I N S T A L L A T I O N 0563 / 0563LM 0 Series SURFACE MOUNTED RIM STRIKE ® Installations of this RIM strike, qualify as “Indoor Use Only”, when not continuously exposed to an outdoor environment. Important: • Ensure the listed exit device functions as intended for life safety concerns by verifying electric strike and exit device compatibility. • Maximum latch projection is essential to obtain full holding force. Use 1/8" spacers to maximize latch contact. • The strike and all devices connected to it, shall be installed with wires less than 30m in length. • When installed in a Fail Locked manner, the local Authority Having Jurisdiction shall be consulted with regards to the use of selected panic hardware to ensure emergency exit from the secured area. Catalog Specifications Model Mode Voltage Duty average Current 0563 Fail Locked/Fail Unlocked 12.7-24VDC Auto-Sensing Continuous 0.03Amp* DC = Direct Current *0.550 Amp peak Instructions Typical Fail Locked Application 1. Carefully prepare the frame per Template T0563. 2. Test fit electric strike to ensure full latch engagement. Add provided spacers, if required. 12/24VDC POWER SUPPLY 3. Set Fail Locked (FL) or Fail Unlocked (FUL) mode using the dip switch identified on the strike. Factory set to Fail Locked. NOTE: Strike must be cycled once for change to take effect. BLACK (-) (+) RED 4a.Make wire connections from the power source to the wire harness supplied. WIRE HARNESS MUST NOT BE CUT * 4b.Make wire connection for monitoring latch (0563LM only). Black: Common Blue: Normally Closed (NC)* Orange: Normally Open (NO)* *with door open SPDT Switch: 1A resistive 24VDC LATCH MONITOR WIRES IN DOOR OPEN STATE ORANGE (NO) BLACK (C) BLACK (-) RED (+) C NO BLUE (NC) NC 0563 (LM) STRIKE KEYPAD / READER * Please contact RCI for proper wiring support if these wires are cut IS0563 © 2014 Rutherford Controls Int’l | A DORMA Group Company www.rutherfordcontrols.com • Phone: 1.800.265.6630 • Fax: 1.800.482.9795 • E-mail: sales@rutherfordcontrols.com PCN14075 R11/14GR-2 Dimensional Details 5. Mount the electric strike with 1/4-20 UNC screws provided in the horizontal adjustment mounting holes (the outer slots). Adjust electric strike horizontally until exit device latch fully engages with the door closed. 1-3/4" (45mm) 1/2" (13mm) NOTE: Ensure a 1/16" (1.5mm) clearance between exit device latch and the electric strike keeper is maintained. Failing to do so will preload the strike and in turn, will not allow the strike to release the door when energized. WARNING: For proper operation a minimum gap of 1/8" (3.2mm) is required between latch and back of strike. If gap is less than 1/8” (3.2mm), the latch will jam and the keeper won’t rotate. 9" (230mm) 1-5/8" (42mm) 8-1/4" (210mm) 1/8" (3.2mm) MINIMUM 5-9/16" (141mm) 1/16" (1.5mm) EXIT DEVICE LATCH Horizontal Adjustment Mounting Holes STRIKE KEEPER FRAME BACK OF STRIKE 6. Tighten the two mounting screws and check operation. Adjust the horizontal position of electric strike as required. Lock Down Holes 7. Use the electric strike as a template to mark the two lock down holes. Remove strike. Drill & tap for 1/4-20 UNC locking screws. Using the 1/4-20 UNC screws provided, secure the electric strike through the lock down holes. 1/4-20 UNC (2 PLACES) MOUNTING SCREW (2 PLACES) 3/4" (19mm) WIRE ACCESS HOLE(S) * * ø3/4" (19mm) WIRE ACCESS HOLE(S) 1/4-20 UNC (2 PLACES) DOOR FRAME STOP DOOR FRAME MOUNTING SCREW (2 PLACES) DOOR FRAME STOP *Second wire access hole required for 0563LM model only. NOTE: Not to scale. Specifications are subject to change without notice. ©2014 Rutherford controls INT’L | A DORMA GROUP COMPANY www.rutherfordcontrols.coM • PHONE : 1.800.265.6630 • FAX: 1.800.482.9795 • e-mail: sales@rutherfordcontrols.com LOCKDOWN SCREW (2 PLACES)