Read all Warnings Before Starting Installation!

advertisement

EPT2, EPT10,
& EPT10C
941071-00
Electric Power Transfer (EPT)
Installation Instructions
Read all Warnings Before Starting Installation!
Tools for Install
EPT10
EPT2
EPT10C
A
To ensure the maximum amount of
travel in arm for cam lift hinges, install
EPT so door side leaf is oriented with
knuckle on top.
C
B
Frame Leaf
F
D
Door Leaf
E
EPT2 Shown
G
A. Frame Backbox
B. Metal - #10-24 x 3/8” Flat Phillips Head Machine Screw (4)
Wood - #10 x 3/4” Flat Phillips Head Wood Screw (4)
C. EPT2 - Wire Connectors 12 Gauge Yellow (4)
EPT10 - Wire Connectors 18 Gauge Violet (20)
Note: Door backbox is
beveled to match door
EPT10C - Wire Connectors 18 Gauge Violet (20)
D. EPT Assembly
E. Metal - #10-24 x 3/4” Flat Phillips Head Machine Screw (8)
Wood - #10 x 3/4” Flat Phillips Head Wood Screw (8)
F. Door Backbox
G. Strain Relief
Customer Service
1-877-671-7011
www.allegion.com/us
© Allegion 2014
Printed in U.S.A.
941071-00 Rev. 10/14-e
General Information
An electric power transfer (EPT) provides a wiring path from the door to the frame.
These instructions assume that a factory-prepped door and frame are being used. If the door and frame have not
been factory-prepped, see the included dimensioned template.
Before beginning the installation, review “Specifications” and “Warnings”.
Specifications
Applications
EPT can be used for:
s$OOR Thickness - 1-3/4” minimum
Note: The following specifications apply to a
1-3/4” thick door.
s OPENINGWITHUPTO” butt hinges
s OPENINGWITHUPTO” offset pivots
s OPENINGWITH” butt hinges
s OPENINGWITH” butt hinges
EPT cannot be used for:
s” offset pivots
sLARGERTHAN” butt hinges
sPOcket pivots
sswing clear hinges
sCENTERHUNGDOOR
(center pivot)
sBALANCEDDOOR
Electrical Ratings
%04
s TwOAWG wires
s-AX. Rating:6$C!OR
6AC NEC Class 3
%04%04#
s TENAWG wires
s-AX2ATING:6$C, 1A
Read all Warnings Before Starting Installation!
2
! CAUTION
$ONOTeXCEEDrated specifications (shown above).
! CAUTION
EPT must be installed in accordance with these instructions by a qualified electrician.
! CAUTION
Wiring must be in accordance with all local codes and regulations.
Installation
1 Use Template from Back Page to Verify Preparation 4 Connect Wires
2
Refer to wiring information
in product instructions
Mount Frame Backbox
A. Remove knockout from top
B. Install 1/2” conduit, if used
C. Pull 5” of field wiring through knockout
Connectors
Top Knockout
(1/2”)
Frame
Field Wiring
5
Mount EPT Assembly
Keep area under elbows free
of connectors. splices, and
field wiring cable
3
Mount Door Backbox
A. Ensure backbox bevel matches door bevel
B. Remove knockout: - from bottom for metal doors
- from back for wood doors
C. Pull 5” of field wiring through knockout
D. Install strain relief
Do not pinch wires
between backbox and
EPT assembly
Door backbox bevel must
match bevel on door
Top View
Door
Strain Relief
6
Verify that door opens and closes properly without
binding and that electrical components function
Field Wiring
OR
Backbox is required for
fire wood doors. Rear
knockout must be used.
Elbows must have
approximately 1/2”
of free motion when
pulled straight out
3
4
1"
4
MIN.
1
3"
8
3"
4
11 "
32
3"
8
8
21 "
32
9
1 "
16
1"
4
3 "
4
METAL
DOOR OR FRAME
(SIDE VIEW)
5"
18
7
5
8"
FOR DOOR
1"
4
5"
8
FOR FRAME
REINFORCEMENT
.060" (16 GA.)
MINIMUM
RECOMMENDED 6" BELOW
UPPER HINGE
OF EPT IN DOOR.
OF EPT IN FRAME MUST ALIGN
WITH
7"
8 FROM OUTSIDE
FACE OF DOOR
DOOR
(OPEN 180 )
3
3 4 " MAX.
WHEN INSTALLED
*ALL DIMENSIONS ARE TYPICAL
FRAME
METAL:
#10-24 TAPPED
HOLE (12 PLCS)
WOOD:
HOLES PREPARED
DURING INSTALL.
5"
8
WOOD
DOOR OR FRAME
(SIDE VIEW)
1
5"
8 DIA. THRU TO
WIRE
CHANNEL
1" DIA.
1"
X 4 DEEP
Template
Note: This drawing is not to scale
Download