WE HELP YOU GE T I T RIG HT - R I G H T F R O M T H E S TA R T. Hi puls e UPS ( 80 - 800 kV A) Hip ulse kVA) Power Availability L I E B E R T C O R P O R A T IO N General Features Hipulse UPS System Nominal Rating [kVA] (0.8 pf) Rectifier Type 80 6p 120 12p 6p 160 12p 6p 200 12p 6p 300 12p 6p 400 12p 6p 12p 500 600 800 12p 12p 12p 1050 DEARBORN DRIVE P.O.BOX 29186 COLUMBUS,OHIO 43229 TEL: 800.877.9222 (U.S.& C ANADA ONLY ) TEL: 614.888.0246 (OUTSIDE U.S) FAX: 614.841.6022 Physical Characteristics Depth [mm] Width [mm] 875 Height [mm] Weight [kg] 1000 900 1300 1250 1890 1250 1890 1250 1890 1640 2280 2460 2460 3200 3200 4400 1900 750 1120 1000 1475 1200 1725 1350 2000 1850 2540 2400 3100 4200 4500 5050 Input Voltage 380 / 400 / 415V (+10 / - 15 % ) - 3Ph - 4w Frequency ITHD Power Factor 50 or 60 Hz +/-5% 4 - 10 % with optional input filter 0.90 - 0.94 with optional input filter Output Voltage 380 / 400 / 415V - 3Ph - 4w Voltage Stability - 100% Load Step 5% Frequency 1% - Synchronised with the bypass supply - Auto-synchronised - 3 Ph 110% for 60 minutes, 125% for 10 minutes, 135-150% for 1 minute - 1 Ph 200% for 30 seconds Short circuit current from inverter - 1 Ph Voltage Distortion With Linear Load 1.5 In for 5 seconds (in accordance with EN 50091 - 1 - 1) 2.9 In for 5 seconds 2.2 In for 5 seconds <1% Voltage Distortion With 100% Non - Linear Load < 3% Ph / Ph, <5% Ph / N (distorted load as per EN50091 - 3) Max. Deliverable Power With Non-Linear Load (CF = 3:1) 100% Max Unbalanced Load 100% Voltage Displacement With 100% Unbalanced Load 1o el 120o Output Voltage Dissymmetry With 100% Unbalanced Load 2% Standards and Approvals Safety / EMC / Design CEI EN 50091 - 1 - 1/ EN 50091 - 2/ ENV 50091 - 3 European Directives 73/23/EEC and 89/336/EEC EMERSON NETWORK POWER (CHINA) LTD BANXUEGANG INDUSTRIAL AREA, LONGGANG DISTRICT, SHENZHEN 518129, CHINA TEL: 86-755-28780808 FAX: 86-755-28788220 EMERSON NETWORK POWER (INDONESIA) WISMA PONDOK INDAH 1ST FLOOR, JL. SULTAN ISKANDAR MUDA V TA, JAKARTA 12310, INDONESIA TEL: 62-21-7519399 FAX: 62-21-7519388 0.1% Overload capacity from inverter at nominal voltage - 3 Ph COUNTRY OFFICES EMERSON NETWORK POWER (AUSTRALIA) PTY LTD BLOCK P, REGENTS PARK ESTATE, 391 PARK ROAD, REGENTS PARK, SYDNEY, NSW 2143, AUSTRALIA TEL: 61-1300367686 FAX: 61-2-97438737 EMERSON NETWORK POWER (INDIA) PRIVATE LTD PLOT NO. C-20, ROAD NO. 19, WAGLE INDUSTRIAL ESTATE, THANE (WEST), MAHARASHTRA 400604, INDIA TEL: 91-22-25807000/2388 FAX: 91-22-25828358 50 or 60 Hz Frequency Stability ASIA PACIFIC HEADQUARTERS EMERSON NETWORK POWER ASIA PACIFIC 23/F, ALLIED KAJIMA BUILDING, 138 GLOUCESTER ROAD, WANCHAI, HONG KONG TEL: 852-25722201 FAX: 852-28029250 EMERSON NETWORK POWER (HONG KONG) LTD 23/F, ALLIED KAJIMA BUILDING, 138 GLOUCESTER ROAD, WANCHAI, HONG KONG TEL: 852-25722201 FAX: 852-28310114 1% - steady State Emerson Net work Power AP Office Locations CE mark While every precaution has been taken to ensure accuracy and completeness in this brochure, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. c 2002 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. EMERSON NETWORK POWER (KOREA) 8TH FL. HONGIK UNIVERSITY KANGNAM ART CENTER, 51-12 BANPO-DONG, SEOCHO-GU, SEOUL 137 044, KOREA TEL: 82-2-34831500 FAX: 82-2-5927883 EMERSON NETWORK POWER DIVISION / EMERSON JAPAN LTD NEW PIER TAKESHIBA, SOUTH TOWER 7F, 1-16-1 KAIGAN, MINATO-KU, TOKYO 105-0022, JAPAN TEL: 81-3-54038594 FAX: 81-3-54032924 EMERSON NETWORK POWER (MALAYSIA) SDN BHD WISMA GLOMAC 3, BLOCK C, 7TH FLOOR, JALAN SS 7/19, KELANA JAYA, 47301 PETALING JAYA, SELANGOR DARUL EHSAN, MALAYSIA TEL: 60-3-78036868 FAX: 60-3-78032878 EMERSON NETWORK POWER (PHILIPPINES), INC. 33/F, ORIENT SQUARE BLDG, EMERALD AVENUE, ORTIGAS CENTER, PASIG CITY, PHILIPPINES TEL: 63-2-6872617 FAX: 63-2-6872891 EMERSON NETWORK POWER (SINGAPORE) PTE LTD 896 DUNEARN ROAD #03-08, SIME DARBY CENTRE, SINGAPORE 589472, R.O.S. TEL: 65-64672211 FAX: 65-64670130 EMERSON NETWORK POWER (TAIWAN) LTD 11F, 141 JEN AI ROAD, SECTION 3, TAIPEI 106, TAIWAN, R.O.C. TEL: 886-2-87713655 FAX: 886-2-87717297 EMERSON NETWORK POWER (THAILAND) CO LTD 123 SUNTOWERS BLDG.-B, 22ND FL, VIBHAVADI-RANGSIT ROAD, LADYAO, CHATUCHAK, BANGKOK 10900, THAILAND TEL: 66-2-6178260 FAX: 66-2-6178277 TO 78 LIEBERT WEB SITE http://www.liebert.com EMERSON NETWORK POWER WEB SITE All names referred to are trademarks or registered trademarks of their respective owners. http://www.emersonnetwork-ap.com AP02POW61CNR1 Liebert is a division of www.liebert.com Hi puls e UPS ( 80 - 800 kV A) Hip ulse kVA) Power Availability UPS FOR THE DIGITAL WORLD Reliability, Availability, Scalability, Redundancy, User-friendliness and Maintainability, whichever value you need, Hipulse addresses them all efficiently and effectively HIPULSE UPS FOR THE DIGITAL WORLD, YOUR POWER QUALITY PARTNER From reliability to availability, from scalability to redundancy, from user-friendliness to maintainability, from parallelibility to connectivity, from investment protection to lower cost of ownership, whichever value you need, Hipulse addresses them all efficiently and effectively. 2 Hipulse is carefully designed to maximize the “availability” of your critical loads to ensure that your business is protected to the extent possible against power failure and/or power quality problems. This is the prime objective for which the Hipulse is built. Besides this, Hipulse is designed to address many other “customer values”. Major Applications • Information Technology - Data Centers - Servers (LAN, WAN, MAN, ERP, e-mail, web and others) - Networking • Telecommunication - Mobile (2G, 2.5G, 3G) - Paging - Fixed (including WLL) • Industrial Automation - Process (including instrumentation) - Motion (digital drives & robotics) • Transport Automation - Airport automation and flight booking - Others including railways & road transport automation & ticket booking • Banking, Insurance and Financial Services • Software Development Houses / Software Technology Parks (STP) • Building Automation - Access Control - Security System - Fire Alarm System - Emergency Lighting - Other Critical Applications • Medical Diagnostics - Magneto Resonant Imaging - CT Scanning - CathLab • Satellite - Uplinking - Earth Stations Customer needs have been captured and understood for various application areas in different geographical territories. Thereafter, customer needs analysis has been done before providing inputs to our design team. Our studies explain to you high investment value brought by Hipulse UPS. Application and Business Needs • On-Line Double Conversion 9% in the static bypass • IGBT-based PWM Inverter • Selectable timer for boost charging duration of the • Wide input voltage tolerance (+10/-15%) • Wide input frequency tolerance ( • Adjustable frequency synchronisation window up to 5%) • Temperature-compensated battery charging (optional) battery (15 steps with each step of 1 hour) • Provision of automatic battery circuit breaker instead of using conventional isolator in the DC path • Automatic battery testing • Field protocols ModBus / Jbus • Common battery sharing kit (optional) with 1+1 configuration • Network protocols SNMP/HTTP NIC Card considering common battery bank • High overload capability of static bypass (14 times for 10 milliseconds and 10 times for 100 milliseconds) • Capability to handle: - High crest factor loads - 100% non-linear loads - 100% unbalanced loads • Built-in maintenance bypass (Single and 1+N Models) • Wrap-around Maintenance bypass (optional) - Wall-mounted RAM (Remote Alarm Monitor) Box • Over-load capability of the UPS: - 110% full-load for 60 minutes - 125% full-load for 10 minutes - 135-150% full-load for 60 seconds • Achieving parallel redundancy with 1+N configuration (upto as high as 6 modules) without using any kind of centralised Main Static Switch (MSS) • Compact footprint • Front access for spares replacement and preventive maintenance • Modular design of inverter bridge for higher rated UPS modules like 600 & 800 kVA • UPS modules in Dual Bus configuration using optional Investment Protection Needs • Temperature-compensated battery charging (optional) • Protection against deep discharge of battery • Battery circuit breaker instead of using Ac isolator HiSync on the Upstream (with UPS), HiSwitch in the • Short-circuit proof inverter down-stream (after UPS) and load-end SmartSwitches • Back-feed protection • Provision to use any type of battery : Wet cells (Tubular • Choice of any type of battery like wet or VRLA or Ni-Cd or Plant ), Valve Regulated Lead Acid (VRLA) / Maintenance • Choice between 6 or 12-pulse rectifier (upto 400kVA) free and Nickel Cadmium • Choice between input tuned filter or no filter • Field settability of end-cell voltage of the battery 3 Selected Configurations Hipulse can be scaled upto as high as 6 modules using any of the following configurations to achieve either scalability or redundancy of desired percentage -1+N configuration without any kind of centralised static switch -Centralised configuration by using centralised static switch called MSS (Main Static Switch) -Some more configurations are explained further in this brochure -For other configurations please contact our nearest sales office/representative 4 Hot S d-b yC onfigur ati on Sttan and -by Co nfigura tio • Feed one (Priority) or two (Priority & Normal) load banks depending on the application need Bypass Mains • Increase the reliability of the priority load • Increase the maintainability Normal Load Normal Mains • Easy connection • Can be implemented in the existing installation regardless of the UPS size, Priority Load Normal Mains the generation of (device or technology or philosophy of control) and the manufacturer 1+N Configuration WITHOUT Centralised Bypass called Main Static Bypass Mains Switch (MSS) • Up to six modules in parallel • Increase the system reliability Normal Mains Normal Mains Normal Mains • Increase the availability of quality power following the load demand even if it was not forecasted or planned at the beginning of the project: ease of technoeconomic expandability • Increase the maintainability • The total load is less than or equal to UPS 1 UPS 2 the rating of the single UPS (depending on the desired redundancy level) The load is shared between all modules LOAD UPS 6 Multimodule Configuration WITH Centralised Bypass called Normal Mains Normal Mains Normal Mains Normal Mains Main Static Switch (MSS) • Up to six modules in parallel • Increase the system reliability • Increase the power availability up to the MSS capacity • Increase the maintainability 5 • The total load is less than or equal to the rating of the single UPS UPS 1 UPS2 UPS6 MSS (depending on the desired redundancy level). The load is LOAD shared between all modules Bypass Mains Bypass Mains Dual Bus System with HiSync Normal Mains Normal Mains UPS 1 UPS6 UPS1 and HiSwitch/STS • Provide supply to the loads from two independent power sources • The two may be different in terms of power rating and redundancy HiSynch • The two BUS outputs are in synchronism between them • Automatic transfer of the load between the two sources in HiSwitch 1 case of fault using HiSwitch • Increase dramatically the Load 1 maintainability and reliability HiSwitch 2 Load 2 Normal Mains UPS 6 Power Communication Options When you choose the best system to protect your mission critical applications, part of your decision will be driven by the software and communication options. Hipulse has been designed with the customer in mind. This is why we have built a wide range of sophisticated optional software and communication solutions for Hipulse. The most extensive list of optional communication solutions for Hipulse UPS Systems! • Control through Building Management Systems via Modbus and Jbus protocols • Web-enabled Monitoring and Management through SNMP protocols with OpenComms NIC card • Network Management Systems ready (HP OpenView, CA Unicenter, Novell Managewise, etc.) • Software Solutions 6 - Liebert UPS Monitoring Software - HPAC and UPS supervision - Facility wide monitoring (SiteScan) - Shutdown software for your computer equipment • Simultaneous monitoring via different protocols • Emerson Power Quality Monitoring solutions • Wall-mounted RAM (Remote Alarm Monitor) Box 7 Selected Power Options Power Walk-in for Multimodule System In put C ur ar moni edu on Inp Cur urrrent H Har arm onicc (THDi) R Redu educc ti tion • The module power walk-in is standard. This option can be • 12-pulse rectifier version. for the module restart delay after the mains return. This • Wide range of additional solution to reduce the THDi is very useful for applications with motor generator at the around 4%. Most of them without any additional system footprint. Input Isolation Transformer • Wide range of solutions specially designed for handling current harmonic on bypass at different stages. • Available for rectifier and/or bypass supply. input. HiSync • This ensures the synchronisation of outputs of two independent UPS systems. • This allows automatic transfer of load between the two sources. Protection Degree (IP) For Hipulse Enclosure HiSwitch/Statistic Switch • To address stressed environmental conditions, UPS with • This allows critical load to be transferred between two higher than IP20 degree of protection can be made available independent, synchronised AC power sources without any for most of the kVA ratings of Hipulse. risk of load disturbances. DC Ground Fault Indication TVSS • This provides indication of occurrence of battery ground • This is a Transient Voltage Surge Suppressor. fault problems. Top Cable Entry • This is available for a wide range of our Hipulse ratings. • This offers protection from damaging transients and electrical line noises. • This is normally connected at the bypass path of Hipulse or inside the HiSwitch as an optional item.