Part Number 18148
RCM–2 AIR DISTRIBUTION MANIFOLD
Part Number 18159
We Manage Heat ®
Description
The RCM–1 and RCM–2 Air Distribution Manifolds answer the need for high quality low cost manifolds. Using quality
valves and a machined polyacetal manifold ensures pressure tight integrity, ruggedness and a long dependable life. The unique
vertical mounting scheme conserves scarce shelter wall space without sacrificing convenient access.
The only difference between the RCM–1 and RCM–2 is the full-scale pressure gauge calibrations. These are 15 oz/in2
(gauge) and 15 psig repectively.
An RCM–1 or RCM–2 Air Distribution Manifold provides nine ports. Each port provides a cut off valve with 1/8" NPT female
fitting. These manifolds can be used to connect an ADH or EDH series dehydrator to as many as 8 antenna transmission lines or
other pressure system devices. Alternatively, multiple dehydrators can be connected to a pressure system to add the additional
protection offered by redundant dehydrators.
Individual valves combined with the pressure gauge permit quick identification of a leaking antenna or dehydrator.
Isolation of the leaky system permits normal operation of the remaining antennas.
For complete information describing its application, installation and features, please contact Customer Service or check on
the web at www.networketi.com.
Unpacking
Inspect the shipping container and packing material for damage. Save the shipping container and related materials until
normal operation has been established. If the unit must be returned, take care to ensure that it is packed as it was received.
SpecificationsRCM–1RCM–2
Operating pressure range
Max. pressure
Flowrate @ 0.5 psi
Operating temperature range
Storage temperature range
0-12 ounces/in2
15 ounces/in2
39 scfh (1104 lph)
0˚ to 140˚F (–18˚ to 60˚C)
0˚ to 140˚F (–18˚ to 60˚C)
0-12 psig
15 psig
39 scfh (1104 lph)
0˚ to 140˚F (–18˚ to 60˚C)
–40˚ to 140˚F (–40˚ to 60˚C)
Environmental Technology, Inc.
1850 N Sheridan Street • South Bend, IN 46628
(574)233-1202 • Fax (574)233-2152
Toll Free (800)234-4239 • Fax (888)234-4238
www.networketi.com • helpdesk@networketi.com
18152 rev C
08/12
(800) 234-4239
http://www.networketi.com
Environmental Technology, Inc.
1 of 4
INSTALLATION MANUAL
RCM–1 AIR DISTRIBUTION MANIFOLD
Model RCM–1 and RCM–2
1.000”
(25.4mm)
0.188”
(4.78mm)
0.21” dia. 2 places
(5.34mm)
Fig. 1: Photocopy template.
1.000”
0.188”
0.209” dia. 2 places
7.000”
7.750”
0.750”
0.812”
7.750”
(196.85mm)
7.000”
(177.8mm)
Fig. 2: Align template and mark center of holes
before drilling.
Port-1
Port-2
Port-3
Port-4
0.750”
(19.05mm)
Port-5
Port-6
Port-7
Port-8
0.812”
(20.62mm)
Fig. 3: Mount manifold upright with gauge at top.
2 of 4
Environmental Technology, Inc.
Fig. 4: Mounting hole layout, may be
photocopied & used as drill template.
http://www.networketi.com
(800) 234-4239
18152 rev C
08/12
Model RCM–1 and RCM–2
6
9
4
3
2
1
12
3
0
oz/in²
–
15
5
0
67 8 9
psi
10
11
12
13
14
15
+
RCM–1 Air Distribution Manifold
ETI P/N: 18148
RCM–2 Air Distribution Manifold
ETI P/N: 18159
Low Pressure
High Pressure
Port-1
Port-2
NOTE: High pressure gauge
is 1/4” NPT and requires a
1/4”-to-1/8” NPT adapter.
Port-3
Port-4
To Waveguide
Port-5
Port-6
Port-7
Port-8
Teflon Tape
ETI P/N 18051
(not included)
Brass 1/8” NPT to 1/4” Barbed
ETI P/N 18198
(not included)
Black Polyethylene Tubing
ETI P/N 18208
(not included)
Zip Tie
(Customer Supplied)
From ADH or EDH Dehydrator
Fig. 5: RCM air distribution manifold
shown in a typical configuration.
18152 rev C
08/12
(800) 234-4239
http://www.networketi.com
Environmental Technology, Inc.
3 of 4
Model RCM–1 and RCM–2
ORDERING INFORMATION
Order Number
18148
18159
Assessories
18208
16298
14583
18198
18040
23023
16725
18051
23022
Automatic Regenerative Dehydtrators
17479
17845
18136
17696
17846
17905
Non-Regenerative Dehydrators
18021
18250
17958
17963
Description
RCM–1 Air Distribution Manifold, 15 oz/in2
RCM–2 Air Distribution Manifold, 15 psig
Black Polyethylene UV resistant semi-rigid tubing, 1/4" ID, 3/8" OD
Tee male 1/4" (3) barbed connector
Elbow 1/8" NPT to 1/4" hose barb
Hose Barb 1/4" to 1/8" NPT male – straight
Hose Barb 1/4" to 1/8" NPT female –straight
Tee 1/8" NPT M-F-F
Compression Male 1/8" NPT – 3/8" OD tubing
Teflon Tape
Pressure Relief Valve, 6.5 psig, 1/8" NPT
ADH–3COM rack mount (UL 1950 & CE)
ADH–3COM wall mount (UL 1950 & CE)
ADH–3COM outdoor NEMA (UL 1950 & CE)
ADH–2A COM rack mount (UL 1950 & CE)
ADH–2A COM wall mount (UL 1950 & CE)
ADH–2A COM outdoor NEMA mount (UL 1950 & CE)
EDH–4 rack mount (UL 1950 & CE)
EDH–4 NEMA mount (UL 1950 & CE)
RCD–1 Passive Dehydrator
RCD–2 Self-Pumping Passive Dehydrator
LIMITED WARRANTY
ETI’s two year limited warranty covering defects in workmanship and materials applies. Contact Customer Service for complete
warranty information.
DISCLAIMER
Environmental Technology, Inc. makes no representations or warranties, either expressed or implied, with respect to the contents
of this publication or the products that it describes, and specifically disclaims any implied warranties of merchantability or
fitness for any particular purpose. Environmental Technology, Inc. reserves the right to revise this publication, and to make
changes and improvements to the products described in this publication, without the obligation of Environmental Technology,
Inc. to notify any person or organization of such revisions, changes or improvements.
The ETI logo, Snow Switch, Floorstat, Tracon, We Manage Heat, APS, RCU, CIT, GIT, SIT are registered trademarks of Environmental Technology, Inc.
Copyright © 2006 Environmental Technology, Inc. All rights reserved.
4 of 4
Environmental Technology, Inc.
http://www.networketi.com
(800) 234-4239
18152 rev C
08/12
Download