Comprehensive USB 3.1 Test Suite Datasheet

advertisement
Comprehensive
USB
3.0 Test Suite
Comprehensive
USB 3.1
Test Suite
Key Features
• Single vendor solution for the full
Teledyne LeCroy is the only vendor which offers a full line of USB 3.1 test
• Fully automated Transmitter and
receiver tests are covered in one automated physical layer test package,
range of USB 3.1 tests
Receiver testing
• Transmitter Testing
– Support for Gen1 and Gen2 DUTs
– Automated compliance pattern
–
(CP) change with PeRT3
Seamless SigTest integration
• Receiver Testing
– Automated Rx calibration
– True protocol handshake support
– Jitter Tolerance Testing
– USB 3.1 Compliance Patterns
• Protocol Testing
– Multi-function analyzer system –
–
with integrated USB 3.1 exerciser
Support for Type-C, USB 3.1, and Power Delivery 2.0
T.A.P.3™ probing for fast signal
lock, seamless state change
detection and accurate
LFPS detection
• Cable and Connector Testing
– S-parameters and TDR testing
– Insertion loss, crosstalk,
–
impedance measurements
Measures from DC up to 40 GHz
solutions for compliance, characterization, and debug. Transmitter and
QPHY-USB3.1-Tx-Rx, enabling streamlined testing. The M310C protocol
analyzer can test the link layer for protocol compliance. Cables and
connectors can be quickly characterized using the SPARQ Series Network
Analyzer for S-parameter and TDR testing. Teledyne LeCroy provides the
right solution for every stage of USB 3.1 development.
Transmitter Testing
Protocol Testing
QPHY-USB3-Tx-Rx offers a fully
Supporting the Type-C, 3.1 and Power
automated compliance test package
Delivery 2.0 specifications, the Voyager
for USB 3.1 transmitter compliance
USB analyzer platform provides the
testing. Tests can be performed using
industry’s most accurate capture of
the latest SigTest software for official
the USB protocol. This multifunction
compliance results. Alternatively, tests
validation platform is available with an
can be run using SDAIII to provide the
integrated exerciser providing host and
ideal interface for debugging any
device emulation.
USB 3.1 failures.
Cable and Connector Testing
Receiver Testing
The SPARQ Series Network Analyzer
The PeRT (Protocol-enabled
can easily make all frequency and time
Receiver and Transmitter Tolerance
domain measurements required for
Tester) fills the space between
USB 3.1 cable and connector testing.
physical layer test and protocol test,
The SPARQ performs S-parameter
providing a new and more intelligent
measurements at a fraction of
capability for performance testing of
the cost of a VNA and utilizes a
receivers and transmitters.
built-in calibration kit to make all
3
measurements quickly and easily.
COMPREHENSIVE DEBUG AND COMPLIANCE
Successful development of new USB 3.1 products requires a coordinated end-to-end test program to cover all aspects
of the USB 3.1 design. For transmitter testing it is essential to verify eye diagrams, jitter, and other performance
measurements. Receiver testing plays a vital role in ensuring reliable data transfer. When designing reliable channels,
cables and connectors it is critical to perform S-parameter and TDR testing. Finally, no design is complete without
verifying the protocol layer to ensure functionality and compliance to USB 3.1 requirements.
The Right Solution for
Every Stage of Development
Furthermore, these uniquely integrated
Teledyne LeCroy’s test tools cover the
test solutions combine test capabilities
full range of test needs: industry-
Teledyne LeCroy is the only vendor
at multiple levels and merge the results
leading oscilloscopes for transmitter
which offers a complete line of USB 3.1
for more accurate and meaningful
testing, protocol analyzers and
test solutions covering transmitter
information.
excercisers to cover all USB speeds
test to protocol test, and every step
in between for comprehensive
verification, debug and compliance.
All USB 3.1 testing can be
accomplished with a single point of
procurement and support.
2
Experience and leader­ship in providing
high-speed serial data test tools make
Teledyne LeCroy the natural choice as a
test partner for USB 3.1 development.
and Power Delivery, and unique
products such as the Protocol-enabled
Receiver and Transmitter Tolerance
Tester (PeRT 3 ), and SPARQ network
analyzers for S-parameter
measurements and TDR testing.
Challenges with Adopting USB 3.1
Developed and promoted through the
The USB 3.1 Compliance Test
The increased transfer rate coupled
USB Implementers Forum (USB-IF),
Specification requires the use of
with the smaller size of the new
USB has been long established as
reference channels and Continuous
Type-C connector creates
the interconnect system of choice
Time Linear Equalization (CTLE) and
complications for USB 3.1 cable and
for peripheral systems.
Decision Feedback Equalization (DFE)
connector designs. It is now imperative
equalization schemes for compliance
to properly characterize cable and
measurements. The Eye Doctor™ II
connector designs
USB 3.1 doubles the maximum data
transfer rate from 5 Gb/s to 10 Gb/s,
enables enhanced power capabilities
(up to 100 W), and introduces the
Type-C connector platform. Each of
analysis package has the ability to
emulate the reference channel and the
CTLE/DFE as specified.
The added Power Delivery functionality
will provide widespread benefits for
consumers; however, it greatly
these new features require new design
In addition to increasing the transfer
complicates protocol level design. The
approaches, high quality manufacturing
rate, USB 3.1 implements a new
Voyager M310C includes full support
processes, and comprehensive testing
128b/132b encoding scheme. In order
for USB 3.1 and the USB Power Delivery
and debug procedures to achieve
to effectively test and debug USB 3.1
2.0 specifications.
reliable data transfer and
receivers, the PeRT3 offers true SKP
interoperability.
symbol injections and SKP filtering
.
during BER testing, as well as
128b/132b pattern generation
and detection.
3
TRANSMITTER COMPLIANCE TESTING AND DEBUG
Key Features
• QPHY-USB3.1-Tx-Rx offers fully
automated transmitter and
receiver testing
• Support for both Gen1 (5 Gb/s)
and Gen2 (10 Gb/s) DUTs
• Automatically change DUT
compliance patterns using the
PeRT3
• SigTest software is fully
integrated into the oscilloscope
software
• QPHY-USB3-Tx-Rx provides full
Combining the power of the SDA 8 Zi-B Oscilloscope with the unique features of the PeRT3
creates the perfect test setup for USB 3.1 transmitter (Tx) testing.
Automated Transmitter Testing
Using the PeRT3 for Tx Testing
reporting capability including
QPHY-USB3.1-Tx-Rx offers a fully
While other vendors require you to
Pass/Fail indications and
automated test package for USB 3.1
purchase a separate piece of
screenshots from pertinent tests
transmitter compliance testing,
equipment to request the DUT to
characterization, and debug. It provides
output the required compliance pattern
connection diagrams to ensure the
(CP), the PeRT3, which is used for Rx
proper setup for the required
testing, can be used for this purpose,
measurements, automates the
reducing the required investment and
oscilloscope for performing these
simplifying the setup.
• Eye Doctor™ II Advanced Signal
Integrity Tools enable channel
emulation and CTLE/DFE
equalization
• SDAIII-CompleteLinQ enables
measurements, and provides a
simultaneous analysis of
comprehensive report of results
multiple points in the USB 3.1
including pass/fail results and
channel
screenshots.
QPHY-USB3.1-Tx-Rx can control the
PeRT3 communication with the DUT on
the protocol layer by sending a specific
number of Ping.LFPS commands in
QPHY-USB3.1-Tx-Rx uses all of the
order to stimulate it to output the
powerful oscilloscope features to
required CP for each test. This enables
perform the transmitter compliance
fully automated transmitter
tests as described by the USB 3.1 base
compliance testing. Alternatively, the
specification and draft electrical
QPHY-USB3.1-Tx-Rx script can prompt
compliance test specification.
the user to manually change the CP,
which can be useful for DUTs early in
the design stage which don’t yet have
full protocol support implemented.
QualiPHY USB 3.1 Test Coverage
Low Frequency Periodic Signaling (LFPS)
Spread Spectrum Test
Jitter
Phase Jitter Slew Rate
4
Eye Diagram
AC and DC Common Mode Voltage
Differential Voltage
De-emphasis
QualiPHY
QualiPHY is designed to reduce the time, effort, and ­specialized
knowledge needed to perform compliance testing on high-speed
serial buses.
•
•
Guides the user through each test setup
Performs each measurement in accordance with the r­ elevant
test procedure
•
Compares each measured value with the applicable
­specification limits
•
•
Fully documents all results
QualiPHY helps the user perform testing the right way —
every time
Compliance Reports contain all of the tested values,
the specific test limits and screen captures. Compliance
Reports can be ­created as HTML, PDF or XML.
Complete SigTest Support
Advanced Debug Tools
SigTest is the official software
The Eye Doctor II analysis software
Multi-Point Simultaneous
Analysis
provided by the USB-IF for compliance
enables channel emulation and
SDAIII-CompleteLinQ is capable of
testing. By incorporating SigTest into
receiver equalization. For testing
simultaneously analyzing multiple
QPHY-USB3.1-Tx-Rx, pre-compliance
USB 3.1 at the far end of the channel,
lanes. This enables either looking at
testing can be confidently performed
a design engineer has the option of
the Host or Device transmitted signals
prior to attending a USB-IF workshop.
using a physical channel or they can
at different stages of the transmission
QPHY will automatically pass
use channel emulation to see what
path or multiple transmit lanes on a
waveforms to SigTest and incorporate
their serial data signal would look like if
Hub. Four “lanes” of analysis are
the results in the complete
it had been transmitted through the
available, allowing users to analyze
QualiPHY report.
channel. It is possible to experiment
data streams from different locations
with the multiple CTLE and DFE
in their USB channel(s). For example,
QPHY-USB3.1-Tx-Rx extends beyond
combinations from the USB 3.1
Lane 1 can show the Tx output, Lane 2
SigTest to provide a number of
standard or to define a custom CTLE
can show the signal at the far end of
informative tests which aren’t covered
for debugging purposes.
an emulated channel, Lane 3 can show
in SigTest. Tests which are covered in
SigTest can also be run using Teledyne
LeCroy’s SDAIII software which easily
lends itself to debugging any failures
whereas SigTest is rather limited.
Additionally, when using the SDAIII
software to measure eye diagrams or
perform jitter measurements, the
specific PLL for USB 3.1 is selectable
from a list of pre-configured PLLs
or the user can chose to define a
custom PLL.
the equalized far end signal, and Lane
4 the far end signal with a different
CTLE/DFE equalization scheme. Plots
are displayed using LaneScape
Comparison Mode, a unique display
capability that compares results from
1, 2 or all lanes at a time.
5
RECEIVER COMPLIANCE TESTING AND CHARACTERIZATION
Key Features
• QPHY-USB3.1-Tx-Rx offers fully
automated transmitter and
receiver testing
• Automated receiver calibration
process reduces complexity and
saves time during testing
• True protocol handshake support
in PeRT3 for loopback
initialization and TSEQ training
during receiver compliance
testing
• Bit Error Rate tester with
protocol aware capabilities
• Jitter Tolerance Testing for
characterization
• All pass/fail results documented
in QualiPHY report
• Built in 3 tap de-emphasis
generator
•
The QPHY-USB3.1-Tx-Rx framework will automate the Rx calibration procedure and control
the PeRT3 to perform receiver testing.
Receiver Compliance Testing
Automated Rx Test Calibration
The PeRT is designed to test receivers
Receiver test specifications require
under conditions of stress by starting
calibration of the jitter output sources
with a clean signal and gradually
for the test instrument. When using the
introducing measured levels of a variety
PeRT3 in conjunction with a Teledyne
of different stress types into the signal,
LeCroy oscilloscope, this calibration is
3
and simultaneously monitoring the
done automatically by the QPHY-
User defined test scripting
bit error rate (BER) to explore the full
USB3.1-Tx-Rx application.
functions for jitter tolerance,
performance envelope of the
equalization optimization
receiver system.
search, and multi-parameter
sweep testing
Following the calibration procedure,
the transmitter of the PeRT3 can be
The PeRT3 can be used in a stand alone
routed through the compliance test
mode or in conjunction with QPHY-
channel to the oscilloscope. The
USB3.1-TX-RX. QPHY-USB3.1-Tx-Rx is
QualiPHY framework will automate
able to control the PeRT to automate
the calibration process adjusting the
the loopback initiation process. Once
output of the PeRT3 depending upon
the device is in loopback, QPHY-
what is measured on the oscilloscope.
USB3.1-Tx-Rx will perform the
Performing this calibration process
mandated test for receiver compliance.
by hand would be extremely
3
time consuming.
QualiPHY USB 3.1 Test Coverage
Gen1 - Long Channel Jitter Tolerance
Gen1 - Short Channel Jitter Tolerance
Gen1 - LFPS Rx Test
6
Gen2 - Long Channel Jitter Tolerance
Gen2 - Short Channel Jitter Tolerance
Simple, intuitive interface for creating automated test scripts.
Protocol Aware
Jitter Tolerance Testing
Ease of Use
PeRT Phoenix System supports all the
All signal source and jitter parameters
With a single integrated system, the
jitter and equalization generation
can be swept during BER testing. For
PeRT3 replaces up to 6–8 other
required of USB 3.1, as well as the
example, by sweeping the de-emphasis
instruments. PeRT3 greatly simplifies
protocol level handshake that is critical
and pre-shoot values, the user can
experimental setup, increases the ease
to put the device under test into proper
identify the optimized equalization
of designing and conducting fully
test modes and optimal equalization
window. Each connect sequence
automated testing. It provides specific
conditions. PeRT3 Phoenix System also
provides the user with a list of options to test suites to ensure receiver
offers true SKP symbol injections and
customize the test criteria and
compliance to USB 3.1 specifications.
SKP filtering during BER testing, as well
debugging conditions. Pass/Fail
The simple, intuitive interface for
as 128b/132b pattern generation and
information is plotted against the stress
creating automated test scripts can,
detection. It also adds support for the
parameters under test. See what
with a few clicks, set up automated
newly defined USB 3.1 compliance
happened for every test case —
tests that initialize the DUT and record
patterns.
in real-time.
error rates while sweeping through any
3
user defined range of jitter parameters.
7
CABLE AND CONNECTOR COMPLIANCE AND DEBUG
Key Features
• Complete S-parameter
measurements up to four ports
• Measures from DC up to
40 GHz
• One-button-press operation
using built-in OSLT calibration
• Returns both frequency and time
domain results
• Produces "simulation-ready"
mixed-mode and single-ended
S-parameters
• Includes advanced
de-embedding features
• Inherent TDR/TDT capability and
preview modes for quick checks
and debugging
• Available at a fraction of the
cost of other network analyzer
solutions
SPARQ Signal Integrity Network Analyzer can easily perform frequency and time domain
measurements for USB 3.1 cable and connector testing.
Cable/Connector Testing
S-parameters with just a single button
USB 3.1 connector and cable tests that
press, and at a fraction of a cost of a
measure insertion loss, impedance and
VNA. Fully calibrated measurements
crosstalk measurements can be
can be made in minutes, and without
performed with the Teledyne LeCroy
any need to connect or disconnect
SPARQ Signal Integrity Network
cables to calibration standards or
Analyzer. SPARQ is a TDR/TDT-based
electronic calibration modules.
analyzers that easily measures
Tests Performed by the SPARQ Include:
Differential Impedance
Intra-pair skew
Differential Insertion Loss
Mated Connector Impedance
Differential Insertion Loss
D+/D- Pair Propagation Delay Skew
Differential Near-End and Far--End Crosstalk, SuperSpeed and Gen2 Pairs
Differential Near-End and Far--End Crosstalk, D+/D- and SuperSpeed Pairs
D+/D- Propagation Delay and Skew
Differential to Common-mode Conversion
D+/D- Pair Attenuation
8
Calibrated impedance measurements are available with selectable rise time. This feature provides impedance measurements
of connectors, cables, and backplanes.
S-parameter Measurements
Flexible Measurements
Fixture De-embedding
S-parameter measurements are at the
All measurements can be made in
Fixtures are easily de-embedded using
heart of the characterization and
both single-ended and mixed-mode
time-domain gating. All of these
verification of passive components, and
configurations, yielding differential
features are standard.
are needed to validate models and for
insertion loss, crosstalk and impedance
simulations. At less than half of the
measurements needed for
price of a VNA, the SPARQ is an ideal
USB 3.1 Tx/Rx and cable testing.
instrument for your lab. S-parameter
Results are “simulation ready”, using
measurements are taken quickly and
optional passivity, reciprocity and
easily by utilizing the industry’s first
causality enforcements, and include
built-in OSLT calibration kit. The SPARQ
a DC point, something that cannot
performs calibration automatically,
be done with a VNA.
without any user intervention,
eliminating the frustration VNA users
have with error-prone manual
calibration procedures, while also
eliminating the need for expensive
“ECAL” modules. In addition to
S-parameter results, SPARQ calculates
step and impulse responses and
De-embedding cable test fixtures is
required when testing USB 3.1 cable
performance. SPARQs can de-embed
cable test fixtures with a time-domain
gating procedure that does not require
any separate USB 3.1 TRL or OSLT
calibration fixtures. All that is required is
the USB 3.1 1x or 2x THRU structure.
Crosstalk between all three signal pairs
can be quickly characterized using a
12-port SPARQ. With a single 12-port
measurement, NEXT and FEXT between
the six differential ports can be
measured. SPARQ models are available
ranging from 2 through 12 ports.
Rho and Z profiles normalized to a
user’s risetime.
9
PROTOCOL COMPLIANCE TESTING AND VERIFICATION
Key Features
• Captures 2.0, 3.0 and 3.1
protocol traffic concurrently.
• USB Power Delivery 2.0 support
• Interface for Type-C or standard
connectors
• Integrated 3.1 Exerciser
• 16 GB Recording Memory
• Turnkey Protocol layer
Compliance Test Suite
• Power Tracker Option provides
graphical display of VBus
Voyager M310C provides traffic generation and recording of USB 3.1, 3.0, and 2.0 to perform
protocol compliance testing and verification.
measurements and protocol
traffic simultaneously
USB Protocol Verification
configurations and is upgradeable to
The Voyager M310C is Teledyne
3.1. There is an integrated exerciser
LeCroy’s USB protocol verification
option supporting both host and device
system designed for the latest
emulation that allows error injection
evolutions of universal serial bus,
functionality and compliance
USB 3.1, Type-C and USB Power
verification. The Voyager M310C
Delivery 2.0. Leveraging Teledyne
platform has up to 16 GB of recording
LeCroy’s extensive expertise in high-
memory plus both GBe and
speed serial data analysis, the Voyager
SuperSpeed USB data upload ports for
M310C provides traffic generation and
fast access to captured traffic.
recording of USB 3.1, 3.0 and 2.0 at
data rates up to 10 Gb/s. Utilizing the
USB industry’s de facto CATC Trace and
loaded with innovative features that
help uncover elusive protocol errors, the
Voyager platform is the intelligent
The Voyager M310C features custom
probe technology known as T.A.P.3
(Transparent Acquisition Probing)
which has been field proven in Teledyne
choice for USB Type-C 3.1 validation.
LeCroy’s market-leading PCIe 3.0 and
Flexible Hardware
intrusively record both 5 and 10 Gbps
SAS 12G analyzers. Designed to non-
The Voyager M310C is a true
links, T.A.P.3 technology provides
multifunction platform capable of 10G
unprecedented accuracy and reliability
USB 3.1, 3.0 and 2.0 protocol
without compromising link integrity.
verification. It is available in 3.0
10
Unmatched Accuracy
Link Tracker shows
bi-directional data
stream in raw 10-bit or
hex format
Complete
decoding of
USB logical
transaction
and transfer
layers
Automatic decoding of
upper level protocols
Quick Click
timing
calculations
are always
visible
Power Tracker transparently measures and displays
voltage and current to verify power management
USB Power Delivery 2.0
Event and Error reports are
generated automatically for
every trace
Verifying Power Management
The M310C captures all “CC” events
Automated Compliance
Reports
over the CC wire in the USB Type-CTM
The Compliance Suite provides “one-
is implemented at the link layer which
cables. In addition, power
button” operation that manages the
adds new behaviors that must be
measurements of voltage, current and
Voyager test system and runs the
thoroughly tested. The Voyager
power on VBus are captured. Support
verification software. After each test
M310C records and timestamps all
for USB Power Delivery 2.0 is enhanced
case is run, the system displays a
upstream and downstream power
with the Voyager M310C Power
pass/fail result. If a test should fail, the
state changes. The Compliance Suite
Tracker™ option. Power Tracker
system can automatically save trace
adds specific test cases that verify
provides a time based graphical display
files to help users identify root cause
power management protocol including
of VBus measurements and helps
issues. Markers with a description of
proper entry and exit.
users correlate actual power usage
the error are automatically inserted on
with logical link state changes.
the packet in question. Reports can be
USB 3.1 power management support
generated in HTML, XML or text. Full
source code is provided allowing
individual scripts to be modified for
custom verification tasks.
11
SDA 816Zi-B Oscilloscope
16 GHz, 80 GS/s, 128 Mpts/Ch Serial Data Analyzer with 15.3" WXGA Color Display,
50 Ω and 1 MΩ Input
Eye Doctor Advanced Signal Integrity Tools
QualiPHY Enabled USB 3.1 Software Option
USB 3.0 and USB 3.1 Test Fixture Set (“A” male, “A” female, “B” female)
Upgrade Bundle - Multi-Lane SDA LinQ Framework, including Eye, Jitter, Noise,
Crosstalk Measurements, with EyeDrII & VirtualProbe
32 GB RAM Upgrade (recommended with purchase of SDA8Zi-CompleteLinQ)
SDA 816Zi-B
WM8Zi-EYEDRII
QPHY-USB3.1-Tx-Rx
TF-USB3
SDA8Zi-CompleteLinQ
WM8Zi-8-UPG-32GBRAM
r
e c to
C onn
Cabl
e and
Transmitter Test
ol
Product Code
Proto
c
Product Description
Elec
and Rtrical Tra
eceiv nsmit
te r
er
ORDERING INFORMATION
z
z
z
z
•
•
Receiver Test
PeRT3 Platform
Phoenix PeRT3 System – 1 Channel
10 Gb/s Options for PeRT3 Phoenix
PER-R008-S01-X
PER-R008-10G-A
Phoenix Receiver Tolerance Test Suite
PER-R006-008-A
Phoenix USB 3.0 Receiver Test Suite
USB-R008-001-A
Phoenix USB 3.1 Receiver Test Suite
USB-R008-PLS-A
z
z
z
z
z
S-parameter and TDR Tests
SPARQ Signal Integrity Network Analyzer
30 GHz, 4-port, Internal Calibration, Signal Integrity Network Analyzer
30 GHz, 12-port, Internal Calibration, Signal Integrity Network Analyzer
Signal Integrity Studio Software Option
z
SPARQ-3004E
SPARQ-3012E
SPARQ-SISTUDIO
••
Protocol Test
Voyager Analyzer Systems
Voyager M310
USB-TZP3-V04-X
Voyager M310C
Voyager USB 3.1 Compliance Suite
Voyager USB 3.1 Power Tracker Option
USB-TZP3-V06-X
USB-AC15-V01-A
USB-AC04-V01-A
•z
z
•
z Indicates required for compliance testing.
• Indicates recommended for debug.
Accessories
Pair of ±1 ps Matched SMA-SMA Cables 12 Inches
Pair of ±1 ps Matched SMA-SMA Cables 18 Inches
1-800-5-LeCroy
teledynelecroy.com
Matched-SMA-Cables-12inch-Pair
Matched-SMA-Cables-18inch-Pair
Local sales offices are located throughout the world.
Visit our website to find the most convenient location.
© 2015 by Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change
without notice. Product or brand names are trademarks or requested trademarks of their respective holders.
usb3.1testsuite-ds-23mar15
Download