EN Operating Instructions Calorifier CombiValCR (200-2000) CombiValCSR (300-2000) MultiValCRR(300-2000) MultiVal CSRR(540-2000) Dear heating system owner, You have made the right choice with the Hoval calorifier. It offers you all the advantages of state-of-the-art, economical water heating. Please read these instructions through carefully.They contain information on how to operate the calorifier and points that have to be observed. Our sales and service personnel will be happy to provide you with any further information you may require. To be filled out by the heating technician: Calorifier type Order no. Year of construction Electrical heating inset Max. permissible operating pressure in the calorifier kW 6 bar Max. permissible operating pressure in the heating system Important telephone numbers Heating contractor Plumber Electrician Gas supplier Chimney sweep 4 210 845 / 00 - 08/11 Subject to modifications Important instructions / Commissioning / Temperature setting 4 210 845 / 00 = Safety instructions: (Information for the protection of persons) Set-up and installation Please note that the calorifier may only be set up, connected and commissioned by an authorised specialist company. The heating water must also be drained completely on the heating side. Only an authorised specialist company may drain the tank and the heating system, take the heating system out of operation or put it back into operation. Modifications Modifications to the calorifier, to the water and heating connections or to the electrical connections may only be carried out by trained technicians. The safety valve and the exhaust line must not be modified in any way. Commissioning =Precautions: (instructions for the protection of the hot water system) Care and maintenance Interior Regular cleaning and desludging of the calorifier is necessary for reasons of hygiene and cost-effectiveness. The cleaning intervals will depend on the water quality, the operating temperature and the hot water consumption. Cleaning work may only be performed by the Hoval customer service or an authorised specialist company. We recommend that you conclude a maintenance contract with Hoval customer service or an authorised specialist company. Cleaning the casing Cleaning is best performed with a cloth moistened with a soap solution. Taking out of operation / frost protection If there is a frost hazard, the calorifier must be kept in operation. If it is taken out of operation, the calorifier must be completely drained. Hot water may emerge during draining! Where there is a frost hazard, it is also important to note that not only the water in the calorifier and in the hot water pipes can freeze, but also that in the cold water pipes and the armatures. For this reason, it is advisable to drain all pipes and armatures containing water. 2 Initial commissioning is carried out by the installation technician. The first time the water is heated and where the system has been switched off for longer periods, hot water and the full calorifier output only become available after expiry of the heating-up time. While the water is being heated, some water will emerge from the exhaust line of the tank safety valve. This is normal and no cause for concern. The exhaust line of the safety valve must remain open at all times. Temperature setting For reasons of economy and hygiene, we recommend that the hot water temperature is set to 60°C. A hot water temperature of 60°C prevents the formation of legionellae and ensures maximum cost effectiveness in line with the Energy Ordinance. Where the water contains high levels of calcium carbonate (hard water), the formation of limescale in the tank and the overall hot water installation and armatures is delayed. In addition, there is a danger of scalding at higher hot water temperatures. The temperature is normally set at the boiler control panel. The temperature can also be set via an adjustable thermostat installed on the calorifier (available as an accessory). If the calorifier is equipped with an electrical heating inset, the temperature is set via the thermostat dial of the electrical heating inset. In the case of combined systems, e.g. solar plants, the temperature can also be set via other control devices. Warranty / checklist in the event of faults 4 210 845 / 00 Warranty With the purchase of the Hoval calorifier, you have a comprehensive warranty in accordance with our terms of sale and warranty. Please note that this warranty only applies if the following work is performed exclusively by an authorised specialist company: - Set-up, installation, connection and commissioning - Modifications to the installation - Maintenance and cleaning (interior) and opening of the flange - Draining, taking out of operation, putting back into operation Checklist in the event of faults Fault Inspection/cause Remedy No hot water in heat generator operating mode Heat generator is not switched on Check readiness for operation and switch heat generator on Hot water energy selector switch is not set to heat generator operating mode Switch to heat generator operating mode Charging pump blocked or defective Unblock or replace charging pump (call in customer service) Electr. heating inset not switched on Switch on or switch to heating operation with electrical heating inset No power supply at electrical heating inset Check fuse, where applicable, switch on additional switch Overtemperature protection has tripped Check or replace thermostat (call in customer service) Heating flow temperature too low for hot water operation Increase heating flow temperature for hot water charging Primary water quantity too low Set charging pump to higher output Limescale deposits on heat exchanger Have cleaning and decalcification performed (call in customer service) In heating operation with electrical heating inset: Limescale on the heating rods Decalcification or replacement of the electrical heating rods (customer service) Domestic hot water temperature too low Thermostat or controller switches off too soon Readjust thermostat or controller Leakage at calorifier Sealing on maintenance flange Tighten flange screws and, where necessary, sealing (customer service) NO hot water with the electr. heating Too little hot water, heating-up time too long Please note! In the event of malfunctions, please carry out the checks listed above. If this does not remedy the fault, please call your heating contractor or Hoval customer service. 3 United Kingdom Hoval Ltd. Northgate Newark Nottinghamshire NG24 1JN Phone +44 1636 67 27 11 Fax +44 1636 67 35 32 www.hoval.co.uk Switzerland Hoval AG General Wille-Strasse 201 CH-8706 Feldmeilen Phone +41 44 925 61 11 Fax +41 44 923 11 39 www.hoval.ch Germany Hoval GmbH Karl-Hammerschmidt Strasse 45 D-85609 Aschheim-Dornach Phone +49 89 92 20 97-0 Fax +49 89 92 20 97-77 www.hoval.de Austria Hoval Gesellschaft mbH Hovalstrasse 11 A-4614 Marchtrenk Phone +43 50 365 - 0 Fax +43 50 365 - 5005 www.hoval.at Italy Hoval s.r.l. Via per Azzano San Paolo, 26/28 I-24050 Grassobbio (BG) Phone +39 035 52 50 69 Fax +39 035 52 58 58 www.hoval.it France Hoval SAS 6, rue des Bouleaux F-67100 Strasbourg Phone +33 3 88 60 39 52 Fax +33 3 88 60 53 24 www.hoval.fr Conservation of Energy Protection of the Environment