Wedge LED Specsheet - Inter-Lux

advertisement
Wedge LED Specifications
Send
Ordering Information
2537
Type
Length
Model
Type
2537
S
P2C
P3C
P4C
P2R
P3R
P4R
Voltage
Options
Power Supplies
Color
Voltage
Power4
Shielding Options
27
30
35
40
UNV
S
D010
D3W
DES
SD
LED
Color
Length
LED
Specify
length
L
M
H
2
3
Luminaire
3.3"
[83mm]
n
UNV = 120-277V
n
120 = 120V
n
White LED light source.
Power Supply4
n
Lengths and angles factory cut to exact
field dimensions.
n
S = Standard non-dim driver, 120-277V,
96W
n
Powder coat painted white - RAL 9010.
n
D010 = Osram, 10%, 0-10V dimming,
120-277V, 96W
n
D3W = Lutron, 1%, 3-wire fluorescent
dimming, 120-277V, 40W
n
DES = Lutron, 1%, EcoSystem E1/E2
digital dimming, 120-277V, 40W
n
DFPN = Lutron 1% forward phase with
neutral, 120V only, 40W
Type1
Straight
Patterns
n
S = Straight run
n
P2C = 2 sided inside corner
n
P3C = 3 sided inside corner
n
P4C = 4 sided inside corner
n
P2R = 2 sided outside corner
n
P3R = 3 sided outside corner
Shielding
n
P4R = 4 sided outside corner
n
Length2
n
2 sided
Specify feet & inches to the nearest
1/8”. e.g. 8’-0”, 8’-1 1/8”
LED (single row)
3 sided
n
L = Low Power (3W/ft)
n
M = Mid Power (6W/ft)
n
H = High Power (10W/ft)
Color3 (low/mid/high)
4 sided
Voltage
Indirect very small scale wall mounted
uplight featuring precision knife edge for
clean, minimal effect.
n
1.7"
[43mm]
DFPN
120V
n
27 = 2700K, 265/561/863 lm/ft
n
30 = 3000K, 287/613/949 lm/ft
n
35 = 3500K, 315/674/1044 lm/ft
n
40 = 4000K, 325/699/1072 lm/ft
SD = Satin flat lens
Options
n
1
Contact factory for emergency lighting
options
Patterns to include corners.
To specify length add sum of each mounting
surface.
3
Nominal values shown, see photometry for
actual values.
4
Remote power supply required. See power
supply page for details.
2
410 381 1497 inter-lux.com answers@inter-lux.com
Inter-lux reserves the right to make technical changes without notice.
(rev 0)
1
Wedge LED Patterns
wall
wall
wall
Inside Corners
wall
wall
wall
wall
wall
wall
P4C - 4 sided inside
wall
P3C - 3 sided inside
wall
P2C - 2 sided inside
nose
wall
wall
nose
wall
nose
wall
wall
wall
nose
nose
nose
nose
wall
nose
Outside Corners
P3R - 3 sided outside
wall
wall
wall
wall
wall
wall
wall
wall
P4R - 4 sided outside
wall
wall
P2R - 2 sided outside
wall
wall
wall
nose
wall
nose
wall
nose
wall
wall
wall
Corners Details
nose
nose
nose
12”
wall
nose
nose
wall
nose
outside corner
wall
90º
12”
12”
slot
wall
top view
slot
inside corner
nose
90º
12”
top view
410 381 1497 inter-lux.com answers@inter-lux.com
Inter-lux reserves the right to make technical changes without notice.
2
Wedge LED Ends and Corners
Power Feed to Remote driver
96W 120/277 0-10V
Dimmable Driver
40.0"
[1016mm]
Mounting Point Typ.
Plastic anchors with # 8 wood screw
or toggle bolt with screw or blocking
as required (By Others)
40.0"
[1016mm]
Mounting Point Typ.
36.0"
[914mm]
Mounting Point End
36.0"
[914mm]
Mounting Point End
Line of Finished Wall
Clear Acrylic Cover
LED Location
Light Body
Suppplied
Extruded Body
Power Feed (by others) to Remote driver
96W 120/277 0-10V
Dimmable Driver
1.7"
[43mm]
3.3"
[83mm]
410 381 1497 inter-lux.com answers@inter-lux.com
Inter-lux reserves the right to make technical changes without notice.
3
Wedge LED Power Supplies
Wiring Diagrams
D010 (Osram 0-10V)
Black (L)
White (N)
Black
Black
(L)(L)
Black (L)
(+)
Power Supply
(+)(+)
(-)
White
White
(N)(N)
Power
Power
Supply
Supply
Gray (-)
Purple
Purple
(+)(+)
(-) (-)
Ground (Green)
Ground
Ground
(Green)
(Green)
(-) (-)
®
Wiring(Lutron
Diagram for1%
EcoSystem®
Digital Control
DES
EcoSystem
digital)
Switched
Hot
(Black)
Wiring
Wiring
Diagram
Diagram
for
for
EcoSystem®
EcoSystem®
Digital
Digital
Control
Control
Wiring
Wiring
Diagram
Diagram
forfor
3-Wire
3-Wire
Control
Control
Switched Hot (Black)
+V
LED light
Hi-lume®
+V+V engine
A-Series
light
light -V
Hi-lume®
Hi-lume® LEDLED
engine
A-Series
A-Series engine
Ground
Ground
Ground
(+)(+)
(-)
light
LEDLED
light
engine
engine
Wiring (Lutron
Diagram for1%,
3-Wire
Control
D3W
3-wire)
To 3-wire Dimming Control
ToDimming
3-wire Dimming
To 3-wire
Control Control
To Forward Phase Control
To Forward
Phase Control
To Forward
Phase Control
Wiring
Wiring
Diagram
Diagram
forfor
Forward
Forward
Phase
Phase
Control
Control
Neutral
Neutral
(White)
(White)
Power
Power
Supply
Supply
Gray
Gray
(-) (-)
Wiring Diagram
for Forward
Phase Control
DFPN
(1% Lutron
forward
phase with neutral)
Neutral (White)
Dimmed
Dimmed
HotHot
(Black)
(Black)
Power Supply
Purple
(+)
White
White
(N)
(N)
LEDLED
light
light
engine
engine
Dimmed Hot (Black)
(+)
White (N)
Black
Black
(L)(L)
-V -V
Note: Colors shown correspond to terminal blocks on driver.
+V
Dimmed Hot (Orange)
Switched
Switched
HotHot
(Black)
(Black)
LED light
Hi-lume®
+V+V engine
A-Series
Neutral (White)
Dimmed
Dimmed
HotHot
(Orange)
(Orange) Hi-lume®
light
light-V
Hi-lume® LEDLED
engine
A-Series
A-Series engine
Ground (Green)
Neutral
Neutral
(White)
(White)
-V -V
Ground
Ground
Ground
(Green)
(Green)
Ground
Ground
Note: Colors shown correspond to terminal blocks on driver.
To EcoSystem®
To Line To Line
To EcoSystem®
Link
ToDigital
EcoSystem®
Voltage
To Line Voltage
Digital Link
Digital Link
Voltage
S (Standard non-dim)
Neutral (White)
Switched
Switched
HotHot
(Black)
(Black)
Ground (Green)
Neutral
Neutral
(White)
(White)
Ground
Ground
(Green)
(Green)
E1 (Purple)
+V
LED light
Hi-lume®
+V+V engine
A-Series
light
light
Hi-lume®
Hi-lume® LEDLED
-V
engine
A-Series
A-Series engine
-V -V
Ground
Ground
Ground
E2
E2
(Purple)
(Purple)
Note: Colors shown correspond to terminal blocks on driver.
Note:
Note:
Colors
Colors
shown
shown
correspond
correspond
to terminal
to terminal
blocks
blocks
on on
driver.
driver.
E1
(Purple)
(Purple)
E2E1
(Purple)
Note:
Note:
Colors
Colors
shown
shown
correspond
correspond
to terminal
to terminal
blocks
blocks
on on
driver.
driver.
Wiring Notes
1. Quantity of drivers varies with length of run and LED power level.
2. Extend wire from power supply enclosure to Mini Edgeless fixture as required
by the LED wattage and power supply capacity.
3. Refer to maximum wire distance chart below for additional wiring requirements.
Standard enclosure supplied with drivers shown above.
Maximum wiring distance*
Load per driver
Osram
2.0”
*
Lutron
Wire gauge
≤48W
≤72W
≤96W
#18AWG
37’
25’
18’
≤40W
15’
#16AWG
59’
39’
29’
25’
#14AWG
95’
63’
47’
40’
#12AWG
151’
101’
75’
60’
#10AWG
241’
160’
120’
—
Voltage drop guide for 24VDC. Actual Voltage drop
to be calculated by installer
14”
3.0”
410 381 1497 inter-lux.com answers@inter-lux.com
Inter-lux reserves the right to make technical changes without notice.
4
Download