Pergola Fixing

advertisement
E N GI NE E RED
B UILD ING
PR OD UC TS
PergolaFixing
Pe
r g o l a
Fi
x i n g
THE SIMPLE WAY TO SECURE
PERGOLAS TO FASCIAS
APPLICATION:
MiTek Joist Hangers provide a quick and efficient
method to fix timber pergolas to existing timber or steel
fascia boards.
USES
SPECIFICATIONS:
• Joist Hangers provide a simple
but effective method of securing
timber pergola beams to
existing timber fascia boards.
Steel Grade
G300
Thickness
(Total Coated)
• See over for use with metal
fascia.
1.0mm
Galvanized
Coating
ADVANTAGES
• Joist Hangers are suitable for
a variety of fascia styles.
Nails
• Fixing methods can be easily
achieved for different fascia
styles without the need to
remove gutter or disturb
existing fascia details.
Z275
MiTek 30 x 2.8mm
galvanized
reinforced head.
Product Code
This Engineered Building Product complies with the
National Construction Code Series and Australian Standards.
2
See Table
Pe
r g o l a
Fi
- In
x i n g
s ta l l at i o n
Joist Hanger Sizes
Dimensions(mm)
Product Code
Type
A
B
JH4090
40 x 90
41
82
JH40120
40 x 120
41
115
JH40190
40 x 190
41
180
JH5090
50 x 90
51
77
JH50120
50 x 120
51
110
JH50190
50 x 190
51
175
B
A
STEEL FASCIA DETAIL
To fix a pergola to steel fascia, the steel fascia must first be reinforced by installing 150 x 50mm noggings between
rafters. A timber trimmer can then be fixed to steel fascia by coach screwing to noggings.
A Joist Hanger to suit pergola beam thickness and distance between gutter and bottom of trimmer can then be fixed
at pergola beam spacing.
NOTE: Rafter overhang should be checked by an engineer to carry additional weight from pergola beam.
COMMON INSTALLATION
1. Locate the Joist Hanger accurately, then drive five MiTek 30 x 2.8mm galvanized reinforced head nails through all holes in each wing.
2. Place beam into position and drive three 30 x 2.8mm galvanized reinforced head nails through holes in each side of boot.
Roof tiles
Spouting
Scribe ends of beams
around spouting
Rafter
150 x 50mm nogging
fixed between rafters
Timber pergola beam
Joist Hanger for
fascia/beam connection
100 x 50mm trimmer fixed to
nogging using two 100 x 10mm coach
screws at each timber pergola beam.
3
Metal fascia
Eaves lining
Pe
r g o l a
Fi
x i n g
- In
s ta l l at i o n
STANDARD GUTTER DETAIL
CONCEALED GUTTER DETAIL
1.Select a Joist Hanger size to suit timber pergola beam
thickness which will fit between bottom of timber fascia
and underside of gutter.
1. Fasten Joist Hangers to fascia using a string line to achieve a
straight line, placing the bottom of Joist Hanger approximately
25mm above the level of the bottom of pergola beam.
This will allow the bottom of the pergola beam to be trimmed
to sit neatly in the shoe of the Joist Hanger.
2. Fix Joist Hangers so that shoe is level with bottom of fascia.
Standard Gutter
Roof tiles
Spouting
Scribe ends
of beams
around spouting
Rafter
Eaves lining
Timber beam
Concealed Gutter
Roof tiles
Joist Hanger for
fascia/beam connection
Concealed
spouting
Timber fascia
Rafter
Timber beam
Bevel cut beam
to suit fascia
Cut back bottom
of beam to fit into
Joist Hanger
Joist Hanger
(nails must not be longer than
30mm to avoid punching the
concealed spouting)
Eaves lining
Timber fascia
PG 07/15
For more information about MiTek’s Engineered Building Products or any other MiTek products or your nearest
licensed MiTek fabricator, please call your local state office or visit: mitek.com.au
HOME OF GANG-NAIL BUILDING SYSTEMS
VIC (03) 8795 8888
NSW (02) 8525 8000
QLD (07) 3861 2100
SA (08) 8234 1326
WA (08) 9412 3534
New Zealand (09) 274 7109
Download