sure to use the marking plate even when it is not engraved. 5 Square (Illuminated Pushbutton) 1.0 4.4 ø 19 9 0. 13 2.6 Insert Square Lens Marking Plate ø 14 Square (Pilot Light) 21 1. [Square Pilot Lens] 1. Removing the Square Lens Insert the screwdriver into the recess of the lens and lightly push out the lens. Mushroom 21 Round 1.2 • Lens Structure and Marking Plate All square lens units are marking types. To engrave on the marking plate, remove the marking plate from the lens. • Marking Plate Engraving Area 22 Installing Buttons, Lenses, and Operators Note: The depth of the engraving must be within 0.5 mm. • Installing Round Lens and Waterproof Lens When installing or removing round lens of pilot lights and illuminated pushbuttons and waterproof lens of square pilot lights and illuminated pushbuttons, press the rubber part of the contact block removal tool onto the lens or waterproof lens for secure tightening and easy removal. TW_EP1070.book Page 39 Wednesday, January 19, 2005 10:49 AM TW Series Instructions ø22 Instructions • Installation of Selector Operators 1. The shaft of each selector or illuminated selector switch has a recess to identify in which direction to install the operator. Align the operator with the recess and press in the operator. 2. Press color insert (non-illuminated type) into the operator. The color insert retains the operator. • Removing the Operator Recess Flat screwdriver Color insert Recess 1.Removing the Color Insert Insert a flat screwdriver into the recess of the color insert. Turn the screwdriver to push out the insert from the operator Press in 2.Removing the Operator (Non-illuminated) Push the operator sideways as shown in the left photo to remove the operator. Press in Illuminated Selector Switch Selector Switch (non-illuminated) 2-Position, 90º 3-Position, 45º 4-Position, 45º 5-Position, 30º 1 1 2 3 1 0 2 2 1 2 3 4 5 4 Recess Flat screwdriver 3.Removing the Operator (Illuminated) Insert a flat screwdriver into the recess of the operator and turn the screwdriver to remove the operator. [Example] 1 0 1 2 1 0 0 2 2 Standard Position The non-illuminated operators can be installed in positions other than the standard position as shown above. Removing Contact Blocks, Transformers and Full Voltage Adapters Insert the end of the contact block removal tool into the snap-fit latch of the contact block (or transformer, full-voltage adapter) and pull the tool as shown below. Pull Collective Mounting When mounting the units closely in a horizontal row on 30mm centers, use optional barriers to prevent interconnection between adjoining terminals. The barriers can be attached simply by pressing them onto the sides of contact blocks. 30 30 Barrier (HW-VL1) Tightening Torque for Terminal Screws Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3 N·m 39 TW_Instructions Page 40 Tuesday, February 22, 2005 10:21 AM ø22 TW Series Instructions Installation of LED Illuminated Units 1. Note the polarity for wiring when connecting to DC-DC converter unit. Terminal No. X1 X2 Polarity Positive Negative 2. Transformer type units are recommended for use in areas subjected to noise. 3. Notes for Pure White LED Lamps • Do not use the pure white LED outdoors, otherwise it will lead to the degradation of brightness and color. Do not remove or apply shock to the cap on the pure white LED lamp, otherwise it may break or damage the cap. • For the pure white LED, use a white lens. The illumination color will be dull if a different color is used. Notes on LED Illuminated Units LED lamps consist of semiconductors. If the applied voltage exceeds the rated voltage, LED elements may deteriorate due to overheat, resulting in significant decrease in luminance, hue change, or failure of lighting. Also, if an extraneous noise, transient voltage, or transient current is applied to the circuit, similar effects may occur. When using LED lamps, observe the following instructions. • Rated Voltage The LED lamps are rated at 6V, 12V, or 24V AC/DC, and can be used within ±10% the rated voltage of either AC or DC. • DC Power 1. Switching power supply Regulated voltage from switching power supply is best suited. Make sure to use within the rated voltage of the LED lamp. 2. Rechargeable battery Note that the battery voltage may exceed the rated voltage of the LED lamp while the battery is being charged and immediately after the charging is complete. Be sure to use the LED lamp on a voltage of ±10% the rated voltage. 3. Full-wave rectification Since the LED lamp is AC/DC compatible, a diode bridge for rectification is not necessary. If the LED lamp is used on a full-wave rectification current through a diode bridge, the rectifier diodes will reduce the voltage, resulting in lower luminance. 4. Single-phase half-wave rectification This is not suitable for the power source of LED lamps. Use constant-voltage DC power. • Noise LED elements deteriorate due to extraneous noise, resulting in significant decrease in luminance, hue change, or failure of lighting. When such effects are anticipated, take a protection measure shown below, such as RC elements or a surge absorber. [Protection Example 1] For AC circuit LED with transformer C C LED with transformer LED Relay Ry coil or solenoid R LED R (Reference values) R: 120Ω C: 0.1µF [Protection Example 2] For DC circuit + (Reference values of the diode) Forward current: More than the Ry coil current Reverse withstand voltage: Ry coil current × 10 Relay Ry coil or solenoid LED Diode – • Countermeasures against Dim Lighting 1. Leakage currents through the transistors or a contact protection circuit may cause the LED lamp to illuminate dimly even when the output is off. 2. When the LED lamp is illuminated by a transistor output, take the following measure. [Circuit Example] Connect shunt resistor R in parallel with the LED lamp. R LED Io Io: Leakage current when the output is off R: Shunt resistor Specifications and other descriptions in this catalog are subject to change without notice. 7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan Tel: +81-6-6398-2571, Fax: +81-6-6392-9731 www.idec.com IDEC CORPORATION (USA) IDEC IZUMI ASIA PTE. LTD. 1175 Elko Drive, Sunnyvale, CA 94089-2209, USA Tel: +1-408-747-0550, Toll Free: (800) 262-IDEC, Fax: +1-408-744-9055 E-mail: opencontact@idec.com, www.idec.com No. 31, Tannery Lane #05-01, Dragon Land Building, Singapore 347788 Tel: +65-6746-1155, Fax: +65-6844-5995 E-mail: generalinfo@idecasia.com.sg IDEC CANADA LIMITED IDEC IZUMI (H.K.) CO., LTD. Unit 22-151, Brunel Road Mississauga, Ontario, L4Z 1X3, Canada Tel: +1-905-890-8561, Toll Free: (888) 317-4332, Fax: +1-905-890-8562 Unit 1505-07, DCH Commercial Centre No. 25, Westlands Road, Quarry Bay, Hong Kong Tel: +852-2803-8989, Fax: +852-2565-0171 E-mail: idec@idechk.com IDEC ELECTRONICS LIMITED Unit 2, Beechwood, Chineham Business Park, Basingstoke, Hampshire RG24 8WA, UK Tel: +44-1256-321000, Fax: +44-1256-327755 E-mail: idec@uk.idec.com IDEC ELEKTROTECHNIK GmbH Wendenstrasse 331, D-20537 Hamburg, Germany Tel: +49-40-25 30 54 10, Fax: +49-40-25 30 54 24 E-mail: service@idec.de, www.idec.de IDEC AUSTRALIA PTY. LTD. 2/3 Macro Court, Rowville, Victoria 3178, Australia Toll Free: 1-800-68-4332, Fax: +61-3-9763-3255 E-mail: sales@au.idec.com IDEC IZUMI (Shanghai) Co., Ltd. Room E, 15F, Majesty Building, No. 138 Pudong Avenue, Shanghai 200120, P.R.C. Tel: +86-21-5887-9181, Fax: +86-21-5887-8930 E-mail: idec@cn.idec.com IDEC TAIWAN CORPORATION 8F, No. 79, Hsin Tai Wu Road, Sec. 1, Hsi-Chih, Taipei County, Taiwan Tel: +886-2-2698-3929, Fax: +886-2-2698-3931 E-mail: service@idectwn.com.tw Cat. No. EP1070-0 JANUARY 2005 13DNP PRINTED IN JAPAN