Technical Specifications of Hybrid Solar UPS Brainy Solar PCU RATING 850VA/12VDC PV CHARGE CONTROLLER RATING 240Wp Model No. Brainy Type Technology Power device Wave form type Output Voltage in Volts (AC) Output frequency in Hz Efficiency Distortion (THD) Forced ventilation Nominal Input voltage (DC) Battery Low Voltage warning Battery Low Voltage cut off Load Reconnection Battery Reverse pole protection Short Circuit protection Over load Protection Over Load Shutdown Over Heating protection Single Phase Solar Power Conditioning Unit DSP Based PWM Technology IGBTs cum MOSFETs Sine wave 220 V ± 10 % 50 ± 1% Hz Typical 75% (80-100% Resistive Load) <5% on linear load Thru Cooling Fan 12V 10.7V±0.2V 10.5V±0.2V 14.0V+/-0.4V Dc Fuse Blown retry for 2 times & permanent out put OFF 150% for >10 Seconds permanent out put OFF >105°C Grid Mains Mode Grid I/P Range Solar Priority: Grid power connected to load when battery voltage ≤12.2V ±0.2 battery charging take place by grid power as same as specified changeover time (<10msec*) if grid is within the specified range (Factory Settable). Grid Priority: Grid power connected to load when battery voltage ≤13V ±0.2 battery charging take place by grid power as same as specified changeover time (<10msec*) if grid is within the specified range (Default Setting). Grid Charging Current (Tubular / SMF / LA) Charge End Voltage (Battery Boost & Float Charging Voltage) Change over time: Wide Window & Narrow Window Wide Window Grid low cut Grid low cut recovery Grid high cut Grid high cut recovery Narrow Window Grid low cut Grid low cut recovery Grid high cut Grid high cut recovery Solar Charge Controller Type Maximum I/P PV Voltage Solar Array Charging Current Imax. Bulk / Absorption Voltage Float Voltage Protection Automatic Charger Restart Time after High Current Solar Charge Controller to PV power connection time. Design service use Operating Temp. Storage Temp. Acoustic Noise @ 1metre Relative Humidity Size (WxDxH) ± 10mm 14A ± 2A* 14.4V (SMF, Tubular) / 14.0V (LA) +/-0.2V.(Grid charging stops when battery reaches float charging 13.6V+/-0.2V and PV power will be >5 to 8W then System transfer to backup mode as same as specified changeover time(Ups <15 msec. or W-Ups <40msec. **). Mains to Inverter < 40 milliseconds Mains to Inverter <15 milliseconds 105VAC ±10V 120VAC ±10V 285VAC ±10V 275VAC ±10V 185VAC ±10V 190VAC ±10V 265VAC ±10V 255VAC ±10V Series Regulator, PWM based 25V Max. for 12V System Single Array 14A (Max.) 14.5V+0.2V 14.0V+0.2V Over Current, Battery over Charge, PV/Battery Reverse Polarity, Reverse Current Flow, 3.5 Minutes < 10sec. Indoor 0°C to + 55°C 0°C to + 55°C < 60dB 0-95% Non-Condensing 308x343x170 Weight (approx. in Kg) ± 400gm 10Kg Note: Specifications are subject to change without any prior notice. As on September 2013