FLEXIBLE CONDUIT TYPES
Type UA
Type CNP
UA
EFST
EF
HTUA
HC
HCX
ZHUA
CW
OR
EFL
MTC
STAINLESS STEEL CONNECTORS
DE-710
DSL
RWS
RWA
FireT ech™
NMUA
NMUA CONNECTORS
CNP
SHIELDTITE®
FG
NWC
SL
UI
PACKAGING & CUTTING INSTRUCTIONS
CHEMICAL RESISTANCE CHART
31
32
33
34-35
25
26
27
29
30
19
20
21
22
23
24
11
13
14
15
16
17
18
4-5
6
7
8
9
10
2
Type MTC Type EF
CAT-02-130901
SHIELDTITE ®
ANAMET Electrical, Inc.
AN ANAMET COMPANY
®
The American Metal Hose Company was incorporated in 1908 as an outlet for brass mill products of The American Brass Company. Operations were located at South Main Street and Jewelry Street in Waterbury, Connecticut.
In January 1922, the Anaconda Mining Company purchased The American
Brass Company. The Atlantic
Company (ARCO) acquired The
Anaconda Company including The American Brass Company in 1977.
The origins of SEALTITE ® are directly connected to the development of the
liquid-tight
electrical conduit for the machine tool industry in
1942. The
Underwriters Laboratories approval for SEALTITE ® made by
American Metal Hose occurred in April, 1949.
In March 1984, the Anaconda Metal Hose Division was sold by ARCO to a group of private and management investors under the name of Anamet
Inc. Global operations included plants in Waterbury, Connecticut; Mattoon,
Illinois; Colborne, Ontario, Canada; Amsterdam, The Netherlands; Hinkley,
Leichestshire, England and Mexico City, Mexico.
In March 1993, Anamet Electrical, Inc. was organized as a Delaware corporation. The company currently employs over 100 people operating on a three shift basis in Mattoon, Illinois. The company is located on Interstate 57 and Route 16 on 31 acres with 230,400 square feet of space.
Anamet Electrical, Inc. is a leading worldwide supplier of SEALTITE ®
liquid-tight electrical wiring conduit. The company is known for its broad range of high quality conduit used in applications ranging from machine tools, computer wiring, of
furniture, nuclear power plants, mass-transit vehicles, military shielding and industrial construction.
3 ANAMET Electrical, Inc.
CAT-03-130901
Anaconda SEALTITE ®
Product Type Pg
UA UL Listed CSA Approved
Construction
Hot Dipped Zinc Galvanized Steel Core
Polyvinyl Chloride Cover
6 Direct Burial and in Concrete: 3/8" thru 4"
Size Range: 3/8” thru 4” - Black or Gray
Other Colors Upon Request
EFST Extra Flexible
EF General Construction
HTUA High Temperature
HC High Low Temperature
HCX Extreme High Low
Temperature
ZHUA Zero Halogen
CW Computer Blue
OR Oil Resistant
EFL Corrosion Resistant
Aluminum
MTC
Machine Tool Conduit
Stainless Steel
Connectors
Application
Where UL Listing is Required and
Conduit Grounding is Necessary
Temperature Range: -4°F to +140°F
(-20°C to +60°C)
7
Hot Dipped Zinc Galvanized Steel Core
Cord Packing
Polyvinyl Chloride Cover
Size Range: 1/4" thru 6" - Black or Gray
Hot Dipped Zinc Galvanized Steel Core
8 Polyvinyl Chloride Cover
Size Range: 3/8" thru 2" - Gray
Hot Dipped Zinc Galvanized Steel Core
Special Polyvinyl Chloride Cover for
9 Temperature Extremes
Direct Burial and in Concrete: 3/8" thru 4"
Size Range: 3/8" thru 4"- Black or Gray
Hot Dipped Zinc Galvanized Steel Core
10
EFST Core Design with Special Polyvinyl
Chloride Cover for Temperature Extremes
Size Range: 3/8" thru 4"- Black or Gray
Hot Dipped Zinc Galvanized Steel Core
EFST Core Design with Special
11 Thermoplastic Rubber Cover for Extreme
Temperatures
Size Range: 3/8" thru 4"- Black
Hot Dipped Zinc Galvanized Steel Core with
Bonding Wire thru 1-1/4"
13 Special Zero Halogen Cover
Size Range: 3/8" thru 4"- Black
Hot Dipped Zinc Galvanized Steel Core with
Polyvinyl Chloride Cover
14 Direct Burial and in Concrete: 1/2" thru 3"
Size Range: 1/2" thru 3"
Other Colors Upon Request
15
Hot Dipped Zinc Galvanized Steel Core
EFST Core Design with Special Oil
Resistant Polyvinyl Chloride Cover
Size Range: 3/8" thru 4" - Black or Gray
16
Lightweight Corrosion Resistant Aluminum
Core
Polyvinyl Chloride Cover
Size Range: 3/8" thru 4"- Gray
Hot Dipped Zinc Galvanized Steel Core
17 Polyvinyl Chloride Cover
Size Range: 3/8" thru 2"- Black
4 piece Stainless Steel Type 304 fitting
Excellent corrosion resistance and strength
18 Offered in Straight and 90°
Size Range: 3/8" thru 1"
For Vibration, Movement, Crossover
Connections and Tight Bends
Temperature Range: -4°F to +140°F
(-20°C to +60°C)
Designed for General Construction
Grade Applications
Temperature Range: -4°F to +140°F
(-20°C to +60°C)
Ideal for Environments with Extreme
Temperatures and UL Listing is
Required
Temperature Range: -51°F to +221°F
(-46°C to +105°C)
High and Low Temperature
Environments
Temperature Range: -51°F to +221°F
(-46°C to +105°C)
Where Flexibility is Required in Extreme
Temperature Environments
Temperature Range: -94°F to +392°F
(-70°C to +200°C)
For Restricted or Self-Contained
Ventilation Areas
Temperature ranges -40°F to + 176°F
(-40°C to +80°C)
Computer Wiring Meets Requirements of NEC
Temperature Range: -4°F to +140°F
(-20°C to +60°C)
Where Exposure to Cutting Oils Occur
Temperature Range: -9°F to +221°F
(-23°C to +105°C)
Where the Atmosphere is Corrosive and added Flexibility and Crush Strength is
Important
Temperature Range: -4°F to +140°F
(-20°C to +60°C)
Extra Flexible. For Use in Machine
Centers and Robotics
Temperature Range: -4°F to +140°F
(-20°C to +60°C)
Connectors can be installed with all
Anaconda Sealtite® Liquid tight flexible metal conduit.
Approved for both exposed and concealed locations.
Temperature Range: -49°F to +221°F
(-45°C to +105°C)
Certifications
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
ANAMET Electrical, Inc. 4 CAT-ID1-130901
Anaconda SEALTITE ®
Product Type Pg Construction
DE-710 Hot Dipped Zinc Galvanized Steel Core
19 Unpacked
Size Range: 5/16” thru 3/4”
DSL Hot Dipped Zinc Galvanized Steel Core
20 Unpacked
Size Range: 3/16” thru 3/4”
RWS Greenfield
21
Interlocked Zinc Coated Strip Steel
Size Range: 3/8” thru 4”
RWA Greenfield
Lightweight Aluminum
22 Smooth Inside and Outside
Size Range: 3/8” thru 4”
Application
Extra Flexible
Extra Strength
+450°F Maximum Temperature
Ideal for Applications Where Tight Bends are Required.
+450°F Maximum Temperature
Flexible with High Crush Resistance Meets
Requirements of UL1 and NEC 348
+450°F Maximum Temperature
Flexible with High Crush Resistance Meets
Requirements of UL1 and NEC 348
+500°F Maximum Temperature
23
FireT ech™ is offered in various options Sleeve, Wrap, Tape and Sheet. FireTech™ is the perfect insulator in steel mills, glass manufacturers, and other places where conduit is exposed to fire, heat and molten splash. Built from high bulk fiberglass and coated with a thick covering of iron oxide red silicone rubber, FireT ech™ can take continuous exposure to temperatures of 500° F and shed molten slag as hot as 2,000°F
NMUA General
Purpose
NMUA CONNECTORS
CNP Extra Flexible
SHIELDTITE ® EMI/RFI
FG Food Grade
NWC Nuclear Conduit
24
25
26
27
Smooth Inner Core Polyvinyl
Chloride Cover Type B Non-
Metallic Conduit
Size Range: 3/8” thru 2” - Gray
T ype Nylon 66 Construction with “O” Ring and Steel Lock Nut
Direct Burial and in Concrete
Size Range: 3/8” thru 2” - Gray
Smooth Inner Core
Nylon Braided Reinforcement
Type A Non-Metallic Conduit
Size Range: 3/8” thru 2” - Orange or Gray
Special Bronze core With Special
Polyvinyl Chloride Cover
Size Range: 3/8” thru 4”- Gray
Military Standard: MIL-STD 1310D
Hot Dipped Zinc Galvanized Steel Core
Flexible PVC jacket formulated for food
29 and beverage applications per FDA
CFR21 and NSF 51 requirements.
Size Range: 3/8” thru 2”
30
Hot Dipped Zinc Galvanized Steel Core with Bonding Wire Through 11/4”
Special Radiation Resistant Cover
Size Range: 3/8” thru 4” - Black
SL Square Locked
31
Type 302 Stainless Steel Core
Size Range: 1/8” thru 5/8”
UI Fully Interlocked
Fully Interlocked Type 302 Stainless Steel
32 Core
Size Range: 5/32” thru 1/2”
General Purpose
Non-Metallic-Smooth Inner/Outer Wall
Temperature Range: of 17˚F to +176˚F
(27˚C to +80˚C).
Type B LFNC Straight and 90° Connectors
Temperature Range: 40˚F to +212˚F
(40˚C to +100˚C).
Where Abrasion or Physical Abuse are
Factors, Constant Flexing or Movement
Temperature Range: -4°F to +140°F
(-20°C to +60°C)
For High Level RFI and EMI Shielding
Temperature Range: -51°F to +221°F
(-46°C to +105°C)
NSF Certified to NSF/ANSI 169 for special purpose food equiptment or devices.
Ideal for wash down and food processing
Temperature Range: -4°F to +140°F
(-20°C to +60°C)
Nuclear Application or Where Radiation
Protection is Necessary
Temperature Range: -40°F to +192°F
(-40°C to +89°C)
Flexible with High Crush and Corrosion
Resistance
1800°F Maximum Temperature
Flexible with High Crush and Corrosion
Resistance
Product Will Not Spring Open or Unwind
1800°F Maximum Temperature
Certifications
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
RoHS WEEE
ANAMET Electrical, Inc.
CAT-ID2-130901 5
Anaconda SEALTITE ®
UL Listed, CSA Certified
Liquid-Tight Flexible Metal Conduit (LFMC)
Construction
• Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance.
• Durable, sunlight resistant and flame retardant thermoplastic PVC jacket that resists heat, oil and chemical breakdown.
Installation
• Conduit used with standard liquid-tight connector for easy installation. IP 66/67 Rated when installed with approved connectors.
• Approved for both exposed and concealed locations.
Rated for temperature ranges -4ºF to + 140ºF (-20ºC to +60ºC).
• Approved as an equipment grounding conductor in sizes 3/8" through 1-1/4" if the total grounding path is 6 ft. or less and the circuit conductors are protected by over 20 amps for 3/8" and 1/2" and 60 amps or less for
3/4" through 1-1/4".
• Suitable for use in hazardous locations per NEC
Articles 501 Class I Div. 2, Article 502 Class II
Div. 1 & 2, Article 503 Class III Div. 1 & 2.
• Manufactured in a full range of trade sizes from 3/8" through 4".
• Approved for direct burial and in concrete trade sizes
3/8" through 4".
• Complies with UL Standard 360 File No. E18917; CSA
C22.2 File No. 158897; and NEC Article 350.
Square-Locked Design with integral bonding wire 3/8" through 1-1/4"
Interlocked Design 1-1/2" through 4" with no bonding wire
NEC Articles
• Article 250.118 (6) Equipment Grounding
• Article 300.22 (D) Information Technology Equipment
• Article 350 Liquid-Tight Flexible Metal Conduit (LFMC)
• Article 501.10 (B) (2) Class
I Div. 2
• Article 502.10 (A) (2) and (B) (2) Class
II Div. 1 & 2
• Article 503.10 (A) (3) and (B) Class
III Div. 1 & 2
• Article 620.21 Elevator Wiring Methods
• Article 645.5 (E) (2) Under Raised Floors www.ul.com www.nfpa.org www.nema.org www.csa-international.org www.naed.org www.anametelectrical.com
U.L. LISTED • CSA CERTIFIED • RoHS WEEE COMPLIANT
Gray or Black thermoplastic PVC jacket with integral bonding wire 3/8" through 1-1/4"
Product Specifications
Electrical
Trade Size
Inches mm
Inside Diameter Outside Diameter
Inches Inches
3/8
1/2
3/4
1
1-1/4
1-1/2
2
2-1/2
3
3-1/2
12
16
21
27
35
41
53
63
78
91
MIN.
MAX.
.484 – .504
.622 – .642
.820 – .840
1.041 – 1.066
1.380 – 1.410
1.575 – 1.600
2.020 – 2.045
2.480 – 2.505
3.070 – 3.100
3.500 – 3.540
4.000 – 4.040
MIN.
MAX.
.690 – .710
.822 – .840
1.030 – 1.050
1.290 – 1.315
1.630 – 1.660
1.865 – 1.900
2.340 – 2.375
2.840 – 2.875
3.460 – 3.500
3.960 – 4.000
4.460 – 4.500
4 103
Note: 1. Gray - Specification above.
2. Black - Change third number in NAED code to “0”.
3. Other Colors are available upon request.
3.0
3.5
5.0
6.0
7.0
5.5
7.0
9.5
15
16
17
Approx
Inside
Bend
Radius
Inches
Approx
Weight lbs.
PER
100 FT.
25
29
44
73
100
112
148
182
255
314
362
Small Carton
Length NAED
Feet
100
100
100
PIN
34202
34212
34222
Ordering Information
Standard Carton
Length NAED
Feet
200
200
150
100
50
50
50
25
25
25
25
PIN
34201
34211
34221
34231
34241
34251
34261
34272
34281
34301
34291
Small Reels
Length NAED
Feet
800
500
500
400
250
150
100
PIN
34204
34214
34228
34238
34248
34254
34268
Standard Reels
Length NAED
Feet
1500
1000
1000
PIN
34203
34213
34229
100
100
100
100
34274
34284
34304
34294
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type UA. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 3/8" thru 1-1/4". Conduit shall have a sunlight resistant and flame retardant PVC jacket in electrical trade sizes 3/8" thru 4". Conduit shall be UL listed, CSA certified and IP 66/67 rated when installed with approved end connectors.
6
CAT-UA-130901
ANAMET Electrical, Inc.
Anaconda SEALTITE ®
Flexible All Purpose
Liquid-Tight Flexible Metal Conduit (LFMC)
Construction
• Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance.
• Durable, sunlight resistant thermoplastic PVC jacket that resists heat, oil and chemical breakdown.
Square-Locked Design with cord packing 5/16” through 1-1/4”
Installation
• Conduit used with standard liquid-tight connector for easy installation. IP 66/67 Rated when installed with approved connectors.
• Delivers superior wiring protection where agency approvals are not required.
• Manufactured in a full range of sizes from 1/4" through
6". Conduit sizes 2-1/2", 3", 3-1/2" and 4" are Type
UA/EFST See page 7 for specifications.
• Smooth appearing cover for exposed applications.
• Rated for temperature range of -4˚F to +140˚F (-20˚C to +60˚C).
• Provides liquid-tight raceway for electrical conductors.
Interlocked Design
1/4” and 1-1/2” through 4”
• RoHS WEEE COMPLIANT www.nema.org www.naed.org www.anametelectrical.com
Gray or Black thermoplastic PVC jacket no bonding wire
Product Specifications
Electrical
Trade Size
Inches mm
Inside Diameter Outside Diameter
Inches Inches
MIN.
MAX.
MIN.
MAX.
1/4
5/16
3/8
1/2
3/4
1
1-1/4
1-1/2
7
10
12
16
21
27
35
41
.245 – .260
.390 – .405
.485 – .505
.620 – .640
.815 – .835
1.030 – 1.055
1.370 – 1.395
1.575 – 1.600
.445 – .460
.560 – .575
.690 – .710
.820 – .840
1.030 – 1.050
1.290 – 1.315
1.635 – 1.660
1.865 – 1.900
2
3
4
5
6
2-1/2
3-1/2
53
63
78
91
103
129
155
2.020 – 2.045
2.480 – 2.505
3.070 – 3.100
3.500 – 3.540
4.000 – 4.040
4.975 – 5.035
6.015 – 6.075
2.340
2.840
3.460
3.960
4.460
5.505
6.565
– 2.375
– 2.875
– 3.500
– 4.000
– 4.500
– 5.565
– 6.625
Note: 1. Gray – Specification above.
2. Black – Change third number in NAED code to “0”.
3. Other colors available upon request.
Approx
Inside
Bend
Radius
Inches
7.0
9.5
15
16
17
22
30
1.7
2.0
2.0
2.5
3.0
4.0
4.5
5.5
Ordering Information
Approx
Weight lbs.
PER
100 FT.
136
182
255
314
362
534
666
14
15
21
25
39
51
66
104
Small Carton
Length
Feet
Standard Carton
NAED Length
PIN Feet
NAED
PIN
100
100
100
500
500
250
200
36181
36191
36201
36211
36202
36212
36222
100
50
50
50
25
25
25
25
25
25
36231
36241
36251
36261
34272
34281
34301
34291
36351
36361
Small Reels
Length
Feet
NAED
PIN
800
500
500
400
250
150
100
Standard Reels
Length
Feet
NAED
PIN
36204 1500
36214 1000
36228 1000
36238
36248
36254
36268
100
100
100
100
36203
36213
36226
34274
34284
34304
34294
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type EFST. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant PVC outer jacket. Type EFST conduit shall be used for applications where agency approvals are not required. Conduit IP 66/67 rated when installed with approved end connectors.
ANAMET Electrical, Inc. CAT-EFST-130901 7
Anaconda SEALTITE ®
General Construction Grade
Liquid-Tight Flexible Metal Conduit (LFMC)
Construction
• Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance.
• Durable, sunlight resistant thermoplastic PVC jacket that resists heat, oil and chemical breakdown.
Installation
• Conduit used with standard liquid-tight connector for easy installation. IP 66/67 Rated when installed with approved connectors.
• Delivers superior wiring protection where agency approvals are not required.
• Manufactured in a full range of trade sizes from 3/8" through 2".
• Smooth appearing jacket for exposed applications.
• Rated for temperature range of -4˚F to +140˚F
(-
20˚C to +60˚C).
• Provides liquid-tight raceway for electrical conductors.
Square-Locked Design 3/8" through 2" www.naed.org www.nema.org www.anametelectrical.com
• RoHS WEEE COMPLIANT
Gray thermoplastic PVC jacket no bonding wire
Product Specifications
Electrical
Trade Size
Inches mm
3/8
1/2
3/4
1
1-1/4
12
16
21
27
35
Inside Diameter Outside Diameter
Inches Inches
MIN.
MAX.
.485 – .505
.620 – .640
.815 – .835
1.030 – 1.055
1.370 – 1.395
1.575 – 1.600
MIN.
MAX.
.690 – .710
.820 – .840
1.030 – 1.050
1.290 – 1.315
1.635 – 1.660
1.865 – 1.900
Approx
Inside
Bend
Radius
Inches
2.0
2.5
3.0
4.0
4.5
5.5
Approx
Weight lbs.
PER
100 FT.
17
19
26
45
65
1-1/2 41 95
2 53 2.020 – 2.045
2.340 – 2.375
7.0
120
NOTE: 1. Other colors available upon request.
2. Standard SEALTITE® Type EFST is recommended in sizes above 2”
Ordering Information
Small Carton
Length
Standard Carton
NAED Length NAED
Feet PIN Feet PIN
100
100
39402
39412
250
200
39401
39411
100
100
50
50
50
39422
39431
39441
39451
39461
Small Reels
Length NAED
Feet PIN
800
500
500
400
250
150
100
Standard Reels
Length NAED
Feet PIN
39404
39414 1000
39428 1000
39438
39448
39454
39468
39413
39429
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type EF. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant PVC outer jacket. Type EF conduit shall be used for applications where agency approvals are not required. Conduit IP 66/67 rated when installed with approved end connectors.
8 CAT-EF-130901
ANAMET Electrical, Inc.
Anaconda SEALTITE ®
UL Listed, CSA Certified
Higher and Lower Temperatures
Liquid-Tight Flexible Metal Conduit (LFMC)
Construction
• Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance.
• Durable, sunlight resistant and flame retardant thermoplastic PVC jacket that resists heat, oil and chemical breakdown.
• Designed for most extreme temperature applications.
Installation
• Conduit used with standard liquid-tight connector for easy installation. IP 66/67 Rated when installed with approved connectors.
• Approved for both exposed and concealed locations
Rated for temperature ranges UL temps -51°F to +
221°F (-46°C to +105°C), CSA -51°F to 167°F (-46°C to +75°C).
• Approved as an equipment grounding conductor in sizes 3/8" through 1-1/4" if the total grounding path is
6 ft. or less and the circuit conductors are protected by over 20 amps for 3/8" and 1/2" and 60 amps or less for
3/4" through 1-1/4".
• Suitable for use in hazardous locations per NEC
Articles 501 Class I Div. 2, Article 502 Class II Div. 1 &
2, Article 503 Class III Div. 1 & 2.
• Manufactured in a full range of trade sizes from 3/8" through 4".
• Approved for direct burial and in concrete trade sizes
3/8" through 4".
• Complies with UL Standard 360 File No. E18917; CSA
C22.2 File No. 158897; and NEC Article 350.
U.L. LISTED • CSA CERTIFIED
Square-Locked Design with integral bonding wire 3/8” through 1-1/4”
Interlocked Design 1-
1/2” through 4” with no bonding wire
NEC Articles
• Article 250.118 (6) Equipment Grounding
• Article 300.22 (D) Information Technology Equipment
• Article 350 Liquid-Tight Flexible Metal Conduit (LFMC)
• Article 501.10 (B) (2) Class
I Div. 2
• Article 502.10 (A) (2) and (B) (2) Class
II Div. 1 & 2
• Article 503.10 (A) (3) and (B) Class
III Div. 1 & 2
• Article 620.21 Elevator Wiring Methods
• Article 645.5 (E) (2) Under Raised Floors www.ul.com www.nfpa.org www.nema.org www.csa-international.org www.naed.org www.anametelectrical.com
• RoHS WEEE COMPLIANT
Gray or Black thermoplastic PVC jacket with integral bonding wire 3/8" through 1-1/4"
Product Specifications
Electrical
Trade Size
Inches mm
Inside Diameter Outside Diameter
Inches Inches
Approx
Inside
Bend
Radius
Inches
Ordering Information
Approx
Weight lbs.
PER
Small Cartons
Length NAED
3/8
1/2
3/4
1
1-1/4
12
16
21
27
35
MIN.
MAX.
.484 – .504
.622 – .642
.820 – .840
1.041 – 1.066
1.380 – 1.410
1.575 – 1.600
MIN.
MAX.
.690 – .710
.822 – .840
1.030 – 1.050
1.290 – 1.315
1.630 – 1.660
1.865 – 1.900
3.0
3.5
5.0
6.0
7.0
100 FT.
24
29
43
73
100
Feet
100
100
100
100
50
PIN
37402
37412
37422
37431
37441
1-1/2 41 5.5
112 50 37451
2 53 2.020 – 2.045
2.340 – 2.375
7.0
148 50 37461
2-1/2
3
3-1/2
4
63
78
91
103
2.480 – 2.505
3.070 – 3.100
3.500 – 3.540
4.000 – 4.040
2.840 – 2.875
3.460 – 3.500
3.960 – 4.000
4.460 – 4.500
9.5
15
16
17
181
255
305
361
50
25
25
25
37471
37481
37301
37491
NOTE: 1. Gray – Specification above.
2. Black – Change third number in NAED code to “6”. Available in small cartons and small reels only.
3. Other colors available upon request.
Small Reels
Length NAED
Feet
800
500
500
400
250
150
100
PIN
37404
37414
37428
37438
37448
37454
37468
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type HTUA. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 3/8" thru
1-1/4". Conduit shall have a sunlight resistant and flame retardant PVC jacket in electrical trade sizes 3/8" thru 4". Conduit shall be UL listed, CSA certified and IP 66/67 rated when installed with approved end connectors.
ANAMET Electrical, Inc.
CAT-HTUA-130901 9
Anaconda SEALTITE ®
Construction
• Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance.
• Durable, sunlight resistant thermoplastic PVC jacket that resists heat, oil and chemical breakdown.
Temperature Conditions
Are Higher/Lower Than Normal
Liquid-Tight Flexible Metal Conduit (LFMC)
Square-Locked Design with cord packing 3/8" through 1-1/4"
Installation
• Conduit used with standard liquid-tight connector for easy installation. IP 66/67 Rated when installed with approved connectors.
• Delivers superior wiring protection where agency approvals are not required.
• Manufactured in a full range of trade sizes from 3/8" through 4".
• Smooth appearing jacket for exposed applications.
• Rated for temperature range of -51˚F to +221˚F (-46˚C to +105˚C).
• Provides liquid-tight raceway for electrical conductors.
Interlocked Design 1-1/2" through 4" www.naed.org www.nema.org www.anametelectrical.com
• RoHS WEEE COMPLIANT
Gray or Black thermoplastic
PVC jacket no bonding wire
Product Specifications Ordering Information
3/8
1/2
Electrical
Trade Size
Inches
3/4 mm
12
16
21
Inside Diameter Outside Diameter
Inches
MIN.
MAX.
MIN.
Inches
MAX.
.485 – .505
.620 – .640
.815 – .835
.690
.820
1.030
– .710
– .840
– 1.050
Approx
Inside
Bend
Radius
Inches
2.0
2.5
3.0
Approx
Weight lbs.
PER
100 FT.
21
25
39
Small Carton
Length
Feet
100
100
100
NAED
PIN
37202
37212
37222
1
1-1/4
1-1/2
27
35
41
1.030 – 1.055
1.370 – 1.395
1.575 – 1.600
2.020 – 2.045
1.290 – 1.315
1.635 – 1.660
1.865 – 1.900
2.340 – 2.375
4.0
4.5
5.5
51
66
104
100
50
50
37231
37241
37251
2 53 7.0
136 50 37261
NOTE: 1. Gray - specification above.
2. Black Change third number in NAED code to “0”. Available in small cartons and small reels only.
3. Sizes above 2" available on special order.
4. Other colors available upon request.
Small Reels
Length
Feet
NAED
PIN
800
500
500
400
250
150
100
37204
37214
37228
37238
37248
37254
37268
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type HC. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant PVC outer jacket. Type
HC conduit shall be used for applications where agency approvals are not required. Conduit IP 66/67 rated when installed with approved end connectors.
10 CAT-HC-130901
ANAMET Electrical, Inc.
Anaconda SEALTITE ®
Construction
• Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance.
• Durable, sunlight resistant thermoplastic rubber jacket that resists heat, oil and chemical breakdown.
Extreme Temperature Jacket
Liquid-Tight Flexible Metal Conduit (LFMC)
Square-Locked Design with cord packing 3/8” through 1-1/4”
Installation
• Conduit used with standard liquid-tight connector for easy installation. IP 66/67 Rated when installed with approved connectors.
• Delivers superior wiring protection where agency approvals are not required.
• Manufactured in a full range of trade sizes from 3/8" through 4".
• Smooth appearing jacket for exposed applications.
• Rated for temperature range of -76˚F to +302˚F (-60˚C to +150˚C).
• Provides liquid-tight raceway for electrical conductors.
Interlocked Design 1-
1/2” through 4” www.naed.org www.nema.org www.anametelectrical.com
• RoHS WEEE COMPLIANT
Black thermoplastic rubber jacket no bonding wire
Product Specifications
3/8
1/2
3/4
Electrical
Trade Size
Inches mm
12
16
21
Inside Diameter Outside Diameter
Inches
MIN.
MAX.
MIN.
Inches
MAX.
.485 – .505
.620 – .640
.815 – .835
1.030 – 1.055
.690
.820
1.030
1.290
– .710
– .840
– 1.050
– 1.315
1 27
1-1/4
1-1/2
35
41
1.370 – 1.395
1.575 – 1.600
1.635
1.865
– 1.660
– 1.900
2 53 2.020 – 2.045
2.340 – 2.375
Note: Sizes above 2” available on special order
Approx
Inside
Bend
Radius
Inches
2.0
2.5
3.0
4.0
4.5
5.5
7.0
Approx
Weight lbs.
PER
100 FT.
21
25
39
51
66
104
136
Ordering Information
Standard Carton
Length
Feet
NAED
PIN
100
100
39102
39112
100
100
39122
39131
50
50
50
39141
39151
39161
Small Reels
Length
Feet
NAED
PIN
800
500
39104
39114
500
400
39128
39138
250
150
100
39148
39154
39168
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type HCX. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant rubber outer jacket. Type
HCX conduit shall be used for applications where agency approvals are not required. Conduit IP 66/67 rated when installed with approved end connectors.
ANAMET Electrical, Inc.
CAT-HCX-130901 11
Anaconda SEALTITE ®
Zero Halogen-Low Smoke-Low Flame Spread*
UL Listed Liquid-Tight Flexible Metal Conduit (LFMC)
Construction
• Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance.
• Durable, sunlight resistant, flame retardant, LOW
SMOKE and ZERO HALOGEN TPU jacket that resists heat, oil and chemical breakdown.
• Designed for most extreme temperature applications.
• Meets the demands of today’s higher temperature rated conductors.
Square-Locked Design with integral bonding wire 3/8” through 1-1/4”
Installation
• Conduit used with standard liquid-tight connector for easy installation. IP 66/67 Rated when installed with approved connectors.
• Approved for both exposed and concealed locations.
Rated for temperature ranges -40°F to + 176°F (-40°C to +80°C).
• Approved as an equipment grounding conductor in sizes 3/8" through 1-1/4" if the total grounding path is
6 ft. or less and the circuit conductors are protected by over 20 amps for 3/8" and 1/2" and 60 amps or less for
3/4" through 1-1/4".
• Suitable for use in hazardous locations per NEC Article
501 Class I Div. 2, Article 502 Class II Div. 1 & 2, Article
503 Class III Div. 1 & 2.
• Manufactured in a full range of sizes from 3/8" through 4".
• Approved for direct burial and in concrete trade sizes
3/8" through 4".
• All Sizes Comply with UL Standard 360 File No.
E18917; and Trade sizes 1/2” and 3/4” are CUL Listed.
U.L. LISTED
Interlocked Design 1-
1/2” through 4” with no bonding wire
MEETS or EXCEEDS the following STANDARDS
• Flame Spread Index ASTM E162
• Smoke Density (Generation) ASTM E662
• Toxic Gas Generation Bombardier BSS 7239
• Jacket Material is U.L. 94 Certified
• Conduit is U.L. 360 Listed
NEC Articles
• Article 250.118 (6) Equipment Grounding
• Article 300.22 (D) Information Technology Equipment
• Article 350 Liquid-Tight Flexible Metal Conduit (LFMC)
• Article 501.10 (B) (2) Class
I Div. 2
• Article 502.10 (A) (2) and (B) (2) Class
II Div. 1 & 2
• Article 503.10 (A) (3) and (B) Class
III Div. 1 & 2
• Article 620.21 Elevator Wiring Methods
• Article 645.5 (E) (2) Under Raised Floors www.ul.com www.naed.org www.nfpa.org www.nema.org www.anametelectrical.com
• RoHS WEEE COMPLIANT
Black Zero Halogen jacket with integral bonding wire 3/8" through 1-1/4"
Product Specifications Ordering Information
Electrical
Trade Size Inside Diameter Outside Diameter
Inside
Bend
Radius
Inches
Approx
Weight lbs.
PER
Standard Carton Small Reels
Inches mm Inches Inches Length NAED Length
3/8
1/2
3/4
1
1-1/4
1-1/2
12
16
21
27
35
41
MIN.
MAX.
.484 – .504
.622 – .642
.820 – .840
1.041 – 1.066
1.380 – 1.410
1.575 – 1.600
2.020 – 2.045
MIN.
MAX.
.690 – .710
.822 – .840
1.030 – 1.050
1.290 – 1.315
1.630 – 1.660
1.865 – 1.900
2.340 – 2.375
3.0
3.5
5.0
6.0
7.0
5.5
100 FT.
25
29
44
73
100
112
Feet
100
100
100
100
50
50
PIN
39802
39812
39822
39831
39841
39851
Feet
500
500
500
400
200
150
2 53 7.0
148 50 39861 100
2-1/2
3
3-1/2
4
63
78
91
103
2.480 – 2.505
3.070 – 3.100
3.500 – 3.540
4.000 – 4.040
2.840 – 2.875
3.460 – 3.500
3.960 – 4.000
4.460 – 4.500
9.5
15
16
17
182
255
314
362
25
25
25
25
39872
39881
39791
39891
NOTE: 1. Black – Specification above. 2. Colors are available upon request. 3. Trade sizes 1/2” and 3/4” CUL Listed
* Test data results obtained from an independent test laboratory. Consult factory for additional details.
NAED
PIN
39808
39814
39828
39838
39844
39854
39868
Standard Reels
Length
Feet
1000
1000
1000
NAED
PIN
39809
39813
39829
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type ZHUA. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 3/8” thru 1-1/4”. Conduit shall have a sunlight resistant, flame retardant, LOW SMOKE AND ZERO HALOGEN TPU jacket in el ectrical trade sizes 3/8” thru 4”. Conduit shall be UL listed, and IP
66/67 rated when installed with approved end connectors.
ANAMET Electrical, Inc.
CAT-ZHUA-130901 13
Anaconda SEALTITE ®
UL Listed, CSA Certified,
Computer Blue
Liquid-Tight Flexible Metal Conduit (LFMC)
Construction
• Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance.
• Durable, sunlight resistant and flame retardant thermoplastic PVC jacket that resists heat, oil and chemical breakdown.
Installation
• Conduit used with standard liquid-tight connector for easy installation. IP 66/67 Rated when installed with approved connectors.
• Approved for both exposed and concealed locations.
Rated for temperature ranges -4°F to + 140°F (-20°C to
+60°C).
• Approved as an equipment grounding conductor in sizes 1/2" through 1-1/4, if the total grounding path is
6 ft. or less and the circuit conductors are protected by over 20 amps for 1/2" and 60 amps or less for 3/4" through 1-1/4".
• Suitable for use in hazardous locations per NEC
Articles 501 Class I Div. 2, Article 502 Class II Div. 1 &
2, Article 503 Class III Div. 1 & 2.
• Manufactured in a full range of trade sizes from 1/2" through 3".
• Approved for direct burial and in concrete trade sizes
1/2" through 3".
• Complies with UL Standard 360 File No. E18917; CSA
C22.2 File No. 158897; and NEC Article 350.
Square-Locked Design with integral bonding wire 1/2" through 1-1/4"
Interlocked Design 1-1/2" through 3" with no bonding wire
NEC Articles
• Article 250.118 (6) Equipment Grounding
• Article 300.22 (D) Information Technology Equipment
• Article 350 Liquid-Tight Flexible Metal Conduit (LFMC)
• Article 501.10 (B) (2) Class
I Div. 2
• Article 502.10 (A) (2) and (B) (2) Class
II Div. 1 & 2
• Article 503.10 (A) (3) and (B) Class
III Div. 1 & 2
• Article 620.21 Elevator Wiring Methods
• Article 645.5 (E) (2) Under Raised Floors www.ul.com www.nfpa.org www.nema.org www.csa-international.org www.naed.org www.anametelectrical.com
U.L. LISTED • CSA CERTIFIED • RoHS WEEE COMPLIANT
Blue thermoplastic PVC jacket with integral bonding wire 1/2" through 1-1/4"
Product Specifications
Electrical
Trade Size
Inches mm
Inside Diameter Outside Diameter
Inches Inches
1/2
3/4
1
1-1/4
1-1/2
2
2-1/2
16
21
27
35
41
53
63
MIN.
MAX.
.622 – .642
.820 – .840
1.041 – 1.066
1.380 – 1.410
1.575 – 1.600
2.020 – 2.045
2.480 – 2.505
3.070 – 3.100
MIN.
MAX.
.822 – .840
1.030 – 1.050
1.290 – 1.315
1.630 – 1.660
1.865 – 1.900
2.340 – 2.375
2.840 – 2.875
3.460 – 3.500
3 78
NOTE: 1. Other colors available upon request.
2. 3/8" & 4" trade sizes available on special order.
Approx
Inside
Bend
Radius
Inches
3.5
5.0
6.0
7.0
5.5
7.0
9.5
15
Approx
Weight lbs.
PER
100 FT.
29
44
73
100
112
148
182
255
Ordering Information
Standard Carton
Length
Feet
NAED
PIN
100
100
100
50
50
50
50
25
34512
34522
34531
34541
34551
34561
34571
34581
Small Reels
Length
Feet
NAED
PIN
500
500
400
250
150
34514
34528
34538
34548
34554
Standard Reels
Length
Feet
NAED
PIN
1000 34513
1000 34526
600 34533
100
100
34568
34574
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type CW. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 1/2” thru 1-1/4”. Conduit shall have a sunlight resistant and flame retardant PVC jacket in electrical trade sizes 1/2” thru 3”. Conduit shall be UL listed, CSA certified and IP 66/67 rated when installed with approved end connectors.
14 CAT-CW-130901
ANAMET Electrical, Inc.
Anaconda SEALTITE ®
Construction
• Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance.
• Durable, sunlight resistant thermoplastic PVC jacket that resists heat, oil and chemical breakdown.
Special Oil Resistant Jacket
Liquid-Tight Flexible Metal Conduit (LFMC)
Square-Locked Design with cord packing 3/8” through 1-1/4”
Installation
• Conduit used with standard liquid-tight connector for easy installation. IP 66/67 Rated when installed with approved connectors.
• Delivers superior wiring protection where agency approvals are not required.
• Manufactured in a full range of trade sizes from 3/8" through 4".
• Smooth appearing jacket for exposed applications.
• Rated for temperature range of -9˚F to +221˚F (-23˚C to
+105˚C).
• Provides liquid-tight raceway for electrical conductors.
Interlocked Design 1-
1/2” through 4” www.naed.org www.nema.org www.anametelectrical.com
• RoHS WEEE COMPLIANT
Black or Gray thermoplastic PVC jacket no bonding wire
Product Specifications Ordering Information
Electrical
Trade Size
Inches mm
Inside Diameter Outside Diameter
Inches Inches
Approx
Inside
Bend
Radius
Inches
Approx
Weight lbs.
PER
Small Carton
Length NAED
3/8
1/2
3/4
1
1-1/4
12
16
21
27
35
MIN.
MAX.
.485 – .505
.620 – .640
.815 – .835
1.030 – 1.055
1.370 – 1.395
1.575 – 1.600
MIN.
MAX.
.690 – .710
.820 – .840
1.030 – 1.050
1.290 – 1.315
1.635 – 1.660
1.865 – 1.900
2.0
2.5
3.0
4.0
4.5
100 FT.
21
25
39
51
66
Feet
100
100
100
100
50
PIN
36602
36612
36622
36631
36641
1-1/2 41 5.5
104 50 36651
2 53 2.020 – 2.045
2.340 – 2.375
7.0
136 50 36661
NOTE: 1. Black – specification above.
2. Gray – Change third number in NAED code to “8”. Available in small cartons and small reels only.
3. Sizes above 2” available on special order.
Small Reels
Length NAED
Feet PIN
800
500
500
400
250
150
100
36604
36614
36628
36638
36648
36654
36668
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type OR. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant PVC outer jacket. Type
OR conduit shall be used for applications where agency approvals are not required. Conduit IP 66/67 rated when installed with approved end connectors.
ANAMET Electrical, Inc.
CAT-OR-130901 15
Anaconda SEALTITE ®
Aluminum Core Light Weight
Liquid-Tight Flexible Metal Conduit (LFMC)
Construction
• Constructed of continuously interlocked aluminum core for exceptional crush and corrosion resistance.
• Durable, sunlight resistant thermoplastic PVC jacket that resists heat, oil and chemical breakdown.
Square-Locked Design with cord packing 3/8" through 1-1/4"
Installation
• Conduit used with standard liquid-tight connector for easy installation. IP 66/67 Rated when installed with approved connectors.
• Delivers superior wiring protection where agency approvals are not required.
• Manufactured in a full range of trade sizes from 3/8" through 4".
• Smooth appearing jacket for exposed applications.
• Rated for temperature range of -4˚F to +140˚F (-20˚C to
+60˚C).
• Provides liquid-tight raceway for electrical conductors.
Interlocked Design 1-1/2" through 4" www.naed.org www.nema.org www.anametelectrical.com
• RoHS WEEE COMPLIANT
Gray thermoplastic PVC jacket no bonding wire
Product Specifications
Electrical
Trade Size
Inches
3/8
1/2 mm
12
16
Inside Diameter Outside Diameter
Inches Inches
MIN.
MAX.
.485 – .505
.620 – .640
MIN.
MAX.
.690 – .710
.820 – .840
3/4
1
1-1/4
1-1/2
21
27
35
41
.815 – .835
1.030 – 1.055
1.370 – 1.395
1.575 – 1.600
1.030 – 1.050
1.290 – 1.315
1.635 – 1.660
1.865 – 1.900
2
2-1/2
3
4
53
63
78
103
2.020 – 2.045
2.480 – 2.505
3.070 – 3.100
4.000 – 4.040
NOTE: 1. Other colors available upon request.
2.340 – 2.375
2.840 – 2.875
3.460 – 3.500
4.460 – 4.500
2.0
2.5
3.0
4.0
4.5
5.5
7.0
9.5
15
17
Approx
Inside
Bend
Radius
Inches
Ordering Information
Approx
Weight lbs.
PER
Standard Carton
Length NAED
100 FT.
Feet PIN
14
16
100
100
38002
38012
19
32
42
58
78
103
123
196
100
100
50
50
50
50
25
25
38022
38031
38041
38051
38061
38071
38081
38091
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type EFL. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked aluminum core with sunlight resistant PVC outer jacket. Type EFL conduit shall be used for applications where agency approvals are not required. Conduit
IP 66/67 rated when installed with approved end connectors.
16 CAT-EFL-130901
ANAMET Electrical, Inc.
Anaconda SEALTITE ®
Construction
• Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance.
• Durable, sunlight resistant thermoplastic PVC jacket that resists heat, oil and chemical breakdown.
Installation
• Conduit used with standard liquid-tight connector for easy installation. IP 66/67 Rated when installed with approved connectors.
• Delivers superior wiring protection where agency approvals are not required.
• Manufactured in a full range of trade sizes from 3/8" through 2".
• Smooth appearing jacket for exposed applications.
• Rated for temperature range of -4˚F to +140˚F (-20˚C to +60˚C).
• Provides liquid-tight raceway for electrical conductors.
Machine Tool Conduit
Liquid-Tight Flexible Metal Conduit (LFMC)
Square-Locked Design 3/8" through 2" www.naed.org www.nema.org www.anametelectrical.com
• RoHS WEEE COMPLIANT
Black thermoplastic PVC jacket
Product Specifications Ordering Information
Electrical
Trade Size
Inches mm
3/8
1/2
3/4
1
1-1/4
1-1/2
2
12
16
21
27
35
41
53
Inside Diameter Outside Diameter
Inches
MIN.
MAX.
MIN.
Inches
MAX.
.485 – .505
.620 – .640
.815 – .835
.679
.818
1.009
– .704
– .843
– 1.034
1.030 – 1.055
1.370 – 1.395
1.570 – 1.595
2.010 – 2.035
1.228 – 1.258
1.565 – 1.595
1.830 – 1.860
2.270 – 2.300
Approx
Inside
Bend
Radius
Inches
1.5
2.0
2.5
3.0
3.5
4.0
5.0
Approx
Weight lbs.
PER
100 FT.
16
20
24
30
40
70
87
Standard Carton
Length
Feet
NAED
PIN
100
100
100
38302
38312
38322
100
50
50
50
38331
38341
38351
38361
Small Reels
Length
Feet
NAED
PIN
800
500
500
38304
38314
38328
400
250
150
100
38338
38348
38354
38368
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type MTC. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with sunlight resistant PVC outer jacket. Type
MTC conduit shall be used for applications where agency approvals are not required. Conduit IP 66/67 rated when installed with approved end connectors.
ANAMET Electrical, Inc.
CAT-MTC-130901 17
Anaconda SEALTITE ®
Stainless Steel Liquid-Tight
Flexible Metal Conduiit
(LFMC) Connectors
Construction
• Stainless Steel Type 304 connector, has a four piece construction consisting of a gland nut, sealing ring, high tensile grounding cone and body.
• Designed with an insulated throat to prevent wire damage during installation.
• Included sealing ring and stainless steel lock nut provides a means for connecting the fitting to boxes.
• Excellent corrosion resistance, strength and durability.
Installation
• Connector is ideal for use with standard liquid-tight conduit to allow easy installation. IP 66/67 Rated when installed with approved conduit.
• Approved for both exposed and concealed locations.
Rated for temperature ranges -49ºF to + 221ºF (-45ºC to +105ºC).
• Suitable for harsh industrial, food and beverage, petrochemical, waste water, salt water and other corrosive applications
• Suitable for use in hazardous locations per NEC
Articles 501 Class I Div. 2, Article 502 Class II
Div. 1 & 2, Article 503 Class III Div. 1 & 2.
• Manufactured in a range of trade sizes from 3/8" through 1".
• Complies with UL Standard 514B and
CSA C22.2 combined File No. E234207
Straight Connector NPT thread 3/8" through 1"
90° Connector NPT Thread 3/8" through 1"
NEC Articles
• Article 501.10 (B) (2) Class
I Div. 2
• Article 502.10 (A) (2) and (B) (2) Class
II Div. 1 & 2
• Article 503.10 (A) (3) and (B) Class
III Div. 1 & 2 www.ul.com www.nfpa.org www.nema.org www.csa-international.org www.naed.org www.anametelectrical.com
U.L. LISTED
Type 304
• CSA CERTIFIED • RoHS WEEE COMPLIANT
Product Specifications
Electrical
Trade Size
Inches mm
K.O. Size
Inches
3/8
3/8
1/2
1/2
3/4
3/4
1
1
12
12
16
16
21
21
27
27
1/2
1/2
1/2
1/2
3/4
3/4
1
1
A
1.457
1.457
1.457
1.457
1.575
1.693
1.811
1.890
Note: 1. Other sizes available on special order
B
0.512
0.512
0.512
0.512
0.591
0.591
0.591
0.591
Dimensions
Inches
C
1.024
1.024
1.142
1.142
1.379
1.379
1.772
1.772
D
1.693
1.693
1.890
2.323
Approx
Weight lbs.
PER
Pkg.
3.5
2.2
4.4
2.8
2.4
3.5
1.5
2.6
Ordering Information
Straight Connectors
Standard AEI
90° Connectors
Standard AEI
Package
25
25
10
5
PIN
81401292
81401692
81402092
81402692
Package
10
10
10
5
PIN
81491292
81491692
81492092
81492692
18 CAT-SSLTC-130901
ANAMET Electrical, Inc.
Anaconda SEALTITE ®
Construction
• Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance.
• Extra Flexible steel construction.
• Recognized Component, for use by OEM’s as part of manufactured wiring systems.
Installation
• Used in office furnishings, work stations and partitions.
• Exceptional flexibility for tight “U” bend radius.
• Complies with UL Recognized File No. E-39679;
DXUZ2.
• Size range, actual I.D. 5/16" through 3/4".
• Available in custom-cut lengths.
• +450˚F maximum temperature.
Heavy-Duty
UL Recognized Component Ver y flexible for OEM and Industrial Application
Square Locked Design
5/16” through 3/4”
NEC Articles
• Article 604 Manufactured Wiring Systems www.ul.com www.anametelectrical.com
• UL RECOGNIZED COMPONENT DXUZ2
Unjacketed flexible steel conduit
• RoHS WEEE COMPLIANT
Product Specifications
Approx
Nominal
Size Inches
Inches mm
Inside Diameter Outside Diameter
Inches Inches
Inside
Bend
Radius
Inches
5/16*
3/8
7/16
1/2
8
9
11
13
MIN.
MAX.
.312 – .337
.375 – .400
.437 – .462
.500 – .525
.562 – .587
MIN.
.456
MAX.
– .481
.519 – .544
.581 – .606
.644 – .669
.708 – .731
1.25
1.25
1.5
1.5
9/16 14 1.5
5/8 15 .594 – .619
.738 – .763
1.75
3/4 18 .696 – .726
.840 – .870
2.25
Note: 1. Longer length reels available on request – consult factory.
* 5/16” size not UL recognized.
Ordering Information
Approx
Weight Part
Length Number lbs.
PER
100 FT.
11 Random
NAED
PIN
452100
12
13
15
16
Length
Coils
452105
452110
452115
452120
17
20
452125
452130
TyPICAL SPECIFICATION:
Heavy-Duty conduit very flexible for OEM and Industrial applications. Conduit shall be Anaconda Type
DE-710. Conduit shall be constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance. Conduit shall be UL recognized as a part of a manufactured wiring system.
ANAMET Electrical, Inc.
CAT-DE-710-130901 19
Anaconda SEALTITE ®
Construction
• Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance.
• Extra Flexible continuously interlocked steel construction.
Installation
• Installs easily with standard armored cable or flexible conduit connectors.
• Exceptional flexibility for tight “U” bend radius.
• Designed to be used for specific applications where agency approvals are not required.
• Special sizes available upon request.
• Available in custom-cut lengths.
• +450˚F maximum temperature.
All Purpose, Extra Flexible Uncovered Conduit
Light Duty/General Electrical Application
Square Locked Design
5/16” through 3/4” www.anametelectrical.com
Unjacketed flexible steel conduit
• RoHS WEEE COMPLIANT
Nominal
Size Inches
Inches mm
Product Specifications
Description
Number
Inside
Diameter
Inches
Outside
Diameter
Inches
Approx
Inside
Bend
Radius
Inches
Ordering Information
Standard Approx
Length Weight Part
Coil lbs.
Number
PER PER NAED
3/16
1/4
5/16
3/8
7/16
1/2
9/16
5/8
3/4
5
6
8
9
11
13
14
16
19
DSL3
DSL4
DSL5
DSL6
DSL7
DSL8
DSL9
DSL10
DSL12
MIN.
MAX.
.183 - .195
.245 - .260
.307 - .322
.368 - .388
.430 - .450
.493 - .513
.555 - .575
.618 - .638
.740 - .770
MIN.
MAX.
.263 - .275
.335 - .350
.417 - .432
.478 - .498
.545 - .565
.613 - .633
.680 - .700
.743 - .763
.865 - .895
1
1
1.25
1.5
1.5
1.5
1.5
2
2
100 FT.
250
250
250
200
200
200
200
150
150
100 FT.
4.4
5.8
6.6
8.8
10.0
11.6
13.2
19.1
22.9
PIN
460012
460022
460032
460042
460052
460057
460067
460072
460077
TyPICAL SPECIFICATION:
Conduit shall be Anaconda Type DSL. Conduit shall be constructed of continuously interlocked hot dipped zinc galvanized steel and provide a race-way for wiring. Conduit shall be considered all-purpose and be used for general purpose wiring where agency approvals are not required.
20 CAT-DSL-130901
ANAMET Electrical, Inc.
Anaconda SEALTITE ®
Construction
• Constructed of continuously interlocked, zinc-coated steel strip.
• Flexible with high crush resistance.
• Smooth exterior and interior allow for easy pulling and wire fishing.
Installation
• Uses standard flexible metal conduit connectors.
• Continuous grounding contact.
• UL Listed Standard #1, File # E98045.
• Manufactured in size range from 3/8" through 4".
• Complies with Article 348, NEC.
• Permitted to be used in exposed and concealed locations (Article 348.10); enclosed motor leads (Article
430.245(B); elevators, escalators, wheelchair lifts
(Article 620.21).
• +450˚F Maximum temperature.
Flexible Steel Conduit
UL Listed Flexible Metal Conduit (FMC)
Angle-Lock Design 3/8" through 4"
NEC Articles
• Article 250.102, 250.118(5) and 250.134(B) Equipment
Grounding.
• Article 300.22 (D) Information Technology Equipment
• Article 348 Flexible Metal Conduit. (FMC)
• Article 501.30 (B) Class
I Div. 2.
• Article 620.21 Elevator Wiring Methods
• Article 645.5 (E) (2) Under Raised Floors www.ul.com www.nema.org www.naed.org www.anametelectrical.com
• UL LISTED • RoHS WEEE COMPLIANT
Flexible steel conduit
Product Specifications Ordering Information
Electrical
Trade Size
Inches mm
3/8
1/2
12
16
Inside
Diameter
Inches
MIN.
MAX.
.375 – .393
.625 – .645
.812 – .835
Outside
Diameter
Inches
MIN.
MAX.
.560 – .610
.860 – .920
1.045 – 1.105
Approx
Inside
Bend
Radius
Inches
2
3
Approx
Weight lbs.
PER
100 FT.
18
28
Standard Coils
Length NAED
Feet
100
PIN
455503
100 455513
Standard Reels
Length NAED
Feet
1000
PIN
455507
1000 455517
3/4 21 4 33 100 455523 500 455526
1
1-1/4
1-1/2
27
35
41
1.000 – 1.040
1.250 – 1.300
1.500 – 1.575
2.000 – 2.080
1.300 – 1.380
1.550 – 1.630
1.850 – 1.950
2.350 – 2.450
5
6-1/4
7-1/2
51
63
76
50
50
25
455532
455542
455551
300
200
150
455533
455543
455553
2 53 10 100 25 455561 100 455563
2-1/2
3
3-1/2
4
63
78
91
103
2.500 –
3.000 –
3.500 –
4.000 –
2.860 – 3.060
3.360 – 3.560
3.860 – 4.060
4.360 – 4.560
12-1/2
15
17-1/2
20
165
197
230
263
25
25
25
25
455571
455581
455601
455591
TyPICAL SPECIFICATION:
Conduit shall be Anaconda Type RWS. Conduit shall provide flexible raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel. Conduit shall be UL listed in electrical trade sizes 3/8” thru 4”.
ANAMET Electrical, Inc.
CAT-RWS-130901 21
Anaconda SEALTITE ®
Construction
• Constructed of continuously interlocked aluminum strip.
Reduced Wall Flexible Aluminum
UL Listed Flexible Metal Conduit (FMC)
• Flexible with high crush resistance.
• Superior corrosion resistance.
• Smooth exterior and interior allow easy pulling and wire fishing.
Installation
• Uses standard flexible metal conduit connectors.
Angle-Lock Design 3/8" through 4"
NEC Articles
• Article 250.102, 250.118(5) and 250.134(B) Equipment
Grounding.
• Light weight, easy to cut.
• Article 300.22 (D) Information Technology Equipment • UL Listed Standard #1, File # E98045.
• Manufactured in size range from 3/8" through 4".
• Complies with Article 348, NEC.
• Article 348 Flexible Metal Conduit. (FMC)
• Article 501.30 (B) Class
I Div. 2.
• Permitted to be used in exposed and concealed locations (Article 348.10); enclosed motor leads (Article
430.245(B); elevators, escalators, wheelchair lifts
(Article 620.21).
• Article 620.21 Elevator Wiring Methods
• Article 645.5 (E) (2) Under Raised Floors www.ul.com www.naed.org
• +500˚F Maximum temperature.
www.nema.org www.anametelectrical.com
• UL LISTED • RoHS WEEE COMPLIANT
Flexible aluminum conduit
Product Specifications Ordering Information
Electrical
Trade Size
Inches mm
3/8
1/2
3/4
12
16
21
Inside Diameter Outside Diameter
Inches
MIN.
MAX.
MIN.
Inches
MAX.
.375 – .393
.625 – .645
.812 – .835
1.000 – 1.040
.560
.860
1.045
1.300
– .610
– .920
– 1.105
– 1.380
Approx
Inside
Bend
Radius
Inches
2
3
4
Approx
Weight lbs.
PER
100 FT.
6.5
9.5
12.5
Standard Coils
Length
Feet
NAED
PIN
100
100
100
441503
441513
441523
Standard Reels
Length
Feet
NAED
PIN
1000
1000
500
441507
441517
441526
1 27 5 18 50 441532 300 441533
1-1/4
1-1/2
2
2-1/2
3
3-1/2
4
35
41
53
63
78
91
103
1.250 – 1.300
1.500 – 1.575
2.000 – 2.080
2.500 –
3.000 –
3.500 –
4.000 –
1.550 – 1.630
1.850 – 1.950
2.350 – 2.450
2.860 – 3.060
3.360 – 3.560
3.860 – 4.060
4.360 – 4.560
6-1/4
7-1/2
10
12-1/2
15
17-1/2
20
22
26
35
57
68
80
91
50
25
25
25
25
25
25
441542
441551
441561
441571
441581
441601
441591
TyPICAL SPECIFICATION:
Conduit shall be Anaconda Type RWA flexible reduced wall aluminum conduit and be made of continuously interlocked aluminum strip.
Conduit shall be UL listed in electrical trade sizes 3/8” thru 4”.
22 CAT-RWA-130901
ANAMET Electrical, Inc.
Anaconda SEALTITE ®
High temperature Silicone coated fiberglass sleeve, tape, wrap and sheet.
FireT ech™ Sleeve
FireT ech™ Wrap
FireT ech™ Tape
FireT ech™ Sheet
FireT ech™ is the perfect insulator in steel mills, glass manufacturers and other places where conduit is exposed to fire, heat and molten splash. Built from high bulk fiberglass and coated with a thick covering of iron oxide red silicone rubber, FireT ech™ can take continuous exposure to temperatures of 500° F and shed molten slag as hot as
2,000° F for 15 minutes. Rugged and reliable, meets the requirements for criteria in the SAE Standard AS1055 Rev. D (Section 4.1.1 and
4.1.2) for hose assemblies utilizing a firesleeve material and it is excellent for use in zero halogen environments.
Inside Diameter
Inches
5/16
3/8
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
3 1/2
4
FireT ech™ Sleeve
PER
50 FT.
205161
200381
200121
200341
200101
201141
201121
200201
202121
200301
203121
200401
PER
100 FT.
205162
200382
200122
200342
200102
201142
201122
200202
202122
200302
203122
200402
Wrap, Tape
& Sheet
Width inches
1
1 1/2
2
3
4
5
36
60
FireT ech™ Wrap
PER
50 FT.
240011
240021
240031
240041
240051
PER
100 FT.
240012
240022
240032
240042
240052
FireT ech™
Tape
FireT ech™
Sheet
PER
36 FT.
231002
231126
Random Lengths up to 150 FT.
220036
220060
ANAMET Electrical, Inc.
CAT-FT-130901 23
Anaconda SEALTITE ®
UL Listed CSA Certified Nonconductive Conduit
Liquid-Tight Flexible Non-Metallic Conduit (LFNC)
Construction
• One-piece construction of rigid, non-metallic reinforcement embedded in flexible PVC wall for exceptional crush and corrosion resistance.
• Durable, sunlight resistant and flame retardant thermoplastic PVC that resists heat, oil and chemical breakdown.
Installation
• Conduit used with standard connectors for non-metallic conduit Type B for easy installation. IP 66/67 Rated when installed with approved connectors.
• Approved for both exposed and concealed locations.
Rated for temperature ranges of 17˚F to +176˚F (-27˚C to +80˚C).
• Complies with NEC Article 356 and UL Standard 1660
File No. E-211327; CSA C22.2 File No. 020817.
• Easy to install and cuts easily.
• Manufactured in a full range of trade sizes from 3/8" through 2".
• Approved for direct burial and in concrete trade sizes
3/8" through 2".
Rigid PVC Reinforced 3/8" through 2"
NEC Articles
• Article 250.102 Equipment Bonding Jumpers
• Article 250.134 (B) Equipment Grounding
• Article 300.22 (D) Information Technology Equipment
• Article 356 Liquid-Tight Flexible Nonmetallic Conduit
(LFNC-B)
• Article 501.10 (B) (2) Class
I Div. 2
• Article 502.10 (A) (2) and (B) (2) Class
II Div. 1 & 2
• Article 503.10 (A) (3) and (B) Class
III Div. 1 & 2
• Article 620.21 Elevator Wiring Methods
• Article 645.5 (E) (2) Under Raised Floors www.ul.com www.nfpa.org www.nema.org www.csa-international.org www.naed.org www.anametelectrical.com
U.L. LISTED
Gray thermoplastic PVC
• CSA CERTIFIED • RoHS WEEE COMPLIANT
Product Specifications Ordering Information
Electrical
Trade Size
Inches mm
Inside Diameter Outside Diameter
Inches Inches
Approx
Inside
Bend
Radius
Inches
Approx
Weight lbs.
PER
Standard Carton
Length NAED
Standard Reels
Length NAED
3/8
1/2
3/4
12
16
21
MIN.
MAX.
.484 – .504
.622 – .640
.820 – .840
1.041 – 1.066
MIN.
MAX.
.690 – .710
.820 – .840
1.030 – 1.050
1.290 – 1.315
2.0
3.5
4.5
100 FT.
13
14
16
Feet
100
100
100
PIN
39702
39712
39722
Feet
1000
1000
700
PIN
39708
39713
39724
1 27 6.5
26 100 39731 500 39734
1-1/4
1-1/2
2
35
41
53
1.380 – 1.410
1.575 – 1.600
2.020 – 2.045
1.635 – 1.660
1.865 – 1.900
2.340 – 2.375
8.0
9.0
11.0
34
45
62
50
50
50
39741
39753
39761
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type NMUA. Conduit shall be constructed of non-metallic PVC material and shall be used for inside, outside and corrosive applications in accordance with Article 356 of the National Electric Code. Conduit shall be used in applications requiring a temperature range of 17˚F to +176˚F (-27˚C to +80˚C) for dry locations. Conduit shall be UL listed and CSA certified as T ype “B” non-metallic conduit. Conduit IP 66/67 rated when installed with approved end connectors.
24 CAT-NMUA-130901
ANAMET Electrical, Inc.
Anaconda SEALTITE ®
Type B Liquid-Tight Flexible
Non-Metallic Conduit (LFNC)
Connectors
Construction
• All type nylon 66 construction with “O” ring and steel lock nut included.
• Reusable and durable connectors are flame retardant and resist salt water, weak acids, gasoline, alcohol, oil grease, and common solvents.
Installation
• Connectors used with standard non-metallic
Type B conduit for easy installation.
• Approved for both exposed and concealed locations.
Rated for temperature ranges of -
40˚F to +212˚F (-40˚C to +100˚C).
• Easy to install, by pushing the non-metallic conduit onto the smooth ferrule and tightening the sealing nut.
• Manufactured in a full range of trade sizes from 3/8" through 2".
• Complies with NEC Article 356 and UL Standard 514B
File No. E-322120.
• Straight connectors approved for direct burial and in concrete trade sizes 3/8" through 2".
90° Connector NPT 3/8” through 2”
NEC Articles
Straight Connector NPT 3/8 Through 2”
• Article 250.102 Equipment Bonding Jumpers
• Article 250.134 (B) Equipment Grounding
• Article 356 Liquid-Tight Flexible Nonmetallic Conduit
(LFNC-B)
• Article 501.10 (B) (2) Class
I Div. 2
• Article 502.10 (A) (2) and (B) (2) Class
II Div. 1 & 2
• Article 503.10 (A) (3) and (B) Class
III Div. 1 & 2
• Article 620.21 Elevator Wiring Methods
• Article 645.5 (E) (2) Under Raised Floors www.ul.com www.nfpa.org www.nema.org www.csa-international.org www.naed.org www.anametelectrical.com
• UL LISTED • CSA CERTIFIED
Gray nylon 66
Electrical
Trade Size
Inches mm
3/8
3/8
1/2
1/2
3/4
3/4
12
12
16
16
21
21
Product Specifications
K.O. Size
Inches
1/2
1/2
1/2
1/2
3/4
3/4
A
1.545
Dimensions
Inches
B
0.535
C
1.400
2.242
1.545
0.562
0.535
3.120
1.400
2.242
1.600
2.550
0.562
0.550
0.545
3.120
1.700
3.600
1
1
1-1/4
1-1/4
1-1/2
1-1/2
2
2
27
27
35
35
41
41
53
53
1
1
1-1/4
1-1/4
1-1/2
1-1/2
2
2
1.975
3.150
2.293
3.420
2.175
4.510
2.400
4.850
0.670
0.630
0.645
0.645
0.660
0.660
0.670
0.670
2.000
4.125
2.400
5.200
2.670
5.200
3.280
5.800
• RoHS WEEE COMPLIANT
Ordering Information
0.7
0.8
1
1.4
0.6
0.8
0.8
1
Approx
Weight lbs.
PER
Pkg.
1.25
0.5
1.25
0.5
0.7
1
Straight Connectors
Standard
Package
AEI
PIN
25 500001
25 500002
10 500003
5 500004
5 500005
5 500006
2 500007
90° Connectors
Standard
Package
AEI
PIN
10 500008
10 500009
10 500010
5
2
2
1
500011
500012
500013
500014
ANAMET Electrical, Inc.
CAT-NMUAC-130901 25
Anaconda SEALTITE ®
Construction
UL Listed, CSA Certified Nonconductive Conduit
Liquid-Tight Flexible Non-Metallic Conduit (LFNC)
• Constructed of smooth inner thermoplastic PVC core with outer PVC cover bonded together with nylon reinforcing braid.
• Durable, sunlight resistant and flame retardant thermoplastic PVC that resists heat, oil and chemical breakdown.
Nylon Reinforced 3/8" through 2"
NEC Articles
Installation
• Article 250.102 Equipment Bonding Jumpers
• Conduit used with standard connectors for non-metallic conduit Type A for easy installation. IP 66/67 Rated when installed with approved connectors.
• Article 250.134 (B) Equipment Grounding
• Article 300.22 (D) Information Technology Equipment
• Approved for both exposed and concealed locations.
Rated for temperature ranges of 4˚F to +140˚F (-20˚C to +60˚C).
• Article 356 Liquid-Tight Flexible Nonmetallic Conduit
(LFNC-A)
• Article 501.10 (B) (2) Class
I Div. 2
• Complies with UL Standard 1660 Type A conduit File
No. E-75863; CSA C22.2 File No. LL15257; and NEC
Article 356.
• Easy to install and cuts easily.
• Article 502.10 (A) (2) and (B) (2) Class
II Div. 1 & 2
• Article 503.10 (A) (3) and (B) Class
III Div. 1 & 2
• Article 620.21 Elevator Wiring Methods
• Article 645.5 (E) (2) Under Raised Floors
• Manufactured in a full range of trade sizes from 3/8" through 2".
• Flexible, but tough; crush, abrasion and strain resistant.
Where abrasion, physical abuse or constant flexing are a factor.
www.ul.com www.nfpa.org www.nema.org www.csa-international.org www.naed.org www.anametelectrical.com
U.L. LISTED • CSA CERTIFIED • RoHS WEEE COMPLIANT
Orange or Gray thermoplastic PVC
Product Specifications
Electrical
Trade Size
Inches mm
Inside Diameter Outside Diameter
Inches Inches
3/8
1/2
3/4
1
1-1/4
1-1/2
12
16
21
27
35
41
MIN.
MAX.
. 485 – .505
.620 – .640
.815 – .835
1.030 – 1.055
1.370 – 1.395
1.585 – 1.620
2.045 – 2.080
MIN.
MAX.
. 755 – .775
.910 – .930
1.150 – 1.170
1.415 – 1.440
1.800 – 1.825
2.045 – 2.080
2.605 – 2.640
2 53
Note: 1. Colors available on request.
2. Gray, change 3 rd number in NAED code to “8”
Approx
Inside
Bend
Radius
Inches
2.5
3.0
4.0
6.0
7.0
8.0
9.0
Approx
Weight lbs.
PER
100 FT.
15
21
30
43
58
81
122
Ordering Information
Small Carton
Length
Feet
NAED
PIN
100
100
100
38602
38612
38622
Standard Carton
Length
Feet
NAED
PIN
250
200
175
100
50
50
50
38601
38611
38621
38631
38641
38651
38661
Reels
Length
Feet
NAED
PIN
800
500
400
300
200
100
100
38604
38614
38624
38634
38643
38653
38663
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type CNP. Conduit shall be constructed of smooth inner thermoplastic PVC core with outer oil-resistant and sunlight resistant PVC outer cover. Conduit shall have nylon reinforcing layer between the core and outer cover. Conduit shall be assembled with approved fittings to provide liquid-tight raceway for wiring. Conduit shall be UL listed and CSA certified as a T ype “A” non-metallic conduit and be used in applications requiring a temperature range of 4˚F to +140˚F (-20˚C to +60˚C). Conduit IP 66/67 rated when installed with approved end connectors.
26 CAT-CNP-130901
ANAMET Electrical, Inc.
Anaconda SEALTITE ®
EMI/EMP for High Level Shielding
Liquid-Tight Flexible Metal Conduit (LFMC)
Construction
• Constructed of continuously interlocked high shielding bronze core for exceptional shielding effectiveness.
• Durable, abrasion resistant, flame retardant and sunlight resistant smooth thermoplastic PVC jacket that resists oil, heat and chemical breakdown.
Installation
• Conduit used with standard liquid-tight connector for easy installation. IP 66/67 Rated when installed with approved connectors.
• Meets Mil-STD-1310D for EMI and EMP shielding.
• Smooth interior surface protects sensitive conductors from harm.
• Provides shielding effectiveness of 81 – 119 Db at 1
Megahertz to 1 Gigahertz.
• Rated for temperature range from -51˚F to + 221˚F
(46˚C to +105˚C).
• Manufactured in a full range of sizes from 3/8" through 4".
• Available in custom-cut lengths.
Interlocked Design
3/8” through 4” www.anametelectrical.com
• RoHS WEEE COMPLIANT
®
Gray thermoplastic PVC jacket
Electrical
Trade Size
Inches mm
3/8
1/2
3/4
1
1-1/4
1-1/2
2
2-1/2
3
12
16
21
27
35
41
53
63
78
Product Specifications
Inside Diameter Outside Diameter
Inches
MIN.
MAX.
MIN.
Inches
MAX.
.485 – .505
.622 – .642
.815 – .835
1.041 – 1.066
.690
.820
1.030
1.290
– .710
– .840
– 1.050
– 1.315
1.370 – 1.395
1.575 – 1.600
2.020 – 2.045
2.480 – 2.505
3.070 – 3.100
4.000 – 4.040
1.630 – 1.660
1.865 – 1.900
2.340 – 2.375
2.840 – 2.875
3.460
4.460
– 3.500
– 4.500
Approx
Inside
Bend
Radius
Inches
3.0
3.0
4.0
4.0
4.5
7.0
9.5
12
13.5
Ordering Information
Approx
Weight lbs.
PER
100 FT.
24
28
42
56
Part Number
NAED
PIN
450200-0240
450202-0140
450204-0240
450206-0340
75
96
125
165
211
450208-0140
450210-0140
450212-0140
450214-0140
450216-0140
4 103 17 298 450220-0140
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type SHIELDTITE ® . Conduit shall have smooth cover and be constructed with bronze core of high level shielding. Conduit shall meet Mil-STD-1310D for EMI and EMP shielding effectiveness of 81 – 119 Db at 1 Megahertz to 1 Gigahertz. Conduit shall be suitable for use within an operating temperature range of 51˚F to +221˚F (-46˚C to 105˚C).
ANAMET Electrical, Inc.
CAT-SHIELDTITE-130901 27
Anaconda SEALTITE ®
Construction
• Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance.
NSF Certified Component
Liquid-Tight Flexible Metal Conduit (LFMC)
• Flexible thermoplastic PVC jacket formulated for food and beverage applications per FDA CFR 21 and NSF
51 requirements.
Square-Locked Design with integral bonding wire 3/8" through 1-1/4"
• Jacket is easily cleaned and does not promote bacteria growth
Installation
• NSF Certified to NSF/ ANSI 169 for special purpose food equipment or devices.
• Delivers superior wiring protection where incidental food contact is possible.
• Conduit used with standard liquid-tight connector for easy installation. IP 66/67 Rated when installed with approved connectors.
• Suitable for use in restaurants, food processing facilities, poultry packing facilities, meat packing facilities, wash down areas, waste water teatment, pharaceutical applications and on special purpose food equiptment or devices.
• Manufactured in a full range of trade sizes from 3/8" through 2".
• Rated for temperature range of -4°F to +140°F (-20°C to +60°C).
Interlocked Design 1-1/2" through 4" with no bonding wire
Places Of Interest
• Food Equiptment or Devices NSF/ANSI 169
• Food Equipment Manufacturers SIC 3556
• Meat Packing SIC 2011 NAICS 311613
• Poultry SIC 2015 NAICS 311615
• Pharmaceuticals SIC 2834 NAICS 325412 www.fda.gov www.naed.org www.nsf.org www.nema.org www.anametelectrical.com
NSF Component • FDA Approved Compound • RoHS WEEE COMPLIANT
White Thermoplastic PVC jacket no bonding wire
Product Specifications
Electrical
Trade Size
Inches mm
Inside Diameter Outside Diameter
Inches Inches
3/8
1/2
3/4
1
2
1-1/4
1-1/2
12
16
21
27
35
41
53
MIN.
MAX.
.484 – .504
.622 – .642
.820 – .840
1.041 – 1.066
1.380 – 1.410
1.575 – 1.600
2.020 – 2.045
MIN.
MAX.
.690 – .710
.822 – .840
1.030 – 1.050
1.290 – 1.315
1.630 – 1.660
1.865 – 1.900
2.340 – 2.375
Note: 1. Above 2” Available on special order.
2. Other colors available on request.
Approx
Inside
Bend
Radius
Inches
2.0
2.5
3.0
4.0
4.5
5.5
7.0
Approx
Weight lbs.
PER
100 FT.
21
25
39
51
66
104
136
Ordering
Information
Small Carton
Length NAED
Feet PIN
100
100
100
100
50
50
50
35502
35512
35522
35531
35541
35551
35561
Typical Specification
Conduit shall be Anaconda SEALTITE® Type FG. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with PVC outer jacket. Type FG conduit shall be used for applications where incidental food contact is possible. Conduit IP 66/67 rated when installed with approved end connectorsnd connectors.
ANAMET Electrical, Inc.
CAT-FG-130901 29
Anaconda SEALTITE ®
Construction
• Constructed of continuously interlocked hot dipped zinc galvanized steel core for exceptional crush and corrosion resistance.
• Durable, abrasion-resistant, smooth, chlorinated polyethylene jacket that resists heat, oil and chemical breakdown.
Nuclear Wiring Conduit
Liquid-Tight Flexible Metal Conduit (LFMC)
Square-Locked Design with integral bonding wire 3/8" through 1-1/4"
Installation
• Conduit used with standard liquid-tight connector for easy installation. IP 66/67 Rated when installed with approved connectors.
• Suitable for use within nuclear containment areas.
• Flexible metal core meets “Construction” requirements of UL Std. 360 sizes 3/8" through 4".
• Radiation resistant jacket meets IEEE 323-1974 and
IEEE 383-1974 guidelines.
• Rated for temperature range of -40˚F to + 192˚F (-40˚C to +89˚C).
• Manufactured in a full range of sizes from 3/8" through 4".
Interlocked Design 1-1/2" through 4" with no bonding wire
NUCLEAR PROCURMENT ISSUES COMMITTEE
(NUPIC)
NUPIC number 2651 www.nupic.com www.anametelectrical.com
Black chlorinated polyethylene jacket with bonding wire through 1-1/4"
Electrical
Trade Size
Inches mm
3/8
1/2
3/4
1
1-1/4
1-1/2
2
2-1/2
3
4
12
41
53
63
78
103
16
21
27
35
Product Specifications
Inside Diameter Outside Diameter
Inches
MIN.
MAX.
MIN.
Inches
MAX.
.484 – .504
.622 – .642
.820 – .840
1.041 – 1.066
.690
.820
1.030
1.290
– .710
– .840
– 1.050
– 1.315
1.380 – 1.410
1.575 – 1.600
2.020 – 2.045
2.480 – 2.505
3.070 – 3.100
4.000 – 4.040
1.630 – 1.660
1.865 – 1.900
2.340 – 2.375
2.840 – 2.875
3.460
4.460
– 3.500
– 4.500
Approx
Inside
Bend
Radius
Inches
20
22
24
30
36
8.0
9.0
13
15
18
Ordering Information
Approx
Weight lbs.
Standard Carton
PER
100 FT.
Length
Feet
NAED
PIN
25
29
44
73
100
100
100
100
100
50
433999-0143
434009-0143
434019-0143
434029-0143
434039-0143
112
148
182
255
362
50
50
25
25
25
434049-0143
434059-0143
434069-0143
434079-0143
434089-0143
TyPICAL SPECIFICATION:
Conduit shall be Anaconda SEALTITE ® Type NWC. Conduit shall provide a flexible liquid-tight raceway for wiring and shall be constructed of continuously interlocked hot dipped zinc galvanized steel core with an integral bonding wire in sizes 3/8" through 1-1/4". Jacket shall be black in color and be radiation-resistant. The outside of the jacket shall have a smooth appearance, Jacket material shall meet guidelines defined in IEEE 323-1974 and
IEEE 383-1974.
30 CAT-NWC-130901
ANAMET Electrical, Inc.
Anaconda SEALTITE ®
Square Lock
Stainless Steel Stripwound Hose
Construction
• Constructed of continuously interlocked Type 302 stainless steel core for exceptional crush and corrosion resistance.
• Extruded PVC, Silicone, Teflon, and Thermoplastic
Rubber jackets available upon request.
• Available in brass, galvanized steel and aluminum.
Square Lock Construction
Applications
• Fiber Optics
• Instrumentation
• Sensors
• Recording Instruments
• Temperature Measuring Devices www.nema.org www.naed.org
www.anametelectrical.com
• RoHS WEEE COMPLIANT
Stainless Steel Stripwound Hose
Product Specifications
Nominal Size
Inches
1/8
5/32
3/16
7/32
1/4
9/32
5/16 mm
3
4
5
5.6
6.3
7
8
Inside Diameter Outside Diameter
Inches Inches
MIN.
MAX.
MIN.
MAX.
.125-.137
.152-.164
.195-.207
.232-.244
.183-.195
.206-.221
.245-.260
.276-.291
.302-.317
.263-.275
.291-.306
.330-.345
.361-.376
.412-.427
3/8
1/2
9
13
.363-.383
.483-.503
.473-.493
.603-.623
5/8 15 .605-.625
.735-.755
NOTE: 1. Other sizes available on special order.
2. Available in brass, galvanized steel and aluminum.
Approx
Inside
Bend
Radius
Inches
1
1
1
1
1-1/4
1-1/4
1-1/4
1-1/2
1-1/2
2
Approx
Weight lbs.
PER
100 FT.
2.3
3.4
3.7
4.1
4.8
5.4
6.7
7.9
10.8
12.2
Ordering
Information
Standard Reel
Length NAED
Feet PIN
1000
1000
460610-0070
460613-0070
1000
1000
800
600
500
460615-0074
460619-0070
460622-0074
460625-0070
460628-0070
275
250
250
460634-0074
460643-0070
460652-0070
ANAMET Electrical, Inc.
CAT-SL-130901 31
Anaconda SEALTITE ®
Capillary Armor
Stainless Steel Stripwound Hose
Construction
• Constructed of continuously interlocked Type 302 stainless steel core for exceptional crush and corrosion resistance.
• Product will not spring open or unwind.
• Extruded PVC, Silicone, Teflon, and Thermoplastic
Rubber jackets available upon request.
• Available in brass, galvanized steel and aluminum.
Applications
• For applications with a max temperature of 1800°F
• Casings
• Armor
• Protection for wiring and capillary tubing
• Control cables
• Bar Dispenser casing
Interlocked Construction www.naed.org www.nema.org
www.anametelectrical.com
• RoHS WEEE COMPLIANT
Stainless Steel Stripwound Hose
Product Specifications
Nominal Size
Inches mm
5/32
3/16
7/32
4
5
5.5
Inside Diameter Outside Diameter
Inches
MIN.
MAX.
MIN.
Inches
MAX.
.160-.175
.180-.195
.215-.230
.255-.270
.275-.290
.310-.325
1/4
5/16
3/8
7/16
6
8
9.5
11
.245-.260
.310-.325
.370-.390
.432-.452
.340-.355
.405-.420
.485-.505
.547-.567
1/2 12.7
.495-.515
.610-.630
NOTE: 1. Other sizes available on special order.
2. Available in brass, galvanized steel and aluminum.
Approx
Inside
Bend
Radius
Inches
1-1/2
1-1/2
1-1/2
1-1/2
1-1/2
2
2-1/2
2-1/2
Approx
Weight lbs.
PER
100 FT.
4.2
4.9
6.6
7.3
8.9
12
14.7
16.5
Ordering
Information
Standard Reel
Length
Feet
NAED
PIN
1000
1000
1500
451550-0070
451554-0070
451560-0070
800
500
500
500
500
451564-0070
451568-0070
451572-0070
451574-0070
451576-0070
32 CAT -UI-130901
ANAMET Electrical, Inc.
Anaconda SEALTITE ®
Standard coils of Anaconda SEALTITE ® are packaged in handy, strong, corrugated cartons. These cartons keep stock clean and are easy to handle, stack and identify. Size, type, color and footage are prominently displayed on the side of each carton. A handy cutting instruction card is included in each carton.
Smaller coils of Anaconda SEALTITE ® types EF, EFST and UA are also packaged in corrugated cartons with the same features as the standard coil cartons mentioned above. Smaller coils provide the same convenience as standard coils —the shorter length allow for more economical purchasing on the smaller jobs.
Non-returnable Standard and
Small Wooden Reels
Anaconda SEALTITE ® is available on non- returnable wooden reels at no extra cost.
Continuous lengths on reels eliminates scrap and special handling.
For those who like the convenience of reels, but do not require the longer footages on the standard reels, Anamet offers smaller reels with less continuous footage on types
EF, EFST, CW, UA and ZHUA conduit.
Electrical
Trade Size
(Inches)
Standard
3/8 and 1/2
3/4
1 and 1-1/4
Small
3/8, 1/2, 3/4
1-1/2 & 2
Flange
(Inches)
Reel
30
36
30
Reel
30
Traverse*
(Inches)
Dimensions
18
26
22
Dimensions
17
*Measurement Between Flanges
Core
Diameter
(Inches)
10
20
14-1/2
14-1/2
Large Reels Available on Special Request
Center
Hole
(Inches)
1-1/2
1-1/2
1-1/2
1-1/2
Hand Cutting SEALTITE ® with Metallic Core
Importance of clean, square cut:
• Easier connector attachment.
• Conduit makes full contact with base of liquid-tight connector.
• Gives greater holding power to connector.
• Assures a liquid-tight assembly throughout.
Non-metallic SEALTITE ®
• Square, clean cuts are important for effective assembly with electrical connectors. Conduit is marked at 12" intervals for easy measuring.
• Type CNP conduit can be cut most easily with a sharpened “parrot nosed” electrical cable slicer.
• Good clean cuts can also be made with a sharp shoe knife. A little liquid detergent used to “wet” the knife blade will reduce frictional drag appreciably.
• Cutting the non-metallic conduit with a saw is not recommended.
Production Cutting SEALTITE ®
Using a Band Saw
When cutting Anaconda SEALTITE ® with a band saw, the recommended blade specifications are: 1/2" wide x .025" thick, having 24 teeth per inch, no set. Blade speed should be approximately 350 ft. per minute. Band Saw cutting is recommended when extensive cutting Is required. Do NOT use abrasive wheel.
Custom Cut Lengths
• Size range 1/8" to 2"
• Bare hose (DE-710, DSL RWA, RWS, SL, UI)
• Covered hose (SEALTITE®)
• Lengths up to 12 feet
Quotations available upon request.
ANAMET Electrical, Inc.
CAT-PKC-130901 33
Anaconda SEALTITE ®
The listed chemicals have been tested with results noted below. It is recommended that samples of conduit should be tested under actual conditions wherever possible, since results may differ from test conditions.
1- Excellent
Continuous Service
Chemical
Acetate Solvents
Acetic Acid
Acetic Acid (Glacial)
Acetone
Acrylonitrile
Alcohols (Aliphatic)
Aluminum Chloride
Aluminum Sulfate (Alums)
Ammonia (Anhydrous Liquids)
Ammonia (Aqueous)
Ammoniated Latex
Ammonium Chloride
Ammonium Hydroxide
Amyl Acetate
Aniline Oils
Aromatic Hydrocarbons
Asphalt
ASTM Fuel A
ASTM Fuel B
ASTM # 1 Oil
ASTM # 3 Oil
Barium Chloride
Barium Sulfide
Barium Hydroxide
Benzene (Benzol)
Benzine (Petroleum Ether)
Black Liquor
Bordeaux Mixture
Boric Acid
Butyl Acetate
Butyl Alcohol
Calcium Hydroxide
Calcium Hypochlorite
Carbolic Acid (Phenol)
Carbon Dioxide
Carbon Disulfide
Carbon Tetrachloride
Carbonic Acid
Casein
Caustic Soda
Chlorine Gas (wet)
Chlorine Gas (dry)
Chlorine (water solution)
Chlorobenzene
Chlorinated Hydrocarbons
34
2- Good
Intermittent Service
3- Fair
Limited Service Life
4- Poor
Do not use
Jacket Material
% TPR TPU PVC
10 2
4
2 4
4
2
3
4
1
10
10
2
2
2
2
4
2
2
4
1
1
1
4
4
3
1
1
4
1
4
4
4
2
2
2
4
4
3
4
2
4
4
2
4
3
1
1
1
4
4
4
2
4
3
1
1
1
4
2
4
2
4
4 2
1
1
2
1
10
4
1
4
4
1
1
1 2
2
2
4 4
4
4
3
4
4
CAT-CRC1-130901
Chromic Acid
Chemical
Citric Acid
Coal Tar
Coconut Oil
Corn Oil
Cottonseed Oil
Creosote
Cresol
Cresylic Acid
Cyclohexane
DDT Weed Killer
Dibutyl Phthalate
Diesel Oils
Diethylene Glycol
Diethyl Ether
Di-isodecyl Phthalate
Dioctyl Phthalate
Dow General Weed Killer (Phenol)
Dow General Weed Killer (H2O)
Ethyl Alcohol
Ethylene Dichloride
Ethylene Glycol
Ferric Chloride
Ferric Sulfate
Ferrous Chloride
Ferrous Sulfate
Formaldehyde
Fuel Oil
Furfural
Gallic Acid
Gasoline (Hi Test)
Glycerine
Grease
Green Sulfate Liquor
Heptachlor in Petroleum Solvents
Heptane
Hexane
Hydrobromic Acid
Hydrochloric Acid
Hydrochloric Acid
Hydrochloric Acid
Hydrofluorobonic Acid
Hydrofluorosilicic Acid
Hydrogen Peroxide
Iso-octane
ANAMET Electrical, Inc.
Jacket Material
% TPR TPU PVC
10 2 4
2
2
1
4
3
1
4
4
3
4
3
4
2
4
4
4
2
1
1
4
3
2
1
1
4
4
4
4
4
2
3
50
10
2
2
4
2
1
1
1
1
1
2
1
1
4
4
4
2
4
1
1
1
4
2
3
1
3
1
1
1
1
10
40
70
10
4
4
2
2
4
2
4
2
2
1
1
4
1
1
1
3
3
3
1
1
3
Anaconda SEALTITE ®
The listed chemicals have been tested with results noted below. It is recommended that samples of conduit should be tested under actual conditions wherever possible, since results may differ from test conditions.
1- Excellent
Continuous Service
Chemical
Isopropyl Acetate
Isopropyl Alcohol
Jet Fuels (JP-3,4 and 5)
Kerosene
Ketones
Linseed Oil
Lubricating Oils
Magnesium Chloride
Magnesium Hydroxide
Magnesium Sulfate
Malathion 50 in Aromatics
Malic Acid
Methyl Acetate
Methyl Alcohol
Methyl Bromide
Methyl Ethyl Ketone
Methylene Chloride
Mineral Oil
Monochlorobenzne
Muriatic Acid (See Hydrochloric
Acid)
Naphtha
Naphthalene
Nitric Acid
Nitric Acid
Nitric Acid
Oleic Acid
Oleum
Oxalic Acid
Pentachlorophenol in Oil
Pentane
Perchloroethylene
Petroleum Ether
Phenol
Phosphoric Acid
Pitch
Potassium Hydroxide
Propyl Alcohol
Ritchfield “A” Weed Killer
Sea Water
Sodium Hydroxide
Sodium Hydroxide
Soybean Oil
Sodium Cyanide
Stoddard Solvent
Styrene
ANAMET Electrical, Inc.
2- Good
Intermittent Service
3- Fair
Limited Service Life
4
4
2
2
4
1
4
4
4
4
2
2
2
1
1
10
35
70
85
10
50
Jacket Material
% TPR TPU PVC
4
4 1 2
30
4
4
4
1
2
2
3
3
4
1
1
1
1
1
1
4 4
4
4
4
2
4
4
2
4
4
1
4
4
1
4
3
4
-
1
4
4
4
1
2
4
3
4
1
1
4
1
4
1
2
3
4
3
2
1
2
1
2
3
1
1
1
3
1
4
4
CAT-CRC2-130901
Chemical
Sulfur Dioxide (Liquid)
Sulfuric Acid
Sulfuric Acid
Sulfurous Acid
Tall Oil
Tannic Acid
Toluene
Trichlorethylene
Triethanol Amine
Tricresyl Phosphate (Skydrol)
Turpentine
Vinegar
Vinyl Chloride
Water
White Liquor
Xylene
Zinc Chloride
Zinc Sulfate
4- Poor
Do not use
Jacket Material
% TPR TPU PVC
4 4
50 1 2 1
98
10
2
1
1
4
4 4
4
4
4
2
4
1
4
4
3
4
4 2
1
3
1
4
1
1
1
4
2
2
4
1
1
35
Anaconda SEALTITE ®
34 CAT-CRC1-130901
ANAMET Electrical, Inc.