SSPA Remote Control Panel - General Dynamics SATCOM

advertisement
SSPA Remote Control Panel
RCP-2001
Introduction
The RCP-2001 allows you to easily monitor and control an Antenna-Mount solid-state power amplifier (SSPA) or other singlemodule SSPA from a remote location. The RCP-2001 enables the remote, real-time operation of a single SSPA, which is
especially convenient for installations where the SSPA is located in an inaccessible or inconvenient location.
Part Number/Ordering Information
Features
User-friendly menu structure for SSPA control commands
and status display
Provides customer Serial I/O port (up to 28.8 kBps)
Audible alarm
Worldwide AC input capability
Can be located up to 1.3 km (4000') from SSPA with
inexpensive cable
Compatible with all Antenna-Mount SSPAs with firmware
version 2.0x or higher
RCP-2001
Options
1
3
5
6
Rack Slides
Parallel I/O
DC Power 24 V
DC Power 48 V
Order cable ACAB-13135-X separately
(where ‘X’ denotes length in feet, in 50 ft
increments).
Front Panel
RCP-2001
ONLINE 1
RF ON
MODIFY
MENU
FAULT
FAULT
RESET
SEL
MUTE
ONLINE 2
WARNING
PREV
GAIN
Rear Panel
SERIAL I/O
SSPA LINK
AUX
OPTION 3 PARALLEL I/O
J3
J4
FOR CONTINUED PROTECTION AGAINST FIRE,
REPLACE ONLY WITH SAME TYPE AND RATING
OF FUSE.
85-264 V
47-63 Hz
J1
J2
RCP-2001
VX.XX
Connector Interface
Ref. Des.
Function
Connector Type
Mating Connector
Comment
J1
AC In
IEC 320
IEC Cordset
Standard
"
DC In
4-pin MS, Male
4-pin MS, Female
Option 5 or 6
J2
Serial I/O
9-pin D, Female
9-pin D, Male
Standard
J3
SSPA Link
9-pin D, Male
9-pin D, Female
Standard
J5
Parallel I/O
37-pin D, Male
37-pin D, Female
Option 3
Specifications
Parameter
Notes
Min.
Power Requirements
Voltage, Standard
Frequency
Power
Voltage, Option 5
Voltage, Option 6
85
47
Operating Temperature Range
Nom./Typ.
Max.
Units
20
42
265
63
13.5
32
56
Vac
Hz
W
Vdc
Vdc
0
+50
°C
SSPA Link Cable Length
4000 (1.3)
Size
†
†
19 W x 1.72 H x 17.52 D
482.6 x 43.7 x 445
ft (km)
inches
mm
When there is only one value on a line, the Nom./Typ. column is a nominal value; otherwise it is a typical value. Typical values are intended to
illustrate typical performance, but are not guaranteed.
Parallel I/O (Option 3)
The RCP-2001's parallel I/O (Option 3) provides eight independent contact-closure inputs and eight Form 'C' outputs. Each
input or output is easily configured via the RCP-2001's front panel display and an extensive menu of SSPA control and status
monitoring options.
Outputs *
Inputs *
No function
User Fault (Active High)
User Fault (Active Low)
Mute
Un-Mute
Mute/Un-Mute Toggle
Mute (Low)/Un-Mute (High)
RF Inhibit (Active Low)
RF Inhibit (Active High)
Fault Reset
No function (user-defined function)
Output Power Fault (High or Low)
Voltage Fault
Any Fault
Remote/Local Mode
Maintenance Mode
RF Inhibit
RF On/Off
Mute/Operate
Any Warning
Any Fault or Warning
Temperature Fault
Current Fault
Ratings
Inputs:
Contact closure to ground
(5 V/5 mA)
Outputs:
Form 'C' dry contacts
100 V/0.5 A/3 W maximum
* Additional functions may be offered for SSPAs with optional hardware features.
Other Products
•
•
•
•
•
•
•
•
•
Solid-State Power Amplifiers and SSPA Systems
Solid-State Power BUCs and SSPB Systems
Low Noise Amplifiers and LNA Systems
Low Noise Block Converters and LNB Systems
Block Up and Block Down Converters
Synthesized Converters
Line Drive Amplifiers
Power Supply Monitors
Redundant Control Panels for SSPAs, SSPBs, and LNAs
60 Decibel Road, Suite 200 • State College, PA 16801 USA • Tel. +1-814-238-2700 • FAX +1-814-238-6589
Email: satcom@gd-ms.com • www.gdsatcom.com/electronics.php
© 2015 General Dynamics. All rights reserved. General Dynamics reserves the right to make changes to its products and specifications at any time and without notice.
All trademarks indicated as such herein are trademarks of General Dynamics. All other product and service names are the property of their respective owners.
12724
Rev. A
Download