PowerMate ™ Plugs, Receptacles and Connectors POWERMATE DRILLING RIG POWER CONNECTIONS TABLE OF CONTENTS Applications ..................................................... 2 The PowerMate offering is designed to support modularity of drilling rig systems by providing safe and reliable power connections for riggingup and rigging-down equipment quickly and efficiently. Specifiable Features ........................................ 3 The PowerMate product offering is also compatible with all UL 1686 listed plugs and receptacles, including: Ř Cooper Crouse-Hinds Arktite™ Ř Appleton Powertite® Ř Killark VersaMate® Certifications ................................................... 3 Standard Finishes............................................ 3 Options ............................................................ 3 PowerMate™ Features and Benefits .............4-5 PowerMate™ Offering: 30A .................................................................. 6 60A .................................................................. 7 100A ................................................................ 8 150A ................................................................ 9 200A and 400A Offering .................................. 9 APPLICATIONS Grounding...................................................... 10 PowerMate Plugs, Receptacles, and Connectors are used: Ř On SCR/VFD houses to provide power to rig equipment such as shakers, agitators, lighting circuits, mud pumps, motors, etc. Ř To quickly and efficiently connect power during rig-ups and disconnect power during rig-downs. Electrical Rating Ranges ............................... 10 Product Dimensions ...................................... 11 Replacement Parts ........................................ 12 Wire Sizes ...................................................... 12 PowerMate™ Part Numbers ........................... 13 Plug and Receptacle Solutions for Land-Based Drilling ............................14-15 2 Lockout Plug Safety Insulator Diamond Clamp Standard Materials .......................................... 3 This offering is the ideal rig power connection solution providing: Ř Longer product life Ř Reduced maintenance Ř Enhanced safety Ř Easy installation SPECIFIABLE FEATURES Split Pin Contacts STANDARD MATERIALS Ř Receptacle housing, plug and cord connector bodies - high impact strength copper-free aluminum (less than 0.4% copper) Ř Back boxes - cast aluminum Ř Insulation - fiberglass reinforced polyester Ř Contacts - naval brass Type P Cable STANDARD FINISHES CERTIFICATIONS Ř UL Standards: UL 1682, UL 1686, NEMA 250 Ř CSA Standard: C22.2 No. 182.1 Ř Listed for use with Type P cable, flexible cord and cables rated for extra hard usage Ř NEMA 4X Ř Copper-free aluminum - epoxy powder coat Ř Fiberglass reinforced polyester - natural (red) Ř Naval brass - natural OPTIONS Ř -RS...Reverse Service. Receptacle assembled with plug interior and plug assembled with receptacle interior. For applications where plug is energized to feed normally de-energized receptacle. NOTE: 30, 60, and 100A interiors can be interchanged in the field using a screwdriver. CDR - S22 (reverse service) PowerMate Receptacle Transformer Switch CCP PowerMate Plug Generator CCP - RS (reverse service) PowerMate Plug CDR - RS PowerMate Receptacle Ř -P4...Special Polarity. Receptacle interior rotated 22 1⁄2 degrees to right and plug changed to match. For use where two or more receptacles of the same ampere rating, style, and number of poles are to be installed in the same area for use on different voltages and/or frequencies. Prevents insertion of a plug in a receptacle with different electrical rating. 3 PowerMate ™ Features and Benefits 1 Lockout Plug (Patent Pending) Ř*XDUDQWHHVLVRODWHGSRZHUVXSSO\ZLWK26+$FRPSOLDQWORFNRXWWDJRXW Ř(QVXUHVSOXJFDQQRWEHLQVHUWHGLQWRUHFHSWDFOHZKHQPDLQWHQDQFHLV being performed downstream of power supply. 2 Fixed Safety Insulator (Patent Pending) Ř3UHYHQWVHOHFWULFDOVKRFNDQGVKRUWVZLWKSODVWLFEDUULHUEHWZHHQLQVXODWRU body and metal housing. Ř)L[HGLQSODFHGHVLJQHQVXUHVLQVXODWRUZLOOQRWEHORVWRUGLVFDUGHG during cable termination process. 3 8-Point Diamond Cable Clamps (Patent Pending) ŘSRLQWVRIFRQWDFWDURXQGGLDPHWHURIFDEOHIRULQFUHDVHGJULSDQGHYHQ distribution of pressure. Ř&DEOHMDFNHWGRHVQRWJHWSLQFKHGHOLPLQDWLQJSRWHQWLDOIRUGDPDJH to internal conductors. 4 Split Pin Contact Design Ř3URYLGHVQHDUO\rRIFRQWDFWDWHYHU\LQVHUWLRQHQVXULQJSURWHFWLRQ against heat rise and eliminating arcing on critical surfaces. Ř6HOIZLSLQJDWHYHU\LQVHUWLRQWRUHPRYHIRUHLJQSDUWLFOHVWKDWFUHDWH electrical resistance and product failure. 5 Extended Cable Range Ř,QGXVWU\őVODUJHVWFDEOHGLDPHWHUUDQJH Ř6SHFLƂFDOO\GHVLJQHGWKLUGSDUW\WHVWHGDQGFHUWLƂHGIRUXVHZLWK7\SH3 cable. Ř6HDOLQJV\VWHPXWLOL]HVLQGXVWU\VWDQGDUGEXVKLQJV 6 Enhanced Nomenclature and Nameplate Ř(DVLO\XQGHUVWDQGDEOHQRPHQFODWXUHLQFUHDVHVHDVHRISDUWFRQƂJXUDWLRQ identification. Ř0HFKDQLFDOO\DWWDFKHGQDPHSODWHHQVXUHVWKDWFULWLFDOLQIRUPDWLRQLV permanently fixed to product. 7 Spring and Threaded Cover Ř(DFKUHFHSWDFOHFRPHVZLWKERWKVSULQJFDSDQGWKUHDGHGFDSWRSURYLGHD variety of cover options. 8 Combination Drive Stainless Steel Hardware Ř,QFUHDVHVHDVHRILQVWDOODWLRQE\DOORZLQJIRUPRUHWKDQRQHRSWLRQIRU installation tools. Ř6WDLQOHVVVWHHOH[WHUQDOKDUGZDUHHOLPLQDWHVFRUURVLRQRQFULWLFDO components and extends product life. 9 Handle Body Ř7KLFNHSR[\SRZGHUFRDWLQJLVVWDQGDUGƂQLVKRQ3RZHU0DWHSURGXFWV Ř&RDWLQJUHGXFHVFRUURVLRQDQGLQFUHDVHVOLIHRISURGXFW Ř,QGXVWU\VWDQGDUGSURƂOHLQFUHDVHVHDVHRISOXJJLQJDQGXQSOXJJLQJ 10 Combination Slot and Hex Mechanical Lugs* Ř,QFUHDVHVHDVHRILQVWDOODWLRQE\DOORZLQJIRUPRUHWKDQRQHRSWLRQIRU installation tools. Ř+H[KHDGDOORZVIRUHDV\DFKLHYHPHQWRIVSHFLƂHGWRUTXHYDOXH 11 Insulator Assemblies Ř8QLPSHGHGHDV\DFFHVVSKDVHDQGJURXQGWHUPLQDOVPDNHZLUH termination quick and easy. Ř0ROGHGLQSODFHPDUNLQJVIRUSKDVHJURXQGDQGFRQGXFWRUVWULSOHQJWKV reduce installation errors.* Specifiable Features Lockout Plug Safety Insulator Diamond Clamp Split Pin Contacts Type P Cable Compatible with all UL 1686 listed plugs and receptacles. Type P Cable Lockout Compliant *60, 100, and 150A offering. 4 5 150 AMP 100 AMP Receptacles, Plugs and Connectors Receptacles, Plugs and Connectors NEMA 4X Watertight 600 VAC / 250 VDC 50 - 400 Hz NEMA 4X Watertight 600 VAC / 250 VDC 50 - 400 Hz DESCRIPTION AND CONFIGURATION: 2 Wire 2 Pole Style 1 RECEPTACLE CABLE RANGE CDR1022 CORD CONNECTOR PLUG CAT. NO. .875-1.906” CCP1022CD CABLE RANGE CAT. NO. .875-1.906” CRC1022CD GR GR 2 Wire 3 Pole Style 2 GR 3 Wire 3 Pole Style 1 GR CDR1023 CDR1033 .875-1.906” CCP1023CD .875-1.906” CCP1033CD .875-1.906” CRC1023CD .875-1.906” CRC1033CD DESCRIPTION AND CONFIGURATION: 3 Wire 4 Pole Style 2 4 Wire 4 Pole Style 1 RECEPTACLE CORD CONNECTOR PLUG CABLE RANGE CAT. NO. CABLE RANGE CAT. NO. .875-1.906” CCP15034CD .875-1.906” CRC15034CD CDR15034 1.250-2.190” CCP15034DE 1.250-2.190” CRC15034DE GR .875-1.906” CCP15044CD .875-1.906” CRC15044CD CDR15044 1.250-2.190” CCP15044DE 1.250-2.190” CRC15044DE GR Back Boxes (for Receptacles) - see page 8. 200 AMP and 400 AMP Arktite ™ 3 Wire 4 Pole Style 2 CDR1034 .875-1.906” CCP1034CD .875-1.906” CRC1034CD GR Receptacles, Plugs and Connectors 4 Wire 4 Pole Style 1 200A and 400A options available as part of our Cooper Crouse-Hinds Arktite™ Series CDR1044 .875-1.906” CCP1044CD .875-1.906” CRC1044CD GR AMPERAGE AND CONFIGURATION: RECEPTACLE PLUG CORD CONNECTOR Back Boxes (for Receptacles) HUB SIZE CJA ⁄2” CJA310 1-1⁄4” CJA410 1-1⁄2” CJA510 2” CJA610 1 CJA ADAPTER ONLY CJA100 8 Ř7KHEDFNER[HVDWOHIWDUHVWDQGDUGZLWK Corro-Free™ epoxy powder coat finish for increased corrosion resistance. Ř)RURSWLRQDOUHYHUVHGLQWHULRUXVHVXIƂ[-RS (see page 3). Ř)RURSWLRQDOURWDWHGLQWHULRUXVHVXIƂ[-P4 (see page 3). Ř)RUGLPHQVLRQVVHHSDJH Ř0D[LPXPFRQGXFWRUVL]HZLUHZHOOŔ (see page 12). 200A 2 Wire 3 Pole - Style 2 3 Wire 3 Pole - Style 1 3 Wire 4 Pole - Style 2 4 Wire 4 Pole - Style 1 400A 2 Wire 3 Pole - Style 2 3 Wire 3 Pole - Style 1 3 Wire 4 Pole - Style 2 4 Wire 4 Pole - Style 1 For detailed part numbers and technical information, please refer to section 1P of the Cooper Crouse-Hinds catalog. 9 PowerMate ™ Plugs, Receptacles and Connectors Grounding Product Dimensions Style 1 Receptacle, Plug, Cord Connector CDR Receptacle Style 1 units complete the grounding circuit through the metallic plug shell, receptacle housing, or connector shell. Style 2 a b 30A 2-7⁄8” 3-3⁄8” 60A 3p 4-1⁄4” 60A 4p 4-1⁄4” CCP Plug† CRC Cord Connector† a b a b 6-1⁄2” 2-5⁄16” 6-3⁄5” 2-9⁄16” 4-1⁄2” 8-1⁄6” 3-5⁄8” 4-1⁄2” 8-1⁄6” 3-3⁄4” a b 100A 3p 5-1⁄4” 4-1⁄4” 10-4⁄5” 3-3⁄4” 100A 4p 1 5- ⁄4” 1 4- ⁄4” 150A (CD) 5-1⁄4” 4-1⁄4” 150A (DE) 5-1⁄4” 4-1⁄4” a b 8-3⁄10” 2-5⁄16” 8-3⁄10” 2-5⁄16” 11-1⁄2” 3-3⁄16” 10- ⁄5” 1 4- ⁄8” 11- ⁄2” 3- ⁄16” 10-4⁄5” 4-1⁄8” 11-1⁄2” 3-7⁄16” 10-4⁄5” 4-1⁄8” 11-1⁄2” 3-7⁄16” 4 1 a b 7 †Dimensions are approximate and vary with cable size. CEE Back Boxes Style 2 metallic units with metal housing have a separate designated ground contact that is bonded to the metallic housing. The metallic housing of the plug, receptacle, or connector forms a parallel ground circuit through the receptacle or connector detent spring. Electrical Rating Ranges Ř9ROWDJH 600 VAC, 50 to 400 Hz; 250 VDC* Ř$PSHUHV 30, 60, 100, 150 Motor Horsepower ** 10 Rating CEE13 30A Size 1 a ⁄2 1-27⁄32” 11 60A 30A b ⁄16” CEE23 30A 3 ⁄4 1-27⁄32” 13 CEE33 30A 1 1-31⁄32” 15 CEE36 60A 1 2-9⁄16” CEE46 60A 1-1⁄4” 2-5⁄8” 1-3⁄16” CEE56 60A 1-1⁄2” 2-11⁄16” 1-5⁄16” ⁄16” ⁄16” ⁄16” 15 CJA Maximum Horsepower for Plug and Receptacle Combinations by Input Voltage** The following values are typical horsepower ratings based on NEC Article 430 tables. HP Ratings are based on the largest conductor size for each plug and receptacle combination per the Wire Size table below. Ampere Rating Plug and Receptacle Cat. No. 240 Volts 480 Volts 600 Volts 30 15 30 40 60 20 40 50 100 30 60 75 150 40 75 100 200 60 125 150 * This guide is for reference only. Consult your local electrical codes before installation. ** Cooper Crouse-Hinds recommends circuit breaking use be limited to emergency conditions only and that a horsepower rated switch or Cooper Crouse-Hinds ,QWHUORFNHG5HFHSWDFOHEHXVHGIRUPDNLQJDQGEUHDNLQJ under load. With 60, 100 and 150A Angle Adapters Cat. No. Hub Size a b c d e f CJA310 1” 5-7⁄8” 8” 7-7⁄16” 4-7⁄8” 7” r CJA410 1-1⁄4” 5-7⁄8” 8” 7-7⁄16” 4-7⁄8” 7” r CJA510 1-1⁄2” 5-7⁄8” 8” 7-7⁄16” 4-7⁄8” 7” r CJA610 2” 5-7⁄8” 8” 8” 4-7⁄8” 7” r Ř%DFNER[HVDUHVWDQGDUGZLWK&RUUR)UHH™ epoxy powder coat finish for increased corrosion resistance. Ř7KUXIHHGEDFNER[HVDUHIXUQLVKHGZLWKRQHFORVHXSSOXJLQERWWRPUHFHVVHGKXE Ř&-$EDFNER[HVDUHUHFRPPHQGHGZKHQDGGLWLRQDOZLULQJVSDFHLVUHTXLUHG Ř7KHDQJOHDGDSWHURQ&-$EDFNER[HVFDQEHLQVWDOOHGDWrURWDWLRQVPDNLQJLWSRVVLEOHWRHQWHUKXEIURPVHYHUDO directions. 11 PowerMate ™ Plugs, Receptacles and Connectors PowerMate™ Part Numbers Replacement Parts Standard Replacement Parts CCP Replacement Interiors 30, 60, 100, 150A Complete insulator and contact assembly 2W2P 2W3P 3W3P 3W4P 4W4P CDR-CRC 30A 60A 100A 150A &5, &5, &5, --- CCP &3, &3, &3, --- CDR-CRC &5, &5, &5, --- CCP &3, &3, &3, --- CDR-CRC &5, &5, &5, --- CRI Receptacle & Connector Interior CCP &3, &3, &3, --- CDR-CRC &5, &5, &5, &5, CCP &3, &3, &3, &3, CDR-CRC &5, &5, &5, &5, CCP &3, &3, &3, &3, CPI Plug Interior Miscellaneous Replacement Parts Amperage Configuration Center Center CDR Spring Cover CDR Threaded Cover CCP Fastening Ring Bushings Kits Center 30A 2-pole, 3-pole 4-pole PTSC30 PTTC30 CLMPR30 PTGB30 60A 2-pole, 3-pole 4-pole PTSC60A PTSC60B PTTC60A PTTC60B CLMPR23P60 CLMPR4P60 PTGB60 100A 2-pole, 3-pole 4-pole PTSC100A PTSC100B PTTC100A PTTC100B CLMPR23P100 CLMPR4P100 PTGBCD CLMPR4P150 PTGBCD (CD Size) PTGBCD (DE Size) 150A 4-pole PTSC150B PTTC150B Spring Cover Threaded Cover Diameter of Wire Recess in Plug & Receptacle Contacts Amperage Rating Contact Type Diameter of Recess Wire Size †† Extra Flex 30 (2, 3, & 4-pole) Pressure .281” #10-#8 60 (2, 3, 4-pole) Pressure .312” #8-#4 100 (2, 3, & 4-pole) Pressure .390” #4-#2 150 (4-pole) Pressure .390” #2-1/O 3 4 BC RS PRODUCT TYPE CCP - Plug CDR - Receptacle CRC - Connector CDRE - Receptacle with CEE Back Box CDJA - Receptacle with CJA Back Box AMPERAGE 30 - 30 Amp 60 - 60 Amp 10 - 100 Amp 150 - 150 Amp (200 & 400 Amp options avail. as part of Arktite Series)* WIRE 2 - 2-Wire 3 - 3-Wire 4 - 4-Wire Wire Sizes The table below lists the diameter of the wire recess in PowerMate plug and receptacle contacts so that maximum size of bare conductor can be determined. Range of wire sizes shown in table are intended only as a guide. Depending on type of wire used (building wire, flexible or extra flexible cable) and its construction (number and size of strands), bare copper diameters vary widely. 30 POLE 2 - 2-Pole 3 - 3-Pole 4 - 4-Pole CABLE RANGE ** (plug and connector only) BC - 0.390” to 1.375” CD - 0.875” to 1.906” DE - 1.250” to 2.190” E - 1.875” to 2.500” F - 2.500” to 3.000” G - 3.000” to 3.500” HUB SIZE*** (receptacle with back box only) 50 - 1⁄2” 75 - 3⁄4” 100 - 1” 125 - 1-1⁄4” 150 - 1-1⁄2” 200 - 2” 250 - 2-1⁄2” 300 - 3” 350 - 3-1⁄2” 400 - 4” 500 - 5” OPTIONS RS - Reverse Service P4 - Special Polarity Bushing Kit * Refer to section 1P of the Cooper Crouse-Hinds catalog. ** Cable Range only applies to specific plug part numbers. *** Hub size only applies to specific receptacle part numbers. ††Do not use wire size smaller than minimum size recommended. 12 13 It’s about knowing your challenges inside out Plug and Receptacle Solutions for Land-Based Drilling Drilling Rig Locations 1 Derrick/Mast 2 VFD/Generator(s) 3 Fuel Tank Product Photo Environmental Conditions 1 4 ,QGXVWULDO Motor Control/VFD/ SCR House(s) 5 Doghouse/ 2SHUDWRUőV+RXVH 6 Power/Pump Station 7 Shale Shaker Areas prone to dust, dirt, grime, vibration, hard use and abuse. Wet Locations 8 Protection from wind-blown dust and rain, splashing and hose-directed water and external formation of ice. Mud Tanks/Pumps Vibration 9 10 Locations that need products designed to withstand continuous movement and may require maintenance and repair. Drawworks & Top Drive Drilling Floor Corrosive Areas Protection for areas with corrosive chemicals, atmospheres and water. 3 Space Constraints 2 5 4 Areas with low ceilings, tight spaces and limited footprint potential. &ODVV,'LY=RQH 10 6 9 7 8 Explosion protection for areas with flammable gases or vapors normally in the atmosphere. &ODVV,'LY=RQH Explosion protection for areas where flammable gases or vapors are not normally present. &ODVV,,=RQH Protection for areas where ignitable dusts may be present. Please refer to your own company documentation for exact specifications and environmental conditions. 14 Product Solutions Env. Conditions Rig Location PowerMate Series Ř6XSSOLHVSRZHUWRSRUWDEOHGHYLFHVVXFKDVPRWRUJHQHUDWRUVHWVFRPSUHVVRUVKHDWLQJFRROLQJZHOGHUV and lighting from 30 to 150A Ř1(0$;FRSSHUIUHHDOXPLQXPFRQVWUXFWLRQZLWKHSR[\SRZGHUFRDWƂQLVKLVLGHDOIRUKDUVKHQYLURQPHQWV Ř$UFVQXIƂQJGHVLJQHQDEOHVODUJHSRZHUORDGVWREHGLVFRQQHFWHGXQGHUORDGZLWKRXWDQDUFƃDVKXSWR 100 amps) ŘrVSOLWSLQFRQWDFWUHGXFHVKHDWULVHDQGHOLPLQDWHVDUFLQJ Ř/RFNRXWWDJRXWKROHLQSOXJWRHQVXUHLWFDQQRWEHLQVHUWHGLQWRUHFHSWDFOHZKHQPDLQWHQDQFHLVEHLQJ performed downstream ,QGXVWULDO Wet Locations Vibration Corrosive Areas Space Constraints ENR & ENP Series Ř([SORVLRQSURRIRXWOHWIRUFRQYHQLHQFHDQGOLJKWLQJFRQQHFWLRQV$0$; Ř)DFWRU\VHDOHGFKDPEHUHQFORVHVSRWHQWLDODUFLQJFRPSRQHQWVEHWZHHQWZRH[SORVLRQSURRIWKUHDGHG MRLQWV Ř)UXVWUDWLRQIUHH(13ZLWKFDSWLYHVHWVFUHZVDVVXUHVHDVHRILQVWDOODWLRQDQGUHGXFHVOLNHOLKRRGRIORVLQJ critical components in the field Ř(1506HULHVZLWKJDVNHWHGVFUHZFDSFRYHURIIHUVIHDWXUHVWKDWSURWHFWLQWHULRUIURPKDUVKHQYLURQPHQWV provide time saving saddle clamp terminals, and improved safety with lockout/tagout hole ,QGXVWULDO Vibration Space Constraints &ODVV,'LY=RQH &ODVV,'LY=RQH FSQC & EBBR Series Ř,QWHUORFNHGXQLWVZLWKGHDGIURQWUHFHSWDFOHVHQVXUHFRQQHFWLRQFDQQRWEHPDGHRUEURNHQXQGHUORDG increasing safety and protection Ř3RZHU0DWHSOXJVFDQEHXVHGZLWKERWK)64&$(%%5$6HULHVWRSURYLGHXOWLPDWH flexibility of portable equipment used throughout the rig Ř)64&XQLWVDUHLQWHUORFNHGZLWKVZLWFKHVDQGWKH(%%56HULHVLVLQWHUORFNHGZLWKFLUFXLWEUHDNHUVIRU added protection ,QGXVWULDO Wet Locations Vibration Corrosive Areas Space Constraints &ODVV,'LY=RQH &ODVV,'LY=RQH 4, 7, 8, 10 CES & CPH Series Ř(TXLSSHGZLWKDGHOD\HGDFWLRQURWDWLQJVOHHYHZKLFKSUHYHQWVFRPSOHWHZLWKGUDZDORI&3+SOXJLQRQH continuous movement Ř7KHGHOD\HGDFWLRQIHDWXUHSHUPLWVWKHSOXJWREHXVHGDVDQHPHUJHQF\SXVKSXOOVZLWFK Ř5HFHSWDFOHVDUHIDFWRU\VHDOHGWRVLPSOLI\LQVWDOODWLRQDQGHOLPLQDWHWKHQHHGIRUH[WHUQDOVHDOV Ř$YDLODEOHLQDQG$ Ř&3+DOVRPDWHVZLWK)64&(3&DQG(%%5UHFHSWDFOHVRIPDWFKLQJFRQƂJXUDWLRQ ,QGXVWULDO Wet Locations Vibration Corrosive Areas Space Constraints &ODVV,'LY=RQH &ODVV,'LY=RQH 7, 8 eXLink® Connectors Ř6LJQDODQGSRZHUFRQQHFWLRQVFDQEHVZLWFKHGXQGHUORDG Ř5HGXFHVLQVWDOODWLRQWLPHSURYLGLQJPDLQWHQDQFHDQGODERUVDYLQJV Ř&DQEHIDFWRU\LQVWDOOHGDQGSUHZLUHGZLWK&RRSHU&URXVH+LQGVLQGXVWU\OHDGLQJOLJKWƂ[WXUHV Ř5DWHGXSWRPD[$DQGXSWR9 ,QGXVWULDO Wet Locations Vibration Corrosive Areas Space Constraints IEC 309 GHG 51 Series Ř6XSSOLHVSRZHUWRSRUWDEOHGHYLFHVZLWKUHTXLUHPHQWVRI$ Ř5HLQIRUFHGSRO\HVWHUFRQVWUXFWLRQRIIHUVUHOLDELOLW\IURPrWRr& Ř,QWHJUDWHG$&UDWHGGLVFRQQHFWVZLWFK Wet Locations Vibration Corrosive Areas &ODVV,'LY=RQH Roughneck™ Connectors Ř)RUXVHZLWKVLQJOHFRQGXFWRU0&0FDEOHYROWV$&'&UDWHGXSWR$ Ř'HVLJQHGIRUKHDY\DEXVHUHVLVWDQWWRUDLQPXGDQGRLO Ř4XLFNO\FRQQHFWVDQGGLVFRQQHFWVZLWKRXWDQ\WRROV Ř6XSHULRUVDIHW\SURWHFWLRQZLWKWRWDOO\VKLHOGHGFRQWDFWV Ř&RORUFRGHGLQVXODWRUVIRUHDV\LGHQWLƂFDWLRQWRSUHYHQWUHYHUVHSKDVLQJLQ$&DQGFURVVSRODUL]DWLRQLQ'& Ř0DWHGDVVHPEOLHVDUHORFNRXWWDJRXWFRPSDWLEOH ,QGXVWULDO Wet Locations Vibration Corrosive Areas Space Constraints Pauluhn™ 80/86/96/wd (NRL) Connectors Ř:DWHUWLJKW$16,1(0$W\SHUHFHSWDFOH Ř$FFHSWVVWDQGDUG$16,1(0$W\SHSOXJV Ř0DWLQJSOXJVZLWKLQWHJUDOWKUHDGHGULQJPDLQWDLQDZDWHUWLJKWVHDO Ř$YDLODEOHLQVHYHQGLIIHUHQWYROWDJHFRQƂJXUDWLRQVXSWR$ Ř&DSWLYHWKUHDGHGUHFHSWDFOHFDS ,QGXVWULDO Wet Locations Vibration Corrosive Areas Space Constraints Pauluhn™ PPR Series Connectors Ř:DWHUWLJKWQRQPHWDOOLFFRQVWUXFWLRQLQFOXGLQJZDWHUVKHGGLQJUHFHSWDFOHGHVLJQ Ř&RUURVLRQDQGLPSDFWUHVLVWDQWFORVXUH Ř&DSWLYHWKUHDGHGUHFHSWDFOHFDS Ř3:DQG3:DYDLODEOHLQVLQJOHRUGRXEOHJDQJW\SHVDQGZLWKDQLQOLQHFRQQHFWRUVHWXSWR$ Ř'RXEOHJDQJUHFHSWDFOHSURYLGHGZLWKSUHVWULSSHGOHDGV Ř,QWHUPDWHDEOHZLWKRWKHUEUDQGV ,QGXVWULDO Wet Locations Corrosive Areas 2, 4, 5 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 1, 10 7, 8, 9 2, 4, 5, 6, 9, 10 1, 2, 4, 5, 7*, 8 2, 4, 5 * On enclosed rigs. 15