Adaptive architectural lighting Adaptive architectural lighting systems systems IES File Performance Summary The performance data in black text is confirmed through third party testing (see the following Light Laboratory, Inc. report for details). The performance data in grey text is calculated by Vode. For reference only. ZipTwo LED - Zipper board™ with 40° Diffuse Lens and Micro Baffle, Standard Output ZipTwo LED, 48”, 3500K, Zipper board with 40° diffuse lens and micro baffle, standard output 707-Z2-4-48-X-X-X-X-Z-SO-35-S1-X-X Efficacy - Lumens per Watt Total Lumens, 4’ rail length (1219mm) Lumens per foot (305mm) Input Power (W), 4’ rail length (1219mm) Watts per foot (305mm) CRI (>80min., 85 avg.) 2700K 3000K 3500K 4000K 48 1355 338 28 7 - 50 1412 353 28 7 - 53 1471 367 28 7 84 54 1530 382 28 7 - 10/28/15 Report No: L101503201R01 Date: 11/9/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 L101503201R01 Report No: Report Prepared For: Model Number: Test: NVLAP LAB CODE 200927-0 Vode Lighting 1206 E MacArthur Street Suit 3, Sonoma, CA 95476 707-Z2-48-Z-SO-S1-AL Electrical and Photometric tests Standards Used: Appropriate part or all test guidelines were used for test performed: IESNA LM79: 2008 Approved Methods for Electrical and Photometric Measurements of Solid-State Lighting Products ANSI NEMA ANSLG C78.377: 2008 Specification of the Chromaticity of Solid State Lighting Products ANSI C82.77:2002: Harmonic Emission Limits-Related Quality Requirements for Lighting Equipment Description of Sample: Client submitted the sample. Catalog number is 707-Z2-48-Z-SO-S1-AL. Received in working and undamaged condition. No modifications were necessary. Testing Condition: Fixture is tested with no special conditions. Sample Arrival Date: 11/16/15 Date of Tests: 10/14/15 Seasoning of Sample: No seasoning was performed in accordance with IESNA LM-79. - 10/19/15 Equipment List Equipment Used Chroma Programmable AC Source Yokogawa Digital Power Meter Xitron Power Analysis System BK Precision DC Power Supply Fluke Digital Thermometer LLI Type C Goniophotometer System LLI 2M Sphere LLI Spectroradiometer Model No Stock No Calibration Due Date 61604 WT210 2503AH 1747 52k/J RMG-C-MKII 2MR97 SPR-3000 PS-AC02 MT-EL06-S1 MT-EL01 PSDC-04 MT-TP02-GC CD-LL04-GC CD-SN03-S2 MT-SC01-S2 -11/10/15 10/20/15 01/08/16 01/05/16 --Before Use *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 1 of 4 Report No: L101503201R01 Date: 11/9/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 Test Summary Manufacturer: Model Number: Driver Model Number: Total Lumens: Input Voltage (VAC/60Hz): Input Current (Amp): Input Power (W): Input Power Factor: Current ATHD @ 120V(%): Current ATHD @ 277V(%): Efficacy: Color Rendering Index (CRI): Correlated Color Temperature (K): Chromaticity Coordinate x: Chromaticity Coordinate y: Ambient Temperature (oC): Stabilization Time (Hours): Total Operating Time (Hours): Off State Power(W): NVLAP LAB CODE 200927-0 Vode Lighting 707-Z2-48-Z-SO-S1-AL MEAN WELL HLG-40H-36A 1471.73 120.00 0.23 27.92 0.99 9% N/A 53 84 3537 0.4052 0.3951 25.0 0:40 1:40 0.00 FIG. 1 LUMINAIRE *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 2 of 4 Report No: L101503201R01 Date: 11/9/2015 Percent Output 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Spectral Power 1.0 0.8 0.6 0.4 0.2 0.0 380 Wavelength W/m2nm 380 390 400 410 420 430 0.0010 0.0009 0.0016 0.0054 0.0224 0.0766 CRI & CCT x 0.4052 y 0.3951 u' 0.2339 v' 0.5131 CRI 83.70 CCT 3537 Duv 0.00193 R Values R1 81.84 R2 90.55 R3 96.40 R4 80.64 R5 80.97 R6 86.30 R7 86.81 R8 66.47 R9 18.95 R10 76.91 R11 78.15 R12 62.62 R13 83.90 R14 97.92 430 440 450 460 470 480 490 500 480 530 0.2468 0.6954 0.5887 0.4116 0.2946 0.3148 0.3959 510 520 530 540 550 560 570 580 Wavelength(nm) 0.4830 0.5556 0.6264 0.6977 0.7698 0.8436 0.8981 580 590 600 610 620 630 640 630 680 0.9698 0.9979 1.0000 0.9840 0.9109 0.8279 0.7339 650 660 670 680 690 700 710 730 0.6284 0.5194 0.4174 0.3312 0.2575 0.1967 0.1481 780 720 730 740 750 760 770 780 0.1073 0.0790 0.0579 0.0421 0.0299 0.0220 0.0161 CIE 1931 Chromaticity Diagram Y 0.9 520 0.8 530 540 510 0.7 550 560 0.6 570 500 0.5 580 590 0.4 0.4052, 0.3951 0.3 490 600 610 620 630 640 650 700 0.2 480 0.1 470 460 0 0 0.1 440 430 380 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 X *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 3 of 4 Report No: L101503201R01 Date: 11/9/2015 8165 E Kaiser Blvd. Anaheim, CA 92808 p. 714.282.2270 f. 714.676.5558 NVLAP LAB CODE 200927-0 Test Methods Photometric Measurements - Goniophotometer A Custom Light Laboratory Type C Rotating Mirror Goniophotometer was used to measure candelas(intensity) at each angle of distribution as defined by IESNA for the appropriate fixture type. Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Spectral Measurements - Integrating Sphere A Sensing Spectroradiometer SPR-3000, in conjunction with Light Laboratory 2 meter integrating sphere was used to measure chromaticity coordinates, correlated color temperature(CCT) and the color rendering index(CRI) for each sample. Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Disclaimers: This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of Federal Government. Report Prepared by : Keyur Patel Test Report Released by: Test Report Reviewed by: Jeff Ahn Engineering Manager Steve Kang Quality Assurance *Attached are photometric data reports. Total number of pages: 9 *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 4 of 4 IES INDOOR REPORT PHOTOMETRIC FILENAME : L101503201.IES DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] L101503201 [TESTLAB] LIGHT LABORATORY, INC. [ISSUEDATE] 10/19/2015 [MANUFAC] VODE LIGHTING [LUMCAT] 707-Z2-48-Z-SO-S1-AL [LUMINAIRE] 707 ZipTwo, 48", SO, 3500k, 40° with Micro Baffle [MORE] SIZE: 1.25"L. X 48"W. X 0.25"H. [BALLASTCAT] MEAN WELL HLG-40H-36A [LAMPPOSITION] 0,0 [LAMPCAT] N/A [OTHER] INDICATING THE CANDELA VALUES ARE ABSOLUTE AND [MORE] SHOULD NOT BE FACTORED FOR DIFFERENT LAMP RATINGS. [INPUT] 120VAC, 27.92W [TEST PROCEDURE] IESNA:LM-79-08 CHARACTERISTICS Lumens Per Lamp Total Lamp Lumens Luminaire Lumens Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Total Luminaire Watts Ballast Factor CIE Type Spacing Criterion (0-180) Spacing Criterion (90-270) Spacing Criterion (Diagonal) Basic Luminous Shape Luminous Length (0-180) Luminous Width (90-270) Luminous Height N.A. (absolute) N.A. (absolute) 1472 N.A. 53 27.92 1.00 Direct 0.86 1.18 1.02 Rectangular 0.01 ft 4.00 ft 0.00 ft LUMINANCE DATA (cd/sq.m) Angle In Degrees Average 0-Deg Average 45-Deg Average 90-Deg 45 55 65 75 85 46948 34704 31724 28835 20883 93234 56631 42246 34268 23536 177200 122621 82750 57141 33314 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 1 IES INDOOR REPORT PHOTOMETRIC FILENAME : L101503201.IES CANDELA TABULATION 0.0 1.0 3.0 5.0 7.0 9.0 11.0 13.0 15.0 17.0 19.5 22.5 25.5 29.0 33.0 37.5 42.5 47.5 55.0 65.0 75.0 85.0 90.0 Vert. Angles 0.0 1.0 3.0 5.0 7.0 9.0 11.0 13.0 15.0 17.0 19.5 22.5 25.5 29.0 33.0 37.5 42.5 47.5 55.0 65.0 75.0 85.0 90.0 0 993.03 993.31 989.63 984.06 973.43 958.35 938.38 910.28 875.83 831.01 764.09 667.26 560.24 436.59 312.08 211.74 142.50 104.46 74.04 49.87 27.76 6.77 0.00 5 993.03 993.31 989.80 984.06 973.56 935.56 938.64 910.92 876.77 832.26 765.89 669.79 562.89 439.46 314.74 213.62 143.79 105.23 74.46 50.00 27.76 6.86 0.00 10 993.03 993.27 989.88 983.97 973.77 936.58 939.58 912.51 878.92 835.64 770.78 676.56 571.16 448.37 323.22 220.05 147.86 107.63 75.36 50.43 27.94 6.90 0.00 15 993.03 993.35 989.88 984.31 974.33 937.78 941.00 914.82 882.60 840.95 778.57 687.19 583.89 462.59 336.67 230.42 154.54 111.78 77.21 51.11 28.19 6.90 0.00 20 993.03 993.44 990.01 984.48 974.84 939.84 943.10 918.03 887.91 848.24 788.64 701.45 602.14 482.86 355.95 245.71 164.65 117.61 80.08 52.10 28.54 7.03 0.00 25 993.03 993.22 989.97 984.87 975.57 942.41 945.45 922.10 893.44 856.59 801.20 719.45 624.80 508.39 381.23 266.24 178.71 126.26 84.02 53.51 29.05 7.07 0.00 30 993.03 993.40 990.18 985.13 976.43 944.64 948.07 926.13 900.04 865.89 815.25 739.63 650.12 538.30 412.47 292.54 197.04 138.09 89.33 55.44 29.65 7.20 0.00 35 993.03 993.44 990.35 985.51 977.29 948.07 951.07 930.80 906.94 875.83 829.77 760.84 678.66 572.36 448.88 325.62 221.72 153.60 96.96 58.05 30.46 7.24 0.00 40 993.03 993.44 990.35 986.20 978.27 951.32 953.59 935.51 913.88 885.68 844.43 782.34 708.39 610.15 489.80 364.65 252.61 174.34 107.37 61.65 31.58 7.46 0.00 60 993.03 993.61 991.00 987.78 981.79 963.49 963.92 951.15 936.71 918.16 891.98 853.29 806.38 741.73 654.79 546.53 423.09 311.48 186.16 91.69 40.96 8.70 0.00 65 993.03 993.57 991.30 988.08 982.47 965.55 966.10 954.15 940.74 923.52 899.65 864.05 821.50 762.33 683.50 582.30 462.89 349.27 211.65 103.26 44.73 9.21 0.00 70 993.03 993.57 991.25 988.34 983.28 967.95 967.56 956.12 943.70 927.63 905.14 871.89 832.00 776.56 702.48 606.64 490.87 377.38 233.72 113.62 48.33 9.68 0.00 75 993.03 993.65 991.34 988.60 983.67 969.66 968.76 957.75 945.92 930.67 909.12 877.24 839.24 786.46 714.86 621.98 508.74 395.84 248.97 121.94 51.46 10.15 0.00 80 993.03 993.52 991.51 988.77 984.06 971.72 969.49 959.16 947.60 932.60 911.95 880.71 843.57 791.85 721.20 629.95 517.95 404.84 257.41 126.91 53.64 10.54 0.00 85 993.03 993.61 991.51 988.85 984.23 973.26 970.05 959.85 948.67 933.80 913.15 882.51 845.97 794.60 724.72 633.46 521.38 408.70 260.67 129.26 54.76 10.75 0.00 90 993.03 993.82 991.51 988.94 984.31 978.23 970.43 960.15 948.92 934.01 913.79 882.94 846.70 795.20 725.87 634.36 522.53 409.60 261.61 130.08 55.01 10.80 0.00 45 993.03 993.44 990.53 986.54 979.21 954.06 956.55 939.80 920.47 895.37 858.26 803.29 736.89 647.00 533.24 408.95 289.16 201.28 120.82 66.41 32.99 7.63 0.00 Horizontal Angles 50 993.03 993.52 990.70 986.97 980.07 957.32 959.29 943.95 926.60 903.89 871.67 822.70 763.79 682.99 577.72 456.08 332.13 234.19 138.43 73.14 35.05 7.93 0.00 55 993.03 993.18 991.00 987.40 981.01 960.06 961.73 947.64 932.13 911.69 882.94 839.20 786.88 715.46 619.15 503.55 378.36 271.89 160.67 81.58 37.70 8.23 0.00 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 2 IES INDOOR REPORT PHOTOMETRIC FILENAME : L101503201.IES ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-20 0-30 0-40 0-60 0-80 0-90 10-90 20-40 20-50 40-70 60-80 70-80 80-90 90-110 90-120 90-130 90-150 90-180 110-180 0-180 333.58 649.90 916.11 1276.62 1444.83 1471.73 1396.02 582.53 819.87 468.57 168.21 60.16 26.90 0.00 0.00 0.00 0.00 0.00 0.00 1471.73 N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. 22.70 44.20 62.20 86.70 98.20 100.00 94.90 39.60 55.70 31.80 11.40 4.10 1.80 0.00 0.00 0.00 0.00 0.00 0.00 100.00 Total Luminaire Efficiency = N.A.% ZONAL LUMEN SUMMARY Zone Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 75.71 257.87 316.32 266.21 237.35 123.17 108.05 60.16 26.90 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 3 IES INDOOR REPORT PHOTOMETRIC FILENAME : L101503201.IES COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 0 1 2 3 4 5 6 7 8 9 10 119 119 119 119 110 106 103 99 102 95 89 84 95 86 79 73 88 78 70 64 82 71 63 57 77 65 57 52 72 60 52 47 68 56 48 43 64 52 44 39 60 48 41 36 116 116 116 116 108 104 101 98 100 93 88 84 92 84 78 73 86 77 69 64 80 70 63 57 75 64 57 51 70 59 52 47 66 55 48 43 62 51 44 39 59 48 41 36 111 111 111 100 97 95 90 85 82 81 76 71 74 68 63 68 61 57 62 56 51 58 51 46 54 47 42 50 44 39 47 40 36 106 106 106 96 94 92 87 83 80 79 74 70 72 67 62 66 60 56 61 55 51 56 50 46 52 47 42 49 43 39 46 40 36 102 102 102 92 91 89 84 81 78 76 72 69 70 65 62 64 59 55 59 54 50 55 50 46 51 46 42 48 43 39 45 40 36 100 87 76 67 60 54 48 44 40 37 34 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 4 IES INDOOR REPORT PHOTOMETRIC FILENAME : L101503201.IES POLAR GRAPH 994 745 497 3 248 1 2 Maximum Candela = 993.82 Located At Horizontal Angle = 90, Vertical Angle = 1 # 1 - Vertical Plane Through Horizontal Angles (0 - 180) # 2 - Vertical Plane Through Horizontal Angles (90 - 270) (Through Max. Cd.) # 3 - Horizontal Cone Through Vertical Angle (1) (Through Max. Cd.) Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 5