Tariff Description =========================================================================== 8536.10 FUSE LINKS, semiconductor and thyristor protection, voltage rating 800 V RMS, AC and 500 V DC Op. 03.08.1983 Dec. 06.12.1984 - TC 8430438 8536.10 FUSE LINKS, semiconductor and thyristor protection, voltage rating 1 550 V peak, 1 000 V RMS, AC and 700 V DC Op. 03.08.1983 Dec. 20.08.1984 - TC 8430439 8536.10 FUSE LINKS, semiconductor and thyristor protection, having ALL of the following: (a) current rating 20 A or less; (b) voltage rating 450 V peak, 240 V RMS, AC and 200 V DC Op. 03.08.1983 Dec. 21.03.1985 - TC 8433970 8536.10 FUSE LINKS, having a current rating of 0.25 A or greater but NOT exceeding 200.00 A, to British Defence Specifications DEF 63 A Op. 22.05.1984 Dec. 22.05.1984 - TC 8438399 8536.10 FUSES, blade terminal type, having a voltage rating NOT exceeding 32 V Op. 22.05.1984 Dec. 22.05.1984 - TC 8438455 8536.10 FUSE LINKS, semiconductor protection, having BOTH of the following: (a) dimensions NOT exceeding 10.3 mm x 38.1 mm; (b) current rating 1 A or greater but NOT exceeding 20 A Op. 06.03.1985 Dec. 06.05.1985 - TC 8530772 8536.10 FUSES AND FUSE HOLDERS, subminiature, plug in or pigtail type known as picofuses or microfuses, dimensions NOT exceeding 6 mm x 18 mm Op. 06.03.1985 Dec. 06.05.1985 - TC 8530773 8536.10 FUSES, motorcycle Op. 01.07.1985 Dec. 18.02.1986 - TC 8533599 8536.10 FUSE CARTRIDGES, glass tube, rated voltage less than 500 V, being EITHER of the following: (a) slow blow type NOT exceeding 200 mA; (b) fast acting type NOT exceeding 30 mA Op. 15.08.1985 Dec. 15.08.1985 - TC 8533840 8536.10 FUSE LINKS, having ALL of the following: (a) dimensions NOT exceeding 6.35 mm x 32.0 mm; (b) current rating NOT exceeding 50 A; (c) voltage rating NOT exceeding 250 V Op. 06.08.1987 Dec. 14.01.1988 - TC 8734467 8536.10 FUSE LINKS, having a current rating of 1 000 A or greater, but NOT including parts therefor Op. 01.01.1988 Dec. 01.01.1988 - TC 8804148 8536.10 FUSES, subminiature, plug-in or pigtail with mating fuse holders, body dimensions NOT exceeding 10 mm x 10 mm x 10 mm Op. 22.05.1989 Dec. 24.08.1989 - TC 8903315 8536.10.00 FUSE LINKS, having ALL of the following: (a) current rating NOT less than 2 A and NOT greater than 1 250 A; (b) breaking capacity of NOT less than 80 KA Op. 16.10.2007 Dec. 31.01.2008 - TC 0717642 8536.10.00 FUSE LINKS, semiconductor and thyristor protection, voltage rating 660 V - 1 000 V AC, to VDE 0636/23 specification with utilisation category gR or aR Op. 16.06.1994 Dec. 16.09.1994 - TC 9405193 Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8536.10.00 FUSES, HRC ferrule, incoming mains protection 440 V, rated 30 A to 100 A, breaking capacity 80 kA Op. 13.02.1995 Dec. 21.05.1995 - TC 9501767 8536.10.00 FUSES, HRC, voltage rating 660 V, current rating NOT less than 100 A and rupturing capacity NOT less than 80 kA Op. 11.09.1995 Dec. 08.12.1995 - TC 9510449 8536.10.00 FUSE LINKS, HRC, having ALL of the following: (a) voltage rating of 415 V or greater but NOT exceeding 600 V; (b) current rating of 2 A or greater but NOT exceeding 1 250 A; (c) breaking capacity of NOT less than 80 kA Op. 03.10.1995 Dec. 05.01.1996 - TC 9511051 8536.10.00 POWER SEMICONDUCTOR FUSES, rated voltage 660 V or 1 250 V, current rating of 10 A or greater but NOT exceeding 7 500 A Op. 03.10.1995 Dec. 05.01.1996 - TC 9511052 8536.10.00 FUSES, LAMP BATTERY, MINERS", 4V, 3A, encapsulated Op. 22.07.1998 Dec. 02.10.1998 - TC 9806508 8536.20 CIRCUIT-BREAKERS, DC, rated voltage exceeding 500 V and rated normal current exceeding 1 000 A Op. 11.08.1983 Dec. 02.12.1983 - TC 8333576 8536.20 OVER CURRENT PROTECTION DEVICES, having ALL of the following: (a) manually resettable; (b) trip free; (c) maximum current NOT exceeding 15 A; (d) maximum breaking capacity NOT exceeding 150 A; (e) tripping characteristic 137.5% within 2 h; (f) size NOT exceeding ANY of the dimensions 60 mm x 20 mm x 20 mm Op. 30.05.1985 Dec. 12.12.1985 - TC 8531177 8536.20.00 CIRCUIT BREAKERS, AC AND/OR DC, multiple pole, having BOTH of the following: (a) current rating NOT less than 400 A; (b) operating voltage NOT greater than 1 000 V Op. 27.11.2013 Dec. 03.03.2014 - TC 1339014 8536.20.00 CIRCUIT BREAKERS, DC, having BOTH of the following: (a) rated voltage NOT less than 600 V and NOT greater than 1 000 V; (b) rated current NOT greater than 125 A Op. 14.10.2011 Dec. 09.01.2012 - TC 1134597 8536.20.00 CIRCUIT BREAKERS, AC AND/OR DC, having ALL of the following: (a) not LESS than 2 poles and NOT exceeding 4 poles; (b) current rating NOT less than 125 A and NOT greater than 6 300 A; (c) operating voltage not LESS than 460 V and NOT greater than 750 V Op. 27.07.2011 Dec. 28.10.2011 - TC 1125309 8536.20.00 CIRCUIT BREAKERS, AC AND/OR DC, having ALL of the following: (a) current rating NOT greater than 400 A; (b) single OR multiple pole; (c) operating voltage NOT greater than 1 000 V AC Op. 30.06.2011 Dec. 26.09.2011 - TC 1121463 8536.20.00 CIRCUIT BREAKERS, RESIDUAL CURRENT AND OVERCURRENT PROTECTION, non DIN rail mounted Item 50 applies unless otherwise stated. Tariff Description =========================================================================== Op. 05.02.2009 Dec. 01.05.2009 - TC 0903883 8536.20.00 CIRCUIT BREAKERS, RESIDUAL CURRENT AND OVERCURRENT PROTECTION (RCBO), DIN rail mount Op. 05.09.2008 Dec. 28.11.2008 - TC 0829880 8536.20.00 CIRCUIT BREAKERS, industrial, hydraulic magnetic, conforming to Australian Standard AS 3111-1994 Op. 05.12.2008 Dec. 27.02.2009 - TC 0842822 8536.20.00 CIRCUIT BREAKERS FOR EQUIPMENT (CBE), thermal, having ALL of the following: (a) panel mounting; (b) either s-type, r-type or m-type to IEC 934; (c) current rating NOT exceeding 35 amps; (d) blade or screw terminals; (e) operating voltage rating NOT exceeding 250 V-AC, or 28 V DC; (f) minimum insulation value 2.5 kV (to IEC 664 and 664A); (g) approved by Lloyds register of shipping for use in commercial marine applications Op. 15.09.1994 Dec. 16.12.1994 - TC 9407619 8536.20.00 CIRCUIT BREAKERS, 3 and 4 pole incorporating an electronic 8-bit microprocessor based protection device which detects true R.M.S. (root mean squared) values of load currents, and having ALL of the following: (a) adjustable long time-delay trip (Ltd); (b) adjustable short time-delay trip (Std); (c) adjustable instantaneous trip (Inst); (d) Adjustable ground fault trip (Gft); (e) Adjustable pre-trip alarm (Pta); (f) adjustable rated current from 50% to 100% of the nominal rated current and adjustable in 15 steps Op. 16.09.1994 Dec. 16.12.1994 - TC 9407657 8536.20.00 CIRCUIT BREAKERS, AC, having ALL of the following: (a) NOT less than two poles and NOT exceeding six poles; (b) a current rating NOT less than 125 A and NOT exceeding 6 300 A; (c) a rated operational voltage of NOT less than 460 V and NOT exceeding 690 V Op. 22.05.1996 Dec. 23.08.1996 - TC 9607712 8536.20.00 CIRCUIT BREAKERS, THERMAL SENSING, width or diameter NOT exceeding 14 mm, fitted with connectors, but NOT including circuit breakers of the plug in type OR din rail mounting type Op. 05.06.1997 Dec. 12.09.1997 - TC 9705002 8536.20.00 CIRCUIT BREAKERS, thermal, magnetic, having ALL of the following: (a) single pole snap action mechanism; (b) push button reset; (c) blade terminals 6.3 mm wide; (d) plug in mounting; (e) current rating NOT exceeding 16 A; (f) maximum voltage rating 250 V AC OR 65 V DC; (g) maximum interrupting capacity 400 A; (h) overall dimensions NOT exceeding 72 mm x 50 mm x 11.5 mm Op. 11.08.1997 Dec. 08.12.1997 - TC 9706980 8536.20.00 PROTECTORS, THERMAL, bimetal disc, having BOTH of the following: (a) a cut off temperature of 60 degrees C, or greater but NOT exceeding 350 degrees C; (b) a current rating NOT exceeding 25 A Op. 27.10.1997 Dec. 09.01.1998 - TC 9709468 Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8536.20.00 PROTECTORS, THERMAL MOTOR, on-winding, having no external feedback path or controller Op. 27.10.1997 Dec. 13.03.1998 - TC 9709469 8536.30 ARRESTERS, surge, gaseous discharge, but NOT including those incorporated in an encapsulating compound Op. 18.08.1987 Dec. 18.08.1987 - TC 8734320 8536.30 PROTECTED SHUNT DIODE SAFETY BARRIERS, with a maximum working voltage of 35 V excluding those with maximum working voltage below 35 V Op. 06.07.1990 Dec. 19.12.1990 - TC 9006127 8536.30.00 TRIP UNITS, ELECTRONIC OR MAGNETIC OR THERMAL MAGNETIC, CIRCUIT BREAKER, POWER DISTRIBUTION OR MOTOR PROTECTION, multi-poles, having BOTH of the following: (a) frequency NOT exceeding 100 Hz; (b) NOT exceeding 500 amps Op. 03.12.2015 Dec. 07.03.2016 - TC 1543206 8536.30.00 ELECTRONIC TRIP UNITS, CIRCUIT BREAKER, POWER DISTRIBUTION, SHORT CIRCUIT PROTECTION, multi-poles, having BOTH of the following: (a) frequency NOT exceeding 100 Hz; (b) rating NOT less than 630 amps and NOT greater than 6 300 amps Op. 03.12.2015 Dec. 07.03.2016 - TC 1543205 8536.30.00 SURGE ARRESTER MODULES, single OR multi line, having BOTH of the following: (a) peak current normal mode being EITHER of the following: (i) 0.2 kA; (ii) 6.5 kA, (b) peak current common mode NOT less than 0.15 kA and NOT greater than 0.5 kA Op. 30.07.2015 Dec. 14.12.2015 - TC 1529895 8536.30.00 HOLDERS AND BASES, ELECTRICAL FUSE, complying with Australian Standard 60269.2.1-2005 (AS 60269.2.1-2005), being ANY of the following: (a) modular fuse holders; (b) ferrule fuse fittings having a voltage rating NOT greater than 690 V; (c) DIN fuse bases having a voltage rating NOT greater than 690 V; (d) fuse bases having a rating NOT less than 30 A and NOT greater than 600 A; (e) DC fuse fittings Op. 01.06.2010 Dec. 30.08.2010 - TC 1024524 8536.30.00 FUSE HOLDERS OR FUSE BASES, complying with Australian/New Zealand Standard AS/NZ 60269.2.1:2001, having ALL of the following: (a) rated voltage NOT greater than 1 000 V; (b) insulating shrouds; (c) rail mounting clips Op. 26.02.2010 Dec. 21.05.2010 - TC 1010227 8536.30.00 FUSE HOLDERS AND FUSE BASES, ELECTRICAL, complying with Australian Standard AS 60269.2.1-2005 Part 2.1 Section II, having ALL of the following: (a) rated AC/DC voltage NOT greater than 660 V; (b) shrouded phenolic thermo setting insulation; Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8536.30.00 (c) current rating NOT greater than 400 A Op. 17.11.2009 Dec. 29.04.2010 - TC 0943395 DECOUPLER, SOLID STATE Op. 17.12.2007 - TC 0721703 Dec. 07.03.2008 8536.30.00 OVERCURRENT PROTECTION DEVICES, solid state, cross-linked conductive polymer, latching, remotely resettable Op. 26.12.1994 Dec. 24.03.1995 - TC 9500424 8536.30.00 BARRIERS, SAFETY, designed in accordance with AS2380.1 and AS2380.7, being ANY of the following: (a) signal interfaces; (b) solenoid/alarm drivers; (c) signal isolators; (d) isolating devices Op. 26.09.1995 Dec. 02.01.1996 - TC 9510893 8536.30.00 CUT-OFFS, THERMAL, DOMESTIC APPLIANCE, non-resettable, having BOTH of the following: (a) a cut off temperature of 60 degrees C OR greater but NOT exceeding 350 degrees C (b) a current rating NOT exceeding 25 A Op. 19.12.1997 Dec. 13.03.1998 - TC 9711212 8536.30.00 SURGE SUPPRESSORS, having BOTH of the following: (a) peak voltage of +/- 6 000 volts; (b) breakover voltage of 8 to 260 volts Op. 21.12.1998 Dec. 16.03.1999 - TC 9810972 8536.30.00 SURGE SUPPRESSORS, having ALL of the following: (a) output voltage of 230 volts AC +/- 5%; (b) load capacity (volt-amps) of up to 1 250 watts Op. 21.12.1998 Dec. 16.03.1999 - TC 9810973 8536.30.00 REACTORS, SURGE SUPPRESSION, AC MOTOR Op. 11.06.2002 Dec. 23.08.2002 - TC 0204939 8536.41 RELAYS, being EITHER of the following: (a) assembly of two 12 V, 30 A single pole relays in a common enclosure; (b) assembly of two 24 V, 20 A single pole relays in a common enclosure Op. 02.07.1984 Dec. 22.01.1985 - TC 8432127 8536.41 RELAYS, coaxial Op. 22.05.1984 8536.41 8536.41 Dec. 22.05.1984 - TC 8438500 RELAYS, thermostatic delay Op. 22.05.1984 Dec. 22.05.1984 - TC 8438503 RELAYS, vacuum, hermetically sealed Op. 22.05.1984 Dec. 22.05.1984 - TC 8438508 8536.41 RELAYS, magnetically polarised (but NOT including sockets therefor), being EITHER of the following: (a) relays having EITHER of the following: (i) a sensitivity NOT exceeding 75 A turns operating at normal voltage; (ii) body dimensions NOT exceeding 30 mm x 30 mm x 20 mm; (b) relays of the carpenter type Op. 22.05.1984 Dec. 22.05.1984 - TC 8438509 8536.41 RELAYS, mercury wetted, contact type Item 50 applies unless otherwise stated. Tariff Description =========================================================================== Op. 22.05.1984 Dec. 22.05.1984 - TC 8438513 8536.41 RELAYS, thermal overload, having ALL of the following characteristics: (a) trip time NOT exceeding 5 s at 6 times full load current; (b) manual reset; (c) maximum current 50 A Op. 22.05.1984 Dec. 22.05.1984 - TC 8438526 8536.41 RELAYS, motorcycle Op. 01.07.1985 Dec. 18.02.1986 - TC 8533600 8536.41 RELAYS, cradle, having ALL of the following: (a) maximum switching current NOT exceeding 5 A (AC or DC); (b) switching voltage NOT exceeding 250 V (AC or DC); (c) body dimensions NOT exceeding 31 mm x 36 mm x 19 mm Op. 22.05.1984 Dec. 21.10.1985 - TC 8534635 8536.41 CONTACTORS, having BOTH of the following: (a) normally closed main poles; (b) DC rated current 9 A or greater Op. 01.01.1988 Dec. 01.01.1988 - TC 8804978 8536.41 RELAYS, having a continuous contact rating of NOT less than 3 A and body dimensions NOT exceeding 40 mm x 30 mm x 27 mm Op. 15.11.1989 Dec. 20.09.1990 - TC 8909066 8536.41.00 RELAYS, having an operating voltage NOT exceeding 48 volts, having ANY of the following: (a) spring loaded terminals; (b) plug-in screw terminals; (c) wire connected terminals Op. 04.04.2008 Dec. 27.07.2011 - TC 1122473 8536.41.00 RELAYS, reed, encapsulated, PCB mounting Op. 08.01.1993 Dec. 13.04.1993 - TC 9300931 RELAYS, distance, having ALL of the following: (a) NOT less than 3 zones of measurement; (b) switch on to fault logic Op. 19.08.1993 Dec. 26.11.1993 - TC 9307491 8536.41.00 8536.41.00 RELAYS, solid state, having a voltage range NOT exceeding 60 V AC or 60 V DC, but Not including protective monitoring relays Op. 08.10.1993 Dec. 18.03.1994 - TC 9310886 8536.41.00 RELAYS, complying with British Railways Board specifications BR930 to BR968, NOT including bases or plugboards Op. 23.05.1995 Dec. 01.09.1995 - TC 9505703 8536.41.00 RELAYS, printed circuit mounted, OTHER THAN reed relays, being EITHER of the following: (a) height NOT exceeding 24 mm; (b) height NOT exceeding 35 mm and having a continuous contact rating NOT less than 8 A AC Op. 25.09.1996 Dec. 06.12.1996 - TC 9611023 8536.41.00 RELAYS, low profile, OTHER THAN reed relays, being EITHER of the following: (a) height NOT exceeding 21.24 mm; (b) height NOT exceeding 35 mm and having a continuous current rating NOT less than 8 A AC Op. 02.10.1996 Dec. 13.12.1996 - TC 9611237 RELAYS, PRINTED CIRCUIT BOARD, having a height NOT exceeding 30.0 mm 8536.41.00 Item 50 applies unless otherwise stated. Tariff Description =========================================================================== Op. 26.06.1998 Dec. 18.09.1998 - TC 9805587 8536.49 CONTACTORS, AC, having a rated thermal current (ITH) NOT less than than 270 A For the purposes of TC 8333302 thermal current rating is to be in compliance with AS1029 or equivalent specifications Op. 01.07.1983 Dec. 01.07.1983 - TC 8333302 8536.49 CONTACTORS, DC, air break, rated operational current 1 500 A or greater Op. 13.03.1984 Dec. 13.03.1984 - TC 8430992 8536.49 RELAYS, power, photo-isolated, solid-state Op. 22.05.1984 Dec. 22.05.1984 - TC 8438517 CONTACTORS, having BOTH of the following: (a) normally closed main poles; (b) DC rated current 9 A or greater Op. 26.06.1985 Dec. 25.10.1985 - TC 8532678 8536.49 8536.49 RELAYS, multipole, enclosed, capable of ALL of the following: (a) continuous operation over the temperature range - 40 degrees C to + 80 degrees C (both inclusive); (b) 8 h operation without failure at + 100 degrees C; (c) relay contacts shall NOT arc when the mounted relays are subjected to the following vibration displacements and frequencies: (i) 4.83 mm at a frequency of 15 Hz; (ii) 2.54 mm at a frequency of 20 Hz; (iii) 0.51 mm at a frequency of 37 Hz Op. 28.06.1986 Dec. 14.11.1986 - TC 8533360 8536.49 RELAYS, power appliance, 15 A, having EITHER 2 contacts or 3 contacts Op. 01.01.1988 Dec. 01.01.1988 - TC 8633636 8536.49 RELAYS, having a continuous contact rating of NOT less than 3 A and body dimensions NOT exceeding 40 mm x 30 mm x 25 mm Op. 01.01.1988 Dec. 01.01.1988 - TC 8633665 8536.49 RELAYS, vacuum, hermetically sealed Op. 01.01.1988 Dec. 01.01.1988 - TC 8633667 RELAYS, thermostatic delay Op. 01.01.1988 Dec. 01.01.1988 - TC 8633668 8536.49 8536.49 RELAYS, thermal overload, having ALL of the following characteristics: (a) trip time NOT exceeding 5 s at 6 times full load current; (b) manual reset; (c) maximum current 50 A Op. 01.01.1988 Dec. 01.01.1988 - TC 8633669 8536.49 RELAYS, coaxial, coil ratings NOT exceeding 250 V Op. 01.01.1988 Dec. 01.01.1988 - TC 8732152 8536.49 RELAYS, thermal replica, with heating and cooling constants and negative phase sequence compensation Op. 28.02.1989 Dec. 30.06.1989 - TC 8901545 8536.49 RELAYS, having ALL of the following: (a) one, two or three contacts; (b) maximum continuous contact current rating of NOT less than 15 A; Item 50 applies unless otherwise stated. Tariff Description =========================================================================== (c) maximum contact voltage rating of NOT less than 380 V; (d) maximum switched power rating of NOT less than 4 000 VA Op. 17.08.1989 Dec. 13.02.1991 - TC 8906734 8536.49.00 SWITCHES, static transfer, having ALL of the following: (a) three phase; (b) nominal output voltage NOT less than 120 V and NOT greater than 400 V; (c) output power capacity NOT less than 80 kW and NOT greater than 500 kW Op. 30.07.2015 Dec. 19.10.2015 - TC 1529893 8536.49.00 CONTACTORS, single OR multi-pole, for a voltage NOT exceeding 1000 V Op. 09.04.2013 Dec. 08.07.2013 - TC 1312158 8536.49.00 RELAYS, having an operating voltage NOT exceeding 250 volts, having ANY of the following: (a) spring loaded terminals; (b) plug-in screw terminals; (c) wire connected terminals Op. 04.04.2008 Dec. 27.07.2011 - TC 1122469 8536.49.00 RELAYS, OVERLOAD PROTECTION, solid state, with or without reset, having multiple trip classes Op. 05.02.2009 Dec. 01.05.2009 - TC 0903767 8536.49.00 RELAYS,THERMAL OVERLOAD, non solid state, with or without reset Op. 05.02.2009 Dec. 01.05.2009 - TC 0903764 8536.49.00 RELAYS, POWER TRANSFORMER, oil tight to transformer oil at 100 degrees centigrade and 1 bar Op. 17.01.2008 Dec. 28.03.2008 - TC 0800990 8536.49.00 RELAYS, distance, having ALL of the following: (a) NOT less than 3 zones of measurement; (b) switch on to fault logic Op. 18.08.1993 Dec. 26.11.1993 - TC 9307452 8536.49.00 RELAYS, directional, with an operating characteristic limited to +/- 90 degrees of the relay characteristic angle, but NOT including distance relays Op. 18.08.1993 Dec. 26.11.1993 - TC 9307453 8536.49.00 RELAYS, solid state, having an operating voltage NOT exceeding 600 V AC or 300 V DC, but NOT including protective monitoring relays Op. 08.10.1993 Dec. 10.06.1994 - TC 9320885 8536.49.00 RELAY SYSTEMS, low impedance busbar protection, comprising ANY of the goods listed in Table A imported with one or more of the goods listed in Table B: Table A (a) zone measuring modules; (b) alarm modules; (c) test modules; (d) power supply Table B (a) bus coupler modules; (b) feeder breaker modules; (c) bus section breaker modules; (d) bus selection isolator modules; (e) bus section isolator modules; (f) buswire access modules Item 50 applies unless otherwise stated. Tariff Description =========================================================================== Op. 15.02.1994 Dec. 27.05.1994 - TC 9402278 8536.49.00 RELAYS, GENERATOR PROTECTION, digital, capable of providing acquisition and evaluation of measured values and having ALL of the following capabilities: (a) stator overload protection; (b) underexcitation protection; (c) overvoltage protection; (d) undervoltage protection; (e) overfrequency protection; (f) underfrequency protection; (g) reverse power protection; (h) forward power monitoring Op. 30.06.1994 Dec. 07.10.1994 - TC 9405417 8536.49.00 RELAYS, complying with British Railways Board specifications BR930 to BR968, NOT including bases or plugboards Op. 23.05.1995 Dec. 01.09.1995 - TC 9505702 8536.49.00 RELAYS, low profile, OTHER THAN reed relays, being EITHER of the following: (a) height NOT exceeding 21.24 mm; (b) height NOT exceeding 35 mm and having a continuous current rating NOT less than 8A AC Op. 31.12.1996 Dec. 25.03.1997 - TC 9613322 8536.49.00 CONTACTORS, DC TRACTION CIRCUIT, single pole, switching Op. 21.11.1997 Dec. 06.02.1998 - TC 9710270 8536.49.00 CONTACTORS, DC TRACTION, having ALL of the following: (a) a thermal current rating of NOT less than 80 A and NOT exceeding 600 A; (b) NOT exceeding 4 main poles; (c) maximum operating voltage NOT exceeding 1 000 V DC Op. 18.02.1998 Dec. 01.05.1998 - TC 9801489 8536.49.00 RELAYS, REED, dual in-line package (DIP) OR single in-line package (SIP) Op. 11.05.1998 Dec. 17.07.1998 - TC 9803965 8536.49.00 RELAYS, INTELLIGENT OBJECT TERMINAL Op. 10.08.1998 Dec. 23.10.1998 - TC 9807062 RELAYS, BIASED DIFFERENTIAL Op. 28.06.2001 Dec. 07.09.2001 - TC 0105156 8536.49.00 8536.50 SWITCHES, detector, stainless steel electro-mechanised hermetically sealed reed Op. 01.07.1983 Dec. 01.07.1983 - TC 8333314 8536.50 SWITCHES, limit, hunting tooth rotating shaft type, incorporating 2 or more electrically and mechanically separated switches Op. 01.11.1983 Dec. 01.11.1983 - TC 8333651 8536.50 SWITCHES, flow, operated by a predetermined liquid flow rate and having inlet and outlet pipe connections having an ID NOT exceeding 15 mm Op. 27.04.1984 Dec. 27.04.1984 - TC 8431292 8536.50 SWITCHES, limit, electrical valve stem two positioning, single pole, maximum in rush current 30 A with normally closed contacts, maximum in rush current 25 A with normally open contacts Op. 10.05.1984 Dec. 11.09.1984 - TC 8431558 Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8536.50 SWITCHES, thermal sensing, interlock, having a rated voltage NOT exceeding 300 V Op. 21.12.1984 Dec. 27.02.1986 - TC 8433839 8536.50 SWITCHES, push-button, piezoelectric, static, having no moving contacts Op. 24.12.1984 Dec. 11.04.1985 - TC 8435202 8536.50 SWITCHES, thumb wheel, including those operated by means of a lever, push-button or ratchet Op. 22.05.1984 Dec. 22.05.1984 - TC 8438118 8536.50 SWITCHES, vibration detector Op. 22.05.1984 Dec. 22.05.1984 - TC 8438123 SWITCHES, machine tool, oil tight, pedal actuated Op. 22.05.1984 Dec. 22.05.1984 - TC 8438587 SWITCHES, hall effect, magnetically operated Op. 22.05.1984 Dec. 22.05.1984 - TC 8438589 SWITCHES, mercury, metal clad Op. 22.05.1984 Dec. 22.05.1984 - TC 8438591 8536.50 8536.50 8536.50 8536.50 SWITCHES, limit, programmable, multiple cam OR shaft encoder operated Op. 22.05.1984 Dec. 22.05.1984 - TC 8438595 8536.50 SWITCHES, radio frequency, coaxial Op. 22.05.1984 Dec. 22.05.1984 - TC 8438601 8536.50 SWITCHES, rotary, having 3 or more operating positions, having a current rating NOT less than 125 A Op. 22.05.1984 Dec. 22.05.1984 - TC 8438603 8536.50 SWITCHES, rotary, having a sectional dia NOT exceeding 13 mm Op. 22.05.1984 Dec. 22.05.1984 - TC 8438608 8536.50 SWITCHES, slide, capable of being panel mounted in line at centres of 13 mm or less Op. 25.02.1985 Dec. 16.09.1985 - TC 8530625 8536.50 SWITCHES, remote loudspeaker selector Op. 23.07.1985 Dec. 23.07.1985 - TC 8533056 SWITCHES, thermal, diesel engine fan clutch Op. 17.07.1985 Dec. 21.03.1986 - TC 8533137 SWITCHES, motorcycle Op. 01.07.1985 - TC 8533601 8536.50 8536.50 Dec. 18.12.1985 8536.50 PARTS FOR VEHICLES which, if imported, would fall within Chapter 87 of the Customs Tariff Act 1987, being parts which are 30 years old or more For the purposes of TC 8632468 it is the importer"s responsibility to establish that the parts were manufactured 30 years or more prior to the date of importation Op. 01.01.1988 Dec. 01.01.1988 - TC 8632468 8536.50 SWITCHES, thermostatic, capillary tube/bulb sensor type, fixed temperature, manual reset Op. 09.04.1986 Dec. 18.08.1986 - TC 8633931 8536.50 SWITCHES, reed, enclosed in a hermetically sealed glass case Item 50 applies unless otherwise stated. Tariff Description =========================================================================== Op. 01.01.1988 Dec. 01.01.1988 - TC 8634296 8536.50 SWITCHES, trigger, variable speed, electric hand tool Op. 16.02.1988 Dec. 14.07.1988 - TC 8801708 8536.50 SWITCHES, modular, push button, incorporating a dual in line mounting package allowing for direct printed circuit board mounting, having integral collars allowing single or multiple chassis mounting, with or without chassis Op. 25.09.1989 Dec. 09.08.1990 - TC 8907590 8536.50 SWITCHES, having a mounting or actuating bushing dia of 6.5 mm or less AND capable of being panel mounted or actuated in line at 13 mm centres or less, but NOT including EITHER of the following: (a) hearing aid switches; (b) keyboard switches Op. 09.07.1990 Dec. 03.12.1990 - TC 9006030 8536.50 ELECTRONIC SAFETY (a) monitoring (b) monitoring (c) monitoring Op. 30.01.1991 8536.50 SWITCHES, having a mounting or actuating bushing dia of nominal 6.5 mm (+ or - 0.5 mm tolerance) or less and capable of being panel mounted or actuated in line at 13 mm centres or less, but NOT including EITHER of the following: (a) hearing aid switches; (b) keyboard switches Op. 06.08.1991 Dec. 23.03.1992 - TC 9107238 8536.50 SWITCH DISCONNECTORS, operational voltage of 500V AC, having ALL of following features: (a) disconnectors with 3 pole or 1 pole switching and isolating option; (b) AC22 rating for load switching; (c) dependent manual operation; (d) cable connecting capability design incorporating back, side, top and bottom connection options; (e) Impulse voltage Class III; (f) IP20 isolation in open position; (g) an integral current transformer option with the capability of remaining in the open circuit position under load conditions Op. 18.05.1992 Dec. 30.04.1993 - TC 9204965 8536.50.93 SWITCHES, being ANY of the following: (a) rotary, NOT less than 5 V and NOT greater than 25 V; (b) ignition, 2 OR 3 OR 4 position; (c) rocker, illuminated OR non-illuminated, having BOTH of the following: (i) NOT less than 10 V and NOT greater than 28 V; (ii) NOT less than 5 A and NOT greater than 35 A, (d) push button, having BOTH of the following: (i) NOT less than 5.5 V and NOT greater than 36.5 V; (ii) NOT less than 4.5 A and NOT greater than 50 A, (e) toggle, having BOTH of the following: (i) NOT less than 10 V and NOT greater than 28 V; (ii) NOT less than 0.5 A and NOT greater than 25.5 A, (f) rotary, push AND/OR pull, NOT less than 5 V and NOT greater than 25 V Op. 31.03.2011 Dec. 20.06.2011 - TC 1111085 Item 50 applies unless otherwise stated. SYSTEMS, consisting of ANY of the following: safety mats; safety strips; safety bumper systems Dec. 13.06.1991 - TC 9101800 Tariff Description =========================================================================== 8536.50.93 SWITCHES, electro magnetic, internal type, to suit compression ignition internal combustion piston engines (diesel) starter motors with pole housing OD 110 mm or greater Op. 01.07.1997 Dec. 01.07.1997 - TC 9703855 8536.50.93 PARTS, PASSENGER MOTOR VEHICLE, manufactured at least 30 years before the goods are entered for home consumption, or reproductions of these parts, being switches Op. 01.07.1997 Dec. 07.08.1997 - TC 9706171 8536.50.99 MOTOR MECHANISM MODULES, CIRCUIT BREAKER, impulse OR maintained control signal type, having ALL of the following; (a) rated current NOT less than 50 A and NOT greater than 650 A; (b) operating frequency NOT greater than 5 per minute; (c) opening response time NOT greater than 650 ms and closing response time NOT greater than 90 ms; (d) opening OR closing power consumption NOT greater than 550 VA Op. 23.03.2016 Dec. 22.06.2016 - TC 1611501 8536.50.99 CIRCUIT BREAKERS, AIR INSULATED, manual, including ALL of the following: (a) current rating NOT less than 630 A and NOT greater than 6 300 A; (b) 3 OR 4 pole; (c) voltage NOT less than 415 V and NOT greater than 1 000 V; (d) spring charge operation; (e) ready-to-close indicator Op. 23.03.2016 Dec. 15.06.2016 - TC 1611487 8536.50.99 SWITCHES, coded magnetic, multiple pole, having BOTH of the following: (a) operating voltage NOT less than 24 V DC; (b) operating current NOT greater than 100 A Op. 05.06.2015 Dec. 24.08.2015 - TC 1520674 8536.50.99 LIMIT SWITCHES, rotary head, multiple pole, having an operating voltage NOT less than 125 V and NOT greater than 250 V Op. 04.06.2015 Dec. 31.08.2015 - TC 1520569 8536.50.99 SAFETY SWITCHES, interlock, key turret head, single OR multiple pole, AC/DC, having BOTH of the following: (a) supply voltage NOT less than 24 V, and NOT greater than 250 V; (b) slow break-before-make contact operation Op. 09.06.2015 Dec. 31.08.2015 - TC 1521060 8536.50.99 SAFETY LIMIT SWITCHES, multiple pole, having ANY of the following: (a) snap action contact; (b) insulation voltage NOT greater than 600 V; (c) end plunger OR roller plunger OR roller lever Op. 09.06.2015 Dec. 31.08.2015 - TC 1521061 8536.50.99 SWITCHES, TOUCH CONTROL, electronic, 240V AC, having ALL of the following: (a) touch switch sensors; (b) glass front plates; (c) tri colour LED button indicators; (d) child lock mode; (e) timers; (f) ambient light level control sensors; Item 50 applies unless otherwise stated. Tariff Description =========================================================================== (g) over current AND/OR over temperature protection; (h) with OR without ANY of the following: (i) wireless remote control; (ii) wireless group control; (iii) dimming mode Op. 02.01.2015 Dec. 23.03.2015 - TC 1500013 8536.50.99 PRESSURE SWITCHES, TRAIN CARRIAGE DOOR OPENING AND CLOSING, electro-pneumatic Op. 30.01.2015 Dec. 20.04.2015 - TC 1504374 8536.50.99 SWITCH FUSES, including ALL of the following: (a) voltage capacity NOT greater than 1 000 V; (b) double insulated external handles; (c) contacts position indicated by handle; (d) IP 20 protection when open; (e) sealable fuse covers Op. 20.12.2013 Dec. 17.03.2014 - TC 1400297 8536.50.99 SWITCHES, ISOLATING, AC OR DC, enclosed, for a voltage NOT exceeding 1000 V, Ingress Protection (IP) rated IP 66 OR IP 67 Op. 09.04.2013 Dec. 08.07.2013 - TC 1312090 8536.50.99 FUSE SWITCH DISCONNECTORS, having an operational voltage NOT exceeding 690 V AC, having ALL of the following: (a) capable of single or three phase switching; (b) AC 23 rating for load switching; (c) dependant manual operation; (d) IP20 isolation Op. 31.05.2013 Dec. 01.07.2013 - TC 1319681 8536.50.99 DISCONNECTORS, FUSE SWITCH, operational voltage 660 V AC, having ALL of the following: (a) capable of single or three phase switching; (b) AC23 rating for load switching; (c) IP20 isolation; (d) suitable for 100 mm or 185 mm phase centres; (e) an integral current transformer option with the capability of remaining in the open circuit position under load conditions Op. 31.05.2013 Dec. 01.07.2013 - TC 1319680 8536.50.99 FUSE SWITCH DISCONNECTORS, operational voltage 660 ALL of the following: (a) capable of single phase operation; (b) AC23 rating for load switching; (c) dependant manual operation; (d) IP20 isolation; (e) suitable for 210 mm phase centres; (f) an integral current transformer option with capability of remaining in the open circuit under load conditions Op. 31.05.2013 Dec. 01.07.2013 - V AC, having the position TC 1319679 8536.50.99 FUSE SWITCH DISCONNECTORS, three phase switching, having BOTH of the following: (a) operational voltage NOT greater than 690 V; (b) rated operational current NOT less than 160 A and NOT greater than 1 250 A Op. 31.05.2013 Dec. 01.07.2013 - TC 1319682 8536.50.99 SWITCHES, being ANY of the following: (a) disconnect, having BOTH of the following: (i) NOT less than 5 V but NOT greater than 37 V; Item 50 applies unless otherwise stated. Tariff Description =========================================================================== (ii) NOT less than 2 A but NOT greater than 125 A continuous, (b) disconnect, having ALL of the following: (i) NOT less than 5 V but NOT greater than 37 V; (ii) NOT less than 120 A but NOT greater than 130 A continuous; (iii) NOT less than 740 A but NOT greater than 1 010 A intermittent, (c) limit, micro, having BOTH of the following: (i) temperature range NOT less than minus 11 degrees Celsius but NOT greater than 120 degrees Celsius; (ii) rating NOT less than 1.4 A but NOT greater than 6 A, (d) rocker, illuminated OR non-illuminated, having BOTH of the following: (i) NOT less than 10 V but NOT greater than 28 V; (ii) NOT less than 5 A but NOT greater than 35 A Op. 19.04.2011 Dec. 11.07.2011 - TC 1113008 8536.50.99 SWITCHES, LIMIT, hunting tooth, rotating shaft Op. 08.03.2011 Dec. 30.05.2011 - TC 1108450 8536.50.99 FLOAT SWITCHES, running ball actuated, having a power rating NOT less than 6 V and NOT greater than 32 V Op. 25.03.2010 Dec. 08.07.2010 - TC 1014657 8536.50.99 SWITCHES, FIRE ALARM, manual Op. 26.03.2010 Dec. 18.06.2010 - TC 1014870 8536.50.99 SWITCHES, WATERFLOW MONITORING, SPRINKLER SYSTEM, comprising BOTH of the following: (a) vane water flow switch; (b) switch tester, including ALL of the following: (i) pump; (ii) valves; (iii) pipes; (iv) pipe fittings Op. 04.08.2009 Dec. 16.10.2009 - TC 0928220 8536.50.99 SWITCHES, waterflow activated, vane type Op. 28.05.2009 Dec. 21.08.2009 - TC 0918155 8536.50.99 RESIDUAL CURRENT DEVICES (RCD), non DIN rail mounted Op. 05.02.2009 Dec. 01.05.2009 - TC 0903884 8536.50.99 SWITCHES, POSITION CONTROLLER, LINEAR ACTUATOR Op. 24.10.2005 Dec. 23.01.2006 - TC 0514830 8536.50.99 LOCKS, electric key switch, comprising BOTH of the following: (a) keys; (b) housing assembly Op. 22.11.2005 Dec. 16.02.2006 - TC 0603928 8536.50.99 LOCKS, electric key switch, comprising BOTH of the following: (a) keys; (b) wiring loom Op. 22.11.2005 Dec. 16.02.2006 - TC 0603937 8536.50.99 SWITCHES, DIFFERENTIAL PRESSURE Op. 23.05.2006 Dec. 04.08.2006 - TC 0608855 SWITCHES, ELECTRIC, ROTARY Op. 09.02.2007 Dec. 04.05.2007 - TC 0702118 8536.50.99 Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8536.50.99 PARTS, ON-ROAD TRUCKS HAVING A GROSS VEHICLE WEIGHT NOT LESS THAN 7.5 TONNES, being EITHER of the following: (a) electrical switches; (b) actuators Op. 19.09.2007 Dec. 10.12.2007 - TC 0715784 8536.50.99 PARTS, OFF-HIGHWAY TRUCKS AND EARTHMOVING MACHINES HAVING A VOLTAGE RATING NOT LESS THAN 24 V, being EITHER of the following: (a) electrical switches; (b) actuators Op. 22.04.2008 Dec. 11.07.2008 - TC 0805552 8536.50.99 SWITCHES, SAFETY GATE MONITORING, being ANY of the following: (a) mechanical switches; (b) non-contact magnetic switches; (c) non-contact radio frequency coded switches Op. 12.06.2008 Dec. 08.09.2008 - TC 0812471 8536.50.99 RESIDUAL CURRENT DEVICE (RCD), DIN rail mount Op. 05.09.2008 Dec. 28.11.2008 - TC 0829886 8536.50.99 RESIDUAL CURRENT DEVICES, industrial, hydraulic magnetic, conforming to Australian/New Zealand Standard AS/NZS 3190:2002 Op. 05.12.2008 Dec. 27.02.2009 - TC 0842821 8536.50.99 SWITCHES, push button, illuminated, being ANY of the following: (a) square; (b) rectangular; (c) circular Op. 01.07.1993 Dec. 02.07.1993 - TC 9304006 8536.50.99 SWITCHES, LOAD BREAK, with a rated operational voltage of 660 V AC or greater, but NOT exceeding 1 000 V AC, having ALL of the following: (a) spring compression make and break assembly directly coupled to a one piece contact carrier; (b) operational current rating of 40 A or greater, but NOT exceeding 1 600 A; (c) 3, 4, 6 or 8 pole configuration; (d) front or side operation Op. 26.07.1993 Dec. 29.10.1993 - TC 9307174 8536.50.99 SWITCHES, flow, operated by a predetermined fluid flow rate and having inlet and outlet pipe connections having an ID NOT exceeding 15 mm Op. 01.07.1993 Dec. 02.07.1993 - TC 9318161 8536.50.99 SWITCHES, momentary action, having a body diameter, excluding flange, of less than 3 mm Op. 01.07.1993 Dec. 02.07.1993 - TC 9318385 8536.50.99 SWITCHES, diaphragm activated, maximum operational current rating 16 A Op. 19.08.1994 Dec. 25.11.1994 - TC 9406914 8536.50.99 SWITCHES, video cassette recorders, being ANY of the following: (a) CAM switches; (b) rotary encoders; (c) mode switches; (d) coder switches; (e) switch mode selectors; (f) slide encoders Op. 27.10.1994 Dec. 30.01.1995 - TC 9408577 Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8536.50.99 ELECTRIC CONTACT MATS, being hermatically encased pressure operated contact switches, having ALL of the following: (a) intermittent load NOT exceeding 70 kPa/sq cm; (b) temperature range -35 to +50 deg.C; (c) nominal control voltage of 12-48 V, 50/60 cycles per second; (d) nominal operating current of 0.1 Amp, 50/60 cycles per second; (e) weight of mat NOT exceeding 100 kg; (f) thickness of mat NOT exceeding 25 mm; Op. 26.04.1995 Dec. 18.08.1995 - TC 9505145 8536.50.99 SWITCHES, AIR CONDITIONING REFRIGERANT PRESSURE SENSING, being ANY of the following: (a) low pressure cut out, range 1.5 kg/cm2 to 2.5 kg/cm2 (inclusive); (b) high pressure cut out, range 21.0 kg/cm2 to 38.0 kg/cm2 (inclusive); (c) combined low and high pressure cut out in the following range: (i) low pressure cut out, range 1.5 kg/cm2 to 2.5 kg/cm2 (inclusive); (ii) high pressure cut out, range 21.0 kg/cm2 to 38.0 kg/cm2 (inclusive); (d) combined low and high pressure cut out with electric fan operating circuit in the following range: (i) low pressure cut out, range 1.5 kg/cm2 to 2.5 kg/cm2 (inclusive); (ii) high pressure cut out, range 21.0 kg/cm2 to 38.0 kg/cm2 (inclusive); (iii) fan circuit cut in, range 15.0 kg/cm2 to 18.0 kg/cm2 (inclusive); Op. 09.05.1995 Dec. 01.09.1995 - TC 9505405 8536.50.99 INTERLOCK SAFETY SWITCHES, mechanical, hinge, tong or electronically actuated, having BOTH of the following characteristics: (a) water tight housing to IP 67 as defined in AS 1939; (b) positive acting contact block Op. 23.06.1995 Dec. 29.09.1995 - TC 9508450 8536.50.99 SWITCHES, LOAD BREAK, with a rated operational voltage of 660 V AC or greater but NOT exceeding 1 000 V AC, having ALL of the following: (a) spring compression make and break assembly directly coupled to a one piece contact carrier; (b) operational current of 250 A or greater; (c) 3, 4, 6 or 8 pole configuration; (d) front, side or motorised operation Op. 01.11.1995 Dec. 15.02.1996 - TC 9511592 8536.50.99 SWITCH, STARTER, fluorescent tube Op. 21.03.1997 Dec. 16.06.1997 - TC 9702142 8536.50.99 SWITCHES, ROTARY, PANEL MOUNT, having ALL of the following: (a) mounting bush 6.5 mm OR less; (b) more than one operating position; (c) 1,2,3 OR 4 poles Op. 11.05.1998 Dec. 17.07.1998 - TC 9803963 8536.50.99 SWITCHES, PRINTED CIRCUIT BOARD, multi-actuator, dual in-line package (DIP) OR surface-mount package (SMP) Op. 11.05.1998 Dec. 17.07.1998 - TC 9803964 8536.50.99 SWITCHES, PRINTED CIRCUIT BOARD, surface-mount OR through-hole, having BOTH of the following: (a) current rating NOT exceeding 100.0 mA; (b) voltage rating NOT exceeding 50 V AC OR DC Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8536.50.99 Op. 15.05.1998 Dec. 31.07.1998 - TC 9804137 SWITCHER BOXES, PRINTER Op. 18.01.1999 Dec. 07.04.1999 - TC 9900470 8536.50.99 SWITCHES, being ANY of the following: (a) toggle, 240 V AC, current capacity NOT exceeding 3 A; (b) toggle, 28 V DC, current capacity NOT exceeding 3 A; (c) toggle, 125 V AC, current capacity NOT exceeding 6 A; (d) toggle, 250 V AC, current capacity NOT exceeding 6 A; (e) toggle, 12 V DC, current capacity NOT exceeding 16 A; (f) push button, max 250 V AC, current capacity NOT exceeding 1 A; (g) rocker, 12 V DC, current capacity NOT exceeding 30 A; (h) rocker, 250 V AC, current capacity NOT exceeding 10 A; (i) rocker, max 250 V AC, current capacity NOT exceeding 6 A; (j) numeric keypad; (k) 4-way, 100 V AC 0.5 A OR 25 V DC 1 A; (l) push button, 100 V AC 0.5 A OR 25 V DC 1 A; (m) micro OR mini-micro, max 250 V AC, current capacity NOT exceeding 10 A; (n) knife, 50 V DC; (o) mercury, 24 V DC, current capacity NOT exceeding 2 A Op. 08.02.1999 Dec. 23.04.1999 - TC 9900975 8536.50.99 MATS, PRESSURE, alarm or signal activation Op. 20.05.1999 Dec. 20.08.1999 - TC 9903561 SWITCHES, TRIANGULAR, PUSH BUTTON, illuminated Op. 02.08.2001 Dec. 22.11.2001 - TC 0106713 SWITCHES, hexagonal, push button, illuminated Op. 03.09.2004 Dec. 15.11.2004 - TC 0409076 SWITCHES, energy regulator Op. 09.12.2004 Dec. 11.02.2005 - TC 0413470 8536.50.99 8536.50.99 8536.50.99 8536.61 SOCKETS, 6 V or 12 V, single contact, being lamp receptacles with insulating sleeves Op. 11.11.1985 Dec. 30.05.1986 - TC 8534974 8536.61.00 LAMP HOLDERS, having BOTH of the following: (a) voltage capacity NOT less than 240 V AC; (b) bayonet cap Op. 19.01.2015 Dec. 08.04.2015 - TC 1502607 LAMPHOLDERS, CERAMIC Op. 14.02.1994 - TC 9402252 8536.61.00 Dec. 20.05.1994 8536.61.00 LAMP HOLDERS, Being EITHER of the following: (a) ceramic, with the metal conductors sealed within the holder body, excluding fluorescent,SBC, BC, and ES type holders; (b) moulded plastic, with a removable cable/wire cover having the metal conductors sealed within the holder body, excluding fluorescent, SBC, BC, and ES type holders Op. 02.05.1994 Dec. 02.09.1994 - TC 9404471 8536.61.00 LAMPHOLDERS, fluorescent for G13 cap lamps, with or without starter holder, having ALL of the following: (a) push fix or push through mounting; (b) polycarbonate body moulding; (c) polybutylenterephthalat rotor moulding; (d) phosphor bronze electrical contacts and self locking terminals; (e) manufactured to IEC 61-2, IEC400/EN 60400 with temperature Item 50 applies unless otherwise stated. Tariff Description =========================================================================== rating T110 or above but NOT including lampholders of the following type: (a) tombstone lampholders for 10.3-10.5 x 25.5 mm metalware cut out; (b) tombstone or end fixing button design with screw terminals for wire connection Op. 28.06.1994 Dec. 30.09.1994 - TC 9405371 8536.61.00 SOCKETS, GLOBE, EDISON SCREW Op. 01.03.1999 Dec. 14.05.1999 - TC 9901494 8536.69 ADAPTORS, plug, audio equipment connector, being ANY of the following: (a) 3.5 mm plug to 6.5 mm socket; (b) 6.3 mm plug to 3.5 mm socket; (c) 6.3 mm plug to RCA socket; (d) RCA plug to 3.5 mm socket; (e) RCA plug to 6.5 mm socket; (f) 3.5 mm plug to RCA socket Op. 22.05.1984 Dec. 22.05.1984 - TC 8438329 8536.69 JACKS, phono, RCA Type Op. 22.05.1984 Dec. 22.05.1984 - TC 8438480 SOCKETS, cathode ray tube Op. 22.05.1984 Dec. 22.05.1984 - TC 8438562 8536.69 8536.69 PLUGS, phone, having a plug finger dia of 4.3 mm or greater but NOT exceeding 4.5 mm Op. 23.01.1986 Dec. 23.01.1986 - TC 8632249 8536.69 PARTS FOR VEHICLES which, if imported, would fall within Chapter 87 of the Customs Tariff Act 1987, being parts which are 30 years old or more For the purposes of TC 8632469 it is the importer"s responsibility to establish that the parts were manufactured 30 years or more prior to the date of importation Op. 01.01.1988 Dec. 01.01.1988 - TC 8632469 8536.69 PLUGS OR SOCKETS, surface mounting, having a current rating of 300 A or greater at 440 V Op. 15.04.1986 Dec. 17.10.1986 - TC 8633092 8536.69 PLUGS, two pin, having ALL of the following: (a) rated voltage 240 V/250 V; (b) rated current 10 A/16 A; (c) temperature resistance NOT less than 200 degrees C Op. 08.12.1987 Dec. 26.08.1988 - TC 8733946 8536.69 PLUGS/SOCKETS, adaptor being EITHER of the following: (a) providing for plug or socket configurations used in other countries to connect to Australian standard plugs or sockets; (b) providing for plug or socket configurations of Australian standard type to connect to plugs or sockets used in other countries Op. 17.06.1988 Dec. 28.04.1989 - TC 8807068 8536.69 CONNECTORS, multi-pin D sub-miniature type, male or female but NOT including connectors of the insulation displacement type or connectors imported with back shells or connectors assembled with back shells to form plugs or interconnecting leads made up utilising such plugs Op. 30.10.1989 Dec. 15.05.1991 - TC 8908625 Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8536.69 CONNECTORS, 10, 14, 24, 36, 50 or 64 position, complying with or interchangeable with connectors complying with British Telecom (BT) specification D2635A for connector 226 Op. 30.10.1989 Dec. 15.05.1991 - TC 8908626 8536.69 PLUGS, 6.3 mm dia, mono or stereo with tip ring(s) and sleeve Op. 18.06.1990 Dec. 11.11.1991 - TC 9005424 8536.69 TERMINAL STRIPS, plug in type, for panel/chassis mounting, 2 to 12 poles, having ALL of the following: (a) moulding made of natural polyamide; (b) temperature limits: (i) short time 140 - 160 degrees C; (ii) continuous 80 - 100 degrees C; (iii) cold resistance minus 40 degrees C; (c) terminal body made of nickel plated brass with spring clips made of stainless steel and screws of zinc plated steel yellow chromated; (d) centre to centre spacing in different models of 8, 10 and 11.5 mm; (e) rated current in different models of 6 A, 16 A and 25 A; (f) rated voltage 380 V to VDE 0110 insulation group B Op. 26.03.1991 Dec. 28.10.1991 - TC 9103138 8536.69 CONTACT PINS, male or female, gold plated, being parts for data terminating equipment and data circuit termination equipment interface connectors which conform/comply with ALL of the following: (a) ISO standard 2593 as revised by ISO TC 97/SC6 N2599 and 3236; (b) Consultative Committee International Telegraph and Telephones (CCITT) standards for data transmission at 48 kilobites per second using 60-108 kHz group band circuits; (c) US military specification MIL-C-39029 and its equivalents Op. 11.09.1991 Dec. 28.05.1992 - TC 9108146 8536.69 PLUGS, phono, RCA type Op. 06.02.1992 Dec. 05.06.1992 - TC 9201808 8536.69 PLUGS, modular, telephone, to suit RJ 11 sockets and complying with US Standard FCC 68 Op. 03.04.1992 Dec. 03.12.1992 - TC 9203687 8536.69.90 POWER POINTS, printed circuit board, single OR multiple power outlets, with OR without EITHER of the following: (a) single OR multiple touch controlled power switches; (b) wireless group control Op. 15.01.2015 Dec. 08.04.2015 - TC 1502315 8536.69.90 POWER POINTS, plastic AND/OR metal, single OR multiple power outlet, with OR without EITHER of the following: (a) LED (light-emitting diode) night light; (b) single OR multiple power switches Op. 20.11.2014 Dec. 28.01.2015 - TC 1440896 8536.69.90 RECEPTACLE CONNECTORS, UMBILICAL REELER, OIL AND/OR GAS WELL EQUIPMENT, electrical, whether OR not assembled, having NOT less than 8 pins Op. 18.12.2013 Dec. 07.04.2014 - TC 1341827 8536.69.90 POWER POINTS, plastic, with OR without USB portal OR LED night light portal, being ANY of the following: Item 50 applies unless otherwise stated. Tariff Description =========================================================================== (a) single outlet; (b) double outlet; (c) triple outlet; (d) quadruple outlet Op. 11.10.2012 Dec. 02.01.2013 - TC 1238825 8536.69.90 DOUBLE ADAPTORS, POWER POINT, with OR without surge protectors Op. 03.07.2012 Dec. 19.09.2012 - TC 1223271 8536.69.90 CONNECTORS, AUDIO AND/OR VIDEO, being ANY of the following: (a) plugs; (b) sockets; (c) adaptors Op. 11.07.2012 Dec. 26.09.2012 - TC 1224318 8536.69.90 BALLAST, PLUG PACK, 240 volt Op. 28.11.2005 Dec. 13.02.2006 - TC 0516610 ADAPTORS, BATTERY, MOBILE PHONE Op. 14.12.2006 Dec. 09.03.2007 - TC 0619719 8536.69.90 8536.69.90 CONNECTORS, ELECTRICAL, MODULAR, complying with Australian/New Zealand Standard AS/NZS 3080:2003 and American National Standards Institute, Telecommunications Industry Association/Electronic Industries Alliance, TIA/EIA-568-B.2 Op. 16.06.2008 Dec. 01.09.2008 - TC 0812833 8536.69.90 CONNECTORS, switching, electrical, having ALL of the following: (a) single OR three phase switching; (b) current rating NOT less than 16 A and NOT greater than 250 A; (c) operating voltage NOT greater than 690 V; (d) AC23 rating for load switching; (e) dependant manual operation; (f) IP (International Protection) 20 rating Op. 24.06.2008 Dec. 12.09.2008 - TC 0814287 8536.69.90 JACKS, CONNECTION, DATA CABLE Op. 25.09.2008 Dec. 12.12.2008 - TC 0832745 8536.69.90 CHIPCARD ACCEPTOR DEVICES, having 6 data contacts, incorporating an integrated security switch Op. 01.07.1997 Dec. 01.07.1997 - TC 9703863 8536.69.90 SOCKETS, 3, 4 or 5 pin, gold contact, having a socket diameter of less than 3 mm Op. 01.07.1997 Dec. 01.07.1997 - TC 9703864 8536.69.90 ADAPTORS, TELEPHONE OR COMPUTER, being ANY of the following: (a) TELEPHONE: (i) standard line to modular; (ii) two device connection to one socket or plug; (b) COMPUTER: (i) 25 pin to 25 pin; (ii) 9 pin to 25 pin; (iii) gender changers; (iv) RJ11 to D825; (v) 6 pin to 5 pin Op. 01.07.1997 Dec. 01.07.1997 - TC 9703865 8536.69.90 CONNECTORS, having a minimum pressure rating of 100 bar (10 kPa) Op. 01.07.1997 Dec. 01.07.1997 - TC 9703866 Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8536.69.90 CONNECTORS, electrical, circular bayonet type, manufactured in accordance with EITHER VG 95 234 OR MIL C 5015 Op. 01.07.1997 Dec. 01.07.1997 - TC 9703902 8536.69.90 CONNECTORS, electrical, incorporating twist locking mechanism Op. 01.07.1997 Dec. 01.07.1997 - TC 9703905 8536.69.90 PANELS, single channel access, modular video/audio Op. 01.07.1997 Dec. 01.07.1997 - TC 9704314 8536.69.90 CONNECTORS, electrical, being ANY of the following: (a) rectangular rack and panel; (b) cylindrical; or (c) RF coaxial and manufactured in accordance with ANY of the following military specifications listed in the table below: TABLE Rectangular rack and panel connectors MIL-C-8384, MIL-C-21671, MIL-C-26518, MIL-C-28731, MIL-C-28748, MIL-C-28804, MIL-C-81659, MIL-C-83527, MIL-C-83733, MIL-C-85028, ARINC 600, ARINC 404 Cylindrical connectors MIL-C-85049, MIL-C-22539, MIL-C-26500, MIL-C-38999, MIL-C-81703, MIL-C-5015, MIL-C-22992, MIL-C-83723, MIL-C-55116, MIL-C-83723, MIL-C-10544, MIL-C-24217, MIL-C-27599, MIL-C-55181, NAS 1599 MIL-C-12520, MIL-C-25955, MIL-C-28840, MIL-C-55243, MIL-C-22249, MIL-C-26482, MIL-C-38300, MIL-C-81511. RF coaxial connectors MIL-A-55339, MIL-C-3643, MIL-C-3650, M26637/1, M26337/2, M39012/07, M39012/08, M39012/09, M39012/10, M39012/11, M39012/12, M39012/14, M39012/18, M39012/20, M39012/23, M39012/24, M39012/29, M39012/30, M39012/33, M39012/34, M39012/35, M39012/36, M39012/37, M39012/38, M39012/39, M39012/40, M39012/41, M39012/42, M39012/43, M39012/44, M39012/45, M39012/46, M39012/47, M39012/48, M39012/49, M39012/55, M39012/56, M39012/57, M39012/58, M39012/60, M39012/61, M39012/62, M39012/63, M39012/64, M39012/65, M39012/66, M39012/67, M39012/68, M39012/69, M39012/70, M39012/71, M39012/73, M39012/74, M39012/75, M39012/76, M39012/77, M39012/79, M39012/80, M39012/81, M39012/82, M39012/84, M39012/85, M39012/86, M39012/87, M39012/88, M39012/89, M39012/90, M39012/91, M39012/92, M39012/93, M39012/94, M39012/95, M39012/96, M39012/100, M39012/101, M39012/102, M39012/103, M39012/104, M3655/01, M3655/02, M3655/04, M3655/05, M3655/06, M3655/07, M3655/08, M3655/09, M3655/10, M3655/11, M3655/12, M3655/13, M3655/14, M3655/15, M3655/16, M3655/17, M3655/18, M3655/19, M3655/20, M3655/21, M3655/22, M3655/23, M35516/16, M25516/17, M25516/18, M25516/19, M25516/20, M25516/21, M25516/22, M25516/25, M25516/27, M25516/28, M25516/29, M27434/5, Op. 01.07.1997 Dec. 19.08.1998 - TC 9706627 8536.69.90 8536.69.90 SOCKETS, INTEGRATED CIRCUIT Op. 30.07.1997 Dec. 10.10.1997 - TC 9706648 TERMINATORS, COMPUTER, having ALL of the following: (a) SCSI (small computer system interface) configuration; Item 50 applies unless otherwise stated. Tariff Description =========================================================================== (b) 68 position high density female connectors, with latches; (c) supply voltage handling from 3.7 V to 5.05 V; (d) input capacitance at connector pin NOT exceeding 15 picoFarads Op. 30.12.1997 Dec. 27.03.1998 - TC 9711357 8536.69.90 CONNECTORS, electronic, insulation displacing contacts (IDC), mass termination, having BOTH of the following: (a) self-aligning cable grooves; (b) integral side latches Op. 01.07.1997 Dec. 26.03.1998 - TC 9802032 8536.69.90 PLUGS OR JACKS, THERMOCOUPLE CIRCUITRY Op. 28.04.1998 Dec. 10.07.1998 - TC 9803546 PLUGS, being ANY of the following: (a) single pin, NOT exceeding 3.5 mm; (b) micro, single pin, 2 mm; (c) DC power, 1.3 mm, 2.1 mm OR 2.5 mm; (d) 9 pin OR 15 pin, sub D; (e) 2, 4 OR 8 pole microphone connection; (f) 2, 3, 5, 6, 7, 8 OR 13 pin DIN Op. 04.02.1999 Dec. 23.04.1999 - TC 9900882 8536.69.90 8536.69.90 SOCKETS, being ANY of the following: (a) single pin, NOT exceeding 3.5 mm; (b) micro, single pin, 2 mm; (c) DC power connector, 2.1 mm OR 2.5 mm; (d) 9 pin OR 15 pin, sub D; (e) 2, 4 OR 8 pole microphone connector; (f) 2, 3, 5, 6, 7, 8 OR 13 pin DIN; (g) 16, 20, 26, 34, 40 OR 50 way dual in line crimp-on Op. 04.02.1999 Dec. 23.04.1999 - TC 9900883 8536.69.90 PLUG AND SOCKET COMBINATIONS, being ANY of the following: (a) 2, 3, 4, 6, 9, 12 OR 15 way, rated to 300 V, maximum current of 15 amps; (b) 2, 3 OR 12 way, single in line pin header; (c) 1.3 mm plug to 2.1 mm socket; (d) 2.5 mm plug to 3.5 mm socket Op. 05.02.1999 Dec. 23.04.1999 - TC 9900931 8536.69.90 CONNECTORS, being ANY of the following: (a) bayonet naval connector adaptors; (b) male to male 3.5 mm pin coaxial adaptors; (c) cable joiner coaxial adaptors; (d) 3.5 mm plug to 3.5 mm sockets; (e) 3.5 mm plug to 6.5 mm sockets; (f) video plugs; (g) car radio antennae plugs; (h) car radio antennae sockets Op. 03.03.1999 Dec. 21.05.1999 - TC 9901580 CONNECTORS, OPTICAL FIBRE Op. 12.06.2007 - TC 1215858 8536.70.19 8536.70.19 8536.70.40 Dec. 31.05.2012 CASSETTES, FIBER OPTIC, with OR without adapters Op. 19.12.2011 Dec. 26.04.2012 - TC 1141976 FIBRE OPTIC CABLE CONNECTOR ASSEMBLIES, including ALL of the following: (a) steel shelf; (b) fibre optic cable organising and connecting trays; (c) fibre optic cable pigtails; (d) ceramic connector adapters Item 50 applies unless otherwise stated. Tariff Description =========================================================================== Op. 13.06.2013 8536.70.90 8536.70.90 8536.90 Dec. 09.09.2013 - TC 1319648 CASSETTES, FIBER OPTIC, with OR without adapters Op. 19.12.2011 Dec. 26.04.2012 - TC 1141964 CONNECTORS, OPTICAL FIBRE Op. 12.06.2007 Dec. 31.08.2007 - TC 0708845 PROBES, multimeter Op. 20.03.1984 Dec. 20.03.1984 - TC 8342739 8536.90 CONNECTORS, triax OR quad, having ALL of the following characteristics: (a) fully rotatable; (b) insertion loss at 10 MHz to 200 MHz (both inclusive) NOT exceeding 0.2 dB OR at 200 MHz to 800 MHz (both inclusive) NOT exceeding 0.5 dB ; (c) minimum 250 V AC insulation; (d) capable of carrying 2 A at 15 V AC or DC; (e) capable of suspending electronic equipment having a weight of 10 kg Op. 25.07.1983 Dec. 25.07.1983 - TC 8432273 8536.90 THERMOCOUPLE CONNECTING HEADS, but NOT including those constructed from aluminium OR cast iron Op. 22.05.1984 Dec. 22.05.1984 - TC 8438108 8 536.90 8536.90 8536.90 8536.90 VIBRATORS Op. 22.05.1984 Dec. 22.05.1984 - TC 8438135 CONNECTORS, voltage selecting and fused Op. 22.05.1984 Dec. 22.05.1984 - TC 8438360 HOLDERS, dry cell Op. 22.05.1984 Dec. 22.05.1984 - TC 8438464 PROBES, test, electronic micro-circuit Op. 04.02.1988 Dec. 30.06.1988 - TC 8801105 8536.90 CLAMPS, work, arc-welding, spring loaded, minimum current capacity 300 A, but NOT including rotating types Op. 22.01.1988 Dec. 24.08.1989 - TC 8801898 8536.90.90 POWER OUTLETS, having BOTH of the following: (a) combination switch AND socket housing; (b) compliance with International Electrotechnical Commission Standard 60529 (IEC 60529) Ingress Protection Rating 66 (IP 66) Op. 18.09.2014 Dec. 15.12.2014 - TC 1433273 8536.90.90 JUNCTION BOXES, ELECTRICAL, RAILWAY, having BOTH of the following: (a) voltage rating NOT greater than 750 V AC; (b) voltage rating NOT greater than 500 V DC Op. 09.12.2013 Dec. 03.03.2014 - TC 1340740 8536.90.90 INSTRUMENT JUNCTION BOXES, stainless steel, single OR dual strip, incorporating analogue AND/OR digital terminal blocks, having a power rating NOT greater than 600 V Op. 22.09.2011 Dec. 19.12.2011 - TC 1132491 8536.90.90 CLOCKSPRINGS, STEERING COLUMN, MOTOR VEHICLE Op. 02.09.2009 Dec. 20.11.2009 Item 50 applies unless otherwise stated. - TC 0932406 Tariff Description =========================================================================== 8536.90.90 JUNCTION BOXES, OFFSHORE PLATFORM, having BOTH of the following: (a) subsea umbilical cable connection terminals; (b) AC electrical maximum power capacity NOT less than 1 000 V Op. 30.07.2009 Dec. 23.10.2009 - TC 0927439 8536.90.90 LUGS, being solderable, copper connectors Op. 23.08.2006 Dec. 10.11.2006 - TC 0613954 8536.90.90 CONNECTION AND CONTACT ELEMENT MODULES, TELEPHONE CABLE Op. 25.09.2008 Dec. 12.12.2008 - TC 0832746 8536.90.90 CONNECTORS, PRINTED CIRCUIT BOARD, insulation displacement, 3, 4 or 8 pole Op. 18.02.1998 Dec. 08.05.1998 - TC 9801457 8536.90.90 CATHODIC PROTECTION TEST STATIONS Op. 01.12.1998 Dec. 26.02.1999 - TC 9810483 8536.90.90 CLIPS, BATTERY TERMINAL OR ELECTRONIC, being EITHER of the following: (a) crocodile; (b) alligator Op. 01.03.1999 Dec. 14.05.1999 - TC 9901493 8537.10 CONTROLLERS, sequence, joy stick type, with spring return to central off position Op. 22.05.1984 Dec. 22.05.1984 - TC 8438384 8537.10 CONTROLS, dictating/transcribing machine Op. 22.05.1984 Dec. 22.05.1984 - TC 8438385 CONTROL PANELS, remote, television camera Op. 22.05.1984 Dec. 22.05.1984 - TC 8438444 8537.10 8537.10 HANDSETS, remote control, with cable to enable connection to video cassette recorders OR video cameras Op. 24.12.1985 Dec. 18.04.1986 - TC 8535600 8537.10.90 CONTROL BOXES, TRAM, being EITHER of the following: (a) points controlling unit; (b) inside tram controlling unit AND/OR antenna unit Op. 16.06.2016 Dec. 12.09.2016 - TC 1620566 8537.10.90 ORDER PICKING CONTROL STATION, horizontal, having BOTH of the following: (a) adjustable work platform; (b) pick-to-light system based touch screen monitor Op. 26.05.2016 Dec. 22.08.2016 - TC 1618994 8537.10.90 OUTLETS, POWER AND/OR DATA, pre-wired, table surface AND/OR below table surface mountable, including ANY of the following: (a) flip-up outlet lid; (b) manual pull-up column OR box; (c) gas spring pop-up column OR box Op. 10.05.2016 Dec. 01.08.2016 - TC 1617008 8537.10.90 POLES, aluminium, anodized, hollow, incorporating a plastic covering, including ANY two of the following: (a) earth clamps; (b) earth terminal; (c) flexible plastic conduit; (d) earth cable Op. 10.05.2016 Dec. 01.08.2016 - TC 1617005 Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8537.10.90 SWITCH CONTROL AND MONITOR ASSEMBLIES, CONVEYOR, containerised, including ALL of the following: (a) supervisory control and data acquisition (SCADA) system, including ALL of the following; (i) input AND output cards; (ii) interface modules; (iii) ethernet switches; (iv) touch screen based human machine interface, (b) local start AND stop stations AND/OR junction boxes; (c) modular motion control drives; (d) switch boards; (e) power supplies; (f) container lights Op. 22.03.2016 Dec. 27.06.2016 - TC 1611194 8537.10.90 DIMMERS, LIGHTING, having ALL of the following: (a) load rating NOT less than 1 A per channel; (b) supply frequency NOT greater than 63 Hz; (c) supply voltage NOT greater than 250 V; (d) rail mounted Op. 23.03.2016 Dec. 22.06.2016 - TC 1611489 8537.10.90 POWER POINT CONVERSION PLUGS, remote control AND/OR sensor operated Op. 18.09.2015 Dec. 14.12.2015 - TC 1535547 8537.10.90 DISTRIBUTION BOARD CONTROL MODULES, lighting AND power outlet, voltage NOT exceeding 1 000 V, having ALL of the following: (a) automatic AND manual operation; (b) on AND/OR off sensors; (c) emergency testing timer Op. 10.08.2015 Dec. 02.11.2015 - TC 1531411 8537.10.90 SURGE ARRESTERS, having ALL of the following: (a) input voltage NOT less than 120 V and NOT greater than 240 V; (b) input frequency NOT less than 50 Hz and NOT greater than 60 Hz; (c) energy joule rating NOT less than 210 J and NOT greater than 3 020 J Op. 30.07.2015 Dec. 19.10.2015 - TC 1529894 8537.10.90 CONTROLLERS, DIGITAL OUTPUT, including ALL of the following: (a) voltage NOT greater than 240 V; (b) LCD touch screen; (c) NOT less than 4 terminal blocks; (d) USB, 9-way SUB-D AND RJ45 connectors; (e) CPU memory capacity NOT less than 128 MB Op. 31.07.2015 Dec. 19.10.2015 - TC 1529898 8537.10.90 CONTROLLERS, ROOF SUPPORT, LONGWALL MINE, assembled Op. 06.07.2015 Dec. 01.10.2015 - TC 1526361 8537.10.90 POWER DISTRIBUTION UNITS, having ALL of the following: (a) switched OR metered controls; (b) nominal output voltage NOT less than 120 V and NOT greater than 230 V; (c) maximum input current NOT less than 10 A and NOT greater than 32 A Op. 08.07.2015 Dec. 01.10.2015 - TC 1526584 8537.10.90 MANAGEMENT AND SAFETY SYSTEM, ELECTROLYSER, having ALL of the Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8537.10.90 following: (a) data acquisition unit with enclosure; (b) electrolyser communication AND alarm module with enclosure; (c) external power pack; (d) fibre optic cable AND connectors; (e) cell connection wires AND connection hardware; (f) software Op. 13.05.2015 Dec. 10.08.2015 - TC 1518250 BYPASS PANELS, having BOTH of the following: (a) output voltage NOT less than 120 V and NOT greater than 400 V; (b) maximum total current draw per phase NOT less than 10 A and NOT greater than 235 A Op. 09.06.2015 Dec. 31.08.2015 - TC 1521058 8537.10.90 VARIABLE SPEED DRIVES, PUMP, whether OR not assembled, including ALL of the following: (a) drive enclosure; (b) input operating voltage NOT less than 340 V and NOT greater than 530 V; (c) transformer; (d) short circuit protectors; (e) internal AND external fans Op. 30.01.2015 Dec. 11.05.2015 - TC 1504373 8537.10.90 CONTROL MODULES,DOWNHOLE MECHANICAL INTERVENTION TOOL, whether OR not assembled, including ALL of the following: (a) power supply; (b) temperature sensors; (c) pressure sensors; (d) power converter Op. 09.07.2014 Dec. 08.10.2014 - TC 1424101 8537.10.90 CONSOLES, ELECTRIC TRAIN, POWER AND BRAKING SYSTEM, including ALL of the following: (a) driver control handles; (b) key switch-locking; (c) directional controllers; (d) dead man mechanism Op. 29.05.2014 Dec. 25.08.2014 - TC 1418243 8537.10.90 CARTS OR CAGES OR CABINETS, STORAGE, LAPTOP AND COMPUTER TABLETS, incorporating electrical power board with timer and remote control Op. 10.04.2014 Dec. 15.07.2014 - TC 1412645 8537.10.90 PANEL BOARDS, CIRCUIT BREAKER, AC, having BOTH of the following: (a) voltage capacity NOT greater than 600 V; (b) NOT less than 4 conduit hubs Op. 03.02.2014 Dec. 21.05.2014 - TC 1404552 8537.10.90 CONTROL CABINETS, ELECTRIC GENERATING SET WITH SPARK-IGNITION INTERNAL COMBUSTION ENGINE, having a voltage capacity NOT exceeding 1 000 V Op. 13.08.2013 Dec. 15.11.2013 - TC 1327653 8537.10.90 REMOTE OPERATOR CONTROL STATIONS, RAIL MOUNTED GANTRY CRANE, whether OR not assembled Op. 26.09.2012 Dec. 30.01.2013 - TC 1236852 8537.10.90 CONTROL CONSOLES, OIL AND/OR GAS WELL EQUIPMENT, surface AND/OR subsea Op. 01.11.2012 Dec. 30.01.2013 - TC 1241988 Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8537.10.90 POWERBOARDS, having ALL of the following: (a) maximum voltage capacity NOT greater than 1 000 V; (b) surge protector; (c) inbuilt timer AND/OR remote control sensors Op. 05.04.2012 Dec. 09.07.2012 - TC 1211475 8537.10.90 MASTER CONTROL MODULES, OIL AND GAS WELL, SURFACE AND/OR SUBSEA, being programmable logic controlled, with OR without uninterruptible power supply (UPS) Op. 25.01.2012 Dec. 16.04.2012 - TC 1203002 8537.10.90 INTERFACE, TRAM DRIVERS DESK, including ALL of the following: (a) touch screen controls; (b) switches; (c) video interface Op. 06.12.2011 Dec. 06.03.2012 - TC 1140596 8537.10.90 MASTER CONTROLLERS, TRAM, including ALL of the following: (a) handle sensors; (b) start blocking push buttons; (c) dead man capacitive sensors Op. 06.12.2011 Dec. 06.03.2012 - TC 1140595 8537.10.90 DOUBLE ADAPTORS, POWER POINT, having ALL of the following: (a) maximum voltage capacity NOT greater than 1 000 V; (b) surge protector; (c) inbuilt timer AND/OR remote control sensors Op. 24.10.2011 Dec. 16.01.2012 - TC 1135623 8537.10.90 CONDUCTOR ASSEMBLIES, PHOTOVOLTAIC MODULE, having ALL of the following: (a) insulated electrical cables AND fitted electrical connections; (b) aluminium junction box, incorporating electrical terminals, bus bar AND diodes; (c) conductor rated current NOT greater than 16 A; (d) conductor rated voltage NOT greater than 1 000 V DC; (e) conductor operating temperature rating minus 40 degrees Celsius to plus 85 degrees Celsius Op. 11.10.2011 Dec. 04.01.2012 - TC 1134258 8537.10.90 DIGITAL SOFT STARTERS, electrical motor Op. 09.09.2011 Dec. 05.12.2011 - TC 1130841 8537.10.90 STATIC CHARGE STATION, ELECTRIC MOTOR VEHICLE BATTERIES, having ALL of the following: (a) input voltage NOT less than 230 V, single phase; (b) input voltage NOT greater than 400 V, 3 phase; (c) input current NOT greater than 33 A; (d) outlet charging power NOT greater than 3.7 kW per socket, single phase; (e) outlet charging power NOT greater than 11 kW per socket, 3 phase; (f) 16 A circuit breaker per outlet socket; (g) wireless modem Op. 29.06.2011 Dec. 26.09.2011 - TC 1121287 8537.10.90 CONTROL PANELS, GAS OR ELECTRIC OVEN Op. 17.06.2011 Dec. 05.09.2011 8537.10.90 - TC 1119510 POWER OUTLETS AND/OR MULTIMEDIA PORTS, AC, having power socket outlets and ANY of the following: (a) overload circuit breakers; (b) data sockets; Item 50 applies unless otherwise stated. Tariff Description =========================================================================== (c) audio jacks; (d) VGA(video graphics array) jacks; (e) LEDs(light-emitting diodes); (f) switches; (g) cables and plugs Op. 29.11.2010 Dec. 28.02.2011 - TC 1052204 8537.10.90 POWERBOARDS, 240 V, AC, having NOT less than 4 outlets Op. 22.09.2006 Dec. 03.02.2010 - TC 1005808 8537.10.90 ELECTRICAL JUNCTION BOXES, MOTOR VEHICLE, fitted with fuses AND/OR relays Op. 23.10.2009 Dec. 08.01.2010 - TC 0940026 8537.10.90 POSITION CONTROLLERS, LINEAR ACTUATOR Op. 25.10.2005 Dec. 23.01.2006 - TC 0514831 8537.10.90 PANELS, CONTROL, MOTOR VEHICLE, having BOTH of the following: (a) visual display screens; (b) controls AND/OR switches Op. 05.06.2006 Dec. 25.08.2006 - TC 0609942 8537.10.90 PANELS, FASCIA CONTROL, MOTOR VEHICLE Op. 21.08.2007 Dec. 29.10.2007 - TC 0712978 8537.10.90 BOXES, JUNCTION, stainless steel, incorporating an ethernet connection Op. 20.09.2007 Dec. 30.11.2007 - TC 0715913 8537.10.90 SIGNALISATION DEVICES, ELEVATOR, consisting of push button switching panels Op. 18.10.2007 Dec. 30.01.2008 - TC 0717805 8537.10.90 BOXES, RELAY AND FUSE, UNDER BONNET, having BOTH of the following: (a) NOT less than six relays; (b) NOT less than six fuses Op. 01.04.2008 Dec. 13.06.2008 - TC 0805098 8537.10.90 POWER BOARDS, AC, having NOT less than 4 outlets and ANY of the following: (a) power surge protectors; (b) telephone line surge protectors; (c) computer network surge protectors; (d) Universal Serial Bus (USB) hubs Op. 16.07.2007 Dec. 21.07.2008 - TC 0816730 8537.10.90 POWER CONTROL MODULE, ASPHALT PLANT Op. 05.09.2008 Dec. 28.11.2008 - TC 0829783 8537.10.90 POWERBOARDS, surge suppression AND/OR line filtration Op. 05.09.2008 Dec. 28.11.2008 - TC 0829785 8537.10.90 SURGE SUPPRESSORS, NOT less than 220 VAC and NOT greater than 250 VAC input voltage, comprising ALL of the following: (a) surge protected input; (b) NOT less than six surge protected power outlets; (c) connectors for the external connection of telecommunication equipment, videos AND/OR computers; (d) power availability and fault indicators; (e) continuous load NOT greater than 10 A (amps) Op. 12.11.2003 Dec. 18.09.2008 - TC 0829873 8537.10.90 LEADS AND CONTROL BOXES, being parts for water filled submersible Item 50 applies unless otherwise stated. Tariff Description =========================================================================== bore hole pump motors, power rating 0.25 kW to 150 kW Op. 14.07.1993 Dec. 04.03.1994 - TC 9306927 8537.10.90 CONTROLLERS, irrigation, light energized, containing no batteries and requiring no direct sunlight, capable of controlling up to and including 32 AC powered stations (valves) OR up to 24 non AC powered stations (valves) Op. 18.08.1993 Dec. 26.11.1993 - TC 9307460 8537.10.90 CONTROLLERS, irrigation, time switch, battery operated 9 V DC capable of operating between one and four linear actuator flow control valves in remote irrigation systems Op. 26.03.1993 Dec. 02.07.1993 - TC 9308971 8537.10.90 CONTROLLERS, irrigation, time switch being 9 V DC battery operated, capable of operating between one and six 24 V AC solenoid coil powered irrigation flow control valves which are independently powered by a 24 V AC transformer Op. 26.03.1993 Dec. 02.07.1993 - TC 9308983 8537.10.90 PARTS OF ISOLATORS, (intrinsically safe devices) being printed circuit boards mounted with componentry. Op. 08.03.1994 Dec. 01.07.1994 - TC 9403560 8537.10.90 CONTROLLERS, irrigation, time switch, operated by two 9 Volt batteries, for mounting on either two way or three way valves for program watering Op. 21.03.1994 Dec. 01.07.1994 - TC 9403746 8537.10.90 CONTROLLERS, manual or computer operated, having ALL of the following: (a) capable of connection to host computer via RS232 or RS485 serial communications link; (b) capable of operating between 1 and 240 remote field stations; (c) single 2 wire current loop; (d) loop back fault isolation circuitry; (e) continuous monitoring of loop circuit integrity; (f) data transfer protocol prioritising commands from controller to remote field stations over monitoring feedback reports from remote field stations Op. 28.12.1995 Dec. 10.04.1996 - TC 9600939 8537.10.90 CONTROL INTERFACES, BROADCAST EQUIPMENT AND ROUTING SWITCHERS, having ALL the following features: (a) serial ports which are fully configurable from a PC, for connection to control panels or equipment under control; (b) ethernet port for connection to a LAN base facility control system; (c) control hardware for operations in a fully automatic redundant mode; (d) relay providing alarm contact closure under fault condition Op. 01.05.1996 Dec. 02.08.1996 - TC 9606515 8537.10.90 CONTROL PANELS, BROADCAST EQUIPMENT AND ROUTING SWITCHERS, having ALL the following: (a) key switch functions which are fully programmable from a PC; (b) visual display (lamps/intelligent character displays) which provide status of equipment under its control Op. 01.05.1996 Dec. 02.08.1996 - TC 9606518 8537.10.90 COMPONENTS, COLOUR TELEVISION CAMERAS, being EITHER of the following: (a) remote control units; (b) control panels Item 50 applies unless otherwise stated. Tariff Description =========================================================================== Op. 08.05.1996 Dec. 16.08.1996 - TC 9606923 8537.10.90 CONTROLS, CLOSED CIRCUIT TELEVISION CAMERA, pan and tilt or scanner, zoom lens optional Op. 30.10.1997 Dec. 16.01.1998 - TC 9709587 8537.10.90 CONTROLS, INDUSTRIAL BURNER, incorporating firing sequence control circuitry Op. 25.02.1998 Dec. 15.05.1998 - TC 9801685 8537.10.90 CONTROLLER, JOYSTICK, VALVE OR TRANSMISSION, electric, manual, having ALL of the following: (a) panel mounted or mounted in an enclosure; (b) spring centering; (c) single, double or triple axis; (d) potentiometers or CAM operated micro switches Op. 25.02.1998 Dec. 15.05.1998 - TC 9801686 8537.10.90 CONTROL UNITS, REMOTE Op. 19.05.1998 8537.10.90 8537.10.90 Dec. 07.08.1998 - TC 9804300 MOUNTING UNITS, POWER SUPPLY Op. 10.11.1998 Dec. 22.01.1999 - TC 9809996 POWER ENTRY PANELS, having BOTH of the following: (a) surge protection; (b) power fail interrupt detection Op. 10.11.1998 Dec. 22.01.1999 - TC 9809997 8537.10.90 IRRIGATION CONTROLLERS, two wire, 1 to 42 stations Op. 29.03.2000 Dec. 09.06.2000 - TC 0003319 8537.10.90 CONTROL UNITS, TRAIN MONITORING AND COMMUNICATION, onboard Op. 10.04.2003 Dec. 27.06.2003 - TC 0304055 8537.20.90 CABLE REEL CARS, crawler mounted, including ALL of the following: (a) motorized cable reel with 80 m trailing cable; (b) 440 V isolating switchboard; (c) 11 kV switchboard; (d) 11 kV input AND 440 V output transformer; (e) control panel Op. 13.11.2015 Dec. 10.02.2016 - TC 1541544 8537.20.90 SWITCHGEAR, RING MAIN UNIT, metal enclosed, air AND/OR epoxy insulated, having a rated voltage NOT less than 3.6 kV Op. 25.09.2015 Dec. 21.12.2015 - TC 1536373 8537.20.90 RING MAIN UNITS, metal enclosure compliant with IP54, voltage rating greater than 72.5 kV, including a circuit breaker and ANY two of the following: (a) overcurrent AND earth fault relay; (b) 3 phase busbars; (c) ring cable earth switch Op. 31.07.2015 Dec. 26.10.2015 - TC 1529897 8537.20.90 SWITCHGEAR, air insulated, incorporating a vacuum circuit breaker AND/OR fuse contactor, having a voltage rating capacity NOT less than 3.6 kV Op. 23.01.2014 Dec. 21.05.2014 - TC 1403432 8537.20.90 SWITCHGEAR, SF6 gas insulated, having a rated voltage NOT less than 22 kV Op. 29.05.2012 Dec. 03.09.2012 - TC 1218355 Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8537.20.90 POWER MODULES, containerised, including ALL of the following: (a) lighting; (b) flooring; (c) transfer switch incorporating closed transition transfer; (d) power distribution board; (e) switchgear; (f) cable management system; (g) uninterruptible power supply system; (h) AC AND/OR DC power supplied air-conditioning system; (i) fire extinguishing system; (j) transient voltage surge suppression Op. 25.10.2011 Dec. 16.01.2012 - TC 1135850 8537.20.90 SWITCHBOARDS, air insulated, having ALL of the following: (a) single busbar configuration; (b) busbar rating NOT less than 1 200 A; (c) non-motorised earthing and disconnector switches; (d) rated voltage NOT less than 35 kV Op. 30.08.2010 Dec. 15.11.2010 - TC 1040125 8537.20.90 SUBSTATIONS, POWER, comprising ALL of the following: (a) air conditioners; (b) circuit breakers; (c) transformers; (d) controllers; (e) disconnecters; (f) generators; (g) meters; (h) cables; (i) reactors; (j) static variance compensators; (k) arrestors; (l) insulators; (m) steel supports; (n) battery banks; (o) chargers; (p) switches; (q) protection relays; (r) switchboards; (s) power line carrier; (t) capacitor banks; (u) counters; (v) busbars; (w) security modules; (x) footings; (y) communication modules Op. 11.10.2007 Dec. 25.10.2010 - TC 1045898 8537.20.90 SWITCHGEAR, SF 6 gas insulated, having ALL of the following: (a) rated voltage NOT less than 66 kV; (b) circuit breaker; (c) disconnect and/or earthing switches Op. 26.03.2010 Dec. 22.07.2010 - TC 1014887 8537.20.90 POWER MODULES, PASSENGER TRAIN, 1 500 V DC, having BOTH of the following: (a) rated voltage variation NOT less than 1 000 V DC and not greater than 2 100 V DC; (b) input impedance NOT greater than 400 kilohm Op. 04.06.2009 Dec. 19.11.2009 - TC 0919012 8537.20.90 SWITCH GEAR, indoor, rated voltage 66 kV or greater, SF 6 gas insulated Op. 18.06.1998 Dec. 13.08.2009 - TC 0929299 Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8537.20.90 SWITCHGEAR, SF6 INSULATED, INDOOR, metal inclosed, incorporating vacuum circuit breakers having a rated voltage NOT less than 1 000 V Op. 26.09.2006 Dec. 05.02.2007 - TC 0615053 8537.20.90 RING MAIN SWITCHGEAR, complying with International Electrotechnical Commission Standard IEC 62271-200, having BOTH of the following; (a) voltage rating NOT less than 11 kV; (b) sulphur hexafluoride (SF6) gas filled hermetically sealed enclosures, having ANY two of the following: (i) switch disconnectors and earth switches; (ii) vacuum insulated circuit breakers; (iii) sulphur hexafluoride (SF6) gas insulated circuit breakers Op. 31.08.2007 Dec. 11.11.2007 - TC 0713867 8537.20.90 ELECTRICIAL DISTRIBUTION SYSTEM, having ALL of the following: (a) sub-stations with transformers NOT greater than 220 kV; (b) cabling; (c) transmission lines; (d) steel pylons; (e) switchboard Op. 29.08.2008 Dec. 21.11.2008 - TC 0828778 8538.90.12 CONNECTOR COMPONENTS, optical fibre Op. 01.01.2007 Dec. 07.11.2006 - TC 0614740 CONNECTOR COMPONENTS, optical fibre Op. 01.01.2007 Dec. 13.11.2006 - TC 0614741 CONNECTOR COMPONENTS, optical fibre Op. 01.01.2007 Dec. 13.11.2006 - TC 0614742 CONNECTOR COMPONENTS, optical fibre Op. 01.01.2007 Dec. 13.11.2006 - TC 0614752 CONNECTOR COMPONENTS, optical fibre Op. 01.01.2007 Dec. 13.11.2006 - TC 0614755 LAMP UNITS, sealed beam, automotive Op. 01.01.1988 Dec. 01.01.1988 - TC 8532679 8538.90.14 8538.90.16 8538.90.19 8538.90.19 8539.10 8539.10 LIGHT GLOBES, filament, but NOT including ANY of the following: (a) bus light globes; (b) candle type light globes; (c) fancy round light globes; (d) general lighting service light globes; (e) locomotive headlights (non-reflective type)light globes; (f) oven light globes; (g) pilot light globes (including normal flush and pigmy); (h) reinforced construction light globes (including rough service); (i) signal light globes - ES cap (bulb dia exceeding 19 mm); (j) street series light globes; (k) traffic signal light globes (non-tungsten halogen); (l) traction light globes; (m) train light globes (bulb dia 45 mm, 50 mm or 60 mm); (n) tubular light globes, one cap (bulb dia 19 mm or greater) Op. 26.10.1989 Dec. 09.06.1995 - TC 9505481 8539.22 GLOBES, filament, oven, 220 - 240 V, 15 W, with 1/2 edison screw connection, capable of operating at 300 degrees C Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8539.22.00 8539.22.00 Op. 23.01.1991 Dec. 09.06.1995 - TC 9505448 LAMPS, FILAMENT Op. 27.05.2002 Dec. 16.08.2002 - TC 0204639 LIGHT GLOBES, filament Op. 29.05.2002 Dec. 16.08.2002 - TC 0204654 8539.29.00 GLOBES, PILOT, 3 mm size, being ANY of the following: (a) 12 V, 50 mA; (b) 1.5 V, 50 mA; (c) 3.0 V, 50 mA Op. 29.01.1999 Dec. 16.04.1999 - TC 9900690 8539.29.00 LAMPS, FILAMENT Op. 27.05.2002 Dec. 16.08.2002 - TC 0204610 LIGHT GLOBES, filament Op. 29.05.2002 Dec. 16.08.2002 - TC 0204652 LAMPS AND/OR TUBES, COMPACT FLUORESCENT Op. 23.09.2009 Dec. 11.12.2009 - TC 0935863 LAMPS, DISCHARGE, FLUORESCENT Op. 27.05.2002 Dec. 16.08.2002 - TC 0204609 TUBES, fluorescent Op. 29.05.2002 - TC 0204655 8539.29.00 8539.31.00 8539.31.00 8539.31.00 Dec. 16.08.2002 8539.32 LIGHT GLOBES, discharge, but NOT including fluorescent tubes OR ultraviolet light globes, being ANY of the following: (a) mercury; (b) sodium; (c) metal halide; (d) iodide Op. 01.07.1996 Dec. 03.07.1996 - TC 9606677 8539.32.00 LAMPS, PROJECTOR, metal halide Op. 10.06.1999 Dec. 20.08.1999 - TC 9904261 LAMPS, DISCHARGE Op. 27.05.2002 - TC 0204608 8539.32.00 Dec. 16.08.2002 8539.39 LIGHT GLOBES, discharge, xenon, NOT being fluorescent tubes or ultraviolet light globes Op. 02.03.1987 Dec. 09.06.1995 - TC 9505476 8539.39 GLOBES, radiation, deuterium Op. 01.01.1988 Dec. 09.06.1995 8539.39 - TC 9505479 TUBES, fluorescent, coloured, being ANY of the following: (a) actinic blue; (b) black; (c) blue; (d) blue-black; (e) blue-green; (f) green; (g) green-yellow; (h) orange; (i) red; (j) violet; (k) yellow, but NOT including germicidal fluorescent tubes Op. 03.08.1992 Dec. 09.06.1995 - TC 9505496 Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8539.39 LIGHT GLOBES, discharge, but NOT including fluorescent tubes OR ultraviolet light globes, being ANY of the following: (a) mercury; (b) sodium; (c) metal halide; (d) iodide Op. 01.07.1996 Dec. 03.07.1996 - TC 9606678 8539.39.00 TUBES, FLUORESCENT, red and blue mixed light Op. 09.07.1998 Dec. 11.09.1998 - TC 9805976 LAMPS, DISCHARGE Op. 27.05.2002 Dec. 16.08.2002 - TC 0204607 LIGHT GLOBES, arc Op. 01.07.1996 Dec. 01.07.1996 - TC 9601437 LAMPS, ARC Op. 27.05.2002 Dec. 16.08.2002 - TC 0204674 LIGHT GLOBES, infra-red Op. 01.07.1996 Dec. 01.07.1996 - TC 9601439 8539.39.00 8539.41 8539.41.00 8539.49 8539.49 TUBES, fluorescent, coloured, being ANY of the following: (a) actinic blue; (b) black; (c) blue; (d) blue-black; (e) blue-green; (f) green; (g) green-yellow; (h) orange; (i) red; (j) violet; (k) yellow, but NOT including germicidal fluorescent lamps Op. 01.07.1996 Dec. 01.07.1996 - TC 9601440 8539.49.00 LIGHT GLOBES, ELECTRODE CURING, air cooled, ultra violet Op. 01.07.1996 Dec. 05.01.1996 - TC 9600081 8539.49.00 GLOBES, ULTRAVIOLET, having ALL of the following specifications: (a) starting voltage NOT exceeding 1 500 RMS; (b) operating voltage (+ 20%) 160 V; (c) operating current maximum 47.5 mA; (d) peak output of 213 nm Op. 01.07.1996 Dec. 21.04.1996 - TC 9604882 8539.49.00 LAMPS, ultraviolet, leak tracer Op. 01.07.1996 Dec. 21.01.1997 - TC 9700588 8539.49.00 LAMPS, ULTRAVIOLET, but NOT including either of the following: (a) air cooled electrode curing lamps; (b) lamps with a peak output up to and including 254 nm Op. 01.07.1996 Dec. 12.04.2002 - TC 0203080 8539.90 CAPS, fluorescent lamp Op. 29.05.1984 8539.90 Dec. 29.05.1984 - TC 8438138 PARTS FOR FILAMENT LAMPS, being ANY of the following: (a) lamp caps; (b) leading-in wires; Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8540.79.00 8540.79 (c) spirals (filaments) Op. 21.09.1987 Dec. 24.11.1987 - TC 8734712 KLYSTRONS Op. 01.01.2012 Dec. 30.11.2011 - TC 1134439 VALVES OR TUBES, thermionic transmitting Op. 01.07.1996 Dec. 02.07.1996 - TC 9608378 8540.89 VALVES OR TUBES, vacuum or gas filled, but NOT including hollow cathode atomic spectral lamps Op. 08.11.1990 Dec. 13.02.1991 - TC 9009595 8543.20 GENERATORS, test pattern (test signal), television OR video, having ANY of the following: (a) vits; (b) bounce; (c) character mixing; (d) IRS; (e) pluge; (f) pulse and bar; (g) sweep and markers Op. 29.09.1986 Dec. 20.11.1986 - TC 8635241 8543.20 OSCILLATORS, crystal, temperature compensated Op. 17.06.1987 Dec. 07.09.1987 - TC 8733723 8543.20 SIGNAL (a) (b) (c) GENERATORS, being ANY of the following: data; gunn effect; pulse, frequency range exceeding 13 MHz and rise time better than 20 ns; (d) random noise; (e) shock; (f) surge OR impulse; (g) ultrasonic, power output exceeding 10 W; (h) other signal generators, but NOT including ANY of the following: (i) synchronising, pulse or waveform signal generators, of a kind used for television applications; (ii) oscillators, crystal controlled; (iii) signal generators, having an output frequency solely within the range 0.001 Hz to 13 MHz (both inclusive); (iv) television pattern generators; (v) test generators operating in solely discrete VHF bands; (vi) plug in units OR modules being EITHER of the following: - amplifier plug ins, single or multiple, single ended or differential: . sensitivity 10 mV/division bandwidth DC to 1 MHz-3dB; . sensitivity 1 mV/division bandwidth DC to 40 MHz-3dB; . sensitivity 5 mV/division bandwidth DC to 75 MHz-3dB; - time bases, non-delayed, mixed sweep or delayed sweep, solely within the range 5 ns/division to 15 s/division (both inclusive) Op. 01.01.1988 Dec. 31.10.1990 - TC 9007140 8543.20 OSCILLATORS, being EITHER of the following: (a) test wide range, but NOT including oscillators having a frequency range within 0.001 Hz to 13 MHz (both inclusive); (b) crystal controlled, having an aging rate better than 1 x 10-9/month Item 50 applies unless otherwise stated. Tariff Description =========================================================================== Op. 01.01.1988 8543.20 Dec. 31.10.1990 SIGNAL GENERATORS, FM stereo audio broadcast Op. 02.12.1991 Dec. 13.03.1992 - TC 9007141 - TC 9200018 8543.20 SIGNAL GENERATORS, timing, for control of network synchronization Op. 13.03.1992 Dec. 29.06.1992 - TC 9203111 8543.30 ELECTROPLATING MACHINES, utilising plating pens OR tools which allow partial plating of surfaces, but NOT including plating baths OR electroplating machines which utilise plating baths Op. 20.02.1984 Dec. 20.02.1984 - TC 8430544 8543.30 ELECTROLYSIS HAIR REMOVAL UNITS, battery operated Op. 15.01.1985 Dec. 15.01.1985 - TC 8439731 8543.30 ELECTROPLATING MACHINES, capable of selectively gold plating and having a variable plating depth of 0 to 20 mm Op. 02.01.1991 Dec. 14.08.1991 - TC 9100859 8543.30.00 GENERATORS, HYDROGEN GAS, electrolytic, 12 V OR 24 V Op. 07.05.2015 Dec. 27.07.2015 - TC 1517323 8543.30.00 SEAWATER ELECTRO-CHLORINATION SYSTEM, including ALL of the following: (a) pipes AND/OR pipe fittings; (b) pumps; (c) valves; (d) tanks; (e) electrolysers; (f) strainers AND/OR filters; (g) blowers; (h) transformers AND/OR rectifiers; (i) enclosure; (j) fans; (k) air filtration system; (l) electrical instrumentation modules AND/OR controllers Op. 11.08.2014 Dec. 03.11.2014 - TC 1428023 8543.30.00 SEAWATER ELECTRO-CHLORINATION PLANT, skid mounted with canopy, having ALL of the following: (a) pipes AND/OR pipe fittings; (b) pumps; (c) valves; (d) tanks; (e) electrolysers; (f) strainers AND/OR filters; (g) electrical instrumentation modules AND/OR controllers Op. 02.01.2014 Dec. 31.03.2014 - TC 1400229 8543.30.00 ANODES, MAGNESIUM ALLOY AND/OR ALUMINIUM ALLOY, DOMESTIC HOT WEATER HEATERS Op. 02.03.2009 Dec. 22.05.2009 - TC 0907148 8543.30.00 ELECTROLYSERS, MEMBRANE CELL Op. 01.01.2007 Dec. 21.11.2006 - TC 0614456 8543.30.00 ELECTROLYSERS, MEMBRANE CELL, SODIUM HYPOCHLORITE PLANT Op. 01.01.2007 Dec. 21.11.2006 - TC 0614458 8543.90.90 PARTS, HELICOPTER PILOT NIGHT VISION AND NAVIGATION HELMET, being visors Op. 02.03.2016 Dec. 16.06.2016 - TC 1608761 Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8543.90.90 PARTS, ELECTROLYSER, whether OR not assembled, being ANY of the following: (a) anodes; (b) anode electrode assemblies having ALL of the following: (i) anode; (ii)membrane; (iii)gaskets, (c) backing flanges with rollers; (d) baffles; (e) cathodes; (f) cathode electrode assemblies having ALL of the following: (i)cathode; (ii)membrane; (iii)gaskets, (g) compression rods; (h) electrode current distributors; (i) feed tubes with OR without holes; (j) fixed OR sliding ends; (k) frames; (l) headers; (m) housing; (n) insulating blocks AND/OR connections; (o) membranes; (p) pans with OR without mesh; (q) pins; (r) plates; (s) spacer posts; (t) support rails Op. 10.03.2015 Dec. 07.06.2015 - TC 1509601 8543.90.90 PARTS, ELECTROLYSER, being ANY of the following: (a) anodes; (b) backing flanges with rollers; (c) baffles; (d) cathodes; (e) compression rods; (f) electrode current distributors; (g) feed tubes with OR without holes; (h) fixed ends; (i) frames; (j) headers; (k) housings; (l) insulating blocks; (m) membranes; (n) pans with OR without mesh; (o) pins; (p) plates; (q) sliding ends; (r) spacer posts Op. 28.03.2014 Dec. 25.06.2014 - TC 1410886 PARTS, THERMAL CAMERA, being thermal detectors Op. 19.04.2011 Dec. 11.07.2011 - TC 1113035 PARTS SYNCHROTRON, being ANY of the following: (a) YAG (yttrium aluminium garnet) screens; (b) faraday cups Op. 11.08.2005 Dec. 21.10.2005 - TC 0510523 8543.90.90 8543.90.90 8543.90.90 ANODES, LEADED, having ALL of the following: (a) stainless steel plate of NOT less than 250 kg; (b) coating, consisting of ALL of the following: Item 50 applies unless otherwise stated. Tariff Description =========================================================================== 8543.90.90 (i) lead NOT less than 400 kg; (ii) tin NOT less than 3.5 percent; (iii) copper NOT less than 90 kg Op. 07.02.2006 Dec. 07.04.2006 - TC 0603416 ELECTRODES, STAINLESS STEEL Op. 09.02.2006 Dec. 18.04.2006 - TC 0603550 8543.90.90 PARTS, ELECTRO-PLATING LINE, being tinplate tungsten coated conductor rolls Op. 08.11.2006 Dec. 19.01.2007 - TC 0618385 8543.90.90 MEMBRANES, ELECTROLYSER Op. 27.07.2007 Dec. 08.10.2007 - TC 0712169 8543.90.90 ANODES, ALLOYED LEAD, containing 0.50% silver (with a tolerance of + or - 0.015%) cast moulded, grooved and punched, having ALL of the following: (a) anode plate size of 12 mm x 943 mm x 1 705 mm with a tolerance of + or - 2 mm in respect of length and width; (b) electrolytic copper header bar with a resistivity lower than 1.7593.10 to the sixth power ohm/sq cm/cm at 20 degrees C; (c) stainless steel lifting hooks Op. 25.09.1998 Dec. 18.12.1998 - TC 9808688 8543.90.90 CATHODES, ELECTROWINNING, cold rolled aluminium plate, incorporating a tapered plastic cover capable of withstanding 20% sulphuric acid to a minimum of 40 degrees C and 50 g/L zinc solution without deterioration Op. 23.10.1998 Dec. 15.01.1999 - TC 9809434 8543.90.90 ELECTRODE SUB-ASSEMBLIES, ELECTROLYSER CELL, ANODE OR CATHODE, comprising BOTH of the following: (a) gaskets; (b) control nozzle Op. 26.08.1999 Dec. 19.11.1999 - TC 9906522 8543.90.90 CATHODE PLATES, aluminium, cold rolled, with plastic edge strips Op. 22.04.2002 Dec. 12.07.2002 - TC 0203422 Item 50 applies unless otherwise stated.