vovo plaster

advertisement
VOVO PLASTER
Architecturally designed with
aesthetically pleasing results, VOVO
PLASTER encompasses a modern
alternative to T5 lighting. The lamp
positioning enables light to glow
through a secondary gull reflector,
whilst providing quality even light
through the micro linear wafer centre
panel. Performing at efficiencies above
80% LOR, VOVO PLASTER is an
energy efficient luminaire that offers
comfortable volumetric lighting.
VOVO PLASTER is wired complete
with an electronic (A2) ballast, T5
colour 840 triphosphor lamps and
1.5m 3 core 3 pin flex and plug.
Technical information
Product Code Wattage
Mounting
Plaster
Conversion Frame
Lens
Nominal Dim. (mm)
Cutout Dim. (mm)
L WD
VO-P-114-3
1x14w T5
Recessed Plaster
YES
MICRO CDP
635
335
100
605 x 305
VO-P-114-6
1x14w T5
Recessed Plaster
YES
MICRO CDP
635
635
100
605 x 605
VO-P-214-3
2x14w T5
Recessed Plaster
YES
MICRO CDP
635
335
100
605 X 305
VO-P-214-6
2x14w T5
Recessed Plaster
YES
MICRO CDP
635
635
100
605 X 605
VO-P-124-3
1x24w T5
Recessed Plaster
YES
MICRO CDP
635
335
100
605 x 305
VO-P-124-6
1x24w T5
Recessed Plaster
YES
MICRO CDP
635
635
100
605 X 605
VO-P-224-3
2x24w T5
Recessed Plaster
YES
MICRO CDP
635
335
100
605 X 305
VO-P-128-3
1x28w T5
Recessed Plaster
YES
MICRO CDP
1235
335
100
1205 x 305
VO-P-228-3
2x28w T5
Recessed Plaster
YES
MICRO CDP
1235
335
100
1205 X 305
VO-P-154-3
1x54w T5
Recessed Plaster
YES
MICRO CDP
1235
335
100
1205 X 305
VO-P-254-3
2x54w T5
Recessed Plaster
YES
MICRO CDP
1235
335
100
1205 x 305
Lens Options
Code
Wiring Options
Code
L5 Fine Ribbed Opal Lens
-L5
DSI digital dimming ballast
-D1
L7 Coarse Ribbed Opal Lens
-L7
DALI Eco digital dimming ballast
-D2
DALI Excel digital dimming ballast
-D3
1-10V Analogue dimming ballast
-D4
Emergency Single Point pack
-EM
Fused terminal block
-FTB
3000K Triphosphor Lamp
-3K
Polar Distribution Curve
IES INDOOR REPORT
PHOTOMETRIC FILENAME : VOXEL VX31402L-3.IES
POLAR GRAPH
942
706
471
235
Maximum Candela = 941.87 Located At Horizontal Angle = 0, Vertical Angle = 0
# 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.)
VO-P-128-3
The purpose of this data sheet is to provide general product information only. The product description, product specifications (including, without limitation, design, colour or materials) and other information
in this data sheet are subject to change without notice. Whilst reasonable care has been taken to ensure the correctness of this data sheet, Australume Pty Ltd and each of its directors, officers,
employees, agents and advisers disclaims all liability for loss or damage suffered or sustained as a result of any reliance on the information in this data sheet. It is the customer’s responsibility to ensure
suitability of the selected product referred to in this data sheet. Australume Pty Ltd reserves the right to discontinue this product or withdraw it from sale at any time without any prior notice or liability.
www.australume.com.au
Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc.
Calculations based on published IES Methods and recommendations, values rounded for display purposes.
Results derived from content of manufacturers photometric file.
Page 1
Download