G7L Power Relay A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops • No contact chattering for momentary voltage drops up to 50% of rated voltage. • Wide-range AC-activated coil that handles 100 to 120 or 200 to 240 VAC at either 50 or 60 Hz. • Miniature size for maximum switching power, particularly for inductive loads. • Flame-resistance materials (UL94V-0-qualifying) used for all insulation material. • Quick-connect, screw, and PCB terminals, and DIN track mounting available. • Conforms to UL, CSA, TUV and meets IEC950. • Safety design with contact gap of 3 mm. G 7 L RoHS Compliant ■Application Examples ■Model Number Legend G 7 L -@ @ -@ @ @ —— ——— 1 2 3 4 5 1. Number of Poles 3. Terminal Shape T: Quick connect 1: 1 pole terminals (#250) 2: 2 poles B: Screw terminals 2. Contact Form P: PCB terminals A: @PST-NO 4. Mounting Construction Blank: E-bracket UB : Upper bracket 5. Special Functions J : With test button ■Model Configuration Terminal Classification E-bracket mounting (E-bracket is sold separately) Upper bracket mounting − With test button − With test button PCB mounting − Contact form SPST-NO DPST-NO SPST-NO DPST-NO SPST-NO DPST-NO SPST-NO DPST-NO SPST-NO DPST-NO Quick-connect terminals G7L-1A-T G7L-2A-T G7L-1A-TJ G7L-2A-TJ G7L-1A-TUB G7L-2A-TUB G7L-1A-TUBJ G7L-2A-TUBJ − − Screw terminals G7L-1A-B G7L-2A-B G7L-1A-BJ G7L-2A-BJ G7L-1A-BUB G7L-2A-BUB G7L-1A-BUBJ G7L-2A-BUBJ − − PCB terminals − − − − − − − − G7L-1A-P G7L-2A-P Compressors for air conditioners and heater switching controllers. Switching controllers for power tools or motors. Power controllers for water heaters. Power controllers for dryers. Lamp controls, motor drivers, and power supply switching in copy machines, facsimile machines, and other office equipment. Lighting controllers. Power controllers for packers or food processing equipment. Magnetron control in microwaves. Power controllers for Uninterruptible Power Supply (UPS) ■List of E-bracket Mounting Models Mounting E-brackets Terminal Quickconnect terminals Screw terminals Contact form SPST-NO DPST-NO SPST-NO DPST-NO Model G7L-1A-T G7L-1A-TJ G7L-2A-T G7L-2A-TJ G7L-1A-B G7L-1A-BJ G7L-2A-B G7L-2A-BJ Test button − With test button − With test button − With test button − With test button DIN Track Mounting Adapter Front-connecting Socket − − − − Note. E-bracket (R99-07), adaptor (P7LF-D), surface connection socket (P7LF-06) are sold separately. 1 G7L Power Relay ■Ordering Information E-bracket/Adapter/Socket Mounting E-bracket/Adapter/Socket Mounting (with test button) Quick-connect Terminal Number of poles Model 1 pole G7L-1A-T 2 poles G7L-2A-T Quick-connect Terminal Rated coil voltage Minimum packing unit AC: 12, 24, 100/120, 200/240 DC: 6, 12, 24, 48, 100 AC: 12, 24, 50, 100/120, 200/240 DC: 6, 12, 24, 48, 100 1 pole G7L-1A-TUB 2 poles G7L-2A-TUB Rated coil voltage AC: 12, 24, 100/120, 200/240 DC: 6, 12, 24, 48, 100 AC: 12, 24, 50, 100/120, 200/240 1 pole G7L-1A-B G7L-1A-BUB 2 poles G7L-2A-BUB Rated coil voltage AC: 12, 24, 100/120, 200/240 DC: 6, 12, 24, 48, 100 Model 1 pole G7L-1A-P 2 poles G7L-2A-P AC: 24, 100/120, 200/240 20 pcs./tray DC: 6, 12, 24, 48, 100 1 pole G7L-1A-TUBJ Rated coil voltage G7L-2A-TUBJ Minimum packing unit AC: 24, 100/120, 200/240 DC: 6, 12, 24, 48, 100 AC: 12, 24, 50, 100/120, 200/240 20 pcs./tray DC: 6, 12, 24, 48, 100 Number of poles Model 1 pole G7L-1A-BJ Rated coil voltage G7L-2A-BJ Minimum packing unit AC: 12, 24, 100/120, 200/240 DC: 12, 24 AC: 24, 100/120, 200/240 20 pcs./tray DC: 12, 24, 48, 100 Upper Bracket Mounting (with test button) Screw Terminal Rated coil voltage Minimum packing unit AC: 24, 100/120, 200/240 DC: 6, 12, 24, 48, 100 AC: 12, 24, 50, 100/120, 200/240 DC: 6, 12, 24, 48, 100 Rated coil voltage Minimum packing unit AC: 100/120, 200/240 DC: 12, 24, 48, 100 AC: 24, 100/120, 200/240 20 pcs./tray DC: 6, 12, 24, 48, 100 Name Model DIN Track PFP-100N2 PFP-M Spacer PFP-S Model 1 pole G7L-1A-BUBJ 2 poles G7L-2A-BUBJ Rated coil voltage Minimum packing unit AC: 24, 100/120, 200/240 DC: 6, 12, 24, 48 AC: 24, 100/120, 200/240 20 pcs./tray DC: 6, 12, 24, 48, 100 Note 1. Please add the coil rated voltage (V) to the model number when ordering. Example: G7L-1A-T AC12 In addition, the delivered product and its package will be marked with voltage specification as "@@ VDC". Note 2. Refer to the precautions on PCB Relays provided in General Information of the Relay Product Data Book, and "w -@-3" for coil characteristics of AC operation. E-bracket/Adaptor/Socket/Cover Minimum packing unit PFP-50N End plate Number of poles 20 pcs./tray PFP-100N Adaptor Surface Connection Socket Model 2 poles DIN Track Mounting Accessories Applicable products Number of poles 20 pcs./tray PCB Mounting Number of poles DC: 12, 24, 48, 100 Screw Terminal Minimum packing unit Screw Terminal 1 pole AC: 24, 100/120, 200/240 E-bracket/Adapter Mounting (with test button) G 2 poles G7L-2A-B DC: 12, 24, 48, 100 7 L Upper Bracket Mounting Model G7L-2A-TJ 2 poles DC: 6, 12, 24, 48, 100 AC: 12, 24, 100/120, 200/240 Number of poles 2 poles 20 pcs./tray Screw Terminal Model G7L-1A-TJ Minimum packing unit Quick-connect Terminal Minimum packing unit E-bracket/Adapter Mounting Number of poles 1 pole Rated coil voltage Upper Bracket Mounting (with test button) Quick-connect Terminal Model Model 20 pcs./tray Upper Bracket Mounting Number of poles Number of poles 10 pcs. Note. Order the models above in increments of the minimum quantity packaged. Applicable Relay models G7L-1A-T G7L-1A-TJ G7L-1A-B G7L-1A-BJ G7L-2A-T G7L-2A-TJ G7L-2A-B G7L-2A-BJ Name Model Minimum packing unit E-bracket R99-07 10 pcs. Adapter P7LF-D 1 pcs. G7L-1A-T G7L-1A-TJ G7L-2A-T G7L-2A-TJ Front-connecting Socket P7LF-06 1 pcs. G7L-1A-B G7L-1A-BJ G7L-1A-BUB G7L-1A-BUBJ G7L-2A-B G7L-2A-BJ G7L-2A-BUB G7L-2A-BUBJ Cover P7LF-C 1 pcs. Note. Order the models above in increments of the minimum quantity packaged. 2 G7L Power Relay ■Ratings ■Characteristics Coil Max. Must operate Must release permissible Power voltage voltage voltage consumption (VA-W) On the basis of rated voltage Item Rated current (mA) Rated voltage 12 VAC 24 VAC 50 VAC 100 to 120 VAC 200 to 240 VAC 6 VDC 12 VDC 24 VDC 48 VDC 100 VDC Coil inductance (H) Coil resistance (Ω) 142 71 34 17.0 to 20.4 8.5 to 10.2 317 158 79 40 19 Armature ON 18.9 75 303 1220 5260 Armature OFF 0.09 0.37 1.42 6.1 21.3 0.21 0.88 3.54 15.3 60.0 75% max. 15% min. 110% 75 V 150 V 18 V 36 V 132 V 264 V 75% max. 15% min. Approx. 1.7 to 2.5 110% Approx. 1.9 Contact resistance *1 Operate time *2 Release time *3 Max. Mechanical operating frequency Rated load 50 mΩ max. 30 ms max. 30 ms max. Insulation resistance *3 Between coil and contacts Between contacts Dielectric of same polarity strength Between contacts of different polarity (DPST-NO model) 100 MΩ min 4,000 VAC min., 50/60 Hz for 1 min 1,800 operations/hr 1,800 operations/hr 10,000 V between coil and contact *4 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 1,000 m/s2 100 m/s2 1,000,000 operations min. (at 1,800 operations/hr) 100,000 operations min. (at 1,800 operations/hr under rated load) Impulse withstand voltage Note 1. The rated current and coil resistance are measured at a coil temperature of 23•C with tolerances of +15%/-20% for AC rated current and ±15% for DC coil resistance. 2. The inductances shown above are reference values. 3. Performance characteristic data are measured at a coil temperature of 23•C. 4. The maximum allowable coil voltage refers to the maximum value in a varying range of operating power voltage, measured at ambient temperature 23°C. 5. The "to" (for example "100 to 120") represents the range of rated voltages. Destruction Vibration resistance Malfunction Shock resistance Contacts Destruction Malfunction Mechanical Contact Form G7L-1A-T@ G7L-1A-B@ load Item Contact type Contact material Rated load Rated carry current Max. switching voltage Max. switching current Resistive load G7L-2A-T@ G7L-2A-B@ Inductive load (cosφ = 0.4) Inductive load (cosφ = 0.4) Resistive load G7L-1A-P G7L-2A-P Resistive load Double break Ag alloy 25 A at 220 VAC 25 A 30 A at 220 VAC 25 A at 220 VAC 30 A Endurance Electrical *5 Inductive load (cosφ = 0.4) 20 A at 220 VAC 20 A Failure rate (P level) (reference value *6) 100 mA at 5 VDC Weight Approx. 90 g: Quick-connect terminal models Approx. 100 g: PCB terminal models Approx. 120 g: Screw terminal models 250 VAC 30 A 25 A 2,000 VAC, 50/60 Hz for 1 min G 7 L Note. The values given above are initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method. *2. Measurement conditions: Rated operating voltage applied, not including contact bounce. Ambient temperature: 23°C *3. Measurement conditions: The insulation resistance was measured with a 500-VDC megohmmeter at the same locations as the dielectric strength was measured. *4. JEC-212 (1981) Standard Impulse Wave Type (1.2×50μs). *5. Ambient temperature: 23°C *6. This value was measured at a switching frequency of 60 operations/min. 20 A Note. When using B-series (screw) products, since the screw diameter of the contact terminal is M4, be careful that the contact current should be 20 A or less according to JET standard (electrical appliance and material control law of Japan). Ambient operating temperature Ambient operating humidity -25•C to 60•C (with no icing or condensation) 5% to 85% ■Engineering Data AC resistive load 50 30 20 AC inductive load (cosφ = 0.4) 100 AC resistive load AC inductive load (cosφ = 0.4) 50 30 20 Ambient Temperature vs. Operate and Release Voltage G7L-1A VAC (60 Hz) 50 AC resistive load AC inductive load (cosφ = 0.4) 30 20 10 10 10 7 7 7 5 5 5 Operate and Release voltages (%) 100 G7L-1A-P G7L-2A-P Maximum Switching Power Switching current (A) G7L-2A-T (TJ) (TUB) (TUBJ) G7L-2A-B (BJ) (BUB) (BUBJ) Maximum Switching Power Switching current (A) Switching current (A) G7L-1A-T (TJ) (TUB) (TUBJ) G7L-1A-B (BJ) (BUB) (BUBJ) Maximum Switching Power 100 Operate voltage Release voltage 80 60 40 3 3 3 20 1 50 70 100 30 300 500 1,000 1 10 50 70 100 30 Switching voltage (V) Endurance Endurance (x 104 operations) Endurance (x 104 operations) Endurance 500 300 100 300 500 1,000 220 VAC resistive load 70 50 30 10 300 100 220 VAC resistive load 70 50 5 10 15 20 25 30 Switching current (A) 0 -40 300 500 5 10 15 20 25 30 Switching current (A) 0 20 300 100 70 50 220 VAC resistive load 220 VAC inductive load (cosφ = 0.4) 0 5 40 60 80 Ambient temperature (°C) G7L-1A VDC 500 7 5 0 -20 Switching voltage (V) 10 7 5 0 50 70 100 30 220 VAC inductive load (cosφ = 0.4) 10 7 5 30 Endurance 500 30 220 VAC inductive load (cosφ = 0.4) 10 Ambient temperature (°C) Endurance (x 104 operations) 10 Operate and Release voltages (%) 1 10 100 Operate voltage Release voltage 80 60 40 20 15 20 25 30 Switching current (A) 0 -40 -20 0 20 40 60 80 Ambient temperature (°C) 3 G7L Power Relay 80 N=5 Shock Malfunction G7L-2A-T (TUB) 100 to 120 VAC G7L-1A VDC Coil Temperature Rise (°C) Coil Temperature Rise (°C) Ambient Temperature vs. Coil Temperature Rise G7L-1A 120 VAC (50 Hz) 30 A 15 A 0A 60 40 80 N=5 Y 30 A 15 A 0A 400 50 60 0 300 X 40 0 30 0 200 20 0 10 40 0 10 20 40 Test method: The value at which malfunction occurred was measured after applying shock to the test piece 3 times Z' each in 6 directions 0 50 along 3 axes. Standard: 100m/s2 20 100 100 200 40 20 30 0 0 10 0 0 30 0 0 100 0 0 20 N=5 500 X 300 200 0 50 Z 400 300 500 X' Y X' Z Z' 400 0 -40 -20 0 20 40 60 0 -40 80 -20 0 20 Ambient temperature (°C) 40 60 80 500 Ambient temperature (°C) Momentary Voltage Drop Test G7L-2A-T (TUB) 100 to 120 VAC Test Circuit Wave resulted from test Y' Shock direction Y' Number of Relays Voltage distribution of wave e which chattering does not occur. ON Without chattering Ch1 (contact) Unit: (m/s2) OFF 8 n=10 6 4 Rated Ch2 voltage (coil) Ch1 G 7 L e 2 Ch2 0 20 40 60 80 100 On the basis of rated voltage (%) 20 35 N=5 30 Operate time Release time 15 25 10 20 5 15 0 Top A Bottom (Standard) A' B B' (Note) C 0 C' Release voltage N=5 70 Operate voltage 60 50 Top A A' B B' C (Note) 0 C' Top A A' Bottom(Standard) Mounting direction 50 N=5 40 30 Release voltage 20 10 40 Bottom(Standard) Mounting direction 80 On the basis of rated voltage (%) N=5 On the basis of rated voltage (%) 25 Time (ms) Time (ms) Characteristic variation resulted from different mounting directions G7L-2A-T (TUB) 100 to 120 VAC Operate time Release time Operate voltage B B' (Note) C 0 C' Top A Bottom(Standard) Mounting direction A' B B' C (Note) C' Mounting direction (Note.)The mounting direction A’ deteriorates switching performance. 60 Operate voltage 50 40 30 N=5 80 60 40 Release voltage 20 70 Operate voltage N=5 60 50 40 30 Contact resistance Contact resistance (mΩ) 100 N=5 On the basis of rated voltage (%) 70 Operate and Release voltages N=5 Contact resistance Contact resistance (mΩ) On the basis of rated voltage (%) Actual Load Endurance Test G7L-2A 100 to 200 VAC Operate and Release voltages N=5 50 N=5 40 30 20 Release voltage 20 20 10 10 10 0 0.5 0.7 1 3 5 7 10 30 50 Switching operations (×104 operations) 0 0.5 0.7 1 3 5 7 10 30 50 0 0.05 0.07 0.1 Switching operations (×104 operations) Load conditions • 1 φ 220 VAC 0.3 0.5 1 3 5 Switching operations (×104 operations) 0 0.05 0.07 0.1 0.3 0.5 1 3 Load conditions • 1 φ 220 VAC 70 A cosφ = 0.4 54 A cosφ = 0.79 (Compressor Lock Test) 20 A cosφ = 0.4 0.2s 1s 4 1s • Applied coil voltage: 100% of rated voltage 0.5s 10s 5 Switching operations (×104 operations) • Applied coil voltage: 100% of rated voltage G7L Power Relay Operate voltage 60 50 40 50 N=5 40 30 Release voltage 30 20 20 70 N=5 Operate voltage 60 Contact resistance Contact resistance (mΩ) N=5 On the basis of rated voltage (%) 70 Operate and Release voltages N=5 Contact resistance Contact resistance (mΩ) On the basis of rated voltage (%) G7L-2A 100 to 200 VAC Operate and Release voltages N=5 50 40 50 N=5 40 30 Release voltage 30 20 20 10 10 10 10 0 0.5 0.7 1 3 5 10 30 0 0.5 0.7 1 50 Switching operations (×102 operations) 3 5 10 30 0 0.5 0.7 1 50 3 Switching operations (×102 operations) 5 10 30 0 0.5 0.7 1 50 Switching operations (×102 operations) Load conditions • 1 φ 220 VAC 3 5 10 30 50 Switching operations (×102 operations) Load conditions • 1 φ 220 VAC 70 A cosφ = 0.4 20 A cosφ = 0.4 25 A cosφ = 1 2s • Applied coil voltage: 75% of rated voltage 8s • Applied coil voltage: 75% of rated voltage 0.2s 2s 8s ■Dimensions ● E-bracket Mounting Quick-connect Terminals Note. E-brackets are sold separately. G7L-1A-T 52.5 max. 6.35 50.5 max. G 7 L Terminal Arrangement/ Internal Connections (Top View) 33.5 max. 0.8 11 0 53 max. 1 4 6 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram G7L-2A-T 6.35 52.5 max. 50.5 max. 33.5 max. 0.8 11 0 2 53 max. 1 4 6 8 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram G7L-1A-TJ (with Test Button) 6.35 52.5 max. 50.5 max. 33.5 max. Mounting Holes Two, 4.5-dia. hole or M4 tapped holes 2 0.8 Test button 11 40±0.1 0 1 4 53 max. 6 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram G7L-2A-TJ (with Test Button) 6.35 52.5 max. 50.5 max. 33.5 max. 2 0.8 11 Test button 53 max. 0 2 1 4 6 8 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram 5 G7L Power Relay ● Adapter Mounting Quick-connect Terminals Note 1. The DIN Track Mounting Adapter and DIN tracks are sold separately. 2. The DIN Track Mounting Adapter can be track-mounted or screw-mounted. G7L-1A-T Terminal Arrangement/ Internal Connections (Top View) P7LF-D PFP-@N G7L 0 1 51.5 max. 4 55.5 max. 63 max. 5 66.5 max. G7L-2A-T 6 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram P7LF-D PFP-@N G7L 0 1 51.5 max. 2 4 6 8 Mounting Holes 63 max. 55.5 max. 5 66.5 max. G G7L-1A-TJ 7 (with Test Button) L (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram 40±0.1 P7LF-D PFP-@N Two, M4 or 4.5-dia. holes G7L 0 1 51.5 max. 4 2 Test button 63 max. 55.5 max. 5 66.5 max. G7L-2A-TJ (with Test Button) 6 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram P7LF-D PFP-@N G7L 0 1 51.5 max. 2 2 55.5 max. Test button 63 max. 5 66.5 max. ● Front-connecting Socket Mounting Quick-connect Terminals 6 8 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram Note 1. The Front-connecting Socket and DIN tracks are sold separately. 2. The Front-connecting Socket can be track-mounted or screw-mounted. G7L-1A-T PFP-@N 4 2-M3.5 × 6 (coil side) Terminal Arrangement/ Internal Connections (Top View) P7LF-06 G7L 0 1 51.5 max. 4 55.5 max. 61.5 max. 65 max. 4-M4 × 8 (contact side) G7L-2A-T PFP-@N 2-M3.5 × 6 (coil side) 5 6 Mounting Holes (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram 40±0.1 P7LF-06 G7L 0 1 51.5 max. 2 55.5 max. 4-M4 × 8 (contact side) 6 61.5 max. 65 max. Two, M4 or 4.5-dia. holes 5 4 6 8 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram G7L Power Relay G7L-1A-TJ (with Test Button) 2-M3.5 × 6 (coil side) PFP-@N Terminal Arrangement/ Internal Connections (Top View) P7LF-06 G7L 0 1 51.5 max. 4 2 55.5 max. Test button 61.5 max. G7L-2A-TJ (with Test Button) PFP-@N 2-M3.5 × 6 (coil side) 5 65 max. 4-M4 × 8 (contact side) 6 Mounting Holes (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram Two, M4 or 4.5-dia. holes 40±0.1 P7LF-06 G7L 0 1 51.5 max. 2 2 4-M4 × 8 (contact side) 6 8 Test button 61.5 max. 55.5 max. 4 5 65 max. (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram ● Upper Bracket Mounting Quick-connect Terminals G7L-1A-TUB G 7 L 68.5 max. Terminal Arrangement/ Internal Connections (Top View) 60 6.35 50.5 max. 33.5 max. 0.8 11 0 1 47 max. 4 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram 4.5 G7L-2A-TUB 6 68.5 max. 60 6.35 50.5 max. 33.5 max. 0.8 11 0 47 max. 2 4 6 8 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram 2.5 4.5 G7L-1A-TUBJ (with Test Button) 1 Mounting Holes Two, 4.5-dia. hole or M4 tapped holes 68.5 max. 60 6.35 50.5 max. 33.5 max. 60±0.2 2 0.8 11 Test button 0 47 max. 4 6 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram 2.5 4.5 G7L-2A-TUBJ (with Test Button) 1 68.5 max. 60 6.35 50.5 max. 33.5 max. 2 0.8 Test button 11 47 max. 2.5 4.5 0 2 1 4 6 8 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram 7 G7L Power Relay ● E-bracket Mounting Screw Terminals Note. E-brackets are sold separately. G7L-1A-B 2-M3.5 × 6 (coil side) 52.5 max. 50.5 max. 34.5 max. Terminal Arrangement/ Internal Connections (Top View) 2-M4 × 8 (contact side) 0 1 55 max. 4 6 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram G7L-2A-B 52.5 max. 2-M3.5 × 6 (coil side) 50.5 max. 34.5 max. 4-M4 × 8 (contact side) 0 1 55 max. 2 4 6 Mounting Holes 8 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram G7L-1A-BJ (with Test Button) G 7 L 2-M3.5 × 6 (coil side) 52.5 max. 50.5 max. 34.5 max. 2-M4 × 8 2 (contact side) Two, 4.5-dia. hole or M4 tapped holes 40±0.1 Test button 0 1 55 max. 4 6 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram G7L-2A-BJ (with Test Button) 2-M3.5 × 6 (coil side) 52.5 max. 50.5 max. 34.5 max. 4-M4 × 8 2 (contact side) Test button 0 1 55 max. 2 4 6 8 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram ● Adapter Mounting Screw Terminals Note 1. The DIN Track Mounting Adapter and DIN tracks are sold separately. 2. The DIN Track Mounting Adapter can be track-mounted or screw-mounted. G7L-1A-B PFP-@N Terminal Arrangement/ Internal Connections (Top View) P7LF-D 2-M3.5 × 6 (coil side) G7L 0 1 51.5 max. 4 6 Mounting Holes 55.5 max. 2-M4 × 8 (contact side) G7L-2A-B PFP-@N 2-M3.5 × 6 (coil side) 65.5 max. 5 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram 69 max. 40±0.1 P7LF-D G7L 0 1 51.5 max. 2 55.5 max. 4-M4 × 8 (contact side) 8 65.5 max. 69 max. Two, M4 or 4.5-dia. holes 5 4 6 8 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram G7L G7L-1A-BJ (with Test Button) Power Relay PFP-@N Terminal Arrangement/ Internal Connections (Top View) P7LF-D 2-M3.5 × 6 (coil side) G7L 0 1 51.5 max. 4 2 55.5 max. 65.5 max. 2-M4 × 8 (contact side) G7L-2A-BJ (with Test Button) Test button 5 69 max. 6 Mounting Holes (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram Two, M4 or 4.5-dia. holes 40±0.1 PFP-@N 2-M3.5 × 6 (coil side) P7LF-D G7L 0 1 51.5 max. 2 2 55.5 max. Test button 65.5 max. 4-M4 × 8 (contact side) 5 69 max. 4 6 8 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram ● Upper Bracket Mounting Screw Terminals G7L-1A-BUB G 7 L 68.5 max. 2-M3.5 × 6 (coil side) Terminal Arrangement/ Internal Connections (Top View) 60 50.5 max. 2-M4 × 8 (contact side) 34.5 max. 0 49 max. 1 4 2.5 4.5 G7L-2A-BUB 6 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram 68.5 max. 2-M3.5 × 6 (coil side) 60 50.5 max. 4-M4 × 8 (contact side) 34.5 max. 0 49 max. 1 Mounting Holes 2 2.5 6 8 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram 4.5 G7L-1A-BUBJ (with Test Button) 4 Two, 4.5-dia. hole or M4 tapped holes 68.5 max. 2-M3.5 × 6 (coil side) 60 50.5 max. 34.5 max. 2 60±0.2 2-M4 × 8 (contact side) Test button 0 49 max. 1 4 2.5 4.5 G7L-2A-BUBJ (with Test Button) 6 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram 68.5 max. 2-M3.5 × 6 (coil side) 60 50.5 max. 34.5 max. 2 4-M4 × 8 (contact side) Test button 0 1 49 max. 2 2.5 4.5 4 6 8 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram 9 G7L Power Relay ● PCB Mounting PCB Terminals G7L-1A-P 2.8 PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm Terminal Arrangement/ Internal Connections (Top View) 35.5 max. 52.5 max. 0.8 6 36.8 0 1 3.2 47 max. 41 max. (8.4) 4 6 1.2 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram G7L-2A-P 2.8 52.5 max. 0.8 6 17.7 (8.9) 4-1.2 × 3.2 square hole PCB Mounting Holes (Bottom View) Tolerance: ±0.1 mm Terminal Arrangement/ Internal Connections (Top View) 35.5 max. 14.4 36.8 0 1 47 max. 41 max. (8.4) 2 4 6 8 (No coil polarity) Note. Refer to page 12 for the coil internal connection diagram G 7 L ● E-bracket R99-07 (E KANAGU) FOR G7L 3.2 1.2 14.4 17.7 (8.9) 6-1.2 × 3.2 square hole 40 Two, 4.5-dia. hole 26 24 Mounting Holes Two, M4 or 4.5-dia. holes 17.8 40 10 46 3 24 19.7 7 5 36 5 4.4 50 ● Adapter P7LF-D Mounting Holes 51.5 max. Two, M4 or 4.5-dia. holes 40±0.1 40±0.1 14.5 ● Front-connecting Socket 2-M3.5 × 6 (coil side) P7LF-06 5 35.2 max. 55.5 max. 8±0.05 Mounting Holes 51.5 max. Two, M4 or 4.5-dia. holes 40±0.1 4-M4 × 8 (contact side) 9.2±0.05 25 5 46 max. 40±0.1 55.5 max. ● Cover P7LF-C 34.5 max. 50.5 max. 1 6 max. 10 Put the P7LF-C cover onto the terminals in order to protect the user from electric shock. G7L Power Relay Approved Standards x A variety of Safety Standard approved products for standard models. EN/IEC, TÜV Approval UL approval (File No. E41643) Model G7L-1A-T@ G7L-1A-B@ G7L-1A-P G7L-2A-T@ G7L-2A-B@ G7L-2A-P Coil ratings 12 to 240 VAC 6 to 220 VDC CSA approval Model G7L-1A-P Number of test operations 100,000 6,000 1,000 100,000 30,000 Coil ratings 12 to 240 VAC 6 to 220 VDC 12 to 240 VAC 6 to 220 VDC Contact ratings SPST-NO 2.4 kW, 120 VAC (T) 40°C 1.5 HP, 120 VAC (T) 40°C 3 HP 277 VAC 40°C 20.5 FLA/105 LRA, 120 VAC 85°C TV-10, 120 VAC 40°C 30 A, 277 VAC (RES) 40°C 2.4 kW, 120 VAC (T) 40°C 1.5 HP, 120 VAC 40°C 3 HP 277 VAC 40°C 20.5 FLA/105 LRA, 120 VAC 85°C TV-10, 120 VAC 40°C Coil ratings G7L-1A-B@ G7L-2A-B@ G7L-1A-T@ Number of test operations 6,000 1,000 100,000 25,000 100,000 6,000 G7L-2A-T@ G7L-1A-P 1,000 100,000 25,000 ●Reference UL Approved Type .................................................... UL508 Industrial Control Devices UL1950 Information processing equipment (Including office equipment) CSA Approved Type................................................... CSA C22.2 No.1, 14 Industrial Control Devices CSA C22.2 No.950 Information processing equipment (Including office equipment) TÜV EN/IEC Standard Approved Type ...................... EN61810-1 Relay EN60950 Information processing equipment (Including office equipment) IEC950 Information processing equipment (Including office equipment) (File No. R50059083) Contact ratings Model 25,000 (File No. LR31928) G7L-1A-T@ G7L-1A-B@ G7L-2A-T@ G7L-2A-B@ G7L-2A-P Contact ratings SPST-NO 30 A, 277 VAC (RES) 40°C 1.5 kW, 120 VAC (T) 40°C 1.5 HP, 120 VAC 40°C 3 HP 277 VAC 40°C 20 FLA/120 LRA, 120 VAC 40°C 17 FLA/102 LRA, 277 VAC 40°C TV-10, 120 VAC 40°C G7L-2A-P 6, 12, 24, 48, 100, 110, 200, 220 VDC 12, 24, 50, 100 to 120, 200 to 240 VAC SPST-NO 30 A, 250 VAC ~ (cosφ = 1) 60°C 25 A, 250 VAC ~ (cosφ = 0.4) 60°C 30 A, 120 VAC ~ (cosφ = 0.4) 60°C DPST-NO 25 A, 277 VAC ~ (cosφ = 1) 60°C 25 A, 277 VAC ~ (cosφ = 0.4) 60°C SPST-NO 25 A, 240 VAC ~ (cosφ = 1) 60°C 25 A, 240 VAC ~ (cosφ = 0.4) 60°C 25 A, 277 VAC ~ (cosφ = 1) 60°C 25 A, 277 VAC ~ (cosφ = 0.4) 60°C DPST-NO 25 A, 240 VAC ~ (cosφ = 1) 60°C 25 A, 240 VAC ~ (cosφ = 0.4) 60°C 25 A, 277 VAC ~ (cosφ = 1) 60°C 25 A, 277 VAC ~ (cosφ = 0.4) 60°C SPST-NO 20 A, 240 VAC ~ (cosφ = 1) 60°C 20 A, 240 VAC ~ (cosφ = 0.4) 60°C 25 A, 277 VAC ~ (cosφ = 1) 60°C 25 A, 277 VAC ~ (cosφ = 0.4) 60°C DPST-NO 20 A, 240 VAC ~ (cosφ = 1) 60°C 20 A, 240 VAC ~ (cosφ = 0.4) 60°C 25 A, 277 VAC ~ (cosφ = 1) 60°C 25 A, 277 VAC ~ (cosφ = 0.4) 60°C Approved switching operations 50,000 50,000 50,000 50,000 50,000 50,000 11 G 7 L G7L Power Relay ■Precautions ● Please refer to “PCB Relays Common Precautions” for general precautions. Correct Use ● Installation • Although there are not specific limits on the installation site, it should be as dry and dust-free as possible. • Using in an atmosphere of high temperature, high humidity and corrosive gas may deteriorate its performance characteristic caused by condensation or corrosive products, resulting in failure or burn damage of the Relay. • PCB Terminal-equipped Relays weigh approximately 100 g. Be sure that the PCB is strong enough to support them. We recommend dual-side through-hole PCBs to reduce solder cracking from heat stress. • Relays with test buttons must be mounted facing down. Be careful not to touch the test button G accidentally. Doing so may turn ON 7 the contact. L • Be sure to use the test button for test purposes only (with test-button models). The test button is used for Relay circuit tests, such as circuit continuity tests. Do not attempt to switch the load with the test button. ● Micro Loads • The G7L is used for switching power loads, such as motor, transformer, solenoid, lamp, and heater loads. Do not use the G7L for switching micro loads, such as signals. ● Soldering PCB Terminals • Do not perform automatic soldering but solder manually. • Do not wash down the entire Relay because it does not have an airtight construction. ● Connecting • Refer to the following table when connecting a wire with a crimpstyle terminal to the G7L. Screw terminals Front-connecting Socket 8 8 5.8 5 Coil 6.5 5.3 M3.5 M3.5 M4 M4 5.5 5.5 6.5 Contact 9.2 7 9.2 • Allow suitable slack on leads when wiring, and do not apply excessive force to the terminals. • Tightening torque Coil: 0.78 to 1.18 N . m Contact: 0.98 to 1.37 N . m Type Receptacle terminals* #250 terminals (width: 6.35 mm) AMP 170333-1 (170327-1) AMP 170334-1 (170328-1) AMP 170335-1 (170329-1) Positive housing AMP 172076-1 natural color AMP 172076-4 yellow AMP 172076-5 green AMP 172076-6 blue * The numbers shown in parentheses are for air-feeding. Note 1. The current should be 25 A when using receptacle terminals. Note 2. Use receptacle terminals or positive housing for cable wiring. ● Reference Data • The ratio of rated voltage between 100 to 120 VAC are values measured on the basis of 100 VAC. ● Operating Coil (Coil internal connections diagram) • AC Coil 0 1 • DC Coil 0 1 • If a transistor drives the G7L check the leakage current, and connect a bleeder resistor if necessary. • The AC coil is provided with a built-in full-wave rectifier. If a triac, such as an SSR, drives the G7L, the G7L may not release. Be sure to perform a trial operation with the G7L and the triac before applying them to actual use. 12 When connecting with screws, if the screws are not sufficiently tightened, the lead wire can become detached and may lead to abnormal heating or fire caused by faulty contact. • Mounting Torque 0.98N . m Tighten with two M4 screws when mounting. (Top bracket type) • Do not apply excessive force when mounting or dismounting the Faston receptacle.Insert and remove terminals carefully one at a time. Do not insert terminals at an angle, or insert/remove multiple terminals at the same time. • Do not connect to the terminals by soldering ● DIN Track Mounting Adapter and Front-connecting Socket (DIN Track Mounting) • The DIN Track Mounting Adapter and Front-connecting Socket can be mounted on the G7L with just one hand and dismounted with ease by using a screwdriver. • To support the G7L mounted on a DIN Track Mounting Adapter or Front-connecting Socket, use the PFP-M End Plate. Put the End Plate onto the DIN Track Mounting Adapter or Front-connecting Socket so that the surface mark of the End Plate faces upwards. Then tighten the screw of the End Plate securely with a screwdriver. (Screw Mounting) • Screw-mount the DIN Track Mounting Adapter or Front-connecting Socket securely after opening screw mounting holes on them. • When cutting or opening holes on the panel after the Front-connecting Socket is mounted, take proper measures so that the cutting chips will not fall onto the Relay terminals. When cutting or opening holes on the upper part of the panel, mask the Front-connecting Socket properly with a cover. G7L Power Relay G 7 L • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. J055-E1-06 0513(0207)(O) 13