544315 Function generator Design The function generator consists of a micro controller circuit, a selector switch, LCD display, pushbuttons, signal inputs, signal outputs and two bus bars for the power supply. The electrical connections for operating voltage, signal inputs and outputs are in the form of 4mm safety plugs. The unit is mounted either in the mounting frame or on the profile plate using four plug-in adapters. © Festo Didactic GmbH & Co. KG, 01/2008 Subject to change 1/6 544315 Function generator 2 1 3 EduTrainer® 11 24V 24V Pulse Pulse/s t0 t1 t2 t3 Pulse width out Frequency out START/UP 10 9 STOP RESET/DOWN 4 S1 8 S2 OUT 5 7 S3 6 0V 1 2 3 4 5 6 7 8 9 10 11 Function 2/6 0V Selector switch STOP pushbutton LCD display RESET/DOWN pushbutton and socket Frequency output - FREQUENCY OUT Voltage supply 0V DC START/STOP sockets for time measurement 3 START/STOP sockets for time measurement 2, input socket for pulse and frequency measurement START/STOP sockets for time measurement 1 START/UP pushbutton Voltage supply +24 V DC The function generator is equipped with an LCD display for the display of the set mode of operation and current measured values. The language shown on the display can be switched by simultaneously pressing the START and STOP pushbuttons when switching on. Subject to change © Festo Didactic GmbH & Co. KG, 01/2008 544315 Function generator The following five modes of operation are available via the function generator: 1. 2. 3. 4. 5. Impulse counting Frequency measurement Time measurement Square-wave signal output Voltage output Input pulse S2 Input frequency S2 Output OUT Output OUT Pulse Pulse/s t0, t1, t2, t3 Frequency out Pulse width out The modes of operation are set via a selector switch (hex switch). The function generator enables the counting of the proximity sensor output pulses. The time gap between two successive pulses can be determined via a START/STOP circuit. Examples Counting process The selector switch is set to the "Pulse" setting. To count objects, the output of a proximity sensor can be connected to socket S2. The counting process can be started, stopped or reset to “000” via the pushbuttons or proximity sensor connected to the S1 series sockets. You should make sure that the proximity sensor is connected to the same reference potential (0V connections) as that of the timer. Frequency measurement The selector switch is set to the "Pulse/s" setting. If speeds are to be measured using a proximity sensor (via perforated disks or similar), the speed can be determined with the help of the counter, whereby the switch output of the proximity sensor must be connected to socket S2. The displayed value can be easily converted into the corresponding speed rpm-1. The speed V is obtained as followed: U= −1 fs 60 • min Im p. / s n fs = Displayed pulse frequency (unit of Imp./s) n = A number of actuations per revolution © Festo Didactic GmbH & Co. KG, 01/2008 Subject to change 3/6 544315 Function generator Time measurements The selector switch is set to the settings "t0, t1, t2, t3". t0: The function generator operates in the same way as a manually operated stop watch. The times can be measured with the help of the START and STOP pushbuttons. t1, t2, t3: 3 times can be measured simultaneously. The currently displayed time can be selected via the selector switch. The input sockets S1 measure the time t1, the input sockets S2 measure the time t2 and the input sockets S3 measure the time t3. The times are stored until cancelled via the RESET socket or RESET pushbutton. Frequency output The selector switch is set to the "frequency out" setting. The output socket OUT supplies a square-wave voltage with 24 V DC level and a maximum current of 2A. The frequency range is 0.01 to 200Hz. The frequency is set via the START/UP and RESET/DOWN pushbuttons. Once set, the frequency last set is output. Voltage output The selector switch is set to the "Pulse width out" setting. The output socket OUT supplies an output voltage of 0 to 24 V DC and a maximum current of 2A. The voltage is set via the START/UP and RESET/DOWN pushbuttons. One switched on, the voltage last set is output. 4/6 Subject to change © Festo Didactic GmbH & Co. KG, 01/2008 544315 Function generator Note You have selected an output function of the function generator (frequency or voltage output) and set a value. You would now like to select an input function (counting processes, frequency measurement or time measurement). In order to do so, you must not turn the selector switch beyond the second output function as the set output value would thus not be retained. Pulse Pulse/s Pulse t0 t1 t2 t3 Pulse/s Pulse width out Frequency out © Festo Didactic GmbH & Co. KG, 01/2008 t0 t1 t2 t3 Pulse width out Frequency out Subject to change 5/6 544315 Function generator Technical data Electrics Operating voltage 24 V DC Input signal voltage + 15 – + 28 V DC Time measurementg Range Frequency measurement Range 0000 – 9999 ms 0.1 – 1000 Hz Frequency output Output voltage 24 V Output current Frequency range Max. 2 A 0.01 – 200 Hz Pulse width modulated output Output voltage Output current 0 – 24 V DC max. 2A Accuracy Frequency output Internal one-second cycle 6/6 ±3% ±3% Materials Aluminium (front plate) Polymer (housing) Weight 0.48 kg Connection for 4 mm safety plug Subject to change © Festo Didactic GmbH & Co. KG, 01/2008