Input/Output Modules Features That Make a Difference: • Provides cost-effective expansion of input and output capacity • Compatible with full range of Software House iSTAR and apC access control panels • Locate modules up to 1,220 m (4,000 ft) away from controllers using flexible twowire RS-485 RM bus • Reduces length of sensor and control wiring to save installation costs • I8 provides eight Class A supervised inputs • R8 provides eight Form C relay outputs • I8-CSI, configurable supervised input model, allows use of existing input wiring without changing end-of-line (EOL) resistors • Three status LEDs per input (red/yellow/ green) and one per output enable quick diagnostics and troubleshooting • Small, modular size requires minimal panel space • Dedicated tamper input included on each module • Optional UL-listed enclosure available www.swhouse.com The Software House I8, R8, and I8-CSI modules provide a flexible, cost-effective means to expand the input and output functionality of any iSTAR or apC access controller. Common applications include alarm monitoring and control and elevator control. The I8 input module provides eight Class A supervised inputs. Three LEDs per input help the installer commission and troubleshoot each input circuit – red if the input is in alarm, green for normal, and yellow for a supervision error. LEDs may be turned off via a DIP switch setting. The I8-CSI module enhances the functionality of the standard I8 module by supporting numerous supervised circuit types and EOL resistance values. This allows the I8-CSI to accommodate existing field wiring without changing EOL resistors. More than 20 different circuit types are supported. The circuit type is selected via a bank of DIP switches and applies to all eight inputs on the I8-CSI. The R8 output module provides eight Form C dry contact relay outputs. A red status LED per output shows the state of the relay. All modules feature a dedicated input for an external cabinet tamper switch and mount easily in the Software House RM-CAN or RM-DCM-CAN enclosure. The modules communicate with iSTAR or apC controllers via the two-wire RM bus that allows total wiring distances of up to 1,220 m (4,000 ft). Up to eight I8s and eight R8s can be connected to each apC, iSTAR eX, and iSTAR Pro eight-reader model; up to 16 of each module can be connected to the iSTAR Pro 16-reader model. The modules are fully compatible with both C•CURE 800/8000 and C•CURE 9000. Specifications General Dimensions (H x W) . . . . . . . . Environmental . . . . . . . . . . . . . Power Input Voltage . . . . . . . . Tamper . . . . . . . . . . . . . . . . . . Weight . . . . . . . . . . . . . . . . . . Regulatory . . . . . . . . . . . . . . . 11.0 x 15.0 cm (4.3 x 5.9 in) 0° to 50° C (32° to 122° F); 5 to 85% relative humidity, non-condensing 12 VDC +/- 10% Dedicated input for external tamper switch 0.23 kg (8 oz) UL 294, UL 1076, FCC Part A, CE, EN 50133, RoHS I8 Input Module Power Requirements . . . . . . . Inputs . . . . . . . . . . . . . . . . . . . LEDs per Input . . . . . . . . . . . . 180 mA @ 12 VDC Eight Class A supervised Red (alarm), green (normal), yellow (supervision error) R8 Output Module Power Requirements . . . . . . . Outputs . . . . . . . . . . . . . . . . . LED Per Output . . . . . . . . . . . Relay Contact Ratings . . . . . . 45 mA @ 12 VDC plus 32 mA per active relay Eight Form C dry contact relays Red (relay active) 30 VDC, 2.0 A resistive 30 VDC, 1.0 A inductive 125 VAC, 0.4 A Optional Metal Enclosures with Tamper Switch RM-DCM-CAN Dimensions . . . . . . . . . . . . . 356 x 305 x 89 mm (14 x 12 x 3.5 in) Capacity . . . . . . . . . . . . . . . Up to four input or output modules RM-CAN Dimensions . . . . . . . . . . . . . 210 x 184 x 83 mm (8.25 x 7.25 x 3.25 in) Capacity . . . . . . . . . . . . . . . One input or output module I8-CSI Input Module Power Requirements . . . . . . . Inputs . . . . . . . . . . . . . . . . . . . LEDs per Input . . . . . . . . . . . . Ordering Information 180 mA @ 12 VDC Eight Class A supervised, configurable via DIP switch Red (alarm), green (normal), yellow (supervision error) Circuits Supported . . . . . . . . . Single resistor: 1K, 5K, 10K Double resistor: 1K, 5K, 10K, 1K/2K, 6.8K/18K, 200/10K Unsupervised: NO, NC Model Numbers Description AS0073-000 I8 input module AS0073-CSI I8-CSI input module AS0074-000 R8 output module RM-DCM-CAN Large metal enclosure with tamper switch RM-CAN Small metal enclosure with tamper switch Wiring Summary Signal From To Belden # Gauge # of Pairs Shielded Maximum Length Comm (two-wire RS-485) apC/iSTAR I8/R8 9841* 24 1 Yes 1,220 m (4,000 ft) Power apC/iSTAR I8/R8 9841* 24 1 No Based on voltage drop Control Point R8 Strike, Siren, etc. 8442/8461 18 1 No Based on voltage drop Supervised Input I8 REX or Door Contact 8442/8461 22/18 1 No 610 m (2,000 ft) 1 ON S3 P7 1 DS26 S3 1 DS22 DS7 U3 ING Y1 DS6 DS21 DS20 DS5 FOR SWH STD 1K DUAL S2:3-4, S3:1-4 = OFF SEE QUICKSTART DOC FOR OTHER SETTINGS CYCLE POWER AFTER SETTING P3 P6 1 DS19 "WARNING Damage may result from incorrectly wiring power terminals, input and output lines, and central-supervising station lines. Check all connections before powering the unit." DS8 INF DS17 S2 S2 P5 1 P4 3 4 DS9 DS18 2 DS10 INE DS16 DS15 DS12 SW1 DS11 ASSEMBLED IN USA C 1 ON 1 DS13 COPYRIGHT 2007 TYCO SOFTWARE HOUSE® 18–CSI BOARD 0312–5008–01 Rev. Input Rating P9 12VDC 125mA DS14 Refer to Quick Start Installation Guide, P/N UM-218, Rev B0, July 2008 Note: Control, supervised, and unsupervised input cables must be shielded for FCC Class B operation. Approvals Readers INH DS24 DS23 S1 P2 P8 DS25 4 3 4 3 2 2 GND S1 DS27 I8-CSI Input Module Configuration I8 Input Module Configuration P10 P5 1 2 3 1 -D 1 Related Products iSTAR Controllers SW1 NOTE: All mounting holes are 1/8" dia. Max. component height 1/2". (*) For plenum or underground applications, use Belden 89182 for one pair 22 AWG, 100 ohm 12.95 pf/ft. C•CURE 9000 2 3 4 56 1 7 8 0 F 9 E DC B A +D DS3 IND 3 2 1 P6 1 2 3 +12V DS2 1 P4 TAMPER INPUT P7 1 2 3 GND DS4 INC 3 2 1 1 2 3 1 P3 R8 OUTPUT MODULE AS-0074-000 REV.A SOFTWARE HOUSE MADE IN USA NO NC C NO NC C NO NC C NO NC C TS DS1 S1-1 ON = LED Power S1-2 ON = Disable Tamper S1-3 ON = Not Used S1-4 ON = 485 Termination 1 1 P1 INB 3 2 1 W1 P8 NO P2 C NC NO C NC NO C NC NO C NC NO P9 1 3 2 1 1 2 3 4 P9 P1 INA R8 Output Module Configuration Wiring Configuration Diagram www.swhouse.com © 2014 Tyco Security Products. All Rights Reserved. SH0146-DS-201410-R01-LT-EN Tyco and the product names listed above are marks and/or registered marks. Unauthorized use is strictly prohibited. Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your sales representative. Pb Pb-Free