Service unit combinations LFR-K/LFRS-K, D series Service unit combinations LFR-K/LFRS-K, D series, metal design Product range overview D series service units, metal design Type Service units FRC/FRCS Service unit combinations FRC-K LFR-K LFRS-K Individual devices Filter regulators LFR/LFRS Filters LF Fine and micro filters LFMA/LFMB Active carbon filters LFX Filter combinations LFMBA Pressure regulators LR/LRS 2 Size Pneumatic connection Pressure regulation range [bar] Grade of filtration [μm] M5 M7 Gx G¼ Gy G½ G¾ G1 QS4 QS6 0.5 … 7 Micro Mini Midi Maxi n – – – n – – – n n – – – n n – – n n – – – n n – – n n – – – n n – – – n – – – n n n n – n n n – – – – – – – – – – – – n n n n – n n n Micro Mini Midi Maxi Micro Mini Midi Maxi – – – – – – – – – – – n – – n n – – n – – n n – – n – – – – – – – – – – – – n n n n n n – – – – – – – – – n n n – – – n – – n n – – n – – n n – – n – – – – – – – – – – – – n n n n n n – – – – – – – – – n n n Micro Mini Midi Maxi n – – – n – – – n n – – – n n – – n n – – – n n – – n n – – – n n – – – n – – – n n n n – n n n – – – – – – – – – – – – n n n n – n n n Micro Mini Midi Maxi Micro Mini Midi Maxi Micro Mini Midi Maxi Micro Mini Midi Maxi n – – – – – – – – – – – – – – – n – – – n n – – – n n – – n n – – – n n – – n n – – – n n – – – n – – – – – – – – – – – – – – – – – – – – – – – n n n n – n n n – – – n – – n n – n n – – n n – n n – – n – – – – – – – – – – – – – – – n n n n n n – – – – – – – – – n – – n n – n n – – n n – n n – – n – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – n – – n n – n n – – n n – n n – – n – – – – – – – – – – – – – – – n n n n n n – – – – – – Micro Mini Midi Maxi n – – – n – – – n n – – – n n – – n n – – – n n – – n n – – – n n – – – n – – – n n n n – n n n – – – – – – – – – – – – – – – – – – – – è Internet: www.festo.com/catalogue/... 0.5 … 12 2.5 … 12 0.01 1 5 40 Subject to change – 2015/04 Service unit combinations LFR-K/LFRS-K, D series, metal design Product range overview D series service units, metal design è Page/ Internet Rotary knob with detent Rotary knob with integrated lock 24 V DC 110 V AC 230 V AC Differential pressure indicator Without pressure gauge Directly actuated pressure regulator with integrated return flow function Pilot actuated pressure regulator with integrated return flow function Options With pressure gauge Actuator lock Supply voltage Fully automatic Pressure indication Semi-automatic Condensate drain Manual rotary Micro Mini Midi Maxi Bowl guard Plastic bowl Service units FRC/FRCS Size Metal bowl guard Type – n n n n – – – n n n n n – – – – n n n n n n n n n n n n n n n – n n n – – – – – – – – – – – – – – – n – – – n – – – – – – – n n n – – – n n n n n n – – – n n n – – – n n n – – – – – – – – n – – n – – – – – – n n n – – – n n n n n n – – – n n n n n n n n n – – – – – – – – n – – n – – – frc Service unit combinations FRC-K Micro Mini Midi Maxi LFR-K Micro LFRS-K Mini Midi Maxi – n n n – n n n Individual devices Filter Micro regulators Mini LFR/LFRS Midi Maxi – n n n n – – – n n n n n – – – – n n n n n n n n n n n n n n n – n n n – – – – – – – – – – – – – – – n – – – n – – – – lfr Micro Mini Midi Maxi Fine and micro Micro filters Mini LFMA/LFMB Midi Maxi Active carbon Micro filters Mini LFX Midi Maxi Filter Micro combinations Mini LFMBA Midi Maxi – n n n – n n n – n n n – n n n n – – – n n n n n – – – – n n n – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – lf – – – n n n – – – n n n – – – – – – – – – – – – – – – – – – – – – – – – – – – n n n – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – n n n – – – n n n – – – – – – – – – – – – – – – – – – – – – – – – – – – n n n Pressure regulators LR/LRS – – – – – – – – – – – – – – – – – – – – n n n n n n n n n n n n – n n n – – – – – – – – – – – – – n n n – – – n – – – – Filters LF Micro Mini Midi Maxi 2015/04 – Subject to change frc 6 lfma, lfmb lfx lfmba è Internet: www.festo.com/catalogue/... lr 3 Service unit combinations LFR-K/LFRS-K, D series, metal design Product range overview D series service units, metal design Type Size Pneumatic connection M5 Individual devices Pressure regulators LRB/LRBS Pressure regulation range [bar] M7 Gx G¼ Gy G½ G¾ G1 QS4 QS6 0.5 … 7 – – – – n – – n – – – – – – – – – – n n n n – – – – n – n n – n – – – – – – – – n n n n n – – – n n – – – n n – – n n – – – n n – – n n – – – n n – – – n – – – – – – – – – – – – – – n – – n n – n n – – n n – n n – – n – – – – – – – – – – – – – – – n – – n n – n n – – n n – n n – – n – – – – – – – – – – – – – – – n – – n n – n n – – n n – n n – – n – – – – – – – – – – – – – – – n – – n n – n n – – n n – n n – – n – – – – – – – – – – – – 0.5 … 12 Micro Mini Midi Maxi Micro Mini Midi Maxi – – – – – – – – Lubricators LOE Micro Mini Midi Maxi n – – – On-off valves HE Micro Mini Midi Maxi Micro Mini Midi Maxi Micro Mini Midi Maxi Micro Mini Midi Maxi – – – – – – – – – – – – – – – – Micro Mini Midi Maxi – – – – – – – – n n n – – – – Micro Mini Midi Maxi Micro Mini Midi Maxi – – – – – – – – – – – – – – – n – – – – – – n n – – – – – n n – – – – – – n n – – – – – n n – – – – – – n – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – Pressure regulator combinations LRB-K On-off valves, electrical HEE On-off valves, pneumatic HEP Soft-start valves HEL Membrane air dryers LDM1 Branching modules FRM Distributor block FRZ 4 è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 Service unit combinations LFR-K/LFRS-K, D series, metal design Product range overview D series service units, metal design è Page/ Internet 24 V DC 110 V AC 230 V AC Non-return function Pressure switch Options Rotary knob with integrated lock Supply voltage Rotary knob with detent – – – – – – – – Actuator lock Without pressure gauge Individual devices Pressure Micro regulators Mini LRB/LRBS Midi Maxi Pressure Micro regulator Mini combinations Midi LRB-K Maxi Pressure indication With pressure gauge Bowl guard – – – – – n n n n n n – – – – – – – – – – – – – – – n n n n – – – – – – – – – – – – n – – – – – – – n n n n – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – n n n n n n – – – – – – – – – – – – – – – – – – – – – – – – n n n – – – – – – n n n n n n n n n – – – – – – – – – – – – n n n – – – – – – – – – – – – – – – – – – – – – – – – – – – n n n – – – – – – – – – – – – – – – – – – – – – Plastic bowl Size Metal bowl guard Type lrb lrb Lubricators LOE Micro Mini Midi Maxi – n n n On-off valves HE Micro Mini Midi Maxi Micro Mini Midi Maxi Micro Mini Midi Maxi Micro Mini Midi Maxi – – – – – – – – – – – – – – – – Micro Mini Midi Maxi – – – n – – n – – – – – – – Micro Mini Midi Maxi Micro Mini Midi Maxi – – – – – – – – – – – – – – – – – – – – – – n n n n n n n – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – n n n – – – – n n n – – – – On-off valves, electrical HEE On-off valves, pneumatic HEP Soft-start valves HEL Membrane air dryers LDM1 Branching modules FRM Distributor block FRZ 2015/04 – Subject to change loe he hee hep hel ldm1 frm è Internet: www.festo.com/catalogue/... frz 5 Service unit combinations LFR-K/LFRS-K, D series, metal design Product range overview LFR Rotary knob with detent KA Individual devices On-off valve manually actuated Filter regulator with pressure gauge Branching module On-off valve solenoid actuated, 24 V DC Soft-start valve pneumatically actuated Branching module with pressure switch Mounting bracket è Page/Internet KB KE KF KG n n – – n n n n n n n n n n n – – – – – – – – n – – n – – – n – – n – – – – n n n n n n n n n n 9 13 17 21 25 29 33 P m P m G1/2 G1/2 G1/2 G1/2 KA Individual devices On-off valve manually actuated Filter regulator with pressure gauge Branching module On-off valve with solenoid actuated, 24 V DC Soft-start valve pneumatically actuated Branching module with pressure switch Mounting bracket 6 KD – LFRS Rotary knob with integrated lock è Page/Internet KC 9 KB KC KD KE KF KG – n n – – n n n n n n n n n n n – – – – – – – – n – – n – – – n – – n – – – – n n n n n n n n n n 13 17 è Internet: www.festo.com/catalogue/... 21 25 29 33 Subject to change – 2015/04 Service unit combinations LFR-K/LFRS-K, D series, metal design Peripherals overview -H- 1 Note The choice of accessories depends on the selected service unit com­ bination. The example shows the service unit combination LFR-KG. This combination can also be ob­ tained with a lockable rotary regu­ lator as service unit combination LFRS-KG. 1 2 1 Range of accessories è Peripherals pages of the indi­ vidual devices 6 5 4 3 Mounting attachments and accessories è Page/ Internet 1 lrvs-d 2 3 4 5 6 – Regulator lock LRVS Padlock LRVS Plug socket MSSD-C Angled plug socket PEV-…-WD-LED Plug socket with cable KMEB-1 Plug socket MSSD-EB Filter cartridge LFP 2015/04 – Subject to change lrvs-d 49 49 49 49 48 è Internet: www.festo.com/catalogue/... 7 Service unit combinations LFR-K/LFRS-K, D series, metal design Type codes LFR — ½ — D — DI — MAXI — KA — A Basic function LFR LFRS Service unit combination Service unit combination, lockable Pneumatic connection x ¼ y ½ ¾ Thread Gx Thread G¼ Thread Gy Thread G½ Thread G¾ Series D Series Function (LFR and MAXI size only) DI Directly actuated pressure regulator with integrated return flow function Size MINI MIDI MAXI Grid dimension for individual device 40 mm (without connecting plates) Grid dimension for individual device 55 mm (without connecting plates) Grid dimension for individual device 66 mm (without connecting plates) Options for service unit combinations KA KB KC KD KE KF KG Filter regulator, branching module On-off valve manually actuated, filter regulator, branching module On-off valve manually actuated, filter regulator Filter regulator, on-off valve solenoid actuated, 24 V DC, soft-start valve pneumatically actuated Filter regulator, branching module with pressure switch On-off valve manually actuated, filter regulator, branching module with pressure switch On-off valve manually actuated, filter regulator, on-off valve solenoid actuated, 24 V DC, soft-start valve pneumatically actuated, branching module with pressure switch Condensate drain A 8 Turned manually Fully automatic è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 Service unit combinations LFR-KA/LFRS-KA, D series, metal design Technical data combination LFR-KA/LFRS-KA LFR/LFRS-…-MINI/MIDI-KA With condensate drain manual rotary -M-Q-L- Flow rate 720 … 9,400 l/min Temperature range –10 … +60 °C Operating pressure 1 … 16 bar LFR/LFRS-…-MAXI-KA With condensate drain manual rotary For unlubricated compressed air supply Three branch connections are available New filter cartridges è 48 Filter regulator LFR/LFRS Branching module FRM Mounting accessories General technical data Size Pneumatic connection 1, 2 Type of mounting Assembly position Grade of filtration Air purity class at the output Bowl guard Condensate drain Actuator lock Pressure regulation range Max. hysteresis Pressure indication Max. condensate volume Mini Midi Maxi Gx G¼ G¼ Gy G½ G½ G¾ Via accessories In-line installation Vertical ±5° [μm] 40 Compressed air in accordance with ISO 8573­1:2010 [7:8:4] (Compressed air in accordance with ISO 8573­1:2010 [6:8:4])1) Inert gases Metal bowl guard Manual rotary Fully automatic Rotary knob with detent Rotary knob with integrated lock [bar] 0.5 … 12 [bar] 0.15 0.15 0.25 0.2 0.2 0.2 0.3 Via pressure gauge [cm3] 22 43 80 (43)1) 1) For the LFR-…-D-DI. -H- Note: This product conforms to ISO 1179-1 and to ISO 228-1 Standard nominal flow rate qnN1) [l/min] Connection Mini Gx G¼ Midi G¼ Gy G½ Maxi G½ G¾ In main flow direction 1 > 2 1,140 1,850 2,620 3,050 9,200 (5,200)2) 9,400 (5,800)2) 1) 2) 720 Measured at p1 = 10 bar, p2 = 6 bar and Δp = 1 bar. For the LFR-…-D-DI. 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 9 Service unit combinations LFR-KA/LFRS-KA, D series, metal design Technical data combination LFR-KA/LFRS-KA Operating and environmental conditions Condensate drain Manual rotary Operating pressure Operating medium [bar] Ambient temperature [°C] Temperature of medium [°C] Corrosion resistance class CRC1) Certification 1) Fully automatic 1 … 16 2 … 12 Compressed air in accordance with ISO 8573­1:2010 [–:–:–] Inert gases –10 … +60 –10 … +60 2 Germanischer Lloyd Corrosion resistance class CRC 2 to Festo standard FN 940070 Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo­ sphere typical for industrial applications. Weight [g] Size Mini Midi Maxi LFR LFRS 800 900 1,800 2,040 2,400 (2,600)1) 2,500 1) For the LFR-…-D-DI. -H- Note Materials è Technical data of the individual devices p2 [bar] Standard flow rate qn as a function of the output pressure p2 LFR-½-D-DI-MAXI-KA(-A) qn [l/min] Primary pressure p1 = 10 bar 10 è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 Service unit combinations LFR-KA/LFRS-KA, D series, metal design Technical data combination LFR-KA/LFRS-KA Download CAD data è www.festo.com Dimensions LFR/LFRS-…-KA lockable Turned manually condensate drain Fully automatic condensate drain 3 Installation dimensions Type Mini LFR-…-D-MINI-KA (A) LFRS-…-D-MINI-KA (A) Midi LFR-…-D-MIDI-KA (A) LFRS-…-D-MIDI-KA (A) Maxi LFR-…-D-MAXI-KA (A) LFRS-…-D-MAXI-KA (A) LFR-…-D-DI-MAXI-KA (A) è Flow direction B5 B6 D1 H1 H2 104 92 4.3 43 140 125 5.3 162 146 5.3 H3 L1 L2 L3 L4 L6 L7 L8 L9 L10 T1 T2 17.5 17.5 193 28 60 68 98 60 15 19 3 39 95 70 24.5 35.5 250 36.5 80 99 130 60 15 19 3 47 114 70 24.5 35.5 42 90 82 111 60 15 19 3 53 126 105 135 252 275 -H- Note: This product conforms to ISO 1179-1 and to ISO 228-1 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 11 Service unit combinations LFR-KA/LFRS-KA, D series, metal design Technical data combination LFR-KA/LFRS-KA Ordering data Rotary knob with detent, pressure gauge with outer scale in bar and inner scale in psi Size Connection Condensate drain turned manually Part No. Type Mini Gx G¼ G¼ Gy G½ G½ G¾ 185708 185710 185712 185714 185716 186040 185718 LFR-x-D-MINI-KA-A LFR-¼-D-MINI-KA-A LFR-¼-D-MIDI-KA-A LFR-y-D-MIDI-KA-A LFR-½-D-MIDI-KA-A LFR-½-D-MAXI-KA-A LFR-¾-D-MAXI-KA-A Directly actuated pressure regulator with integrated return flow function Maxi G½ 192440 LFR-½-D-DI-MAXI-KA G¾ 192447 LFR-¾-D-DI-MAXI-KA 192454 192461 LFR-½-D-DI-MAXI-KA-A LFR-¾-D-DI-MAXI-KA-A Ordering data Rotary knob with integrated lock, pressure gauge with outer scale in bar and inner scale in psi Size Connection Condensate drain turned manually Part No. Type Condensate drain fully automatic Part No. Type Midi Maxi Mini Midi Maxi 12 Gx G¼ G¼ Gy G½ G½ G¾ 185707 185709 185711 185713 185715 186039 185717 195008 195022 195036 195050 195064 195078 195092 LFR-x-D-MINI-KA LFR-¼-D-MINI-KA LFR-¼-D-MIDI-KA LFR-y-D-MIDI-KA LFR-½-D-MIDI-KA LFR-½-D-MAXI-KA LFR-¾-D-MAXI-KA Condensate drain fully automatic Part No. Type LFRS-x-D-MINI-KA LFRS-¼-D-MINI-KA LFRS-¼-D-MIDI-KA LFRS-y-D-MIDI-KA LFRS-½-D-MIDI-KA LFRS-½-D-MAXI-KA LFRS-¾-D-MAXI-KA è Internet: www.festo.com/catalogue/... 195009 195023 195037 195051 195065 195079 195093 LFRS-x-D-MINI-KA-A LFRS-¼-D-MINI-KA-A LFRS-¼-D-MIDI-KA-A LFRS-y-D-MIDI-KA-A LFRS-½-D-MIDI-KA-A LFRS-½-D-MAXI-KA-A LFRS-¾-D-MAXI-KA-A Subject to change – 2015/04 Service unit combinations LFR-KB/LFRS-KB, D series, metal design Technical data combination LFR-KB/LFRS-KB -M- LFR/LFRS-…-MINI/MIDI-KB With condensate drain manual rotary -Q-L- Flow rate 700 … 8,400 l/min Temperature range –10 … +60 °C Operating pressure 1 … 16 bar LFR/LFRS-…-MAXI-KB With condensate drain manual rotary For unlubricated compressed air supply Operating pressure can be opened and closed Three branch connections are available On-off valve HE manually actuated Filter regulator LFR/LFRS Branching module FRM Mounting accessories General technical data Size Pneumatic connection 1, 2 Type of mounting Assembly position Grade of filtration Air purity class at the output Bowl guard Condensate drain Actuator lock Pressure regulation range Max. hysteresis Pressure indication Max. condensate volume Mini Midi To ensure safe venting of the sys­ tem, an additional quick exhaust valve is necessary at the output of the service unit combination New filter cartridges è 48 Maxi Gx G¼ G¼ Gy G½ G½ G¾ Via accessories In-line installation Vertical ±5° [μm] 40 Compressed air in accordance with ISO 8573­1:2010 [7:8:4] (Compressed air in accordance with ISO 8573­1:2010 [6:8:4])1) Inert gases Metal bowl guard Manual rotary Fully automatic Rotary knob with detent Rotary knob with integrated lock [bar] 0.5 … 12 [bar] 0.2 0.2 0.25 0.35 0.35 0.1 0.2 Via pressure gauge [cm3] 22 43 80 (43)1) 1) For the LFR-…-D-DI. -H- Note: This product conforms to ISO 1179-1 and to ISO 228-1 Standard nominal flow rate qnN1) [l/min] Connection Mini Gx In main flow direction 1 > 2 1) 2) 700 G¼ 1,050 Midi G¼ 1,720 Gy 2,420 G½ Maxi G½ G¾ 2,920 8,000 (5,400)2) 8,400 (7,000)2) Measured at p1 = 10 bar, p2 = 6 bar and Δp = 1 bar. For the LFR-…-D-DI. 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 13 Service unit combinations LFR-KB/LFRS-KB, D series, metal design Technical data combination LFR-KB/LFRS-KB Operating and environmental conditions Condensate drain Manual rotary Operating pressure Operating medium [bar] Ambient temperature [°C] Temperature of medium [°C] Corrosion resistance class CRC1) Certification 1) Fully automatic 1 … 16 2 … 12 Compressed air in accordance with ISO 8573­1:2010 [–:–:–] Inert gases –10 … +60 –10 … +60 2 Germanischer Lloyd Corrosion resistance class CRC 2 to Festo standard FN 940070 Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo­ sphere typical for industrial applications. Weight [g] Size Mini Midi Maxi LFR LFRS 1,000 1,100 2,200 2,440 3,300 (3,500)1) 3,400 1) For the LFR-…-D-DI. -H- Note Materials è Technical data of the individual devices p2 [bar] Standard flow rate qn as a function of the output pressure p2 LFR-½-D-DI-MAXI-KB(-A) qn [l/min] Primary pressure p1 = 10 bar 14 è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 Service unit combinations LFR-KB/LFRS-KB, D series, metal design Technical data combination LFR-KB/LFRS-KB Download CAD data è www.festo.com Dimensions LFR/LFRS-…-KB lockable 3 Installation dimensions Type Mini LFR-…-D-MINI-KB (A) LFRS-…-D-MINI-KB (A) Midi LFR-…-D-MIDI-KB (A) LFRS-…-D-MIDI-KB (A) Maxi LFR-…-D-MAXI-KB (A) LFRS-…-D-MAXI-KB (A) LFR-…-D-DI-MAXI-KB (A) è Flow direction B7 B8 D1 H1 H2 H3 L1 L2 L3 L4 L6 L7 L9 L10 T1 T2 144 132 4.3 43 17.5 17.5 193 28 60 68 98 60 19 3 39 95 195 180 5.3 70 24.5 35.5 250 36.5 80 99 130 60 19 3 47 114 228 212 5.3 70 24.5 35.5 42 90 82 111 60 19 3 53 126 105 135 252 275 -H- Note: This product conforms to ISO 1179-1 and to ISO 228-1 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 15 Service unit combinations LFR-KB/LFRS-KB, D series, metal design Technical data combination LFR-KB/LFRS-KB Ordering data Rotary knob with detent, pressure gauge with outer scale in bar and inner scale in psi Size Connection Condensate drain turned manually Part No. Type Mini Gx G¼ G¼ Gy G½ G½ G¾ 185720 185722 185724 185726 185728 186042 185730 LFR-x-D-MINI-KB-A LFR-¼-D-MINI-KB-A LFR-¼-D-MIDI-KB-A LFR-y-D-MIDI-KB-A LFR-½-D-MIDI-KB-A LFR-½-D-MAXI-KB-A LFR-¾-D-MAXI-KB-A Directly actuated pressure regulator with integrated return flow function Maxi G½ 192441 LFR-½-D-DI-MAXI-KB G¾ 192448 LFR-¾-D-DI-MAXI-KB 192455 192462 LFR-½-D-DI-MAXI-KB-A LFR-¾-D-DI-MAXI-KB-A Ordering data Rotary knob with integrated lock, pressure gauge with outer scale in bar and inner scale in psi Size Connection Condensate drain turned manually Part No. Type Condensate drain fully automatic Part No. Type Midi Maxi Mini Midi Maxi 16 Gx G¼ G¼ Gy G½ G½ G¾ 185719 185721 185723 185725 185727 186041 185729 195010 195024 195038 195052 195066 195080 195094 LFR-x-D-MINI-KB LFR-¼-D-MINI-KB LFR-¼-D-MIDI-KB LFR-y-D-MIDI-KB LFR-½-D-MIDI-KB LFR-½-D-MAXI-KB LFR-¾-D-MAXI-KB Condensate drain fully automatic Part No. Type LFRS-x-D-MINI-KB LFRS-¼-D-MINI-KB LFRS-¼-D-MIDI-KB LFRS-y-D-MIDI-KB LFRS-½-D-MIDI-KB LFRS-½-D-MAXI-KB LFRS-¾-D-MAXI-KB è Internet: www.festo.com/catalogue/... 195011 195025 195039 195053 195067 195081 195095 LFRS-x-D-MINI-KB-A LFRS-¼-D-MINI-KB-A LFRS-¼-D-MIDI-KB-A LFRS-y-D-MIDI-KB-A LFRS-½-D-MIDI-KB-A LFRS-½-D-MAXI-KB-A LFRS-¾-D-MAXI-KB-A Subject to change – 2015/04 Service unit combinations LFR-KC/LFRS-KC, D series, metal design Technical data combination LFR-KC/LFRS-KC -M- LFR/LFRS-…-MINI/MIDI-KC With condensate drain manual rotary -Q-L- Flow rate 750 … 8,400 l/min Temperature range –10 … +60 °C Operating pressure 1 … 16 bar LFR/LFRS-…-MAXI-KC With condensate drain manual rotary For unlubricated compressed air Operating pressure can be opened and closed On-off valve HE manually actuated Filter regulator LFR/LFRS Mounting accessories General technical data Size Pneumatic connection 1, 2 Type of mounting Assembly position Grade of filtration Air purity class at the output Bowl guard Condensate drain Actuator lock Pressure regulation range Max. hysteresis Pressure indication Max. condensate volume Mini Midi To ensure safe venting of the sys­ tem, an additional quick exhaust valve is necessary at the output of the service unit combination New filter cartridges è 48 Maxi Gx G¼ G¼ Gy G½ G½ G¾ Via accessories In-line installation Vertical ±5° [μm] 40 Compressed air in accordance with ISO 8573­1:2010 [7:8:4] (Compressed air in accordance with ISO 8573­1:2010 [6:8:4])1) Inert gases Metal bowl guard Manual rotary Fully automatic Rotary knob with detent Rotary knob with integrated lock [bar] 0.5 … 12 [bar] 0.2 0.2 0.2 0.2 0.2 0.2 0.2 Via pressure gauge [cm3] 22 43 80 (43)1) 1) For the LFR-…-D-DI. -H- Note: This product conforms to ISO 1179-1 and to ISO 228-1 Standard nominal flow rate qnN1) [l/min] Connection Mini Gx G¼ Midi G¼ Gy G½ Maxi G½ G¾ In main flow direction 1 > 2 1,150 1,900 2,700 3,150 8,100 (4,800)2) 8,400 (5,400)2) 1) 2) 750 Measured at p1 = 10 bar, p2 = 6 bar and Δp = 1 bar. For the LFR-…-D-DI. 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 17 Service unit combinations LFR-KC/LFRS-KC, D series, metal design Technical data combination LFR-KC/LFRS-KC Operating and environmental conditions Condensate drain Manual rotary Operating pressure Operating medium [bar] Ambient temperature [°C] Temperature of medium [°C] Corrosion resistance class CRC1) Certification 1) Fully automatic 1 … 16 2 … 12 Compressed air in accordance with ISO 8573­1:2010 [–:–:–] Inert gases –10 … +60 –10 … +60 2 Germanischer Lloyd Corrosion resistance class CRC 2 to Festo standard FN 940070 Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo­ sphere typical for industrial applications. Weight [g] Size Mini Midi Maxi LFR LFRS 700 1,000 1,600 1,840 2,300 (2,600)1) 2,400 1) For the LFR-…-D-DI. -H- Note Materials è Technical data of the individual devices p2 [bar] Standard flow rate qn as a function of the output pressure p2 LFR-½-D-DI-MAXI-KC(-A) qn [l/min] Primary pressure p1 = 10 bar 18 è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 Service unit combinations LFR-KC/LFRS-KC, D series, metal design Technical data combination LFR-KC/LFRS-KC Download CAD data è www.festo.com Dimensions LFR/LFRS-…-KC lockable 3 Installation dimensions Type Mini LFR-…-D-MINI-KC (A) LFRS-…-D-MINI-KC (A) Midi LFR-…-D-MIDI-KC (A) LFRS-…-D-MIDI-KC (A) Maxi LFR-…-D-MAXI-KC (A) LFRS-…-D-MAXI-KC (A) LFR-…-D-DI-MAXI-KC (A) è Flow direction B5 B6 D1 H1 H2 H3 L1 L3 L4 L6 L7 L9 L10 T1 T2 104 92 4.3 43 17.5 17.5 193 60 68 98 60 19 3 39 95 140 125 5.3 70 24.5 35.5 250 80 99 130 60 19 3 47 114 162 146 5.3 70 24.5 35.5 82 111 60 19 3 53 126 105 135 252 275 90 -H- Note: This product conforms to ISO 1179-1 and to ISO 228-1 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 19 Service unit combinations LFR-KC/LFRS-KC, D series, metal design Technical data combination LFR-KC/LFRS-KC Ordering data Rotary knob with detent, pressure gauge with outer scale in bar and inner scale in psi Size Connection Condensate drain turned manually Part No. Type Mini Gx G¼ G¼ Gy G½ G½ G¾ 185732 185734 185736 185738 185740 186044 185742 LFR-x-D-MINI-KC-A LFR-¼-D-MINI-KC-A LFR-¼-D-MIDI-KC-A LFR-y-D-MIDI-KC-A LFR-½-D-MIDI-KC-A LFR-½-D-MAXI-KC-A LFR-¾-D-MAXI-KC-A Directly actuated pressure regulator with integrated return flow function Maxi G½ 192442 LFR-½-D-DI-MAXI-KC G¾ 192449 LFR-¾-D-DI-MAXI-KC 192456 192463 LFR-½-D-DI-MAXI-KC-A LFR-¾-D-DI-MAXI-KC-A Ordering data Rotary knob with integrated lock, pressure gauge with outer scale in bar and inner scale in psi Size Connection Condensate drain turned manually Part No. Type Condensate drain fully automatic Part No. Type Midi Maxi Mini Midi Maxi 20 Gx G¼ G¼ Gy G½ G½ G¾ 185731 185733 185735 185737 185739 186043 185741 195012 195026 195040 195054 195068 195082 195096 LFR-x-D-MINI-KC LFR-¼-D-MINI-KC LFR-¼-D-MIDI-KC LFR-y-D-MIDI-KC LFR-½-D-MIDI-KC LFR-½-D-MAXI-KC LFR-¾-D-MAXI-KC Condensate drain fully automatic Part No. Type LFRS-x-D-MINI-KC LFRS-¼-D-MINI-KC LFRS-¼-D-MIDI-KC LFRS-y-D-MIDI-KC LFRS-½-D-MIDI-KC LFRS-½-D-MAXI-KC LFRS-¾-D-MAXI-KC è Internet: www.festo.com/catalogue/... 195013 195027 195041 195055 195069 195083 195097 LFRS-x-D-MINI-KC-A LFRS-¼-D-MINI-KC-A LFRS-¼-D-MIDI-KC-A LFRS-y-D-MIDI-KC-A LFRS-½-D-MIDI-KC-A LFRS-½-D-MAXI-KC-A LFRS-¾-D-MAXI-KC-A Subject to change – 2015/04 Service unit combinations LFR-KD/LFRS-KD, D series, metal design Technical data combination LFR-KD/LFRS-KD -M- LFR/LFRS-…-MINI/MIDI-KD With condensate drain manual rotary -Q-L- Flow rate 595 … 5,000 l/min Temperature range –10 … +60 °C Operating pressure 3 … 16 bar LFR/LFRS-…-MAXI-KD With condensate drain manual rotary For unlubricated compressed air When operating pressure is closed, quick venting ensures rapid pressure reduction Filter regulator LFR/LFRS On-off valve HEE solenoid actuated, 24 V DC Soft-start valve HEL pneumatically actuated Mounting accessories General technical data Size Pneumatic connection 1, 2 Type of mounting Assembly position Grade of filtration Air purity class at the output Bowl guard Condensate drain Actuator lock Pressure regulation range Max. hysteresis Pressure indication Max. condensate volume Mini Midi Gradual pressure build-up prevents sudden, unpredictable movements New filter cartridges è 48 Maxi Gx G¼ G¼ Gy G½ G½ G¾ Via accessories In-line installation Vertical ±5° [μm] 40 Compressed air in accordance with ISO 8573­1:2010 [7:8:4] (Compressed air in accordance with ISO 8573­1:2010 [6:8:4])1) Inert gases Metal bowl guard Manual rotary Fully automatic Rotary knob with detent Rotary knob with integrated lock [bar] 2.5 … 12 [bar] 0.15 0.15 0.25 0.25 0.25 0.3 0.2 Via pressure gauge [cm3] 22 43 80 (43)1) 1) For the LFR-…-D-DI. -H- Note: This product conforms to ISO 1179-1 and to ISO 228-1 Standard nominal flow rate qnN1) [l/min] Connection Mini Gx G¼ Midi G¼ Gy G½ Maxi G½ G¾ In main flow direction 1 > 2 730 1,440 1,890 2,000 4,300 (3,000)2) 5,000 (2,800)2) 1) 2) 595 Measured at p1 = 10 bar, p2 = 6 bar and Δp = 1 bar. For the LFR-…-D-DI. 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 21 Service unit combinations LFR-KD/LFRS-KD, D series, metal design Technical data combination LFR-KD/LFRS-KD Operating and environmental conditions Condensate drain Manual rotary Operating pressure Operating medium [bar] Ambient temperature [°C] Temperature of medium [°C] Corrosion resistance class CRC1) Certification 1) Fully automatic 3 … 16 3 … 12 Compressed air in accordance with ISO 8573­1:2010 [–:–:–] Inert gases –10 … +60 –10 … +60 2 Germanischer Lloyd Corrosion resistance class CRC 2 to Festo standard FN 940070 Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo­ sphere typical for industrial applications. Weight [g] Size Mini Midi Maxi LFR LFRS 900 1,000 2,100 2,340 3,100 (3,300)1) 3,200 1) For the LFR-…-D-DI. -H- Note Materials è Technical data of the individual devices p2 [bar] Standard flow rate qn as a function of the output pressure p2 LFR-½-D-DI-MAXI-KD(-A) qn [l/min] Primary pressure p1 = 10 bar 22 è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 Service unit combinations LFR-KD/LFRS-KD, D series, metal design Technical data combination LFR-KD/LFRS-KD Download CAD data è www.festo.com Dimensions LFR/LFRS-…-KD lockable 3 Installation dimensions Type Mini LFR-…-D-MINI-KD (A) LFRS-…-D-MINI-KD (A) Midi LFR-…-D-MIDI-KD (A) LFRS-…-D-MIDI-KD (A) Maxi LFR-…-D-MAXI-KD (A) LFRS-…-D-MAXI-KD (A) LFR-…-D-DI-MAXI-KD (A) è Flow direction B7 B8 D1 H1 H2 144 132 4.3 43 195 180 5.3 228 212 5.3 H3 L1 L2 L3 L4 L6 L7 L9 L10 T1 T2 T4 T5 17.5 17.5 193 36 60 68 98 60 19 3 39 95 78 15 70 24.5 35.5 250 49.5 80 99 130 60 19 3 47 114 86 15 70 24.5 35.5 82 111 60 19 3 53 126 92 15 105 135 252 275 56.4 90 -H- Note: This product conforms to ISO 1179-1 and to ISO 228-1 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 23 Service unit combinations LFR-KD/LFRS-KD, D series, metal design Technical data combination LFR-KD/LFRS-KD Ordering data Rotary knob with detent, pressure gauge with outer scale in bar and inner scale in psi Size Connection Condensate drain turned manually Part No. Type Mini Gx G¼ G¼ Gy G½ G½ G¾ 185744 185746 185748 185750 185752 186046 185754 LFR-x-D-MINI-KD-A LFR-¼-D-MINI-KD-A LFR-¼-D-MIDI-KD-A LFR-y-D-MIDI-KD-A LFR-½-D-MIDI-KD-A LFR-½-D-MAXI-KD-A LFR-¾-D-MAXI-KD-A Directly actuated pressure regulator with integrated return flow function Maxi G½ 192443 LFR-½-D-DI-MAXI-KD G¾ 192450 LFR-¾-D-DI-MAXI-KD 192457 192464 LFR-½-D-DI-MAXI-KD-A LFR-¾-D-DI-MAXI-KD-A Ordering data Rotary knob with integrated lock, pressure gauge with outer scale in bar and inner scale in psi Size Connection Condensate drain turned manually Part No. Type Condensate drain fully automatic Part No. Type Midi Maxi Mini Midi Maxi 24 Gx G¼ G¼ Gy G½ G½ G¾ 185743 185745 185747 185749 185751 186045 185753 195014 195028 195042 195056 195070 195084 195098 LFR-x-D-MINI-KD LFR-¼-D-MINI-KD LFR-¼-D-MIDI-KD LFR-y-D-MIDI-KD LFR-½-D-MIDI-KD LFR-½-D-MAXI-KD LFR-¾-D-MAXI-KD Condensate drain fully automatic Part No. Type LFRS-x-D-MINI-KD LFRS-¼-D-MINI-KD LFRS-¼-D-MIDI-KD LFRS-y-D-MIDI-KD LFRS-½-D-MIDI-KD LFRS-½-D-MAXI-KD LFRS-¾-D-MAXI-KD è Internet: www.festo.com/catalogue/... 195015 195029 195043 195057 195071 195085 195099 LFRS-x-D-MINI-KD-A LFRS-¼-D-MINI-KD-A LFRS-¼-D-MIDI-KD-A LFRS-y-D-MIDI-KD-A LFRS-½-D-MIDI-KD-A LFRS-½-D-MAXI-KD-A LFRS-¾-D-MAXI-KD-A Subject to change – 2015/04 Service unit combinations LFR-KE/LFRS-KE, D series, metal design Technical data combination LFR-KE/LFRS-KE LFR/LFRS-…-MINI/MIDI-KE With condensate drain manual rotary -M-Q-L- Flow rate 720 … 9,400 l/min Temperature range –10 … +60 °C Operating pressure 1 … 16 bar LFR/LFRS-…-MAXI-KE With condensate drain manual rotary For unlubricated compressed air Filter regulator LFR/LFRS Branching module FRM with pressure switch Mounting accessories General technical data Size Pneumatic connection 1, 2 Type of mounting Assembly position Grade of filtration Air purity class at the output Bowl guard Condensate drain Actuator lock Pressure regulation range Max. hysteresis Pressure indication Max. condensate volume Mini Midi Two branch connections are available Electrical pressure monitoring with adjustable switching pressure New filter cartridges è 48 Maxi Gx G¼ G¼ Gy G½ G½ G¾ Via accessories In-line installation Vertical ±5° [μm] 40 Compressed air in accordance with ISO 8573­1:2010 [7:8:4] (Compressed air in accordance with ISO 8573­1:2010 [6:8:4])1) Inert gases Metal bowl guard Manual rotary Fully automatic Rotary knob with detent Rotary knob with integrated lock [bar] 0.5 … 12 [bar] 0.15 0.15 0.25 0.2 0.2 0.2 0.3 Via pressure gauge [cm3] 22 43 80 (43)1) 1) For the LFR-…-D-DI. -H- Note: This product conforms to ISO 1179-1 and to ISO 228-1 Standard nominal flow rate qnN1) [l/min] Connection Mini Gx In main flow direction 1 > 2 1) 2) 720 G¼ 1,140 Midi G¼ 1,850 Gy 2,620 G½ Maxi G½ G¾ 3,050 9,200 (5,000)2) 9,400 (6,000)2) Measured at p1 = 10 bar, p2 = 6 bar and Δp = 1 bar. For the LFR-…-D-DI. 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 25 Service unit combinations LFR-KE/LFRS-KE, D series, metal design Technical data combination LFR-KE/LFRS-KE Operating and environmental conditions Condensate drain Manual rotary Operating pressure Operating medium [bar] Ambient temperature [°C] Temperature of medium [°C] Corrosion resistance class CRC1) Certification 1) Fully automatic 1 … 16 2 … 12 Compressed air in accordance with ISO 8573­1:2010 [–:–:–] Inert gases –10 … +60 –10 … +60 2 Germanischer Lloyd Corrosion resistance class CRC 2 to Festo standard FN 940070 Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo­ sphere typical for industrial applications. Weight [g] Size Mini Midi Maxi LFR LFRS 1,000 1,100 2,000 2,240 2,400 (2,600)1) 2,500 1) For the LFR-…-D-DI. -H- Note Materials è Technical data of the individual devices p2 [bar] Standard flow rate qn as a function of the output pressure p2 LFR-½-D-DI-MAXI-KE(-A) qn [l/min] Primary pressure p1 = 10 bar 26 è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 Service unit combinations LFR-KE/LFRS-KE, D series, metal design Technical data combination LFR-KE/LFRS-KE Download CAD data è www.festo.com Dimensions LFR/LFRS-…-KE lockable 3 Installation dimensions Type Mini LFR-…-D-MINI-KE (A) LFRS-…-D-MINI-KE (A) Midi LFR-…-D-MIDI-KE (A) LFRS-…-D-MIDI-KE (A) Maxi LFR-…-D-MAXI-KE (A) LFRS-…-D-MAXI-KE (A) LFR-…-D-DI-MAXI-KE (A) è Flow direction B5 B6 D1 H1 H2 104 92 4.3 43 140 125 5.3 162 146 5.3 H3 L1 L2 L3 L4 L6 L7 L9 L10 T1 T2 T3 T5 17.5 17.5 193 108 60 68 98 60 19 3 39 95 97 15 70 24.5 35.5 250 117 80 99 130 60 19 3 47 114 109 15 70 24.5 35.5 122 90 82 111 60 19 3 53 126 111 15 105 135 252 275 -H- Note: This product conforms to ISO 1179-1 and to ISO 228-1 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 27 Service unit combinations LFR-KE/LFRS-KE, D series, metal design Technical data combination LFR-KE/LFRS-KE Ordering data Rotary knob with detent, pressure gauge with outer scale in bar and inner scale in psi Size Connection Condensate drain turned manually Part No. Type Mini Gx G¼ G¼ Gy G½ G½ G¾ 185756 185758 185760 185762 185764 186048 185766 LFR-x-D-MINI-KE-A LFR-¼-D-MINI-KE-A LFR-¼-D-MIDI-KE-A LFR-y-D-MIDI-KE-A LFR-½-D-MIDI-KE-A LFR-½-D-MAXI-KE-A LFR-¾-D-MAXI-KE-A Directly actuated pressure regulator with integrated return flow function Maxi G½ 192444 LFR-½-D-DI-MAXI-KE G¾ 192451 LFR-¾-D-DI-MAXI-KE 192458 192465 LFR-½-D-DI-MAXI-KE-A LFR-¾-D-DI-MAXI-KE-A Ordering data Rotary knob with integrated lock, pressure gauge with outer scale in bar and inner scale in psi Size Connection Condensate drain turned manually Part No. Type Condensate drain fully automatic Part No. Type Midi Maxi Mini Midi Maxi 28 Gx G¼ G¼ Gy G½ G½ G¾ 185755 185757 185759 185761 185763 186047 185765 195016 195030 195044 195058 195072 195086 195100 LFR-x-D-MINI-KE LFR-¼-D-MINI-KE LFR-¼-D-MIDI-KE LFR-y-D-MIDI-KE LFR-½-D-MIDI-KE LFR-½-D-MAXI-KE LFR-¾-D-MAXI-KE Condensate drain fully automatic Part No. Type LFRS-x-D-MINI-KE LFRS-¼-D-MINI-KE LFRS-¼-D-MIDI-KE LFRS-y-D-MIDI-KE LFRS-½-D-MIDI-KE LFRS-½-D-MAXI-KE LFRS-¾-D-MAXI-KE è Internet: www.festo.com/catalogue/... 195017 195031 195045 195059 195073 195087 195101 LFRS-x-D-MINI-KE-A LFRS-¼-D-MINI-KE-A LFRS-¼-D-MIDI-KE-A LFRS-y-D-MIDI-KE-A LFRS-½-D-MIDI-KE-A LFRS-½-D-MAXI-KE-A LFRS-¾-D-MAXI-KE-A Subject to change – 2015/04 Service unit combinations LFR-KF/LFRS-KF, D series, metal design Technical data combination LFR-KF/LFRS-KF -M- LFR/LFRS-…-MINI/MIDI-KF With condensate drain manual rotary -Q-L- Flow rate 700 … 8,400 l/min Temperature range –10 … +60 °C Operating pressure 1 … 16 bar LFR/LFRS-…-MAXI-KF With condensate drain manual rotary For unlubricated compressed air Operating pressure can be opened and closed Two branch connections are available On-off valve HE manually actuated Filter regulator LFR/LFRS Branching module FRM with pressure switch Mounting accessories General technical data Size Pneumatic connection 1, 2 Type of mounting Assembly position Grade of filtration Air purity class at the output Bowl guard Condensate drain Actuator lock Pressure regulation range Max. hysteresis Pressure indication Max. condensate volume Mini Midi Electrical pressure monitoring with adjustable switching pressure To ensure safe venting of the sys­ tem, an additional quick exhaust valve is necessary at the output of the service unit combination New filter cartridges è 48 Maxi Gx G¼ G¼ Gy G½ G½ G¾ Via accessories In-line installation Vertical ±5° [μm] 40 Compressed air in accordance with ISO 8573­1:2010 [7:8:4] (Compressed air in accordance with ISO 8573­1:2010 [6:8:4])1) Inert gases Metal bowl guard Manual rotary Fully automatic Rotary knob with detent Rotary knob with integrated lock [bar] 0.5 … 12 [bar] 0.2 0.2 0.25 0.3 0.25 0.2 0.2 Via pressure gauge [cm3] 22 43 80 (43)1) 1) For the LFR-…-D-DI. -H- Note: This product conforms to ISO 1179-1 and to ISO 228-1 Standard nominal flow rate qnN1) [l/min] Connection Mini Gx G¼ Midi G¼ Gy G½ Maxi G½ G¾ In main flow direction 1 > 2 1,050 1,720 2,420 2,920 8,000 (5,000)2) 8,400 (6,000)2) 1) 2) 700 Measured at p1 = 10 bar, p2 = 6 bar and Δp = 1 bar. For the LFR-…-D-DI. 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 29 Service unit combinations LFR-KF/LFRS-KF, D series, metal design Technical data combination LFR-KF/LFRS-KF Operating and environmental conditions Condensate drain Manual rotary Operating pressure Operating medium [bar] Ambient temperature [°C] Temperature of medium [°C] Corrosion resistance class CRC1) Certification 1) Fully automatic 1 … 16 2 … 12 Compressed air in accordance with ISO 8573­1:2010 [–:–:–] Inert gases –10 … +60 –10 … +60 2 Germanischer Lloyd Corrosion resistance class 2 according to Festo standard 940 070 Components subject to moderate corrosion stress. Externally visible parts with primarily decorative surface requirements which are in direct contact with a normal industrial environment or media such as coolants or lubricating agents. Weight [g] Size Mini Midi Maxi LFR LFRS 1,200 1,300 2,400 2,640 3,300 (3,500)1) 3,400 1) For the LFR-…-D-DI. -H- Note Materials è Technical data of the individual devices p2 [bar] Standard flow rate qn as a function of the output pressure p2 LFR-½-D-DI-MAXI-KF(-A) qn [l/min] Primary pressure p1 = 10 bar 30 è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 Service unit combinations LFR-KF/LFRS-KF, D series, metal design Technical data combination LFR-KF/LFRS-KF Download CAD data è www.festo.com Dimensions LFR/LFRS-…-KF lockable 3 Installation dimensions Type Mini LFR-…-D-MINI-KF (A) LFRS-…-D-MINI-KF (A) Midi LFR-…-D-MIDI-KF (A) LFRS-…-D-MIDI-KF (A) Maxi LFR-…-D-MAXI-KF (A) LFRS-…-D-MAXI-KF (A) LFR-…-D-DI-MAXI-KF (A) è Flow direction B7 B8 D1 H1 H2 144 132 4.3 43 195 180 5.3 228 212 5.3 H3 L1 L2 L3 L4 L6 L7 L9 L10 T1 T2 T3 T5 17.5 17.5 193 108 60 68 98 60 19 3 39 95 97 15 70 24.5 35.5 250 117 80 99 130 60 19 3 47 114 105 15 70 24.5 35.5 122 90 82 111 60 19 3 53 126 111 15 105 135 252 275 -H- Note: This product conforms to ISO 1179-1 and to ISO 228-1 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 31 Service unit combinations LFR-KF/LFRS-KF, D series, metal design Technical data combination LFR-KF/LFRS-KF Ordering data Rotary knob with detent, pressure gauge with outer scale in bar and inner scale in psi Size Connection Condensate drain turned manually Part No. Type Mini Gx G¼ G¼ Gy G½ G½ G¾ 185768 185770 185772 185774 185776 186050 185778 LFR-x-D-MINI-KF-A LFR-¼-D-MINI-KF-A LFR-¼-D-MIDI-KF-A LFR-y-D-MIDI-KF-A LFR-½-D-MIDI-KF-A LFR-½-D-MAXI-KF-A LFR-¾-D-MAXI-KF-A Directly actuated pressure regulator with integrated return flow function Maxi G½ 192445 LFR-½-D-DI-MAXI-KF G¾ 192452 LFR-¾-D-DI-MAXI-KF 192459 192466 LFR-½-D-DI-MAXI-KF-A LFR-¾-D-DI-MAXI-KF-A Ordering data Rotary knob with integrated lock, pressure gauge with outer scale in bar and inner scale in psi Size Connection Condensate drain turned manually Part No. Type Condensate drain fully automatic Part No. Type Midi Maxi Mini Midi Maxi 32 Gx G¼ G¼ Gy G½ G½ G¾ 185767 185769 185771 185773 185775 186049 185777 195018 195032 195046 195060 195074 195088 195102 LFR-x-D-MINI-KF LFR-¼-D-MINI-KF LFR-¼-D-MIDI-KF LFR-y-D-MIDI-KF LFR-½-D-MIDI-KF LFR-½-D-MAXI-KF LFR-¾-D-MAXI-KF Condensate drain fully automatic Part No. Type LFRS-x-D-MINI-KF LFRS-¼-D-MINI-KF LFRS-¼-D-MIDI-KF LFRS-y-D-MIDI-KF LFRS-½-D-MIDI-KF LFRS-½-D-MAXI-KF LFRS-¾-D-MAXI-KF è Internet: www.festo.com/catalogue/... 195019 195033 195047 195061 195075 195089 195103 LFRS-x-D-MINI-KF-A LFRS-¼-D-MINI-KF-A LFRS-¼-D-MIDI-KF-A LFRS-y-D-MIDI-KF-A LFRS-½-D-MIDI-KF-A LFRS-½-D-MAXI-KF-A LFRS-¾-D-MAXI-KF-A Subject to change – 2015/04 Service unit combinations LFR-KG/LFRS-KG, D series, metal design Technical data combination LFR-KG/LFRS-KG -M- LFR/LFRS-…-MINI/MIDI-KG With condensate drain manual rotary -Q-L- Flow rate 575 … 4,900 l/min Temperature range –10 … +60 °C Operating pressure 3 … 16 bar LFR/LFRS-…-MAXI-KG With condensate drain manual rotary For unlubricated compressed air To ensure safe venting of the sys­ tem, an additional quick exhaust valve is necessary at the output of the service unit combination On-off valve HE manually actuated Filter regulator LFR/LFRS On-off valve HEE solenoid actuated, 24 V DC Soft-start valve HEL pneumatically actuated Branching module FRM with pressure switch Mounting accessories General technical data Size Pneumatic connection 1, 2 Type of mounting Assembly position Grade of filtration Air purity class at the output Bowl guard Condensate drain Actuator lock Pressure regulation range Max. hysteresis Pressure indication Max. condensate volume Mini Midi Two branch connections are available Gradual pressure build-up prevents sudden, unpredictable movements Electrical pressure monitoring with adjustable switching pressure New filter cartridges è 48 Maxi Gx G¼ G¼ Gy G½ G½ G¾ Via accessories In-line installation Vertical ±5° [μm] 40 Compressed air in accordance with ISO 8573­1:2010 [7:8:4] (Compressed air in accordance with ISO 8573­1:2010 [6:8:4])1) Inert gases Metal bowl guard Manual rotary Fully automatic Rotary knob with detent Rotary knob with integrated lock [bar] 2.5 … 12 [bar] 0.15 0.15 0.25 0.2 0.2 0.25 0.25 Via pressure gauge [cm3] 22 43 80 (43)1) 1) For the LFR-…-D-DI. -H- Note: This product conforms to ISO 1179-1 and to ISO 228-1 Standard nominal flow rate qnN1) [l/min] Connection Mini Gx In main flow direction 1 > 2 1) 2) 575 G¼ 715 Midi G¼ 1,370 Gy 1,680 G½ Maxi G½ G¾ 1,740 4,200 (2,500)2) 4,900 (3,000)2) Measured at p1 = 10 bar, p2 = 6 bar and Δp = 1 bar. For the LFR-…-D-DI. 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 33 Service unit combinations LFR-KG/LFRS-KG, D series, metal design Technical data LFR-KG/LFRS-KG Operating and environmental conditions Condensate drain Manual rotary Operating pressure Operating medium [bar] Ambient temperature [°C] Temperature of medium [°C] Corrosion resistance class CRC1) Certification 1) Fully automatic 3 … 16 3 … 12 Compressed air in accordance with ISO 8573­1:2010 [–:–:–] Inert gases –10 … +60 –10 … +60 2 Germanischer Lloyd Corrosion resistance class CRC 2 to Festo standard FN 940070 Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo­ sphere typical for industrial applications. Weight [g] Size Mini Midi Maxi LFR LFRS 1,500 1,600 3,400 3,640 5,200 (5,400)1) 5,300 1) For the LFR-…-D-DI. -H- Note Materials è Technical data of the individual devices p2 [bar] Standard flow rate qn as a function of the output pressure p2 LFR-½-D-DI-MAXI-KG(-A) qn [l/min] Primary pressure p1 = 10 bar 34 è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 Service unit combinations LFR-KG/LFRS-KG, D series, metal design Technical data LFR-KG/LFRS-KG Download CAD data è www.festo.com Dimensions LFR/LFRS-…-KG lockable 3 Installation dimensions Type Mini LFR-…-D-MINI-KG (A) LFRS-…-D-MINI-KG (A) Midi LFR-…-D-MIDI-KG (A) LFRS-…-D-MIDI-KG (A) Maxi LFR-…-D-MAXI-KG (A) LFRS-…-D-MAXI-KG (A) LFR-…-D-DI-MAXI-KG (A) è Flow direction B9 B10 D1 H1 H2 H3 L1 L3 L4 L6 L7 L9 L10 T1 T2 T3 T4 T5 224 212 4.3 43 17.5 17.5 193 108 60 68 98 60 19 3 39 95 97 78 15 305 290 5.3 70 24.5 35.5 250 117 80 99 130 60 19 3 47 114 105 86 15 360 344 5.3 70 24.5 35.5 82 111 19 3 53 126 111 92 15 252 275 L2 122 90 60 105 135 -H- Note: This product conforms to ISO 1179-1 and to ISO 228-1 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 35 Service unit combinations LFR-KG/LFRS-KG, D series, metal design Technical data LFR-KG/LFRS-KG Ordering data Rotary knob with detent, pressure gauge with outer scale in bar and inner scale in psi Size Connection Condensate drain turned manually Part No. Type Mini Gx G¼ G¼ Gy G½ G½ G¾ 185780 185782 185784 185786 185788 186052 185790 LFR-x-D-MINI-KG-A LFR-¼-D-MINI-KG-A LFR-¼-D-MIDI-KG-A LFR-y-D-MIDI-KG-A LFR-½-D-MIDI-KG-A LFR-½-D-MAXI-KG-A LFR-¾-D-MAXI-KG-A Directly actuated pressure regulator with integrated return flow function Maxi G½ 192446 LFR-½-D-DI-MAXI-KG G¾ 192453 LFR-¾-D-DI-MAXI-KG 192460 192467 LFR-½-D-DI-MAXI-KG-A LFR-¾-D-DI-MAXI-KG-A Ordering data Rotary knob with integrated lock, pressure gauge with outer scale in bar and inner scale in psi Size Connection Condensate drain turned manually Part No. Type Condensate drain fully automatic Part No. Type Midi Maxi Mini Midi Maxi 36 Gx G¼ G¼ Gy G½ G½ G¾ 185779 185781 185783 185785 185787 186051 185789 195020 195034 195048 195062 195076 195090 195104 LFR-x-D-MINI-KG LFR-¼-D-MINI-KG LFR-¼-D-MIDI-KG LFR-y-D-MIDI-KG LFR-½-D-MIDI-KG LFR-½-D-MAXI-KG LFR-¾-D-MAXI-KG Condensate drain fully automatic Part No. Type LFRS-x-D-MINI-KG LFRS-¼-D-MINI-KG LFRS-¼-D-MIDI-KG LFRS-y-D-MIDI-KG LFRS-½-D-MIDI-KG LFRS-½-D-MAXI-KG LFRS-¾-D-MAXI-KG è Internet: www.festo.com/catalogue/... 195021 195035 195049 195063 195077 195091 195105 LFRS-x-D-MINI-KG-A LFRS-¼-D-MINI-KG-A LFRS-¼-D-MIDI-KG-A LFRS-y-D-MIDI-KG-A LFRS-½-D-MIDI-KG-A LFRS-½-D-MAXI-KG-A LFRS-¾-D-MAXI-KG-A Subject to change – 2015/04 Service unit combinations LFR-KG/LFRS-KG, D series, metal design Technical data LFR-KG/LFRS-KG 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 37 -V- New Service unit combinations LFR-K, D series, polymer Product range overview D series service units, polymer Type Service units FRC Service unit combinations FRC-K LFR-K Individual devices Filter regulators LFR Size Pressure regulation range [bar] Grade of filtration [μm] Gx G¼ G½ 0.5 … 7 5 40 n n – n n n – n – n – n – n – n – n n n – n n n n n – n – – – – n n – – Mini Mini Mini Mini Pressure regulators LR Mini Pressure regulator combinations LRB-K Mini 38 Pneumatic connection è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 -V- New Service unit combinations LFR-K, D series, polymer Product range overview D series service units, polymer è Page/ Internet With return flow function Regulating functions With secondary venting Rotary knob with detent Actuator lock Without pressure gauge Mini Pressure display With pressure gauge Service units FRC Condensate drain Semi-automatic Size Manual rotary Type frc n n n – n n n Service unit combinations FRC-K Mini frc n LFR-K – n – n n n Mini 40 n Individual devices Filter Mini regulators LFR Pressure regulators LR Mini Pressure regulator combinations LRB-K Mini n – n n n lfr n n n n n n n lr – 2015/04 – Subject to change – – n n n n n lrb – – – n n è Internet: www.festo.com/catalogue/... n n 39 -V- New Service unit combinations LFR-K, D series, polymer Peripherals overview 2 -H- Note The range of accessories depends on the selected service unit combination. The example shows the service unit combination LFR-KB. 1 3 Mounting components and accessories è Page/Internet 1 Mounting bracket hr-d HR-D 2 Hex nut hmr-d 3 HMR Padlock lrvs-d – LRVS Filter cartridge 48 MS4-LFP-E 40 è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 -V- New Service unit combinations LFR-K, D series, polymer Type codes LFR — ¼ — DB — 7 — MINI — KB Basic function LFR Service unit combination Pneumatic connection ¼ Thread G¼ Series DB D series, polymer design Pressure regulation range 7 0.5 … 7 bar Size MINI Options for service unit combinations KB KC Manually operated on-off valve, filter regulator and distributor module Manually operated on-off valve and filter regulator 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 41 -V- New Service unit combinations LFR-KB, D series, polymer Technical data – LFR-KB combination -M- Function 1 -Q- 2 3 -L- Manually operated on-off valve Filter regulator Distributor module Standard nominal flow rate 1,900 l/min Temperature range –5 … +50 °C Operating pressure 1.5 … 10 bar For unlubricated compressed air The operating pressure can be switched on or off General technical data Size Mini Pneumatic connection 1, 2, 3 Design Regulator type Type of mounting Mounting position Grade of filtration Air purity class at the output Condensate drain Actuation security Exhaust function Pressure regulation range Max. pressure hysteresis Pressure indication Pressure gauge connection Max. condensate volume Three connections are available New filter cartridges è 48 G¼ On-off valve/filter regulator/distributor module Output pressure constant, without primary pressure compensation, with return flow action, with secondary venting In-line installation Via through-hole Via mounting bracket Vertical ±5° 40 Compressed air according to ISO 8573-1:2010 [7:8:4] Manual rotary Rotary knob with detent Padlock (optional) No flow control 0.5 … 7 0.5 Via pressure gauge Gx 13 [μm] [bar] [bar] [ml] Flow rates [l/min] Standard nominal flow rate qnN1) Max. standard flow rate 1) Measured at p1 = 10 bar, p2 = 6 bar and Δp = 1 bar. -H- Note The design allows for slight leakage at the outlet. It improves the control response of the controller without 42 1,900 2,500 input pressure compensation. In rare cases, however, the leakage can sporadically be up to 500 l/h. è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 -V- New Service unit combinations LFR-KB, D series, polymer Technical data – LFR-KB combination Operating and environmental conditions Operating pressure [bar] Operating medium Note on operating/pilot medium Ambient temperature [°C] Temperature of medium [°C] Storage temperature [°C] Corrosion resistance class CRC1) 1) 1.5 … 10 Compressed air according to ISO 8573-1:2010 [7:9:4] Lubricated operation not possible –5 … +50 –5 … +50 –5 … +50 1 Corrosion resistance class CRC 1 to Festo standard FN 940070 Low corrosion stress. For dry indoor applications or transport and storage protection. Also applies to parts behind covers, in the non-visible interior area, and parts which are covered in the application (e.g. drive trunnions). Weight [g] Service unit 270 Materials Housing Piston spool Bowl Rotary knob Filter Seals On-off valve seals Note on materials PA reinforced POM PC POM PE NBR FPM RoHS-compliant Standard flow rate qn as a function of the output pressure p2 LFR-¼-DB-7-MINI-KB Input pressure p1 = 10 bar 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 43 -V- New Service unit combinations LFR-KB, D series, polymer Technical data – LFR-KB combination Download CAD data è www.festo.com Dimensions Mini 1 Barbed connector for plastic tubing PCN-4 2 Installation dimensions 4 M4 socket head screw for wall mounting (2 included in the scope of delivery) 5 Recommended through-holes for wall mounting via socket head screws è Flow direction Type D1 B1 B2 B3 B4 B5 B6 B7 D2 D3 D4 D5 D6 LFR-¼-DB G¼ 108 78 47 78 44 34 5 32 M4 M36x1.5 39 5 Type H1 H2 H3 L1 L3 min. L4 L6 L7 L8 L9 L10 T1 ß1 LFR-¼-DB 40 20 10 189 60 113 66 42 17 11 2 9 14 Ordering data Condensate drain Size Connection Grade of filtration 40 μm Part No. Type Pressure gauge with outer scale in bar and inner scale in psi Manual rotary Mini G¼ 8002798 LFR-¼-DB-7-MINI-KB 44 è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 -V- New Service unit combinations LFR-KC, D series, polymer Technical data – LFR-KC combination -M- Function -Q-L Manually operated on-off valve Filter regulator Standard nominal flow rate 1,900 l/min Temperature range –5 … +50 °C Operating pressure 1.5 … 10 bar For unlubricated compressed air The operating pressure can be switched on or off General technical data Size Mini Pneumatic connection 1, 2 Design Regulator type Type of mounting Mounting position Grade of filtration Air purity class at the output Condensate drain Actuation security Exhaust function Pressure regulation range Max. pressure hysteresis Pressure indication Pressure gauge connection Max. condensate volume New filter cartridges è 48 G¼ On-off valve/filter regulator Output pressure constant, without primary pressure compensation, with return flow action, with secondary venting In-line installation Via through-hole Via mounting bracket Vertical ±5° 40 Compressed air according to ISO 8573-1:2010 [7:8:4] Manual rotary Rotary knob with detent Padlock (optional) No flow control 0.5 … 7 0.5 Via pressure gauge Gx 13 [μm] [bar] [bar] [ml] Flow rates [l/min] Standard nominal flow rate qnN1) Max. standard flow rate 1) 1,900 2,500 Measured at p1 = 10 bar, p2 = 6 bar and Δp = 1 bar. -H- Note The design allows for slight leakage at the outlet. It improves the control response of the controller without 2015/04 – Subject to change input pressure compensation. In rare cases, however, the leakage can sporadically be up to 500 l/h. è Internet: www.festo.com/catalogue/... 45 -V- New Service unit combinations LFR-KC, D series, polymer Technical data – LFR-KC combination Operating and environmental conditions Operating pressure [bar] Operating medium Note on operating/pilot medium Ambient temperature [°C] Temperature of medium [°C] Storage temperature [°C] Corrosion resistance class CRC1) 1) 1.5 … 10 Compressed air according to ISO 8573-1:2010 [7:9:4] Lubricated operation not possible –5 … +50 –5 … +50 –5 … +50 1 Corrosion resistance class CRC 1 to Festo standard FN 940070 Low corrosion stress. For dry indoor applications or transport and storage protection. Also applies to parts behind covers, in the non-visible interior area, and parts which are covered in the application (e.g. drive trunnions). Weight [g] Service unit 245 Materials Housing Piston spool Bowl Rotary knob Filter Seals On-off valve seals Note on materials PA reinforced POM PC POM PE NBR FPM RoHS-compliant Standard flow rate qn as a function of the output pressure p2 LFR-¼-DB-7-MINI-KC Input pressure p1 = 10 bar 46 è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 -V- New Service unit combinations LFR-KC, D series, polymer Technical data – LFR-KC combination Download CAD data è www.festo.com Dimensions Mini 1 Barbed connector for plastic tubing PCN-4 2 Installation dimensions 4 M4 socket head screw for wall mounting (2 included in the scope of delivery) 5 Recommended through-holes for wall mounting via socket head screws è Flow direction Type D1 B1 B2 B3 B4 B5 B6 B7 D2 D3 D4 D5 D6 LFR-¼-DB G¼ 88 78 47 78 44 34 5 32 M4 M36x1.5 39 5 Type H1 H2 H3 L1 L3 min. L4 L6 L7 L8 L9 L10 T1 ß1 LFR-¼-DB 40 20 10 189 60 113 66 42 17 11 2 9 14 Ordering data Condensate drain Size Connection Grade of filtration 40 μm Part No. Type Pressure gauge with outer scale in bar and inner scale in psi Manual rotary Mini G¼ 8002799 LFR-¼-DB-7-MINI-KC 2015/04 – Subject to change è Internet: www.festo.com/catalogue/... 47 Service unit combinations LFR-K/LFRS-K, D series Accessories Filter cartridges, D series, metal design Ordering data Size Grade of filtration [μm] Part No. Type Mini Midi Maxi 363665 363667 363664 LFP-D-MINI-40M LFP-D-MIDI-40M LFP-D-MAXI-40M Ordering data Size Grade of filtration [μm] Part No. Type Mini 534502 MS4-LFP-E 40 (colour: white) 40 (colour: white) 40 (colour: white) Filter cartridges, D series, polymer 48 40 è Internet: www.festo.com/catalogue/... Subject to change – 2015/04 Service unit combinations LFR-K/LFRS-K, D series Accessories Ordering data – Angled socket PEV Description for PEV-¼-…-OD Ordering data – Plug socket MSSD Description for PEV-¼-…-OD for on-off valve HEE Operating voltage range Electrical connection Technical data è Internet: pev-1/4 Switching status display Part No. Type 15 …. 30 V DC 4-pin Yellow LED 164274 PEV-¼-WD-LED-24 230 V AC 180 V DC 4-pin Yellow LED 164275 PEV-¼-WD-LED-230 Operating voltage range Electrical connection Type of mounting cable connection 250 V AC/DC 250 V AC/DC 3-pin 3-pin 4-pin Clamping screws 171157 Clamping screws 151687 Insulation displacement 192745 technology Ordering data – Plug socket with cable KMEB Description Operating voltage Electrical range connection for on-off valve HEE Cable length [m] 2.5 5 10 2.5 5 24 V DC 3-pin LED 230 V AC 3-pin – Ordering data – Illuminating seal MEB-LD Description for plug socket with cable KMEB and plug socket MSSD-EB 2015/04 – Subject to change Switching status display Technical data è Internet: mssd Part No. Type MSSD-C-4P MSSD-EB MSSD-EB-S-M14 Technical data è Internet: kmeb Part No. Type 151688 151689 193457 151690 151691 KMEB-1-24-2,5-LED KMEB-1-24-5-LED KMEB-1-24-10-LED KMEB-1-230AC-2,5 KMEB-1-230AC-5 Part No. 12 … 24 V DC 230 V DC/AC ±10% 151717 151718 Technical data è Internet: meb Type Operating voltage range è Internet: www.festo.com/catalogue/... MEB-LD-12-24DC MEB-LD-230AC 49