Versalite Wallpack VL20/VL30 Installation Instructions Warning: Please read instructions carefully before attempting to install fixture and save instructions for future reference. To avoid the risk of fire or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accordance with all applicable electrical codes. No user serviceable parts inside. • • • • • • Ensure electrical power is OFF before and during installation and maintenance. Luminaire must be connected to a wiring system with an equipment-grounding conductor. Make sure the supply voltage is the same as the rated luminaire voltage. Do not install where marked operating temperatures exceed the ignition temperature of the hazardous atmosphere. Do not operate in ambient temperatures above those indicated on the luminaire specifications. Keep lens tightly closed when in operation. • Use wire rated for at least 80°C. • Apply weatherproof silicone sealant around mounting box edges for enhanced moisture ingress protection. This is particularly important for installations on irregular wall surfaces. INSTALLATION: Junction Box Mounting Step 1 Open the back box by using philips screwdriver (FIG. 1), confirm junction box size prior to removing the gasket material for the application (FIG. 2). ONLY remove the gasket material needed for the installation. Mount back box to junction box via supplied hardware or lag mount. Utilize any junction box pairings for lag mount (Example: 5-5). Lag mount hardware provided by others. Junction Box Mounting Guide 1-1 2-2 3-3 4-4 5-5 6-6 7-7 FIG. 1 4” Square Box 4” Octagonal Box 3-1/2” Square/Octagonal Box Masonry Box 4” Round Box 2-3/4” Hole Pattern Single Gang FIG. 2 Revised 4/17/2014 580 Eastview Drive | Laurel, MS 39443 (p) 601.422.0033 | (f) 601.422.1652 | Toll-Free: 800.956.3456 www.Howard-Lighting.com 1 Step 2 Utilize twist-on connectors to make electrical connections (FIG. 3, 4). All electrical connections must remain inside back box. Fasten the wires by a provided cable tie, prior to closing and securing enclosure. Twist-on wire connector Supply Line (Black) Line (Black) LED Driver Supply Line (White) Supply Grounding (Green) Factory Wired LED to Driver Neutral (White) Box Grounding (Green) Fig. 3: Typical wiring layout Typical wiring layout Photocell* Twist-on wire connector Supply Line (Black) Line (Black) Load (Red) Line (Black) LED Driver Factory Wired LED to Driver Neutral (White) Neutral (White) Supply Line (White) Supply Grounding (Green) Box Grounding (Green) Fig. 4: Wiring Wiring layout with photocell* layout with photocell* Step 3 After Installation: Tighten enclosure screw to seal fixture. (FIG. 5) • Check if the lighting fixture is firmly mounted. • Check if the wires are connected properly. • Turn on Power: Check if the lighting fixture works properly. If not, please contact local dealer for troubleshooting. FIG. 5 * Provided by others Need help? Call 1-800.956.3456 to speak with our installation and product experts. Revised 4/17/2014 580 Eastview Drive | Laurel, MS 39443 (p) 601.422.0033 | (f) 601.422.1652 | Toll-Free: 800.956.3456 www.Howard-Lighting.com 2 LED Versalite VL20/VL30 Accessory Installation Instructions Knuckle Kit VLFL-KNC Step 1 Screw the Knuckle Kit on the back box (Fig. 1, 2) Fig. 1 Knuckle Kit Fig. 2 Step 2 Please refer to Fig.3/Fig. 4 for wiring information. Using a screwdriver, remove the screw at the knuckle of the Mounting Pole. Thread the wires through the hole of the Knuckle Kit. Photocell* Twist-on wire connector Supply Line (Black) Twist-on wire connector Supply Line (Black) Line (Black) Line (Black) LED Driver Supply Line (White) Neutral (White) Supply Grounding (Green) Box Grounding (Green) Fig. 3: Typical wiring layout Typical wiring layout Factory Wired LED to Driver Load (Red) Line (Black) LED Driver Factory Wired LED to Driver Neutral (White) Supply Line (White) Supply Grounding (Green) Neutral (White) Box Grounding (Green) Wiring layout with photocell* Fig. 4: Wiring layout with photocell* Step 3 Route electrical leads through the 1/2" NPS cover plate (supplied by others). Seal knuckle threads with sealing compound (provided by others). Secure cover plate to knuckle with lock nut (50-60 in-lbs). Make wire connection in outdoor rated junction box. Mount cover plate to junction box (Fig. 5). Fig. 5 * Provided by others Need help? Call 1-800.956.3456 to speak with our installation and product experts. Revised 4/21/2014 580 Eastview Drive | Laurel, MS 39443 (p) 601.422.0033 | (f) 601.422.1652 | Toll-Free: 800.956.3456 www.Howard-Lighting.com 1 Yoke Kit VLFL-Yoke Step 1 Screw the Mounting Stand on the back box (Fig. 6). Fig. 6 Yoke (Trunnion) Kit Step 2 Open the box back, put the wires SJTW 18AWG/3C* into the box back through the strain relief, twist the strain relief tightly (Fig. 7), refer to page 1 Fig. 3/Fig. 4 for wiring. Fig. 7 Step 3 Lock the enclosure (Fig. 8), mount the yoke (trunnion) on mounting surface, direction could be adjusted (Fig 9, 10). 180° Fig. 9 Fig. 8 Fig. 10 Caution: After Installation: Avoid luminaire mounting orientations that may lead to water collection in the fixture (Fig. 11). • Check if the lighting fixture is firmly mounted. • Check if the wires are connected properly. • Turn on Power: Check if the lighting fixture works properly. If not, please contact local dealer for troubleshooting. Fig. 11 Need help? Call 1-800.956.3456 to speak with our installation and product experts. Revised 4/21/2014 580 Eastview Drive | Laurel, MS 39443 (p) 601.422.0033 | (f) 601.422.1652 | Toll-Free: 800.956.3456 www.Howard-Lighting.com 2