MODEL XR6 WIRING DIAGRAM Refer to the XR6 Installation Guide (LT-0229) for a complete description of wiring connections. Refer to the XR6 Programming Guide (LT-0230) for complete programming instructions. NFPA 72 Household Fire Warning This equipment should be installed in accordance with Chapter 2 of the National Fire Alarm UL Recognized limited energy cable Code, ANSI/NFPA 72-1996, (National Fire Protection Association, Batterymarch Park, Quincy, must be used for connection of all MA 02269). Printed information describing proper installation, operation, testing, maintenance, initiating, indicating, and evacuation planning, and repair service is to be provided with this equipment. Warning: Owner’s supplementary devices. instruction notice, not to be removed by anyone except occupant. Types of Service J11 When used with the 350A J16 1 Enclosure: 2 Command Processor Reset RJ Cable Monitor J7 3 suitable for Grade A Local and Use DMP Model 306 Harness 4 Police Connect Mercantile J7 Premises with basic line security, AC wiring must be in conduit and exit Grade A Local and Police Connect out the left side of the panel enclosure. J4 Mercantile Safe and Vault with Wiring on RJ SUP terminals 5 - 26 basic line security, Grade B Central must exit to the Phone Jack Connector Station and Grade A proprietary. right and maintain a 1/4” See sections 17.3, 18.6, 19.2, and separation from U11 19.5 - 19.7. the AC and Household System An alarm sounding device must be installed indoors so that it is clearly heard in all sleeping areas. Model 692 75mA @ 8 -16 VDC Bell GND Z4 Z5 Rear Tamper Z6+ Z6- 1K W 1K W 1K W Tamper protection when required for Model 350A Attack Resistant Enclosure. ZONE 6 ZONE 4 ZONE 3 ZONE 2 ZONE 1 22 GA. MIN BLACK 22 GA. MIN YELLOW 22 GA. MIN GREEN Cold Water Pipe Earth Ground 22 GA. MIN RED Maximum AC wire distance With 16 gauge wire: 70 feet With 18 gauge wire: 40 feet Bell 10.4 - 13.2 VDC Total current: 1.5 Amps max. w/ 40 VA 600mA w/ 20 VA Models 690, 790, 791, 793 100mA @ 8 - 16 VDC Programmer Header J8 Use DMP Model 330 Harness -B BELL GND RED YEL GRN BLK SMK Z1 GND Z2 Z3 16 - 18 gauge wire Secondary Power Supply 1.2 Amps max. charging current. Use only 12 VDC rechargeable batteries. DMP Model 367. Replace every 3 - 5 years. Keypads Models 670, 770, 771, 100mA @ 8 - 16 VDC 125mA with display lit +B Front Tamper controlled by switch. RED Model 324 16.5 VAC 20VA Class 2 plug-in PROG AC BLACK Model 321 16.5 VAC 40VA Class 2 plug-in J8 AC Output Header J11 All outputs must be connected to devices located within the same room as the control panel. Use DMP Model 300 Harness. EPROM Socket battery positive wiring. Suitable for Household Fire and Grade A Household Burglary. Test weekly. DMP transformers: Model 320 Plug into 120 VAC 16.5 VAC 40VA outlet not Class 2 wire-in POWER LIMITED All circuits on the Model XR6 comply with the requirements for inherent power limitation and are Class 2. 2-wire smoke detector 1K W Smoke Output 100mA @ 10.4 - 13.2 VDC Red Terminal 11 Black 1K W 4-wire smoke detector Up to 500mA auxiliary current at 10.4 - 13.2 VDC from Terminal 7. Power Supervision Relay Smoke Detector +- 3.3k W DMP Model 309 Zone 6 compatibility identifier: A Verification Zone 6* Control Unit Delay 13.6 sec. Maximum operating range: 8.8 VDC 14.2 VDC. See section 11.1 in the XR6 Installation Guide (LT-0229) for a list of approved 2-wire smoke detectors. Smoke Model Detector Delay ______ _____ sec. Heat detectors, manual pull stations, or any other shorting device. Unlimited number of units. WARNING THIS UNIT MAY BE PROGRAMMED TO USE AN ALARM VERIFICATION FEATURE THAT RESULTS IN A DELAY OF THE SYSTEM ALARM SIGNAL FROM THE INDICATED CIRCUITS. THE TOTAL DELAY (CONTROL UNITS PLUS SMOKE DETECTORS) SHALL NOT EXCEED 60 SECONDS. NO OTHER SMOKE DETECTOR SHALL BE CONNECTED TO THESE CIRCUITS UNLESS APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION. LT-0445 (3/01)