RMR Swing Wall-Mount Environmental Enclosure

advertisement
PRODUCT DATA SHEET
Protecting your technology investment.
RMR Swing Wall-Mount Environmental Enclosure
Coming soon from CPI:
ADVANTAGES
An environmentally advanced
Provides NEMA 12 and IP 55 rated
environmental protection for non-hazardous
indoor locations using innovative gasket
technology at each panel and cable entry point
enclosure solution that extends
data center management best
practices beyond IT environments.
Allows technicians quick access to the front
and rear of equipment through a doublehinged, swing-out design
The RMR Swing-Out Wall-Mount
Enclosure is engineered to provide
advanced sealing technology,
A broad offering of airflow and cooling options
are available to maintain equipment cooling
requirements outside of normal IT settings
and equipment rooms
certified environmental ratings and
dual-sided access to IT, automation
and control equipment in
Supports high-density cable bundles by
providing cable management options that
route cables from front to rear, without
invading excessive rack-mount unit (U) space
non-hazardous indoor locations.
A variety of design options enable easy
personalization with short lead-times
SPECIFICATIONS
Industry Standards
Cabinet Includes
Overall Dimensions
Equipment Space
Load Ratings
Industrial Control NEMA Type 12, IP 55
Enclosure is rated for indoor use and protects equipment against the ingress of dust, lint and other debris,
as well as dripping and splashing from non-corrosive liquids.
Enclosure with swing-out chassis and hinged, swing door
Equipment mounting rails and/or mounting panels/personalized support options
Metric hardware
Heights:
- 9U, 19.2” (486 mm)
- 12U, 24.4” (620 mm)
- 15U, 29.7” (753 mm)
- 18U, 34.9” (886 mm)
- 21U, 40.2” (1020 mm)
- 26U, 48.9” (1242 mm)
Widths: 23.6” (600 mm) and 27.6” (700 mm)
Depths: 20.5” (520 mm), 24.4” (620 mm) and 29.9” (760 mm)
19" EIA (482.6 mm) Equipment Mounting Rails: Rear Mounting Panels
15.75”H – 31.5”H (9U – 18U): 110 lb (50 kg)
36.75”H and 45.5”H (21U and 26U): 250 lb (113 kg)
Global Availability
US & Canada
+1-800-834-4969
Toronto, Ontario, Canada
+905-850-7770
chatsworth.com
techsupport@chatsworth.com
Latin America
+52-55-5203-7525
Toll Free within Mexico
01-800-01-7592
chatsworth.com.co
Europe
+44-1628-524-834
chatsworthproducts.co.uk
Middle East & Africa
Dubai, UAE
+971-4-2602125
chatsworth.ae
Asia Pacific
+86 21 6880-0266
chatsworth.com.cn
PRODUCT DATA SHEET
RMR Swing Wall-Mount Environmental Enclosure
SPECIFICATIONS
Materials and
Construction
Doors
Certifications/
Compliance
Finishes
Panels
- Standard panels and doors are solid steel
Sealing
- All openings include formed-in-place foam gaskets to
protect enclosure from solid and liquid ingress
Door options include:
- Solid metal door
- Viewing door, tempered safety glass to resist impact
- Multiple locking options
NEMA Type 12
IP 55
RoHS
Reach
EIA-310-E (for 19”EIA equipment rails)
Enclosure panels are welded, ground smooth and finished with
an epoxy-polyester-hybrid powder coat of paint
Color options: Black or Gray
Additional finish options available upon request
Description
Wall-mounted, NEMA 12 and IP 55 rated environmental
enclosure with hinged, three part design for IT, automation and
control equipment
Standard design features pre-punched holes in rear section for
use with lag bolts or machine screws
Installation
Hardware washers feature gaskets and close fit mounting
holes to maintain NEMA 12 and IP 55 ratings
Mounting brackets available
All equipment support options are electrically bonded to the
frame and painted to match enclosure
Enclosures are comprised of three sections: a rear section that
mounts to the wall, a center section that hinges open, and a
front door
Each rear section includes (4) shoulder weld studs for
attaching a rear mounting panel
Each center section includes punched attachment points along
the sides spaced on 1" (25 mm) depth increments and 1.75"
(44.45 mm) height increments
Equipment Support
Adjustable-depth 19” EIA Rails:
- Attaches to the center section of the enclosure
- EIA-310-E Universal Hole Pattern
- 1” (25 mm) front-to-back adjustment increments
- 1.75” (44.45 mm) U vertical spacing
- Square-punched or #12-24 tapped rails available
Rear Equipment Mounting Panel
- Attaches to the rear section of the enclosure
Adjustable Depth Equipment Mounting Panel
- Attaches inside the body of the enclosure
- Other equipment support options available upon request
Side Panels
- Optional square-shaped fan/filter opening on each side
panel for quick access installation access
- Other penetration options available upon request
Airflow/Ventilation
Rear Section
- Solid (no ventilation)
- Upper and lower gland plates for fan/filter access
- Non-rated brushes, sized to fit in place of gland plate
- Other penetration options available upon request
Chassis feature bonded construction with grounding studs on
all major panels
Grounding/Bonding
Rear section includes a two-point connection for service
Solutions
grounding
Grounding wires included on all enclosures
Standard panels are solid
Rear Section, top and bottom may include optional sealed
Cable Entry
openings with removable solid gland plates or brushed covers
(brush covers change rating to NEMA Type 1)
Cable tie slots located on the mounting rails
Optional Short Finger Brackets
Optional Cable Lashing Brackets
Additional Accessories Optional Front-to-Rear Cable Lashing Bracket Accessory
(for 700 mm wide enclosures)
Kitting, personalization and optional preinstallation with
accessory purchase
Cabinet is comprised of a:
-Rear Section
-Center Section
-Front Door
Equipment mounting options include:
-Rear Mounting Panel for Rear Section
-Adjustable Depth Mounting Panel for Center Section
-19"EIA mounting rails for Center Section
2
Chatsworth Products
PRODUCT DATA SHEET
RMR Swing Wall-Mount Environmental Enclosure
PRODUCT INFORMATION
NEMA 12 and IP 55 Rated Environmental Protection for Non-Hazardous Indoor Locations
Chatsworth Products (CPI) RMR Swing-Out Wall-Mount Enclosure provides exceptional protection for network, communication, automation and control equipment in
non-hazardous indoor locations. The RMR Swing-Out Wall-Mount Enclosure features welded steel panels with robotic, formed-in-place foam gaskets and optional sealed cable
entry points. These features effectively maintain the enclosure’s NEMA 12 and IP 55 environmental ratings, which certify that equipment is protected from the intrusion of solid
foreign objects such as dirt, dust, lint and fibers, as well as non-corrosive liquid ingresses such as light dripping and splashing. The RMR Swing-Out Wall-Mount Enclosure
features a solid or windowed front door equipped with a CH751 key-latch for security purposes. In addition, the robust design of the RMR Swing-Out Wall-Mount Enclosure
protects personnel from hazardous moving parts and electrical charges within the enclosure.
While the standard Wall-Mount Enclosure is a completely sealed, solid enclosure, it features many modification possibilities, which are available with short lead times. Many
filtered fan options are available to meet ventilation requirements, and multiple cable entry points and accessories are available for configuration with very little lead time.
Accessible Three-Part Design
The RMR Swing-Out Wall-Mount Enclosure features a three-part design, with a solid rear section, hinged center section and a solid or windowed front door, equipped with a
CH751 key-latch for security purposes. The enclosure’s center section enables the front portion to release, swinging away from the wall section to provide front and rear access
to interior equipment. This allows for quick installation and maintenance, which limits the amount of time that sensitive equipment is exposed to the environment. As a security
measure, the center section of the RMR Swing-Out Wall-Mount Enclosure is only accessible when the front door is unlatched to prevent unauthorized access.
Expanded Equipment Support
All RMR Enclosures feature configurations that include 19” EIA rails or mounting panels. These options ensure compatibility with a number of electronic installations that
extend beyond communications and network devices to include automation and control equipment. Attachment points are punched around the interior perimeter of the frame,
providing top-to-bottom, front-to-back and side-to-side mounting locations for accessories. Additional mounting solutions are available upon request.
Enhanced Cable Management Options
The RMR Swing-Out Wall-Mount Enclosure provides environmental protection, while enabling data center industry best practices for cable support and management. The
RMR Swing-Out Wall-Mount Enclosure features NEMA 12 and IP 55 rated cable entry options that include gland plates on each of the top and bottom panels. These entry
points allow for optimal cable fill values that do not interfere with environmental ratings. Additional cable entry points are available upon request.
Many of CPI’s top-rated accessories such as Finger Cable Mangers, Ring Cable Managers and Cable Lashing Brackets are available for the RMR Swing-Out Wall-Mount
Enclosure. In addition, a Front-to-Rear Cable Lashing Bracket has been developed for use with the RMR Swing-Out Wall-Mount Enclosure. This new accessory attaches to the
frame and aligns with each U space to provide a dedicated front-to rear-pathway, and prevents high volume cabling from dropping into the U space below.
Quality Airflow with Enhanced Environmental Protection
While the standard Swing-Out Wall-Mount Enclosure is a completely sealed enclosure for NEMA 12 and IP 55 ratings, CPI can modify the enclosure with openings for Filtered
Fan Kits. These fan kits mount to the enclosure’s side panels, doors and top panel and are available in a range of airflow specifications and voltages. In addition, Active Cooling
Options are available to meet a range of heat loads from to 900-1300 Btu/h (263-380 W).
Modified Enclosures
With NEMA 12 and IP 55 environmental ratings and features that integrate data center industry best practices, the Swing-Out Wall-Mount Enclosure allows organizations to
extend their networks to the very edge of their expanding enterprise. Configure one for your growing network today by contacting CPI Tech Support.
Interested in learning more about our RMR Environmental Enclosures? Call us at 800-834-4969
or email Technical Support at techsupport@chatsworth.com.
3
Chatsworth Products
PRODUCT DATA SHEET
RMR Swing Wall-Mount Environmental Enclosure
ACCESSORIES
Short Finger Brackets
Short Finger Brackets attach alongside the equipment
mounting rails to organize patch cords at each U space.
• Plastic T-shaped fingers with openings that align with
U space
• May be installed on either side of the equipment rails
• Includes: Bracket and installation hardware
• Material: Steel bracket, plastic fingers
Ring Cable Manager
Ring Cable Manager organizes loose patch cords along
the sides of the enclosure.
• Plastic C-shaped rings have openings at front that
support the easy addition and removal of patch and
jumper cords
• May be installed on either side of the enclosure frame
• Includes: Bracket, rings and installation hardware
• Material: Steel bracket, plastic rings
Mounting Brackets
Easy-to-use mounting brackets attach to the wall,
allowing the enclosure to hook on and remain securely in
place during the installation process. Brackets then act as
an extra wall anchor once the enclosure is installed.
Interior Light
Interior Light aids technicians and personnel in
installations, maintenance and other field
activity. • Attaches to the bottom, top or side of enclosures
• Fluorescent light with on/off switch
Cable Lashing Bracket
Cable Lashing Bracket secures multiple cable bundles
along the side of the enclosure.
• Attachment points along both sides of the cabinet
• An array of slots compatible with zip-ties or Saf-T-Grip
Cable Management Straps
• May be installed in front of or behind the equipment
mounting rails or on either side of the cabinet frame
• Includes: Bracket and installation hardware (Order
Saf-T-Grips or cable ties separately)
Front-to-Rear Cable Manager
Front-to-Rear Cable Lashing Bracket routes high volumes
of cables from front-to-rear of the cabinet, preventing
cabling from invading the U space below the cable run.
• Attaches to the frame to provide a dedicated front to
rear pathway
• Includes: Trough and installation hardware
• Material: Steel bracket
Horizontal eConnect® PDUs
Horizontal eConnect® Power Distribution Units (PDUs) are
intelligent power distribution devices with control and
monitoring capabilities. Horizontal eConnect PDUs feature
dimensions that are scaled to deliver intelligent power
distribution to smaller, space-limited enclosures.
• Compatible with 19” EIA racks
• LCD display
• Branch/phase circuit breakers
• Supports temperature ratings up to 149°F (65°C)
• Built-in web interface to support remote monitoring
and DCIM-integration that includes:
- Remote PDU and branch/phase power monitoring
(Monitored models)
- Individual, remote outlet control options
(Switched models)
VENTILATION OPTIONS
Filtered Fan Kits
Filtered Fan Kits draw air into the enclosure, pressurizing
the cabinet and forcing warm air out of the side vents.
Use of the filter also reduces the occurrence of dust and
contamination within the enclosure.
• Square-shaped, 5”x 5” (125 mm x 125 mm) intake fan
with filter, rated at 38 Cubic Feet per Minute (CFM),
115V
• 120 VAC, 230 VAC, 24 VDC, 48 VDC options
• Other fan/filter kit sizes, CFM and voltage options are
available upon request
Active Cooling Unit
Side-mounted air conditioner to cool equipment within
the enclosure. Able to perform efficiently in high
temperature areas. Uses environmentally-friendly
HFC-free R134a refrigerant and a hermetically sealed
compressor to prevent refrigerant loss. Includes a
backward curve impeller fan to optimizes airflow and
extends service life. Wide condenser fin spacing reduces
particulate clogging while balancing performance and
condenser coils are coated with corrosion protection
to extend service life. Also, actively evaporates
condensation to remove moisture.
• Size is 15.5"H x 7"W x 7.6"D
(394 mm x 180 mm x 193 mm)
• 900-1300 BTU (263-380 W), 115V
Scan or click here to visit
our CPI Online Catalog.
Interested in learning more about our RMR Environmental Enclosures? Call us at 800-834-4969
or email Technical Support at techsupport@chatsworth.com.
While every effort has been made to ensure the accuracy of all information, CPI does not accept liability for any errors or
omissions and reserves the right to change information and descriptions of listed services and products.
©2016 Chatsworth Products, Inc. All rights reserved. Chatsworth Products, CPI, CPI Passive Cooling, eConnect, MegaFrame,
Saf-T-Grip, Seismic Frame, SlimFrame, TeraFrame, GlobalFrame, CUBE-iT PLUS, Evolution, OnTrac, QuadraRack and Velocity
are federally registered trademarks of Chatsworth Products. Simply Efficient and Secure Array are trademarks of
Chatsworth Products. All other trademarks belong to their respective companies. 04/16 MKT-60020-664