PRODUCT DATA SHEET Protecting your technology investment. RMR Swing Wall-Mount Environmental Enclosure Coming soon from CPI: ADVANTAGES An environmentally advanced Provides NEMA 12 and IP 55 rated environmental protection for non-hazardous indoor locations using innovative gasket technology at each panel and cable entry point enclosure solution that extends data center management best practices beyond IT environments. Allows technicians quick access to the front and rear of equipment through a doublehinged, swing-out design The RMR Swing-Out Wall-Mount Enclosure is engineered to provide advanced sealing technology, A broad offering of airflow and cooling options are available to maintain equipment cooling requirements outside of normal IT settings and equipment rooms certified environmental ratings and dual-sided access to IT, automation and control equipment in Supports high-density cable bundles by providing cable management options that route cables from front to rear, without invading excessive rack-mount unit (U) space non-hazardous indoor locations. A variety of design options enable easy personalization with short lead-times SPECIFICATIONS Industry Standards Cabinet Includes Overall Dimensions Equipment Space Load Ratings Industrial Control NEMA Type 12, IP 55 Enclosure is rated for indoor use and protects equipment against the ingress of dust, lint and other debris, as well as dripping and splashing from non-corrosive liquids. Enclosure with swing-out chassis and hinged, swing door Equipment mounting rails and/or mounting panels/personalized support options Metric hardware Heights: - 9U, 19.2” (486 mm) - 12U, 24.4” (620 mm) - 15U, 29.7” (753 mm) - 18U, 34.9” (886 mm) - 21U, 40.2” (1020 mm) - 26U, 48.9” (1242 mm) Widths: 23.6” (600 mm) and 27.6” (700 mm) Depths: 20.5” (520 mm), 24.4” (620 mm) and 29.9” (760 mm) 19" EIA (482.6 mm) Equipment Mounting Rails: Rear Mounting Panels 15.75”H – 31.5”H (9U – 18U): 110 lb (50 kg) 36.75”H and 45.5”H (21U and 26U): 250 lb (113 kg) Global Availability US & Canada +1-800-834-4969 Toronto, Ontario, Canada +905-850-7770 chatsworth.com techsupport@chatsworth.com Latin America +52-55-5203-7525 Toll Free within Mexico 01-800-01-7592 chatsworth.com.co Europe +44-1628-524-834 chatsworthproducts.co.uk Middle East & Africa Dubai, UAE +971-4-2602125 chatsworth.ae Asia Pacific +86 21 6880-0266 chatsworth.com.cn PRODUCT DATA SHEET RMR Swing Wall-Mount Environmental Enclosure SPECIFICATIONS Materials and Construction Doors Certifications/ Compliance Finishes Panels - Standard panels and doors are solid steel Sealing - All openings include formed-in-place foam gaskets to protect enclosure from solid and liquid ingress Door options include: - Solid metal door - Viewing door, tempered safety glass to resist impact - Multiple locking options NEMA Type 12 IP 55 RoHS Reach EIA-310-E (for 19”EIA equipment rails) Enclosure panels are welded, ground smooth and finished with an epoxy-polyester-hybrid powder coat of paint Color options: Black or Gray Additional finish options available upon request Description Wall-mounted, NEMA 12 and IP 55 rated environmental enclosure with hinged, three part design for IT, automation and control equipment Standard design features pre-punched holes in rear section for use with lag bolts or machine screws Installation Hardware washers feature gaskets and close fit mounting holes to maintain NEMA 12 and IP 55 ratings Mounting brackets available All equipment support options are electrically bonded to the frame and painted to match enclosure Enclosures are comprised of three sections: a rear section that mounts to the wall, a center section that hinges open, and a front door Each rear section includes (4) shoulder weld studs for attaching a rear mounting panel Each center section includes punched attachment points along the sides spaced on 1" (25 mm) depth increments and 1.75" (44.45 mm) height increments Equipment Support Adjustable-depth 19” EIA Rails: - Attaches to the center section of the enclosure - EIA-310-E Universal Hole Pattern - 1” (25 mm) front-to-back adjustment increments - 1.75” (44.45 mm) U vertical spacing - Square-punched or #12-24 tapped rails available Rear Equipment Mounting Panel - Attaches to the rear section of the enclosure Adjustable Depth Equipment Mounting Panel - Attaches inside the body of the enclosure - Other equipment support options available upon request Side Panels - Optional square-shaped fan/filter opening on each side panel for quick access installation access - Other penetration options available upon request Airflow/Ventilation Rear Section - Solid (no ventilation) - Upper and lower gland plates for fan/filter access - Non-rated brushes, sized to fit in place of gland plate - Other penetration options available upon request Chassis feature bonded construction with grounding studs on all major panels Grounding/Bonding Rear section includes a two-point connection for service Solutions grounding Grounding wires included on all enclosures Standard panels are solid Rear Section, top and bottom may include optional sealed Cable Entry openings with removable solid gland plates or brushed covers (brush covers change rating to NEMA Type 1) Cable tie slots located on the mounting rails Optional Short Finger Brackets Optional Cable Lashing Brackets Additional Accessories Optional Front-to-Rear Cable Lashing Bracket Accessory (for 700 mm wide enclosures) Kitting, personalization and optional preinstallation with accessory purchase Cabinet is comprised of a: -Rear Section -Center Section -Front Door Equipment mounting options include: -Rear Mounting Panel for Rear Section -Adjustable Depth Mounting Panel for Center Section -19"EIA mounting rails for Center Section 2 Chatsworth Products PRODUCT DATA SHEET RMR Swing Wall-Mount Environmental Enclosure PRODUCT INFORMATION NEMA 12 and IP 55 Rated Environmental Protection for Non-Hazardous Indoor Locations Chatsworth Products (CPI) RMR Swing-Out Wall-Mount Enclosure provides exceptional protection for network, communication, automation and control equipment in non-hazardous indoor locations. The RMR Swing-Out Wall-Mount Enclosure features welded steel panels with robotic, formed-in-place foam gaskets and optional sealed cable entry points. These features effectively maintain the enclosure’s NEMA 12 and IP 55 environmental ratings, which certify that equipment is protected from the intrusion of solid foreign objects such as dirt, dust, lint and fibers, as well as non-corrosive liquid ingresses such as light dripping and splashing. The RMR Swing-Out Wall-Mount Enclosure features a solid or windowed front door equipped with a CH751 key-latch for security purposes. In addition, the robust design of the RMR Swing-Out Wall-Mount Enclosure protects personnel from hazardous moving parts and electrical charges within the enclosure. While the standard Wall-Mount Enclosure is a completely sealed, solid enclosure, it features many modification possibilities, which are available with short lead times. Many filtered fan options are available to meet ventilation requirements, and multiple cable entry points and accessories are available for configuration with very little lead time. Accessible Three-Part Design The RMR Swing-Out Wall-Mount Enclosure features a three-part design, with a solid rear section, hinged center section and a solid or windowed front door, equipped with a CH751 key-latch for security purposes. The enclosure’s center section enables the front portion to release, swinging away from the wall section to provide front and rear access to interior equipment. This allows for quick installation and maintenance, which limits the amount of time that sensitive equipment is exposed to the environment. As a security measure, the center section of the RMR Swing-Out Wall-Mount Enclosure is only accessible when the front door is unlatched to prevent unauthorized access. Expanded Equipment Support All RMR Enclosures feature configurations that include 19” EIA rails or mounting panels. These options ensure compatibility with a number of electronic installations that extend beyond communications and network devices to include automation and control equipment. Attachment points are punched around the interior perimeter of the frame, providing top-to-bottom, front-to-back and side-to-side mounting locations for accessories. Additional mounting solutions are available upon request. Enhanced Cable Management Options The RMR Swing-Out Wall-Mount Enclosure provides environmental protection, while enabling data center industry best practices for cable support and management. The RMR Swing-Out Wall-Mount Enclosure features NEMA 12 and IP 55 rated cable entry options that include gland plates on each of the top and bottom panels. These entry points allow for optimal cable fill values that do not interfere with environmental ratings. Additional cable entry points are available upon request. Many of CPI’s top-rated accessories such as Finger Cable Mangers, Ring Cable Managers and Cable Lashing Brackets are available for the RMR Swing-Out Wall-Mount Enclosure. In addition, a Front-to-Rear Cable Lashing Bracket has been developed for use with the RMR Swing-Out Wall-Mount Enclosure. This new accessory attaches to the frame and aligns with each U space to provide a dedicated front-to rear-pathway, and prevents high volume cabling from dropping into the U space below. Quality Airflow with Enhanced Environmental Protection While the standard Swing-Out Wall-Mount Enclosure is a completely sealed enclosure for NEMA 12 and IP 55 ratings, CPI can modify the enclosure with openings for Filtered Fan Kits. These fan kits mount to the enclosure’s side panels, doors and top panel and are available in a range of airflow specifications and voltages. In addition, Active Cooling Options are available to meet a range of heat loads from to 900-1300 Btu/h (263-380 W). Modified Enclosures With NEMA 12 and IP 55 environmental ratings and features that integrate data center industry best practices, the Swing-Out Wall-Mount Enclosure allows organizations to extend their networks to the very edge of their expanding enterprise. Configure one for your growing network today by contacting CPI Tech Support. Interested in learning more about our RMR Environmental Enclosures? Call us at 800-834-4969 or email Technical Support at techsupport@chatsworth.com. 3 Chatsworth Products PRODUCT DATA SHEET RMR Swing Wall-Mount Environmental Enclosure ACCESSORIES Short Finger Brackets Short Finger Brackets attach alongside the equipment mounting rails to organize patch cords at each U space. • Plastic T-shaped fingers with openings that align with U space • May be installed on either side of the equipment rails • Includes: Bracket and installation hardware • Material: Steel bracket, plastic fingers Ring Cable Manager Ring Cable Manager organizes loose patch cords along the sides of the enclosure. • Plastic C-shaped rings have openings at front that support the easy addition and removal of patch and jumper cords • May be installed on either side of the enclosure frame • Includes: Bracket, rings and installation hardware • Material: Steel bracket, plastic rings Mounting Brackets Easy-to-use mounting brackets attach to the wall, allowing the enclosure to hook on and remain securely in place during the installation process. Brackets then act as an extra wall anchor once the enclosure is installed. Interior Light Interior Light aids technicians and personnel in installations, maintenance and other field activity. • Attaches to the bottom, top or side of enclosures • Fluorescent light with on/off switch Cable Lashing Bracket Cable Lashing Bracket secures multiple cable bundles along the side of the enclosure. • Attachment points along both sides of the cabinet • An array of slots compatible with zip-ties or Saf-T-Grip Cable Management Straps • May be installed in front of or behind the equipment mounting rails or on either side of the cabinet frame • Includes: Bracket and installation hardware (Order Saf-T-Grips or cable ties separately) Front-to-Rear Cable Manager Front-to-Rear Cable Lashing Bracket routes high volumes of cables from front-to-rear of the cabinet, preventing cabling from invading the U space below the cable run. • Attaches to the frame to provide a dedicated front to rear pathway • Includes: Trough and installation hardware • Material: Steel bracket Horizontal eConnect® PDUs Horizontal eConnect® Power Distribution Units (PDUs) are intelligent power distribution devices with control and monitoring capabilities. Horizontal eConnect PDUs feature dimensions that are scaled to deliver intelligent power distribution to smaller, space-limited enclosures. • Compatible with 19” EIA racks • LCD display • Branch/phase circuit breakers • Supports temperature ratings up to 149°F (65°C) • Built-in web interface to support remote monitoring and DCIM-integration that includes: - Remote PDU and branch/phase power monitoring (Monitored models) - Individual, remote outlet control options (Switched models) VENTILATION OPTIONS Filtered Fan Kits Filtered Fan Kits draw air into the enclosure, pressurizing the cabinet and forcing warm air out of the side vents. Use of the filter also reduces the occurrence of dust and contamination within the enclosure. • Square-shaped, 5”x 5” (125 mm x 125 mm) intake fan with filter, rated at 38 Cubic Feet per Minute (CFM), 115V • 120 VAC, 230 VAC, 24 VDC, 48 VDC options • Other fan/filter kit sizes, CFM and voltage options are available upon request Active Cooling Unit Side-mounted air conditioner to cool equipment within the enclosure. Able to perform efficiently in high temperature areas. Uses environmentally-friendly HFC-free R134a refrigerant and a hermetically sealed compressor to prevent refrigerant loss. Includes a backward curve impeller fan to optimizes airflow and extends service life. Wide condenser fin spacing reduces particulate clogging while balancing performance and condenser coils are coated with corrosion protection to extend service life. Also, actively evaporates condensation to remove moisture. • Size is 15.5"H x 7"W x 7.6"D (394 mm x 180 mm x 193 mm) • 900-1300 BTU (263-380 W), 115V Scan or click here to visit our CPI Online Catalog. Interested in learning more about our RMR Environmental Enclosures? Call us at 800-834-4969 or email Technical Support at techsupport@chatsworth.com. While every effort has been made to ensure the accuracy of all information, CPI does not accept liability for any errors or omissions and reserves the right to change information and descriptions of listed services and products. ©2016 Chatsworth Products, Inc. All rights reserved. Chatsworth Products, CPI, CPI Passive Cooling, eConnect, MegaFrame, Saf-T-Grip, Seismic Frame, SlimFrame, TeraFrame, GlobalFrame, CUBE-iT PLUS, Evolution, OnTrac, QuadraRack and Velocity are federally registered trademarks of Chatsworth Products. Simply Efficient and Secure Array are trademarks of Chatsworth Products. All other trademarks belong to their respective companies. 04/16 MKT-60020-664