Indoor Air Switch Disconnector, NAL Indoor Air Switch Disconnector, NALF Catalogue 1YMR602160-en ABB Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF Contents NAL/NALF 12-17,5-24-36-40,5 1. General ....................................................................................... 3 2. Short-circuit making capacity .................................................... 3 3. Environmental withstand ability ................................................. 3 4. Functional description ............................................................... 3 5. Standard features ...................................................................... 4 6. Mechanisms ............................................................................... 4 7. Earthing switch ........................................................................... 5 8. Motor operation .......................................................................... 5 9. Ordering codes .......................................................................... 6 10.Options ....................................................................................... 7 11.Example of installed switches ................................................... 8 12.Technical Specifications ............................................................ 9 13.Ordering information ................................................ 11,12,13,14 14.Operating equipment and options ..................................... 15,16 15.Dimemsional drawing ................... 17, 18, 19, 20, 21, 22, 23, 24 2 ABB Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF 1. GENERAL Fig. 1 Fig. 2 The switch disconnector system NAL/NALF is based on a modular principle. The basic unit consists of a frame with insulators and current carrying parts. Two different types of operating mechanisms: snap action mechanism type K or stored spring energy mechanism type A, can be mounted on the frame. Fuse bases type F with tripping mechanism can also be fitted. A triple pole earthing switch type EB with a snap action mechanism and making capacity is also available. These different modules can be combined in various ways in order to meet your specific requirements. Accessories such as shunt trip, under-voltage release, auxiliary switches, motor operation and various systems for manual operation can easily be added. ABB’s switch disconnector type NAL and fuse switch disconnector type NALF have primarily been developed for use within the following areas: - as line and transformer switches within distribution networks - as motor switches - as capacitor switches By combining NAL, which disconnects load currents and small fault currents circuit, with a current limiting fuse (F), which breaks large short circuit currents, the result is an ideal combination. This combination (NALF) provides protection towards all types of faults in the network. ABB has been producing switch disconnectors for more than 50 years. The NAL was introduced in 1978 and has been undergoing continuos development to satisfy the users’ demands. More than 500 000 switches have been produced and are sold throughout the world. The switch disconnectors meet IEC Publication 60129, 60265, 60694, 62271, GOST 1516.3-96, GOST 17717-79, ANSI Standard No. C37.20.4 and CSA Standard No. C22.2, No. 193 concerning switches for general use and for safe co-operation between switch disconnector and fuse. Fig. 1 Fig. 2 NAL in network NAL in cell 2. SHORT-CIRCUIT MAKING CAPACITY With carefully designed contact geometry and high contact velocities the NAL switches are able to close safely on short circuits of up to 1550 MVA at 36 kV. 3. ENVIRONMENTAL WITHSTAND ABILITY The switch disconnectors comply with IEC requirements for equipment for indoor use. The mechanisms are corrosion protected by zink plating and a supplementary chromate treatment, and the frames are painted with corroision resistant powder coating. In order to ensure a safe operation even after years in service under all climatic conditions, the mechanisms are generally fitted with plastic bearings. NAL switch disconnector is manufactured according to our strict quality and environment procedures. Our ISO 9001 and ISO 14001 certifications assures the quality and environmental excellence. NAL switch disconnector is 98,64% recyclable. 4. FUNCTIONAL DESCRIPTION To ensure correct operation for all relevant currents, the switch disconnector system NAL/NALF is equipped with a dual arc extinguishing system. When interrupting the current, the arc will be exposed to: a) A current independent air blast which automatically starts at the correct time during the interrupting process. This is achieved by designing the insulators on the opening side as cylinders with pistons. The pistons are connected to the mechanism in the same way as the moving contacts. The air blast therefore starts simultaneously with the contact movement (autopneumatic air blast). b) A current dependent gas blast which occurs when the walls of the arcing nozzles are exposed to the hot arc. During this process, large volumes of gas are released and the arc is effectively cooled. The concentration of the developed gas increases with increasing current. The so called Hart gas effect is therefore most important at high currents. ABB 3 Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF A well balanced utilization of these two effects has resulted in an arc extinguishing system with a high reliability for all relevant currents. Because of the autopneumatic air blast it will only be necessary to utilize the Hart gas effect for the high currents. This gives an arcing system which can withstand a large number of operations without excessive wear. Consequently the NAL switches comply with highest electrical perfomance classes of IEC 60265-1 (for selected nominal voltages only). 5. STANDARD FEATURES NAL The standard feature consists of chassis, insulators and current carrying parts with the following pole distance: 12 kV – pole distance 150 mm, 170 mm and 210 mm 17,5 kV – pole distance 170 mm and 210 mm 24 kV – pole distance 170 mm*, 235 mm and 275 mm 36/40,5 kV – pole distance 360 mm * - with insulating barriers Fig. 3 Rated currents are 400, 630 and 1250 A up to 24 kV and 630/800 A for 36/40,5 kV NALF Fig. 4 Is delivered with the same pole distances as the standard feature. Fuse base type F is delivered for installation on both the opening side and the pivot side, with or without automatic tripping. Fuse base with 6 insulators can also be delivered separately with signal at fuse blown, or for installation on the pivot side of the switch. 6. MECHANISMS A-MECHANISM – with two springs. The opening spring is always charged before the switch can be closed by means of the closing spring. This means that a closed switch always has the opening spring charged, and the switch can be tripped immediately by hand, electrically or by a fuse-link striker system. K-MECHANISM – with one spring Fig. 5 Closing or opening the switch is performed by charging the spring past the dead centre. KS-MECHANISM is a standard K-mechanism equipped with a latching mechanism type S, which results in the latch being stopped past the dead centre. Thereby, the mechanism is ready for opening/closing by an operating coil or pneumatically by a pump. NB!: Fig. 6 - The switching operation can not be completed by the operating handle. - The spring must be charged before each operation. The KS combination is suitable for remote operation in case where the spring mechanism can be charged manually. KS-mechanism can not be mechanically interlocked. Fig. 7 A and K mechanisms Can be equipped with motor operation. (KS on request) Fig. 5 A-mechanism Fig. 6 K-mechanism Fig. 7 KS-mechanism 4 ABB Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF 7. EARTHING SWITCH EARTHING SWITCH TYPE E – with snap action spring mechanism Fig. 8 The earthing switch can be mounted on the pivot side of the switch and on the fuse base when the latter is on the pivot side of the switch. EARTHING SWITCH TYPE EB – can be delivered for separate installation. Fig. 9 FUSE BASES TYPE F with or without automatic tripping of the switch by the fuse-link striker system. The fuse base can be mounted on both sides (i.e. opening side or pivot side of the switch). 8. MOTOR OPERATION The motor operation is very flexible when it comes to installation. It can be installed at the switch axle’s right or left side, directly on the switch or on the axle’s extension. Can be delivered for all normed voltages. Fig. 10 If motor operation is desired mounted on the front panel, UEMC40A2 can be used. Can be delivered for all normed voltages. Fig. 11 Fig. 8 Type E Fig. 9 Type EB Fig. 10 Motor operation mounted on switch type UEMC 40 K3/NM Fig. 11 Motor operation mounted in cell front type UEMC 40 A2 ABB 5 Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF 9. ORDERING CODES NAL Switch disconnector, F with integrated fuse base 1) 12 Rated voltage 12 kV 17 Rated voltage 17,5 kV 24 Rated voltage 24 kV 36 Rated voltage 36 kV 40,5 Rated voltage 40,5 kV 43) Rated current 400 A 6 Rated current 630 A 82) Rated current 800 A 123) Rated current 1250 A without mechanism K Snap action mechanism A Stored spring energy mechanism KS Latched snap action mechanism 4) 150 Pole distance 12 kV 170 Pole distance 12 kV, 17,5 kV and 24 kV 210 Pole distance 12 kV and 17,5 kV 235 Pole distance 24 kV 275 Pole distance 24 kV 360 Pole distance 36/40,5 kV R Right hand side operation L Left hand side operation 5) E Quick -make earthing switch 6) Index explanations 1) additional information needed when placing the order: the length of fuse link mounting side - pivot or opening with or withour fuse tripping 2) for 36/40,5 kV only 3) up to 24 kV only 4) closing or opening of switch disconnector must be carried by a coil 5) for left hand operation shaft extension must be used 6) the earthing switch is normally delivered without mechanical interlocking that must be spefified seperatelly. For 36/40,5 kV earthing switch is provided as self standing only type EB. Ordering example A: Switch disconnector for 17,5kV / 1250A with latched snap action mechanism, pole distance 170 mm. The switch disconnector is lefthand operated and equipped with quick-make earthing switch. Ordering example B: Switch disconnector for 24kV / 630A with stored spring energy mechanism type A, equipped with fuse-base on the pivot side, with fuse-tripping device, pole distance 235mm, right-hand operated. 1) Normally, the switch disconnector is delivered with fuse base for pivot side mounting. Fuse base for opening side mounting must be specified in the order. 2) Closing or opening of the switch disconnector must be carried out by a coil by operating coil. Additional charge. 3) For left-hand operation, a shaft extension must be used. Additional charge. 4) The earthing switch is normally delivered without mechanical interlocking. Additional charge for interlocking. 6 ABB Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF 10. OPTIONS AUXILIARY SWITCH for blown fuse (fig. 12). Fig. 12 Fig. 13 SHAFT EXTENSION with joint link, 380/470 mm (fig. 13). + connection kit for assembling SHAFT EXTENSION for left-hand operation of switch (fig. 14). Fig. 14 LEVER for switchchrod operation (fig. 15). Fig. 15 TEST FUSE LINK - adjustable (fig. 16). Fig. 16 OPERATION (b) Fig. 17 (c) (a) Manual operation of HE consists of (fig. 17): - lower part (a) - upper part (b) - shaft - connection rod (c) Lower part for HE can be equipped with blocking coil for all normed voltages (fig. 18). MANUAL OPERATION TYPE HE Please observe! The mechanism shaft does not pass through the switch from the mechanism on the right-hand side to the left side, special extension shaft is needed for operation of the mechanism from the left-hand side. Fig. 18 SHUNT TRIP can be mounted on all A-mechanisms. Shunt trip coil is available for following voltages: 24,48, 110, 220 V DC and 110, 220 V AC. The shunt trip coil shall always be connected in series with an auxiliary switch, disconnecting the shunt trip coil when the switch is open. Fig. 19 MECHANICAL INTERLOCKING BETWEEN SWITCH AND EARTHING SWITCH At earth on fuse base, the interlocking design depends upon the length of the fuse. Therefore, the fuse size must be stated. KS-mechansism can not be interlocked to earthing switch (fig. 20). Fig. 20 AUXILIARY SWITCH can be mounted on all switch disconnectors, max. 8NO and 8NC and on all earthing switches, max. 4NO + 4NC (fig. 21). Fig. 21 ABB 7 Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF 11. EXAMPLE OF MOUNTING OF SWITCH NALF Mechanisms Auxiliary switch HE-operation – upper part Lever for switchrod operation Auxiliarty switch at blown fuse Shaft extension for left-hand operation Shunt trip Mechanical interlocking HE-operation – lower part (mounted in cell front) Earthing switch type E 8 Motoroperation ABB Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF 12. TECHNICAL SPECIFICATIONS TABLE I Switch disconnector type NAL The switch disconnector complies with IEC publications 129, 254 and 694 concerning general purpose switches, IEC publication 420 regarding correct co-operation between switch disconnector and fuse. Rated voltage Un kV Rated current In A Max. rated current I A Short circuit making capacity Ima kA peak Peak withstand current Idyn kA peak Short time current 1 sec. Ith kA eff 2 sec. " " 3 sec. " " Mainly active load breaking capacity 2) (test duty 1 and 2, IEC 265) I A Mainly capacitive breaking capacity (test duty 4, IEC 265) I A Mainly inductive breaking capacity cos ϕ = 0,15 A Rated earth fault breaking capacity, IEC 265 Earth fault breaking capacity, fig. 6 I A Capacitive breaking capacity, fig. 7 I A Max. breaking capacity in co-operation with fuses (IEC 420 1990-11) A In A Max. fuse size 4) Power frequency withstand voltage 50 Hz 1 min. - to earth and between poles kV - across isolating distance kV Impulse withstand voltage 1,2/50 us. - to earth and between poles kV - across isolating distance kV Pole distance P mm Max. operating torque at: - closing K/A mech. Nm - opening K/A mech. Nm Operating angle on the shaft degrees Opening time ms Arc time ms 12 kV 400 630 400 630 67 67 82 82 31,5 31,5 25 25 20 20 1250 1150 67 82 31,5 25 20 17,5 kV 400 630 1250 400 630 1150 50 50 50 82 82 82 31,5 31,5 31,5 25 25 25 400 400 50 62,5 31,5 25 16 24 kV 630 1250 630 1150 50 50 62,5 82 31,5 31,5 25 25 16 16 36 kV 630 800 630 800 50 50 66 66 40,5 630 630 50 66 kV 800 800 50 66 25 25 25 25 400 630 1250 400 630 1250 400 630 1250 630 800 630 800 150 150 150 45 45 45 80 80 80 50 50 50 50 16 16 16 16 16 16 16 16 16 165) 165) 165) 165) 150 90 150 90 150 90 70 40 70 40 70 40 75 75 75 31,5 31,5 31,5 50 50 50 50 900 900 80 80 300 40 300 40 300 40 300 40 1600 1600 125 125 1600 1600 125 125 42 48 45 60 55 70 80 88 95 120 75 85 150, 170 and 210 95 110 170 and 210 125 145 1706), 235 and 275 170 195 190 220 Earthing switch type E 1) for NAL/NALF and type EB Rated voltage Un kV Peak withstand current3) Idyn. kA peak Short time current 1 sec. Ith kA eff 2 sec. " " 3 sec. " " Short circuit making capacity 3) Ima kA peak Test voltage 50 Hz 1 min. kV Power frequency withstand voltage 1,2 / 50 us. kV 115 - 120 Nm K-mech. 120 Nm / A-mech. 3 Nm 130 40 - 60 10 - 20 12 62/82 31,5 25 20 62/67 42 82 Pole distance P mm 175 and 210 Mechanical interlocking can be fitted, but not for KS-mechanism. 2) At In = 630 A, 100 x CO. At In = 1250 A, 20 x CO. 3) When fed from switch disconnector/earthing switch side. 4) Max. fuse size is ref. to time current characteristics for CEF. 5) Power factor =0,1 6) With insulating barriers 17,5 40/82 31,5 360 80 - 100 Nm K-mech 80 - 100 Nm 120 60 35 40/62,5 45 95 24 38/82 31,5 25 16 38/50 55 125 36 66 50 80 170 170 and 210 170, 235 and 275 360 25 1) ABB 9 Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF TABLE II according to CSA -C22.2 Rated Nominal Voltage Rated Maximum Voltage Rated Current Impulse Test Voltage Power Frequency Withstand Voltage Pole Spacing kV kV A kV kV mm/inches 4,16 4,76 600/1200 60 28 150/5,9 210/8,25 Momentary Rating Current Fault-Closing Rating Current Short Time Current kA asym. kA asym. kA sym.-2s 40 40 25 13,8 15 600/1200 95 38 170/6,69 210/8,25 235/9,25 40 40 25 27,6 29,8 600/1200 125 60 235/9,25 275/10,8 34,5 38 600/800 150 70 360/14,1 40 40 25 40 30 25 TABLE III according to ANSI C 37.20.4 Rated Nominal Voltage Rated Maximum Voltage Rated Current Impulse Test Voltage Power Frequency Withstand Voltage Pole Spacing Momentary Rating Current Fault-Closing Rating Current Short Time Current kV kV A kV kV mm/inches kA asym. kA asym. kA sym.-2s 4,73 8,25 200/600/1200 75 26 210/8,25 40 40 25 12-13,8 15 200/600/1200 95 36 170/6,69 40 40 25 12-16,8 17 200/600/1200 110 50 235/9,25 40 40 25 22,9-24,9 27 200/600/1200 125 60 275/10,8 40 40 25 34,5 38 600/800 150 80 360/14,1 40 30 25 Other technical specification see Table I 10 ABB Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF Main switch with snap action mechanism (K-mechanism) NAL 12-4K150R NAL 12-4K170R NAL 12-4K210R NAL 12-6K150R NAL 12-6K170R NAL 12-6K210R NAL 12-12K150R NAL 12-12K170R NAL 12-12K210R NAL 17-4K170R NAL 17-4K210R NAL 17-6K170R NAL 17-6K210R NAL 17-12K170R NAL 17-12K210R NAL 24-4K170R NAL 24-4K235R NAL 24-4K275R NAL 24-6K170R NAL 24-6K235R NAL 24-6K275R NAL 24-12K170R NAL 24-12K235R NAL 24-12K275R NAL 36-6K360R NAL 36-8K360R NAL 40-6K360R NAL 40-8K360R Fig. 22 Fig. 23 13. ORDERING INFORMATION Rated Rated Pole distvoltage current ance mm Ident. no. Weight, kg Main switch without mechanism NAL12-4 NAL 12-4 NAL 12-4 NAL 12-6 NAL 12-6 NAL 12-6 NAl 12-12 NAL 12-12 NAL 12-12 NAL 17-4 NAL 17-4 NAL 17-6 NAL 17-6 NAL 17-12 NAL 17-12 NAL 24-4 NAL 24-4 NAL 24-4 NAL 24-6 NAL 24-6 NAL 24-6 NAL 24-12 NAL 24-12 NAL 24-12 NAL 36-6 NAL 36-8 NAL 40-6 NAL 40-8 ABB 12 12 12 12 12 12 12 12 12 17,5 17,5 17,5 17,5 17,5 17,5 24 24 24 24 24 24 24 24 24 36 36 40,5 40,5 400 400 400 630 630 630 1250 1250 1250 400 400 630 630 1250 1250 400 400 400 630 630 630 1250 1250 1250 630 800 630 800 150 170 210 150 170 210 150 170 210 170 210 170 210 170 210 170 235 275 170 235 275 170 235 275 360 360 360 360 1YMX054010M0001 1YMX065170M0001 1YMX054910M0001 1YMX054011M0001 1YMX065170M0002 1YMX054911M0001 1YMX054012M0001 1YMX065170M0003 1YMX054912M0001 1YMX054013M0001 1YMX065210M0001 1YMX054014M0001 1YMX065210M0002 1YMX054015M0001 1YMX065210M0003 1YMX065171M0001 1YMX054016M0001 1YMX054410M0001 1YMX065171M0002 1YMX054017M0001 1YMX054411M0001 1YMX065171M0003 1YMX054018M0001 1YMX054412M0001 1YMX054363M0001 1YMX054314M0001 1YMX065363M0001 1YMX065314M0001 30 30 30 30 30 30 31 31 31 32 32 32 32 33 33 40 40 40 40 40 40 41 41 41 67 67 68 68 Main switch with latched snap action mechanism (KS-mechanism) Fig. 24 Type 12 12 12 12 12 12 12 12 12 17,5 17,5 17,5 17,5 17,5 17,5 24 24 24 24 24 24 24 24 24 36 36 40,5 40,5 400 400 400 630 630 630 1250 1250 1250 400 400 630 630 1250 1250 400 400 400 630 630 630 1250 1250 1250 630 800 630 800 150 170 210 150 170 210 150 170 210 170 210 170 210 170 210 170 235 275 170 235 275 170 235 275 360 360 360 360 1YMX054150M0001 1YMX064170M0001 1YMX054950M0001 1YMX054141M0001 1YMX064170M0002 1YMX054971M0001 1YMX054152M0001 1YMX064170M0003 1YMX054952M0001 1YMX054153M0001 1YMX064210M0001 1YMX054144M0001 1YMX064210M0002 1YMX054155M0001 1YMX064210M0003 1YMX064171M0001 1YMX054156M0001 1YMX054456M0001 1YMX064171M0002 1YMX054147M0001 1YMX054467M0001 1YMX064171M0003 1YMX054158M0001 1YMX054458M0001 1YMX054310M0001 1YMX054311M0001 1YMX064310M0001 1YMX064311M0001 25 25 25 25 25 25 26 26 26 27 27 27 27 28 28 35 35 35 35 35 35 36 36 36 62 62 63 63 NAL 12-4KS150R NAL 12-4KS170R NAL 12-4KS210R NAL 12-6KS150R NAL 12-6KS170R NAL 12-6KS210R NAL 12-12KS150R NAL 12-12KS170R NAL 12-12KS210R NAL 17-4KS170R NAL 17-4KS210R NAL 17-6KS170R NAL 17-6KS210R NAL 17-12KS170R NAL 17-12KS210R NAL 24-4KS170R NAL 24-4KS235 NAL 24-4KS275R NAL 24-6KS170R NAL 24-6KS235R NAL 24-6KS275R NAL 24-12KS170R NAL 24-12KS235R NAL 24-12KS275R NAL 36-6KS360R NAL 36-8KS360R NAL 40-6KS360R NAL 40-8KS360R 12 12 12 12 12 12 12 12 12 17,5 17,5 17,5 17,5 17,5 17,5 24 24 24 24 24 24 24 24 24 36 36 40,5 40,5 400 400 400 630 630 630 1250 1250 1250 400 400 630 630 1250 1250 400 400 400 630 630 630 1250 1250 1250 630 800 630 800 150 170 210 150 170 210 150 170 210 170 210 170 210 170 210 170 235 275 170 235 275 170 235 275 360 360 360 360 1YMX054025M0001 1YMX066170M0001 1YMX054915M0001 1YMX054026M0001 1YMX066170M0002 1YMX054916M0001 1YMX054027M0001 1YMX066170M0003 1YMX054917M0001 1YMX054028M0001 1YMX066210M0001 1YMX054029M0001 1YMX066210M0002 1YMX054030M0001 1YMX066210M0003 1YMX066171M0001 1YMX054031M0001 1YMX054415M0001 1YMX066171M0002 1YMX054032M0001 1YMX054416M0001 1YMX066171M0003 1YMX054033M0001 1YMX054417M0001 1YMX054316M0001 1YMX054317M0001 1YMX066316M0001 1YMX066317M0001 32 32 32 32 32 32 33 33 33 34 34 34 34 35 35 40 40 40 40 40 40 41 41 41 67 67 68 68 Main switch with stored spring energy mechanism (A-mechanism) NAL 12-4A150R NAL 12-4A170R NAL 12-4A210R NAL 12-6A150R NAL 12-6A170R NAL 12-6A210R NAL 12-12A150R NAL 12-12A170R NAL 12-12A210R NAL 17-4A170R NAL 17-4A210R NAL 17-6A170R NAL 17-6A210R NAL 17-12A170R NAL 17-12A210R NAL 24-4A170R NAL 24-4A235R NAL 24-4A275R NAL 24-6A170R NAL 24-6A235R NAL 24-6A275R NAL 24-12A170R NAL 24-12A235R NAL 24-12A275R NAL 36-6A360R NAL 36-8A360 NAL 40-6A360R NAL 40-8A360R 12 12 12 12 12 12 12 12 12 17,5 17,5 17,5 17,5 17,5 17,5 24 24 24 24 24 24 24 24 24 36 36 40,5 40,5 400 400 400 630 630 630 1250 1250 1250 400 400 630 630 1250 1250 400 400 400 630 630 630 1250 1250 1250 630 800 630 800 150 170 210 150 170 210 150 170 210 170 210 170 210 170 210 170 235 275 170 235 275 170 235 275 360 360 360 360 1YMX054040M0001 1YMX067170M0001 1YMX054920M0001 1YMX054041M0001 1YMX067170M0002 1YMX054921M0001 1YMX054042M0001 1YMX067170M0003 1YMX054922M0001 1YMX054043M0001 1YMX067210M0001 1YMX054044M0001 1YMX067210M0002 1YMX054045M0001 1YMX067210M0003 1YMX067171M0001 1YMX054046M0001 1YMX054420M0001 1YMX067171M0002 1YMX054047M0001 1YMX054421M0001 1YMX067171M0003 1YMX054048M0001 1YMX054422M0001 1YMX054319M0001 1YMX054320M0001 1YMX067319M0001 1YMX067320M0001 32 32 32 32 32 32 33 33 33 34 34 34 34 35 35 42 42 42 42 42 42 43 43 43 68 68 69 69 11 Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF Type Rated Rated Pole distvoltage current ance mm Ident. no. Weight kg Main switch with fuse base and snap action mechanism, without fuse tripping NALF 12-4K150R NALF 12-4K170R NALF 12-4K210R NALF 12-6K150R NALF 12-6K170R NALF 12-6K210R NALF 17-4K170R NALF 17-4K210R NALF 17-6K170R NALF 17-6K210R NALF 24-4K170R NALF 24-4K235R NALF 24-4K275R NALF 24-4K170R NALF 24-6K235R NALF 24-6K275R NALF 36-6K360R NALF 36-8K360R NALF 40-6K360R NALF 40-8K360R Fig. 25 12 12 12 12 12 12 17,5 17,5 17,5 17,5 24 24 24 24 24 24 36 36 40,5 40,5 400 400 400 630 630 630 400 400 630 630 400 400 400 630 630 630 630 800 630 800 150 170 210 150 170 210 170 210 170 210 170 235 275 170 235 275 360 360 360 360 1YMX054070M0001 1YMX068170M0001 1YMX054925M0001 1YMX054071M0001 1YMX068170M0002 1YMX054926M0001 1YMX054072M0001 1YMX068210M0001 1YMX054073M0001 1YMX068210M0002 1YMX068171M0001 1YMX054074M0001 1YMX054425M0001 1YMX068171M0002 1YMX054075M0001 1YMX054426M0001 1YMX054322M0001 1YMX054323M0001 1YMX068322M0001 1YMX068323M0001 39 39 39 39 39 39 42 42 42 42 51 51 51 51 51 51 68 68 69 69 Main switch with fuse base and latched snap action mechanism, with fuse tripping NALF 12-4KS150R NALF 12-4KS170R NALF 12-4KS210R NALF 12-6KS150R NALF 12-6KS170R NALF 12-6KS210R NALF 17-4KS170R NALF 17-4KS210R NALF 17-6KS170R NALF 17-6KS210R NALF 24-4KS170R NALF 24-4KS235R NALF 24-4KS275R NALF 24-6KS170R NALF 24-6KS235R NALF 24-6KS275R NALF 36-6KS360R NALF 36-8KS360R NALF 40-6KS360R NALF 40-8KS360R 12 12 12 12 12 12 17,5 17,5 17,5 17,5 24 24 24 24 24 24 36 36 40,5 40,5 400 400 400 630 630 630 400 400 630 630 400 400 400 630 630 630 630 800 630 800 150 170 210 150 170 210 170 210 170 210 170 235 275 170 235 275 360 360 360 360 1YMX054080M0001 1YMX069170M0001 1YMX054930M0001 1YMX054081M0001 1YMX069170M0001 1YMX054931M0001 1YMX054082M0001 1YMX069210M0001 1YMX054083M0001 1YMX069210M0002 1YMX069171M0001 1YMX054084M0001 1YMX054430M0001 1YMX069171M0002 1YMX054085M0001 1YMX054431M0001 1YMX054325M0001 1YMX054326M0001 1YMX069325M0001 1YMX069326M0001 41 41 41 41 41 41 44 44 44 44 53 53 53 53 53 53 70 70 71 71 Main switch with fuse base and stored spring energy mechanism, with fuse tripping Fig. 26 NALF 12-4A150R NALF 12-4A170R NALF 12-4A210R NALF 12-6A150R NALF 12-6A170R NALF 12-6A210R NALF 17-4A170R NALF 17-4A210R NALF 17-6A170R NALF 17-6A210R NALF 24-4A170R NALF 24-4A235R NALF 24-4A275R NALF 24-6A170 NALF 24-6A235R NALF 24-6A275R NALF 36-6A360R NALF 36-8A360R NALF 40-6A360R NALF 40-8A360R 12 12 12 12 12 12 17,5 17,5 17,5 17,5 24 24 24 24 24 24 36 36 40,5 40,5 400 400 400 630 630 630 400 400 630 630 400 400 400 630 630 630 630 800 630 800 150 170 210 150 170 210 170 210 170 210 170 235 275 170 235 275 360 360 360 360 1YMX054090M0001 1YMX070170M0001 1YMX054935M0001 1YMX054091M0001 1YMX070170M0002 1YMX054936M0001 1YMX054092M0001 1YMX070210M0001 1YMX054093M0001 1YMX070210M0002 1YMX070171M0001 1YMX054094M0001 1YMX054435M0001 1YMX070171M0002 1YMX054095M0001 1YMX054436M0001 1YMX054328M0001 1YMX054329M0001 1YMX070328M0001 1YMX070329M0001 41 41 41 41 41 41 44 44 44 44 53 53 53 53 53 53 70 70 71 71 1YMX084141M0001 1YMX084152M0001 1YMX084971M0001 1YMX089952M0001 1YMX084144M0001 1YMX084155M0001 1YMX084210M0002 1YMX084210M0003 1YMX084147M0001 1YMX084158M0001 1YMX184147M0001 1YMX184158M0001 1YMX084467M0001 1YMX084458M0001 1YMX084310M0001 1YMX084311M0001 25 26 25 26 27 28 27 28 35 36 35 36 35 36 62 62 CSA Main switch without mechanism NAL 4-6 150 NAL 4-12 150 NAL 4-6 210 NAL 4-12 210 NAL 13-6 170 NAL 13-12 170 NAL 13-6 210 NAL 13-12 210 NAL 13-6 235 NAL 13-12 235 NAL 27-6 235 NAL 27-12 235 NAL 27-6 275 NAL 27-12 275 NAL 34-6 360 NAL 34-8 360 12 4,16 4,16 4,16 4,16 13,8 13,8 13,8 13,8 13,8 13,8 27,6 27,6 27,6 27,6 34,5 34,5 600 1200 600 1200 600 1200 600 1200 600 1200 600 1200 600 1200 600 800 150 150 210 210 170 170 210 210 235 235 235 235 275 275 360 360 ABB Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF Type Rated Rated Pole distvoltage current ance mm Ident. no. Weight kg CSA Main switch with snap action mechanism (K-mechanism) NAL 4-6 150KR NAL 4-12 150KR NAL 4-6 210KR NAL 4-12 210KR NAL 13-6 170K17R NAL 13-12 170K17R NAL 13-6 170K24R NAL 13-12 170K24R NAL 13-6 210K17R NAL 13-12 210K17R NAL 13-6 210K24R NAL 13-12 210K24R NAL 13-6 235K17R NAL 13-12 235K17R NAL 13-6 235K24R NAL 13-12 235K24R NAL 27-6 235K24R NAL 27-12 235K24R NAL 27-6 275K24R NAL 27-12 275K24R NAL 34-6 360KR NAL 34-8 360KR 4,16 4,16 4,16 4,16 13,8 13,8 13,8 13,8 13,8 13,8 13,8 13,8 13,8 13,8 13,8 13,8 27,6 27,6 27,6 27,6 34,5 34,5 600 1200 600 1200 600 1200 600 1200 600 1200 600 1200 600 1200 600 1200 600 1200 600 1200 600 800 150 150 210 210 170 170 170 170 210 210 210 210 235 235 235 235 235 235 275 275 360 360 1YMX084011M0001 1YMX084012M0001 1YMX084911M0001 1YMX084912M0001 1YMX084014M0001 1YMX084015M0001 1YMX084014M0002 1YMX084015M0002 1YMX085210M0002 1YMX085210M0003 1YMX085210M0004 1YMX085210M0005 1YMX084017M0001 1YMX084018M0001 1YMX084017M0002 1YMX084018M0002 1YMX184017M0001 1YMX184018M0001 1YMX084411M0001 1YMX084412M0001 1YMX084363M0001 1YMX084314M0001 4,16 4,16 4,16 4,16 13,8 13,8 13,8 13,8 13,8 13,8 27,6 27,6 27,6 27,6 34,5 34,5 600 1200 600 1200 600 1200 600 1200 600 1200 600 1200 600 1200 600 800 150 150 210 210 170 170 210 210 235 235 235 235 275 275 360 360 1YMX084026M0001 1YMX084027M0001 1YMX084916M0001 1YMX084917M0001 1YMX084029M0001 1YMX084030M0001 1YMX086210M0002 1YMX086210M0003 1YMX084032M0001 1YMX084033M0001 1YMX184032M0001 1YMX184033M0001 1YMX084416M0001 1YMX084417M0001 1YMX054316M0001 1YMX054317M0001 30 31 30 31 32 33 32 33 32 33 32 33 40 41 40 41 40 41 40 41 67 67 32 33 32 33 34 35 34 35 40 41 40 41 40 41 67 67 CSA Main switch with stored spring energy mechanism (A-mechanism) NAL 4-6 150AR NAL 4-12 150AR NAL 4-6 210AR NAL 4-12 210AR NAL 13-6 170A17R NAL 13-12 170A17R NAL 13-6 170A24R NAL 13-12 170A24R NAL 13-6 210A17R NAL 13-12 210A17R NAL 13-6 210A24R NAL 13-12 210A24R NAL 13-6 235A17R NAL 13-12 235A17R NAL 13-6 235A24R NAL 13-12 235A24R NAL 27-6 235A24R NAL 27-12 235A24R NAL 27-6 275A24R NAL 27-12 275A24R NAL 34-6 360AR NAL 34-8 360AR ABB 4,16 4,16 4,16 4,16 13,8 13,8 13,8 13,8 13,8 13,8 13,8 13,8 13,8 13,8 13,8 13,8 27,6 27,6 27,6 27,6 34,5 34,5 600 1200 600 1200 600 1200 600 1200 600 1200 600 1200 600 1200 600 1200 600 1200 600 1200 600 800 150 150 210 210 170 170 170 170 210 210 210 210 235 235 235 235 235 235 275 275 360 360 1YMX084041M0001 1YMX084042M0001 1YMX084921M0001 1YMX084922M0001 1YMX084404M0001 1YMX084045M0001 1YMX084404M0002 1YMX084045M0002 1YMX087210M0002 1YMX087210M0003 1YMX087210M0004 1YMX087210M0005 1YMX084047M0001 1YMX084048M0001 1YMX084047M0002 1YMX084048M0002 1YMX184047M0001 1YMX184048M0001 1YMX084421M0001 1YMX084422M0001 1YMX084319M0001 1YMX084320M0001 Rated Rated Pole distvoltage current ance mm Ident. no. Weight kg CSA Main switch with fuse base and snap action mechanismwithout fuse tripping CSA Main switch with latched snap action mechanism (KS-mechanism) NAL 4-6 150KSR NAL 4-12 150KSR NAL 4-6 210KSR NAL 4-12 210KSR NAL 13-6 170KSR NAL 13-12 170KSR NAL 13-6 210KSR NAL 13-12 210KSR NAL 13-6 235KSR NAL 13-12 235KSR NAL 27-6 235KSR NAL 27-12 235KSR NAL 27-6 275KSR NAL 27-12 275KSR NAL 34-6 360KSR NAL 34-8 360KSR Type 32 33 32 33 34 35 34 35 34 35 34 35 42 43 42 43 42 43 42 43 68 68 NALF 4-6 150KR NALF 4-6 210KR NALF 13-6 170K17R NALF 13-6 170K24R NALF 13-6 210K17R NALF 13-6 210K24R NALF 13-6 235K17R NALF 13-6 235K24R NALF 27-6 235K24R NALF 27-6 275K24R NALF 34-6 360KR NALF 34-8 360KR 4,16 4,16 13,8 13,8 13,8 13,8 13,8 13,8 27,6 27,6 34,5 34,5 600 600 600 600 600 600 600 600 600 600 600 800 150 210 170 170 210 210 235 235 235 275 360 360 1YMX084071M0001 1YMX084926M0001 1YMX084073M0002 1YMX084073M0001 1YMX088210M0002 1YMX088210M0003 1YMX084075M0001 1YMX084075M0002 1YMX184075M0001 1YMX084426M0001 1YMX084322M0001 1YMX084323M0001 39 39 42 42 42 42 51 51 51 51 68 68 CSA Main switch with fuse base and latched snap action mechanism, with fuse tripping NALF 4-6 150KSR NALF 4-6 210KSR NALF 13-6 170KSR NALF 13-6 210KSR NALF 13-6 235KSR NALF 27-6 235KSR NALF 27-6 275KSR NALF 34-6 360KSR NALF 34-8 360KSR 4,16 4,16 13,8 13,8 13,8 27,6 27,6 34,5 34,5 600 600 600 600 600 600 600 600 800 150 210 170 210 235 235 275 360 360 1YMX084081M0001 1YMX084931M0001 1YMX084083M0001 1YMX089210M0002 1YMX084085M0001 1YMX184085M0001 1YMX084431M0001 1YMX084325M0001 1YMX084326M0001 41 41 44 44 53 53 53 70 70 CSA Main switch with fuse base and stored spring energy mechanism, with fuse tripping NALF 4-6 150AR NALF 4-6 210AR NALF 13-6 170A17R NALF 13-6 170A24R NALF 13-6 210A17R NALF 13-6 210A24R NALF 13-6 235A17R NALF 13-6 235A24R NALF 27-6 235A24R NALF 27-6 275A24R NALF 34-6 360AR NALF 34-8 360AR 4,16 4,16 13,8 13,8 13,8 13,8 13,8 13,8 27,6 27,6 34,5 34,5 600 600 600 600 600 600 600 600 600 600 600 800 150 210 170 170 210 210 235 235 235 275 360 360 1YMX084091M0001 1YMX084936M0001 1YMX084093M0001 1YMX084093M0002 1YMX080210M0002 1YMX080210M0003 1YMX084095M0001 1YMX084095M0002 1YMX184095M0001 1YMX084436M0001 1YMX084328M0001 1YMX084329M0001 41 41 44 44 44 44 53 53 53 53 70 70 Fuse base type F for A/KS mechanism with fuse tripping Mounted on the pivot side F 12 12 F 12 12 F 12 12 F 17 17 F 17 17 F 24 24 F 24 24 F 24 24 F 36 36 F 40 40,5 Mounted on the opening side F 12 12 F 12 12 F 12 12 F 17 17 F 17 17 F 24 24 F 24 24 F 24 24 400/630 400/630 400/630 400/630 400/630 400/630 400/630 400/630 630/800 630/800 150 170 210 170 210 170 235 275 360 360 1YMX054195M0001 1YMX064195M0001 1YMX054976M0001 1YMX054196M0001 1YMX064196M0001 1YMX064197M0001 1YMX054197M0001 1YMX054476M0001 1YMX054335M0001 1YMX064335M0001 7 7 7 8 8 15 13 13 17 17 400/630 400/630 400/630 400/630 400/630 400/630 400/630 400/630 150 170 210 170 210 170 235 275 1YMX054200M0001 1YMX064200M0001 1YMX054978M0001 1YMX054201M0001 1YMX064201M0001 1YMX064202M0001 1YMX054202M0001 1YMX054478M0001 7 7 7 8 8 13 13 13 13 Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF Type Rated Rated Pole distvoltage kV current A ance mm Ident. no. Weight, kg Fuse base with 6 insulators for A/KS-mechanism incl. fuse tripping 12 12 12 17,5 17,5 24 24 24 Fig. 27 400/630/1250 400/630/1250 400/630/1250 400/630/1250 400/630/1250 400/630/1250 400/630/1250 400/630/1250 150 170 210 170 210 170 235 275 1YMX054205M0001 1YMX064205M0001 1YMX054974M0001 1YMX054206M0001 1YMX064206M0001 1YMX064207M0001 1YMX054207M0001 1YMX054474M0001 Fuse base with 6 insulators for A/KS-mechanism excl. fuse tripping 12 12 12 17,5 17,5 24 24 24 400/630/1250 400/630/1250 400/630/1250 400/630/1250 400/630/1250 400/630/1250 400/630/1250 400/630/1250 150 170 210 170 210 170 235 275 1YMX054185M0001 1YMX064185M0001 1YMX054972M0001 1YMX054418M0001 1YMX064418M0001 1YMX064187M0001 1YMX054187M0001 1YMX054472M0001 Fuse base with 6 insulations with double fuses 12 12 17,5 24 24 400/630/1250 400/630/1250 400/630/1250 400/630/1250 400/630/1250 150 210 170 235 245 1YMX343555M0001 1YMX343555M0004 1YMX343555M0002 1YMX343555M0003 1YMX343555M0005 Earthing switch type E for NAL without mechanical interlocking Fig. 28 Type Rated Rated Pole distvoltage kV current A ance mm Ident. no. Weight, kg Fuse base type F for K/A/KS mechanism without fuse tripping Mounted on the pivot side F 12 12 F 12 12 F 12 12 F 17 17,5 F 17 17,5 F 24 24 F 24 24 F 24 24 F 36 36 F 40 40,5 Mounted on the opening side F 12 12 F 12 12 F 12 12 F 17 17,5 F 17 17,5 F 24 24 F 24 24 F 24 24 F 36 36 F 40 40,5 14 400/630 400/630 400/630 400/630 400/630 400/630 400/630 400/630 630/800 630/800 150 170 210 170 210 170 235 275 360 360 1YMX054181M0001 1YMX064181M0001 1YMX054960M0001 1YMX054182M0001 1YMX064182M0001 1YMX064183M0001 1YMX054183M0001 1YMX054460M0001 1YMX054337M0001 1YMX064337M0001 7 7 7 8 8 13 13 13 17 17 400/630 400/630 400/630 400/630 400/630 400/630 400/630 400/630 630/800 630/800 150 170 210 170 210 170 235 275 360 360 1YMX054190M0001 1YMX064190M0001 1YMX054961M0001 1YMX054191M0001 1YMX064191M0001 1YMX064193M0001 1YMX054193M0001 1YMX054461M0001 1YMX054337M0001 1YMX064337M0001 7 7 7 8 8 13 13 13 17 17 For switch disconnector type NAL E 12 12 400/630 E 12 12 400/630 E 12 12 400/630 E 12 12 1250 E 12 12 1250 E 12 12 1250 E 17 17,5 400/630 E 17 17,5 400/630 E 17 17,5 1250 E 17 17,5 1250 E 24 24 400/630 E 24 24 400/630 E 24 24 400/630 E 24 24 1250 E 24 24 1250 E 24 24 1250 For fuse base NALF E 12 12 400/630 E 12 12 400/630 E 12 12 400/630 E 17 17,5 400/630 E 17 17,5 400/630 E 24 24 400/630 E 24 24 400/630 E 24 24 400/630 150 170 210 150 170 210 170 210 170 210 170 235 275 170 235 275 1YMX054235M0001 1YMX064235M0001 1YMX054983M0001 1YMX054214M0001 1YMX064235M0002 1YMX054989M0001 1YMX054236M0001 1YMX064236M0001 1YMX054218M0001 1YMX064236M0002 1YMX064237M0001 1YMX054237M0001 1YMX054483M0001 1YMX064237M0002 1YMX054219M0001 1YMX054489M0001 7 7 7 7 7 7 8 8 8 8 9 9 9 9 9 9 150 170 210 170 210 170 235 275 1YMX054225M0001 1YMX064225M0001 1YMX054988M0001 1YMX054226M0001 1YMX064226M0001 1YMX064227M0001 1YMX054227M0001 1YMX054488M0001 7 7 7 8 8 9 9 9 Earthing switch type EB for separate installation EB 12 EB 12 EB 12 EB 17 EB 17 EB 24 EB 24 EB 24 EB 36 EB 36 Pivot s. NAL EB 36 Open s. NAL EB 36 Pivot s. NALF EB36Opens.NALF 12 12 12 17,5 17,5 24 24 24 36 36 36 36 36 1250 1250 1250 1250 1250 1250 1250 1250 800 630/800 630/800 630/800 630/800 150 170 210 170 210 235 170 275 360 360 360 360 360 1YMX054270M0001 1YMX064270M0001 1YMX054271M0001 1YMX054272M0001 1YMX064272M0001 1YMX054273M0001 1YMX064273M0001 1YMX054274M0001 1YMX054288M0001 1YMX344033M0001 1YMX344034M0001 1YMX344035M0001 1YMX344036M0001 17,5 17,5 17,5 19 19 24 24 24 30 30 30 30 30 ABB Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF Description Type Ident. no. Wt, kg 1YMX053233M0001 1YMX053233M0002 1YMX042249M0004 1YMX053362M0001 1YMX053235M0001 1YMX053235M0004 1YMX053393M0001 1YMX053394M0001 1YMX053395M0001 1YMX053396M0001 1YMX053397M0001 1YMX053398M0001 1.6 0.8 1,6 1.4 0.6 1,8 2.1 2.1 2.1 2.1 2.1 2.1 1YMX054357M0001 1YMX054353M0001 1YMX054358M0002 1YMX054358M0001 1YMX054359M0001 1YMX054355M0001 1YMX343226M0004 1YMX000054M0001 1YMX053346M0008 1YMX053346M0009 1YMX053346M0010 1YMX053346M0002 1YMX053347M0001 1YMX000012M0001 1YMX000012M0002 1YMX000012M0003 1YMX000012M0004 1YMX000012M0005 1YMX000012M0006 1YMX000012M0007 1YMX000012M0008 1YMX000004M0003 1YMX000004M0004 1YMX000004M0007 1YMX000004M0008 1YMX053225M0001 1YMX053001M0001 1YMX053348M0001 1YMX053349M0001 1YMX053350M0001 1YMX053351M0001 1YMX053352M0001 1YMX053353M0001 1YMX053354M0001 1YMX053355M0001 1YMX053356M0001 1.9 2.3 2.1 2.1 2.6 3.1 4.0 0,1 0,8 0,9 1,0 1,9 2,9 2,1 3,1 2,9 4,2 1,2 1,3 2,9 4,2 2,7 4,0 2,7 4,0 Hand operating mechanism type HE with accessories Front bearing for HE, with cardanic joint Front bearing for HE, without cardanic joint Front bearing for HE, for motor operating Bevel gear for HE Operating handle for HE Operating handle for HE, armoured Front bearing for HE, with blocking coil, 220 V AC Front bearing for HE, with blocking coil, 110 V AC Front bearing for HE, with blocking coil, 220 V DC Front bearing for HE, with blocking coil, 110 V DC Front bearing for HE, with blocking coil, 48 V DC Front bearing for HE, with blocking coil, 24 V DC Shaft extension for left-hand side operation: – for pole distance 150 mm – for pole distance 210 mm – for pole distance 170 mm (12 kV) – for pole distance 170 mm (17,5 and 24 kV) – for pole distance 235 mm – for pole distance 275 mm – for pole distance 360 mm Connection kit for shaft extension assembing Connection rod 490 mm Connection rod 550 mm Connection rod 570 mm Connection rod 1300 mm Connection rod 2000 mm Connection rod 1300 mm, insulated Connection rod 2000 mm, insulated Connection rod 1300 mm, armoured and insulated Connection rod 2000 mm, armoured and insulated Connection rod 668 mm, insulated CZ Connection rod 738 mm, insulated CZ Connection rod 1300 mm, armoured and insulated CZ Connection rod 2000 mm, armoured and insulated CZ Connection rod 1300 mm, armoured Connection rod 2000 mm, armoured Connection rod 1300 mm, armoured CZ Connection rod 2000 mm, armoured CZ Crank arm Operating rod Shaft extension 470 mm Shaft extension 380 mm Joint link for shaft extension Support bearing for NAL/NALF 12 Support bearing for NAL/NALF 17/24 Support bearing for NAL 12 with E 12 Support bearing for NAL 17/24 with E 17/24 Support bearing for F 12 with E 12 Support bearing for F 17/24 with E 17/24 Test fuse Adjustable length 3, 6/36 kV with striker pin Fig. 29 Fig. 30 Fig. 31 Fig. 32 Fig. 33 Fig. 34 Fig. 35 0.7 1.7 1.4 0.2 1.8 1.9 2.2 2.8 1.3 1.4 1YMX300062M0001 Mechanical interlocking for earthing switch *) 14. OPERATING EQUIPMENT AND OPTIONS Description Type Ident. no. Wt, kg Mechanisms K-mechanism K-mechanism K-mechanism K-mechanism K-mechanism A-mechanism A-mechanism A-mechanism A-mechanism A-mechanism KS-mechanism*) KS-mechanism*) KS-mechanism KS-mechanism Plastic cover for A-mechanism ABB K 12 K 17 K 24 K 36 K 40 A 12 A 17 A 24 A 36 A 40 KS 12/17 KS 24 KS 36 KS 40 1YMX054165M0001 5 1YMX038658M0001 5 1YMX054167M0001 5 1YMX054340M0001 5 1YMX054340M0001 5 1YMX054173M0001 7 1YMX054174M0001 7 1YMX054175M0001 7 1YMX051341M0001 7 1YMX051341M0001 7 1YMX054168M0001 6 1YMX054171M0001 6 1YMX054342M0001 6 1YMX054342M0001 6 1YMX241351M0001 0,2 – on NAL 12 – on NAL 17/24 – on NALF 12 Fuse length dim. e = 292 mm – on NALF 12 Fuse length dim. e = 192 mm – on NALF 12 Fuse length dim. e = 442 mm – on NALF 17 Fuse length dim. e = 292 mm – on NALF 17 Fuse length dim. e = 442 mm – on NALF 24 Fuse length dim. e = 442 mm – on NALF 24 Fuse length dim. e = 537 mm – on NAL 36/40 RB on pivot side – on NAL 36/40 RB on opening side – on NALF 36/40 RB on pivot side – on Nale 36/40 RB on opening side 1YMX054275M0001 1YMX054276M0001 1YMX054277M0001 1YMX054278M0001 1YMX054279M0001 1YMX054280M0001 1YMX054281M0001 1YMX054282M0001 1YMX054283M0001 1YMX343986M0002 1YMX343986M0001 1YMX343986M0003 1YMX343986M0004 2,5 3,1 5,7 5,0 6,4 6,3 7,0 6,5 7,3 5,4 3,3 9,4 7,6 *) Normally, interlocking is mounted on the left hand side of the switch and therefore a shaft for left hand operation is needed. Fig. 29 A-mechanism Fig. 30 K-mechanism Fig. 31 KS-mechanism Fig. 32 Front bearing for HE Fig. Bevel gear for HE Fig. 34 Mechanical interlocking Fig. 35 Auxiliary switch 15 Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF Description Ident. no. Weight, kg 1YMX054713M0001 1YMX054714M0001 1YMX054715M0001 1YMX054716M0001 1YMX054716M0002 1YMX054717M0001 1YMX054717M0002 1YMX240807M0005 1YMX240807M0006 1YMX054715M0001 1YMX240807M0004 1YMX053390M0001 0.9 1.0 1.1 0.9 0.9 1.0 1.0 0.9 1.0 1.1 0.1 0.1 Auxiliary switch for switch and earthing switch Fig. 36 Auxiliary switch 2no + 2nc for NAL/NALF 12-24 Auxiliary switch 4no + 4nc for NAL/NALF 12-24 Auxiliary switch 8no + 8nc for NAL/NALF 12-24 Auxiliary switch 2no + 2nc for E/EB 12-24 Auxiliary switch 2no + 2nc for E/EB 36 Auxiliary switch 4no + 4nc for E/EB 12-24 Auxiliary switch 4no + 4nc for E/EB 36 Auxiliary switch 2no + 2nc for NAL/NALF 36 Auxiliary switch 4no + 4nc for NAL/NALF 36 Auxiliary switch 8no + 8nc for NAL/NALF 36 Fixing materials for NAL/NALF 36 Auxiliary switch at fuse blown Shunt trip for A-mechanism Coil Coil Coil Coil Coil Coil 220 V AC without auxiliary switch 110 V AC without auxiliary switch 220 V DC without auxiliary switch 110 V DC without auxiliary switch 48 V DC without auxiliary switch 24 V DC without auxiliary switch incl. mounting materials 1YMX054740M0001 1YMX054741M0001 1YMX054742M0001 1YMX054743M0001 1YMX054744M0001 1YMX054745M0001 0.6 0.6 0.6 0.6 0.6 0.6 NOTE: In connection with shunt trip, auxiliary switch with indent no. 1YMX054713/54715 must be used. Spare coil for shunt trip for A-mechanism and coil for operating coil for KS-mechanism. Coil 220 V AC Coil 110 V AC Coil 220 V DC Coil 110 V DC Coil 48 V DC Coil 24 V DC Common separator for KS-mechanism 1YMX054250M0001 1YMX054251M0001 1YMX054252M0001 1YMX054253M0001 1YMX054254M0001 1YMX054255M0001 1YMX054257M0001 0.4 0.4 0.4 0.4 0.4 0.4 0.1 Fig. 36 Shunt trip 16 ABB Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF 15. DIMENSIONAL DRAWING 36 Switch disconnector type NAL 12, 17,5 and 24 kV with mechansim Type A A1 A2 A3 B H H1 H2 K K1 M N N1 P R S U V NAL 12-A/K/KS, NAL 12-A/K/KS, P=150 P=170 166 320 362 166 320 362 394 394 90 90 422 428 422 428 510 315 510 315 58 58 412 452 122 164 150 375 350 122 164 170 375 390 75 75 33 33 NAL 12-A/K/KS, P=210 166 320 362 394 90 422 428 510 315 58 532 122 164 210 375 470 75 33 NAL 17,5 A/K/KS, P=170 225 375 418 511 98 534 577 600 441 87 452 122 164 170 500 395 90 18 NAL 17,5-A/K/KS, P=210 225 375 418 511 98 534 577 600 441 87 532 122 164 210 500 470 90 18 NAL 24-A/K/KS, P=170 225 375 418 511 98 534 577 600 441 87 452 186 202 170 500 395 90 18 NAL 24 A/K/KS, P=235 225 375 418 511 98 534 577 600 441 87 582 186 202 235 500 525 90 18 NAL 24 A/K/KS, P=275 225 375 418 511 98 534 577 600 441 87 662 186 202 275 500 605 90 18 * 1250 A: A + 2 mm 36 Fuse switch disconnector type NALF 12 kV with mechanism Fuses kV Length 3,6/ 7,2 192 292 292 442 12 H1 H4 K2 K4 R1 R2 848 710 722 598 275 50 948 810 822 698 375 150 1098 960 972 848 525 300 Type NALF 12, P=150 NALF 12, P=170 NALF 12, P=210 ABB M S 412 350 452 390 532 470 17 Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF Fuse switch disconnector type NALF 17,5 kV with mechanism Fuses kV 17,5 H1 H4 292 1060 895 442 1210 1045 Length K2 K4 925 828 375 125 1075 978 525 275 Type NALF 17, P=170 NALF 17, P=210 R1 R2 M S 452 395 532 470 Fuse switch disconnector type NALF 24 kV with mechanism Fuses kV Length 24 442 537 H1 H4 K2 K4 R2 1194 1045 986 978 425 275 1284 1140 1090 1073 525 370 Type NALF 24, P=170 NALF 24, P=235 NALF 24, P=275 18 R1 M S 452 395 582 525 662 605 ABB Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF Fuses kV 3,6/7,2 12 17,5 24 Type E12, P=150 E12, P=170 E12, P=210 ABB M1 681 721 801 M2 428 468 548 S 350 390 470 Length H5 192 462 292 292 562 562 442 292 704 563 442 442 706 706 537 801 Type A5 A7 P NALF 12 – P = 150 NALF 12 – P = 170 NALF 17,5 – P = 170 NALF 24 – P = 170 NALF 17,5 – P = 210 NALF 12 – P = 210 NALF 24 – P = 235 NALF 24 – P = 275 173 173 243 243 243 173 243 243 430 430 500 500 500 430 500 500 150 170 170 170 210 210 235 275 Earthing switch with making capacity type E 12 mounted on NAL 12 Fuse switch disconnector type NALF 12, 17,5 and 24 kV Fuse base with 6 insulators Earthing switch with making capacitiy type E 12 mounted on fuse base F 12 19 Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF E 17,5 P 170 P 210 E 24 P=170 P=235 P=275 M1 721 801 M1 721 933 1013 M2 468 548 M2 468 598 678 S 395 475 S 395 525 605 Earthing switch with making capacity type E 17,5 mounted on NAL 17,5 kV N2 114 161 163 N3 139 174 174 Earthing switch with making capacity type E 24 mounted on NAL 24 kV Earthing switch with making capacity type E 24 mounted on fuse base F 24 Type Earthing switch with making capacity type E 12, E 17,5 and E 24 mounted on fuse base with 6 insulators 20 Earthing switch with making capacity type E 17,5 mounted on fuse base F 17,5. E 12 E 12 E 17,5 E 24 E 17,5 E 24 E 24 P = 150 P = 170 P = 170 P = 170 P = 210 P = 235 P = 275 H2 208 208 208 208 208 351 351 H3 393 393 393 432 432 575 575 K3 100 100 100 100 100 100 100 M1 681 721 721 721 801 933 1013 M2 428 468 468 468 548 598 678 N2 112 112 112 112 112 161 161 N3 139 139 139 139 139 174 174 P S 150 170 170 170 210 235 275 350 390 395 395 395 525 605 T W 375 60 375 60 375 60 375 60 375 60 500 120 500 120 ABB Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF Type EB 12 EB 17,5-24 A H K R U 245 310 231 245 115 90 200 175 46 21 Separately mounted earthing switch with making capacity type EB Recess in front Manual operation type HE Operating angle 180° 1YMX053362M0002 Transmission 46 Connection rod 1YMX053233M0001 46 90° 100 for A/K mech 1YMX400840M0001 1YMX053302M0002 1YMX343036M0001 for aplication with k mechanism only ABB 1YMX000129M0005 21 Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF Fuse kV 7,2 12 H1 H2 K2 R1 192 848 772 1063 722 275 292 292 948 872 1163 822 375 292 292 948 872 1163 822 375 442 1098 1098 1022 1313 972 525 Length e 192 H3 NAL 36 NAL 40,5 22 ABB Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF EB 36 NAL 36 + EB 36 NALF 36 + EB ABB 23 Triple-pole switch disconnector type NAL Fuse switch disconnector type NALF NALF 36 + EB ABB ABB Sp. z o.o. Power Products division ul. Leszno 59 06-300 Przasnysz, Poland Phone: (+48 22) 51 52 838, 51 52 831 (+48 29) 75 33 233, 75 33 240 Fax: +48 22 51 52 659, +48 29 75 33 327 e-mail: export.plzwa@pl.abb.com www.abb.com 24 ABB