Technical Specifications WAGO reserves the right to carry out modifications on its products, in order to improve them, without prior notice. Safety and environmental conditions CE marking LV directive 2006/95/EC RoHS directive 2011/65/EU EN 60998-1:2004 EN 60998-2-3:2004 * EN 60947-7-3:2009 ** Standard * This product did not pass the temperature cycle test of par.15.102.1 of this standard when mounted on flexible (class 5) cable. The product does make a connection, but the voltage drop can be higher than specified in the standard ** Only applicable to article number 0855-8001 and 0855-8003 The Voltage Tap is only suitable for insulated wires. This product is designed to be safe under the following conditions: Safety instruction All activities for installation, commissioning and maintenance of this voltage tap must be performed by qualified personnel that have the knowledge of applicable safety precautions. This guide assumes that the reader of this document has sufficient electro-technical knowledge to understand the content of this document. WAGO Kontakttechnik GmbH & Co. KG Hansastraße 27 32423 Minden Deutschland http:\\www.wago.com General Installation Guide WAGO Voltage Taps The Product is an voltage tap for wire and can only be used measuring electrical voltages. The voltage tap is suitable for measurement purposes only. The voltage tap should be mounted on the primary conductors in a weather protected and dry location. Specifications Explanation of symbols Environmental conditions Standard: Class: Operating temp.: Relative humidity: Operating height: Protection degree: Pollution degree: Measurement category: Application conditions Insulation material: Umax: Test voltage: Impulse voltage: Imax: Voltage drop: Fuse: EN 60721-3-3:1996 3K3 +5°C … +55°C 5% … 85%, non condensing 2000 m over NN IP20, basic insulation 2 CAT III Sec. lead: Usability: Torque: PVC or XLPE 400Vac 3kV / 50Hz 6kV 1,2 / 50µs 2A <500mVac 2A, 450V, F, 70kA, 5x25mm, ceramic (SIBA Part.no. 7008913.2 ) 3 m (1mm² flexible) Multiple use, max. 24 times. 1.5 … 2.0Nm Storage Temperature: Relative humidity: Material: -20°C …. +70°C 5% … 85%, non condensing PA 6.6, UL94 V2 This product is designed according to the EN 60998-2-3:2004 standards and therefore this product meets the requirements of the Low Voltage Directive 2006/95/EC. Read the installation guide before mounting the product. Unprofessional work activities on electrical installations may result in a threat of danger to the life and health of human beings and livestock! RoHS Directive 2011/65/EU WAGO states that they only uses qualified component in their products from manufacturers, whose specifications meet or exceed the requirements of the European Directive for the Restriction of use of certain Hazardous Substances. 0855-8001 Voltage Tap with fuse 2.5 mm² … 6 mm² (phase) 0855-8002 Voltage Tap 2.5 mm² … 6 mm² (neutral) 0855-8003 Voltage Tap with fuse 10 mm² … 16 mm² (phase) 0855-8004 Voltage Tap 10 mm² … 16 mm² (neutral) Specifications per type 0855-8001 Cable Size Power cable feed-through Color 0855-8002 0855-8003 0855-8004 2.5 mm2 … 6 mm2 10 mm2 … 16 mm2 Ø 3 mm … 5 mm Ø 5 mm … 7 mm black blue black Fuse yes no yes no Weight (g) 28 g 20 g 29 g 21 g Height 59 mm 50 mm 59 mm 50 mm Diameter 23 mm 23 mm 23 mm 23 mm Read this installation guide before installing the product Always avoid working on live parts of an installation. blue rev. 18.02.2016 Assembly blue voltage tap Problem solving Attention The 0855-8002 / 0855-8004 are only meant for assembly on a neutral. 1. Ensure a safe working area during assembly, maintenance and inspection of the voltage tap. Disconnect the power of the primary circuit and make sure it cannot be enabled unintentionally. 2. Connect the secondary lead to the high impedance voltage input of the measurement instrument (e.g., voltage meter or voltage input of kWh-meter). 3. Mount the voltage tap around the wire which should be tapped be turning the lower part. Mount the voltage tap around the wire which should be tapped be turning the lower part. 4. Attention Please note, the head of the voltage tap should be positioned straight above the screw thread when mounting the voltage tap. Check if the voltage tap is mounted properly. Check if the secondary lead is connected properly and firmly. 5. Mark the label of the voltage tap with year, month and number of repeat installations. 6. Enable the primary circuit. Assembly black fused voltage tap Attention Remove the fuse during assembly of the 0855-8001 / 0855-8003 (black Voltage Tap). 1. 2. Ensure a safe working area during assembly, maintenance and inspection of the voltage tap. Disconnect the power of the primary circuit and make sure it can not be enabled unintentionally. 3. 4. 5. 6. 7. Connect the secondary lead to the high impedance voltage input of the measurement instrument (e.g., voltmeter or voltage input of kWh-meter). Check the settings of the meter by using the installation guide of the meter. Check whether the voltage tap is mounted on the intended cable. Attention Always follow the disassembling instructions when reversing the Voltage Tap. Disassembly instruction To disconnect the meter from the Voltage Tap, please consult the installation guide of the meter. Mark the label of the voltage tap with year, month and number of repeat installations. 1. Ensure a safe working area during disassembling the Voltage Tap. Disconnect the power of the primary circuit and make sure it cannot be enabled unintentionally. 2. 0855-8001 / 0855-8003 (black Voltage Tap) Remove the fuse and disconnect the measurement device. As next step remove the Tap from the connector. Wiring Diagram Install the fuse. Check if the voltage tap is mounted properly. Check if the secondary lead is connected properly and firmly. Enable the primary circuit. e.g. unexpected values, incorrect values 0855-8002 / 0855-8004 (blue Voltage Tap): Remove the Voltage Tap from the connector and disconnect the measurement device. 0855-8001 0855-8003 0855-8002 0855-8004 3. Repair or replace the wire after removal to ensure safe isolation. Not repairing the wire may result in an unsafe situation. 4. Enable the primary circuit if is necessary. Maintenance and inspection Check whether the secondary lead is connected firmly. Check whether the voltage tap is mounted firmly. Attention Always avoid working on live parts of an installation.