07 COM 30V MAX 05 Functions AUTO OFF OFF MFD HZ MFD °F °C Voltage AC (VAC) (50Hz-500Hz) 09 VDC HZ Use NCV to check 24VAC from a thermostat or live voltage up to 600VAC. Always test a known live source before using. A segment graph and RED LED will display the presence of voltage. Audible beep increases from intermittent to continuous as intensity of field (EF) increases. AC Voltage Detection Range: 24VAC to 600VAC (50-60Hz) Test power lines (120, 220, 480), test 24V going to controls, and test for transformer failure. Ranges: 500mV, 5V, 50V, 500V, 600V Resolution: 0.1mV Accuracy: ±(1.2% + 8) 500mV range (50-60Hz) ±(1.2%+8), 5V, 50V, 500V; ±(1.5% + 8) 600V range True RMS: model SC640 only Crest factor: ≤ 3 Audio/Visual Hi-V indicator: >30VAC/VDC Input impedance: >100MΩ (500mV), 10MΩ (5V), 9.1MΩ (50V-600V) 10 µADC % V 30 X MA OFF M CO E YP K-T TO AU ld Ho 0 64 S RM SC UE TR DC µA e ng Ra SH RU IN t Selec HZ 50AAC VAC HZ 400 AAC VAC HZ % NCV Unplug Leads and Slide TEMP Switch to the Right VDC OFF % µADC °F °C °F °C Non Contact Voltage (NCV) COM VDC V COM 30V MAX TYPE K 0 40 AC Plug any Type K thermocouple directly into the meter to measure temperature. Cold junction is located inside the meter and allows for extremely accurate measurements even in rapidly changing ambient temperatures (going from rooftop to freezer). No adapter is required. Range: -30°F to 932°F, (-35°C to 500°C) Resolution: 0.1° Accuracy: ±(1°F)* 32°F to 120°F, ±(1°C) 0°C to 49°C ±(1%+2°F) 32°F to 572°F, ±(1%+1°C) 0°C to 300°C ±(2%+6°F) -30°F to 32°F, ±(2%+3°C) -35°C to 0°C ±(2%+6°F) 572°F to 932°F, ±(2%+3°C) 300°C to 500°C Sensor type: Type K thermocouple *After field calibration Overload protection: 30 VDC or 30VAC rms TYPE K HZ 400 AAC VAC VAC NCV 30V MAX VAC Temperature (°F/°C) AUTO OFF AUTO OFF HZ 50AAC HZAC HZ A AAC 30V MAX COM 50 TYPE K Please operate the instrument following all instructions of the operator's manual to avoid impairing the safety of the product. 08 Press to freeze the display. Hold 30V MAX 04 TRUE RMS SC640 TRUE RMS AUTO OFF Press to manually select a range. AUTO OFF COM 30V MAX Hold Hold TYPE K Range SC640 CAT III 600VIII CAT 600V AUTO OFF OFF Backlight: 60 second duration with auto-off. Blue color. SC640 only. Overrange: (OL) or (-OL) is displayed Measurement rate: 3.3 times per second, nominal Zero: Automatic Operating environment: 32°F to 122°F (0°C to 50°C) at <70% relative humidity Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed) Accuracy: Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH Temperature coefficient: 0.1 x (specified accuracy) per °C [0°C to 19°C (32°F to 66°F), 28°C to 50° C (82°F to 122°F)] APO (Auto Power Off): Approx. 30 minutes Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 Battery life: 200 hours typical alkaline (SC620); 100 hours typical alkaline (SC640) Low battery indication: Battery icon blinks and "LO.bt" is displayed when the battery voltage drops below the operating level Dimensions: 287.5mm(H) x 79.5mm(W) x 50.0mm(D) Weight: Approx. 450g including battery Altitude: Up to 6562 ft (2000m) Overload protection: 600 VDC or 600VAC rms unless otherwise stated Test leads: Use UL listed test leads that comply to UL61010-031 rated CATIII 600V or above. Included test leads are gold-plated and have removeable safety caps. WARNINGS ! DISCONNECT AND UNPLUG TEST LEADS before opening case. TEST NCV FUNCTION ON KNOWN LIVE WIRE before using. DO NOT APPLY VOLTAGE greater than 30VAC or 60VDC to the thermocouple or the jacks when the rotary dial is on °F°C. (Use only Type K thermocouples) DO NOT APPLY VOLTAGE TO THE JACKS when the rotary dial is on microamps. Even low voltages can cause a current overload and potentially harm the meter. µADC elect FD M Never ground yourself when taking electrical measurements. Do not touch exposed metal pipes, outlets, fixtures, etc., which might be at ground potential, while taking measurements. Keep your body isolated from ground by using dry clothing, rubber shoes, rubber mats, or any approved insulating material. Disconnect the test leads before opening the case. Inspect the test leads for damage to the insulation or exposed wire. Replace if suspect. Keep your fingers behind the finger guards on the probes while taking measurements. When disconnecting from a circuit, disconnect the“RED”lead first, then the common“BLACK” lead. Use one handed testing when possible. Work with others. Turn off power to the circuit under test before cutting, unsoldering, or breaking the circuit. Do not measure resistance (ohms) when circuit is powered. Isolate load by disconnecting from circuit. Disconnect the meter from circuit before turning any inductor off, including motors, transformers, and solenoids. High voltage transients can damage the meter beyond repair. Z °F °C Specifications Display: 5000 count dual display Do not use during electrical storms. Do not apply more than rated voltages between input and ground. Isolate capacitors from system and discharge them safely before testing. Temperature switch prevents leaving thermocouple plugged in while measuring voltage. When measuring high frequency AC current, do not exceed the rated 400AAC of the clamp. Failure to adhere may cause the clamp to heat up dangerously. All voltage tests: All voltage ranges will withstand up to 600V. Do not apply more than 600VDC or AC rms. Symbols used: Caution, risk of electric shock ! Caution, refer to manual. Ground Double insulation DC DC INRUSH TYPE KTRUE RMS 03 DC Z NCV Safety Information TRUE RMS Z 400 AC Hold AC COM 02 K-TYPE MAX TYPE K 01 AC SC640 COM 30V MAX SC640 Z 50 AC Range CATIII 600V, class II and pollution degree 2 indoor use comply with CE, RoHS compliant. CATIII: Is for measurements performed in the building installation. AUTO OFF TYPE K Se lec t WEEE Hold HZ 400 AAC VAC VAC 30V RMS AUTO TRUE OFF TEMP K-TYPE MAX OFF H MFD Press Vto illuminate backlight (SC640). TRUE RMS AUTO OFF A TEMP 30V H K-TYPE V H TRUE RMSMAXAUTO OFFCAT III A % 30V V TEMP K-TYPE600V °F µA MAX 30V CAT III SC640 V Press to activate inrush MAX current °C K-TYPE TEMP 600V H TEMP CAT III % capture mode (SC640). S 600V NCV TRUE RMS Range C-Tick (N22675) Range Se lec t Hold TRUE RMS SC640 Z 50 AC µADC °F °C % Range VDC Se le HZ ct INRUSH Se lec t MFD µADC µADC % °F °C INRUSH µADC VDC °F °C VDC HZ °F °C NCV HZ VDC MFD MFD HZ 50AAC VAC HZ 400 AAC VAC HZ HZ 50AAC VAC HZ 400AAC VAC EN61010-1 EN61010-2-032 EN61010-2-033 EMC EN61326-1 HZ 50AAC VAC HZ 400 AAC VAC NCV HZ 50AAC VAC HZ 400 AAC VAC INRUSH OFF NCV INRUSH Models SC640 SC620 UL 61010-1, Third Edition Auto Power Off Enabled High Voltage Warning (>30VAC/VDC) Manual Range (RNG) Mode SEL NCV Data Hold Mode SEL Inrush Amps Mode (SC640) MFD VDC SEL Continuity Test SEL HZ % SEL Diode TestOFF TRUE RMS AUTO TRUE RMS AUTO OFFOFF TRUE AUTO °F µADC 30V RMS Frequency Test (hertz) 30VMAX °C K-TYPE 30V K-TYPE MAX K-TYPE MAXOFF Resistance Test (ohms) OFF TEMP TRUE RMS AUTO TRUE RMSOFF AUTO TEMP TEMP Capacitance Test (farads) 30V RMS TRUE RMS30VAUTO AUTO OFFK-TYPE TRUE OFF K-TYPE MAX CAT IIICycle Test (percentage) MAX Rotate dial to the function you want to use. Duty CAT III 30VTEMP CAT III TRUE AUTO OFF 30V TRUE RMS AUTORMS OFF 600V TEMP 600V K-TYPE K-TYPE MAX 600V Unit (10−6, one millionth) MAX % Micro OFF TEMP 30V TEMP 30V K-TYPE K-TYPE MAX CAT IIIMAX CAT III Milli Unit (10−3, one thousandth) TEMP TEMP 600V 600V CAT III CAT III KiloOFF Unit (103, one thousand) Press to cycle Amps AC and frequency600V 600V TRUE RMS AUTO % CAT III CAT III H OFF Mega Unit (106, one million) within VAC/AAC/Hz switch position. A TRUE RMS 30V AUTO 600VOFF 600V OFF MFD Display Controls INRUSH Certifications OPERATOR'S MANUAL The SC600 series are the new loaded clamp meters for the HVACR professional. Hang your SC600 series clamp meter to any metallic surface with the redesigned heavy-duty magnet and conveniently store your test leads when the job is done. See both voltage and amperage readings at the same time on the big dual LCD display, even in low light conditions using the bright blue backlight (backlight SC640 only). Easily see your amperage readings no matter how you clamp around a wire with the swivel head AAC clamp. Take more accurate VAC and AAC readings on variable frequency drives with True RMS sensing technology (SC640 only). Measure the starting amp draw of a compressor with Inrush current feature (SC640 only). Use the clamp jaw light to easily light up the test area. (SC640 only). Take measurements with one hand using theNCV single test lead holder for added safety. TestMFD leads come with removable gold plated tips to connect with Fieldpiece accessory heads. The SC600 series clamp meters are built toS el withstand the rigors of HVACR with high impact ect Range plastic and a display you can read in very hot or very cold environments. HZ 50AAC VAC HZ 400 AAC VAC Loaded Clamp Meters 06 Description 1.For electrical testing, connect test leads to "COM" and "+" jacks. 2. Rotate the dial to your desired measurement. 3. Connect to test points and read measurement. 4. For temperature testing, remove test leads, slide TEMP switch to the right and connect Type K thermocouple. OFF Quick Start NCV Fieldpiece O F Hz AAC SEL SEL SEL INRUSH F VAC AAC VDC NCV MFD °F°C% Hz %MFD°C F VAC V DC INRUSH NCV % Hz °F SEL NCV SEL °CHz INRUSH °F°C SEL SEL °F INRUSH Battery Life (replace 9V if blinking) INRUSH SEL SEL OFF HZ 400 AAC VAC MFD Duty Cycle (%) VDC HZ Duty cycle shows the % On Time of a 5V logic signal square wave. Ranges: 5%-95% (40Hz to 10kHz), 10%-90% (10kHz to 20kHz) Accuracy (5V logic): ±(2% + 10) Resolution: 0.1% PW: >10µs Overload Protection: 600VDC or 600VAC rms °F °C Capacitance (MFD) OFF Set to MFD to test motor start and run capacitors. Capacitors are one of the most failure prone components in a HVACR system. Disconnect from power and resistors between terminals. Discharge capacitor before testing. If dIS.C is displayed, capacitor is not discharged completely. Ranges: 5µF, 50µF, 500µF, 5mF Resolution: 1nF Accuracy: ±(3% + 15) 5µF, ±(3% + 5) 50µF to 500µF, ±(5% + 20) 5mF Overload Protection: 600VDC or 600VAC rms 11 NCV °F °C % µADC Discharge Cap First! HZ % °F °C µADC OFF NCV HZ 50AAC HZ VAC 400 AAC VAC Metric Ft/min MPH ºF M/s KM/hr ºC Metric Real time OFF VDC MFD HZ % AUTOOFF µADC °F °C AAV3 Select Range English Hold TRUE RMS SC640 AUTO OFF K-TYPE OFF NCV 30V MAX COM Visit www.fieldpiece.com to see all of the different accessory heads that Fieldpiece offers. 17 HZ 50AAC VAC HZ 400 AAC VAC HZ °F °C % µADC OFF HZ 50AAC VAC HZ 400 AAC VAC Auto Hold NCV Se lec t MFD VDC Hold °F °C TRUE RMS TYPE K Select M/m % COM TEMP 30V MAX CAT III 600V Se lec t Range CAT III 600V TRUE RMS Hold SC640 Battery Replacement AUTO OFF When your meter’s battery is low, the battery icon will appear empty and blink for 30 seconds. “LO.bt” will displayAUTOand meter will power off. OFF Turn dial to OFF position, disconnect test leads and remove the battery cover with magnet strap on the back of your meter. Remove old battery and replace with a standard 9V battery only. Be sure to re-insert the magnet strip before re-installing the battery cover. 30V MAX TYPE K COM C T1 TEMP CAL TYPE K B 30V MAX COM 18 19 30V MAX OFF K AUTO COM Hold TYPE RMS DC VDC 40 SC6 HZ % Inrush feature captures starting current of a compressor motor. Starting current can assist in diagnosing a motor before it fails. To activate Inrush feature 1. Turn selector switch to VAC/50AAC/Hz or VAC/400AAC/Hz 2. Press SELECT to show AAC on upper display. Press INRUSH, on right side of the meter, to activate. 3. Clamp meter around compressor start wire. Turn motor on. The starting current will hold on the upper display. 4. Hold INRUSH for 2 seconds to exit Inrush feature or press and release INRUSH to measure starting current again. Inrush measurement period: 100-milliseconds Minimum input: >2A on 50A range; >20A on 400A range ! Note: AAC through the clamp and voltage through the test leads can be measured simultaneously. However, if only AAC, Frequency (Hz), or Inrush is measured through the clamp, test leads and thermcouple must be unplugged from the meter. Call Fieldpiece Instruments for one-pricefix-all out-of-warranty service pricing. Send check or money order for the amount quoted. Send the meter freight prepaid to Fieldpiece Instruments. Send proof of date and location of purchase for in-warranty service. The meter will be repaired or replaced, at the option of Fieldpiece, and returned via least cost transportation. For international customers, warranty for products purchased outside of the U.S. should be handled through local distributors. This meter is warranted against defects in material or workmanship for one year from date of purchase. Fieldpiece will replace or repair the defective unit, at its option, subject to verification of the defect. This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument. Any implied warranties arising from the sale of a Fieldpiece product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. Fieldpiece shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim of such damage, expenses, or economic loss. State laws vary. The above limitations or exclusions may not apply to you. 30V MAX % µADC Obtaining Service Limited Warranty e Rang AUTO OFF TYPE K 15 Clean the exterior with a dry cloth. Do not use liquid. µADC TEMP COM % µADC Maintenance AAC VAC VDC NCV °F°C Press and hold for two seconds. Meter AUTO OFF will beep andSC640 HOLD will blink on LCD. After 6 seconds the measurement on screen will freeze automatically. Press to exit this mode. HZ Range VDC °F °C ge M/m VDCRan Select HZ 50AAC VAC HZ 400 AAC VAC HZ AAC VAC VDC NCV °F°C DO NOT SWITCH FROM J2 % µADC MFD HOLD VDC READ OFF INRUSH MFD LCD X 100 Air Velocity & Temperature Average English (16 sec) Head INRUSH NCV ON LO BATT MFD A HZ 50AAC VAC HZ 400 AAC VAC VDC NCV VDC HZ °F °C HZ °F °C SH INRU Inrush Current (SC640 only) MFD Auto power off or APO will automatcially turn off your meter after 30 minutes of inactivty. By default it is activated and APO will show on the display. To disable, turn meter off. Hold and SC240 power on the meter by turning the selector dial to any range. Release after the beep. APO will no longer displaySC240 over the battery icon. INRUSH HZ 400 AAC VAC VAC MFD Fieldpiece HOLD HZ 50AAC Fieldpiece MFD 1. Select the °F °C range. 2. Plug thermocouple to be calibrated into the Type K jack. 3. Unscrew A and B and remove the battery cover. 4. Stabilize a large cup of ice water. Stir the ice with the water until temperature stays at a stable value. 5. Immerse the thermocouple probe and let it stabilize. Keep stirring water to prevent thermocouple from direct contact with ice. 6. Use a small screwdriver to adjust calibration pot C below the battery as close to 32°F(0°C) as you would like. Note: J1-J2 switch is for autocalibration purposes only. Do not switch from J2. NCV HZ 50AAC HZ VAC 400 AAC VAC MFD % µADC 14 Auto Power Off For accuracies of ±1°F, calibrate thermocouple to a known temperature. A glass of stabilized ice water is very close to 32°F (0°C) and is usually very convenient but any known temperature can be used. Your new Swivel Clamp Meter is compatible with all Fieldpiece Accessory Heads. With Fieldpiece Accessory Heads, you can measure any available parameter, and read the measurement on your new meter's display in real-time. Just set the range to VDC and press the RANGE button until mV is displayed. Remove the probe tips of your test leads, and connect your accessory head (model AAV3 shown). OFF K-TYPE CAT III 600V Temp. Calibration OFF NCV K-TYPE TEMP TEMP Measure Hz on variable frequency drive motors. Turn dial to VAC/ AAC/Hz and press SELECT twice. Hz will show in upper display. Range: 10Hz to 400Hz Accuracy: ±(0.1% + 5) Minimum current range: > 5AAC Overload Protection: 400AAC Resolution: 0.1Hz HZ 50AAC VAC HZ 400 AAC VAC HZ Test diodes forIIIproper forward and reversed-biased functions. CAT Test current:600V 0.8mA (Approx.) Accuracy: ±(1.5% + 5) Open circuit volts: 3.2VDC typical Audible beep: <0.03V Visual Indicator: Green LED Overload 600VDC or 600VAC rms TRUE RMS Protection: AUTO OFF 30V 13MAX Frequency (Hz) Through Clamp VDC °F °C Diode Test ( ) VDC 12 OFF 30V MAX % µADC MFD Use the continuity feature to test if a circuit is open or closed. Use this feature to check fuses as well. A steady “beep” and green LED indicate you have continuity. Range: 500Ω Resolution: 0.1Ω Response time: 100ms AudibleRMS beep: <30Ω Overload TRUE AUTO OFF Protection: 600VDC or 600VAC rms HZ 50AAC VAC HZ 400 AAC VAC HZ OFF NCV Continuity SEL ( ) % µADC MFD Modular Expandability 16 HZ 50AAC VAC NCV °F °C Resistance (Ω) Frequency (Hz) Through Leads Check incoming voltages to ensure they are cycling at 60Hz. For frequency measurements on VFD equipment, use the amp clamp. Ranges: 500Hz, 5kHz, 50kHz, 500kHz, 1MHz Resolution: 0.1Hz Accuracy: ±(0.1% + 5) Sensitivity: 10Hz to 1MHz: >3.5Vrms PW: >1µs Duty Cycle Limits: >30% and <70% HZ TRUE °F °C % VDC MFD µA HZ µADC Test any isolated power line. Press SELECT on VAC/AAC/Hz position. Read AAC in upper display. True RMS on SC640 only. Ranges: 50A, 400A Resolution: 0.01A Crest factor: ≤ 3 Accuracy: ±(2.0% + 10) 50-60Hz Jaw Opening: 1.2in (30 mm) °F °C VDC NCV Amps AC (AAC) True RMS HZ 50AAC VAC HZ 400 AAC VAC e Rang MFD OFF HZ AC HZ 50A AC VAC 400A VAC NCV HZ 50AAC VAC HZ 400 AAC VAC Select OFF OFF Voltage DC (VDC) Microamps for flame rectifier diode test on a heater control. Connect leads between flame sensor probe and control module and turn heating unit on to read µA measurement. When the flame is on, there should be a measurable µADC signal, typically under 10µADC. Compare measurement to manufacturer’s specification to determine if replacement is necessary. Ranges: 500µA Resolution: 0.1µA Accuracy: ±(1.0% + 2) Volts burden: 1V Overload Protection: 600VDC or 600VAC rms MFD MicroAmps DC (µADC) NCV F AAC F VAC VDC MFD SC56 % NCV Hz °F°C Select VDC and measure DC voltages on circuit boards on more INRUSH advanced HVACR systems. Ranges: 500mV, 5V, 50V, 500V, 600V Resolution: 0.1mV Accuracy: ±(0.5% + 2) HOLD Input impedance: O Hz >100MΩ (500mV), 10MΩ (5V), F A AC 9.1MΩ (50V-600V) F VAC VDC MFD % NCV Hz °C °F Used for “ohming out” aSEL compressor motor. 0.1Ω resolution is INRUSH useful to test the resistance between the motor poles because the values are typically very low. Ranges: 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 50MΩ Resolution: 0.1Ω Overload Protection: 600VDC or 600VAC rms Accuracy: ±(1.0% + 5) 500Ω to 500kΩ, ±(1.5% + 5) 5MΩ, ±(3.0% + 5) 50MΩ www.fieldpiece.com © Fieldpiece Instruments, Inc 2014; v28 20