SSPA Remote Control Panel RCP-2001 Introduction The RCP-2001 allows you to easily monitor and control an Antenna-Mount solid-state power amplifier (SSPA) or other singlemodule SSPA from a remote location. The RCP-2001 enables the remote, real-time operation of a single SSPA, which is especially convenient for installations where the SSPA is located in an inaccessible or inconvenient location. Part Number/Ordering Information Features User-friendly menu structure for SSPA control commands and status display Provides customer Serial I/O port (up to 28.8 kBps) Audible alarm Worldwide AC input capability Can be located up to 1.3 km (4000') from SSPA with inexpensive cable Compatible with all Antenna-Mount SSPAs with firmware version 2.0x or higher RCP-2001 Options 1 3 5 6 Rack Slides Parallel I/O DC Power 24 V DC Power 48 V Order cable ACAB-13135-X separately (where ‘X’ denotes length in feet, in 50 ft increments). Front Panel RCP-2001 ONLINE 1 RF ON MODIFY MENU FAULT FAULT RESET SEL MUTE ONLINE 2 WARNING PREV GAIN Rear Panel SERIAL I/O SSPA LINK AUX OPTION 3 PARALLEL I/O J3 J4 FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE. 85-264 V 47-63 Hz J1 J2 RCP-2001 VX.XX Connector Interface Ref. Des. Function Connector Type Mating Connector Comment J1 AC In IEC 320 IEC Cordset Standard " DC In 4-pin MS, Male 4-pin MS, Female Option 5 or 6 J2 Serial I/O 9-pin D, Female 9-pin D, Male Standard J3 SSPA Link 9-pin D, Male 9-pin D, Female Standard J5 Parallel I/O 37-pin D, Male 37-pin D, Female Option 3 Specifications Parameter Notes Min. Power Requirements Voltage, Standard Frequency Power Voltage, Option 5 Voltage, Option 6 85 47 Operating Temperature Range Nom./Typ. Max. Units 20 42 265 63 13.5 32 56 Vac Hz W Vdc Vdc 0 +50 °C SSPA Link Cable Length 4000 (1.3) Size † † 19 W x 1.72 H x 17.52 D 482.6 x 43.7 x 445 ft (km) inches mm When there is only one value on a line, the Nom./Typ. column is a nominal value; otherwise it is a typical value. Typical values are intended to illustrate typical performance, but are not guaranteed. Parallel I/O (Option 3) The RCP-2001's parallel I/O (Option 3) provides eight independent contact-closure inputs and eight Form 'C' outputs. Each input or output is easily configured via the RCP-2001's front panel display and an extensive menu of SSPA control and status monitoring options. Outputs * Inputs * No function User Fault (Active High) User Fault (Active Low) Mute Un-Mute Mute/Un-Mute Toggle Mute (Low)/Un-Mute (High) RF Inhibit (Active Low) RF Inhibit (Active High) Fault Reset No function (user-defined function) Output Power Fault (High or Low) Voltage Fault Any Fault Remote/Local Mode Maintenance Mode RF Inhibit RF On/Off Mute/Operate Any Warning Any Fault or Warning Temperature Fault Current Fault Ratings Inputs: Contact closure to ground (5 V/5 mA) Outputs: Form 'C' dry contacts 100 V/0.5 A/3 W maximum * Additional functions may be offered for SSPAs with optional hardware features. Other Products • • • • • • • • • Solid-State Power Amplifiers and SSPA Systems Solid-State Power BUCs and SSPB Systems Low Noise Amplifiers and LNA Systems Low Noise Block Converters and LNB Systems Block Up and Block Down Converters Synthesized Converters Line Drive Amplifiers Power Supply Monitors Redundant Control Panels for SSPAs, SSPBs, and LNAs 60 Decibel Road, Suite 200 • State College, PA 16801 USA • Tel. +1-814-238-2700 • FAX +1-814-238-6589 Email: satcom@gd-ms.com • www.gdsatcom.com/electronics.php © 2015 General Dynamics. All rights reserved. General Dynamics reserves the right to make changes to its products and specifications at any time and without notice. All trademarks indicated as such herein are trademarks of General Dynamics. All other product and service names are the property of their respective owners. 12724 Rev. A