EPT2, EPT10, & EPT10C 941071-00 Electric Power Transfer (EPT) Installation Instructions Read all Warnings Before Starting Installation! Tools for Install EPT10 EPT2 EPT10C A To ensure the maximum amount of travel in arm for cam lift hinges, install EPT so door side leaf is oriented with knuckle on top. C B Frame Leaf F D Door Leaf E EPT2 Shown G A. Frame Backbox B. Metal - #10-24 x 3/8” Flat Phillips Head Machine Screw (4) Wood - #10 x 3/4” Flat Phillips Head Wood Screw (4) C. EPT2 - Wire Connectors 12 Gauge Yellow (4) EPT10 - Wire Connectors 18 Gauge Violet (20) Note: Door backbox is beveled to match door EPT10C - Wire Connectors 18 Gauge Violet (20) D. EPT Assembly E. Metal - #10-24 x 3/4” Flat Phillips Head Machine Screw (8) Wood - #10 x 3/4” Flat Phillips Head Wood Screw (8) F. Door Backbox G. Strain Relief Customer Service 1-877-671-7011 www.allegion.com/us © Allegion 2014 Printed in U.S.A. 941071-00 Rev. 10/14-e General Information An electric power transfer (EPT) provides a wiring path from the door to the frame. These instructions assume that a factory-prepped door and frame are being used. If the door and frame have not been factory-prepped, see the included dimensioned template. Before beginning the installation, review “Specifications” and “Warnings”. Specifications Applications EPT can be used for: s$OOR Thickness - 1-3/4” minimum Note: The following specifications apply to a 1-3/4” thick door. s OPENINGWITHUPTO” butt hinges s OPENINGWITHUPTO” offset pivots s OPENINGWITH” butt hinges s OPENINGWITH” butt hinges EPT cannot be used for: s” offset pivots sLARGERTHAN” butt hinges sPOcket pivots sswing clear hinges sCENTERHUNGDOOR (center pivot) sBALANCEDDOOR Electrical Ratings %04 s TwOAWG wires s-AX. Rating:6$C!OR 6AC NEC Class 3 %04%04# s TENAWG wires s-AX2ATING:6$C, 1A Read all Warnings Before Starting Installation! 2 ! CAUTION $ONOTeXCEEDrated specifications (shown above). ! CAUTION EPT must be installed in accordance with these instructions by a qualified electrician. ! CAUTION Wiring must be in accordance with all local codes and regulations. Installation 1 Use Template from Back Page to Verify Preparation 4 Connect Wires 2 Refer to wiring information in product instructions Mount Frame Backbox A. Remove knockout from top B. Install 1/2” conduit, if used C. Pull 5” of field wiring through knockout Connectors Top Knockout (1/2”) Frame Field Wiring 5 Mount EPT Assembly Keep area under elbows free of connectors. splices, and field wiring cable 3 Mount Door Backbox A. Ensure backbox bevel matches door bevel B. Remove knockout: - from bottom for metal doors - from back for wood doors C. Pull 5” of field wiring through knockout D. Install strain relief Do not pinch wires between backbox and EPT assembly Door backbox bevel must match bevel on door Top View Door Strain Relief 6 Verify that door opens and closes properly without binding and that electrical components function Field Wiring OR Backbox is required for fire wood doors. Rear knockout must be used. Elbows must have approximately 1/2” of free motion when pulled straight out 3 4 1" 4 MIN. 1 3" 8 3" 4 11 " 32 3" 8 8 21 " 32 9 1 " 16 1" 4 3 " 4 METAL DOOR OR FRAME (SIDE VIEW) 5" 18 7 5 8" FOR DOOR 1" 4 5" 8 FOR FRAME REINFORCEMENT .060" (16 GA.) MINIMUM RECOMMENDED 6" BELOW UPPER HINGE OF EPT IN DOOR. OF EPT IN FRAME MUST ALIGN WITH 7" 8 FROM OUTSIDE FACE OF DOOR DOOR (OPEN 180 ) 3 3 4 " MAX. WHEN INSTALLED *ALL DIMENSIONS ARE TYPICAL FRAME METAL: #10-24 TAPPED HOLE (12 PLCS) WOOD: HOLES PREPARED DURING INSTALL. 5" 8 WOOD DOOR OR FRAME (SIDE VIEW) 1 5" 8 DIA. THRU TO WIRE CHANNEL 1" DIA. 1" X 4 DEEP Template Note: This drawing is not to scale