Hipulse UPS System
Nominal Rating [kVA] (0.8 pf)
Rectifier Type
80
6p
120
12p
6p
160
12p
6p
200
12p
6p
300
12p
6p
400
12p
6p
12p
500
600
800
12p
12p
12p
1050 DEARBORN DRIVE
P.O.BOX 29186
COLUMBUS,OHIO 43229
TEL: 800.877.9222 (U.S.& C ANADA ONLY )
TEL: 614.888.0246 (OUTSIDE U.S)
FAX: 614.841.6022
Physical Characteristics
Depth [mm]
Width [mm]
875
Height [mm]
Weight [kg]
1000
900 1300 1250 1890 1250 1890 1250 1890 1640 2280 2460 2460 3200 3200 4400
1900
750 1120 1000 1475 1200 1725 1350 2000 1850 2540 2400 3100 4200 4500 5050
Input
Voltage
380 / 400 / 415V (+10 / - 15 % ) - 3Ph - 4w
Frequency
ITHD
Power Factor
50 or 60 Hz +/-5%
4 - 10 % with optional input filter
0.90 - 0.94 with optional input filter
Output
Voltage
380 / 400 / 415V - 3Ph - 4w
Voltage Stability
- 100% Load Step
5%
Frequency
1%
- Synchronised with the bypass supply
- Auto-synchronised
- 3 Ph
110% for 60 minutes, 125% for 10 minutes, 135-150% for 1 minute
- 1 Ph
200% for 30 seconds
Short circuit current from inverter
- 1 Ph
Voltage Distortion With Linear Load
1.5 In for 5 seconds (in accordance with EN 50091 - 1 - 1)
2.9 In for 5 seconds
2.2 In for 5 seconds
<1%
Voltage Distortion With 100%
Non - Linear Load
< 3% Ph / Ph, <5% Ph / N (distorted load as per EN50091 - 3)
Max. Deliverable Power
With Non-Linear Load (CF = 3:1)
100%
Max Unbalanced Load
100%
Voltage Displacement With
100% Unbalanced Load
1o el
120o
Output Voltage Dissymmetry
With 100% Unbalanced Load
2%
Standards and Approvals
Safety / EMC / Design
CEI EN 50091 - 1 - 1/ EN 50091 - 2/ ENV 50091 - 3
European Directives
73/23/EEC and 89/336/EEC
EMERSON NETWORK POWER (CHINA) LTD
BANXUEGANG INDUSTRIAL AREA, LONGGANG DISTRICT, SHENZHEN 518129, CHINA
TEL: 86-755-28780808 FAX: 86-755-28788220
EMERSON NETWORK POWER (INDONESIA)
WISMA PONDOK INDAH 1ST FLOOR, JL. SULTAN ISKANDAR MUDA V TA, JAKARTA 12310, INDONESIA
TEL: 62-21-7519399 FAX: 62-21-7519388
0.1%
Overload capacity from inverter at nominal voltage
- 3 Ph
COUNTRY OFFICES
EMERSON NETWORK POWER (AUSTRALIA) PTY LTD
BLOCK P, REGENTS PARK ESTATE, 391 PARK ROAD, REGENTS PARK, SYDNEY, NSW 2143,
AUSTRALIA
TEL: 61-1300367686 FAX: 61-2-97438737
EMERSON NETWORK POWER (INDIA) PRIVATE LTD
PLOT NO. C-20, ROAD NO. 19, WAGLE INDUSTRIAL ESTATE, THANE (WEST), MAHARASHTRA
400604, INDIA
TEL: 91-22-25807000/2388 FAX: 91-22-25828358
50 or 60 Hz
Frequency Stability
ASIA PACIFIC HEADQUARTERS
EMERSON NETWORK POWER ASIA PACIFIC
23/F, ALLIED KAJIMA BUILDING, 138 GLOUCESTER ROAD, WANCHAI, HONG KONG
TEL: 852-25722201 FAX: 852-28029250
EMERSON NETWORK POWER (HONG KONG) LTD
23/F, ALLIED KAJIMA BUILDING, 138 GLOUCESTER ROAD, WANCHAI, HONG KONG
TEL: 852-25722201 FAX: 852-28310114
1%
- steady State
Emerson Net work Power AP Office Locations
CE mark
While every precaution has been taken to ensure accuracy and
completeness in this brochure, Liebert Corporation assumes no
responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions.
c 2002 Liebert Corporation. All rights reserved throughout the
world. Specifications subject to change without notice.
EMERSON NETWORK POWER (KOREA)
8TH FL. HONGIK UNIVERSITY KANGNAM ART CENTER, 51-12 BANPO-DONG, SEOCHO-GU, SEOUL
137 044, KOREA
TEL: 82-2-34831500 FAX: 82-2-5927883
EMERSON NETWORK POWER DIVISION / EMERSON JAPAN LTD
NEW PIER TAKESHIBA, SOUTH TOWER 7F, 1-16-1 KAIGAN, MINATO-KU, TOKYO 105-0022, JAPAN
TEL: 81-3-54038594 FAX: 81-3-54032924
EMERSON NETWORK POWER (MALAYSIA) SDN BHD
WISMA GLOMAC 3, BLOCK C, 7TH FLOOR, JALAN SS 7/19, KELANA JAYA, 47301 PETALING JAYA,
SELANGOR DARUL EHSAN, MALAYSIA
TEL: 60-3-78036868 FAX: 60-3-78032878
EMERSON NETWORK POWER (PHILIPPINES), INC.
33/F, ORIENT SQUARE BLDG, EMERALD AVENUE, ORTIGAS CENTER, PASIG CITY, PHILIPPINES
TEL: 63-2-6872617 FAX: 63-2-6872891
EMERSON NETWORK POWER (SINGAPORE) PTE LTD
896 DUNEARN ROAD #03-08, SIME DARBY CENTRE, SINGAPORE 589472, R.O.S.
TEL: 65-64672211 FAX: 65-64670130
EMERSON NETWORK POWER (TAIWAN) LTD
11F, 141 JEN AI ROAD, SECTION 3, TAIPEI 106, TAIWAN, R.O.C.
TEL: 886-2-87713655 FAX: 886-2-87717297
EMERSON NETWORK POWER (THAILAND) CO LTD
123 SUNTOWERS BLDG.-B, 22ND FL, VIBHAVADI-RANGSIT ROAD, LADYAO, CHATUCHAK, BANGKOK
10900, THAILAND
TEL: 66-2-6178260 FAX: 66-2-6178277 TO 78
LIEBERT WEB SITE
http://www.liebert.com
EMERSON NETWORK POWER WEB SITE
All names referred to are trademarks or registered trademarks
of their respective owners.
http://www.emersonnetwork-ap.com
AP02POW61CNR1
Liebert is a division of
www.liebert.com
Hi
puls
e UPS ( 80 - 800 kV
A)
Hip
ulse
kVA)
Power Availability
UPS FOR THE DIGITAL WORLD
Reliability, Availability, Scalability, Redundancy,
User-friendliness and Maintainability,
whichever value you need,
Hipulse addresses them all efficiently and effectively
HIPULSE
UPS FOR THE DIGITAL WORLD,
YOUR POWER QUALITY PARTNER
From reliability to availability, from scalability to redundancy, from user-friendliness to maintainability, from parallelibility to
connectivity, from investment protection to lower cost of ownership, whichever value you need, Hipulse addresses them all
efficiently and effectively.
2
Hipulse is carefully designed to maximize the “availability” of your critical loads to ensure that your business is protected to the
extent possible against power failure and/or power quality problems. This is the prime objective for which the Hipulse is built.
Besides this, Hipulse is designed to address many other “customer values”.
Major Applications
• Information Technology
- Data Centers
- Servers (LAN, WAN, MAN, ERP, e-mail, web and others)
- Networking
• Telecommunication
- Mobile (2G, 2.5G, 3G)
- Paging
- Fixed (including WLL)
• Industrial Automation
- Process (including instrumentation)
- Motion (digital drives & robotics)
• Transport Automation
- Airport automation and flight booking
- Others including railways & road transport automation
& ticket booking
• Banking, Insurance and Financial Services
• Software Development Houses / Software
Technology Parks (STP)
• Building Automation
- Access Control
- Security System
- Fire Alarm System
- Emergency Lighting
- Other Critical Applications
• Medical Diagnostics
- Magneto Resonant Imaging
- CT Scanning
- CathLab
• Satellite
- Uplinking
- Earth Stations
Customer needs have been captured and understood for various application areas in different geographical territories. Thereafter,
customer needs analysis has been done before providing inputs to our design team. Our studies explain to you high investment
value brought by Hipulse UPS.
Application and Business Needs
• On-Line Double Conversion
9% in the static bypass
• IGBT-based PWM Inverter
• Selectable timer for boost charging duration of the
• Wide input voltage tolerance (+10/-15%)
• Wide input frequency tolerance (
• Adjustable frequency synchronisation window up to
5%)
• Temperature-compensated battery charging (optional)
battery (15 steps with each step of 1 hour)
• Provision of automatic battery circuit breaker instead of
using conventional isolator in the DC path
• Automatic battery testing
• Field protocols ModBus / Jbus
• Common battery sharing kit (optional) with 1+1 configuration
• Network protocols SNMP/HTTP NIC Card
considering common battery bank
• High overload capability of static bypass (14 times for
10 milliseconds and 10 times for 100 milliseconds)
• Capability to handle:
- High crest factor loads
- 100% non-linear loads
- 100% unbalanced loads
• Built-in maintenance bypass (Single and 1+N Models)
• Wrap-around Maintenance bypass (optional)
- Wall-mounted RAM (Remote Alarm Monitor) Box
• Over-load capability of the UPS:
- 110% full-load for 60 minutes
- 125% full-load for 10 minutes
- 135-150% full-load for 60 seconds
• Achieving parallel redundancy with 1+N configuration
(upto as high as 6 modules) without using any kind of
centralised Main Static Switch (MSS)
• Compact footprint
• Front access for spares replacement and preventive
maintenance
• Modular design of inverter bridge for higher rated UPS
modules like 600 & 800 kVA
• UPS modules in Dual Bus configuration using optional
Investment Protection Needs
• Temperature-compensated battery charging (optional)
• Protection against deep discharge of battery
• Battery circuit breaker instead of using Ac isolator
HiSync on the Upstream (with UPS), HiSwitch in the
• Short-circuit proof inverter
down-stream (after UPS) and load-end SmartSwitches
• Back-feed protection
• Provision to use any type of battery : Wet cells (Tubular
• Choice of any type of battery like wet or VRLA or Ni-Cd
or Plant ), Valve Regulated Lead Acid (VRLA) / Maintenance
• Choice between 6 or 12-pulse rectifier (upto 400kVA)
free and Nickel Cadmium
• Choice between input tuned filter or no filter
• Field settability of end-cell voltage of the battery
3
Selected Configurations
Hipulse can be scaled upto as high as 6 modules using any of the following configurations to achieve either scalability or
redundancy of desired percentage
-1+N configuration without any kind of centralised static switch
-Centralised configuration by using centralised static switch called MSS (Main Static Switch)
-Some more configurations are explained further in this brochure
-For other configurations please contact our nearest sales office/representative
4
Hot S
d-b
yC
onfigur
ati
on
Sttan
and
-by
Co
nfigura
tio
• Feed one (Priority) or two (Priority &
Normal) load banks depending on the
application need
Bypass Mains
• Increase the reliability of the priority load
• Increase the maintainability
Normal Load
Normal Mains
• Easy connection
• Can be implemented in the existing
installation regardless of the UPS size,
Priority Load
Normal Mains
the generation of (device or technology
or philosophy of control) and the
manufacturer
1+N Configuration WITHOUT
Centralised Bypass called Main Static
Bypass Mains
Switch (MSS)
• Up to six modules in parallel
• Increase the system reliability
Normal
Mains
Normal
Mains
Normal
Mains
• Increase the availability of quality power
following the load demand even if it
was not forecasted or planned at the
beginning of the project: ease of technoeconomic expandability
• Increase the maintainability
• The total load is less than or equal to
UPS 1
UPS 2
the rating of the single UPS (depending
on the desired redundancy level) The
load is shared between all modules
LOAD
UPS 6
Multimodule Configuration
WITH Centralised Bypass called
Normal Mains
Normal Mains
Normal Mains
Normal Mains
Main Static Switch (MSS)
• Up to six modules in parallel
• Increase the system reliability
• Increase the power availability
up to the MSS capacity
• Increase the maintainability
5
• The total load is less than or equal
to the rating of the single UPS
UPS 1
UPS2
UPS6
MSS
(depending on the desired
redundancy level). The load is
LOAD
shared between all modules
Bypass
Mains
Bypass
Mains
Dual Bus System with HiSync
Normal
Mains
Normal
Mains
UPS 1
UPS6
UPS1
and HiSwitch/STS
• Provide supply to the loads from
two independent power sources
• The two may be different in terms
of power rating and redundancy
HiSynch
• The two BUS outputs are in
synchronism between them
• Automatic transfer of the load
between the two sources in
HiSwitch 1
case of fault using HiSwitch
• Increase
dramatically the
Load 1
maintainability and reliability
HiSwitch 2
Load 2
Normal
Mains
UPS 6
Power Communication Options
When you choose the best system to protect your mission critical applications, part of your decision will be driven by the
software and communication options. Hipulse has been designed with the customer in mind. This is why we have built a
wide range of sophisticated optional software and communication solutions for Hipulse.
The most extensive list of optional communication solutions for Hipulse UPS Systems!
• Control through Building Management Systems via Modbus and Jbus protocols
• Web-enabled Monitoring and Management through SNMP protocols with OpenComms NIC card
• Network Management Systems ready (HP OpenView, CA Unicenter, Novell Managewise, etc.)
• Software Solutions
6
- Liebert UPS Monitoring Software
- HPAC and UPS supervision
- Facility wide monitoring (SiteScan)
- Shutdown software for your computer equipment
• Simultaneous monitoring via different protocols
• Emerson Power Quality Monitoring solutions
• Wall-mounted RAM (Remote Alarm Monitor) Box
7
Selected Power Options
Power Walk-in for Multimodule System
In
put C
ur
ar
moni
edu
on
Inp
Cur
urrrent H
Har
arm
onicc (THDi) R
Redu
educc ti
tion
• The module power walk-in is standard. This option can be
• 12-pulse rectifier version.
for the module restart delay after the mains return. This
• Wide range of additional solution to reduce the THDi
is very useful for applications with motor generator at the
around 4%. Most of them without any additional system
footprint.
Input Isolation Transformer
• Wide range of solutions specially designed for handling
current harmonic on bypass at different stages.
• Available for rectifier and/or bypass supply.
input.
HiSync
• This ensures the synchronisation of outputs of two
independent UPS systems.
• This allows automatic transfer of load between the two
sources.
Protection Degree (IP) For Hipulse Enclosure
HiSwitch/Statistic Switch
• To address stressed environmental conditions, UPS with
• This allows critical load to be transferred between two
higher than IP20 degree of protection can be made available
independent, synchronised AC power sources without any
for most of the kVA ratings of Hipulse.
risk of load disturbances.
DC Ground Fault Indication
TVSS
• This provides indication of occurrence of battery ground
• This is a Transient Voltage Surge Suppressor.
fault problems.
Top Cable Entry
• This is available for a wide range of our Hipulse ratings.
• This offers protection from damaging transients and
electrical line noises.
• This is normally connected at the bypass path of Hipulse
or inside the HiSwitch as an optional item.