EDGE EV3H 3” (76.2mm) G1/G9/GS: 3-13/16” Project3-13/16” Name (96.8mm) Date 4-1/8” (104.8mm) Catalog Number Type FL & FLF: E V O L U T I O N LED Recessed Linear with Arched Regress Lens CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Highly reflective die-formed white painted steel reflector, .125” (3.2mm) diffuse snap-in arched acrylic lens with matte finish, removable for maintenance. ELECTRICAL Electronic, 120 to 277 volt input and 36V output. 0-10 volt dimming standard. Must specify 1D in circuiting for dimming. LED All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80. R9≥20, 27K is CRI≥90, 30K, 35K, and 40K is CRI≥82. Minimum lifetime greater than 60,000 hours. MOUNTING Edge is designed to install into acoustical grid and inaccessible ceilings. Specify GXG, FLF, SFS, NFN for individual, unjoinable units (individual units will fall on-grid). Specify GX, FL, SF, NF for continuous runs (runs designed to fall on-grid). Grid retention brackets are integral to housing. Each housing contains 4 grid retention brackets. Consult factory for detailed installation instructions. FINISH Standard powder-coat textured white, metallic silver, textured black, graphite or bronze painted finish, consult factory for chip of standard paint finishes. Contact factory for additional custom color and finish options. WARRANTY Edge LED offered with a 5-year limited warranty. Covers LED, driver and fixture. LABELS IC Rated, UL and cUL Listed, approved for dry/damp location unless otherwise noted. YEAR LED WARRANTY LFL Convertible LED 5-1/8” YEAR LED WARRANTY LED (130.2mm) LFL LED Convertible Convertible LFL Convertible LED LFL 3” (76.2mm) G1/G9/GS: 3-13/16” (96.8mm) FL & FLF: 4-1/8” (104.8mm) L U M I N A I R E S P E C I F I C AT I O N Sample Catalog #: EV3H-30-24’-FL-120-1C-W EV3H- ____- ___’- ___- ___- HOUSING COLOR/LUMENS LENGTH MOUNTING VOLTAGE 1 LFL Convertible Individual Units 2- 2’, 23” (584.2mm) fixture2 3- 3’, 35” (889mm) fixture2 4- 4’, 47” (1193.8mm) fixture2 5- 5’, 59” (1498.6mm) fixture2 6- 6’, 71” (1803.4mm) fixture2 8- 8’, 95” (2413mm) fixture2 Continuous Runs3 xx’- Specify row length to 1’ (304.8mm) increments 27K Color Temperature Lumen Options 27- 27K, 266 lumens/ft (5.2 watts/ft) 27HO- 27K, 482 lumens/ft (9.9 watts/ft) 30K Color Temperature Lumen Options 30- 30K, 325 lumens/ft (5.2 watts/ft) 30HO- 30K, 587 lumens/ft (9.9 watts/ft) 35K Color Temperature Lumen Options 35- 35K, 339 lumens/ft (5.2 watts/ft) 35HO- 35K, 613 lumens/ft (9.9 watts/ft) 2 EV3H- Edge Evolution 3, Arched Regress Lens 40K Color Temperature Lumen Options 40- 40K, 348 lumens/ft (5.2 watts/ft) 40HO- 40K, 629 lumens/ft (9.9 watts/ft) Custom Output CL_____- Specify color temp. and lumens/ft. (i.e. CL35500) CW____- Specify color temp. and wattage/ft. (i.e. CW407.5) (Specify lumens/watts between standard offering listed above. Lumens are specified per color temp.) __- YEAR LED WARRANTY LED CIRCUITING LED ____ FINISH OPTIONS (130.2mm) Convertible 1C120- 120 V 1D277- 277 V 1BUNV- UNV 3” (76.2mm) (120-277) G1/G9/GS: 1E3-13/16” (96.8mm) FL & FLF: 5-1/8” __- LFL Single Circuit Single Circuit Dimming5 Single Circuit with Battery Pack5,9 Single Circuit with Emergency Circuit 4-1/8” (104.8mm) Individual Units (CANNOT BE JOINED)2 Acoustical Grid Ceiling10 G1G- 1” (25.4mm) Ceiling Grid G9G- 9/16” (14.3mm) Ceiling Grid GBG- 9/16” (14.3mm) Ceiling Grid with Bevel Trim GSG- Screw Slot Ceiling Grid Inaccessible Ceiling 5-1/8” FLF- Standard 1/2” (12.7mm) (130.2mm) Flange SFS- Spackle Flange NFN- Flangeless4 Continuous Runs (JOINABLE)3 10 Acoustical Grid 3” Ceiling (76.2mm) G1- 1” (25.4mm) Ceiling Grid G1/G9/GS: G9- 9/16”3-13/16” (14.3mm)(96.8mm) Ceiling Grid G9- 9/16” (14.3mm) FL & FLF:Ceiling Grid with Bevel Trim GS- Screw4-1/8” Slot Ceiling Grid (104.8mm) Inaccessible Ceiling FL- Standard 1/2” (12.7mm) Flange SF- Spackle Flange NF- Flangeless4 W- Matte White S- Metallic Silver BL- Textured Black GR- Graphite BR- Bronze CC- Custom Color CPMRFLMRFPMRC- Chicago Plenum Fixed MR16 Halogen8 Fixed MR16 LED8 Perimeter Mount6 Rotating Crossbar7 See back page for mounting detail. 2Individual units cannot be joined. All end trims are factory installed and cannot be removed in the field. 3Continuous Rows made up of both even and odd length fixtures. Designed to fall on-grid. 4NF and NFN to be utilized for metal pan / millwork ceiling. 5Some Edge configurations will not accommodate all electrical options. Consult factory. 6Available for acoustical grid ceilings. Wall rail painted white unless otherwise specified. 71/2” to 5/8” drywall thickness. Available for standard 1/2” flange (FL). 8Consult MR16 Resource Guide for configurations using MR16 units. 9 Integral battery packs with remote test switch are provided with 1B option. 10 See page 3 for grid retention bracket details. 1 ® Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® August 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. 1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings. EDGE EVOLUTION EV3A, EV3AL, EV3H INDIVIDUAL AND CONTINUOUS RUN MODULES 1 23" (584.2mm) 2' 59” (1498.6mm) or 60” (1524mm) 5' (1) lens per 2' unit (1) lens per 5' unit 71” (1803.4mm) or 72” (1828.8mm) 35" (889mm) 3' 6' (1) lens per 3' unit (1) lens per 6' unit 47” (1193.8mm) or 48” (1219.2mm) 4' 95” (2413mm) or 96” (2438.4mm) 8' (1) lens per 4' unit (1) lens per 8' unit 1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings. MOUNTING DETAILS 1” Grid Mounting Options 9/16” Grid Mounting Options Screw Slot Mounting 1” Grid, Standard Tile: 1” Grid, Tegular Tile: 9/16” Grid, Standard Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: 9/16” Grid, Tegular Tile: Screw Slot Grid: Use G1 or G1G in part # Use G1 or G1G in part # Use G9 or G9G in part # Use G9 or G9G in part # Use GB or GBG in part # Use GS or GSG in part # Use GS or GSG in part # INACCESSIBLE CEILING MOUNTING Flange Detail Non-Flange SPECIALTY MOUNTS Spackle Flange Exposed Flange Detail: Metal Pan or Millwork: Drywall, Flangeless Look: Specify FL or FLF in part # Specify NF or NFN in part # Specify SF or SFS in part # MR16 LAMP Perimeter Mount Rotating Crossbar Bracket and Wall Rail: Specify PM in part # Unavailable Structure Support: Specify RC in part # APPLICATION: MR16’s are ideal for conference rooms, corridors, wall washing, retail spaces and training facilities where accent lighting is required. ELECTRICAL: Standard 50 watt max halogen lamp transformer (120v or 277v), 60 watt max LED electronic transformer (120v or 277v). MR16 installed as independent circuit. MR16 voltage to match LED voltage. TECHNICAL: MR16 fully enclosed compartment eliminates light from entering into other fixture areas. Available in 20, 35 and 50 watt halogen lamps, up to 12 watt LED lamps (lamps not included). Consult factory for other lamp types/ wattages. LABELS: UL and cUL Listed, approved for dry/damp location unless otherwise noted. ® ORDERING INFORMATION: MR16 layout guide. MR16’s should be specified utilizing Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® August 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions. PHOTOMETRICS EDGE EVOLUTION Joint holes Joint for holes #8-32 for #8-32 ScrewsScrews GRID RETENTION: At every joint, the addition of grid retention brackets results in a sturdy connection between the fixtures and the grid. Insert screws through the bracket into the grid to secure. JOINT ALIGNMENT: Incorporating biscuits and screws not only creates a secure joint but also aids in fixture alignment. BiscuitBiscuit ® Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239 Phone 303.322.5570 Fax 303.322.5568 www.pinnacle-ltg.com © 2016 Pinnacle Architectural Lighting® August 2016 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.